Spelling suggestions: "subject:"marginal aadaptation (dentistry)"" "subject:"marginal aadaptation (sentistry)""
1 |
Evaluation of the DIAGNOdent method for detection and quantification of carious lesions : in vitro and in vivo studies /Bamzahim, Mohammad Shaikh, January 2005 (has links)
Diss. (sammanfattning) Stockholm : Karol. inst., 2005. / Härtill 4 uppsatser.
|
2 |
Calcium aluminate cement as dental restorative : mechanical properties and clinical durability /Sunnegårdh-Grönberg, Karin, January 2004 (has links)
Diss. (sammanfattning) Umeå : Univ., 2004. / Härtill 5 uppsatser.
|
3 |
Influence of the type of post and core on in vitro marginal continuity, fracture resistance, and fracture mode of lithia disilicate-based all-ceramic crowns /Forberger Virag, Nicole. January 2009 (has links)
Diss. med. dent. Zürich (kein Austausch). / Sonderdruck aus: Journal of Prosthetic Dentistry. Vol. 100, no. 4, pp. 264-273, 2008. Literaturverz.
|
4 |
Comparação da desadaptação marginal de infra-estruturas metálicas obtidas com variações na técnica de fundição, revestimentos e material para obtenção dos padrões /Zequetto, Michele Marques. January 2005 (has links)
Orientador: Eulália Maria Martins da Silva / Banca: Wirley Gonçalves Assunção / Banca: Maria da Glória Chiarello de Mattos / Resumo: O presente trabalho avaliou a desadaptação marginal de infra-estruturas metálicas de coroas metalo-cerâmicas obtidas com técnicas de fundição convencional (T1) e rápida (T2), utilizando para inclusão os revestimentos: aglutinado por fosfato Termocast (R1) e a base de cerâmica granulada Micro Fine 1700 (R2), confeccionando padrões em cera escultura Galileo (P1) e padrões em resina acrílica Duralay (P2), com n=56, sobre um troquel metálico. Para a construção dos padrões, utilizou-se uma matriz de silicone e realizou-se a fundição com liga de Ni-Cr. Verificou-se a desadaptação marginal por meio de um microscópio comparador digital Mitutoyo em 12 diferentes pontos de cada infra-estrutura. Os dados obtidos foram submetidos à análise de variância (ANOVA) e teste de Tukey com p<0.05, demonstrando os menores valores de desadaptação marginal e, estatisticamente similares (p<0.05), em ordem crescente, para os grupos: P2R2T2 (55,4æm), P2R1T2 (55,6æm), P2R1T1 (57,4æm), P1R2T2 (59,4æm), P1R2T1 (86æm), P1R1T1(104,4æm); e os maiores valores para P1R1T2 (166,9æm) e P2R2T1 (185,3æm). Os resultados obtidos permitiram concluir que as infra-estruturas metálicas obtidas com padrões, tanto de cera quanto de resina acrílica, apresentaram valores aceitáveis em ambas as técnicas de fundição realizadas, desde que as interações e recomendações dos fabricantes dos revestimentos sejam respeitadas. / Abstract: The present study evaluated the marginal unfit of metallic infrastructures of metallic-ceramic crowns obtained through the conventional (T1) and accelerated (T2) casting techniques, using for investing the investments: agglutinated by phosphate Termocast (R1) and the base of granulated ceramic Micro Fine 1700 (R2), making patterns in sculpture wax Galileo (P1) and patterns in acrylic resin Duralay (P2), with n=56, on a metallic die with shoulder in chamfer. For the construction of the patterns, a matrix of silicone was used and the casting was made with Ni-Cr alloy. The marginal unfit was verified through the comparing microscope Mitutoyo in 12 different points of each infrastructure. The values obtained were submitted to analysis of variance (ANOVA) and Tukeys test with p<0.05, showed smaller values and statistically similar, in increasing order, for the groups: P2R2T2 (55,4ìm), P2R1T2 (55,6ìm), P2R1T1 (57,4ìm), P1R2T2 (59,4ìm), P1R2T1 (86ìm), P1R1T1(104,4ìm); and the largest values for P1R1T2 (166,9ìm) and P2R2T1 (185,3ìm). Taking obtained results into account, it was possible to conclude that the metallic infrastructures obtained from patterns, of wax as well as of acrylic resin, presented acceptable values of marginal fit in both casting techniques, providing the interactions and the recommendations of the investments manufacturers are respected. / Mestre
|
5 |
Avaliação da desadaptação marginal de estruturas metálicas obtidas com variações quanto aos tipos de cera e às técnicas de inclusão e fundição /Marchiori, André Vinícius. January 2004 (has links)
Orientador: Eulália Maria Martins da Silva / Resumo: O objetivo deste trabalho foi observar o comportamento de ceras para fundições, utilizando a técnica de fundição convencional, comparando-a a técnica de fundição rápida; utilizando em ambas a expansão higroscópica de um revestimento fosfatado (All Therm, CNG Soluções Protéticas). Utilizamos duas ceras: Cera para imersão GALILEO Dip Pot Wax (Talladium Inc.) e Cera Azul para fresagem (CNG Soluções Protéticas), que foram submetidas às duas técnicas de fundição propostas. Cada grupo experimental foi composto por 12 corpos de prova e, a verificação do desajuste marginal foi realizada através de um microscópio comparador digital Mitutoyo. Cada corpo de prova foi medido em quatro pontos pré-determinados no troquel metálico. A análise dos resultados demonstrou que, com a metodologia empregada, a técnica de fundição rápida apresentou desempenho favorável, quando comparado com a técnica convencional para ambas as ceras; e a cera Azul para fresagem, na técnica rápida, foi a que apresentou menor valor médio de desadaptação (sub-adaptação). Concluímos que utilizar a expansão higroscópica do revestimento fosfatado foi uma forma de viabilizar a técnica de fundição rápida, obtendo resultados favoráveis com ambas as ceras. / Abstract: The purpose of this investigation was to observe and evaluate the behavior of dental casting wax in conventional and accelerated casting techniques, both using hygroscopic expansion of phosphate bonded investment, in order to determine which material or technique would provide better results about cervical fitting in the obtained metallic structure. The two casting waxes used, GALILEO Dip Pot Wax (Talladium Inc.) and Blue Wax of milling (CNG Soluções Protéticas), were submitted to both proposed casting techniques. Each experimental group was consisted of twelve specimens and, the assessment of marginal fitting was performed by means of a Mitutoyo comparator microscope. Each specimen was measured by using four pre-established points in stainless steel master die as references. From the employed methodology the analysis of the results showed that accelerated casting technique presented superior fitting in comparison with the conventional technique for both types of waxes. Besides, in the accelerated casting technique the Blue Wax of milling presented smaller mean value of unadaptation (underadaptation). We conclude that the use of the hygroscopic expansion of phosphate bonded investment was a way to viable the accelerated casting technique, obtaining favorable results with both casting waxes. / Mestre
|
6 |
Effect of Gap Geometry on Secondary Caries in VitroNassar, Hani M. January 2009 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / Objective: To investigate the effect of the size of the space between the restoration and the dentinal wall of the tooth (i.e. the dentinal portion of the gap) on the development of secondary caries. Methods: Tooth-resin-matrix composite specimens were mounted on custom-made gap-model stages. Specimens were divided into four groups (n=10). Group 1 had a uniform gap size of 30μm throughout both enamel and dentin. Group 2 had a 30μm enamel gap size with a 530μm dentinal gap. Group 3 had 525μm gaps in both enamel and dentin. Group 4 had 525μm and 1025μm gaps in enamel and dentin, respectively. Specimens were attached to plastic Petri plates, gas-sterilized and then incubated in a microbial caries model with S. mutans TH16 in (1% sucrose tryptic soy broth for 1 h, 4 times/day, and with a buffer solution for the rest of the day). After 8 days of incubation, tooth specimens were sectioned and stained with a rhodamine B solution. Digital images were taken under a confocal microscope and analyzed for lesion size at the enamel outer lesion (EOL), enamel wall lesion (EWL), dentin wall lesion next to the DEJ (DWL-A) and dentin wall lesion at 750µm from the DEJ (DWL-B). Results: No difference in EOL size was found between the groups. DWL-A and -B were larger in group 3 than groups 1and 2. Larger DWL-B was found in group 3 than group 4. Group 4 had marginally significant larger EWL than groups 1 and 2 (p=0.0652 and p=0.0648, respectively). Also, group 4 had marginally significant (p=0.0607) larger DWL-B than group 1. Conclusions: Based on the results of this study, it can be concluded that the presence of additional space at the dentinal wall area did not affect secondary caries development as long as the enamel gap was small. However, with enamel gaps of ≈500 µm, the presence of the additional gap space at the dentinal wall led to the development of smaller dentinal wall lesions at the deeper parts of the simulated cavity. Also, in uniform gaps, the size of the interface was positively correlated with size of the dentinal wall lesions.
|
7 |
Efeito da concentração do líquido especial e da temperatura do molde de revestimentos na desadaptação marginal de coroas fundidas em titânioRocha, Sicknan Soares da [UNESP] 08 July 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0
Previous issue date: 2005-07-08Bitstream added on 2014-06-13T18:45:58Z : No. of bitstreams: 1
rocha_ss_dr_arafo.pdf: 430614 bytes, checksum: 1571700915ba54139efb728fbcc0dc8e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo deste estudo foi avaliar o efeito da concentração do líquido especial e da temperatura do molde dos revestimentos Rematitan Plus, específico para titânio, Rema Exakt e Castorit Super C, alternativos, na desadaptação marginal de coroas fundidas em titânio puro. Para o revestimento Rematitan Plus os padrões de cera foram incluídos à vácuo com três diferentes concentrações do líquido especial, 100%, 75% e 50%, diluídos em água destilada. As fundições foram realizadas na máquina Discovery Plasma com os moldes em três temperaturas, 430ºC, 515ºC e 600ºC. Os revestimentos alternativos foram empregados nas condições em que obtiveram expansão total de 0,8%, equivalente à do Rematitan Plus (100%/430ºC), adotado como grupo controle. Conforme as curvas de expansão de presa e térmica foram estabelecidas as condições de concentração e temperatura: Rema Exakt (100%/220ºC, 75%/240ºC e 50%/340ºC) e Castorit Super C (100%/temperatura ambiente e 75%/160ºC). / This study had the goal of assessing the effect of the concentration of the special liquid and the temperature of the mold of Rematitan Plus investment, specific for titanium, Rema Exakt and Castorit Super C, alternative investments, on the marginal misfit of crowns cast on pure titanium. For the Rematitan Plus investment, the wax standards were included in vacuum with three different concentrations of the special liquid, 100%, 75% and 50%, diluted in distilled water. The castings were performed on the Discovery Plasma machine with the molds at three temperatures, 430ºC, 515ºC and 600ºC. The alternative investments were employed under conditions in which they obtained a overall expansion of 0.8%, equivalent to that of the Rematitan Plus (100%/430ºC), adopted as the control group. According to the thermal and setting expansion curves the conditions of concentration and temperature were established: Rema Exakt (100%/220ºC, 75%/240ºC and 50%/340ºC) and Castorit Super C (100%/room temperature and 75%/160ºC).
|
8 |
Efeito da concentração do líquido especial e da temperatura do molde de revestimentos na desadaptação marginal de coroas fundidas em titânio /Rocha, Sicknan Soares da. January 2005 (has links)
Resumo: O objetivo deste estudo foi avaliar o efeito da concentração do líquido especial e da temperatura do molde dos revestimentos Rematitan Plus, específico para titânio, Rema Exakt e Castorit Super C, alternativos, na desadaptação marginal de coroas fundidas em titânio puro. Para o revestimento Rematitan Plus os padrões de cera foram incluídos à vácuo com três diferentes concentrações do líquido especial, 100%, 75% e 50%, diluídos em água destilada. As fundições foram realizadas na máquina Discovery Plasma com os moldes em três temperaturas, 430ºC, 515ºC e 600ºC. Os revestimentos alternativos foram empregados nas condições em que obtiveram expansão total de 0,8%, equivalente à do Rematitan Plus (100%/430ºC), adotado como grupo controle. Conforme as curvas de expansão de presa e térmica foram estabelecidas as condições de concentração e temperatura: Rema Exakt (100%/220ºC, 75%/240ºC e 50%/340ºC) e Castorit Super C (100%/temperatura ambiente e 75%/160ºC). / Abstract: This study had the goal of assessing the effect of the concentration of the special liquid and the temperature of the mold of Rematitan Plus investment, specific for titanium, Rema Exakt and Castorit Super C, alternative investments, on the marginal misfit of crowns cast on pure titanium. For the Rematitan Plus investment, the wax standards were included in vacuum with three different concentrations of the special liquid, 100%, 75% and 50%, diluted in distilled water. The castings were performed on the Discovery Plasma machine with the molds at three temperatures, 430ºC, 515ºC and 600ºC. The alternative investments were employed under conditions in which they obtained a overall expansion of 0.8%, equivalent to that of the Rematitan Plus (100%/430ºC), adopted as the control group. According to the thermal and setting expansion curves the conditions of concentration and temperature were established: Rema Exakt (100%/220ºC, 75%/240ºC and 50%/340ºC) and Castorit Super C (100%/room temperature and 75%/160ºC). / Orientador: Gelson Luis Adabo / Coorientador: Ricardo Faria Ribeiro / Banca: Marco Antonio Compagnoni / Banca: Carlos Alberto dos Santos Cruz / Banca: Mauro Antônio de Arruda Nóbilo / Banca: Cláudio Rodrigues Leles / Doutor
|
9 |
Avaliação in vitro do efeito da aplicação de carregamento oclusal na qualidade marginal de restaurações cervicais em cavidades em forma de cunha / In viitro evaluation of the effects of occlusal loading on the marginal quality of cervical tooth restoration for wedge-shaped cavitiesFrancisconi, Luciana Fávaro 27 November 2008 (has links)
A abfração, uma das causas das lesões cervicais não cariosas, caracteriza-se pela perda de tecido mineralizado, em forma de cunha, próxima à junção cementoesmalte. Hipoteticamente, é o resultado de forças oclusais excêntricas aplicadas sobre os dentes. Essas lesões são freqüentemente restauradas para impedir sua progressão, para proteger e aumentar a resistência do remanescente dental, reduzir a hiperestesia dentinária e manter a saúde periodontal. Entretanto, pouco se sabe quanto ao efeito dos fatores causadores da abfração na qualidade marginal de restaurações cervicais, quando da reabilitação dessas lesões. Este estudo in vitro propõe-se, portanto, a analisar o efeito da aplicação de carga oclusal na qualidade marginal de restaurações de cavidades cervicais em forma de cunha, utilizando microscopia confocal de varredura a laser. Para tal, foram utilizados 40 dentes prémolares superiores humanos hígidos, extraídos, nos quais foram preparadas cavidades padronizadas em forma de cunha, em sua região cervical vestibular, por meio da utilização de pontas diamantadas cilíndricas de topo plano nº 3100 (1,6 mm de diâmetro e 21 mm de comprimento), posicionadas em 45º com a superfície mais plana e próxima à junção amelo-cementária. As cavidades (1,3 mm de profundidade, 2,3 mm de abertura ocluso-cervical, 4,0 mm de abertura mésio-distal, 1,6 mm de extensão na parede oclusal e 1,9 mm de extensão na parede cervical) foram restauradas com resina composta (Z250®) em associação ao uso de um sistema adesivo (Single Bond®). Para possibilitar a análise ao microscópio confocal, o sistema adesivo foi marcado previamente com adição de rodamina B. Após imersão em água deionizada, por 7 dias e polimento das restaurações, os espécimes foram incluídos em uma matriz de resina acrílica. A porção radicular de cada dente foi revestida com uma camada de poliéter (Impregum®), de aproximadamente 1 mm, a fim de simular o ligamento periodontal. A porção coronária foi mantida totalmente exposta ao meio externo. Os dentes foram, então, submetidos à ciclagem mecânica, pela ação de uma ponta metálica em forma de torpedo, exercendo carga de 150 N, num total de 106 ciclos. Para tanto, a ponta foi posicionada de acordo com as seguintes condições experimentais: sobre a vertente triturante interna da cúspide vestibular (GI; n=10); sobre o sulco central (GII; n=10); e sobre a vertente triturante interna da cúspide lingual (GIII; n=10). O grupo controle (GIV; n=10) não foi submetido à ciclagem mecânica, permanecendo apenas armazenado em água deionizada, a 37ºC, durante todo o período experimental. Finalizada a ciclagem mecânica, as superfícies vestibulares dentárias foram, então, recobertas com duas camadas do sistema adesivo (Single Bond®), agora marcado com fluoresceína, para delimitação dos possíveis defeitos formados. Os dentes foram seccionados longitudinalmente em duas metades (mesial e distal) e submetidos à avaliação em microscopia confocal, para análise da qualidade da margem das restaurações. Foi aplicado o teste do qui-quadrado (p<0,05) para as variáveis qualitativas presença ou ausência de fendas marginais e localização das fendas em relação às paredes cavitárias (oclusal, cervical ou ambas). Para as variáveis quantitativas (amplitude e extensão das fendas) aplicou-se o teste de Kruskal-Wallis (p<0,05). Os espécimes submetidos ao carregamento oclusal, independentemente do local de aplicação da força, apresentaram maior porcentagem de fendas marginais (53,33%) quando comparados aos espécimes do grupo controle (10%; p=0,016). Não houve diferença estatisticamente significante entre o local de aplicação de força oclusal tanto para a presença ou ausência de fendas marginais (p=0,875); como para a localização das fendas em relação às paredes cavitárias (p=0,270) ou mesmo para a extensão (p=0,190) e amplitude das mesmas (p=0,070). Conclui-se, portanto, que a aplicação de carga oclusal prejudicou o comportamento marginal de restaurações cervicais, mas a variação do local de incidência de carga não interferiu no comportamento marginal das mesmas. / Tooth abfraction, one of the causes of non carious cervical lesions, is a wedgeshaped tissue loss, situated next to the cement-enamel junction, being, hypothetically, the result of eccentric occlusal loads applied to the teeth. These lesions are often restored to avoid their progression, to protect and increase remnant tooth resistance, to reduce dental hypersensitivity and to maintain periodontal health. However, there is little knowledge about the effect of abfraction etiology factors on the restoration marginal quality in the rehabilitation of these lesions. This in vitro study intends, therefore, to analyze the effect of the application of occlusal load on the marginal quality of cervical restorations in wedge-shaped cavities, by employing laser scanning confocal microscopy. Standardized wedge-shaped cavities were prepared in the cervical buccal region of 40 sound extracted upper human premolars, by the use of a cylindrical diamond bur #3100 (1.6 mm in diameter and 21 mm in length), positioned in 45º with the surface that is plainer and closer to the cementenamel junction. The cavities (1.3 mm in depth, 2.3 mm in occluso-cervical opening, 4.0 mm in mesio-distal opening, 1.6 mm in occlusal wall length and 1.9 mm in cervical wall length) were filled with a composite resin (Z250®) associated with the use of an adhesive system (Single Bond®). For the analysis at the confocal microscope to be possible, the adhesive system was previously modified by the addition of rodhamine B. After storage in deionized water for 7 days, and after the finishing and polishing of the restorations, specimens were included in acrylic resin matrixes. The radicular portion of each tooth was covered by an approximately 1 mm layer of a polyether (Impregum®), for the creation of an artificial periodontal ligament. The crown portion was kept totally exposed to the external environment. Teeth were, then, submitted to the mechanical cycling, by the action of a torpedo-shaped tip that exerted a 150 N load for a total of 106 cycles. The tip was positioned according to the following experimental conditions: over the internal triturant vertent of the buccal cusp GI; n=10); over the centre of the fissure (GII; n=10); and over the internal triturant vertent of the lingual cusp (GIII; n=10). The control group (GIV; n=10) was not submitted to the mechanical cycling, staying only stored in deionized water, at 37oC, during the whole experimental period. When the mechanical cycling was over, buccal dental surfaces were, then, covered with two layers of the adhesive system (Single Bond®), now modified by the addition of fluorescein, for delimitation of the possible formed defects. Teeth were longitudinally sectioned into two halves (mesial and distal ones), and submitted to evaluation through confocal microscopy, for analysis of the restorations marginal quality. Chi-square test (p<0.05) was applied for evaluation of qualitative variables (presence or absence of marginal defects and their location according to the cavity walls occlusal, cervical or both); and Kruskal-Wallis test (p<0.05) was applied for evaluation of quantitative variables (length and width of the defects). Specimens submitted to occlusal loading, independently of the location of the tip, presented a higher percentage of marginal defects (53.33%), when compared to the control group (10%; p=0.016). There was no significant statistical difference among the local of load placement for the presence or absence of marginal defects (p=0.875); for their localization according to the cavity walls (p=0.270); or even for their length (p=0.190) and width (p=0.070). It can be concluded, therefore, that occlusal loading was harmful for the margins of cervical restorations; but the different local of its incidence did not interfere with their marginal quality.
|
10 |
Avaliação da desadaptação marginal de estruturas metálicas obtidas com variações quanto aos tipos de cera e às técnicas de inclusão e fundiçãoMarchiori, André Vinícius [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0
Previous issue date: 2004Bitstream added on 2014-06-13T20:18:36Z : No. of bitstreams: 1
marchiori_av_me_araca.pdf: 946522 bytes, checksum: ed4cd9e55e14d7d9431de58e44b8da02 (MD5) / Cng Solucoes Proteticas / Talladium do Brasil / O objetivo deste trabalho foi observar o comportamento de ceras para fundições, utilizando a técnica de fundição convencional, comparando-a a técnica de fundição rápida; utilizando em ambas a expansão higroscópica de um revestimento fosfatado (All Therm, CNG Soluções Protéticas). Utilizamos duas ceras: Cera para imersão GALILEO Dip Pot Wax (Talladium Inc.) e Cera Azul para fresagem (CNG Soluções Protéticas), que foram submetidas às duas técnicas de fundição propostas. Cada grupo experimental foi composto por 12 corpos de prova e, a verificação do desajuste marginal foi realizada através de um microscópio comparador digital Mitutoyo. Cada corpo de prova foi medido em quatro pontos pré-determinados no troquel metálico. A análise dos resultados demonstrou que, com a metodologia empregada, a técnica de fundição rápida apresentou desempenho favorável, quando comparado com a técnica convencional para ambas as ceras; e a cera Azul para fresagem, na técnica rápida, foi a que apresentou menor valor médio de desadaptação (sub-adaptação). Concluímos que utilizar a expansão higroscópica do revestimento fosfatado foi uma forma de viabilizar a técnica de fundição rápida, obtendo resultados favoráveis com ambas as ceras. / The purpose of this investigation was to observe and evaluate the behavior of dental casting wax in conventional and accelerated casting techniques, both using hygroscopic expansion of phosphate bonded investment, in order to determine which material or technique would provide better results about cervical fitting in the obtained metallic structure. The two casting waxes used, GALILEO Dip Pot Wax (Talladium Inc.) and Blue Wax of milling (CNG Soluções Protéticas), were submitted to both proposed casting techniques. Each experimental group was consisted of twelve specimens and, the assessment of marginal fitting was performed by means of a Mitutoyo comparator microscope. Each specimen was measured by using four pre-established points in stainless steel master die as references. From the employed methodology the analysis of the results showed that accelerated casting technique presented superior fitting in comparison with the conventional technique for both types of waxes. Besides, in the accelerated casting technique the Blue Wax of milling presented smaller mean value of unadaptation (underadaptation). We conclude that the use of the hygroscopic expansion of phosphate bonded investment was a way to viable the accelerated casting technique, obtaining favorable results with both casting waxes.
|
Page generated in 0.113 seconds