• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 907
  • 81
  • 78
  • 78
  • 78
  • 68
  • 7
  • 7
  • 6
  • 6
  • 4
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 922
  • 922
  • 454
  • 392
  • 234
  • 208
  • 160
  • 149
  • 100
  • 97
  • 81
  • 69
  • 69
  • 69
  • 66
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Resistência à remoção de braquetes ortodônticos sob ação de diferentes cargas contínuas

Francischone, Carla Giannini 14 June 2006 (has links)
O objetivo deste trabalho foi: 1 - testar se existe alteração na resistência adesiva de dois cimentos utilizados na colagem de acessórios ortodônticos ao esmalte dental bovino, sendo um de polimerização química (Concise Ortodôntico) e outro fotpolimerizável (Transbond XT), após a aplicação de cargas contínuas, mediante testes de cisalhamento, 2 - observar se há diferença entre as cargas utilizadas e 3 - analisar o tipo de falha que ocorrida no momento do deslocamento dos braquetes para os dois cimentos testados. Foram utilizados para este estudo 80 dentes bovinos, 80 braquetes metálicos (Morelli Ortodontia - Braquete Edgewise/ Rickets para colagem), e pesos com 30g, 70g e 120g. O esmalte bovino foi condicionado com ácido fosfórico a 37% por 1 minuto e depois lavado e seco. A aplicação dos adesivos, manipulação e aplicação dos dois cimentos foram feitas de acordo com as instruções dos fabricantes. Para a padronização da espessura de cimento sob o braquete, foi utilizada uma Agulha Maior de Gilmore, posicionada sobre o braquete, de modo a fazer pressão durante a presa dos cimentos. Após 24 horas, os 80 braquetes colados com Concise e Transbond XT aos dentes foram submetidos às cargas contínuas de 30g, 70g e 120g, além do grupo controle onde os espécimes não receberam carga alguma, sendo 10 corpos de prova para cada teste. Os espécimes ficaram imersos em água filtrada por 28 dias dentro de uma estufa a 37°C. Depois deste período, as amostras foram submetidas a testes de cisalhamento em uma Máquina de Ensaios Universal Kratos, através de um dispositivo com alça metálica acoplado à célula de carga com 500kgf a uma velocidade de 0,5mm/min. Os resultados foram registrados e enviados para análise estatística dos resultados através do teste de Análise de Variância a dois critérios de classificação. Ficou concluído que: 1 - o cimento Concise apresentou maior resistência à remoção que o cimento Transbond XT para todas as cargas utilizadas, 2 - não houve diferença estatisticamente significante entre as três cargas utilizadas para os dois cimentos testados; 3 - com relação ao tipo de falha ocorrida no momento da fratura, conforme ocorreu o aumento da carga, a porcentagem de fratura do esmalte diminuiu para o Concise, ao contrário do cimento Transbond XT , onde a porcentagem de fratura de esmalte se manteve constante com o aumento das cargas. Os dois cimentos testados obtiveram resultados aceitáveis para a utilização clínica. / The aim of this study was: 1) to test differences on bond strength between auto-cured (Concise) and light-cured (Transbond XT) cements after static loading and shear test; 2) to observe whether differences exist among static loads and 3) to analyze failure mode after bracket displacement. Eighty bovine teeth and metallic orthodontic brackets (Morelli Ortodontia Braquete Edgewise/Rickets) were tested after static loads of 30, 70 and 120 grs. Bovine enamel was conditioned with 37% phosphoric acid gel for one minute, rinsed and dried. Adhesives were applied and brackets were bonded according to manufacturer\' s instructions. Cement thickness was standardized with the use of a heavier Gilmore needle. After 24 hours, half of the specimens were submitted to the static loads of 30, 70 and 120grs. Control groups remained unloaded. Then, specimens were immersed in distilled water for 28 days at 37oC. Afterwards, orthodontic brackets were attached to a loop wire and submitted to a shear force (Máquina de Ensaios Kratos Universal Kratos) under a crosshead speed of 0.5mm/min and load cell of 500Kgf. A two-way ANOVA test (?=0.05) was used to detect significant interactions between cements and static loads. It was concluded that: 1) The Concise cement showed more statistically significant bond strength values than the TransbondXT cement for all static loads; 2) No statistically significant differences were observed regarding static loads for all cements tested and 3) Higher static loads provided less enamel fracture in the Concise group after shear test, whereas in the Transbond XT the rate of enamel fracture remained unchanged regardless of previous load applied. The two tested cements provided acceptable results for clinical application.
12

Estudo in vitro da rugosidade produzida sobre restauradores resinosos, apos escovação com diferentes tipos de escovas dentais

Kobayashi, Raquel Cristina de Oliveira 18 January 1998 (has links)
Orientador: Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontolgia de Piracicaba / Made available in DSpace on 2018-07-23T05:17:22Z (GMT). No. of bitstreams: 1 Kobayashi_RaquelCristinadeOliveira_M.pdf: 4890094 bytes, checksum: 9c20b9761040bae3ed60dd2987cb3e21 (MD5) Previous issue date: 1997 / Resumo: Este trabalho avaliou a rugosidade superficial dos restauradores 2100 e Compoglass, polimerizados sob tira de poliéster, produzida pela escovação com diferentes tipos de escovas dentais. Foram confeccionados 64 corpos-de-prova para cada material (8 mm de diâmetro por 2 mm de espessura) com preenchimento incremental da matriz e exposição individual de 60 segundos com um fotopolimerizador XL 3000 (3M). Os corpos-de-prova foram confeccionadas e armazenados por 24 horas em estufa a 37° C e 100% de umidade relativa. Os corpos de-prova foram divididos em 2 grupos de escovação utilizando água ou água e dentifrício, sendo ainda subdivididos em 4 subgrupos de acordo com O tipo de escova utilizado: Oral-B 30, Alcance Reach Control, Kolynos Doctor Flexível e Colgate Total. Antes de serem submetidos ao teste de escovação, os corpos-de-prova foram analisados com o auxilio de um rugosímetro Prazis. Em seguida, os corpos-de-prova foram ensaiados numa máquina de escovação, com velocidade de 250 ciclos/minutos, sob pressão de 200g, num total de 30.000 ciclos. Após o ensaio, a rugosidade superficial dos corpos-de-prova foi analisada e os resultados submetidos à análise de variância e ao teste de Tukey, ao nível de 1 % de significância. Os resultados mostraram que a escova dental não provocou rugosidade acentuada nos materiais restauradores. O m aterial Compoglass, quando escovado com dentifrício associado com escova dental Oral-B 30, apresentou a maior média numérica de rugosidade seguida por Alcance Reach Control e Kolynos Doctor Flexível, que não diferiram entre si estatisticamente, e Colgate Total com a menor média. A disposição das cerdas favoreceu ou dificultou a concentração de dentifrício sobre a superfície do material restaurador, interferindo nos níveis de rugosidade superficial. Para Z100 não houve diferença entre a rugosidade superficial produzida após a escovação com dentifrício e os diferentes tipos de escovas dentais, provavelmente devido a resistência à abrasão do material restaurador ser maior que o desgaste produzido pelo abrasivo contido no dentifrício. O mesmo não aconteceu com o Compoglass, o qual também apresentou maior valor de rugosidade superficial em relação ao Z100 / Abstract: This work evaluated the superficial roughness of Z100 and Compoglass light-cured fillings under polyester strip, produced by different types of dental brushes .It was made 64 samples for each material (8 mm of diameter for 2 mm of thickness) light-cure for 60 s with a XL 3000 (3M) light curing unit. The samples were stored by 24 hours in stove at 370 C and 100% of relative humidity. Them, they were divided in 2 brushed groups, using water or water and toothpaste, and subdivided in 4 subgrupos in agreement with the brush type: Oral-B 30, Alcance Reach Control, Kolynos Doctor Flexível and Colgate Total. After the toothbrushing test, the samples were analyzed in a Prazis perfilometer. Soon afie r, the samples were mechanically toothbrushed with a speed of 250 stroke/min, under pressure of 200g, in a total of 30.000 cycles. After the superficial roughness of the samples were analyzed and the results we[e submitted to variance analysis, at the levei of significância of 1 %. The results showed that the toothbrushing produced roughness without statistical diference in the restoring materiais, when was used water. Compoglass brushed with toothpaste associated with dental brush Oral-B 30 presented the largest average, followed by Alcance Reach Control and Kolynos Doctor Flexível, that didn't differ statistically, and Colgate Total with the smallest value of roughness. No diference for Z100 surface roughness was noted with toothpaste and diferents dentais brushes, because the material strenght was harder than toothpaste abrasion one / Mestrado / Materiais Dentarios / Mestre em Ciências
13

Avaliação da citotoxicidade de agentes clareadores dentais de uso profissional variando o mecanismo de ativação, fibroblastos de polpa humana /

Nakáo, Mariana Pretti. January 2007 (has links)
Orientador: Márcia Carneiro Valera / Banca: Antônio Carlos Bombana / Banca: José Benedito Oliveira Amorim / Resumo: A proposta deste estudo foi avaliar a citotoxicidade do peróxido de hidrogênio (PH) liberado por dois géis clareadores, utilizados para a técnica de consultório, sobre cultura de fibroblastos de polpa humana (FP5). As células foram cultivadas em DMEM. Foram utilizadas células entre a quinta e décima passagens. Colocou-se sobre as células meios de cultura condicionados de acordo com os grupos de estudo (n=4): G1- PH 35% sem fotoativação; G2- PH 35% ativado por luz alógena; G3- PH 35% ativado por diodo emissor de luz (LED); G4- PH 38% sem fotoativação; G5- PH 38% ativado por luz alógena; G6- PH 38% ativado por LED. Uma curva padrão de viabilidade e crescimento celular foi obtida a partir de células que não receberam tratamento (controle). O ensaio com MTT ocorreu após 0, 24 e 48 horas, para avaliar a viabilidade e crescimento celular. Paralelamente, mediu-se colorimetricamente a quantidade de PH liberado nas condições experimentais, utilizando-se solução tampão de acetato no lugar do meio de cultura. Os dados foram analisados através do teste de Dunnet, ANOVA e teste de Tukey. Todos os grupos apresentaram diferença significativa em relação ao controle. O PH 38% apresentou maior citotoxicidade e quantidade de peróxido de hidrogênio liberada que o PH 35% nas condições experimentais. A ativação por luz alógena ocasinou maior citotoxicidade e maior quantidade de PH liberado, e a ativação com LED foi estatisticamente semelhante à ausência de ativação. A avaliação após 48 horas apresentou diferença estatística das avaliações de 0 e 24 horas. Concluiu-se que: a citotoxicidade foi proporcional à concentração do agente clareador; a fotoativação com luz alógena aumentou a liberação de peróxido de hidrogênio, e o metabolismo celular foi menor imediatamente após o contato com o meio condicionado, aumentando após 24 e/ ou48 horas. / Abstract: The propose of this study was to evaluate hydrogen peroxide (HP) cytotoxicity, from two in office bleaching agents, on human pulp fibroblasts (FP5) culture. The cells were cultured in DMEM. Only cells between fifith and tenth passages were used. Each well of culture plate, corresponding to experimental groups, received conditioned middle according to the experimental groups: G1- HP 35% without light activation; G2- HP 35% activated by halogen light; G3- HP 35% activated by LED; G4- HP 38% without light activation; G5- HP 38% activated by halogen light; G6- HP 38% activated by LED. Viability and growth standard curve was obtained from an untreated group and was used as control. MTT assay was performed in four wells for each group, in periods of 0, 24 or 48 hours, to measure cells viability and growth. Hydrogen peroxide leased in experimental conditions was also measured, using acetate buffer instead culture middle. Results were analyzed by Dunnet test, variance analysis and Tukey test. All experimental groups showed difference from control. The cytotoxicity and quantity of hydrogen peroxide was higher with 38% hydrogen peroxide (Opalescence Xtra Boost) than with 35% hydrogen peroxide (Whiteness HP). Activation by halogen light caused smaller cell growth and viability but higher hydrogen peroxide amount, and LED was statically similar to the group without activation. 48 hours evaluation was different then 0 and 24 hour evaluations. Conclusions: cytotoxicity was proportional to quantity of hydrogen peroxide leased; halogen light activation increased the leased hydrogen peroxide, and cell viability was lower immediately after contact with conditioned middle, increasing after 24 and/or 48 hours. / Mestre
14

Análise morfológica da superfície dos cones de guta-percha submetidos à desinfecção com hipoclirito de sódio a 1% e a 2,5% e sua influência no selamento marginal da obturação /

Brito, Selma Maria Santos Moura. January 2007 (has links)
Orientador: Simone Helena Gonçalves de Oliveira / Banca: Simone Helena Gonçalves de Oliveira / Banca: Celso Kenji Nishiyama / Banca: Claudio Antonio Talge Carvalho / Resumo: A guta-percha é o material de escolha para obturação dos canais radiculares. Como pode entrar em contato com os tecidos apicais e periapicais no momento da obturação, os cones devem ser desinfectados antes do uso para que não sirvam de veículo para microrganismos patogênicos. A proposta deste estudo foi avaliar o efeito do NaOCl a 1% e a 2,5% sobre a morfologia superficial dos cones de guta-percha em função do tempo de imersão e analisar o selamento marginal de canais obturados com estes cones. Para isto, foi analisada pelo MEV a morfologia superficial de 110 cones de guta-percha principal, divididos em 3 grupos: G1 (controle), G2 e G3 imersos no NaOCl 1% e 2,5% durante 30 min, 6, 12 e 24h. Para análise do selamento foram utilizados 72 dentes unirradiculados humanos com o comprimento das raízes padronizados entre 16 - 18 mm, que foram divididas em 6 grupos, instrumentadas e obturadas com o cimento endodôntico AH Plus e com os cones imersos nas soluções de NaOCl 1% e 2,5% nos tempos convencionais, utilizados como controles (A e B) e durante 30 min e 24h (grupos C, D, E e F); duas raízes serviram de controle interno + e -. As raízes foram impermeabilizadas externamente, exceto no forame apical, imersas no corante tinta da Índia por 24h e diafanizadas. A leitura das microinfiltrações foi realizada pelo esteromicroscópio, as imagens obtidas foram fotografadas e salvas no computador para medir as microinfiltrações utilizando o programa Image Tool. Os resultados mostraram alteração gradativa crescente na morfologia superficial dos cones de acordo com o aumento da concentração do NaOCl e do tempo de imersão. As médias de microinfiltração obtidas em mm foram de: A = 1,14; B = 1,22; C = 1,17; D = 1,26; E = 1,44 e F = 1,60. Através do Teste Dunnett e da análise de variância (ANOVA) não houve diferença estatisticamente significante... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Gutta-percha is the material of choice for root canal filling. Considering that it may contact the apical and periapical tissues during root canal filling, they must be disinfected before use to avoid the propagation of pathogenic microorganisms. The purpose of this study was to evaluate the effect of 1% and 2.5% sodium hypochlorite on the surface morphology of gutta-percha points according to the period of immersion, and to analyze the marginal sealing of root canal filling with these points. The surface morphology of 110 gutta-percha points was analyzed by scanning electron microscopy; the points were divided into 3 groups: G1 (control), G2 and G3, respectively immersed in 1% and 2.5% sodium hypochlorite, for 30 minutes, 6, 12 and 24 hours. Analysis of marginal sealing was performed on 72 single-rooted human teeth with standardized root length of 16-18 mm, divided into 6 groups, prepared and filled with AH Plus sealer with the points immerged in 1% and 2.5% sodium hypochlorite, the conventional times were taken as control (A and B) end during 30 minutes and 24 hours (groups C, D, E and F);). The roots received an impermeable coating on the external surface, except for the apical foramen; the roots were then immersed in India ink for more than 24 hours and were made transparent. Reading of the microleakage was performed by the stereomicroscope; the obtained images were photographed and saved in the computer for microleakage measurement using the softwere Image Tool. The results showed increasing and progressive alteration in the surface morphology of points according to the increase in sodium hypochlorite concentration and period of immersion. The microleakage means obtained in mm were: A = 1.14; B = 1.22; C = 1.17; D =1.26; E = 1.44 and F = 1.60. Application of the Dunnett test and analysis of variance did not reveal statistically... (Complete abstract, click electronic access below) / Mestre
15

Análise comparativa da adaptação marginal de componentes pré-fabricados e fundidos sobre pilares ceraone.

Manhães, Lussara Azevedo 16 June 1999 (has links)
O critério mais importante para a aceitabilidade clínica de uma restauração indireta é o grau de adaptação marginal. Em próteses sobre implantes também torna-se necessária a obtenção de adequada adaptação marginal para a manutenção da saúde periimplantar e obtenção da longevidade da prótese. Avaliou-se “in vitro" a adaptação marginal na interface intermediário CeraOne(Nobel Biocare- Gotemburgo, Suécia) e cinco tipos de coifas: coifa cerâmica pré-fabricada CeraOne(DCA 127), In Ceram(Vita-Alemanha), coifa préfabricada poliacrílica do sistema CeraOne(DCA 131), IPS Empress(Ivoclar- Schaan, Liechtenstein) e Fortune(Williams- Amherst, NY, Labordental-São Paulo). As coifas obtidas foram assentadas em um intermediário CeraOne(SDCA 334) e a adaptação marginal foi avaliada, segundo critérios de ajuste e desajuste marginal, em 6 pontos, determinados pelo sextavado do intermediário. De acordo com a análise estatística dos resultados, foi possível concluir que as coifas cerâmicas pré-fabricadas CeraOne(DCA 127) exibiram a maior quantidade de ajustes e os menores valores de desajuste, sendo consideradas a melhor opção restauradora sobre intermediários CeraOne. As coifas In Ceram apresentaram resultados muito satisfatórios, assim como as coifas IPS Empress. Esses dois sistemas são considerados aceitáveis para a utilização sobre intermediários CeraOne, como segunda opção e em casos selecionados. As coifas de porcelana fundida sobre refratário não exibiram resultados satisfatórios, quando comparadas aos demais grupos, sendo considerada uma técnica desaconselhável para ser utilizada sobre intermediários CeraOne. / The most important rule in the clinical acceptability of na indirect restoration is the marginal fit. Implant-supported restorations also need acceptable margins for the maintenance of peri-implant health and protheses longevity. The purpose of this study is to evaluate marginal fit of the abutment CeraOne(Nobel Biocare SDCA 334- Gotemburg, Sweden) “in vitro" as well as five kinds of ceramic caps: CeraOne prefabricated ceramic cap(DCA 127), In Ceram(Vita-Germany), CeraOne prefabricated polymethyl methacrylate cap(DCA 131), IPS Empress(Ivoclar- Schaan, Liechtenstein) and Fortune(Williams- Amherst, NY, Labordental, São Paulo). The caps were seated on the CeraOne abutment and the marginal fit was examined under microscope according to the fit and misfit criteria in six faces around the margins. The results have shown that the best marginal fit was CeraOne prefabricated ceramic caps. This system is considered the first choice in the protocol for CeraOne restoration. The In Ceram and IPS Empress caps have presented satisfactory results, but IPS Empress has shown less fit and more discrepancy in comparison with In Ceram, probably due to the previous misfit of CeraOne prefabricated polymethyl methacrylate cap. These last two systems are considered acceptable to use in abutment CeraOne, but as a second option and in selected cases. The Fortune caps have not presented satisfactory results. Thus, this system is considered inadvisable for use with abutment implants.
16

Efeito de tratamento de superfície na resistência de união de uma liga de Cobalto - Cromo e uma resina acrílica termicamente ativada

Martinelli, Carolina da Silva Machado [UNESP] 06 February 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-02-06Bitstream added on 2014-06-13T19:58:20Z : No. of bitstreams: 1 martinelli_csm_me_sjc.pdf: 814469 bytes, checksum: dfa445fa4dc04c7f8a427a22c45d5eca (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A proposta deste estudo foi avaliar (1) a influência da rugosidade superficial e diferentes métodos de tratamento de superfície, na resistência de união da interface liga de Co-Cr/ RAAT; (2) a influência de diferentes métodos de envelhecimento na resistência de união da interface liga de Co-Cr/ RAAT, submetida a diferentes métodos de tratamento de superfície. Foram confeccionados 120 espécimes metálicos, em liga de Co-Cr. A superfície menor dos espécimes (Ø=7mm) foi regularizada e submetida a análise em M.O., rugosímetro e análise superficial qualitativa em MEV e quantificação de óxidos em EDS. Foi realizado o protocolo de jateamento (Al2O3), em sequência, análise em M.O., rugosímetro, MEV e EDS. Os espécimes foram divididos aleatoriamente em quatro grupos (n=30): C – controle; P – primer para metal; O – opaco cerâmico; PO – primer e opaco. Após inclusão em mufla os espécimes foram acrilizados em ciclo curto de polimerização. Após desinclusão os espécimes foram subdivididos em três grupos (n=10): armazenagem em água (A), ciclagem mecânica (CM) e ciclagem térmica (CT). Foi realizado o teste de resistência ao cisalhamento (100 Kgf – 0,5mm/min). Os resultados obtidos foram submetidos à analise estatística de alteração percentual e testes não paramétricos Kruskal-Wallis e Dunnet. Os postos médios obtidos foram: PA 103.75A; PT 99.70A; POA 86.150AB; OA 71.250ABC; OCT 77.50ABC; POCM 74.85ABC; OCM 70.55ABC; CA 44.70BCD; POCT 42.950BCD; PCM 25.60CD; CCT 14.50D; CCM 14.50D. A microrretenção mecânica não é um método efetivo para união liga de Co-Cr/ RAAT, sendo a abordagem combinada (jateamento + tratamento de superfície) mais eficiente implicando em melhores resultados de resistência de união para esta interface. Os métodos de envelhecimento influenciaram negativamente a resistência de união dos grupos C, P e PO / The propose of this study was to (1) evaluate the influence of surface roughness and the different chemical treatment method for surface treatment in the shear bond strength on the interface for the Co-Cr alloy/ RAAT; (2) the influence of different aging methods in the shear bond strength on the interface for the Co-Cr alloy/RAAT, submitted to different methods of surface treatment. 120 specimens of Co-Cr were obtained. The smaller surface (Ø: 7 mm) was regularized and analyzed in optical microscopy (OP), roughness and MEV. The elements were quantified by EDS. The sandblasting protocol (Al2O3) was done followed by further MO, roughness, MEV and EDS analysis. The specimens were randomly divided into four groups (n = 30): C- control; P – metal primer; O – ceramic opaque; and PO – primer and opaque. After flask inclusion the specimens were acrilyzed in short polymerization cycle. The specimens were deflasked and subdivided in tree groups (n = 10): water storage (A), mechanical cycling (CM) and thermic cycling. Shear bond strength test (100 kgf – 0,5 mm/ min) was performed, and data were statistical analyzed with altered percentage, Kruskal-Wallis and Dunnet tests. The median values obtained were: PA 103.75A; PT 99.70A; POA 86.150AB; OA 71.250ABC; OCT 77.50ABC; POCM 74.85ABC; OCM 70.55ABC; CA 44.70BCD; POCT 42.950BCD; PCM 25.60CD; CCT 14.50D; CCM 14.50D. The mechanical micro-retention is not an effective method to union Co-Cr alloy/RAAT. Combined method (sandblasting + surface treatment) was the most efficient resulting in greatest values of shear bond strength. Aging methods negatively influenced in the bonding strength of the C, P and PO groups
17

Avaliação da formação de fendas marginais e da microinfiltração após envelhecimento artificial, empregando adesivos autocondicionantes fotopolimerizáveis ou duais associados à resinas compostas de diferentes viscosidades

Cortez Gutierrez, Natália [UNESP] 03 February 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-02-03Bitstream added on 2014-06-13T19:30:38Z : No. of bitstreams: 1 cortezgutierrez_n_me_sjc.pdf: 506799 bytes, checksum: a3d1f487a88eff53ff5b862caa6518e1 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar a influência do tipo de resina composta com relação à viscosidade, do tipo de adesivo autocondicionante e seu modo de presa e do envelhecimento artificial, na formação de fendas marginais e microinfiltração de restaurações de resina composta. Cavidades padronizadas com 4 mm de diâmetro e 2,5 mm de profundidade foram preparadas em 240 incisivos bovinos. Eles foram divididos em 2 grupos de acordo com a viscosidade da resina composta: GC - Grandio SO (Voco - viscosidade convencional) e GF - Grandio SO Heavy Flow (Voco - baixa viscosidade), ambas com alto conteúdo de carga. Cada grupo foi dividido em seis subgrupos, de acordo com os sistemas adesivos utilizados: FM - Futura Bond M (Voco), FDCF - Futura Bond DC (Voco) - fotopolimerizado, FDCQ - Futura Bond DC (Voco) – apenas polimerização química, CS – Clearfil S3 Bond (Kuraray), CDCF – Cleafil DC (Kuraray) – fotopolimerizado e CDCQ – Clearfil DC (Kuraray) – apenas polimerização química. Metade dos espécimes foi submetida à ciclagem mecânica (300.000 ciclos) e térmica (1.000 ciclos), sendo divididos então em C – ciclados e NC – não ciclados. A maior fenda marginal presente nas margens de cada restauração foi medida em microscópio óptico, em micrometros. Para a avaliação da microinfiltração, os espécimes foram submersos em solução de nitrato de prata amoniacal 50% por 24h, lavados, colocados em revelador radiográfico por 8h sob luz fluorescente e seccionados. As interfaces foram fotografadas e a microinfiltração mensurada em milímetros. Os dados foram submetidos à ANOVA três fatores. Para fenda marginal foi encontrada diferença significativa para todos os fatores (p=0,00). Os resultados de Tukey para resina foram... / The aim of this study was to evaluate the influence of composite viscosity, adhesive systems type of cure and artificial aging on marginal gap formation and microleakage of composite resin restorations. Cavities with 4mm in diameter and 2,5mm deep were prepared in 240 bovine incisors. Teeth were divided in two groups according to the viscosity of composite resin: GC - Grandio SO (Voco - conventional viscosity), GF - Grandio SO Heavy Flow (Voco - low viscosity), both with higher filler content. Each group was divided into 6 subgroups, according to the bonding systems: FM - Futura Bond M (Voco), FDCF - Futura Bond DC (Voco) – light cured, FDCQ - Futura Bond DC (Voco) – chemical cured only, CS – Clearfil S3 Bond (Kuraray), CDCF – Cleafil DC (Kuraray) – light cured and CDCQ – Clearfil DC (Kuraray) – chemical cured only. Half of the specimens were subjected to mechanical (300.000) and thermal cycling (1.000). So specimens were then divided into WITH and WITHOUT thermo-mechanical cycling. The biggest marginal gap for each restoration was measured in an optical microscope in microns. For microleakage evaluation, specimens were submersed in 50% ammoniacal silver nitrate for 24h, washed for 20min and placed in radiographic developer for 8h under fluorescent light. Teeth were sectioned and the interface with the deepest microleakage in millimeters was measured. Data were analyzed with three-way ANOVA and Tukey´s test. For marginal gaps significant differences were shown for all factors (p=0.000). Tukey´s test results for resin were GC: 28.10a e GF: 40.60b; for adhesive CDCQ: 28.67a, CDCF: 32.25b, CS: 34.12bc, FDCF: 36.10cd, FM: 36.50cd e FDCQ: 38.46d; and for artificial aging WITHOUT: 29.05a and WITH: 39.65b. For microleakage, there were also differences for all factors (p=0.000). The results of Tukey´s test... (Complete abstract click electronic access below)
18

Influência da adição de nanopartículas de sílica nas propriedades mecânicas de gessos odontológicos

Cesero, Leonardo de January 2017 (has links)
Made available in DSpace on 2018-05-09T12:03:29Z (GMT). No. of bitstreams: 1 000488694-Texto+Completo-0.pdf: 930355 bytes, checksum: 2c97f9568abe8fdc237aa889661c8a3c (MD5) Previous issue date: 2017 / The current applications of nanotechnology in dentistry include adhesive systems and composite resins, but they are still quite limited in dental materials. Dental stone is a widely used material, and the incorporation of silica nanoparticles is still unexplored. The purpose of this study is to evaluate the behavior of the mechanical properties of dental stones with the addition of silica nanoparticles at different concentrations. A total of 180 samples were prepared, 90 for each dental stone (Durone and Fuji Rock). For the control group (CG), no silica particles were added, while test group 1 (TG1) had silica nanoparticles added to 1% by weight, and test group 2 (TG2) had silica nanoparticles added to 5% by weight. The roughness, diametral tensile strength (DTS) and compressive strength were measured 24 hours after the start of spatulation. The mean roughness values for Durone were CG= 0,55, TG1= 0,36 and TG2= 0,28 μm and for Fuji Rock were CG= 0,47, TG1= 0,31 and TG2= 0,35 μm. The mean DTS values for Durone were CG= 6,03, TG1= 5,17 and TG2= 5,02 MPa and for Fuji Rock were CG= 6,41, TG1= 5,23 and TG2= 4,56 MPa. The mean compressive strength values for Durone were CG= 35,44, TG1= 32,70 and TG2= 32,44 MPa and for Fuji Rock were CG= 42,97, TG1= 31,22 and TG2= 29,86 MPa. Surface roughness was statistically lower for the Durone and Fuji Rock stones (p< 0,001) when silica nanoparticles were added. For DTS and compressive strength, the addition of silica nanoparticles did not lead to statistically better results when compared to the control groups (p> 0,05). / A nanotecnologia na Odontologia está presente nos sistemas adesivos e nas resinas compostas, sendo sua aplicação ainda bastante limitada nos materiais dentários. O gesso odontológico é um material amplamente utilizado e a incorporação de nanopartículas de sílica é desconhecida. O objetivo do estudo é avaliar o comportamento das propriedades mecânicas dos gessos odontológicos a partir da adição de nanopartículas de sílica em diferentes concentrações. Foram confeccionadas 180 amostras, sendo 90 para cada gesso (Durone e Fuji Rock). No grupo controle (GC) não foram adicionadas partículas, no grupo teste 1 (GT1) foram adicionadas 1% em peso e o grupo teste 2 (GT2) recebeu 5% em peso de nanopartículas de sílica. Os testes de rugosidade, tração diametral (DTS) e compressão foram realizados após 24 horas do início da espatulação. Os valores médios de rugosidade para o Durone foram de GC= 0,55, GT1= 0,36 e GT2= 0,28 μm e para o Fuji Rock foram de GC= 0,47, GT1= 0,31 e GT2= 0,35 μm. Para DTS foram de GC= 6,03, GT1= 5,17 e GT2= 5,02 MPa para o Durone e para o Fuji Rock foram de GC= 6,41, GT1= 5,23 e GT2= 4,56 MPa. Para compressão foram de GC= 35,44, GT1= 32,70 e GT2= 32,44 MPa para o Durone e para o Fuji Rock foram de GC= 42,97, GT1= 31,22 e GT2= 29,86 MPa. Houve uma menor rugosidade superficial estatisticamente para os gessos Durone e Fuji Rock (p< 0,001) quando adicionadas nanopartículas de sílica. Para a DTS e compressão não houve estatisticamente resultados melhores quando adicionadas nanopartículas de sílica em comparação aos grupos controles (p> 0,05).
19

Adaptação marginal e resistência à fratura de coroas totais executadas em diferentes sistemas /

Campos, Roberto Elias. January 2005 (has links)
Orientador: Osmir Batista de Oliveira Júnior / Banca: José Roberto Cury Saad / Banca: Marcelo Ferrarezi de Andrade / Banca: Adair Luiz Stefanello Busato / Banca: Paulo Sérgio Quagliatto / Resumo: O objetivo deste trabalho foi avaliar a adaptação marginal e a resistência à fratura de coroas totais metalocerâmicas e de coroas sem reforço de infra-estrutura metálica, utilizando-se diferentes sistemas restauradores. Foram selecionadas 48 raízes de dentes bovinos com diâmetros e formas semelhantes, seccionadas com 15 mm de comprimento. Após tratamento endodôntico e alívio do conduto pinos metálicos com 12 mm de comprimento foram fixados com cimento de fosfato de zinco e um preenchimento coronário de resina composta micro-híbrida foi construído com 3 mm de altura e convergência axial de aproximadamente 6 graus. O término cervical foi o ombro arredondado com 1,0 mm de largura. As amostras preparadas e seus respectivos modelos foram aleatoriamente distribuídos em 6 grupos com 8 amostras cada. As amostras foram, então, submetidas a carga de compressão em uma máquina de ensaios EMIC, a uma velocidade de 1 mm/min.. Após obtenção dos valores de resistência à fratura cada amostra foi submetida a uma inspeção visual na lupa estereoscópica para análise do modo de fratura. Para os valores de resistência à fratura, submetidos à análise estatística, o teste de Kruskall-Wallis acusou diferença significante e o teste U de Mann-Whitney indicou os locais de diferença. A análise do modo de fratura mostrou que o remanescente dental foi pouco afetado nas amostras dos grupos das coroas metalocerâmicas (Grupos A e B). Nos grupo C, D e E metade das fraturas ocorreu envolvendo somente o preenchimento coronário e a outra metade envolveu o preenchimento e a raiz do remanescente. O grupo F apresentou 100% de envolvimento do remanescente dental com fraturas cervicais ou longitudinais. Para os dados relativos à adaptação marginal o teste estatístico ANOVA não acusou diferença significante. Todos os grupos apresentaram valores dentro do limite de 100 æm, aceitável clinicamente. / Abstract: The aim of this study was to evaluate the marginal adaptation and fracture resistance of metal-ceramic and metal-free prosthetic unit crowns made with different systems. Forty-eight bovine roots with 15 mm in length were used. After endodontic treatment a metallic post (12 mm) was fixed with zinc phosphate cement and a core of micro-hybrid resin was built up with 3 mm in height, round shoulder cervical termination with 1,5 in width and an approximate axial convergence of 6 degree. Fracture failure mode showed that subjacent structure were little affected in the specimens of metal ceramic groups (A and B). However, inside groups C, D and E half of the fractures involved only the core and the other half involved the core and the remaining dental root. The most catastrophic was the group F with 100% of dental remaining involved, showing cervical and longitudinal fractures in the roots. For marginal adaptation Analysis of Variation (p<0,05) showed no differences among all groups. Means of each group were: A - (74 æm); B (102 æm); C (87 æm); D (99 æm);E (80 æm); F (100 æm). All groups had marginal gap within 100 æm, clinically accepted. / Doutor
20

Eficiência de detergentes e EDTA na remoção da "smear layer" de superfícies radiculares submetidas a raspagem e aplainamento : análise através da microscopia eletrônica de varredura /

Sampaio, José Eduardo Cezar. January 1999 (has links)
Resumo: A remoção da "smear layer" é um procedimento importante para a regeneração periodontal e para o tratamento da sensibilidade dentinária. Diversos tratamentos tem sido realizados para sua remoção, porém, mostrando resultados conflitantes ou insatisfatórios. No presente estudo nos propomos a analisar através do microscópio eletrônico de varredura a eficiência dos detergentes: lauril sulfato de sódio, Plax e de mamona assim como o EDTA 24% na remoção da "smear layer". Todos os produtos testados foram aplicados com bolinha de algodão, renovada a cada 30 segundos, a qual era esfregada na superfície radicular por diferentes períodos. As fotomicrografias foram analisadas através da aplicação de um índice de remoção da "smear layer" por três examinadores calibrados e os resultados analisados estatisticamente. De acordo com nossos resultados pudemos chegar as seguintes conclusões: 1- a instrumentação com curetas de Gracey provocou a formação da "smear layer"; 2- o detergente lauril sulfato de sódio não removeu a "smear layer", tendo sido o pior resultado entre os detergentes testados; 3- Os detergentes Plax e de mamona mostraram resultados semelhantes entre si e superiores ao controle negativo e ao lauril sulfato de sódio, porém, não removeram a "smear layer" satisfatoriamente; 4- O EDTA 24% neutro mostrou ser eficiente para a remoção da "smear layer". / Abstract: Removal of the smear layer is an important procedure to achieve periodontal regeneration and to the treatment of dentinal sensitivity. A number of treatments have been used to this end although the results turned out to be conflicting or unsatisfactory. In the present study we intended to perform a SEM evaluation of the efficiency of the following detergents on smear layer removal: sodium lauryl sulphate, Plax, castor-oil bean and EDTA 24%. These substances tested were applied topically with a small piece of sterile cotton which was rubbed on root surface for different periods of time and changed every 30 seconds. The microphotographs were evaluated by three independent previously calibrated examiners that classified them according to a smear layer removal index and the results were subjected to a statistical analysis. The results obtained led to the following conclusions: 1-hand instrumentation with Gracey curettes elicited the formation of smear layer; 2-sodium lauryl sulphate did not remove the smear layer and showed the worst results of all detergents tested; 3-Plax and castor-oil detergents showed similar results represented by a partial removal of the smear layer, and these results were better than those obtained in the negative control and sodium lauryl sulphate groups; 4-neutral EDTA 24% was the most efficient detergent on smear layer removal.

Page generated in 0.1136 seconds