• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 907
  • 81
  • 78
  • 78
  • 78
  • 68
  • 7
  • 7
  • 6
  • 6
  • 4
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 922
  • 922
  • 454
  • 392
  • 234
  • 208
  • 160
  • 149
  • 100
  • 97
  • 81
  • 69
  • 69
  • 69
  • 66
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Avaliação de propriedades físico-químicas, mecânicas e antimicrobianos do MTA e cimento Portland associado a solução de nanopartículas de prata

Vázquez García, Fernando Antonio [UNESP] 25 March 2014 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-25Bitstream added on 2014-12-02T11:21:07Z : No. of bitstreams: 1 000800892.pdf: 469815 bytes, checksum: fd9da8a2cc4b0a5350e47f1859c7f5a1 (MD5) / A substituição do óxido de bismuto por óxido de zircônio (ZrO2) e a adição de nanopartículas de prata (NPsAg) pode favorecer as propriedades físico-químicas mecânicas e antimicrobianas. Capítulo 1: Foram avaliados pH, solubilidade, tempo de presa, radiopacidade e resistência à compressão. Grupos: G1 – MTA Angelus; G2 – CP/ZrO2; G3 – MTA/NPsAg; G4 –CP/ZrO2/NPsAg. O pH foi analisado em pHmetro digital, a solubilidade pela perda de massa e o tempo de presa pelo teste de Gilmore. A resistência à compressão foi avaliada em ensaio mecânico. Para análise da radiopacidade, as amostras foram radiografadas com uma escala de alumínio. Os resultados foram submetidos aos testes ANOVA e Tukey (p<0,05). O G3 apresentou aumento de pH e diminuição da solubilidade e tempo do presa inicial e final. O G4 apresentou diminuição da solubilidade e aumento da resistência à compressão. A radiopacidade dos materiais foi superior a 4 mmAl. As associações G3 e G4 apresentam propriedades físico-químicas e mecânicas adequadas. Capítulo 2: Bactérias na forma planctônica foram colocadas sobre o cimento fresco e a análise foi realizada em espectrofotômetro. Na avaliação antibiofilme, os materiais foram colocados em contato com biofilme de E. faecalis formado sobre blocos de dentina e analisados pela contagem de unidades formadoras de colônia. Os resultados foram submetidos aos testes ANOVA e Tukey (p<0,05). Na forma planctônica, melhores resultados foram encontrados no G2 e G4. Maior redução de biofilme foi apresentada pelos G3 e G4. A incorporação de NPsAg ao CP e MTA, melhora a atividade antibacteriana e antibiofilme dos materiais à base de silicato de cálcio. / The bismuth oxide replacement by zirconium oxide (ZrO2) and the addition of silver nanoparticles may improve the physicochemical, mechanic and antimicrobial properties. Chapter I: It was evaluated pH, solubility, setting time, radiopacity and compressive strength. Groups: G1-MTA Angelus; G2-PC/ZrO2; G3-MTA/NPsAg, G4-PC/ZrO2/NPsAg. The pH was measured with a digital pH meter, the solubility by the weight loss and the setting time was evaluated by Gilmore needle. Compressive strength was tested in universal testing machine. For radiopacity analysis material samples were radiographed alongside an aluminium step-wedge. The results were submitted to ANOVA and Tukey tests (p<0.05). The G3 showed a pH increase and a decrease of solubility and initial and final setting time. The G4 showed a decrease in solubility and an increase of compressive strength. All materials presented radiopacity greater than 4 mmAl. The G3 and G4 associations showed good physicochemical and mechanical properties. Chapter 2: For the first test bacterias in planktonic form were placed over fresh cement, and the analysis was performed in spectrophotometer. Also for the antibiofilm test, the samples were placed in direct contact with E. faecalis biofilm previously induced on bovine dentine and analysed by the counting of colony-forming units. The results were submitted to ANOVA and Tukey tests (p<0.05). On the planktonic form, the best results were showed by G2 and G4. The greater reduction of biofilm were showed by G3 and G4. The incorporation of NPsAg to PC and MTA improves the antibacterial and antbiofilm activity of calcium silicate cements.
182

Avaliação histológica do processo de reparação do tecido ósseo do rato frente à aplicação de um adesivo à base de cianoacrilato

Kimaid, Antonino [UNESP] 22 June 1999 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:25Z (GMT). No. of bitstreams: 0 Previous issue date: 1999-06-22Bitstream added on 2015-01-26T13:30:29Z : No. of bitstreams: 1 000124728.pdf: 3630853 bytes, checksum: 0b80fc54b1b28e8603bf29fd818551b0 (MD5) / O propósito deste trabalho foi verificar as reações teciduais em desgastes ósseos cirúrgicos experimentais após a aplicação do adesivo químico, etil cianoacrilato (Super Bonder), em osso parietal de ratos. Investigamos a sua aceitação e a sua interferência no processo de reparo ósseo, mediante estudo microscópico por meio de microscopia de luz. Nesta pesquisa, foram empregados 24 ratos machos e fêmeas brancos (Rattus norvergicus, albinus, Wistar), com peso médio de 250 a 300 gramas, os quais foram divididos em dois grupos, tratado e controle. Após a confecção do desgaste ósseo cirúrgico, no grupo tratado, foi aplicado sobre a superfície óssea o adesivo químico, etil cianoacrilato (Super Bonder). No grupo controle, nenhum material foi aplicado sobre a mesma. Em seguida, procederam-se às suturas do periósteo e da pele. Decorridos 24 horas, três, cinco, sete, trinta e sessenta dias da cirurgia, quatro animais de cada grupo foram sacrificados. As peças contendo os desgastes ósseos foram removidas em bloco, fixadas em formol a 10% por 72 horas e submetidas a análise microscópica por meio de microscopia de luz. Os resultados obtidos possibilitaram concluir que a resposta inflamatória aguda foi mais intensa no grupo tratado do que no grupo controle. O adesivo químico, etil cianoacrilato (Super Bonder), permaneceu sobre a área do desgaste ósseo até o período de observação de sessenta dias e os tecidos adjacentes ao referido material encontravam-se com aspecto de normalidade. O adesivo químico, etil cianoacrilato, não impediu o processo de reparo ósseo / This research objective was to verify the tissues reactions obtained, in surgical experimental bone defect, after the etil cyanoacrylate chemical adhesive application in rats parietal bones. 1t was investigated the acceptance or no acceptance of the tissues surround the bone defect in which was placed the etil cyanoacrylate and the control bone defect. The specimens were submitted to light microscopic analysis. 24 adults rats were used (Rattus norvergicus, albinus, Wistar) with the average weight to 300 gr. and were divided in two groups: treated and control. After the bone defects were realized, etil cyanoacrylate was placed over one of the defects at the parietal bone (treated group). On the other defect nothing was placed and it was used like control group. After 24 hours, 3,5,7,30 and sixty days after surgery, for animals of each group were sacrificed. The bone samples were removed and fixed in 10% formalin during 72 hours and analyzed using light microscopy. The results showed that the acute inflammatory responses was more observed at lhe treated group than the control group. The chemical adhesive was observed until 60 days follow the surgery and the tissues around it present normal appearance. The chemical adhesive, etil cyanaocrylate, did not impede at the bone repair process
183

Comparação da infiltração marginal de restaurações adesivas empregando instrumento rotativo ou um sistema químico-mecânico na remoção do tecido cariado

Naressi, Suely Carvalho Mutti [UNESP] 16 August 1999 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:31Z (GMT). No. of bitstreams: 0 Previous issue date: 1999-08-16Bitstream added on 2015-01-26T13:30:17Z : No. of bitstreams: 1 000124606.pdf: 3794271 bytes, checksum: 0b7e3cd809f5ce39ab4e03000f54651a (MD5) / Considerando a validade da proposta de remoção químico-mecânica face às vantagens e indicações que o produto Carisolv apresenta e visando a realização de restaurações duradouras, esta pesquisa teve como objetivo comparar o selamento de restaurações adesivas após a remoção químico-mecânica da cárie com Carisolv (Medi Team) e com o método convencional empregando instrumentos rotatórios. Para tanto, foram utilizados sessenta dentes molares humanos cariados que após a remoção da cárie pelas duas técnicas, receberam restaurações com os materiais adesivos Vitremer (3m), Dyract (Dentsply DeTrey) e TPH Spectrum (Dentsply DeTrey). Foi empregada a metodologia para mícroinfiltração com o corante Rodamina B a 0,2% em todos os corpos de prova, que posteriormente foram seccionados em cortadeira especial e avaliados em estereomicroscópio óptico, atribuindo-se escores conforme o grau de microinfiltração observado. A análise estatística constou dos testes não paramétricos de Kruskaii-Wallis e Mann-Whitney cujos resultados evidenciaram que a infiltração marginal ocorreu na maioria das amostras avaliadas; que a diferença entre os escores apresentados pelos materiais não foi significante com a técnica convencional, porém foi significante quando o Carisolv foi empregado; que o Vitremer apresentou os mais altos valores de microinfiltração em ambas as técnicas e que a remoção do tecido cariado pelo método convencional ou químico-mecânico com Carisolv, não influenciou o desempenho selador dos materiais adesivos empregados / The chemo-mechanical removal of carious tissue using Carisolv (MediTeam) presents several advantages and indications, when lasting adhesive fillings are expected. This research proposes to compare the sealing conditions of adhesive restorations placed on teeth submitted either to the chemo-mechanical method using Carisolv or to the traditional bur method of caries removal. Sixty decayed human molars received, after the removal of the carious tissue, adhesive fillings of Vitremer (3M), Dyract (Dentsply DeTrey) e TPH Spectrum (Dentsply DeTrey). The microleakage was observed using the 0,2% Rodamine B dye method in all the samples. The samples were sectioned and examined under optical stereomicroscopy. The statistical analysis using the Kruskall-Wallis and Mann-Whitney non-parametrics tests showed the existence of marginal leakage in most samples; the differences observed in the materials tested were not significant when the traditional method was used but a statistically significant difference existed when Carisolv was employed; the highest levels of microinfiltration occured with Vitremer and the sealing properties of the various adhesive materials were not influenced by the caries removal method applied
184

Avaliação da microinfiltração marginal em restaurações de resina composta, quando o colágeno dentinário é mantido ou eliminado após o condicionamento ácido, alterando-se o período de armazenamento e a termociclagem

Torres, Carlos Rocha Gomes [UNESP] 15 March 2002 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:31Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-03-15Bitstream added on 2015-01-26T13:30:16Z : No. of bitstreams: 1 000148105.pdf: 6603398 bytes, checksum: b573466a374fbc1a46aedaa48a08fe0f (MD5) / O objetivo deste estudo foi avaliar o grau de microinfiltração marginal em restaurações de resina composta, diante das variáveis remoção ou não do colágeno dentinário após o condicionamento ácido, e utilização ou não de uma camada de resina composta fluida sobre a dentina desproteinizada, alterando-se os seguintes fatores: a)tempo de armazenagem (0, 6 e 12 meses): b) ciclagem térmica (500, 1.500 e 2.500 ciclos). Para tal, 180 dentes bovinos receberam preparos classe V ao nível da junção amelocementária. Eles foram divididos em três grupos: grupo C - foi aplicado o sistema adesivo Single Bond (3M), segundo as recomendações do fabricante, e a seguir procedida a restauração com a resina composta Z250 (3M); grupo H - após o condicionamento ácido foi aplicada uma solução aquosa de NaOCI a 10% por 1 min, e então aplicado o adesivo Single Bond e a resina composta Z250; grupo HF- semelhante ao grupo H, exceto que após a polimerização do adesivo, uma fina camada de resina composta fluída Natural Flow (DFL) foi aplicada e polimerizada, antes da inserção da resina Z250. Todos os espécimes sofreram 500 ciclos ténnicos (5 ±5°C a 55 ±5°C). Os espécimes em cada grupo foram divididos ao acaso em três subgrupos. No primeiro, a microinfiltração marginal foi avaliada após 24h. No segundo, os espécimes permaneceram imersos em água destilada contendo 0,4% de azida sódica em estufa a 37°C por seis meses, sendo que após este período sofreram mais 1.000 ciclos térmicos. No terceiro, os espécimes permaneceram imersos por 12 meses, e receberam mais 1.000 ciclos térmicos a cada 6 meses, totalizando 2.500 ciclos. Após os respectivos períodos de armazenagem, a microinfiltração marginal foi avaliada pelo método do nitrato de prata seguido pela diafanização. Os espécimes foram analisados em estereomicroscópio e receberam escores de 0 a 4. Os dados... / The aim of this study was to evaluate the marginal microleakage in composite resin restorations. under the variables removal or not of the dentin collagen after the acid conditioning, and utilization or not of a flowable composite resin layer on deproteinized dentin, changing the factors: a) storage time (0, 6 and 12 months); b) thermal cycling (500, 1.500 and 2.500 cycles). For this, 180 bovine teeth received class V cavit preparation at cementun-enamel junction. They were assigned to three groups: group C - was applied the Single Bond adhesive system (3M), according to manufacturer instructions, and restored with Z250 composite resin (3M); group H - after the acid conditioning was applied a 10% NaOCI aqueous solution for 1min, and then applied the adhesive and restored with Z250; group HF - like the group H, except that after the adhesive polymerization. a thin layer of a flowable composite resin Natural Flow (DFL) was applied and polimerized, before the placement of Z250. AIl specimens received 500 thermal cycles (5±5'C to 55±5-'C). The specimens in each group were randomly assigned to three subgroups. In the first, the microleakage was evaluated after 24h. In second, the specimens were stored in distillate water containing 0,4% of sodium azide in stove at 37'C, for 6 months, and after this time received more 1.000 thermal cycles. In the third, the specimens were stored for 12 months, and they received more 1.000 thermal cycles for each 6 months. At the end of each storage time, the microleakage was evaluated by the silver nitrate method, followed by cleaning technique. The specimens were analyzed in stereomicroscope and received scores of 0 to 4. The data were submitted to statistical analysis, using the Kruskal Wallis's and Multiple Comparisons tests. After 6 months of storage, the groups H and HF showed falls in microleakage, while the group C didn't showed significant differences
185

Estudo comparativo in vitro da resistência ao cisalhamento de sistemas adesivos em dentina humana: uso de hipoclorito de sódio em sistemas convencionais ou primers acidificados

Pucci, Cesar Rogério [UNESP] 11 December 2002 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:31Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-12-11Bitstream added on 2015-01-26T13:30:16Z : No. of bitstreams: 1 000185829.pdf: 6961073 bytes, checksum: 5b5886f8bdc5cdb65a37f1d7e96773e8 (MD5) / O objetivo deste estudo foi avaliar comparativamente, in vitro, a resistência adesiva ao cisalhamento de sistemas adesivos convencionais come sem a remocão do colágeno com hipoclorito de sódio a 10% e adesivos autocondicionantes. Utilizou-se 48 molares humanos extraídos por indicacão cirúrgica ou ortodôntica que, após a limpeza, foram armazenados em freezer a -18°C. Os dentes foram seccionados em urn plano axial mésio-distal separando-os em duas metades, vestibular e lingual. Após o embutimento em resina acrílica, tiveram as superfícies vestibular e lingual desgastadas com lixa numa sequência de granulacão decrescente para padronizar a smear layer e expor a dentina até a espessura de 2 mm. A área de adesão foi delimitada em 3 mm de diâmetro. Os espécimes foram divididos em seis grupos, de acordo com o sistema adesivo e o tratamento dentinário realizado: OBF - adesivo autocondicionante One-Up Bond F (Tokuyama); CSEB - primer autocondicionante Clearfil SE Bond (Kuraray); SB -Single Bond (3M); SBMP - Scotchbond Multi Uso Plus (3M); SBH – após o condicionamento ácido foi utilizado o hipoclorito de sódio a 10% (AD Gel - Kuraray) durante um minuto e em seguida utilizado o Single Bond; SBMPH - após o condicionamento ácido foi utilizado o hipoclorito de sódio a 10% (AD Gel - Kuraray) durante um minuto e, em seguida, utilizado o Scotchbond Multi Uso Plus. A resina composta Z-100 (3M) foi inserida pela técnica incremental, em matriz metálica, sobre a área preparada. 0 ensaio mecânico de cisalhamento foi realizado em uma máquina lnstron Universal à velocidade de 0,5 mm/min. As superfícies fraturadas foram analisadas em estereomicroscópio (Karl Zeiss). Os dados foram submetidos à análise estatística, empregando-se os testes ANOVA e Tukey. Os resultados demonstraram os seguintes valores em MPa: CSEB - 24,362; SB - 20,956; SBH- 17,825; OBF - 17,355; SBMP - 17,218; SBMPH-14,169. Concluimos que... / The aim of this study was to investigate comparatively in vitro the shear bond strength of conventional adhesive systems with and without collagen removal using 10 % sodium hypochlorite and self-etch adhesives. 48 human's molars were extracted for surgery and orthodontic reasons and after cleaning, they were stored in freezers (-18º C). The teeth were sectioned in an axial plan (mesio-distal), separated in two halves, vestibular and lingual. The teeth were mounted in self-cure resin and the labial and lingual surfaces were ground with sequential abrasive sandpaper to standardize the smear layer and expose the dentin with 2 mm of the thickness. The adhesion surface was delimited in 3 mm of diameter, the specimens were separated into six groups in accordance with adhesive system and dentin treatment: OBF - self-etch adhesive One-Up Bond F (Tokuyama); CSEB- self-etch primer Clearfil SE Bond (Kuraray); SB - Single Bond (3M); SBMP - Scotchbond Multi Uso Plus (3M); SBH - after acid etching was used at 10% sodium hypochlorite (AD Gel - Kuraray) during one minute and then Single Bond was used; SBMPH - after the acid etching sodium hypochlorite at 10% was used (AD GelKuraray) during one minute and then Scotchbond Multi Uso Plus was used. The composite resin Z-100 (3M) was inserted by incremental technique with a metallic matrix on a prepared surface. The shear test was realized in an lnstron Universal machine at 0,5 mm/min speed. The fractured surfaces were classified in stereomicroscopic (Karl Zeiss). The data obtained was analyzed by ANOVA and Tukey tests. The data showed the following values (in MPa): CSEB- 24,362; SB- 20,956; SBH - 17,825; OBF - 17,355; SBMP - 17,218; SBMPH- 14,169. We concluded that self-etch adhesive CSEB showed bond strength significantly higher than OBF and SBMP adhesives; the self-etch adhesive with acidificate primer showed bond strength statistically higher than where...
186

Estudo comparativo in vitro da resistência ao cisalhamento de sistemas adesivos em dentina humana : uso de hipoclorito de sódio em sistemas convencionais ou primers acidificados /

Pucci, Cesar Rogério. January 2002 (has links)
Orientador: Maria Amélia Máximo de Araújo / Banca: João Candido de Carvalho / Banca: Maria Antonia Pereira / Banca: Savério Mandetta / Banca: Regina Célia Santos Pinto Silva / Resumo: 0 objetivo deste estudo foi avaliar comparativamente, in vitro, a resistência adesiva ao cisalhamento de sistemas adesivos convencionais come sem a remocão do colágeno com hipoclorito de sódio a 10% e adesivos autocondicionantes. Utilizou-se 48 molares humanos extraídos por indicacão cirúrgica ou ortodôntica que, após a limpeza, foram armazenados em freezer a -18°C. Os dentes foram seccionados em urn plano axial mésio-distal separando-os em duas metades, vestibular e lingual. Após o embutimento em resina acrílica, tiveram as superfícies vestibular e lingual desgastadas com lixa numa sequência de granulacão decrescente para padronizar a smear layer e expor a dentina até a espessura de 2 mm. A área de adesão foi delimitada em 3 mm de diâmetro. Os espécimes foram divididos em seis grupos, de acordo com o sistema adesivo e o tratamento dentinário realizado: OBF - adesivo autocondicionante One-Up Bond F (Tokuyama); CSEB - primer autocondicionante Clearfil SE Bond (Kuraray); SB -Single Bond (3M); SBMP - Scotchbond Multi Uso Plus (3M); SBH - após o condicionamento ácido foi utilizado o hipoclorito de sódio a 10% (AD Gel - Kuraray) durante um minuto e em seguida utilizado o Single Bond; SBMPH - após o condicionamento ácido foi utilizado o hipoclorito de sódio a 10% (AD Gel - Kuraray) durante um minuto e, em seguida, utilizado o Scotchbond Multi Uso Plus. A resina composta Z-100 (3M) foi inserida pela técnica incremental, em matriz metálica, sobre a área preparada. 0 ensaio mecânico de cisalhamento foi realizado em uma máquina lnstron Universal à velocidade de 0,5 mm/min. As superfícies fraturadas foram analisadas em estereomicroscópio (Karl Zeiss). Os dados foram submetidos à análise estatística, empregando-se os testes ANOVA e Tukey. Os resultados demonstraram os seguintes valores em MPa: CSEB - 24,362; SB - 20,956; SBH- 17,825; OBF - 17,355; SBMP - 17,218; SBMPH-14,169. Concluimos que... / Abstract: The aim of this study was to investigate comparatively in vitro the shear bond strength of conventional adhesive systems with and without collagen removal using 10 % sodium hypochlorite and self-etch adhesives. 48 human's molars were extracted for surgery and orthodontic reasons and after cleaning, they were stored in freezers (-18º C). The teeth were sectioned in an axial plan (mesio-distal), separated in two halves, vestibular and lingual. The teeth were mounted in self-cure resin and the labial and lingual surfaces were ground with sequential abrasive sandpaper to standardize the smear layer and expose the dentin with 2 mm of the thickness. The adhesion surface was delimited in 3 mm of diameter, the specimens were separated into six groups in accordance with adhesive system and dentin treatment: OBF - self-etch adhesive One-Up Bond F (Tokuyama); CSEB- self-etch primer Clearfil SE Bond (Kuraray); SB - Single Bond (3M); SBMP - Scotchbond Multi Uso Plus (3M); SBH - after acid etching was used at 10% sodium hypochlorite (AD Gel - Kuraray) during one minute and then Single Bond was used; SBMPH - after the acid etching sodium hypochlorite at 10% was used (AD GelKuraray) during one minute and then Scotchbond Multi Uso Plus was used. The composite resin Z-100 (3M) was inserted by incremental technique with a metallic matrix on a prepared surface. The shear test was realized in an lnstron Universal machine at 0,5 mm/min speed. The fractured surfaces were classified in stereomicroscopic (Karl Zeiss). The data obtained was analyzed by ANOVA and Tukey tests. The data showed the following values (in MPa): CSEB- 24,362; SB- 20,956; SBH - 17,825; OBF - 17,355; SBMP - 17,218; SBMPH- 14,169. We concluded that self-etch adhesive CSEB showed bond strength significantly higher than OBF and SBMP adhesives; the self-etch adhesive with acidificate primer showed bond strength statistically higher than where... / Doutor
187

Abordagens estatísticas em testes de resistência de união entre dentina bovina, sistema adesivo e resina composta /

Balducci, Ivan. January 2014 (has links)
Orientador: Marcia Carneiro Valera / Co-orientador: Rodrigo Máximo de Araujo / Banca: César Rogério Pucci / Banca: Eron Toshio Colauto Yamamoto / Banca: Lilian Maekawa / Banca: Alberto Noriyuki Kojima / Resumo: O objetivo deste estudo foi empregar diferentes abordagens estatísticas em dados obtidos em ensaios de micro e macrotração, em dois períodos de tempo de armazenamento, a fim de descrever e quantificar a variabilidade comumente encontrada nos testes de adesão. Foram selecionados 48 dentes bovinos. As raízes seccionadas a 2 mm abaixo da junção cementoesmalte e as faces vestibulares foram desgastadas expondo superfície de dentina plana. Os dentes foram embutidos em resina acrílica e aleatoriamente designados a quatro grupos (n = 12) para avaliação da resistência de união (RU). Para o teste de microtração foi aplicado o adesivo Adper Single Bond 2- (SE Bond 2- 3M-ESPE) numa área de 8 mm2, seguido de jato de ar por 2 a 5 s e fotopolimerização por 15 s e, a seguir, inserida a resina composta Z350 XT- (3 M-ESPE). Após 24 h de armazenamento, em água destilada a 37 ºC, para cada dente um número variável de palitos foi obtido. Doze dentes foram submetidos ao teste de microtração após 24 h (G1) e outros 12 submetidos à termociclagem (G2) seguido de microtração. Para a macrotração, a base menor dos espécimes cônicos foi de 2 mm. Doze amostras após 24 h foram submetidas ao teste de macrotração (G3) e as outras doze, após as 24 h, termocicladas (G4). Os dados foram submetidos a uma análise exploratória; seguidos de uma análise confirmatória (inferencial). A estatística descritiva e o resultado da análise de Weibull para os dados de RU (MPa) foram: G1(módulo; média ± desvio padrão: 2,54; 10,76 ± 4,21); G2 (3,36; 19,34 ± 6,42); G3 (1,96; 3,17 ± 1,51; G4 (1,75; 2,86 ± 1,68). O teste ANOVA (2-way), α = 5%, indica efeito interação significante e, os testes de Tukey e de Dunn (5%), complementaram os resultados. Pôde-se concluir: as diferentes estratégias estatísticas (análise de Weibull, análise exploratória e abordagem paramétrica) indicaram os mesmo resultados. Pode-se concluir: as diferentes... / Abstract: The aim of this study was to use different statistical approaches on data obtained from micro and macrotensile tests in two periods of time storage, in order to describe and quantify the variability commonly found in adhesion tests. 48 bovine teeth were selected. The roots were sectioned 2 mm below the cement-enamel junction and the buccal surfaces were ground to exposure a dentin flat surface. The teeth were embedded in acrylic resin and randomly assigned to four groups (n = 12) to evaluate the bond strength (BS). For the microtensile test the adhesive Adper Single Bond 2 - (2 SE Bond - 3M - ESPE) was applied in an area of 8 mm2, followed by air jet during 2 to 5 s and curing for 15 s. Right after the XT - Z350 composite resin (3M ESPE) was inserted. After 24 h of storage in distilled water at 37 °C, for each tooth a variable number of sticks was obtained. Twelve teeth were submitted to microtensile test after 24 h (G1) and other 12 to thermocycling (G2) and microtensile test. For macrotensile, the smallest base of conical shape specimens was 2 mm. After 24 h twelve samples were subjected to macrontesile test (G3) and the other twelve, after 24 h, were thermocycled (G4). The data were submitted to an exploratory analysis, followed by a (inferential) confirmatory analysis. Descriptive statistics and the results of Weibull analysis for the data of BS (MPa) of the experimental conditions were: G1 (module; mean ± standard deviation: 2.54; 10.76 ± 4.21); G2 (3.36; 19.34 ± 6.42); G3 1.96; 3.17 ± 1.51; G4 (1.75; 2.86 ± 1.68). The ANOVA (2-way), α = 5%, indicated significant interaction effect, and Tukey tests and Dunn (5%), complemented the results. The conclusion is: the different statistics strategies (Weibull analysis, exploratory analysis and parametric approach) showed the same results, namely the existence of the aging effect only for the microtensile bond; in the comparison betw... / Doutor
188

Avaliação de propriedades físicas, químicas e biológicas de cimentos Portland associados a radiopacificadores micro e nanoparticulados /

Bosso, Roberta. January 2014 (has links)
Orientador: Mario Tanomaru Filho / Banca: Idomeo Bonetti Filho / Banca: Fábio Luiz Camargo Villela Berbert / Banca: Carlos Eduardo Saraiva Miranda / Banca: Celso Luiz Caldeira / Resumo: O Cimento Portland (CP) é um cimento de silicato de cálcio. Modificações em sua composição por meio de aditivos e resinas podem melhorar sua manipulação e presa. Foram avaliados MTA Angelus e diferentes cimentos de silicato de cálcio: puro (CSC), modificado (CSCM), resinoso 1 (CSCR1), resinoso 2 (CSCR2) e resinoso 3 (CSCR3). Dois cimentos foram selecionados para avaliação em associação aos radiopacificadores: óxido de zircônio (ZrO2) ou óxido de nióbio (Nb2O5) micro ou nanoparticulado, tungstato de cálcio (CaWO4) ou óxido de bismuto (Bi2O3). Na primeira etapa (Capítulo 1) foram avaliados tempo de presa, escoamento, resistência à compressão, quantificação de arsênio, radiopacidade e viabilidade celular. Na segunda etapa, os materiais CSCM e CSCR2 associados aos radiopacificadores forma avaliados quanto ao tempo de presa, escoamento, solubilidade, radiopacidade, resistência à compressão, pH, cálcio (capítulo 2); além de superfície, composição química, MTT e apoptose/necrose (capítulo 3). Os dados foram submetidos à análise de variância e teste de Tukey (p˂0,05). Todos os cimentos apresentaram arsênio em níveis compatíveis com o uso clínico, e mostraram biocompatibilidade. O CSCR2 apresentou maior escoamento. As associações do CSCM + CaWO4 e CSCR2 + ZrO2 e Nb2O5 micro ou CaWO4 e o MTA Angelus apresentaram menor tempo de presa, e CSCM e CSCR2 + ZrO2 micro maior escoamento. Todos os cimentos apresentaram baixa solubilidade, pH alcalino e liberaram íons cálcio. Além disso, apresentam partículas de tamanho maior que o MTA, além de cálcio e silício em sua composição e foram biocompatíveis. Concluímos que os cimentos CSCM e CSCR2 apresentam potencial uso clínico quando associado aos radiopacificadores avaliados, destacando-se o ZrO2 e Nb2O5 microparticulados. / Abstract: Portland Cement (PC) is calcium silicate cement. Changes in its composition by additives and resins can improve their handling and setting time. It was evaluated MTA Angelus and different calcium silicate cements: pure (CSC), modified (CSCM), resin 1 (CSCR1), resin 2 (CSCR2) and resin 3 (CSCR3). After selection of two cements, they were associated with radiopacifiers: zirconium oxide (ZrO2) or niobium oxide (Nb2O5) micro or nanoparticulate, calcium tungstate (CaWO4) or bismuth oxide (Bi2O3). In the first fase (Chapter 1), setting time, flow, compressive strength, quantification of arsenic, radiopacity and cell viability were evaluated. In the second study, it were evaluated the setting time, flow, solubility, radiopacity, compressive strength, pH, calcium (Chapter 2), in addition to surface chemical composition, MTT and apoptosis/necrosis (Chapter 3) of cements CSCM and CSCR2 associated to radiopacifiers. Data were subjected to analysis of variance and Tukey test (p˂0.05). All sealers showed arsenic in compatible with clinical use levels, and showed biocompatibility. The CSCR2 showed higher flow. The associations of CSCM + CaWO4 and CSCR2 with ZrO2 or Nb2O5 micro or CaWO4 and MTA Angelus had lower setting time, and CSCM and CSCR2 + ZrO2 micro largest flow. All cements showed low solubility, alkaline and released calcium ions. Also, they have particles larger than the size MTA, calcium and silicon were present in their composition and they were biocompatible. It was concluded that the CSCM and CSCR2 cements have potential clinical use when associated with radiopacifiers reviews, specially the ZrO2 and Nb2O5 microparticulated. / Doutor
189

Influência do tratamento de superfície do metal na resistência de união entre uma liga de cobalto-cromo e duas cerâmicas

Lombardo, Geraldo Henrique Leão [UNESP] 24 July 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:46Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-07-24Bitstream added on 2014-06-13T18:31:55Z : No. of bitstreams: 1 lombardo_ghl_me_sjc.pdf: 2372333 bytes, checksum: 95102ab2066b717f006018fb102db267 (MD5) / Este trabalho avaliou a influência do tratamento superficial do metal (jateamento com óxido de alumínio e ponta de tungstênio), na resistência ao cisalhamento, entre uma liga de Co-Cr (StarLoy C - DeguDent) e duas cerâmicas (StarLight Ceram - DegunDent e Duceram Kiss - Degudent). Foram confeccionados quarenta e oito padrões metálicos de formato cilíndrico, com altura total de 4,7 mm, tendo diâmetro diferenciado entre as extremidades; a maior com 5 mm e a menor com 3,7 mm (ISO 11405), sendo doze para cada grupo: G1- superfície metálica jateada com óxido de alumínio + StarLight Ceram; G2- superfície metálica tratada com ponta de tungstênio + StarLight Ceram; G3- superfície metálica jateada com óxido de alumínio + Duceram Kiss e G4- superfície metálica tratada com ponta de tungstênio + Duceram Kiss. O ensaio de cisalhamento foi realizado em máquina de ensaio universal (Emic DL 1000, São José dos Pinhais, Brasil), com célula de carga de 100 Kg, à velocidade de 0,5 mm/min, utilizando um dispositivo específico (faca com entalhe). Após o ensaio, foi realizada a análise fractográfia e os dados obtidos analisados estatisticamente pelo teste ANOVA (2 fatores). Foram observados os seguintes valores médios de resistência de união: G1 (57,97l11,34 MPa); G2 (40,62l12,96 MPa); G3 (47,09l13,19 MPa) e G4 (36,80l8,86 MPa). Concluiu-se que o tratamento superficial com óxido de alumínio, aumentou a resistência de união entre metal e cerâmica, independente do tipo de cerâmica utilizada. / The aim of this study was to evaluate the influence of the surface treatment (sandblasting with aluminium oxide and tungsten carbide bur), on the shear bond strength among a Co-Cr alloy (StarLoy C - DeguDent) and two ceramics (StarLight Ceram - DeguDent and Duceram Kiss - Degudent). Forty eigth metal cilindric specimens were made with 4,7 mm high, with two different diameters: one with 5,5 mm and the other with 3,7 mm (ISO 11405), with twelve specimens for each one of the four groups: G1 - sandblasting + StarLigth Ceram; G2 - tungsten carbide burs + StarLigth Ceram; G3 - sandblasting + Duceram Kiss and G4 - tungsten carbide burs + Duceram Kiss. The shear test was made with a universal testing machine (Emic DL 1000, São José dos Pinhais, Brazil), with load of 100 kg, with the crosshead speed of 0,5 mm/min, using a specific device (knife with an indent - Ultradent). The fracture analysis of the surfaces was made and the data were statistically analyzed with the ANOVA (two way). The means and the standard deviations of the shear bond strength were: G1 (57,97l11,34 MPa); G2 (40,62l12,9 MPa); G3 (47,09l13,19 MPa) e G4 (36,80l8,86 MPa). It could be concluded that the surface treatment with the tungsten carbide bur reduced the shear bond strength, independent of the ceramics used.
190

Estudo de propriedades físicas e químicas de um novo cimento selador endodôntico

Santos, Alaílson Domingos dos [UNESP] 12 March 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-03-12Bitstream added on 2014-06-13T19:47:25Z : No. of bitstreams: 1 santos_ad_me_ilha.pdf: 1114096 bytes, checksum: e5a41e988d95730e4d4c10dfdcc9f928 (MD5) / Na endodontia, existem certas ocorrências que exigem a aplicação de cimentos adequados para selar a comunicação entre meio interno e externo do dente. Em 1993, ocorreu a primeira publicação sobre o material “mineral trioxide aggregate”. Desde então, este material foi amplamente investigado e hoje há um reconhecimento que ele é o melhor selador existente devido suas excelentes propriedades físicas, químicas e biológicas. Uma das dificuldades encontradas pelos profissionais no uso do MTA é a trabalhabilidade e tempo de presa muito longo. Este fato motivou o desenvolvimento de um novo cimento endodôntico, intitulado Cimento Experimental. Desta forma, neste trabalho apresenta-se o resultado obtido com os estudos de: tempo de presa; liberação de íons cálcio e hidroxila; expansão térmica com amostras de cimento experimental e MTA. Para tanto, utilizou-se a técnica de microscopia de absorção atômica e de extensômetria com metodologias estabelecidas por normas específicas para determinadas medidas. / In endodontia, there are some occurrences that demand the adequate cements application to seal the communication between the tooth and the external surfaces. The mineral trioxide aggregate (MTA) was decrypted for the first time in the dental literature in 1993. Since that time, it has been widely investigated and today it is recognized as the best endodontic sealer due to its excellent physical, chemical, and biologic properties. One of the reported difficulties by professionals using MTA is associated to handling and lengthy setting time. This fact led to the development of a new endodontic cement, entitled here as Experimental Cement (EC). In this work, it reports the results obtained from the studies of: setting time; calcium and hydroxyl ions release, and thermal expansion with the MTA and EC cements. For this, technical of atomic absorption microscopy and of extensometry have been used.

Page generated in 0.063 seconds