• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 907
  • 81
  • 78
  • 78
  • 78
  • 68
  • 7
  • 7
  • 6
  • 6
  • 4
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 922
  • 922
  • 454
  • 392
  • 234
  • 208
  • 160
  • 149
  • 100
  • 97
  • 81
  • 69
  • 69
  • 69
  • 66
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
221

Análise comparativa de técnicas de apicectomia, retrocavitação e retrobturação: estudo in vitro

Post, Letícia Kirst January 2006 (has links)
Made available in DSpace on 2011-12-27T14:14:08Z (GMT). No. of bitstreams: 2 000386679-0.pdf: 2798236 bytes, checksum: 4ded65354d816ceaeaeee0f1832e9082 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Different techniques of apicectomy, retrograde preparation and root obturation were evaluated through an experimental in vitro study of apical sealing capability. Sixtyfour permanent single-rooted teeth were endodontically treated. The roots were then submitted to a root-end resection at a distance of 3 mm from the dental apex. The roots were randomly divided into two groups: 1) root-end resection in 45°; 2) root-end resection in 90°. Two types of instruments to retrograde preparation were used, nº 2 carbide bur and ultrasonic retro-tip S12/90D. Then, the entire external root surfaces of the specimens were covered with two-coats of nail polish except for the sectioned surface. Two types of retrograde filling materials were used: I) mineral three-oxide aggregate (MTA) and II) amalgam (AA). After the root-end fillings were made, the specimens were immediately immersed in a 0. 2% rhodamine B solution during 24 hours. After that, the specimens were washed in tap water for the same time and dried in environment temperature. Slices 2mm far from apex were cut and then photographed to analyze apical dye penetration and staining area (mm2) using a software (Image Tool 3. 0) in a personal computer. The results were analyzed as a ratio of dye penetration, to eliminate possible influence of differences between specimens root sizes. Data were submitted to statistical analysis using ANOVA test and post-hock LSD test, with significance of 95% (α = 0. 05).Correlation between dependent and independent variables, as between the the two examiners, Pearson’s test were assessed. None group was capable to completely seal apical stainig. Some combinations of the techniques used showed better results (p<0. 05), generally when the apicectomy was made at 90º by ultrasonic retro-tip and using MTA. Within the limitations of this study, it was concluded that the most important factor in dye penetration seems to be the retrobturator material, followed by the angle of apicectomy and retrograded instrument, respectively. / Esta pesquisa, in vitro, avaliou a influência de diferentes técnicas de seccionamento apical, preparo retrocavitário e material odontológico utilizado para retrobturação sobre a capacidade de selamento marginal por meio de teste de infiltração apical. A amostra foi constituída por 64 dentes unirradiculares tratados de maneira endodôntica, sendo metade deles aleatoriamente apicectomizados a 3mm da extremidade apical em 45º e os remanescentes com apicectomia em 90º. Para cada tipo de apicectomia foram realizados dois tipos de retrocavidade: com broca de aço esférica nº 2 ou com retroponta ultra-sônica S12/90D. Ao concluir esses procedimentos, os dentes foram isolados com duas camadas de esmalte de unhas, excetuando-se a retrocavidade e as suas margens. Para conclusão dos tratamentos, em cada subgrupo (apicectomia/retrocavidade) dois tipos de materiais odontológicos foram empregados: retrobturação com MTA ou com amálgama, sendo, então, os espécimes imediatamente imersos no corante (Rodamina B a 0,2%) por 24 horas. A infiltração apical foi avaliada, com auxílio do programa ImageTool 3. 0, a partir de fatias transversais a 2mm da extremidade apical, de cada unidade amostral, determinando-se a área de dentina infiltrada pelo corante ao redor das retrobturações, em milímetros quadrados. Este resultado, em área, foi transformado em uma medida relativa do percentual de área infiltrada, para ser avaliado sem influência de variações nas áreas das raízes nos diferentes grupos. Os dados foram submetidos à análise estatística (ANOVA e pós-teste LSD), com nível de significância de 95%. Para constatar a correlação entre a variável dependente e as independentes, bem como entre os dois avaliadores, utilizou-se o teste de correlação de Pearson. Como resultados, observou-se que nenhum dos grupos foi capaz de selar completamente a interface da retrocavidade.O tipo de seccionamento apical, de preparo retrocavitário e o material odontológico usado para a retrobturação mostraram-se fatores significantes em algumas combinações (p<0. 05), salientando-se que, em geral, menores valores de infiltração foram observados para a apicectomia a 90º, retrocavitação com retroponta ultra-sônica e quando a retrocavidade foi obturada com MTA. Assim, com base na metodologia empregada, foi possível concluir que as diferentes formas de seccionamento apical, preparo retrocavitário e material odontológico utilizado para a retrobturação influenciam no grau de infiltração, sendo que o material mostrou-se como o fator mais influente, seguido da angulação da apicectomia e do instrumento utilizado na retrocavitação.
222

Avaliação de hipersensibilidade a metais e toxicidade genética associadas ao uso de aparelhos ordotônticos fixos

Westphalen, Graziela Henriques January 2006 (has links)
Made available in DSpace on 2011-12-27T14:14:10Z (GMT). No. of bitstreams: 2 000386676-0.pdf: 3018083 bytes, checksum: d24f83f7441985d1dc1910ac8f3fa8e9 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to evaluate the hypersensitivity to metals and the genetic toxicity associated with the use of fixed orthodontic appliances. Hypersensitivity reactions were verified through the patch test carried out by a dermatologist before and two months after the placement of orthodontic appliances in a group of patients. The genetic toxicity was evaluated by using the micronucleus test and the comet assay. The sample was constituted of cells of the oral epithelium of the patients. For micronucleus test, cells were sampled before and 30 days after the placement of orthodontic appliance. For comet assay, the sample was obtained before and 10 days after the placement of orthodontic appliance. For either the micronucleus test or the comet assay, slides were mounted and processed according to standard protocols and analyzed under light microscope. Statistical analysis was performed by non-parametric tests (Fisher’s Exact Test, McNemar and Wilcoxon) and descriptive analysis. Regarding hypersensitivity, no differences were observed between the reactions before and after placement of the orthodontic appliances, which indicates that they did not sensitize patients. The comet assay showed low DNA damage level either before or after orthodontic appliance placement. Conversely, micronucleus test revealed a significant increase of permanent chromosomal damages in the period of 30 day after the placement of orthodontic appliance. Thus, more studies are still needed to understand the genetic toxicity potential of orthodontic devices, and long term studies of follow-up of the orthodontic patients are suggested. / O objetivo desse estudo foi avaliar a hipersensibilidade a metais e a toxicidade genética associadas ao uso de aparelhos ortodônticos fixos. As reações de hipersensibilidade foram verificadas por análise dermatológica utilizando o teste de contato, antes e dois meses após a montagem do aparelho ortodôntico em um grupo de pacientes. A toxicidade genética foi avaliada pelo teste de micronúcleos e pelo ensaio cometa, a partir de células da mucosa bucal dos pacientes. Para o teste de micronúcleos, as células foram coletadas antes e 30 dias após a montagem do aparelho ortodôntico. Para o ensaio cometa, a amostra foi obtida antes e 10 dias após o início do tratamento ortodôntico. Para os dois testes foram preparadas lâminas, cuja leitura foi realizada em microscópio óptico. Na análise estatística empregaram-se testes não paramétricos (Teste Exato de Fisher, McNemar, Wilcoxon) e análise descritiva. Em relação às reações de hipersensibilidade, não foi observada diferença antes e após a montagem do aparelho ortodôntico, o que indica que os pacientes não foram sensibilizados pelo aparelho. O ensaio cometa mostrou baixos níveis de dano no DNA nas células avaliadas, tanto antes quanto após a montagem do aparelho. No entanto, no teste de micronúcleos foi observado um aumento significativo de danos cromossômicos permanentes no período de trinta dias após a montagem do aparelho ortodôntico. Dessa forma, pesquisas adicionais são necessárias a fim de avaliar o potencial genotóxico dos aparelhos ortodônticos fixos, em associação a estudos de longo prazo de acompanhamento dos pacientes.
223

Expansão rápida maxilar com parafuso convencional e limitador posterior em pacientes com fissura transforame incisivo: alterações verticais e ântero-posteriores

Lanes, Michel Azevedo January 2006 (has links)
Made available in DSpace on 2011-12-27T14:14:12Z (GMT). No. of bitstreams: 2 000386491-0.pdf: 18791773 bytes, checksum: 23dd3e96c1894b6bf14e79ed56a61116 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to evaluate and compare the effects of rapid maxillary expansion (RME) in patients with cleft lip and palate, applying a modified Haas expander with two different types of expanding screws. The sample was composed of 31 individuals with complete cleft lip and palate with mean age of 10. 7 years, presenting maxillary atresia at the anterior region and adequate posterior transverse relationship. Among these, 17 patients were submitted to RME with an expanding screw with posterior stop (LP group) and 14 with a conventional screw (C group). The study comprised analysis of lateral cephalograms before expansion (T1), after expansion (T2), and six months after expansion (T3). The Student’s t test and Friedman test (p≤0. 05) revealed that the maxilla presented downward displacement in both groups and forward displacement in the LP group at T2, which was maintained at T3. Mandibular movement was similar between groups, with downward and backward positioning at T2 and returning to the initial position at T3. The maxillary incisors were extruded in the LP and C groups and presented buccal tipping in the LP group. The maxillary molars in the C group presented extrusion at T2 and returned to the initial position at T3; the C group also presented opening of the occlusal plane, which was reduced at T3. Profile evaluation revealed greater forward soft tissue projection for the LP group. / O objetivo deste estudo foi avaliar e comparar os efeitos da expansão rápida maxilar (ERM) em pacientes com fissura de lábio e palato, utilizando disjuntor de Haas modificado com dois diferentes tipos de parafusos expansores. A amostra constituiu-se de 31 indivíduos portadores de fissura transforame incisivo com idade média de 10,7 anos, que apresentavam atresia maxilar na região anterior e relação transversal posterior correta. Destes, 17 pacientes foram submetidos a ERM com parafuso limitador posterior (Grupo LP) e 14 com parafuso convencional (Grupo C), sendo avaliadas telerradiografias de perfil no período préexpansão (T1), pós-expansão (T2), e seis meses pós-expansão (T3). Através do teste t-student e teste de Friedman (p≤0,05) verificou-se que em ambos os Grupos a maxila movimentou-se para baixo, no Grupo LP também para frente, no período T2 e mantendo-se em T3. A movimentação mandibular foi semelhante entre os Grupos, havendo um posicionamento para baixo e para posterior em T2 retornando para anterior em T3. Os incisivos superiores nos Grupos LP e C extruíram e no Grupo LP sofreram vestibularização no período de T2, mantendose em T3. Os molares superiores no Grupo Convencional sofreram extrusão em T2 e retornaram a posição inicial em T3 e houve uma abertura do plano oclusal no Grupo Convencional, que foi reduzida em T3. Na avaliação do perfil observou-se uma maior projeção dos tecidos moles para anterior no Grupo LP.
224

Análise comparativa do desajuste marginal de infra-estruturas de prótese fixa pilares micro-unit com o uso de retificadores manuais

Alonso, Fernando Rizzo January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:13Z (GMT). No. of bitstreams: 2 000399361-0.pdf: 8314993 bytes, checksum: a3c46db6ec5de11b04392bd9c5ca0dce (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The percentage of new bone formation was greater in the LLLT group (57. 89%) than in the control group (46. 75%) (p=0. 006). The analysis of chemical composition and of Ca and P ratios showed greater mineralization in the LLLT group. Crystallinity percentages were greater in rabbits in the LLLT group. Diffractograms showed that crystalline structures were similar to hydroxyapatite. Results showed that LLLT had a positive effect on the percentage of new bone formation and on the chemical composition and crystallinity of the DO site. The DO site regeneration was confirmed by the detection of hydroxyapatite in the crystalline structure. The percentage of new bone formation was greater in the LLLT group (57. 89%) than in the control group (46. 75%) (p=0. 006). The analysis of chemical composition and of Ca and P ratios showed greater mineralization in the LLLT group. Crystallinity percentages were greater in rabbits in the LLLT group. Diffractograms showed that crystalline structures were similar to hydroxyapatite. Results showed that LLLT had a positive effect on the percentage of new bone formation and on the chemical composition and crystallinity of the DO site. The DO site regeneration was confirmed by the detection of hydroxyapatite in the crystalline structure. / O crescente uso das próteses implanto-suportadas aumentou a preocupação com a precisão de adaptação, já que a adaptação passiva é um dos fatores fundamentais para o sucesso longitudinal dessas reabilitações protéticas. O objetivo deste trabalho foi avaliar o desajuste marginal de infra-estruturas metálicas de prótese fixa sobre implantes, antes a após a retificação manual, como o teste do parafuso único, utilizando como grupo controle cilindros pré-usinados. Foram confeccionadas 10 infra-estruturas em liga de cobalto-cromo (Co-Cr), simulando uma prótese fixa de três elementos sobre dois implantes. Para isso, utilizou-se uma matriz metálica simulando a disposição clínica de implantes osseointegrados na região dos dentes 14 e 16, contendo pilares Micro-Unit. Cinco infra-estruturas foram confeccionadas com cilindros pré-usinados. As outras cinco foram confeccionadas com cilindros calcináveis, que após avaliação inicial, sofrem retificação manual das bordas de assentamento do cilindro após fundição, formando o terceiro grupo. Todas as infra-estruturas receberam soldagem a laser. As leituras do desajuste marginal foram realizadas através de imagens do microscópio eletrônico de varredura, utilizando a técnica do parafuso único, totalizando 25 medições em cada cilindro. As médias de desajuste marginal de cada cilindro foram utilizadas para a análise estatística. A análise de variância com nível de significância de 5% foi utilizada para avaliar o efeito da retificação manual entre os três grupos testados, nos cilindros com e sem parafuso. Foi concluído que os procedimentos de retificação manual não alteraram significativamente os valores de desajuste marginal nas infra-estruturas fundidas em Co-Cr, ou seja, não aumentaram a passividade das peças protéticas sobre os pilares.
225

Avaliação da carga inorgânica de resinas compostas de conteúdo nanométrico

Hörlle, Lucas January 2009 (has links)
Made available in DSpace on 2011-12-27T14:14:14Z (GMT). No. of bitstreams: 2 000418300-0.pdf: 3151523 bytes, checksum: aeea57ce4111e17b6c94b365bb2412d1 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The purpose of this study was to analyse the filler content of composites resins with nanomeric content. It was determined the filler weight content into each material (TGA); inorganic filler by scanning-electron microscopy (SEM), their dimensions and morphology; besides weight compounds with energy dispersed X – ray test. The composites Esthet X, Filtek Supreme XT and Grandio were divided in six groups according their commercial mark and color. Filler content´s values varied from 75,75 to 87 Wt%, to Esthet X D group and Grandio E group, respectively. To EDX test, O and Si elements were observed in all of groups. Al was observed into the composites Esthet X and Grandio groups and Ba was not observed in groups of Grandio E, Filtek Supreme E and Filtek Supreme D. The results obtained about means values (μm) were: Esthet X E – 1,16B; Esthet X D – 1,39B; Filtek Supreme E – 0,6B; Filtek Supreme D – 1,14AB; Grandio E – 2,05AB e Grandio D – 3,1A. At the morphology of particles analyses, the composites resins Esthet X and Grandio showed similar characteristics with a high quantity of irregular inorganic particles and heterogeneous morphology. In the other hand, the groups of Filtek Supreme XT composites presented different characteristics among the other groups and similar into their own groups. These groups showed a high quantity of spherical and regular particles, with homogeneous distribution and sizes. The results presented different inorganic particles morphology and sizes, independent of the type of the composite. It could be concluded that composite resins presented physical characteristics of shape and size of inorganic particles that is not always coincident with manufacturer and literature. / O objetivo deste estudo foi analisar a carga inorgânica de resinas compostas de conteúdo nanométrico. Foi determinando o conteúdo de carga em peso incorporado a cada material (TGA), o conteúdo inorgânico através da microscopia eletrônica de varredura (MEV), suas dimensões e morfologia, além dos componentes em peso pelo teste de Espectrografia por Dispersão de Raios X (EDS). As resinas compostas Esthet X, Filtek Supreme XT e Grandio foram divididas em seis grupos de acordo com a marca da resina composta e a cor. Os valores do conteúdo de carga variaram de 75,75 a 87 Wt% para o grupo Esthet X D e o grupo Grandio E, respectivamente. À análise por EDS, os elementos O e Si foram observados em todos os grupos. Al foi observado nos grupos das resinas compostas Esthet X e Grandio e Ba não foi observado nos grupos Grandio E, Filtek Supreme E e Filtek Supreme D. Os resultados obtidos sobre os valores médios (μm) foram: Esthet X E – 1,16в; Esthet X D – 1,39в; Filtek Supreme E – 0,6в; Filtek Supreme D – 1,14в; Grandio E – 2,05Aв e Grandio D – 3,1A. Na análise da morfologia das partículas, as resinas compostas Esthet X e Grandio apresentaram características semelhantes entre si com grande quantidade de partículas de carga inorgânica irregulares, de morfologia heterogênea. Por outro lado, os grupos da resina Filtek Supreme XT apresentaram características diferentes das demais e semelhantes entre si, quanto à morfologia. Evidenciaram grande quantidade de partículas de carga inorgânica esféricas, regulares, com distribuição e tamanho homogêneos. Os resultados mostraram diferentes formas e tamanhos de partículas inorgânicas, independente do tipo de resina composta. Pôde-se concluir que as resinas compostas apresentaram características físicas de forma e tamanho das partículas de carga inorgânica nem sempre coincidindo com as apresentadas pelos fabricantes e comprovada pela literatura.
226

Comparação de propriedades mecânicas e do conteúdo de carga de cinco resinas compostas com nanopartículas

Pires, Luiz Antonio Gaieski January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:19Z (GMT). No. of bitstreams: 2 000402875-0.pdf: 1268537 bytes, checksum: d69e79b0f145ba87098e8a6bb0aa9e58 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aims of this study were evaluate and compare selected mechanical properties (diametral tensile strength and microhardness) and filler content of five current composites in A2 enamel and dentin shades. The tested composites were: 4Seasons (4S), Ivoclar Vivadent; Esthet-X improved (EX), Dentsply; Filtek Supreme (SU), 3MESPE; Grandio (GR), Voco and Palfique Estelite (PE), Tokuyama Dental Corp. For each group, diametral tensile strength (n=10), Knoop microharndess (n=10) and the weigth filler content were recorded. The amount of filler was obtained by termogravimetric analysis (TGA). Data were compared statistically with ANOVA and Tukey (a = 0. 05). The averages for diametral tensile strength (MPa) were: 4S dentin 36. 08b and 4S enamel 39. 26 ab ; EX dentin 44. 44 ab and EX enamel 45. 12 ab; GR dentin 45. 23 ab and GR enamel 49. 24 a ; SU dentin 46. 86 ab and SU enamel 48. 25 ab ; PE dentin 38. 69 ab ; PE enamel 38. 58 ab (p < 0. 05). The averages for Knoop microhardness (KHN) were: 4S dentin 61. 6b and 4S enamel 57. 98b ; EX dentin 73. 6b and EX enamel 54. 45b; GR dentin 123. 90a and GR enamel 74. 89b ; SU dentin 101. 30a and SU enamel 123. 10a ; PE dentin 55. 9b ; PE enamel 61. 70b (p < 0. 05). For weigth filler content (wt%): 4S dentin 75. 84 and 4S enamel 76. 37 ; EX dentin 76. 80 and EX enamel 75. 75 ; GR dentin 86. 89 and GR enamel 87. 00 ; SU dentin 76. 22 and SU enamel 76. 54 ; PE dentin 71. 62; PE enamel 70. 56.There was statistical difference between the composites within the different testes (p < 0. 05). The tested composites had not similar behavior for diametral tensile strength and Knoop microhardness. Significant differences were not observed when enamel and dentin shades were compared although Grandio in microhardness test. The highest diametral tensile strength was recorded to Grandio enamel and 4 Seasons dentin showed the lowest average (p < 0. 05). For Knoop microhardness, Filtek Supreme in both shades sowed the highest averages in comparison to other groups (p < 0. 05). / O objetivo deste estudo foi avaliar e comparar as propriedades mecânicas selecionadas (resistência à tração diametral, microdureza Knoop) e conteúdo de carga em peso pela análise termogravimétrica (TGA) de cinco marcas comerciais de resina composta diferentes em matriz orgânica e carga nas cores A2 esmalte e dentina: 4Seasons (4S), Ivoclar Vivadent; Esthet-X improved (EX), Dentsply; Filtek Supreme (SU), 3MESPE; Grandio (GR), Voco e Palfique Estelite (PE), Tokuyama Dental Corp. Para cada grupo, a resistência à tração diametral (n=10), a microdureza Knoop (n=10) e o conteúdo de carga em peso pela análise termogravimétrica foram determinados. Os resultados obtidos nos ensaios foram comparados estatisticamente com análise de variância e Tukey (J = 0,05). As médias obtidas para resistência à tração diametral (MPa) foram: 4S dentina 36,08 b e 4S esmalte 39,26 ab ; EX dentina 44,44 ab e EX esmalte 45,12 ab ; GR dentina 45,23 ab e GR esmalte 49,24 a ; SU dentina 46,86 ab e SU esmalte 48,25 ab ; PE dentina 38,69 ab ; PE esmalte 38,58 ab (p < 0,05). As médias obtidas para microdureza Knoop (KHN) foram: 4S dentina 61,6b e 4S esmalte 57,98b; EX dentina 73,6b e EX esmalte 54,45b; GR dentina 123,90a e GR esmalte 74,89b ; SU dentina 101,30a e SU esmalte 123,10a ; PE dentina 55,89b ; PE esmalte 61,70b (p < 0,05). Para o conteúdo de carga em peso (wt%): 4S dentina 75,84 e 4S esmalte 76,37; EX dentina 76,80 e EX esmalte 75,75 ; GR dentina 86,89 e GR esmalte 87,00 ; SU dentina 76,22 e SU esmalte 76,54 ; PE dentina 71,62; PE esmalte 70,56. Os compósitos testados não apresentaram comportamento mecânico similar quanto à resistência à tração diametral e microdureza Knoop.Não foi observada diferença quando as pastas esmalte e dentina foram comparadas com exceção da resina Grandio no teste de microdureza. A maior resistência à tração diametral foi observada para a Grandio esmalte enquanto a 4 Seasons dentina apresentou a mais baixa média (p < 0,05). No teste de microdureza Knoop, a resina Filtek Supreme em ambas as pastas e a Grandio dentina apresentaram as maiores médias em comparação aos demais grupos (p < 0,05).
227

Análise local e sistêmica das reações tissulares a diferentes materiais utilizados em pulpotomias: estudo em ratos

Follmann, Carina Staudt January 2011 (has links)
Made available in DSpace on 2011-12-27T14:14:19Z (GMT). No. of bitstreams: 2 000434141-0.pdf: 4096445 bytes, checksum: 46ea01752aceb50c79baf98a79715628 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Introduction: The aim of this study was to evaluate the subcutaneous connective tissue reaction and the organs liver and kidney to mineral trioxide aggregate (MTA), paste of calcium hidroxyde (CH) and formocresol (FC). Methods: Polyethylene tubes containing the test materials and empty tubes (control group) were implanted in the subcutaneous tissue of 46 rats. After 7 and 21 days, observations on back were made for inflammatory alterations, fibrous condensation, abscess formation and foreign body, and, on liver and kidney, were made for steatosis, apoptosis, inflammation, vascular changes and hipercellularity. Comparisons between groups and periods of time were made using the Kruskal-Wallis, Post-hoc and Mann- Whitney tests. Results: MTA and CH groups showed a behavior similar in inflammatory alterations to that of the control group in 21days, in contrast of FC group that presented statistically significant difference to that of other groups. In FC group, there was no formation of fibrous capsule and formation of abscess, in 21 days. In all groups, alterations in liver and kidney were observed. Conclusion: MTA and CH groups showed a behavior similar in all evaluated events. FC group presented unfavorable results. Tissue alterations were observed in liver and kidney. / Introdução : O objetivo deste estudo foi avaliar, em ratos, a reação do tecido conjuntivo subcutâneo, e dos órgãos fígado e rim, a materiais utilizados em pulpotomias: agregado trióxido mineral (MTA), pasta de hidróxido de cálcio (HC) e formocresol (FC). Métodos: Tubos de polietileno vazios (grupo controle) e contendo os materiais de teste foram implantados no tecido subcutâneo de 46 ratos. Após 7 e 21 dias, as observações no dorso foram feitas para alterações inflamatórias, condensação fibrosa, formação de abscesso e corpo estranho e, no fígado e rim, foram avaliadas esteatose, apoptose, inflamação, alterações vasculares e hipercelularidade. Comparações entre os grupos e períodos de tempo foram feitas usando o teste de Kruskal-Wallis, Post-hoc e Mann-Whitney. Resultados: Os grupos MTA e HC mostraram um comportamento semelhante ao do grupo controle, nas alterações inflamatórias em 21 dias, ao contrário do grupo FC, o qual apresentou diferença estatisticamente significante em relação aos outros grupos. No grupo FC, não houve formação de cápsula fribrosa e houve formação de abscesso, em 21 dias. Em todos grupos, alterações no fígado e rim foram observadas. Conclusão: Os grupos MTA e HC mostraram um comportamento similar em todos os eventos analisados. O grupo FC apresentou resultados não favoráveis. Foram observadas alterações tissulares no fígado e rim.
228

Análise comparativa da precisão de adaptação entre componentes UCLA e implante de um mesmo sistema

Bondan, João Lopes January 2007 (has links)
Made available in DSpace on 2011-12-27T14:14:20Z (GMT). No. of bitstreams: 2 000390167-0.pdf: 8479233 bytes, checksum: 78f267d7711851d94f32594d0a86c23d (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to evaluate the fit between the components UCLA and implant of the same system (Neodent). The comparison was made through an evaluation of the vertical and horizontal gaps present at the interface between implant and UCLA, through scanning electronic microscopy (SEM), measurements in selected locations. Statistical analysis was done through variance analysis procedure (Anova-Oneway) and Tukey´s posterior procedure, with a significance level of 5%. The results pointed the UCLA components present significant differences in many evaluated aspects. Such differences might have some influence in the use of these components, both in clinical results and in its predictability. / O objetivo deste estudo foi avaliar a precisão de adaptação entre componentes UCLA e implante de um mesmo sistema (Neodent). A análise foi através da avaliação da fenda vertical e da discrepância horizontal da interface implante-UCLA por microscopia eletrônica de varredura (MEV), das mensurações em locais indicados. Para a comparação dos resultados, foi utilizado o procedimento de análise de variância (Anova-Oneway) e o procedimento posterior de Tukey, ao nível de significância de 5%. Os resultados mostraram que os componentes UCLA avaliados possuem diferenças significantes em diversos pontos avaliados. Essa variabilidade nos resultados podem interferir na eficácia de uso desses componentes, nos resultados clínicos e na sua previsibilidade.
229

Avaliação da citotoxicidade e da liberação iônica de mini-implantes ortodônticos

Blaya, Micéli Beck Guimarães January 2010 (has links)
Made available in DSpace on 2011-12-27T14:14:23Z (GMT). No. of bitstreams: 2 000419964-0.pdf: 1028721 bytes, checksum: 6c934b5641f1910681c7e4e7f278caa4 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to investigate the biocompatibility of new and corroded miniscrews (MSs) through the evaluation of cell toxicity in vitro and of ion release in vivo. Saccharomyces Cerevisiae yeast was used as a eukaryotic microbiological model for the cytotoxicity assay. Qualitative and quantitative tests were carried out using the wild strain FF18733. In addition, direct exposure (in liquid YPD culture) and indirect exposure tests (using artificial saliva previously exposed to the MSs) were carried out using new MSs and MSs with sodium fluoride (NaF at 0. 0125%, 0. 025% and 0. 05%) and used in vivo. Photomicrographs with scanning electron microscopy (SEM) were obtained for the new and used MSs. As a result, the wild strain FF 18733 showed a reduction in cell viability in the direct exposure to one and two new MSs. However, this reduction was not significant. The results for indirect exposure showed that there were no significant differences between new and used MSs and the control groups. Moreover, exposure to NaF did not induce corrosion of MSs sufficient to lead to significant cell toxicity in the yeast. Despite the slight corrosion revealed by the photomicrographs, there was no significant loss of cell viability in the strains of S. cerevisiae tested. This demonstrates that the components of MSs (Ti-6Al-4V) did not significantly alter the yeast metabolism, indicating that the MSs tested present good biocompatibility for use in orthodontic clinics. The aim of the in situ study was to compare the levels of several metallic ions released in the saliva of patients undergoing orthodontic treatment with MSs. The experimental group was made up of 20 individuals who were within the 6th and 8th months of treatment. Saliva from each patient was collected at four different timepoints: before MS placement (T1), 10 minutes (T2), 7 days (T3) and 30 days (T4) after MS placement. Saliva samples were analyzed by spectrometry (ICP- MS - inductively coupled plasma mass spectrometry; and ICP-OES - inductively coupled plasma optical emission spectrometry).The release of nine different metal ions was observed: titanium (Ti), zinc (Zn), chromium (Cr), nickel (Ni), iron (Fe), copper (Cu), aluminum (Al), vanadium (V), and cobalt (Co). Data were analyzed by descriptive statistics and tests for normality (Shapiro-Wilk). The metal ion concentrations in the saliva at the four different timepoints were compared using the Wilcoxon test (α=95%). At T4, there was a quantitative increase in the salivary concentration of Cu, Ti, V and Zn and a quantitative decrease in Al, Co, Cr, Fe and Ni, when compared to T1. However, there were no statistically significant differences in the metal concentrations. Therefore, it can be concluded that the use of orthodontic appliances with MSs does not lead to an increase, significative statistically, in salivary metal concentrations. / Propôs-se neste trabalho avaliar a biocompatibilidade dos mini-implantes ortodônticos novos e utilizados em tratamento ortodôntico por meio da aplicação de testes avaliativos de toxicidade celular in vitro e de liberação iônica in vivo. O ensaio de citotoxicidade foi através da levedura Saccharomyces Cerevisiae que é um modelo microbiológico eucariótico. Foram realizados testes qualitativos e quantitativos, com a cepa selvagem FF18733 desta levedura. Foram executados testes de exposição direta (em meio de cultura YPD líquido) e testes de exposição indireta utilizando: MIs novos, MIs expostos ao fluoreto de sódio (NaF a 0,0125%, 0,025% e 0,05%), e MIs utilizados in vivo. Foram realizadas fotomicrografias com microscopia eletrônica de varredura (MEV) nos MIs utilizados in vivo e novos. Como resultado, a cepa selvagem FF 18733 mostrou uma diminuição de sua sobrevivência nos experimentos de exposição direta a um e a dois mini-implantes novos. No entanto, tal sensibilidade não se mostrou significativa. Os resultados de exposição à saliva artificial de novos, bem como todos os resultados referentes aos usados, não indicaram diferenças em relação aos controles. Da mesma forma, a exposição ao NaF não induziu, nos MIs, uma corrosão suficiente para causar toxicidade celular significativa nesta levedura. Apesar da corrosão leve apresentada nas fotomicrografias, não foram observadas induções de perda de viabilidade celular significativas na cepa testada de S. cerevisiae a partir dos componentes da liga (Ti-6Al-4V) dos MIs ortodônticos. Evidenciou-se, assim, que tais componentes não alteram de forma importante o metabolismo da levedura, indicando que os MIs testados tendem a apresentar uma boa biocompatibilidade para uso em clínica ortodôntica. No estudo in situ, o objetivo foi examinar e comparar os níveis de vários íons metálicos liberados na saliva de pacientes em tratamento ortodôntico e que iriam necessitar de tratamento envolvendo o uso de miniimplante. A amostra foi composta por 20 indivíduos que estavam entre o sexto e o oitavo mês de tratamento ortodôntico. A saliva de cada paciente foi coletada em 4 tempos diferentes: antes da inserção do MI (T1), 10 minutos (T2), 7 dias (T3) e 30 dias (T4) após a instalação do MI. As amostras salivares foram analisadas através de espectrometria (ICP- MS - inductively coupled plasma mass spectrometry; e ICP-OES - inductively coupled plasma optical emission spectrometry). A liberação de nove diferentes ions metálicos foram observados: titânio (Ti), zinco (Zn), cromo (Cr), níquel (Ni), ferro (Fe), cobre (Cu), alumínio (Al) e cobalto (Co). Os dados foram analisados através de estatística descritiva e testes de normalidade (Shapiro-Wilk). A concentração de ions metálicos na saliva nos quatro tempos diferentes de tratamento com MI foi comparado usando o teste de Wilcoxon (α=95%). No tempo T4, houve um aumento quantitativo na concentração salivar de Cu, Ti, V, Zn, bem como um decréscimo quantitativo na concentração salivar de Al, Co, Cr, Fe, Ni, quanto comparados ao grupo T1. No entanto, não houve diferenças estatisticamente significativas entre as concentrações de metais. Logo, pode ser concluído que a colocação de aparelho ortodôntico associado ao uso de mini-implante ortodôntico não leva a um aumento, estatisticamente significativo, na concentração de ions metálicos na saliva.
230

Avaliação da aplicação de uma solução ácida experimental na resistência de união de sistemas adesivos

Melara, Rafael January 2010 (has links)
Made available in DSpace on 2011-12-27T14:14:28Z (GMT). No. of bitstreams: 2 000430098-0.pdf: 130972 bytes, checksum: 7163cf89fa076e570e8462a27723ebe0 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This study aimed to evaluate, in vitro, the bond strength of adhesive systems Adper Scotchbond SE (3M/ESPE) and Adper Scotchbond Multi-Purpose (3M/ESPE) to dentin treated or not with an experimental acid solution. The occlusal surface of twenty sound human molars was removed to obtain a flat dentin area. The teeth were divided into four groups according to the type of adhesive system used and whether the experimental solution was used or not. In groups Adper Scotchbond SE Control and Scotchbond Multi-Purpose Control, the adhesive system was applied according to the manufacturer's instructions. In group Adper Scotchbond SE Experimental, an experimental solution was applied previously to the adhesive system, and in group Adper Scotchbond Multi¬Purpose Experimental, the phosphoric acid 37% was replaced by the application of experimental solution. After applying the adhesive system, a block of composite resin (Z350 - 3M/ESPE), with approximately 6 mm in height was made. After, the teeth were stored in distilled water for 24 h in a culture oven at 37°C. Thereafter, the teeth were sectioned in the direction "x" and "y" to obtain sticks with adhesive area of approximately 1. 0 mm2. Sixteen sticks by group were tested in a microtensile testing machine (EMIC DL-2000) at a speed of 0. 5 mm/min. After the microtensile test, the sticks were evaluated by SEM, to establish the predominant pattern of failure by fractography. According to the analysis of variance two-way there was no statistically significant difference in bond strength values among the four groups. The predominant type of failure observed in SEM was cohesive in the adhesive, followed by cohesive in the hybrid layer. SEM analysis showed that the experimental solution was able to remove the smear layer exposing dentin tubules. Based on these results we conclude that the use of experimental solution in combination with the adhesive systems was able to promote values of bond strength similar to the technique of application as recommended by the manufacturers, and this experimental acid solution was able to obtain a conditioning of dentin surface similar to that obtained with 37% phosphoric acid. / Este estudo teve por objetivo avaliar, in vitro, a resistência de união dos sistemas adesivos Adper Scotchbond SE (3M/ESPE) e Adper Scotchbond Multi-Uso (3M/ESPE) à superfície dentinária tratada ou não com uma solução ácida experimental. A superfície oclusal de vinte terceiros molares humanos hígidos foi removida para a obtenção de uma área plana de dentina. Os dentes foram divididos em 4 grupos, de acordo com o tipo de sistema adesivo usado e aplicação ou não da solução experimental. Nos grupos Adper Scotchbond SE Controle e Adper Scotchbond Multi-Uso Controle, o sistema adesivo foi aplicado de acordo com as instruções do fabricante. No grupo Adper Scotchbond SE Experimental foi aplicada a solução experimental previamente ao sistema adesivo, e no grupo Adper Scotchbond Multi-Uso Experimental, o condicionamento com ácido fosfórico a 37% foi substituído pela aplicação da solução experimental. Após a aplicação do sistema adesivo, um bloco de resina composta (Z350 - 3M/ESPE), com aproximadamente 6 mm de altura, foi confeccionado, sendo os dentes armazenados em água destilada por 24 h em uma estufa de cultura a 37°C. Decorrido este período, os dentes foram seccionados nos sentido “x” e “y” a fim de obter palitos com área adesiva de aproximadamente 1,0 mm2. Dezesseis palitos por grupo foram submetidos ao teste de microtração em uma máquina de ensaios (EMIC DL-2000), a uma velocidade de 0,5 mm/min. Após o teste de microtração, os palitos foram avaliados em microscopia eletrônica de varredura, para estabelecimento do padrão predominante de falha, por meio de fractografia. De acordo com a análise de variância segundo duas vias não houve diferença estatisticamente significativa nos valores de resistência de união entre os quatro grupos, para os fatores adesivos e tratamentos de superfície. O tipo de falha predominante observado em MEV foi coesiva em adesivo, seguido de coesiva em camada híbrida.A análise em MEV mostrou que a solução experimental foi capaz de remover a smear layer expondo túbulos dentinários. Com base nos resultados encontrados é possível concluir que o uso da solução experimental contendo um inibidor de metaloproteinases, em associação aos sistemas adesivos estudados, foi capaz de promover valores de resistência de união 3 semelhantes à técnica de aplicação recomendada pelos fabricantes; e que essa solução ácida experimental foi capaz de obter um padrão de condicionamento de superfície dentinária semelhante ao obtido com o ácido fosfórico a 37%.

Page generated in 0.4368 seconds