• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 907
  • 81
  • 78
  • 78
  • 78
  • 68
  • 7
  • 7
  • 6
  • 6
  • 4
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 922
  • 922
  • 454
  • 392
  • 234
  • 208
  • 160
  • 149
  • 100
  • 97
  • 81
  • 69
  • 69
  • 69
  • 66
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Protocolo para sinterização de zircônia odontológica por energia de micro-ondas

Barchetta, Nayara Fernanda [UNESP] 02 December 2015 (has links) (PDF)
Made available in DSpace on 2016-04-01T17:54:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-12-02. Added 1 bitstream(s) on 2016-04-01T18:00:20Z : No. of bitstreams: 1 000860669.pdf: 1619756 bytes, checksum: d093d0ff7dd919a21eba0a48092b8fbe (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho teve como objetivo avaliar o impacto da temperatura de sinterização e resfriamento, no comportamento mecânico e microestrutural da cerâmica odontológica Y-TZP, sinterizada por energia de micro-ondas. Variaram-se a temperatura de sinterização e resfriamento a fim de se desenvolver um protocolo, que mantenha a microestrutura da zircônia compatível à obtida com sinterização convencional. Dessa forma, buscou-se otimizar o processo fazendo uso das principais vantagens da energia de micro-ondas: economia de energia, tempo de processo reduzido e absorção volumétrica de energia pelo material. Foram confeccionados N=84 discos por meio de CAD-CAM para obter padronização no tamanho dos discos de acordo com a ISO 6872, os discos foram divididos em 7 grupos n=12, o Grupo Controle foi sinterizado de modo convencional, e os Grupos Experimentais foram sinterizados por energia de micro-ondas, nos quais variaram-se a temperatura de sinterização (S) e a temperatura de resfriamento (R), formando os grupos: S1400RR, S1400R400, S1400R25, S1450RR, S1450R400 e S1450R25. Para caracterização microestrutural foram realizadas medidas de densidade, análises de difração de raios-X (DRX), microscopia eletrônica de varredura (MEV) e tamanho de grãos. A caracterização mecânica foi realizada por meio de ensaios de resistência à flexão biaxial. Os resultados de resistência à flexão obtidos foram analisados estatisticamente (ANOVA, Tukey, Sidak e Dunnett), sendo que os Grupos Controle (806,1±105,8 MPa) e S1450 (824,7±99,12 MPa) não se diferenciaram. Somente os Grupos sinterizados à 1400 °C (681,9±91,17 MPa) apresentaram médias inferiores. Este mesmo fato ocorreu quando se analisou a densidade. A análise de DRX mostrou que a fase tetragonal prevaleceu em todos os grupos. Pode-se então, sugerir um protocolo ideal para sinterização de Y-TZP por energia de micro-ondas:... / This study aimed to evaluate the impact of sintering and cooling temperatures in the mechanical and microstructural behavior of microwave-sintered Y-TZP ceramics. The sintering and cooling temperatures were varied at given range in order to develop a protocol, which could maintain the zirconia microstructure compatible to the one obtained by conventional sintering. Thus, in this study the sintering process was optimized with the use of the main microwave energy qualities: energy-saving, reduced processing time and volumetric energy absorption by the material. Eighty-four discs were prepared with CAD-CAM (n=84) for discs size standardization, following ISO 6872. The discs were distributed into 7 groups (n=12), Control Group = conventional sintering. Other Groups, with microwave-sintered discs, with variations in sintering (S) and cooling (R) temperatures, formed the following sub-groups: S1400RR, S1400R400, S1400R25, S1450RR, S1450R400 and S1450R25. For microstructural analysis, the following characterizations were performed: Density, XRD and SEM; mechanical analysis was performed via biaxial flexure resistance. The flexure resistance data were statistically analyzed (two-way ANOVA, Tukey, Sidak and Dunnett). The Control (806,1±105,8 MPa) and S1450 (824,7±99,12 MPa) Groups did not present differences; only discs from Groups sintered at 1400ºC (681,9±91,17 MPa) showed lower averages. The same occurred when density values were analyzed. From XRD analysis, it was observed that all groups had remained in the tetragonal phase for a larger period. In conclusion, it can be proposed a protocol for microwave sintering: temperature 1450 ° C for 15 min and fast cooling. The method of microwave sintering presents compatibility with the conventional method and allows process optimization
172

Avaliação da microdureza de quatro cimentos resinosos duais fotopolimerizados através da interposição de diferentes materiais: estudo in vitro

Umetsubo, Luzia Sakaguti [UNESP] 16 July 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-07-16Bitstream added on 2014-06-13T21:02:26Z : No. of bitstreams: 1 umetsubo_ls_dr_sjc.pdf: 496272 bytes, checksum: a357a92f3b43c76cc064965c3de92548 (MD5) / Este estudo avaliou por testes de microdureza o grau de polimerização de quatro cimentos resinosos duais: Bistite II, Enforce, RelyX ARC e Variolink II, fotopolimerizados através da interposição de barreiras confeccionadas com materiais utilizados em retaurações estéticas indiretas. Foram confeccionados 72 espécimes para cada marca de cimento, divididos em 6 grupos, segundo o tipo de barreira utilizada na interposição, durante a sua fotopolimerização: G1: sem barreira; G2: Resina composta Cesead; G3: Inceram alumina/Allceram; G4: IPS Empress; G5: Inceram zirconia/Allceram; G6: fragmento dental. A fotopolimerização foi realizada com luz halógena Optilux 401 (Demetron) com 650 mW/cm2 de potência e os ensaios foram realizados em três períodos: imediata, 24h e 7dias, em um Microhardness Tester FM 700, sob cargas de 50gf durante 15s, cujos valores de microdureza foram obtidos em HV. As médias dos valores em HV foram submetidos à ANOVA e teste de Tukey. As condições de G3 e G5 resultaram em polimerização deficiente do cimento, que não permitiram a realização dos ensaios. O cimento Bistite teve a maior dureza no grupo controle e o menor com a interposição de resina composta. O RelyX ARC teve os valores de microdureza mais estáveis nas condições analisadas em todos os períodos de avaliação. O Enforce e o Variolink foram intermediários e semelhantes entre si. A interposição de materiais durante a fotopolimerização de cimentos resinosos duais, interfere na microdureza dos mesmos. Quando da utilização de alumina ou zirconia, outro modo de polimerização ou tipo de cimento deve ser utilizado. / This study evaluated by microhardness tests the curing degree of four dual cured cements: Bistite II, Enforce, RelyX ARC and Variolink II, lightcured through the interference of barriers made with materials used in indirect aesthetic restorations. 72 specimens were made for each cement that was divided into 6 groups, according to the barrier type used in the interference, during the light activation G1: without barrier; G2: Cesead, a composed resin; G3: Inceram alumina/Allceram; G4: IPS Empress; G5: Inceram zirconia/Allceram; G6: dental fragment. The lightcuring was accomplished with a conventional halogen unit, Optilux 401 (Demetron) with 650 mW/cm2 and the measurements were accomplished in three periods: immediate, 24hours and 7days, in a Microhardness Tester FM 700, under loads of 50gf during 15seconds. Microhardness values were obtained in HV. The averages of the HV values were submitted to ANOVA and Tukey test. The G3 and G5 groups resulted in deficient polymerization of the cement, that they didn't allow the accomplishment of the rehearsals. The Bistite cement had the largest hardness in the control group and the smallest with the interference of Cesead. RelyX ARC had the stableer values of microhardness in the analyzed conditions in all of the evaluation periods. Enforce and Variolink were intermediate and similar amongst them. The interference of barriers during the lightcuring of dual resinous cements interferes in the microhardness of the same ones. When a restoration of alumina or zirconia is used, other polymerization way or cement type should be used.
173

Citotoxicidade, genotoxicidade e expressão gênica em células da polpa dental humana sensibilizadas por cimentos endodônticos

Rabelo, Sylvia Bicalho [UNESP] 14 September 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-09-14Bitstream added on 2014-06-13T19:41:51Z : No. of bitstreams: 1 rabelo_sb_dr_sjc.pdf: 891440 bytes, checksum: ccb82a07266cfe393903fec2e52c87af (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O sucesso dos tratamentos endodônticos está relacionado ao correto diagnóstico das alterações pulpares, à qualidade do preparo biomecânico e da obturação dos canais radiculares, bem como à compatibilidade entre os cimentos obturadores com os tecidos adjacentes ao canal. Atualmente a busca de bom comportamento biológico destes cimentos se faz de extrema importância. O presente estudo teve como objetivo analisar a citotoxicidade e a genotoxicidade dos extratos de três cimentos endodônticos e seus efeitos sobre a expressão dos genes BMP2, ALP, RUNX2, BGLAP, OPN e DMP1 em células da polpa dental humana. Foram utilizadas células primárias de tecidos pulpares de terceiro molar com rizogênese incompleta. Cimentos endodônticos foram depositados em placas de 24 poços e armazenados a 37°C por 6 h; cada espécime foi colocado em contato com 2,7 ml de meio de cultura (DMEM-F12) e as amostras foram incubadas por 24 h, a 37°C. Extratos originais (1:1) de cada material foram diluídos em série até 1:32 e analisados quanto a citotoxicidade pelo ensaio de MTT. Após a obtenção de uma diluição que não fosse extremamente tóxica e não interferisse demasiadamente na replicação celular (subdose), foi realizado o teste de micronúcleo para avaliação da genotoxicidade dos materiais. A expressão dos genes foi verificada por RT-PCR em tempo real, em 6, 12 e 24 h. O RNA total foi isolado e retrotranscrito. Os testes de citotoxicidade indicaram que a sobrevivência celular foi afetada pelos extratos na seguinte ordem: EndoREZ > AH Plus > RoekoSeal ≥ MTA. O EndoREZ propiciou o maior número de micronúleos no ensaio de genotoxicidade. A quantificação relativa indicou que em 24 h, o AH Plus e o EndoREZ agiram de modo similar, aumentando a expressão da OPN e reduzindo a ALP; o RoekoSeal gerou expressão da OPN... / The success of endodontic therapy is related to the correct pulp and periapical alterations diagnosis; to the good biomechanical instrumentation and to the root canal sealing quality; to the compatibility between the endodontic sealers and the root canal surrounding tissues as well. Nowadays, the seeking for a sealer with good biological behavior is extremely important. The aim of this study was to analyze the cytotoxicity and the genotoxicity of three endodontic sealers and their effects on the expression of the genes BMP-2, ALP, RUNX2, BGLAP, SPP1 and DMP1 in human dental pulp cells. Primary cells from the 5th passage obtained from pulp tissue of third molar with incomplete rizogenesis were used in this study. Endodontic sealers were placed in 24 well plates and stored at 37°C for 6 hours. After that, each specimen was covered with 2.7 ml of cell culture media (DMEM-F12) and incubated afterwards at 37°C for 24 h. Original extracts (1:1) of each material were serially diluted up to 1:32 and the citotoxicity was analyzed by MTT assay. After obtaining extracts subdose, non very toxic or non interfering on cell replication, genotoxicity was evaluated by micronucleus test. The gene expression was accessed by Real Time RT-PCR, after extracts exposure of 6, 12 and 24 h. Total RNA was isolate and retrotranscribed. The citotoxicity test has showed that cell survival was affected in the following order: EndoREZ > AH Plus > Roeko Seal ≥ MTA. EndoREZ has caused the highest score in micronucleus assay. Relative quantification indicated that at 24 h, AH Plus and EndoREZ increased OPN and reduced ALP; RoekoSeal has caused decreasing OPN... (Complete abstract click electronic access below)
174

Avaliação das propriedades físicas, químicas e biológicas do cimento Portland associado á radiopacificadores micro e nanoparticulados

Silva, Guilherme Ferreira da [UNESP] 27 March 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-27Bitstream added on 2014-06-13T20:22:23Z : No. of bitstreams: 1 silva_gf_dr_arafo.pdf: 734528 bytes, checksum: 5b7088d188f8d1f4141373625e85f325 (MD5) / Objetivo: Avaliar as propriedades físicas, químicas e biológicas do cimento Portland (CP) associado a diferentes radiopacificadores (óxido de zircônio - OZr e óxido de nióbio - ONb) micro e nanoparticulados. Metodologia: Para isso, os grupos experimentais foram divididos em: Capítulo 1 - CP, CP+20% de óxido de bismuto (OB), CP+30% OZrmicro e CP+30% OZrnano; Capítulo 2 - CP+30% ONbmicro, CP+30% ONbnano e MTA-Angelus. Todos os materiais foram submetidos aos testes de radiopacidade, tempo de presa, pH e liberação de íons cálcio. Além disso, nos materiais do capítulo 1 foi realizado o teste de resistência à compressão após 24 horas e 21 dias. A reação tecidual provocada pelos materiais foi investigada por meio de análises morfológica, morfométrica (densidade numérica de células inflamatórias, CI) e imuno-histoquímica (número de células imunopositivas à interleucina-6, IL-6) da cápsula formada após 7, 15, 30 e 60 dias de implantação no subcutâneo dorsal. O método von Kossa, para detecção de estruturas calcificadas, também foi realizado. Resultados: Capítulo 1 – Os materiais testados apresentaram pH alcalino e liberação de íons cálcio após 1, 7, 14 e 28 dias. Os materiais CP+OB, CP+OZrmicro e CP+OZrnano apresentaram valores de radiopacidade estatisticamente superiores ao CP e similares entre si. O CP+OZr micro e o CP+OZr nano exibiram tempos de presa maiores do que CP (p≤0,05). O CP apresentou valor de resistência à compressão, após 24 horas e 21 dias, maior do que os materiais, porém, a adição de OZr promoveu médias estatisticamente superiores quando comparado ao CP+OB. Em todos os grupos, verificou-se redução significante no número de CI e de células imunopositivas à IL-6 aos 15, 30 e 60 dias em comparação à 7 dias. O número de CI e de células imunomarcadas à IL-6 nos materiais... / Objective: The aim of this study was to evaluate the effect of different micro e nanoparticulated radiopacifiers (zirconium oxide – ZrO and niobium oxide - NbO) on the physicochemical and biological properties of Portland cement (PC). Methods: The experimental groups were divided in: Chapter 1 - PC, PC+20% bismuth oxide (BO), PC+30% ZrOmicro e PC+30% ZrOnano; Chapter 2 - PC+30% NbOmicro, PC+30% NbOnano and MTA-Angelus. All materials were submitted to the tests of radiopacity, setting time, pH and calcium ion release. Besides, in the materials of chapter 1, the test of compressive strength after 24 hours and 21 days was performed. Moreover, tissue reaction promoted by all materials was evaluated in rat subcutaneous. In each rat, two polyethylene tubes filled with materials were implanted into dorsal subcutaneous. Empty tubes were used as control. After 7, 15, 30 and 60 days, the specimens were fixed and embedded in paraffin. In the HE-stained sections, the number of inflammatory cells (IC) in the capsule was obtained. Moreover, detection of interleukin-6 (IL-6) by immunohistochemistry and number of IL-6 immunolabeled cells were carried out. The von Kossa method was also performed. The differences among the groups were subjected to ANOVA with a significance level of 5%. Results: Chapter 1 – All materials presented an alkaline pH and released calcium ions after 1, 7, 14 and 28 days. The PC+BO, PC+ZrOmicro and PC+ZrOnano exhibited radiopacity values statistically superior than PC. The PC+ZrOmicro and PC+ZrOnano presented setting times higher than PC (p≤0.05). After 24 hours and 21 days, the PC showed compressive strength value significantly superior to the other materials. A higher compressive strength in the PC+ZrO (micro and nano) was found compared to PC+BO. In all groups, significant reduction in... (Complete abstract click electronic access below)
175

Efeito da ciclagem mecânica em pré-molares restaurados com inlays confeccionados com diferentes materiais cerâmicos na resistência de união dentina-restauração

Trindade, Flávia Zardo [UNESP] 27 September 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-09-27Bitstream added on 2014-06-13T19:24:15Z : No. of bitstreams: 1 trindade_fz_dr_sjc.pdf: 1437999 bytes, checksum: e9fcd07315e6ddb6e97668184b6537e4 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Tendo em vista os diversos materiais presentes no mercado, e que a interface adesiva é a principal responsável pela durabilidade de restaurações estéticas, é importante avaliarmos que material apresenta melhor desempenho na cavidade bucal, promovendo sucesso no emprego de restaurações estéticas. Dessa forma, esse estudo teve como objetivo avaliar a resistência de união entre cinco diferentes tipos de restaurações cerâmicas, em cavidades do tipo inlay, e o substrato dentário (pré-molares superiores) antes e após ciclagem mecânica. Para isso, 100 pré-molares superiores íntegros receberam preparos MOD e restaurações inlays foram confeccionadas. Os espécimes foram, então, divididos em 10 grupos (n=10), de acordo com 2 fatores de estudo (fatorial 5 x 2): fator estratégia restauradora (5 diferentes tipos de restauração cerâmica com diferentes composição, microestrutura e forma de processamento: e.Max Press, e.Max CAD, Vita PM9, Vita Mark II e Vita VM7); fator ciclagem mecânica (com ciclagem [100 N, 2 Hz, 1,2 x106 ciclos] e sem ciclagem). Em seguida, todos os espécimes foram seccionados no sentido x e y, para se obter espécimes em forma de barras (non-trimming approach) compostos de dentina vestibular – restauração – dentina lingual, para então serem submetidos a teste de microtração. A superfície de fratura foi analisada com auxílio de um estereomicroscópio e o modo de falha determinado. Além disso, uma análise de elementos finitos para avaliação da distribuição de tensões nas restaurações foi empregada. 11 Os dados obtidos foram analisados estatisticamente de acordo com sua distribuição. A ciclagem teve significante efeito (p= 0,0087 < 0,05) no grupo da cerâmica e.Max Press (G1 e G2), enquanto a resistência de união não foi afetada pela ciclagem nas demais... / Nowadays, a great variety of ceramics are available in the market. The knowledge about the technique that provides better durability to restoration is important. Moreover, because of the adhesive interface is the main responsible for the durability of aesthetic restorations, it is important to evaluate which material presents the best long-term clinical performance to ceramic inlays and provides success in the aesthetic restorations. The purpose of the present study is to evaluate the bond strength of five different ceramics inlays to the tooth structure (upper pre-molar) after mechanical cycling. Then, 100 upper pre-molar received inlays ceramics with different compositions and manufacturing processes and were divided into 10 groups (n=10), in accordance to 2 factors of study: types of ceramic (5 different types of ceramic restorations with compositions, microstructures and manufacturing processes: e.Max Press, e.Max CAD, Vita PM9, Vita Mark II and Vita VM7); and mechanical cycling factor (with mechanical cycling [100N, 2Hz, 1,2 x 106 cycles] and without mechanical cycling). After that, all the specimens was cuted in x and y axis, (non-trimming approach). These bars were composed by dentine - restoration - lingual dentine. The bond strength of the bars was measured by microtensile bond strength test. The fractured ceramic surfaces were examined under a stereomicroscope and the failure mode... (Complete abstract click electronic access below)
176

Resistência de união de cimentos resinosos em superfície de cerâmica de Y-TZP após aplicação de filme vitrocerâmico

Antunes, Débora Pinto [UNESP] 08 April 2014 (has links) (PDF)
Made available in DSpace on 2015-05-14T16:53:13Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-04-08Bitstream added on 2015-05-14T16:59:11Z : No. of bitstreams: 1 000822661.pdf: 3005956 bytes, checksum: aa617124450c9641b6ecb66c3cbbdaa9 (MD5) / Comparou-se a resistência de união (RU) dos cimentos resinosos Panavia F (P) (Kuraray) e RelyX U200 (R) (3M ESPE) à cerâmica zircônia através de três diferentes métodos de tratamento da superfície: 1- silicatização triboquímica (ST) (Rocatec Soft - 3M ESPE); 2- glaze (G) (Akyzent glaze spray- VITA); 3- aplicação de vidro bioativo (VBA). Blocos pré-sinterizados do sistema Zirkonzahn (Zirkonzahn) foram seccionados de modo a produzir 90 blocos menores (5 x 4 x 3 mm). Os blocos foram polidos em Politriz com lixas d’água de granulação fina 1000 e 1200 (3M ESPE) e limpos em banho ultrassônico contendo álcool isopropílico a 96% durante 5 min. Após a sinterização dos blocos cerâmicos, foi realizada a aplicação do tratamento de superfície. O Rocatec Soft foi jateado com 2,8 bar, ângulo de incidência perpendicular e distância padrão de 10 mm por 25 s em movimentos circulares. O Akyzent Glaze Spray foi pulverizado por 2 s e em seguida sinterizado em forno Vacumat (Vita) de acordo com recomendações do fabricante. Após a aplicação de 1 gota do vidro bioativo, procedeu-se a secagem e sinterização a 1200 ºC deste material. Em todos os grupos aplicou-se agente de união silano Monobond-S (Ivoclar Vivadent). Nos grupos 3, 4, 5 e 6 a superfície foi primeiramente condicionada com ácido hidrofluorídrico (HF) a 5% durante 2 min, lavada e depois silanizada. A cimentação foi realizada com um dispositivo (Ultradent), produzindo cilindros de cimento resinoso com 2 x 1mm.! Após 24 h os espécimes foram envelhecidos em termocicladora com 5.000 ciclos com banhos de temperatura entre 5 e 55 ºC e submetidos ao ensaio de cisalhamento na Shear Bond Tester (Bisco). O VBA foi analisado qualitativamente por meio de análise térmica diferencial (DTA), através de difração de raios-x (DRX)(Panalytical) e espectroscopia de energia dispersiva de raio-x (EDS) (Oxford Instruments)... / The bond strength of resin cements Panavia F (P) (Kuraray) and RelyX U200 (R) (3M ESPE) to zirconia using three different surface treatments: 1 - triboquemical silicatization (ST); 2 - glaze (G) 3 - bioactive glass (VBA) was compared. Blocks of Zirkonzahn system were cut producing 90 smaller blocks (5 x 4 x 3 mm). The blocks were polished with water finegrained 1000 and 1200 sandpaper in Politriz and cleaned with 96% isopropyl alcohol for 5 min. The Rocatec Soft was etched with 2.8 bar, in a perpendicular way and a distance of 10 mm for 25 s in a circular motion. The Akyzent Glaze Spray was sprayed by 2s and then sintered in oven Vacumat (Vita) according to manufacturer's recommendations. After application of 1 drop of bioactive glass, the material was dried and sintered at 1200 °C. In all groups was applied silane coupling agent Monobond- S (Ivoclar Vivadent). In groups 3, 4, 5 and 6 the surface was first etched with 5% hydrofluoric acid (HF) and then silanized. The cementing was carried out with a device (Ultradent), producing cured cement cylinders of 2 x 1mm. After 24 h the specimens were aged in thermocycler with 5,000 cycles at a temperature of 5 and 55 ºC and subjected to microshear test on Shear Bond Tester (Bisco). VBA was analyzed by means of DTA, XRD and EDS. Optical profilometry (PO) was performed to obtain roughness. After fracture the samples were analyzed through SEM. It was found that XRD revealed the formation of a glass ceramic film. DTA shows that the temperature of 1200 °C is the most suitable for sintering. DRX showed the formation of a glass ceramic film. According to ANOVA, the interaction effect was significant (p = 0.003 < 0.05). The test for multiple comparison of means, Tukey (5%) showed that the TBS (MPa) for VBA were significantly higher than the other groups (with 26.94 ± 3.50 to P and 28.36 ± 3.32 to R), regardless cement kind used. The lowest result...
177

Influência de três tratamentos de superfície para cerâmicas a base de zircônia na resistência adesiva e no comportamento à fadiga do material

Amaral, Marina [UNESP] 06 June 2014 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:34:52Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-06-06. Added 1 bitstream(s) on 2015-06-18T12:46:53Z : No. of bitstreams: 1 000826190.pdf: 2371983 bytes, checksum: 1a6cae4c3630473d345c8d57f0a5e4ee (MD5) / O objetivo deste trabalho é avaliar o efeito de dois diferentes métodos de deposição de sílica na superfície de uma cerâmica a base de zircônia estabilizada por ítria na adesão a um cimento resinoso e no limite de fadiga do material. A hipótese testada é que ambos os tratamentos de superfície promoverão aumento da adesão entre zircônia e cimento resinoso, e de que a adição de uma camada de sílica reduzirá a resistência à flexão biaxial de discos Y-TZP, antes e após ciclagem mecânica; já o jateamento aumentará a resistência da cerâmica nas duas condições, seguindo o mesmo padrão para o limite de fadiga. Para o teste de adesão, 45 barras receberam um dos seguintes tratamentos de superfície (n = 15): controle: grupo controle, sem tratamento adicional após sinterização; silicatização: jateamento com partículas de SiO2 30 μm (Rocatec Soft, 3M ESPE); glaze: aplicação de uma única camada de vidro amorfo (Glaze Vita Akzent - Vita Zanhfabrik) e condicionamento com HF por 1 min. As amostras foram cimentadas (cimentação resinosa) à secções de cerâmica de dissilicato de lítio e, após 2500 ciclos térmicos, o teste de resistência adesiva à tração foi executado. Para avaliação das propriedades mecânicas, corpos de prova em forma de disco da cerâmica VITA In-Ceram 2000 YZ cubes for InLab foram confeccionados de acordo com as normas do ensaio de flexão biaxial. Os tratamentos de superfície avaliados são: controle; silicatização; e Glaze/HF. Os corpos de prova foram submetidos a flexão biaxial antes e após ciclagem mecânica (2 x 106 ciclos, 100 N, biaxial, imersão em água 37 ºC, 4 Hz). O método de escada foi utilizado para determinação do limite de fadiga dos corpos de prova, com 102, 103, 104 e 105 ciclos. A resistência adesiva foi maior para o grupo silicatização, seguido pelo grupo Glaze/HF e por ultimo o grupo controle, o qual não resistiu à ciclagem térmica. A ciclagem mecânica.. / The aim of this study is to evaluate the effect of different silica deposition methods on the surface of a zirconia ceramic on the adhesion to a resin cement and on the fatigue limit of the materials. The tested hypothesis is that surface treatments enhance the adhesion of resin cement to zirconia, and that the application of a silica layer reduces the flexural strength of zirconia discs, before and after mechanical cycling, and that air abrasion enhance the strength in both situations, following this patter also to fatigue limits. For the adhesive test, 45 bars received the following surface treatments (n = 15): control: without surface treatment after sintering; air-abrasion: 30 μm SiO2 particles (Rocated Soft, 3M ESPE); glaze: application of a thin layer of glaze (Glaze Vita Akzent - Vita Zanhfabrik), HF etching during 1 min plus silane. Samples were resin cemented to lithium dissilicate slices, and after 2,500 cycles of thermocycling, the tensile test was performed. Disc-shaped specimens were used for the evaluation of mechanical properties. The same surface treatments were performed on the tensile side of the samples. Specimens were submitted to biaxial flexural strength before and after mechanical cycling (2 x 106 cycles, 100 N, water immersion 37 ºC, 4 Hz). Stair case method was used to determine the fatigue limit of samples at 102, 103, 104 and 105 cycles. Adhesive strength was higher for air abraded group, compared to glaze group; control group did not survived thermocycling. Mechanical cycling had no effect on flexural strength. Air abrasion presented the highest values of flexural strength. Weibull analysis showed the highest m value for air abraded group without mechanical cycling, and the highest value was presented by glazed and mechanical cycled group. In stair case analysis, all groups presented a decrease in fatigue limit according to increase in number of cycles; air ...
178

Abordagens estatísticas em testes de resistência de união entre dentina bovina, sistema adesivo e resina composta

Balducci, Ivan [UNESP] 25 April 2014 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:24:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-04-25. Added 1 bitstream(s) on 2015-09-17T15:47:55Z : No. of bitstreams: 1 000844174.pdf: 1728436 bytes, checksum: 6c4b793420a35ded6629f8099de66606 (MD5) / O objetivo deste estudo foi empregar diferentes abordagens estatísticas em dados obtidos em ensaios de micro e macrotração, em dois períodos de tempo de armazenamento, a fim de descrever e quantificar a variabilidade comumente encontrada nos testes de adesão. Foram selecionados 48 dentes bovinos. As raízes seccionadas a 2 mm abaixo da junção cementoesmalte e as faces vestibulares foram desgastadas expondo superfície de dentina plana. Os dentes foram embutidos em resina acrílica e aleatoriamente designados a quatro grupos (n = 12) para avaliação da resistência de união (RU). Para o teste de microtração foi aplicado o adesivo Adper Single Bond 2- (SE Bond 2- 3M-ESPE) numa área de 8 mm2, seguido de jato de ar por 2 a 5 s e fotopolimerização por 15 s e, a seguir, inserida a resina composta Z350 XT- (3 M-ESPE). Após 24 h de armazenamento, em água destilada a 37 ºC, para cada dente um número variável de palitos foi obtido. Doze dentes foram submetidos ao teste de microtração após 24 h (G1) e outros 12 submetidos à termociclagem (G2) seguido de microtração. Para a macrotração, a base menor dos espécimes cônicos foi de 2 mm. Doze amostras após 24 h foram submetidas ao teste de macrotração (G3) e as outras doze, após as 24 h, termocicladas (G4). Os dados foram submetidos a uma análise exploratória; seguidos de uma análise confirmatória (inferencial). A estatística descritiva e o resultado da análise de Weibull para os dados de RU (MPa) foram: G1(módulo; média ± desvio padrão: 2,54; 10,76 ± 4,21); G2 (3,36; 19,34 ± 6,42); G3 (1,96; 3,17 ± 1,51; G4 (1,75; 2,86 ± 1,68). O teste ANOVA (2-way), α = 5%, indica efeito interação significante e, os testes de Tukey e de Dunn (5%), complementaram os resultados. Pôde-se concluir: as diferentes estratégias estatísticas (análise de Weibull, análise exploratória e abordagem paramétrica) indicaram os mesmo resultados. Pode-se concluir: as diferentes... / The aim of this study was to use different statistical approaches on data obtained from micro and macrotensile tests in two periods of time storage, in order to describe and quantify the variability commonly found in adhesion tests. 48 bovine teeth were selected. The roots were sectioned 2 mm below the cement-enamel junction and the buccal surfaces were ground to exposure a dentin flat surface. The teeth were embedded in acrylic resin and randomly assigned to four groups (n = 12) to evaluate the bond strength (BS). For the microtensile test the adhesive Adper Single Bond 2 - (2 SE Bond - 3M - ESPE) was applied in an area of 8 mm2, followed by air jet during 2 to 5 s and curing for 15 s. Right after the XT - Z350 composite resin (3M ESPE) was inserted. After 24 h of storage in distilled water at 37 °C, for each tooth a variable number of sticks was obtained. Twelve teeth were submitted to microtensile test after 24 h (G1) and other 12 to thermocycling (G2) and microtensile test. For macrotensile, the smallest base of conical shape specimens was 2 mm. After 24 h twelve samples were subjected to macrontesile test (G3) and the other twelve, after 24 h, were thermocycled (G4). The data were submitted to an exploratory analysis, followed by a (inferential) confirmatory analysis. Descriptive statistics and the results of Weibull analysis for the data of BS (MPa) of the experimental conditions were: G1 (module; mean ± standard deviation: 2.54; 10.76 ± 4.21); G2 (3.36; 19.34 ± 6.42); G3 1.96; 3.17 ± 1.51; G4 (1.75; 2.86 ± 1.68). The ANOVA (2-way), α = 5%, indicated significant interaction effect, and Tukey tests and Dunn (5%), complemented the results. The conclusion is: the different statistics strategies (Weibull analysis, exploratory analysis and parametric approach) showed the same results, namely the existence of the aging effect only for the microtensile bond; in the comparison betw...
179

Estudo comparativo da textura superficial entre os materiais estéticos indiretos

Dias, Alexandre Henrique de Moura [UNESP] 30 June 2000 (has links) (PDF)
Made available in DSpace on 2014-11-10T11:10:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2000-06-30Bitstream added on 2014-11-10T11:57:20Z : No. of bitstreams: 1 000124943.pdf: 2856695 bytes, checksum: d61150204b12b1d758131e6fb0dbf8e1 (MD5) / O propósito deste estudo foi avaliar a rugosidade superficial entre materiais de revestimento estético indiretos (Vita VMK95, Solidex, Artglass, Targis). Para tanto, confeccionaram-se 10 corpos-de-prova nas dimensões de 6mm de comprimento por 6mm de diâmetro de cada material. Uma das superfícies planas recebeu acabamento e polimento, conforme recomendações do fabricante. As amostras concluídas foram submetidas a mensuração, através do rugosímetro Hommel Tester T500. Os valores médios de rugosidade máxima entre os materiais em questão, foram 5,731Jm, 5,151Jm, 6,83 1.1m e 3, 721Jm, respectivamente. A seguir foram submetidos a análise de variância (ANOVA), ao nível de 5%, sendo detectado significância. Concluiu-se que o material Sofidex não apresentou diferença estatisticamente significante entre os grupos, enquanto o Targis apresenta significância estatística em relação ao Artglass e a cerâmica Vita vmk95. / The purpose of this study was to evaluate surface rugosity among indirect esthetic materials (Vita VMK 95, Solidex, Artglass, Targis). Ten samples of each material in the cilindric shape with dimension 6 x 6 mm were manufactured. The surface were submitted to finishing and polishing, according to manufacturer's recommendations. The samples were submitted to measuremenst, using the Hommel Tester T500 device. The average values of maxim surface rugosity among the materiais ín question, were 5, 73pm; 5, 15pm; 6, 83 j.Jm e 3, 72 j.Jm, respectively. Sample were also subjectted to variance analysis- ANOVA (5%), had detected significance. Concluded that the material Solidex did not present significant statistical differences among groups, while Targis presented significant statistical differences in relation to the Artglass and the ceramic Vita vmk95.
180

Verificação da dureza de gessos em função da compatibilidade com materiais de moldagem à base de borracha

Araujo, Rosehelene Marotta [UNESP] January 1986 (has links) (PDF)
Made available in DSpace on 2014-11-10T11:10:01Z (GMT). No. of bitstreams: 0 Previous issue date: 1986Bitstream added on 2014-11-10T11:57:18Z : No. of bitstreams: 1 000023121.pdf: 1889129 bytes, checksum: 7d413d7d31d94f2b417c51acb5fba4e0 (MD5) / O material mais empregado atualmente na construção de modelos é o gesso, que a par de técnica simples reúne condições bastante satisfatórias com relação às propriedades mecânicas, físicas e químicas. Porém, a compatibilidade relativa dos gessos com os materiais de moldagem pode comprometer as qualidades da superfície do modelo. Em nosso trabalho, estudamos a Dureza de dois tipos de gessos: tipo III (gesso pedra) e tipo IV (gesso pedra melhorado), bem como a influência do contacto com três tipos de materiais de moldagem: silicone polimerizada por condensação (Xantopren), polissulfeto (Permlastic) e silicone polimerizada por adição (Provil). Como parâmetro de comparação foi utilizado o gesso reagindo em contacto com uma superfície de vidro...... ( (Resumo completo , clicar acesso eletrônico abaixo) / Currently the most widespread material used in dies is gypsum that together with its simple technique has very satisfactory mechanical, chemical and physical properties. However, its compactibility with the impression materials can compromise the die surface quality. In our work, we studies the hardness of the two gypsum types: Type III (die stone) and type IV (improved die stone), as well as the influence of the contact with three types of impression materials: polymerized silicone for condensation (Xantopren), polysulfide (Permlastic) and polymerized silicone by addition (Provil). As comparison parameter gypsum was used in contact with a glass surface…(Complete abstract click electronic access below)

Page generated in 0.1069 seconds