• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 907
  • 81
  • 78
  • 78
  • 78
  • 68
  • 7
  • 7
  • 6
  • 6
  • 4
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 922
  • 922
  • 454
  • 392
  • 234
  • 208
  • 160
  • 149
  • 100
  • 97
  • 81
  • 69
  • 69
  • 69
  • 66
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Variações termicas ocorridas na camara pulpar em função de tecnicas de inserção e tipos de fotoativação de composito

Guiraldo, Ricardo Danil 18 February 2005 (has links)
Orientador: Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:44:51Z (GMT). No. of bitstreams: 1 Guiraldo_RicardoDanil_M.pdf: 364199 bytes, checksum: 276b6a4ebf54255a1b8a3ee68f8b30de (MD5) Previous issue date: 2005 / Resumo: O estudo avaliou o efeito dos tipos de incremento, de fotoativação e as fases restauradoras nas variações térmicas ocorridas na câmara pulpar, durante a fotoativação do compósito Filtek Z250. Foram utilizados 90 incisivos bovinos, nos quais foram feitos preparos cavitários (3x3x2,5mm) padronizados. Os dentes foram separados aleatoriamente em 3 grupos, de acordo com o tipo de fotoativação por luz halógena: 1- contínua (700 mW/cm2 por 20 s); 2- dupla intensidade (inicial de 100 mW/cm2 por 5 s, seguido de 700mW/cm2 por 15 s); 3- intermitente (2 s de ativação com 700mW/cm2, seguido do mesmo tempo pela ausência de luz, total de 40 s). Os grupos foram separados em 3 subgrupos segundo o tipo de incremento: 1- único; 2) oblíquos (três incrementos, um colocado nas paredes cervical e axial, outro nas paredes incisal e axial e o último unindo os dois); 3) horizontal/verticais (o horizontal foi colocado na parede axial, um vertical na parede cervical e o outro na parede incisal), totalizando 9 grupos (n=10). As cavidades foram condicionadas com ácido fosfórico por 20 s, o sistema de união Single Bond e o compósito Filtek Z250 aplicados segundo os protocolos de fotoativação e incremento. As restaurações foram realizadas em ambiente controlado (37ºC e 50±10% UR) e as temperaturas registradas com termômetro digital acoplado ao termopar tipo-K introduzido no canal radicular, de maneira que ficasse em contato com a dentina da câmara pulpar, correspondente à parede axial do preparo. Os dados obtidos foram submetidos à análise de variância e as médias ao teste de Tukey em níveis de 5% e 1%. A média de temperatura do incremento único (37,14ºC) foi significantemente menor que dos incrementos oblíquos (37,44ºC) e horizontal/verticais (37,43ºC). A luz contínua promoveu valor de temperatura (37,53ºC) estatisticamente superior aos demais tipos de luz, os quais não deferiram (37,27ºC e 37,21ºC). A fotoativação do adesivo foi estatisticamente maior (37,54ºC) que na aplicação do adesivo (36,82ºC) e na ativação do compósito (37,20ºC). Na interação tipo de incremento-tipo de fotoativação, na luz contínua o maior calor foi promovido pelo incremento horizontal/verticais, estatisticamente diferente dos demais. Na dupla intensidade, a maior temperatura foi no incremento oblíquo, diferente dos demais, enquanto na pulsátil não houve diferença. Para o incremento único não houve diferença quanto à fotoativação, enquanto no oblíquo a luz pulsátil promoveu valor significantemente menor. No incremento horizontal/verticais, a luz contínua foi estatisticamente superior. Na interação tipo de incremento-fase restauradora, o calor do incremento único foi estatisticamente superior na fotoativação do adesivo, seguido pela fotoativação do compósito e aplicação do adesivo. Para os incrementos oblíquo e horizontal/verticais, a fase aplicação do adesivo foi significantemente menor. Para as fases restauradoras não houve diferença estatística entre aplicação e fotoativação do adesivo, entretanto na fotoativação do compósito, o incremento único foi significantemente menor. Na interação tipo de fotoativação-fase restauradora, em todas as fotoativações não houve diferença estatística no calor das fotoativações dos adesivo e compósito, diferindo estatisticamente da fase aplicação do adesivo. Para as fotoativações do adesivo e do compósito, o calor produzido pela luz contínua foi significantemente maior, enquanto na aplicação do adesivo não houve diferença estatística. Houve influência das variáveis sobre o calor que atingiu a câmara pulpar / Abstract: This study evaluated the effect of the increment insertion and light-curing methods on thermal variations in the pulp chamber during Filtek Z250 composite resin light-curing. Standard cavities (3x3x2.5mm) were prepared in 90 bovine incisors. The teeth were randomly assigned into 3 groups, according to each light-curing method: 1- continue halogen light (700 mW/cm2 per 20s); 2- halogen light with a soft-start mode (initial intensity of 100 mW/cm2 per 5s obtained with a spacer and 700mW/cm2 per 15s, totalizing 20s); 3- intermittent halogen light (2s of activation with 700mW/cm2, followed by the same time of light absence, totalizing 40s). All groups were divided into 3 subgroups according to each type of increment: 1- bulk; 2- oblique (three increments, one in the cervical and axial walls, one in the incisal and axial walls, and finally one joining the the other two); 3- horizontal/vertical (the horizontal in the axial wall, one vertical in the cervical wall and another vertical in the incisal wall), totalizing 9 groups (n=10). All cavities were etched with phosphoric acid for 20s; the adhesive system Single Bond and the resin composite Filtek Z250 were applied according to the types of light-curing and increment. All experiments were carried out in controlled environment (37 Celsius degree and 50±10% relative humidity). The temperature variations (Celsius degree) were obtained using a digital thermometer attached to a type-K thermocouple which was inserted into the root canal as to be in contact with the pulp chamber dentine, correspondent to the axial wall of the cavity. Data were submitted to ANOVA and mean values compared by the Tukey¿s test with significance levels of 5% and 1%. The mean temperature (37.14) of the bulk increment was significantly lower than that oblique (37.44) and horizontal/verticals (37.43) increments. The continue light-curing revealed temperature mean values (37.53) statistically higher than those observed for the other types of light (37.27 and 37.21), which did not differ from each other. The adhesive light-curing showed statistically higher temperatures (37.54) than those observed during the adhesive application (36.82) and resin composite light-curing (37.20). In relation to the interaction between the light-curing method and type of increment, the horizontal/vertical increment under continue halogen light showed the highest temperature values, statistically different from the others. As for the soft-start light-curing method, the highest temperature was observed for the oblique increment, statistically different from others; no difference was observed for the intermittent halogen light. For the bulk increment, no statistically significant differences were observed among groups concerning the light-curing methods; however, in the oblique increment, the intermittent light revealed lower temperature values. For the horizontal/vertical increment, the continue light-curing temperature was statistically higher. For the interaction between type of increment and the restorative phase, the bulk increment heat was statistically higher in the adhesive light-curing phase, followed by the resin composite light-curing and adhesive application. The horizontal/vertical and oblique increments revealed significantly lower temperature values during adhesive application. In the restorative phases, no difference was observed between adhesive application and adhesive light-curing. However, in the resin composite light-curing, the bulk increment showed significantly lower temperature values. For the interaction between type of light-curing and restorative phase, no statistical difference was observed for all light-curing methods concerning adhesive and resin composite light-curing, differing only in the adhesive application phase. For the adhesive and resin composite light-curing phases, the heat produced by continue light was significantly higher. No statistically significant difference was verified for adhesive application. There was influence of the variables on the heat that reached the pulpar chamber / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
62

Efeito do sistema restaurador (compósito e sistema adesivo) e termociclagem na interface dente/restauração classe V : avaliação em OCT e MEV / Restorative system (composite and adhesive system) and thermal cycling influencing teeth/class V restoration interface : OCT and MEV evaluated

Sampaio, Camila Sobral, 1989- 22 August 2018 (has links)
Orientador: Regina Maria Puppin Rontani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T09:19:07Z (GMT). No. of bitstreams: 1 Sampaio_CamilaSobral_M.pdf: 4499191 bytes, checksum: e827ca1cd97b2ad41e3b5fdf21d70308 (MD5) Previous issue date: 2013 / Resumo: O objetivo deste estudo foi avaliar a interface dente/restauração classe V realizada com diferentes sistemas adesivos (condicionamento total e auto-condicionante) e compósitos restauradores (baixa contração e convencional), submetidas à termociclagem (TC), por meio de Tomografia por Coerência Óptica (OCT) e infiltração por nitrato de prata em Microscopia Eletrônica de Varredura (MEV). Foram utilizados 90 terceiros molares humanos livres de cárie, onde foram realizados preparos tipo Classe V (0,7 mm/profundidade x 2 mm/diâmetro), com margens localizadas em esmalte e dentina. Os dentes foram distribuídos aleatoriamente em 6 grupos de 15 dentes cada, de acordo com o sistema adesivo e compósito restaurador utilizado: Grupo 1 - Adper Single Bond 2 (SB2) + Aelite LS Posterior (AP); Grupo 2 - SB2 + Venus Diamond (VD); Grupo 3 - SB2 + Filtek Z250 XT (Z250); Grupo 4 - Clearfil SE Bond (CSE) + AP; Grupo 5 - CSE + VD; Grupo 6 - CSE + Z250. Todos os grupos foram avaliados pré e pós TC por OCT (n=10). Após a TC (1000 ciclos entre 5 e 55°C), 5 dentes de cada grupo foram selecionados aleatoriamente para a realização da infiltração por nitrato de prata. Para cada grupo, outros 5 dentes foram preparados e não submetidos à TC, também para esta avaliação. A infiltração por prata foi visualizada em MEV em aumentos de 50x e 1000x, e posteriormente classificados por escores: 0-sem infiltração; 1- infiltração em camada híbrida; 2- infiltração em camada híbrida e túbulos dentinários; e 3- infiltração em camada híbrida, túbulos dentinários e sistema adesivo. Para a análise das imagens geradas por OCT, foi utilizado o programa Image J. As interfaces esmalte e dentina foram analisadas separadamente. Os dados foram submetidos à análise estatística de metodologia de modelos mistos para medidas repetidas (PROC MIXED para medidas repetidas) e teste de Tukey Kramer (p?0,05%). Para interfaces em dentina, observou-se interação significativa entre sistema adesivo e TC; as restaurações com o sistema adesivo CSE, após TC, apresentaram menores porcentagens de fendas na interface dente/restauração, para todos os compósitos, em comparação com o sistema adesivo SB2. Os resultados após a realização da TC demonstraram maiores valores de fendas, quando comparadas às mesmas amostras previamente à sua realização. Em esmalte, não foram observadas fendas na interface dente/restauração, tanto previamente quanto posteriormente à TC, para os sistemas adesivos e compósitos. Foi realizada análise estatística descritiva para a infiltração por nitrato de prata. A análise de infiltração por prata, tanto previamente quanto posteriormente à TC, não mostrou infiltração em esmalte. Com relação à dentina, houve um aumento no percentual de fendas para todos os sistemas adesivos e compósitos restauradores posteriormente à realização de 1000 ciclos térmicos. Pode-se concluir que, dependendo do sistema adesivo utilizado, a TC pode produzir maiores índices de fendas na interface dente/restauração, para todos os compósitos / Abstract: The aim of this study was to evaluate the tooth / class V restoration interface accomplished by different adhesive systems (total and self-etching) and restorative composites (low shrinkage and conventional), submitted to thermal cycling (TC), using Optical Coherence Tomography (OCT) and silver nitrate leakage by Scanning Electronic Microscope (SEM). It was used 90 human caries free third molars, with class V preparations (0.7 mm/ 2 mm x depth/diameter), with margins located in enamel and dentin. The teeth were randomly divided in 6 groups of 15 teeth each, according to the adhesive and composite restorative system used: Group 1- Adper Single Bond 2 (SB2) + Aelite LS Posterior (AP); Group 2- SB2 + Venus Diamond (VD); Group 3- SB2 Filtek Z250 + XT (Z250); Group 4- Clearfil SE Bond (CSE) + AP; Group 5- CSE + VD; Group 6- CSE + Z250. All groups were subjected to pre and post thermal cycling by OCT evaluation (n=10). After TC (1,000 cycles between 5 and 55°C), 5 teeth of each group were randomly selected for the silver nitrate leakage evaluation. For each group, 5 other teeth were prepared and were not subjected to TC, also for this evaluation. The silver nitrate leakage was observed in SEM in 50x and 1,000x magnification and subsequently classified by scores: score 0- without infiltration; 1- infiltration in the hybrid layer; 2- infiltration in the hybrid layer and dentinal tubules; and 3- infiltration in the hybrid layer, dentinal tubules and adhesive. For the analysis of images generated by the OCT, it was used the Image J software. The enamel and dentin interfaces were analyzed separately. Data were submitted to statistical analysis of mixed model methodology for repeated measurements (PROC MIXED for repeated measurements) and the Tukey Kramer Test (p?0.05). For dentin interfaces, it was observed that there was a significant interaction between adhesive and TC; the restorations with CSE adhesive system, after TC, showed smaller percentages of gaps at the dentin / restoration interface, for all composites, comparing to the SB2 adhesive system. With respect to thermal cycling, the results after their achievement showed lower values of interfacial adaptation, when compared the same samples prior to their implementation. In enamel, it was not observed gaps in the interface, both pre and post-TC, for all composite and adhesive systems. Descriptive statistics was used to analyze silver nitrate leakage. For the analysis of silver nitrate leakage, it was observed that there was no infiltration by silver nitrate in enamel both before and after TC. With respect to dentin, there has been an increase in the marginal failure rates for all adhesive systems and restorative composites after 1000 thermal cycles. It can be concluded that, depending on the adhesive system, TC can provide higher percentage of gaps at the tooth/restoration interface, for both studied composites. CSE provided improved interfacial adaptation than SB2 / Mestrado / Materiais Dentarios / Mestra em Materiais Dentários
63

Avaliação da adaptação cervical de coroas totais ceramicas livres de metal antes e apos cimentação

Borges, Gilberto Antonio 07 February 2003 (has links)
Orientador : Lourenço Correr Sobrinho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T15:08:52Z (GMT). No. of bitstreams: 1 Borges_GilbertoAntonio_D.pdf: 6983339 bytes, checksum: 31e20358d57bb9c3f1b76abb4e370566 (MD5) Previous issue date: 2003 / Resumo: o objetivo deste estudo foi avaliar o desajuste cervical antes e após a fixação de coroas totais IPS Empress 2, Cergogold e In Ceram, em preparos sobre dentes bovinos, utilizando 2 tipos de cimento. Noventa incisivos bovinos foram embutidos em resina e as porções coronárias foram preparadas para receber coroas totais completas, usando pontas diamantadas nO 4103 com paredes axiais com expulsividade de 8° e término cervical em ombro reto. Trinta coroas com 8,0 mm de diâmetro por 8,5 mm de altura foram confeccionadas para cada tipo de cerâmica. Após, as coroas foram adaptadas sobre os preparos com carga de 9 kgf por 1 minuto e a discrepância marginal foi medida com microscópio de mensuração (STM). Em seguida, as coroas foram removidas e 15 amostras de cada tipo de cerâmica foram cimentadas sobre os dentes com cimento resinoso (Variolink 11) e 15 com ionômero de vidro modificado por resina (Vitremer) e novamente a discrepância marginal foi medida. Os resultados foram submetidos à Análise de Variância e ao teste de Tukey (5%) e indicaram que os três sistemas cerâmicos apresentaram desajuste cervical após a cimentação estatisticamente superiores ao desajuste cervical antes da cimentação, para os dois cimentos. O sistema IPS Empress 2 apresentou valores de desajuste cervical estatisticamente superior ao Cergogold antes e após a cimentação. Nenhuma diferença estatística foi observada entre o sistema IPS Empress 2 e In Ceram e In Ceram e Cegogold. Para os três sistemas cerâmicos, nenhuma diferença estatistica foi observada para o desajuste cervical quando cimentadas com cimento resinoso e ionomero de vidro / Abstract: The purpose of this study was to evaluate the cervical fit before and after cementation of IPS Empress 2, Cergogold and In Ceram ali crowns, on bovine teeth preparation utilizing two kinds of the cement. Ninety bovin incisors were embedded in resin and the coronal portions of the teeth were prepared to receive complete crowns using a 4103 diamond bur under refrigeration with 10° of tapering and right shoulder. Thirty crowns with 8.0mm in diameter and 8.5mm height were fabricated for each ceramic system. After, the crowns were seated on the teeth with 9 kgf load for 1 minute and the marginal discrepancy was measured using a mensuration microscopic (STM). Afterwards, the crowns were removed and fifteen samples of each ceramic system were luted on the teeth with resin cement (Variolink 11) and glass ionomer cement (Vitremer) and the marginal discrepancy was measured again. The results were submitted to analysis of variance and Tukey's test (5%) and indicated that the three ceramics systems showed cervical fits after cementation statistically superior than cervical fits before cementation, for the two cements. The IPS Empress 2 showed values of the cervical fits statistically superior than Cergogold before and after cementation. No statistically significant difference was found between IPS Empress 2 and In Ceram and In Ceram and Cergogold. For the three ceramics systems, no statistically significant difference was found for the cervical fit cemented with resin cement and glass ionomer cement / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
64

Estudo de ligas metalicas alternativas empregadas na odontologia : analise quimica qualitativa e quantitativa, dureza superficial, manchas e oxidação

Stolf, Wolney Luiz, 1937- 03 August 2018 (has links)
Tese (livre-docencia) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T15:41:11Z (GMT). No. of bitstreams: 1 Stolf_WolneyLuiz_LD.pdf: 1856844 bytes, checksum: 4a93a10d660d3a242d80e6c676811661 (MD5) Previous issue date: 1993 / Resumo: Este estudo teve o objetivo de verificar a composição química qualitativa e quantitativa, dureza superficial e resistência a manchas e oxidação de ligas alternativas com baixo teor de ouro (Weissgold), de prata-paládio (Zilberpal), de prata (Zanardo, Superalloy, Spliteraloy, Tanaloy) e de cobre-alumínio (Dura cast MS, Idealloy). Os ensaios da análise química qualitativa e quantitativa foram feitos por espectometria de emissão atômica com plasma induzido de argônio (ICP-AES) modelo 975 ATOMCOMP-JARREL ASH. A dureza superficial Vickers foi verificada num aparelho Durimet (ERNEST LEITZ WETZLAR) de acordo a técnica proposta por RYGE, FOLEY e FAIRHUST59. As manchas e oxidação foram observadas após armazenamen todas amostras por quatro semanas em saliva artificial. As fotos das amostras antes e apôs armazenagem em saliva artificial foram comparadas e a quantidade de manchas e oxidação foram quantifica das e transformadas em números apresentadas em tabelas e gráficos. O autor concluiu que as ligas apresentaram uma composição básica condicente com seu sistema, apresentando peguenas variações em suas percentagens, além da inclusão de um ou outro ele mento químico diferente em sua composição. A dureza superficial para cada tratamento (liga virgem, fundida, refundida com 50% de liga virgem e refundida sem acresci mo de liga virgem) não apresentou uma coerência de resultados entre ligas. As manchas e oxidação também não apresentaram coerência de resultados para cada tratamento entre ligas. Esses resultados de dureza superficial e de manchas e oxidação sugerem que essas ligas alternativas não apresentam homogenidade ou são facilmente influenciáveis pelo processo de fundição / Abstract: The proposal of this study was to verify the chemical composition in quality and quantity, superficial hardness and resistance of stain and oxidation of alternative alloys with low-gold (Weissgolg), ailver-paladium (Zilberpal), silver (Zanardo, Superalloy, Spiteraloy, Tanaloy) and cooper-alluminium (Duracast MS, Idealloy). The chemical anlyse test in quality and quantity were done by Spectrometric of atomic emission with plasma conducible of argon (ICP-AES) model 975 ATOMCOMP-JARREL ASH. Vickers superficial hardness was verifyed in an aparattus Durimet (ERNEST LEITZ WETZIAR) in agree with the tecnigue of RYGE, FOLEY and FAIRHUST59. The stain and oxidation was observed after specimens storage during four weeks in artificial saliva. The pictures of the especimens before and after the storage in artificial saliva were compeared and the amount of stain and oxidation was quantified and transformed in numbers presented in tables and grafics. The autor concluded that the alloys presented a basic composition suitable with its system, with vary in percentage, yonder the inclusion of one or another different chemical element in its composition. The superficial hardness of each treatment (virgin alloy, cast, recast with 50% of virgin alloy and recast without virgin alloy) didn"t present a coherence in the results among the alloys. The stain and oxidation didn"t either present coherence in the results of each treatment among the alloys. These results of superficial hardness and of stain and oxidation suggest that the alternative alloys didn't present homogeneity or they are easily influenced by the cast process / Tese (livre-docencia) - Univer / Materiais Dentarios / Livre-Docente em Odontologia
65

Influencia de fontes de calor de fundição na fusibilidade e dureza de uma liga de Ni-Cr nova refundida acrescida ou não de liga nova

Fernandes, Daniela Rodrigues 24 April 2003 (has links)
Orientador: Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T16:20:02Z (GMT). No. of bitstreams: 1 Fernandes_DanielaRodrigues_M.pdf: 3687267 bytes, checksum: 9821b159222a8f053512a16a7c73db7e (MD5) Previous issue date: 2003 / Resumo: O objetivo deste trabalho foi verificar a influência da fonte de calor na fusibilidade e dureza de uma liga comercial à base de Ni-Cr (VERA BOND 11) nova, refundida (100%) e nova acrescida de sobras (50%). Para análise da fusibilidade foram confeccionadas 10 amostras para cada condição de liga, com uma tela para peneira de poliéster, com 11 X 11 filamentos de 0,22 mm de espessura, perfazendo uma malha de 100 espaços quadrados fixada bilateralmente por toda a extensão em fios de cera de 2,5 mm, contendo um pino formador do canal de alimentação no vértice. Para análise da dureza foram confeccionadas pastilhas em cera azul regular, com 8,0 mm de diâmetro por 2,0 mm de espessura, unidas a um pino formador do canal de alimentação. Após a obtenção dos padrões, estes foram fixados à base formadora do cadinho, de forma que a distância da base à câmara de reserva fosse 0,5 cm. Uma solução redutora da tensão de superfície foi aplicada sobre o padrão e após a secagem, este foi incluído em revestimento fosfatado - Termocast (Polidental, São Paulo Brasil) manipulado a vácuo, seguindo as instruções do fabricante quanto a proporção e tempo de manipulação. Os anéis foram aquecidos em forno elétrico (EDG) até atingirem a temperatura de 900°C, quando foram preenchidos por aproximadamente 15 gramas de liga fundida pela fonte de calor maçarico oxigênio/acetileno ou indução. A injeção da liga foi realizada por uma máquina centrifuga. Após a obtenção e limpeza dos corpos-de-prova foi realizada a análise de fusibilidade, com o auxílio de um microscópio comparador com aumento de 16 X, considerando o número de espaços preenchidos no molde pela liga. Para análise da dureza superficial Rockwell 30T, os corpos-de-prova foram incluídos em resina acrílica quimicamente ativada, polidos e levados ao aparelho de dureza Testor HTI Super-Panambra, onde foram realizadas as medidas e obtidas as médias. Os resultados foram submetidos à análise de variância e as médias comparadas pelo teste de Tukey, em nível de significância de 5%. Quando foram comparadas as fontes de calor com os diferentes tipos de liga houve diferença estatística significativa entre as fontes de calor, na qual o aquecimento por indução demonstrou melhores resultados para fusibilidade. Não houve diferença estatística significativa nos valores médios de dureza quando foi utilizada a fonte de calor maçarico e aquecimento por indução para as ligas virgem e mista, porém o aquecimento por indução demonstrou melhores resultados que o maçarico, diferindo estatisticamente os valores de dureza, quando da utilização da liga refundida / Abstract: The aim of the present study was to verify the influence of the heat source on the castability and hardness of a Ni-Cr-based commercial alloy ¿ VERA BOND 11 - in three different conditions: new (first use), recast, and new mixed with scraps. In order to evaluate castability, 10 specimens were made for each alloy condition, using a polyester sieve with 11x11 filaments, 0.22mm thick, resulting in a screen with 100 square spaces. This screen was fixed to 0.25mm threads along the extension of two sides, and a post was fixed to its vertex. In order to perform hardness analysis, circular specimens made of regular blue wax measuring 8.0 mm in diameter and 2.0 mm thick were connected to the post, forming the sprue. The patterns were then fixed to the casting chamber, so that the distance from the base to the reservoir was 0.5 cm. A surface tension-reducing solution was abundantly applied to the patterns and after drying, the patterns were embedded into a phosphate-bonded investment - Termocast (Polidental, São Paulo, Brazil) manipulated under vacuum pressure, following manufacturer's instructions regarding proportions and manipulation times. Casting rings were placed in an electric oven (Bravac) until the temperature of 900°C was reached, and were then filled with approximately 15 grams of alloy, molten either by an oxigen/acethylen gas torch or by induction as heat sources. Following this procedure, castability analysis was performed. A comparison microscope of 16x magnifying power was used to count the number of spaces which were filled by the alloy. In order to evaluate hardness Rockwell 30T, specimens were embedded in chemically activated acrylic resin and then placed on a Testor HTI Super-Panambra hardness teste r. Hardness values for each specimen were obtained, and the average hardness was calculated. Results were submitted to analysis of variance and averages were compared by Tukey's test at 5% probability. There were statistically significant differences between the heat sources applied to the different types of alloy, with induction presenting the best castability results. There were no statistically significant differences in the average hardness values between torch or induction as the heating source for new and mixed alloys, although induction showed the best results, leading to statistically significant differences in hardness, when recast alloy was used. / Mestrado / Mestre em Materiais Dentários
66

Avaliação dos procedimentos de acabamento e polimento sobre a rugosidade superficial de resinas compostas

Ono, Rosana 23 June 1995 (has links)
Orientador: Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-20T10:59:33Z (GMT). No. of bitstreams: 1 Ono_Rosana_M.pdf: 4255967 bytes, checksum: beac92cd6b873a75eec9adb61e7fe7f1 (MD5) Previous issue date: 1995 / Resumo: o propósito do presente trabalho foi avaliar "in vitro" a rugosidade superficial dos compósitos Herculite XR V (Sybron/Kerr), Z 100 (3M Co.) e Tetric (Vivadent), submetidos a diferentes procedimentos de acabamento e polimento. Foram confeccionados 24 corpos de prova de cada material, com 8mm de diâmetro por 2mm de espessura; o preenchimento da matriz foi incremental, com exposição individual de 60 segundos, com. fotopolimerizador Visilux 2 (3M). Após o procedimento total de polimerização, os corpos de prova foram removidos da matriz e armazenados, em estUfa, a 37° C e umidade relativa de 100% por 24 horas. Após este período de tempo, cada grupo de amostras foi submetido aos procedimentos de acabamento e polimento com diferentes tipos de materiais abrasivos. Cada procedimento de acabamento e polimento foi realizado por aproximadamente 2 minutos, respectivamente com auxílio do aparelho de alta velocidade de rotação (Turbina- DABI ATLANTE), refrigerados com jatos de água/ar, com movimentos lineares em uma única direção, e contra-ângulo (Micromotor DABI ATLANTE) em baixa velocidade de rotação, à seco. As superficies das amostras foram avaliadas antes e após cada procedimento e a leitura considerada foi a média aritmética entre os picos e vales (Ra), percorrida pelo perfilômetro (Prazis-Rug 3-Argentina), num trecho de 4,8mm. De acordo com os resultados, os procedimentos de acabamento com brocas de 30 lâminas e polimentos com Abrasivos de silicone Viking (cinza e verde) + Gel, discos Sof-Lex (fino e extrafino) e Enhance + Prisma Gloss produziram índices de rugosidade sem diferença estatisticamente significativa sobre Herculite XRV, Z 100 e Tetric. Os procedimentos de acabamento com pontas diamantadas F e FF e polimentos com Abrasivos de silicone Viking (cinza e verde) + Gel apresentaram índices de rugosidade com diferença estatisticamente significativa quando comparados aos polimentos com discos Sof-Lex (fino e extrafino) ou Enhance + Prisma Gloss, sobre I Herculite XR VeZ 100. Observou-se também que os procedimentos de acabamento com pontas diamantadas e polimentos com Abrasivos de silicone Viking (cinza e verde) + Gel, discos Sof-Lex (fino e extrafino) e Enhance não apresentaram diferenças estatisticamente significativas sobre o compósito Tetric / Abstract: The purpose of this study was to evaluate the in vitro surface roughness of Herculite XR V, Z 100 and T etric composite samples, subjected to different finishing and polishing procedures. A set of twenty-four 8mm diameter, 2mm thick samples was prepared for each studied material, using the incremental technique for mold filling. A sixty-second exposure to visible light was necessary to set the samples. The activating unit used was Visilux 2 (3M). After setting, the samples were stored in an oven, at 37°C and 100% relative humidity for 24 hours. Afterwards, each group of samples was subjected to the finishing and polishing procedures with different types of materials and abrasives. E,ach finishing and polishing procedure lasted approximatel y 2 minutes. The finishing procedure was carried out with the aid of an air-water spray, high speed handpiece, moved straight on a one and on1y direction. An air-cooled, low-speed handpiece was used for the polishing procedures. The surfaces of the samples were evaluated before and after each procedure and the reading that was ~sed was the arithmetic mean value between the peaks and valleys scanned by the surface t According to t he results, the finishing procedures with 30 blade burs, and polishing with Viking (grey and green) silicone abrasives + gel, Sof Lex (fine and extra-fine) discs and Enhance + Prisma Gloss, have produced roughness indexes without significant statistical differenceS for Herculite XRV, Z 100 and Tetric. The finishing procedures with F and FF diamond points and polishing procedures with Viking (grey and green) silicone abrasives + gel showed roughness indexes with significant statistical differences when compared to the polishing procedures with Sof- Lex (fine and extra-fine) disks or Enhance + Prisma Gloss, for Herculite XRV and Z 100. It has also been observed that the finishing procedures with diamond points and polishing procedures with Viking (grey and green) silicone abrasives + gel, I Sof-Lex (fine and extra-fine) disks and Enhance + Prisma Gloss didn't show significant statistical differences for Tetric composite / Mestrado / Materiais Dentarios / Mestre em Ciências
67

Avaliação da liberação de fluor de materiais restauradores em função dos meios de imersão

Carvalho, Adriana Silva de 20 June 1995 (has links)
Orientador: Jaime Aparecido Cury / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-20T14:18:36Z (GMT). No. of bitstreams: 1 Carvalho_AdrianaSilvade_M.pdf: 3083458 bytes, checksum: 4369d5e8175e32b0af665b44c634a192 (MD5) Previous issue date: 1995 / Resumo: A maior parte dos estudos realizados a respeito da avaliação da liberação de flúor de materiais restauradores tem sido feita em água destilada ou saliva artificial, que não simulam a dinâmica do meio bucal, ocorrendo até inversão de resultados, quando comparados com os resultados in vivo. Por isso resolvemos avaliar à liberação de flúor de diferentes cimentos de ionômero de vidro e resinas compostas em função do tempo de imersão em diferentes soluções, considerando a dinâmica do processo de cárie (des-remineralização). Para isso utilizamos os seguintes materiais restauradores: Chelon-fil (ESPE), Vitremer (3M), Variglas's (Dentsply), Dyract (Dentsply) e Tetric (Vivadent). Confeccionamos 18 amostras cilíndricas (área=I,65 cm2) de cada material, essas amostras foram imersas individualmente em 2 ml de cada solução estudada (6 amostras para cada solução). As soluções utilizadas foram água desionizada, saliva artificial e ciclagens de pH, deixando as amostras 6h na solução desmineralizante (Ca e P 2,0 mM, pH 4,3) e depois por 18h na solução remineralizante (Ca 1,5 mM, P 0,9 mM, pH 7,0). Essas soluções foram trocadas diariamente e armazenadas durante 15 dias. A liberação de flúor foi determinada após adição de volume igual de tampão TISAB II às soluções. Para a análise da concentração de flúor foi utilizado um eletrodo específico para flúor Orion 96-09, acoplado a um analisador de íons Orion EA-940. A liberação de flúor (média e desvio padrão) em Jlg F/cm2 foi: em água desionizada- CHE=7,6170:!:0,7619 a, VIT=5,9095:!:0,7939 b, VAR=2,7154:!:0,2463 c, DYR=I,4973:!:0,1699 d, TET=0,1361:!:0,0162 e; em saliva artificial- VIT=3, I 330:!:0,3.60 I a, CHE=I,2605:!:0,0842 b, DYR=I,2001:!:0,0519 b, V AR=0,7997:!:0,0981 c, TET=0,0741:!:0,0038 d; e nas ciclagens de pH- VIT=12,2727:!:1,1577 a, CHE=8,3472:!:0,5132 b, DYR=7,8196:!:0,6534 c, VAR=6,1725:!:0,2447 d, TET=0,2777:!:0,0234 e. Médias seguidas por letras distintas diferem entre si ao nível de significância de 5%. Os dados sugerem que a comparação de liberação de flúor de materiais dentários pode mudar quando os meios de imersão são considerados / Abstract: Most of data reported on release of f1uoride from dental materiaIs cements are based upon measurements made in de-ionized water and artificial saliva, which do not simulate the dinamic of caries development. So, the purpose of this study was to determine the levels of '" f1uoride release from differents glass ionomer cements and composite in function of the time and different storage solutions, considering the dinamic of caries process (pH-cycling). The materiaIs used were: Chelon Fil-ESPE (CHE), Vitremer-3M (VIT), Variglass-DENTSPL Y (V AR), DyractDENTSPL Y (DYR) and Tetric-VIV ADENT (TET). Eighteen cilindrical samples (area=1.65 cm2) of each material were prepared; each sample was then suspended individually in a plastic tube containing 2 ml of each studied solution (6 samples for each solution). The studied solutions were deionized water, artificial saliva and pH cycling, remaining 6h in desmineralization solution (Ca and P 2.0 mM, pH 4.3) and then for a period of 18h in remineralization solution (Ca 1.5mM, P 0.9mM, pH 7.0). AlI solutions were changed daily during 15 days. Fluoride releasing was determined after buffering the solution with equal volume of TISAB. For the f1uoride analysis it was used a f1uoride electrode, Orion 96-09, and an ionalyser Orion EA 940. The f1uoride released (mean :t standard error) in JlgF/cm2 were: in de ionized CHE=7 . 617 0:t0. 7 319 VIT=5.9095:t0.7939 water V AR=2.7154:t0.2463 c, DYR=I.4973:tO.l699 d, TET=0.136l:t:0.0162 e; in artificial saliva- VIT=3.1330:t0.3601 a, CHE=I,2605:t0.0842 b, DYR=1.2001:t0.0519 b, V AR=0.7997:t0.0981 c, T=0,0741:t0.0038 d; and in pH cycling- VIT=12.2727:t1.1577 a, CHE=8.3472:t0.5132 b, DYR=7.8196:t0.6534 c, VAR=6.172S:t0.2447 d, TET=0.2777:t0.0234 e. Means followed by different letters were significant (5%).The data suggest that the comparison of fluoride releasing from dental materiais can change when the media are considered. / Mestrado / Materiais Dentarios / Mestre em Ciências
68

Estudo comparativo da forca de tração desenvolvida pelas cadeias elastomericas nacionais e importadas

Spiegel, Alfredo A 13 July 2018 (has links)
Orientador: Simonides Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia / Made available in DSpace on 2018-07-13T23:08:09Z (GMT). No. of bitstreams: 1 Spiegel_AlfredoA_D.pdf: 1644785 bytes, checksum: 4378581566ca76019e1746744942593b (MD5) Previous issue date: 1990 / Resumo: Este trabalho teve como objetivo comparar "in vitro" as forças de tração exercidas pelas cadeias elastoméricas em função do tempo de distensão. Foram usados 4 tipos comerciais de cadeias elastoméricas, dois de fabricação nacional (Tecnident, tipos Cristal e Cinza) e dois de fabricação estrangeira ...Observação: O resumo, na íntegra poderá ser visualizado no texto completo da tese digital / Abstract: The objective of this work was to compare "in vitro" the traction force produced by the elastomeric chains considering the extension time. Four commercial types of elastomeric chains were used, two Brazilian (Tecnident, types Clear and Gray) and two foreign ones ...Note: The complete abstract is available with the full electronic digital thesis or dissertations / Doutorado / Ortodontia / Mestre em Ciências
69

Influencia de metodos endurecedores sobre algumas propriedades fisicas e na formação cristalina dos gessos tipo IV

Pipolo, Julita de Campos 23 December 1992 (has links)
Orientador: Luiz Antonio Ruhnke / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-17T08:53:10Z (GMT). No. of bitstreams: 1 Pipolo_JulitadeCampos_M.pdf: 2585403 bytes, checksum: bda2967414ed3d8090aa1c493cbc2423 (MD5) Previous issue date: 1992 / Resumo: Os testes de alteração dimensional de presa, resistencia a abrasão, dureza superficial e resistencia a compressão, e os aspectos cristalinos dos gessos Tipo IV (Vel-Mix, Suprastone, Durone e Herostone) foram verificados sob a influencia da solução endurecedora e imersão em oleo mineral ¿Observação: O resumo, na íntegra poderá ser visualizado no texto completo da tese digital / Abstract: Four gypsum brands Type IV (Vel-Mix, Suprastone, Durone, and Herostone) were submitted to the setting methods hardness solution and mineral oil imersion to determine the setting expantion, abrasion resistance, surface hardness and compressive strength, and crystalin aspects ...Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Materiais Dentarios / Mestre em Ciências
70

Resistencia flexural de ligas do sistema Co-Cr antes e apos a refusão submetidas ou não a soldagem

Henriques, Guilherme Elias Pessanha, 1968- 18 July 2018 (has links)
Orientador: Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-18T10:00:07Z (GMT). No. of bitstreams: 1 Henriques_GuilhermeEliasPessanha_M.pdf: 3082477 bytes, checksum: 9387401241e8fa339536480dc617cfc9 (MD5) Previous issue date: 1993 / Resumo: O objetivo deste trabalho foi avaliar a resistência flexural das ligas do sistema Co-Cr Dentorium, Duracrom e Steeldent, disponíveis comercialmente, submetendo-as ou não à soldagem, utilizando amostras confeccionadas com liga nova exclusivamente ou mistura de proporções iguais de ligas nova e previamente fundida. Foram confeccionadas vinte amostras com formato em halteres, para cada uma das ligas avaliadas, divididas em quatro grupos, seguindo o critério a seguir: liga nova sem solda; liga nova/refundida sem solda; liga nova com solda; e, liga nova/refundida com solda. As amostras foram fundidas mediante a utilização de fonte elétrica de arco voltaico de carbono e para o procedimento de soldagem, foi utilizada liga para solda de alta temperatura à base de Co-Cr, fundida sob chama redutora de maçarico de oxiacetileno, estando as partes a serem unidas, distantes 0,4 mm entre si. Para a avaliação da resistência flexural, as amostras foram submetidas à carga perpendicular de compressão fornecida por máquina de teste universal, com velocidade de 200 Kgf /min. Posteriormente, a superfície de fratura das amostras, foi analisada sob microscopia eletrônica de varredura. Com base nos resultados obtidos, verificamos que: a) as ligas Dentorium e Steeldent, tanto na condição de nova, quanto na condição de misturadas, não mostraram diferenças estatisticamente significativas em termos de resistência flexural; b) a liga Duracrom registrou redução nos valores de resistência flexural quando misturada com ligas nova e refundida; c) para as três ligas avaliadas, tanto na condição de nova como na condição de misturadas, houve redução nos valores de resistência flexural para aproximadamente 1/4 daqueles obtidos com as amostras livres de solda / Abstract: The purpose of this investigation was to determine the flexural strength of Dentorium, Duracrom and Steeldent, commercially available Co-Cr based alloys, subdued or not to soldering procedure, using only new alloy or a mixture of new and previously casted alloy. Twenty dumb-shaped specimens were manufactured for each one of the alloys, divided into four groups as the following rule: new alloy without soldering procedure; new alloy/casted alloy combination without soldering procedure; new alloy with soldering procedure; and, new alloy/casted alloy combination with soldering procedure. The specimens were cast with carbon voltaic arc as the electric heat source and for the soldering procedure, it was used high-temperature Co-Cr solder alloy, melted with the reducing flame of a oxyacetilene torch as the heat source, while the gap distance was maintained at 0.4 mm. To evaluate the flexural strength, the specimens were submited to perpendicular compression stress provided by the universal testing machine, with a c:ross-head speed of 200 Kgf/min. After that, the fracture surfaces were observed under scanhing electron microscopy. Related to the results, it was verified that: a) Dentorium and Steeldent alloys, neither as one-half new nor as a half-new/once-used combination, showed no statistically significant differences; b) Duracrom alloy showed reduced flexural strength values when conducted in the as mixed condition; c:) either as new or as mixed, the soldered three alloys displayed reduction of about 1/4 in the flexural strength values, when compared with those obtained with the non soldered ones / Mestrado / Materiais Dentarios / Mestre em Ciências

Page generated in 0.1038 seconds