• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Sistema de medição de demanda e qualidade de energia elétrica / not available

Alexandre de Paula 27 April 2000 (has links)
Os medidores de energia elétrica estão deixando de ser simples instrumentos de aplicação dedicada para se tomarem instrumentos extremamente funcionais. Desde a sua invenção, os medidores vêm sofrendo alterações de acordo com os recursos tecnológicos da época e as exigências de mercado. Atualmente, os processadores digitais de sinais têm sido amplamente empregados nesta área, permitindo a integração de uma série de funções em um único equipamento, além da implementação de algoritmos mais complexos. Estas funções geralmente incluem o cálculo de uma variedade de parâmetros elétricos, comunicação remota, integração com sistemas digitais e outras. Este trabalho apresenta um estudo e o desenvolvimento de um medidor de energia elétrica baseado no processador digital de sinais DSP56002 da Motorola. Entre as funções que são incorporadas ao medidor, destaca-se o monitoramento da qualidade da energia elétrica, visto que esta será uma tendência futura. / Electric energy meters have been changing from simple instruments for dedicated applications to very functional ones. Since their invention, the meters has changed accordingly to the technology resources and market requirements. Nowadays, the digital signal processors have been widely employed in this area, allowing a huge amount of functions to be integrated into only one instrument, besides of the implementation of more complex algorithms. Such functions usually include evaluation of many electrical parameters, remote communication, connection to digital systems and others. This work is about a study and a development of an electric energy meter based on the digital signal processor DSP56002 by Motorola. Among the functions that are incorporated to the meter, it points out the monitoring of electric power quality, once it will be a future trend.
2

Sistema de medição de demanda e qualidade de energia elétrica / not available

Paula, Alexandre de 27 April 2000 (has links)
Os medidores de energia elétrica estão deixando de ser simples instrumentos de aplicação dedicada para se tomarem instrumentos extremamente funcionais. Desde a sua invenção, os medidores vêm sofrendo alterações de acordo com os recursos tecnológicos da época e as exigências de mercado. Atualmente, os processadores digitais de sinais têm sido amplamente empregados nesta área, permitindo a integração de uma série de funções em um único equipamento, além da implementação de algoritmos mais complexos. Estas funções geralmente incluem o cálculo de uma variedade de parâmetros elétricos, comunicação remota, integração com sistemas digitais e outras. Este trabalho apresenta um estudo e o desenvolvimento de um medidor de energia elétrica baseado no processador digital de sinais DSP56002 da Motorola. Entre as funções que são incorporadas ao medidor, destaca-se o monitoramento da qualidade da energia elétrica, visto que esta será uma tendência futura. / Electric energy meters have been changing from simple instruments for dedicated applications to very functional ones. Since their invention, the meters has changed accordingly to the technology resources and market requirements. Nowadays, the digital signal processors have been widely employed in this area, allowing a huge amount of functions to be integrated into only one instrument, besides of the implementation of more complex algorithms. Such functions usually include evaluation of many electrical parameters, remote communication, connection to digital systems and others. This work is about a study and a development of an electric energy meter based on the digital signal processor DSP56002 by Motorola. Among the functions that are incorporated to the meter, it points out the monitoring of electric power quality, once it will be a future trend.
3

Microgeração solar fotovoltaica conectada à rede: análise da qualidade da energia / Solar grid-connected photovoltaic microgeneration: energy quality analysis

Santiago, Gregory Luid Souza 21 February 2017 (has links)
Submitted by Lara Oliveira (lara@ufersa.edu.br) on 2017-06-29T18:40:34Z No. of bitstreams: 1 GregoryLSS_DISSERT.pdf: 2365446 bytes, checksum: d4abe11e0270841ffc2cbf5442616e03 (MD5) / Rejected by Vanessa Christiane (referencia@ufersa.edu.br), reason: Corrigir referência. on 2017-07-03T12:21:23Z (GMT) / Submitted by Lara Oliveira (lara@ufersa.edu.br) on 2017-07-04T14:44:36Z No. of bitstreams: 1 GregoryLSS_DISSERT.pdf: 2365446 bytes, checksum: d4abe11e0270841ffc2cbf5442616e03 (MD5) / Approved for entry into archive by Vanessa Christiane (referencia@ufersa.edu.br) on 2017-07-04T16:49:00Z (GMT) No. of bitstreams: 1 GregoryLSS_DISSERT.pdf: 2365446 bytes, checksum: d4abe11e0270841ffc2cbf5442616e03 (MD5) / Approved for entry into archive by Vanessa Christiane (referencia@ufersa.edu.br) on 2017-07-04T16:58:35Z (GMT) No. of bitstreams: 1 GregoryLSS_DISSERT.pdf: 2365446 bytes, checksum: d4abe11e0270841ffc2cbf5442616e03 (MD5) / Made available in DSpace on 2017-07-04T16:58:47Z (GMT). No. of bitstreams: 1 GregoryLSS_DISSERT.pdf: 2365446 bytes, checksum: d4abe11e0270841ffc2cbf5442616e03 (MD5) Previous issue date: 2017-02-21 / Distributed photovoltaic systems currently have a great potential for growth, due to several factors that make it quite attractive, among them: tariff parity reached in the coming years in some countries, reduction of installation costs, government incentives, and sector regulation, among others. Since these are relatively new types of systems, many researches have been carried out to study the behavior of a distributed photovoltaic generation system connected to the distribution grid. In this sense, the main objective of this work is to analyze the impact generated in energy quality by the installation of a Grid-Connected Photovoltaic System (GCPV) installed in UFERSA, located in Mossoró/RN. Through the evaluation of the main parameters of energy quality generated by the GCPV, it was verified that the installation of a distributed photovoltaic system connected at low voltage causes small changes in some parameters, such as elevation in the steady state voltage, reduction of the power factor of the installation and increase in the value of the total harmonic distortion rate of current. In the work in question, all variations found did not exceed the limits established by the current regulations. It was also verified that the installation of the GCPV caused a daily reduction of up to 38% in the average active energy consumed, considering the phase in which the system is interconnected / Os sistemas fotovoltaicos distribuídos possuem atualmente um grande potencial de crescimento, devido a diversos fatores que o tornam bastante atraentes, dentre eles: paridade tarifária sendo alcançada nos próximos anos em alguns países, redução dos custos de instalação, incentivos governamentais, regulação do setor, entre outros. Por tratar-se de tipos de sistemas relativamente novos, muitas pesquisas têm sido desenvolvidas no intuito de estudar o comportamento de um sistema de geração fotovoltaica distribuída, conectado à rede elétrica de distribuição. Neste sentido, o presente trabalho tem como objetivo principal analisar o impacto gerado na qualidade de energia pela instalação de um Sistema Fotovoltaico Conectado à Rede (SFCR) instalado na UFERSA, localizada em Mossoró/RN. Através da avaliação dos principais parâmetros de qualidade de energia gerados pelo SFCR verificou-se que a instalação de um sistema fotovoltaico distribuído conectado em baixa tensão provoca pequenas alterações em alguns parâmetros, tais como: elevação na tensão de regime permanente, redução do fator de potência da instalação e acréscimo no valor da taxa de distorção harmônica total de corrente. No trabalho em questão, todas as variações constatadas não ultrapassaram os limites estabelecidos pelas normas vigentes. Constatou-se, ainda, que a instalação do SFCR provocou redução diária de até 38% na energia ativa média consumida, considerando a fase na qual o sistema está interconectado / 2017-06-29

Page generated in 0.0882 seconds