• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 3
  • Tagged with
  • 7
  • 7
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Remobilisation of heavy metals from sediments using aminopolycarboxlyic acids

Fang, Bin. January 2005 (has links)
Thesis (Ph. D.)--University of Sydney, 2005. / Title from title screen (viewed 21 May 2008). Submitted in fulfilment of the requirements for the degree of Doctor of Philosophy to the Centre for Heavy Metals Research, School of Chemistry, School of Chemistry. Includes bibliographical references. Also available in print form.
2

Sedimentation patterns and mechanisms of contaminant transport in Lough Neagh, Northern Ireland

Douglas, Richard W. January 1998 (has links)
No description available.
3

Extant benthic Foraminifera from two bays along the SW coast of South Africa, with a comment about their use as indicators of pollution

Toefy, Rashieda January 2010 (has links)
<p>The results of the multivariate analyses suggest that most of the variation in the composition of the samples was of an intra-sample nature, illustrating large scale patchiness in foraminiferal distribution. There were, however, definite differences between communities around Robben Island and in St Helena Bay, and least variation was found between the control and pipeline sites, and between the stations of each site. When the trace metal concentrations and the percentage nitrogen increased, the richness, diversity and abundance of foraminifera tended to decrease. Sediment grain size positively affected abundance but negatively affected diversity and richness. In both areas mean grain size did not, however, appear to play a very large role in influencing diversity. Cadmium, copper, chromium, the percentage nitrogen and the mean grain size were identified as the most important variables influencing the community structure by the BIOENV BEST routine in PRIMER. The trace metals and percentage nitrogen only had negative effects on the diversity and abundance as well as on the abundance of the dominant genera, whereas the mean grain size had variable effects.</p>
4

Extant benthic Foraminifera from two bays along the SW coast of South Africa, with a comment about their use as indicators of pollution

Toefy, Rashieda January 2010 (has links)
<p>The results of the multivariate analyses suggest that most of the variation in the composition of the samples was of an intra-sample nature, illustrating large scale patchiness in foraminiferal distribution. There were, however, definite differences between communities around Robben Island and in St Helena Bay, and least variation was found between the control and pipeline sites, and between the stations of each site. When the trace metal concentrations and the percentage nitrogen increased, the richness, diversity and abundance of foraminifera tended to decrease. Sediment grain size positively affected abundance but negatively affected diversity and richness. In both areas mean grain size did not, however, appear to play a very large role in influencing diversity. Cadmium, copper, chromium, the percentage nitrogen and the mean grain size were identified as the most important variables influencing the community structure by the BIOENV BEST routine in PRIMER. The trace metals and percentage nitrogen only had negative effects on the diversity and abundance as well as on the abundance of the dominant genera, whereas the mean grain size had variable effects.</p>
5

Quantificação de metais em aguas e sedimentos do reservatorio Billings por fluorescencia de raios X com reflexão total e radiação Sincrotron (SR-TXRF) / Quantification of metals in water and sediments of the Billlings dam by Synchronton radiation total reflection X-Ray fluorescence (SR-TXRF)

Sampaio, Sergio Arnaud 26 February 2007 (has links)
Orientador: Silvana Moreira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-10T23:35:00Z (GMT). No. of bitstreams: 1 Sampaio_SergioArnaud_M.pdf: 1857794 bytes, checksum: b5584970c1ca196d93e07f5d3ea81396 (MD5) Previous issue date: 2007 / Resumo: A Represa Billings é o maior reservatório de água da região metropolitana de São Paulo, com aproximadamente 100 km² em espelho de água. Sua bacia hidrográfica ocupa mais de 500km² em seis municípios da região. Ao seu redor concentra-se o maior parque industrial da América do Sul e somente suas margens são ocupadas por quase um milhão de habitantes. A qualidade de suas águas é, portanto, motivo constante de preocupação de toda a sociedade. Neste trabalho aplica-se a Espectrometria de Fluorescência de Raios X, com Reflexão Total e excitação por Radiação Síncrotron (SR-TXRF), para a identificação e quantificação de metais em águas e sedimentos da Represa Billings. Foram quantificados os metais Cr, Ni, Cu, Zn e Pb, freqüentemente investigados em trabalhos na área ambiental, já que são largamente usados em processos industriais e estão presentes em vários produtos de consumo doméstico. Para o trabalho de campo, foram coletadas amostras em dezoito pontos, incluídas as margens e a porção central da represa, localizados em regiões com ocupação residencial e industrial, como também em regiões preservadas, próximos de pontos de monitoramento adotados pela Companhia de Tecnologia de Saneamento Ambiental do Estado de São Paulo (CETESB). As amostras de água e de sedimentos, bem como as amostras certificadas e padrões, foram analisadas no Laboratório Nacional de Luz Síncrotron ¿ LNLS situado no pólo de alta tecnologia, em Campinas-SP. Foi estabelecida uma comparação entre as concentrações de metais obtidas e os valores de referência para águas e para sedimentos, recomendados pela legislação em vigor. Os resultados obtidos indicam concentrações acima dos valores permitidos para o cobre, generalizada para todos os locais de amostragem, como também para o chumbo na grande maioria desses locais. Os demais metais estudados também apresentaram concentrações acima do permitido para alguns dos pontos de amostragem. O trabalho destaca as vantagens e os aspectos relevantes da técnica de análise (SR-TXRF), considerada como não destrutiva e com baixos limites de detecção (partes por bilhão). Outras vantagens são: a sensibilidade analítica para uma ampla faixa de elementos, com um preparo simples e rápido de amostras e facilidade de operação, e que por isso tem apresentado grande desenvolvimento nos últimos anos, com crescente aceitação da comunidade científica. A finalidade de contexto social é contribuir para a preservação dos mananciais locais e o aproveitamento racional de suas águas / Abstract: The Billings dam is the largest water reservatory in the metropolitan region of Sao Paulo, with approximately 100 km2 of area. Its watershed takes up more than 500 km2 in 6 counties of the region. Around the dam is located the largest industrial region of South America and only its borders have about 1 million inhabitants. The water quality is a constant concern to society. On this study, it is applied the synchrotron radiation total reflection X-ray fluorescence (SRTXRF) analysis for identification and quantification of metals in water and sediments of the Billings dam. Metals such as Cr, Ni, Cu, Zn and Pb were analyzed and investigated by environmental work tasks, as they are largely used in industrial processes and are present in various domestic consumers¿ products. As far as experimental work, samples were collected in 18 locations, including the borders and in the central part of the dam, which were located in both residential and industrial regions, as well as in preserved regions, near the places where monitoring was adopted by the Technology and Environmental Company of São Paulo State (CETESB). The water and sediment samples, as well as the certified ones were analyzed in the Brazilian Synchrotron Light Laboratory (LNLS) located in the high technology pole in Campinas, SP. A comparison was established between the metal concentration obtained and the reference values for water and sediments, recommended by Brazilian laws. The results registered a concentration higher than permissive values for Cu, generalized to all sample locations, as well as to Pb in the majority of these places. Other metals studied also showed a concentration higher than permissive values in some points. The job features the advantages and relevant aspects of the SR-TXRF technique. Advantages as not destructive, with low detection limits, high sensitivity for several elements, simple and quick sample preparation, ease operation among others) that shows great development in the past years, with a growing acceptance in the scientific community. The purpose within the social context is to contribute to the local water sources preservation and the rational usage of its waters / Mestrado / Recursos Hidricos / Mestre em Engenharia Civil
6

Emprego de análise por injeção seqüencial (SIA) com detecção eletroquímica na determinação de metais pesados extraíveis de sedimentos / The use of sequential injection analysis with electrochemical detection for determination of heavy metals extractable from sediments

Silva, Clóvis Lúcio da 26 March 1999 (has links)
Estudou-se a especiação dos metais pesados (Cu, Cd, Cr, Zn, Pb e Ni) em sedimentos do rio Tietê, coletados nos reservatórios de Rasgão, Tecelagem e Barra Bonita. Para isto, adotou-se o protocolo de extração seqüencial proposta por Community Bureau of Reference (BCR), que consiste em três etapas de tratamento, as soluções extratores utilizados foram: etapa 1, solução de ácido acético 0,11 mol/L; Etapa 2, solução de cloridrato de hidroxilamina 0,1 mol/L pH 2 (ajustado com HNO3); Etapa 3, ataque com peróxido de hidrogênio em meio ácido e posterior extração dos metais com solução de acetato de amônio pH 2 (ajustado com HNO3). Nas mesmas amostras efetuou-se uma extração com ácido clorídrico 0,1 mol/L, no sentido de avaliar a concentração de metais potencialmente biodisponíveis. Realizou-se ainda a determinação do teor total de metais. Tanto a extração seqüencial como a extração parcial em ácido diluído foram conduzidas em ambientes anaeróbico (mantendo o EH da amostra) e aeróbicos (após secagem em estufa - simulando material dragado e depositado às margens do rio). As concentrações dos metais presentes nos extratos foram determinadas através das técnicas de absorção atômica, espectrometria de emissão atômica, voltametria de redissolução anódica com eletrodo de gota pendente e a técnica proposta por este trabalho, voltametria de redissolução anódica com eletrodo de filme de mercúrio acoplada ao sistema de injeção seqüencial. A técnica de voltametria de redissolução anódica acoplada ao sistema de injeção sequencial apresentou vantagens em relação a voltametria de redissolução com eletrodo de gota pendente, apresentando maior reprodutibilidade e sensibilidade, redução do tempo de análise e consumo de reagentes, e completa automação dos parâmetros instrumentais, como: vazão, número de reagentes, volumes e seqüência dos reagentes aspirados. / Speciation of heavy metals (Cu, Pb, Cd, Zn, Ni and Cr) in sediments of the Tietê river (SP), collected at Rasgão, Tecelagem e Barra Bonita reservoirs, was studied by the sequential extraction protocol proposed by the Community Bureau of Reference (BCR). This protocol is composed of three steps, that use the following reagent extractors. Step1: 0,11 mol/L acetic acid. Step 2: Hydroxylamine hydrochloride, acidified to pH 2 with nitric acid. Step 3: Oxidation with acidified 30 % (v/v) hydrogen peroxide followed by extraction with 1mol/L ammonium acetate acidified to pH 2 with nitric acid. Samples were also extracted with 0.10 mol/l hydrochloric acid in order to evaluate the bioavailable metal concentrations. The total concentration of metals was also determined. The sequential extraction and the extraction with hydrochloric acid were performed in anoxic (keeping the negative Eh of samples, as in the time of sampling) and oxidant conditions (after drying samples at 60&#186;C in the atmosphere, simulating dredged material). Metal determination was performed by Flame Atomic Absorption Spectrometry (FAAS), Induced Coupled Plasma-Atomic Emission Spectrometry (ICP-EAS), Anodic Stripping Voltammetry with the Mercury Hanging Drop Electrode (ASV-HMDE), and the technique proposed in this work: ASV automated by Sequential Injection (ASV-SI) using the Thin Film Mercury Electrode (TFME). The proposed technique presented improved reproducibility and shorter time of analysis in comparison to conventional ASV-HMDE. In addition, the ASV-SI permits easy and fast change of operational parameters such as flow rate and sample volume, that have direct influence on the deposition time.
7

Emprego de análise por injeção seqüencial (SIA) com detecção eletroquímica na determinação de metais pesados extraíveis de sedimentos / The use of sequential injection analysis with electrochemical detection for determination of heavy metals extractable from sediments

Clóvis Lúcio da Silva 26 March 1999 (has links)
Estudou-se a especiação dos metais pesados (Cu, Cd, Cr, Zn, Pb e Ni) em sedimentos do rio Tietê, coletados nos reservatórios de Rasgão, Tecelagem e Barra Bonita. Para isto, adotou-se o protocolo de extração seqüencial proposta por Community Bureau of Reference (BCR), que consiste em três etapas de tratamento, as soluções extratores utilizados foram: etapa 1, solução de ácido acético 0,11 mol/L; Etapa 2, solução de cloridrato de hidroxilamina 0,1 mol/L pH 2 (ajustado com HNO3); Etapa 3, ataque com peróxido de hidrogênio em meio ácido e posterior extração dos metais com solução de acetato de amônio pH 2 (ajustado com HNO3). Nas mesmas amostras efetuou-se uma extração com ácido clorídrico 0,1 mol/L, no sentido de avaliar a concentração de metais potencialmente biodisponíveis. Realizou-se ainda a determinação do teor total de metais. Tanto a extração seqüencial como a extração parcial em ácido diluído foram conduzidas em ambientes anaeróbico (mantendo o EH da amostra) e aeróbicos (após secagem em estufa - simulando material dragado e depositado às margens do rio). As concentrações dos metais presentes nos extratos foram determinadas através das técnicas de absorção atômica, espectrometria de emissão atômica, voltametria de redissolução anódica com eletrodo de gota pendente e a técnica proposta por este trabalho, voltametria de redissolução anódica com eletrodo de filme de mercúrio acoplada ao sistema de injeção seqüencial. A técnica de voltametria de redissolução anódica acoplada ao sistema de injeção sequencial apresentou vantagens em relação a voltametria de redissolução com eletrodo de gota pendente, apresentando maior reprodutibilidade e sensibilidade, redução do tempo de análise e consumo de reagentes, e completa automação dos parâmetros instrumentais, como: vazão, número de reagentes, volumes e seqüência dos reagentes aspirados. / Speciation of heavy metals (Cu, Pb, Cd, Zn, Ni and Cr) in sediments of the Tietê river (SP), collected at Rasgão, Tecelagem e Barra Bonita reservoirs, was studied by the sequential extraction protocol proposed by the Community Bureau of Reference (BCR). This protocol is composed of three steps, that use the following reagent extractors. Step1: 0,11 mol/L acetic acid. Step 2: Hydroxylamine hydrochloride, acidified to pH 2 with nitric acid. Step 3: Oxidation with acidified 30 % (v/v) hydrogen peroxide followed by extraction with 1mol/L ammonium acetate acidified to pH 2 with nitric acid. Samples were also extracted with 0.10 mol/l hydrochloric acid in order to evaluate the bioavailable metal concentrations. The total concentration of metals was also determined. The sequential extraction and the extraction with hydrochloric acid were performed in anoxic (keeping the negative Eh of samples, as in the time of sampling) and oxidant conditions (after drying samples at 60&#186;C in the atmosphere, simulating dredged material). Metal determination was performed by Flame Atomic Absorption Spectrometry (FAAS), Induced Coupled Plasma-Atomic Emission Spectrometry (ICP-EAS), Anodic Stripping Voltammetry with the Mercury Hanging Drop Electrode (ASV-HMDE), and the technique proposed in this work: ASV automated by Sequential Injection (ASV-SI) using the Thin Film Mercury Electrode (TFME). The proposed technique presented improved reproducibility and shorter time of analysis in comparison to conventional ASV-HMDE. In addition, the ASV-SI permits easy and fast change of operational parameters such as flow rate and sample volume, that have direct influence on the deposition time.

Page generated in 0.0732 seconds