• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • Tagged with
  • 12
  • 12
  • 8
  • 6
  • 6
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Desenvolvimento e avaliação da estabilidade de formulações cosméticas anticelulíticas contendo o extrato comercial de Trichilia catiguá Adr. Juss (e) Ptychopetalum olacoides Bentham, padronizado em flavonóides totais / Development and stability assay of anticelulitic cosmetic formulations containing the Trichilia catigua Adr. Juss (e) Ptychopetalum olacoides Bentham commercial extract, standardized in total flavonoids

André Rolim Baby 26 July 2005 (has links)
A hidrolipodistrofia ginóide, popularmente denominada de celulite, é caracterizada como um processo distrófico que produz alterações estruturais dos elementos presentes na pele, como: modificações no tecido conjuntivo, comprometimento da microcirculação periférica cutânea, hipertrofia e hiperplasia dos adipócitos e edema. Os flavonóides são utilizados como substâncias ativas em preparações anticelulíticas por reduzirem a permeabilidade capilar. Os objetivos estabelecidos para esta pesquisa foram: (1) desenvolver emulsões cosméticas com finalidades anticelulíticas; (2) validar metodologia analítica para o doseamento de flavonóides totais, equivalentes em rutina, por espectrofotometria na região do ultravioleta; (3) avaliar a estabilidade física, físico-química e química das formulações. Formulações cosméticas anticelulíticas foram desenvolvidas contendo o extrato vegetal comercial de Trichilia catiguá Adr. Juss (e) Ptychopetalum olacoides Bentham (Slimbuster® H1), padronizado em flavonóides totais, equivalentes em rutina, e avaliadas quanto à estabilidade física, físico-química e química. Para sua quantificação, o método espectrofotométrico na região do ultravioleta a 361,0 nm foi empregado, comparando-se com rutina padrão secundário de referência (T = 96,1%). A avaliação da estabilidade envolveu três condições distintas de temperatura (5,0 + 0,5; 24 + 2 e 40,0 + 0,5 °C), pelo período de três meses, e as variáveis analisadas foram as características organolépticas, valor de pH, viscosidade aparente e teor de flavonóides totais. A metodologia foi validada quanto à linearidade, limites de detecção e quantificação, especificidade e pesquisa de interferentes, recuperação do padrão, precisão e exatidão intra e inter-dias. Os resultados da estabilidade indicaram que o teor de flavonóides totais, equivalentes em rutina, sofreu decaimento inferior a 10% nas condições de exposição à luz solar direta e/ou indireta, à temperatura ambiente (24 + 2 °C) e de refrigerador (5,0 + 0,5 °C), sendo que a 40,0 + 0,5 °C, condição de estufa, ocorreu redução de, aproximadamente, 35%. / Gynoid hydrolipodystrophy, popularly known as cellulite, is characterized as a dystrophic process that generates structural alterations of skin elements, as: connective tissue modifications, cutaneous microcirculation abnormalities, hypertrophy and hyperplasia of adipocytes and edema. Flavonoids are employed as raw materials in anticellulitic products by their capability to reduce capillary permeability. The objectives established for this research were: (1) development of anticellulitic cosmetic emulsions; (2) analytical method validation for total flavonoids, expressed in rutin, by ultraviolet spectrophotometry; (3) physical, physicochemical and chemical stability assay for the preparations. Anticellulitic cosmetic formulations containing the Trichilia catigua Adr. Juss (and) Ptychopetalum olacoides Bentham commercial extract (Slimbuster® H1), standardized in total flavonoids, expressed in rutin, were developed and their physical, physicochemical and chemical stability was assessed. Flavonoids were quantified within the ultraviolet spectrophotometric method at 361.0 nm as rutin equivalents by comparison with secondary standard rutin (T = 96.1%). Stability assay was conducted in three temperature conditions (5.0 + 0.5; 24 + 2 e 40.0 + 0.5 °C) and the following parameters were analyzed: aspect, color and odor, pH and apparent viscosity values and flavonoid content. Analytical methodology was validated determining linearity, limits of detection and quantification, specificity and interferent assay, recovery and intra and inter-run precision and accuracy. Results from stability evaluation have indicated decrease of flavonoid content inferior than 10% at sunlight exposure (room temperature, 24 + 2 °C) and at 5.0 + 0.5 °C; high temperature (40.0 + 0.5 °C) has reduced the flavonoid content at, approximately, 35%.
12

Estimativa dos esforços eletromecânicos em transformadores submetidos a um curto-circuito trifásico

Rosentino Junior, Arnaldo José Pereira 09 July 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Power transformers are essential and a large part of the asset cost structure of the electrical power system. When they present any defect or failure, it will be required high costs to repair or replace them, due their commercial costs and by the capability loss to transmit power during a period of time. Generally, transformer failure can occur as a result of the weakness insulation caused by the electrochemical processes involving the cooling liquid (oil), by vibrations due the electromagnetic forces in normal operation, i.e., steady state, and also by winding deformation as the result of short-circuits. It is expected that a transformer will experience and survive a number of short circuits during its service life. But one such event will cause some slight winding movement, which can gradually increasing and the ability of the transformer to withstand further electromechanical forces will be then reduced. It is therefore very important to check the mechanical condition of transformers periodically, particularly for older units, to provide an early warning of an impending catastrophic failure. Thus a specialist technique is required for the monitoring and assessment of mechanical condition of winding transformer. Despite designers and manufacturers, as well as the operation and maintenance technicians of power supply companies worry about this subject, new methodologies and tools to assess the strength effects as the result of short circuits in transformers are still necessaries. So, this work proposes to know the strength characteristics caused by the radial and axial forces in winding transformers. In this context, it will be presented different strengths that can occur in winding transformer, identifying the principal failures as the result of these stresses. Besides, it will be developed an analytical method to evaluate the forces and stresses in winding three phase transformer under a three phase short circuit. Finally, the analytical method results will be compared with a computer simulation based in time domain using the software FEMM, which applies the finite element method. / Transformadores de potência são equipamentos essenciais aos sistemas elétricos e também um de seus componentes de maior preço. Quando estes equipamentos se danificam ou apresentam algum tipo de falha, o seu reparo ou até mesmo sua substituição demanda altíssimos custos financeiros, tanto pelo alto valor comercial destes equipamentos como pela perda temporária da capacidade de transmissão de energia elétrica. Muitas falhas destes equipamentos devem-se à redução da suportabilidade da isolação dos seus condutores/enrolamentos causado pelos fenômenos eletroquímicos do líquido de resfriamento (óleo), pelas vibrações produzidas pelas forças eletromecânicas durante a sua operação normal, ou seja, em regime permanente, e também pelas deformações dos enrolamentos causadas pelas altas correntes de curto-circuito. Espera-se, no entanto, que um transformador suporte um determinado número de curtos-circuitos durante seu tempo de operação. No entanto, verifica-se que cada evento poderá provocar pequenos deslocamentos relativos nos enrolamentos, os quais podem aumentar cumulativamente, reduzindo desta forma a capacidade do transformador de suportar novos esforços eletromecânicos. Neste contexto, torna-se importante a verificação periódica das suas condições mecânicas, principalmente nas unidades com muito tempo de operação, de forma a se obter subsídios para impedir falhas catastróficas. O emprego de técnicas especiais é requerido para o monitoramento e avaliação das condições mecânicas do enrolamento de um transformador. Apesar de este assunto ser uma preocupação constante dos projetistas e fabricantes de transformadores, bem como dos profissionais de manutenção e operação das empresas de energia elétrica, há certa carência de metodologias e ferramentas consistentes para se avaliar os efeitos dos esforços mecânicos decorrentes das elevadas correntes transitórias sobre estes equipamentos. Nessa perspectiva, este trabalho tem por meta o entendimento das características dos esforços mecânicos causados pelas forças radiais e axiais nos enrolamentos dos transformadores. Para tanto, esta dissertação mostrará os diferentes tipos de esforços eletromecânicos passíveis de ocorrer nos enrolamentos de um transformador, identificando os principais tipos de falhas provocadas por essas solicitações. Em seguida, será desenvolvida uma metodologia analítica para estimar as forças e estresses nos enrolamentos de um transformador trifásico submetidos a um curto-circuito trifásico. Assim, os valores obtidos pela metodologia analítica serão confrontados com resultados de uma simulação computacional no domínio do tempo utilizando-se o programa FEMM baseado na técnica de elementos finitos. / Mestre em Ciências

Page generated in 0.1288 seconds