• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • 1
  • Tagged with
  • 14
  • 12
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação de massas cardíacas pela ecocardiografia com perfusão em tempo real / Evaluation of cardiac masses by real time perfusion imaging echocardiography

Eliza Kaori Uenishi 11 May 2011 (has links)
Introdução: As massas cardíacas (MC) podem ser tumores, trombos ou pseudotumores. A avaliação da vascularização poderá ser uma ferramenta adicional para o seu diagnóstico diferencial. Neste estudo, demonstrou-se o valor diagnóstico da ecocardiografia com perfusão na caracterização das MC or meio de análises qualitativas e quantitativas de perfusão. Métodos: Estudo prospectivo que envolveu 107 pacientes, classificados em quatro grupos: 33 trombos, 23 tumores malignos (TM), 24 tumores benignos (TB) e 6 pseudotumores; 21 pacientes foram excluídos por não terem diagnóstico definitivo confirmado. A avaliação de perfusão foi realizada pela ecocardiografia com perfusão em tempo real, utilizando contraste à base de microbolhas. Em um grupo selecionado de pacientes (32), o estudo foi complementado com dipiridamol para avaliação da reserva de fluxo da massa. A análise foi feita qualitativa e quantitativamente por dois observadores independentes. Na análise qualitativa, os parâmetros foram: intensidade da perfusão (escore 0 a 3), velocidade do repreenchimento microvascular (escore 0 a 2), padrão de perfusão central ou periférico (escore 0 a 2) e presença de áreas de necrose (escore 0 e 1). Os dois parâmetros de quantificação das massas foram: volume de sangue microvascular (A) e fluxo microvascular regional, que é o produto da velocidade de fluxo () e volume (A). Resultados: Na análise qualitativa, o padrão mais frequente para o grupo trombos foi: sem perfusão (81,9%), sem velocidade de perfusão (81,9%) e sem área de necrose (93,4%); nos tumores, predominou perfusão discreta (62,3%), com velocidade lenta (64,2%) e áreas de necrose (30,2%). Na análise qualitativa, a variação intraobservador para escore de perfusão e de velocidade foi de 20%, para áreas de necrose de 25% e para padrão de perfusão foi de 45%. Na análise quantitativa, o grupo trombos apresentou valores de A e Ax significativamente menores quando comparados ao grupo de tumores: Trombos: A = 0,08 (0,01-0,22dB); Ax = 0,03 (0,010,14dB/s-1); TM: A = 2,78 (1,31-7,0dB); Ax = 2,0 (0,995,58dB/s-1); TB: A = 2,58 (1,24-4,55dB); Ax = 1,18 (0,453,4dB/s-1). Quando comparados apenas os grupos de tumores com o uso de dipiridamol, os TM apresentaram volume sanguíneo microvascular (A) maiores: A = 4,18 (2,14-7,93dB); Ax = 2,46 (1,424,59dB/s-1), TB: A = 2,69 (1,11-4,26dB); Ax = 1,55 (0,555,50dB/s-1). Na análise com a curva ROC, a área sob a curva = 0,95, no parâmetro volume sanguíneo microvascular (A) < 0,65dB na ecocardiografia de perfusão com e sem uso de dipiridamol foi preditor para trombo, bem como o parâmetro fluxo sanguíneo microvascular (Ax) < 0,30dB/s-1, (área sob a curva = 0,94). Para distinguir entre TM de TB, o parâmetro volume sanguíneo microvascular (A), com o uso de dipiridamol > 3,28dB foi preditor de TM (área sob a curva = 0,75). Conclusão: O estudo ecocardiográfico para avaliação da perfusão das MC mostrou que a análise qualitativa é um método diagnóstico rápido e reprodutível para diagnosticar trombos. Os tumores cardíacos apresentam volume microvascular e fluxo sanguíneo regional maior se comparados com os trombos. O uso do dipiridamol foi útil na diferenciação entre os TM e TB / Background: Cardiac masses (CM) can be tumors, thrombi or pseudotumors. Evaluation of their vascularization might be an additional tool to perform a differential diagnosis. In the present study we demonstrated the diagnostic value of perfusion echocardiography for CM characterization, by qualitative and quantitative analyses of perfusion. Methods: We prospectively studied 107 patients, who were classified into 4 groups: 33 thrombus, 23 malignant tumors (MT), 24 benign tumors (BT) and 6 pseudotumors, of which 21 were excluded because no definitive diagnosis could be confirmed. Perfusion evaluation was performed by contrast echocardiography with real time perfusion imaging using microbubbles. A group of patients (32) was selected for a complementary study using dipyridamole to evaluate mass flow reserve. Qualitative and quantitative analyses were performed by two independent observers. Parameters for qualitative analysis were perfusion intensity (0-3 score), microvascular refilling velocity (0-2 score), central or peripheral perfusion pattern (0-2 score), and presence of areas of necrosis (0 or 1 score). The two parameters for quantification of masses were microvascular blood volume (A), and regional microvascular flow which is the product of blood flow velocity and vomume (A). Results: The most frequent pattern for the thrombi group in the qualitative analysis was absence of perfusion (81.9%), followed by no perfusion velocity (81.9%), and no areas of necrosis (93.4%), whilst among tumors there was predominance of discrete perfusion (62.3%), with slowed velocity (64.2%), and areas of necrosis (30.2%). Qualitative analysis, perfusion velocity showed intraobserver variability 20%, presence of areas of necrosis of 25% and perfusion pattern of 45%. In the quantitative analysis, the thrombi group was shown to have A and Ax values significantly smaller compared to the tumor group: Thrombi: A = 0.08 (0.01-0.22dB); Ax = 0.03 (0.010.14dB/s-1); MT: A = 2.78 (1.31-7.0dB); Ax = 2.0 (0.995.58dB/s-1); BT: A = 2.58 (1.24-4.55dB); Ax = 1.18 (0.453.4dB/s-1). When only the tumor groups with the use of dipyridamole were compared, MT was shown to have greater microvascular blood volume (A): A = 4.18 (2.14-7.93dB); Ax = 2.46(1.424.59dB/s-1), BT: A = 2.69 (1.11-4.265dB); Ax = 1.55 (0.555.50dB/s-1). Analysis of the ROC curve showed that an area of 0.95 for a microvascular blood volume of A < 0.65 dB predictive curve on perfusion echocardiography, both with and without dipyridamole, predicts thrombi, and so does a <0.30dB/s-1microvascular blood flow (Ax), area under curve = 0.94. In order to distinguish MT from BT, a >3.28dB microvascular blood volume (A) using dipyridamole was predictor of MT (area under curve = 0.75). Conclusion: The echocardiographic study to evaluate CM perfusion showed that qualitative analysis is reproducible diagnostic approach for diagnosing thrombi. Cardiac tumors show greater microvascular volume and regional blood flow when compared with thrombi. Dipyridamole quantitative stress mass perfusion was useful to differentiate MT from BT
12

[en] LYOPHILIZED MICROFLUIDIC MONODISPERSE MICROBUBBLES AS AN ULTRASOUND CONTRAST AGENT / [pt] MICROBOLHAS MONODISPERSAS MICROFLUÍDICAS LIOFILIZADAS COMO AGENTE DE CONTRASTE DE ULTRASSOM / [fr] MICROBULLES MONODISPERSÉES MICROFLUIDIQUES LYOPHILISÉES COMME AGENT DE CONTRASTE ULTRASONORE

PEDRO NIECKELE AZEVEDO 28 March 2023 (has links)
[pt] Nos últimos anos, as vantagens do uso de agentes de contraste de ultrassom (UCA) com distribuição de tamanho monodisperso foram destacadas. Caracterizadas por um coeficiente de variação (CV) inferior a 5 por cento, as microbolhas monodispersas têm o potencial de melhorar a qualidade das imagens de ultrassom (melhorando a relação sinal/ruído e reduzindo os efeitos de sombra). Também facilita o monitoramento da freqüência de ressonância das microbolhas, abrindo possibilidades nas áreas de imagem molecular e medições de pressão não-invasiva. Além disso, as bolhas monodispersas podem otimizar a entrega de drogas, genes e gases terapêuticos (por exemplo, sonotrombólise, sonoporação, abertura da barreira hemato-encefálica). No entanto, até agora, ao contrário das bolhas polidispersas, a liofilização de populações monodispersas de microbolhas, sem deteriorar sua monodispersividade, continuam sendo um desafio. Assim, hoje, as bolhas monodispersas não podem ser armazenadas nem transportadas. Isto representa um gargalo para seu uso em aplicações clínicas. Tentativas feitas para resolver o problema têm usado solventes tóxicos, levantando questões regulatórias O objetivo do presente trabalho foi de desenvolver uma nova técnica de liofilização para microbolhas monodispersas que não degradassem sua distribuição de tamanho, ou suas propriedades acústicas, sem o uso de solventes tóxicos. Como primeira etapa do projeto, foram fabricados dispositivos microfluídicos com focalização de escoamento (flow-focusing) para produzir microbolhas com distribuição de tamanho altamente monodispersa (CV menor que 5 por cento). Durante esta etapa, foi realizada a otimização da formulação das microbolhas e dos materiais crioprotetores. Foi realizada a caracterização geométrica de duas populações de microbolhas com diâmetros médios de 40 micrômetros e 5 micrômetros . Com o uso de uma câmera de alta velocidade acoplada a um microscópio ótico, imagens de todas as etapas do processo de liofilização das microbolhas foram capturadas e analisadas, visando controlar a distribuição de tamanho e a taxa de produção das microbolhas. As etapas do processo de liofilização consistiram na produção, coleta, congelamento, liofilização e ressuspensão. O desenvolvimento de uma nova técnica de recuperação, onde as microbolhas eram armazenadas em monocamadas, resultou em uma redução drástica da interação entre as bolhas durante a liofilização. Desta forma, foi possível preservar a monodispersão durante o processo de liofilização, resultando em um CV menor que 6 por cento para a população de microbolhas ressuspensas. Os ensaios de microscópio eletrônico de varredura ambiental (ESEM) demonstraram uniformidade nas cascas das microbolhas liofilizadas com uma espessura de parede estimada em 70nm. Na segunda etapa do projeto, foi realizada uma caracterização da resposta acústica de retrodifusão das microbolhas liofilizadas em forma de PVA, em comparação com as microbolhas recém produzidas e as microbolhas polidispersa SonovueTM disponíveis comercialmente. Primeiramente, a resposta acústica de retrodifusão das microbolhas foi avaliada em duas configurações diferentes: a célula centimétrica (recipiente grande - 45mmx10mmx30mm), e o milli-canal (sistema confinado no qual o líquido está em repouso - 10 mmx35 mmx1 mm). Usando um transdutor acústico focalizado com frequência de 2,25MHz, as respostas acústicas das microbolhas, na forma de frequência e amplitude de ressonância fundamental, antes e depois do processo de liofilização, foram comparadas para a população de bolhas de 5 micrômetros de diâmetro. Verificou-se que a variação de amplitude e frequência de ressonância fundamental das bolhas estava dentro da faixa de incerteza experimental, sugerindo que suas propriedades acústicas foram preservadas. Observamos também, de acordo com a literatura, que existe uma dependência linear entre a concentração da população de microbolhas (sem liofilização) e a amplitude do coeficiente de retrodifusão. Posteriormente, foi feita uma comparação da resposta de retrodispersão acústica para bolhas monodispersas e polidispersas. Também, de acordo com a literatura, observamos uma amplitude no sinal de resposta das bolhas monodispersas de 8 a 10 vezes maior que a das bolhas polidispersas, para a mesma concentração in vitro. Também foi possível observar a menor incerteza no monitoramento do pico de ressonância fundamental das bolhas e uma menor largura de banda para a população de bolhas monodispersas. Finalmente, utilizando a abordagem de imagens de matriz universal de ultrassom, desenvolvida no Institut Langevin, a resposta acústica de retrodifusão da população monodispersa liofilizada e polidispersa foi avaliada em um tecido artificial com impedância acústica similar ao tecido humano. Os resultados preliminares reforçam os resultados das medições acústicas de retrodifusão na célula centimétrica e no milicanal, nos quais a população monodispersa apresentou uma largura de banda significativamente reduzida em comparação com a ampla largura de banda da população polidispersa. O presente trabalho apresentou com sucesso uma nova técnica desenvolvida para liofilizar as microbolhas monodispersas sem degradar suas propriedades geométricas e acústicas. Assim, propusemos uma nova geração de agentes de contraste ultrassom na forma de um pó liofilizado estável que pode ser transportado e armazenado por meses e ressuspenso para uso em aplicações clínicas. / [en] In recent years, the advantages of using ultrasound contrast agents (UCA) with monodisperse size distribution have been highlighted. Characterized by a coefficient of variation (CV) lower than 5 percent, monodisperse microbubbles have the potential to improve the quality of ultrasound images (improving signal-to-noise ratio and reducing shadowing effects. It also facilitates microbubble resonance frequency monitoring, opening possibilities in the areas of molecular imaging and non-invasive pressure measurements. In addition, monodisperse bubbles can optimize the drugs, genes, and therapeutic gas delivery (e.g. sonotrombolysis, sonoporation, blood-brain barrier opening). However, thus far, contrarily to polydisperse bubbles, freeze-drying monodisperse populations of fresh microbubbles, without deteriorating their monodispersity, remains a challenge. Thereby, today, monodisperse bubbles can neither be stored nor transported. This represents a bottleneck for their use in clinical applications. Attempts made to solve the problem have used toxic solvents, raising regulatory issues The objective of the present work was to develop a new freeze-drying technique for monodisperse microbubbles that did not degrade their size distribution, or their acoustic properties, without the use of toxic solvents. As the first step of the project, flow-focusing microfluidic devices were fabricated to produce microbubbles with highly monodisperse size distribution (CV less than 5 percent). During this step, the optimization of the microbubble formulation and cryoprotectant materials was performed. Geometric characterization of two of microbubbles with mean diameters of 40 Micrometers and 5 Micrometers was performed. With the use of a high-speed camera coupled to an optical microscope, images of all stages of the freeze-drying process of the microbubbles were captured and analyzed, aiming to control the size distribution and production rate of the microbubbles. The steps of the freeze-drying process consisted of production, collection, freezing, lyophilization, and resuspension. The development of a new retrieval technique, where the microbubbles were stored in monolayers, resulted in a drastic reduction of the interaction between the bubbles during lyophilization. In this way, it was possible to preserve the monodispersity during the freeze-drying process, resulting in a CV less than 6 percent for the resuspended microbubble population. Environmental scanning electron microscope (ESEM) assays demonstrated uniformity in the shells of the freeze-dried microbubbles with an estimated wall thickness of 70nm. In the second stage of the project, a characterization of the backscatter acoustic response of the freeze-dried monodisperse PVA-shelled microbubbles, in comparison with freshly produced microbubbles, and commercially available polydisperse microbubbles SonovueTM was conducted. Firstly, the backscatter acoustic response of the microbubbles was evaluated in two different setups: the centimetric cell (large container - 45mmx10mmx30mm), and the milli-channel (confined system in which the liquid is at rest - 10 mmx35 mmx1 mm). Using a focused acoustic transducer with a frequency of 2.25MHz, the acoustic responses of the microbubbles, in the form of the fundamental resonance frequency and amplitude, before and after the freeze-drying process was compared for the bubble population of 5 Micrometers diameter. It was found that the variation of amplitude and fundamental resonance frequency of the bubbles were within the experimental uncertainty range, suggesting that their acoustic properties were preserved. We also observed, in agreement with the literature, that there is a linear dependence between the concentration of the microbubble population (without freeze-drying) and the amplitude of the backscatter coefficient. Subsequently, a comparison of the acoustic backscatter response was performed for monodisperse and polydisperse bubbles. Also, in agreement with the literature, we observed an amplitude in the response signal of the monodispersed bubbles of 8 to 10 times higher than that for the polydispersed ones, for the same in vitro concentration. It was also possible to observe the lower uncertainty in monitoring the fundamental resonance peak of the bubbles and a smaller bandwidth for the monodispersed bubble population. Finally, using the universal ultrasound matrix imaging approach, developed at Institut Langevin, the backscatter acoustic response of the freeze-dried monodisperse and polydisperse population was evaluated in a phantom mimicking tissue. The preliminary results reinforce the findings from the backscatter acoustic measurements in the centimetric cell and the milli-channel, in which the monodisperse population presented a significantly reduced bandwidth in comparison with the wide bandwidth of the polydisperse population. The present work successfully presented a new technique developed to freezedry monodisperse microbubbles without degrading their geometrical and acoustic properties. Thus, we proposed a new generation of ultrasound contrast agents in the form of a stable freeze-dried powder that can be transported and stored for months and resuspended for use in clinical applications. / [fr] Ces dernieres années, les avantages de l utilisation d agents de contraste ultrasonores (ACU) à distribution de taille monodisperse ont été mis en évidence. Caractérisées par un coefficient de variation (CV) de leur diamètre inférieur à 5 Pour cent, les microbulles monodisperses ont le potentiel d améliorer la qualité des images ultrasonores (amélioration du rapport signal/bruit et réduction des effets d ombre). Elles facilitent également le contrôle de la fréquence de résonance des microbulles, ouvrant des possibilités dans les domaines de l imagerie moléculaire et des mesures de pression non invasives. En outre, les bulles monodisperses peuvent optimiser l administration de médicaments, de gènes et de gaz thérapeutiques (par exemple, sonotrombolyse, sonoporation, ouverture de la barrière hémato-encéphalique). Cependant, jusqu à présent, contrairement aux bulles polydisperses, la lyophilisation de populations monodisperses de microbulles fraiches, sans détérioration de leur monodispersité, reste un défi. Ainsi, aujourd hui, les bulles monodisperses ne peuvent être ni stockées ni transportées. Cela représente un goulot d étranglement pour leur utilisation dans des applications cliniques. Les tentatives faites pour résoudre ce problème ont utilisé des solvants toxiques, ce qui soulève des problèmes de réglementation. L objectif du présent travail était de développer une nouvelle technique de lyophilisation des microbulles monodisperses qui ne dégrade pas leur distribution de taille, ni leurs propriétés acoustiques, et ce sans utiliser de solvants toxiques. La première étape du projet a consisté à fabriquer des dispositifs microfluidiques de focalisation du flux pour produire des microbulles avec une distribution de taille hautement monodisperse (CV moins que 5 Pour cent). Au cours de cette étape, l optimisation de la formulation des microbulles et des matériaux cryoprotecteurs a été réalisée. La caractérisation géométrique de deux microbulles avec des diamètres moyens de 40 micrometres et 5 micrometres a été menée. A l aide d une caméra à haute vitesse couplée à un microscope optique, des images de toutes les étapes du processus de lyophilisation des microbulles ont été capturées et analysées, dans le but de contrôler la distribution de taille et le taux de production des microbulles. Les étapes du processus de lyophilisation comprenaient la production, la collecte, la congélation, la lyophilisation et la remise en suspension. Le développement d une nouvelle technique de récupération, ou les microbulles étaient stockées en monocouches, a permis de réduire considérablement l interaction entre les bulles pendant la lyophilisation. De cette maniere, il a été possible de préserver la monodispersité pendant le processus de lyophilisation, ce qui a permis d obtenir un CV moins que 6 Pour cent pour la population de microbulles remise en suspension. Les analyses au microscope électronique à balayage environnemental (ESEM) ont démontré l uniformité des enveloppes des microbulles lyophilisées avec une épaisseur de paroi estimée à 70nm. Dans la deuxième étape du projet, une caractérisation de la réponse acoustique (en rétrodiffusion) des microbulles monodisperses lyophilisées et enveloppées de PVA a été réalisée et comparée avec celles de microbulles fraichement produites et de microbulles polydisperses disponibles dans le commerce (SonovueTM). Tout d abord, la réponse acoustique en rétrodiffusion des microbulles a été évaluée dans deux configurations différentes : la cellule centimétrique (grand récipient - 45mmx10mmx30mm), et le milli-channel (systeme confiné dans lequel le liquide est au repos - 10 mmx35 mmx1 mm). En utilisant un transducteur acoustique focalisé avec une fréquence de 2.25MHz, les réponses acoustiques des microbulles (fréquence de résonance fondamentale et amplitude) avant et après le processus de lyophilisation ont été comparées pour la population de bulles de 5 micrometres de diamètre. Il a été constaté que la variation de l amplitude et de la fréquence de résonance fondamentale des bulles se situait dans la plage d incertitude expérimentale, ce qui suggère que leurs propriétés acoustiques ont été préservées. Nous avons également observé, en accord avec la littérature, qu il existe une dépendance linéaire entre la concentration de la population de microbulles (sans lyophilisation) et l amplitude du coefficient de rétrodiffusion. Par la suite, une comparaison de la réponse acoustique a été effectuée pour des bulles monodisperses et polydisperses. Aussi, en accord avec la littérature, nous avons observé une amplitude du signal de réponse des bulles monodisperses de 8 à 10 fois supérieure à celle des bulles polydisperses, pour une même concentration in vitro. Il a également été possible d observer une plus faible incertitude dans le suivi du pic de résonance des bulles et une plus petite largeur de bande pour la population de bulles monodisperses. Enfin, en utilisant une approche originale dite d imagerie matricielle par ultrasons, développée à l Institut Langevin, la réponse acoustique de la population lyophilisée monodispersée et polydispersée a été évaluée dans un fantôme simulant les tissus. Les résultats préliminaires renforcent les conclusions des mesures acoustiques menées dans la cellule centimétrique et le canal millimétrique, dans lesquelles la population monodisperse présente une largeur de bande significativement réduite par rapport à la grande largeur de bande de la population polydisperse. Le présent travail a permis le développement d une nouvelle technique pour lyophiliser des microbulles monodispersées sans dégrader leurs propriétés géométriques et acoustiques. Ainsi, nous avons proposé une nouvelle génération d agents de contraste ultrasonores se présentant sous la forme d une poudre lyophilisée stable qui peut être transportée et stockée pendant des mois et remise en suspension pour être utilisée dans des applications cliniques.
13

Avaliação da administração intravenosa de solução salina hipertônica 7,5% como estratégia para melhorar a perfusão do tumor e a entrega de moléculas em modelos tumorais em camundongos / Evaluation of hypertonic saline solution 7,5% intravenous administration as a potential strategy to enhance tumor perfusion as well as molecular delivery in mice tumor models

Gonzalez, Angelica Maria Patiño 20 December 2016 (has links)
A administração intravenosa de solução salina hipertônica (HSS) induz alterações sistêmicas circulatórias como o aumento da pressão arterial e do volume circulante efetivo, além de ter efeitos locais sobre a microcirculação. No presente estudo foram analisados os efeitos produzidos pela administração de solução salina hipertônica 7,5% sobre a hemodinâmica do tumor através de estudos de imagem funcional e posteriormente, foi avaliado o seu potencial de otimizar a entrega de moléculas no tumor. A velocidade do sangue nos vasos tumorais estimada por Ultrassom Color Doppler foi aumentada após a injeção da HSS em comparação ao controle PBS em tumores de melanoma (B16F10 (p=0,019), SK-MEL-147 (p =0,028)) e de mama (4T1 (p=0,015)). Este mesmo efeito não foi observado nas artérias segmentarias do rim (p=0,476). Ultrassonografia com contraste por microbolhas (CEUS) foi realizada em xenoenxertos de tumor de melanoma (B16F10), carcinoma de cólon (HCT-116) e mama (MDA-MB-231), e como controle foi realizada imagem no rim e no músculo nos animais portadores destes tipos tumorais (n=3 por grupo). Após a injeção da HSS, o volume relativo de sangue foi aumentado nos tumores B16F10 (p=0,022) e HCT-116 (P = 0,039), mas o mesmo não foi observado com o tumor MDA-MB-231 (p=0,186). Além disso, não houve alterações nos tecidos normais (rim p = 0,957; músculo p = 0,104). Todos os testes estatísticos foram bicaudais. Quando a HSS foi utilizada como veículo para entrega de moléculas de baixo peso molecular como cisplatina e doxorrubicina no tratamento de tumores B16F10 e 4T1 respectivamente, não houve aumento da eficácia terapêutica, avaliada através do crescimento tumoral e peso dos tumores. O efeito da HSS sobre a retenção de macromoléculas nos tumores SK-Mel- 147 e 4T1, avaliado através de imagem por epifluorescência do contraste ótico IR-783, não foi suficientemente notório para rejeitar a hipótese nula. Assim, a HSS induz um aumento transitório na velocidade do sangue e do volume sanguíneo, de maneira relativamente seletiva para os tumores avaliados, com exceção do MDA-MB-231. Portanto, esta pode ser uma estratégia útil para aumentar a entrega de moléculas e otimizar tanto o efeito terapêutico, quanto o diagnóstico por imagem / Intravenous administration of Hypertonic saline solution (HSS) induces systemic circulatory changes including blood pressure rising, effective circulating volume increase as well as local effects on microvasculature. We analyzed the effects produced by Hypertonic Saline 7,5% administration on tumor hemodynamics through functional imaging studies as well as whether it enhances molecular delivery in tumor tissue when used as a vehicle. Blood velocity assessed by Color Doppler Ultrasound was increased after HSS injection compared to PBS in the following tumors: B16F10 (p=0,019), SKMEL- 147 (p=0,028) and 4T1 (p=0,015). No statistical difference was observed on the segmental kidney arteries (p=0,476). Dynamic Contrast enhanced ultrasound (CEUS) was done in B16F10, HCT-116 and MDA-MB-231 tumor xenografts, kidney and muscle tissues (n=3 per group). After HSS injection, relative blood volume was increased in B16F10 (p=0,022) and HCT-116 (p=0,039) but not on MDA-MB-231 (p=0,186). Changes on normal tissues were not statistically different (kidney p=0,957; muscle p=0,104). All statistical tests were two-sided. Administration of HSS as a vehicle for low molecular weight molecules cisplatin and doxorubicin in the treatment of B16F10 and 4T1 tumors respectively had no significant improvement of therapeutic efficacy, estimated by tumor growth and tumor weight measurements. Effect of HSS over retention of macromolecules in tumors SK-Mel-147 and 4T1, evaluated by epifluorescence imaging of the optical contrast IR- 783 was not large enough to reject the null hypothesis. HSS induces a transient increase in velocity of the blood as well as the blood volume that is relatively selective for the evaluated tumors with exception of MDA-MB-231. Data suggest that HSS administration might be a useful strategy to increase the delivery of molecules and optimize both therapy and diagnostic imaging
14

Avaliação da administração intravenosa de solução salina hipertônica 7,5% como estratégia para melhorar a perfusão do tumor e a entrega de moléculas em modelos tumorais em camundongos / Evaluation of hypertonic saline solution 7,5% intravenous administration as a potential strategy to enhance tumor perfusion as well as molecular delivery in mice tumor models

Angelica Maria Patiño Gonzalez 20 December 2016 (has links)
A administração intravenosa de solução salina hipertônica (HSS) induz alterações sistêmicas circulatórias como o aumento da pressão arterial e do volume circulante efetivo, além de ter efeitos locais sobre a microcirculação. No presente estudo foram analisados os efeitos produzidos pela administração de solução salina hipertônica 7,5% sobre a hemodinâmica do tumor através de estudos de imagem funcional e posteriormente, foi avaliado o seu potencial de otimizar a entrega de moléculas no tumor. A velocidade do sangue nos vasos tumorais estimada por Ultrassom Color Doppler foi aumentada após a injeção da HSS em comparação ao controle PBS em tumores de melanoma (B16F10 (p=0,019), SK-MEL-147 (p =0,028)) e de mama (4T1 (p=0,015)). Este mesmo efeito não foi observado nas artérias segmentarias do rim (p=0,476). Ultrassonografia com contraste por microbolhas (CEUS) foi realizada em xenoenxertos de tumor de melanoma (B16F10), carcinoma de cólon (HCT-116) e mama (MDA-MB-231), e como controle foi realizada imagem no rim e no músculo nos animais portadores destes tipos tumorais (n=3 por grupo). Após a injeção da HSS, o volume relativo de sangue foi aumentado nos tumores B16F10 (p=0,022) e HCT-116 (P = 0,039), mas o mesmo não foi observado com o tumor MDA-MB-231 (p=0,186). Além disso, não houve alterações nos tecidos normais (rim p = 0,957; músculo p = 0,104). Todos os testes estatísticos foram bicaudais. Quando a HSS foi utilizada como veículo para entrega de moléculas de baixo peso molecular como cisplatina e doxorrubicina no tratamento de tumores B16F10 e 4T1 respectivamente, não houve aumento da eficácia terapêutica, avaliada através do crescimento tumoral e peso dos tumores. O efeito da HSS sobre a retenção de macromoléculas nos tumores SK-Mel- 147 e 4T1, avaliado através de imagem por epifluorescência do contraste ótico IR-783, não foi suficientemente notório para rejeitar a hipótese nula. Assim, a HSS induz um aumento transitório na velocidade do sangue e do volume sanguíneo, de maneira relativamente seletiva para os tumores avaliados, com exceção do MDA-MB-231. Portanto, esta pode ser uma estratégia útil para aumentar a entrega de moléculas e otimizar tanto o efeito terapêutico, quanto o diagnóstico por imagem / Intravenous administration of Hypertonic saline solution (HSS) induces systemic circulatory changes including blood pressure rising, effective circulating volume increase as well as local effects on microvasculature. We analyzed the effects produced by Hypertonic Saline 7,5% administration on tumor hemodynamics through functional imaging studies as well as whether it enhances molecular delivery in tumor tissue when used as a vehicle. Blood velocity assessed by Color Doppler Ultrasound was increased after HSS injection compared to PBS in the following tumors: B16F10 (p=0,019), SKMEL- 147 (p=0,028) and 4T1 (p=0,015). No statistical difference was observed on the segmental kidney arteries (p=0,476). Dynamic Contrast enhanced ultrasound (CEUS) was done in B16F10, HCT-116 and MDA-MB-231 tumor xenografts, kidney and muscle tissues (n=3 per group). After HSS injection, relative blood volume was increased in B16F10 (p=0,022) and HCT-116 (p=0,039) but not on MDA-MB-231 (p=0,186). Changes on normal tissues were not statistically different (kidney p=0,957; muscle p=0,104). All statistical tests were two-sided. Administration of HSS as a vehicle for low molecular weight molecules cisplatin and doxorubicin in the treatment of B16F10 and 4T1 tumors respectively had no significant improvement of therapeutic efficacy, estimated by tumor growth and tumor weight measurements. Effect of HSS over retention of macromolecules in tumors SK-Mel-147 and 4T1, evaluated by epifluorescence imaging of the optical contrast IR- 783 was not large enough to reject the null hypothesis. HSS induces a transient increase in velocity of the blood as well as the blood volume that is relatively selective for the evaluated tumors with exception of MDA-MB-231. Data suggest that HSS administration might be a useful strategy to increase the delivery of molecules and optimize both therapy and diagnostic imaging

Page generated in 0.0423 seconds