• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 133
  • 5
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 144
  • 144
  • 115
  • 20
  • 19
  • 17
  • 16
  • 16
  • 15
  • 15
  • 14
  • 13
  • 13
  • 13
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Análise da interface de adaptação de diferentes materias obturadores resinosos / Analysis of adaptation interface from different resin filling materials

Marcelo de Morais Vitoriano 25 June 2013 (has links)
Neste trabalho foi avaliado microscopicamente a interface de adaptação entre diferentes cimentos obturadores resinosos e dentina no interior do canal radicular de pré-molares humanos, identificando microscopicamente o nível de adaptação. Foram selecionadas 60 raízes de dentes uniradiculados, raízes retilíneas, com anatomia circular ou ovalada, ápices completos, obtidos por meio de doação feita por Cirurgião Dentistas e, consentidos seu emprego em pesquisas pelo paciente. Posteriormente as raízes foram divididas randomicamente em três grupos de acordo com o sistema de obturação empregado: Grupo 1 Guta-percha + cimento AHPlus; Grupo 2 Real Seal; Grupo 3 Sistema obturador smart-seal. Em seguida cada espécime recebeu cortes transversais em diferentes níveis, com 2mm de espessura, com disco diamantado, em máquina de corte de tecido duro (Isomet®) sob abundante irrigação. Após a realização dos cortes, as fatias a 2mm, 4mm, 6mm e 8mm foram analisadas em esteriomicroscópio, observando-se a área de adaptação cimento-dentina e em microscópio confocal para analisar a penetração do cimento em túbulos dentinários e a presença de fendas. As imagens obtidas foram analisadas pelo software de medida de área Image J®, em que as imagens foram devidamente calibradas. Os resultados apontaram uma superioridade do sistema Smart-seal na área de cimento no corte de 6mm (p<0,05), contudo uma inferioridade no que se tratou da penetração do cimento em túbulos dentinários nos cortes de 2mm, 6mm e 8mm (p<0,05). Em relação as fendas o smart-seal apresentou uma menor quantidade de fendas (p<0,05) apenas na medida de 8mm. Concluiu-se que apesar de sofrer expansão na tomada de presa, e melhor adaptação nas paredes do canal o sistema Smart Seal não apresentou penetrabilidade tubular satisfatória. / This study evaluated microscopically the interface adaptation between sealer and dentin within the root canal, identifying the level of sealing provided by different resin filling materials. 60 single rooted teeth were selected, roots straight with circular or oval anatomy, complete apexes, obtained through donation made by Surgeon Dentists and consented to its use in research by the patient. Subsequently the roots were randomly divided into three groups according to the system obturation: group 1 - Gutta-percha + cement AHPlus, Group 2 - Epiphany + Resilon, Group 3 - Smart Seal obturation system. Then each specimen received a transverse cut with 2 mm thick, with a diamond disc, cutting machine for hard tissue (Isomet ®) under abundant irrigation. After the cuts, slices to 2mm, 4mm, 6mm and 8mm were analyzed by esteriomicroscopy, observing the adaptation area between dentin and sealer, confocal microscopy was utilized to examine the penetration of cement into the dentinal tubules and the presence of gaps. The images were analyzed by software measurement area Image J ®, where the images have been properly calibrated. The results showed a superiority of Smart-seal in the area of cement in cutting 6mm (p <0.05), however inferiority in the penetration of the sealer into the dentinal tubules in sections of 2mm, 6mm and 8mm (p <0.05). Regarding the cracks Smart Seal had a smaller amount of cracks (p <0.05) only the extent of 8mm. It was concluded that although the Smart Seal system presentes expansion and better fit into the dentin walls of the canal, the system showed no satisfactory tubular penetration.
42

Influência da agitação ultrassônica do cimento obturador na ação antimicrobiana intra-dentinária e no preenchimento de istmos em canais mesiais de molares inferiores / Influence of ultrasonic agitation of the sealer on the intratubular antimicrobial activity and on the filling quality of isthmuses in mesial roots of mandibular molars

Murilo Priori Alcalde 12 June 2015 (has links)
Avaliou-se presença de espaços vazios, presença de fendas na interface cimento/dentina, o perímetro de penetração do cimento obturador nos canais e nos istmos.e a ação antimicrobiana intra-dentinária do cimento endodôntico (AH Plus) quando submetido ou não a agitação ultrassônica no momento da obturação. Para a avaliação do preenchimento de istmos foram utilizadas 30 raízes mesiais de primeiros molares inferiores, as quais foram divididas em 2 grupos (n=15). A instrumentação foi realizada com o sistema reciprocante Reciproc (R25) e finalizado com instrumento rotatório Mtwo (35.04). Em seguida, o cimento AH Plus foi espatulado com Rodamina B e foi inserido nos canais com espiral de Lentulo no35; o cimento do grupo 1 foi submetido a agitação ultrassônica enquanto o do grupo 2 não foi agitado, sendo que todos os canais foram obturados por meio da técnica do cone único e armazenados em estufa a 37oC durante 7 dias. As raízes foram seccionadas transversalmente a 2, 4 e 6 mm do ápice radicular para análise em esteromicroscópio e microscopia confocal a laser. Para a avaliação da ação antimicrobiana foram utilizados 30 incisivos de bovinos, os quais foram seccionados em cilindros de 6 mm de espessura. Os canais tiveram seu diâmetro padronizado com uma lima tipo K no 80 e então contaminados com Enterococcus faecalis (ATCC 29212) por 4 dias. Após esse período os espécimes foram divididas em 3 grupos (n=30). No grupo 1 o cimento foi agitado com o ultrassom e obturados com a técnica de cone único; no grupo 2 o cimento não foi agitado e o grupo 3 foi o grupo controle. As raízes foram seccionadas longitudinalmente no sentido vestíbulopalatino e coradas com corante LIVE/DEAD para avaliar a viabilidade bacteriana em microscopia confocal a laser. Para análise da agitação ultrassônica do cimento obturador no preenchimento de canais e istmos, foi utilizado o teste não paramétrico de Mann-Whitney (p <0.05) e para a análise da ação antimicrobiana intradentinária, foi utilizado o teste não paramétrico Kruskal-Waliis e o Teste Dunn (p <0.05). Os resultados indicaram que a agitação ultrassônica do cimento AH Plus favoreceu o preenchimento de istmos e a penetração intratubular. A agitação ultrassônica do cimento AH Plus reduziu significantemente a viabilidade bacteriana. Conclui-se que a agitação ultrassônica do cimento AH Plus favoreceu maior penetração intratubular, menor presença de fendas, menos espaços vazios e maior ação antimicrobiana. / In this study it was assessed the presence voids, gaps in the sealer/dentin interface, the intratubular sealer penetration in canals and isthmuses and intratubular antimicrobial effect of the AH Plus sealer when ultrasonic activation was performed during obturation. 30 mesial roots of mandibular first molars were selected and divided into 2 groups (n=15). Root canal instrumentation was performed with the reciprocating system Reciproc (R25) and finished with the Mtwo (35.04) rotary instrument. Then the AH Plus sealer was mixed with Rhodamine B and was inserted into the root canals with a Lentulo spiral #35. In group 1 the ultrasonic activation of the sealer was performed while in group 2 was not activated. Then, the root canal filling was performed using the single cone technique. After 7 days of storage the roots were sectioned at 2, 4 and 6 mm from the apex and analyzed in the stereomicroscope and by confocal laser scanner microscopy. To the antimicrobial test 30 bovine incisors cut into cylinders with 6 mm in thickness were used. The root canals diameter was standardized with a K file # 80 and then contaminated with Enterococcus faecalis (ATCC 29212) for 4 days. After this period the samples were divided into 3 groups (n = 30). In group 1 the ultrasonic activation of the sealer was perfomed and filled with single cone technique; in group 2 the sealer was not ultrasonic activated and in group 3 the canals were not obturated (control group). The roots were sectioned in the buccal-palatal direction and stained with LIVE / DEAD stain to assess the bacterial viability by confocal laser microscopy. For analysis of ultrasonic activation of the sealer on the filling quality of the canals and isthmuses, a non-parametric Mann-Whitney test (p <0.05) was used. For the analysis of the intradentin antimicrobial action, a Kruskal-Waliis nonparametric and Dunn\'s test was used (p <0.05). The results showed that the ultrasonic agitation of the AH Plus sealer favored the isthmus filling and the intratubular penetration. Also, the ultrasonic activation of AH Plus sealer reduced bacterial viability. It was concluded that the ultrasonic agitation of the sealer favored higher intratubular penetration, lower presence of gaps and voids and higher antimicrobial activity.
43

Influencia da superficie de resinas de poli (metil metacrilato) na estrutura de biofilmes de Candida albicans / Characterisitics of Candida albicans bioflm developed on poly (methil methacrilate) resins surfaces

Silva, Wander José da, 1980- 13 August 2018 (has links)
Orientadores: Altair Antoninha Del Bel Cury, Renata Cunha Matheus Rodrigues Garcia / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T01:31:00Z (GMT). No. of bitstreams: 1 Silva_WanderJoseda_D.pdf: 1629717 bytes, checksum: f107da940294da2fae00b7cf2e873b2b (MD5) Previous issue date: 2009 / Resumo: Os biofilmes de Cândida albicans formados sobre a superfície de resina de poli (metil metacrilato) (PMMA) apresentam alta virulência em função da liberação de enzimas hidrolíticas e são responsáveis pela candidose oral, infecção fúngica mais comum em usuários de próteses dentais removíveis. A organização do biofilme em várias camadas celulares envoltos por matriz de polissacarídeos extracelulares leva estas camadas celulares a estado metabólicos diferenciados e, portanto o uso da técnica de redução XTT ( 2, 3-bis (2-methoxy-4-nitro-5-sulfophenyl)-5-[(phenylamino) carbonyl]-2H-tetrazolium hydroxide), cuja reação é dependente da atividade celular, pode ser questionada. Assim, objetivou-se no primeiro estudo que compõem este trabalho, padronizar e aperfeiçoar esta técnica através da suplementação de glicose. Para isso, biofilmes de Cândida albicans ATCC 90028 com tempos de crescimento de 24, 48 e 72 h foram avaliados. Para estabelecer o melhor tempo de incubação do XTT, este foi mantido a temperatura de 37 °C, em tempos de 90, 180 e 270 minutos. A fórmula padrão do teste XTT (controle) foi modificada com a adição de 50, 100 e 200 mM de glicose para os grupos experimentais. Os melhores resultados para a incubação foram observados com tempo de 180 minutos e para a suplementação de glicose à concentração de 200 mM (p<0,001). Uma vez determinada a melhor condição de leitura da bioatividade dos biofilmes, foi idealizado o segundo estudo, que objetivou a mensuraçâo da bioatividade e a análise morfológica de biofilmes de Cândida albicans desenvolvidos sobre a superfície de PMMA. Duas resinas a base de PMMA (banho de água e microondas) foram utilizadas como substrato para o desenvolvimento de biofilmes de duas cepas de Cândida albicans (ATCC 90028 e SC5314). A atividade metabólica destes biofilmes foi mensurada com a técnica modificada de redução mitocondrial do XTT. A análise da morfologia da fase de adesão e dos biofilmes de 24, 48 e 72 horas foi avaliada com o auxilio do microscópio de varredura confocal a laser e o microscópio eletrônico de transmissão A combinação das análises da morfologia com a mensuraçâo da bioatividade, permitiu verificar o desenvolvimento do biofilme, desde a fase de adesão, com alta atividade metabólica, evoluindo para a constituição de uma comunidade microbiana de alta complexidade estrutural com a presença de matriz de polissacarídeos extracelulares, através da qual os nutrientes se difundem, porém dotados de pouca atividade metabólica. O método de ativação das resinas não interferiu na bioatividade do biofílme e com a morfologia do biofllme formado para a cepa de Candida albicans SC 5314. Com base nestes estudos concluiu-se que a incubação de 180 minutos utilizando a suplementação de 200 mM de glicose apresenta resultados de atividade metabólica celular com a menor variação para o estudo de biofilmes de Candida albicans e que a morfologia do biofílme de ambas as espécies foi fator fundamental para as diferenças na estrutura do biofílme / Abstract: Candida albicans biofilms, developed on poly (methyl methacrylate) (PMMA) resin surfaces show high virulence index due to hydrolytic enzyme secretion and are responsible for oral candidosis in removable denture wearer. Since biofilms are surrounded by an extracellular polysaccharides matrix, the nutrients diffusion across the cell layers is difficulted, occasioning cell with different metabolic states. Thus, considering that the XTT reduction assay is dependent of cellular activity, its use for evaluating mature biofilms may lead to inaccuracies since biofilm bottom cells layers tends to be relatively quiescent at later stages of biofilm formation. The aim of the first study was the improvement of the XTT reduction assay by using glucose supplements in the standard XTT formulation. Candida albicans ATCC 90028 was used to form 24, 48 and 72 hours biofilm. The oxidative activity at 90, 180 and 270 minutes of incubation was evaluated. The standard XTT composition was modified by the addition of 50, 100 and 200 mM of glucose. The control comprised XTT formulation without glucose supplements. Biofilm growth yield after 180 min incubation, when evaluated with the 200 mM glucose supplemented XTT produced the most consistent readings on repetitive testing (pO.001), After the results of the determination of the oxidative activity assay using XTT supplemented by 200 mM glucose second study was conducted in which it was evaluated the characteristics of biofilm development of Candida albicans on two different poly (methyl methacrilate) resins (PMMA). Thus, two different Candida albicans strain (ATCC 90028 and SC5314) were allowed to develop its biofilm in two PMMA surfaces with different polymerization method: waterbath (WB) and microwave (MW). Different time points (adhesion, 24, 48 and 72 hours) were compared. Surface roughness (SR) and surface free energy (SFE) of PMMA specimens were previously measured. Oxidative activity was measured by XTT. Confocal images were used to measure bio-volume, thickness, biofilm roughness, diffusion and the of live/dead cells proportion in the different biofilm development stages. Cell counts were used to estimate the number of cells, and a combination of these techniques allowed to describe the Candida albicans biofilms development, starting from a small amount of cells with high oxidative activity, reaching to microbial community of complexity structural prosperities, with the presence of a matrix of polysaccharide, however with low oxidative activity. WB and MW showed no difference regards SR. and SFE means (p>0,05) and oxidative activity showed different results for each specie (p<0.001). Based on both studies, it can be conclude that 180 min incubation with the 200 mM glucose supplemented XTT generates more accuracy in oxidative activity results and also that the different polymerization method of PMMA are not able to interfere with biofilm development and main differences detected were related to the intrinsic characteristic of each Candida strain and biofilm development time / Doutorado / Protese Dental / Doutor em Clínica Odontológica
44

Avaliação dos efeitos da irradiação do substrato dentinario com laser Er : YAG nos procedimentos restauradores adesivos : analise da permeabilidade, das propriedades fisicas e observação microscopica / Evaluation of Er : YAG laser irradiation on dentin bonding restorative procedures : analysis of permeability, physical properties and microscopic observation

Oliveira, Marcelo Tavares de 03 September 2009 (has links)
Orientador: Marcelo Giannini / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T10:19:14Z (GMT). No. of bitstreams: 1 Oliveira_MarceloTavaresde_D.pdf: 15233943 bytes, checksum: f6125d2132f3fd48d81be1d3cda778aa (MD5) Previous issue date: 2009 / Resumo: O uso de técnicas alternativas para preparo cavitário vem ganhando grande importância na Odontologia moderna. Entre estas tecnologias, o laser tem sido alvo de inúmeros estudos e para a realização de preparos cavitários o laser de Er:YAG é um dos mais indicados. Os objetivos deste estudo foram avaliar os efeitos de diferentes parâmetros de irradiação do substrato dentinário com laser de Er:YAG nos procedimentos restauradores adesivos e suas conseqüências sobre o substrato e sobre a união resina-dentina. Os testes foram realizados em superfícies dentinárias planificadas de terceiros molares humanos hígidos unidos a três diferentes sistemas adesivos (Single Bond 2 - 3M ESPE, Clearfil Protect Bond - Kuraray Medical Inc. e Clearfil Tri-S Bond - Kuraray Medical Inc.). Estas avaliações compreenderam o estudo da permeabilidade dentinária, da resistência de união, da longevidade e qualidade da união, além da análise da ultra-estrutura da interface de união através de microscopia eletrônica de transmissão e microscopia de varredura confocal laser. Os dados de permeabilidade e resistência de união foram analisados e submetidos à análise estatística com ANOVA 1-critério e ANOVA 3-critérios, respectivamente; ao encontrar diferenças significativas, o teste de Tukey foi utilizado. O nível de significância foi fixado em 5%. Os resultados mostraram ocorrer uma redução significativa na permeabilidade dentinária e que o parâmetro de 120mJ/4Hz foi o que promoveu a maior redução. Quanto à resistência de união, este estudo demonstrou que inicialmente, a irradiação com laser de Er:YAG reduz os valores de resistência de união, no entanto após 6 meses os valores são semelhantes tanto para o grupo controle, quanto para os grupos que foram irradiados. Além disso, pôde ser observado, que os sistemas autocondicionantes foram menos susceptíveis aos efeitos da irradiação do substrato, apresentando um comportamento mais uniforme. O sistema autocondicionante de dois passos também se mostrou mais estável ao longo do tempo. As imagens em microscopia eletrônica de transmissão e microscopia de varredura confocal laser, mostraram a formação de camada híbrida para todos os adesivos estudados com diferentes espessuras, quando aplicados sobre a dentina abrasionada. Não foi possível identificar camada híbrida uniforme e bem definida quando os sistemas foram aplicados em dentina irradiada com laser de Er:YAG, independentemente do parâmetro utilizado. Diante disso, os resultados sugerem que a irradiação da dentina com laser de Er:YAG reduz a permeabilidade dentinária, podendo influenciar na união dos adesivos à dentina nos períodos iniciais, entretanto após 6 meses os grupos irradiados foram iguais ao grupo controle. O exame ao microscópio revelou que a formação da camada híbrida é irregular e não-uniforme quando a dentina foi irradiada. / Abstract: The use of alternative techniques for cavity preparation is more common nowadays. Among these technologies, laser is the target of a great number of studies. The objectives of this study were to evaluate the effects of different parameters of dentin irradiation with Er:YAG laser on the adhesive procedures and their consequences over the substrate and resin dentin interface. Procedures were performed over flat dentin surfaces of human third molars bonded to three different adhesive systems ((Single Bond 2 - 3M ESPE, Clearfil Protect Bond - Kuraray Medical Inc. e Clearfil Tri-S Bond - Kuraray Medical Inc.). The evaluation tests were: dentin permeability, microtensile bond strengths, durability and the analysis of the ultra-structure using transmission electron microscope (TEM) and confocal laser scanning microscope (CSLM). Dentin permeability data and microtensile bond strength data were analyzed with one-way ANOVA and three-way ANOVA, respectively. Tukey test was used to point out differences among the tested groups. The significance level was fixed at 5%. Results showed a significative reduction on the dentin permeability and the 120mJ/4Hz parameter promoted the greatest reduction. For the microtensile bond strength test, this study showed that the irradiation with Er:YAG laser reduce the bond strength values at the baseline. After six months all groups became similar. Furthermore, self-etching systems were less affected by the Er:YAG laser irradiation. The two-step self-etching system seemed the more stable over time. TEM and CLSM images showed the hybrid-layer formation for all adhesive tested. The hybrid-layers had different thicknesses when the adhesive systems were bonded to abraded dentin. The observation of a uniform and well defined hybrid-layer was not possible when the adhesive systems were bonded to laser irradiated dentin, regardless of the used parameter. According to the data presented, dentin irradiation with Er:YAG laser reduce the permeability of the substrate, interfering on the bonding strength to dentin at the baseline, however, after six months laser irradiated groups were similar to control groups. Microscope analysis revealed that hybrid layer formation was irregular and non-uniform when dentin was laser irradiated. / Doutorado / Doutor em Materiais Dentários
45

Estratégias para adição de rodamina B em sistemas adesivos / Strategies for adding rhodamine B to bonding agents

Odair Bim Junior 01 April 2013 (has links)
A rodamina B e outros marcadores fluorescentes vêm sendo empregados na avaliação morfológica da interface de adesão com o auxílio de microscopia confocal de varredura a laser. Acrescentando-se rodamina B a sistemas adesivos, é possível observar as características de espessura da camada de adesivo, micromorfologia da camada híbrida, extensão e quantidade de tags, bem como diagnosticar defeitos ou alterações na interface de adesão. A literatura revela, entretanto, uma falta de precedentes sobre as quantidades de marcadores nos componentes resinosos. Além disso, ainda não se avaliou o efeito da concentração de rodamina B sobre a qualidade da análise da interface de adesão, bem como sobre o comportamento fotofísico dos marcadores nos sistemas adesivos. Este estudo foi realizado com o propósito de sistematizar um método de adição de rodamina B a sistemas adesivos, incluindo-se estratégias para a determinação de concentrações mínimas de rodamina nos componentes resinosos, porém, ainda viáveis para a realização da análise morfológica da interface de adesão através de microscopia confocal de varredura a laser. Para tal, os sistemas adesivos não simplificados e considerados padrão-ouro em suas categorias Adper&#x2122; Scotchbond&#x2122; Multi-Purpose (convencional de três passos) e Clearfil&#x2122; SE Bond (auto-condicionante de dois passos) foram modificados com rodamina B em cinco diferentes concentrações: C1 (0,5 mg/mL), C2 (0,10 mg/mL), C3 (0,02 mg/mL), C4 (0,004 mg/mL) e C5 (0,0008mg/mL) e o comportamento fluorescente da rodamina nos adesivos foi avaliado tanto no âmbito espectroscópico (espectroscopia de fotoluminescência), como no âmbito microscópico (microscopia confocal de varredura a laser). Para a modificação dos adesivos, utilizou-se uma técnica precisa de proporcionamento na qual o marcador fluorescente foi incorporado às resinas fluidas a partir de soluções de rodamina B em etanol. Os espectros de fluorescência mostraram diferenças nos máximos das bandas de emissão e de excitação, de acordo com as concentrações de rodamina B em cada material dispersante. A análise microscópica dos espécimes em dentina confirmou que é possível utilizar sistemas adesivos contendo rodamina B em concentrações muitas vezes menores do que as mencionadas na literatura. Ambos os sistemas avaliados puderam ser visualizados, microscopicamente, quando marcados com rodamina B nas três concentrações pré-selecionadas para a avaliação da interface de adesão: C2 (0,10 mg/mL), C3 (0,02 mg/mL) e C4 (0,004 mg/mL), sendo que C3 forneceu os melhores resultados em relação ao contraste e à saturação nas fotomicrografias. Concluiu-se que o comportamento fotofísico da rodamina B é influenciado tanto pela concentração, como pelo sistema adesivo no qual o marcador está dissolvido. A concentração de rodamina B também interfere na qualidade da análise morfológica da interface de adesão, sendo que o excesso do marcador pode dificultar a distinção de detalhes micromorfológicos. / Rhodamine B and other fluorescent markers have been used for the assessment of the bonding interface via confocal laser scanning microscopy. By adding rhodamine into adhesive systems, it is possible to study morphological characteristics of the hybrid layer, the extent and amount of resin tags and the adhesive layer thickness, as well as detecting potential defects or alterations at bonding interface. Meantime the literature reveals lack of standards among the quantities of fluorescent markers in resin-based polymers. The effects of rhodamine B concentration on the quality of the microscopic analysis, as well as on the photophysics of labeled adhesive systems were not assessed up to now. This study aimed to systematize methodologies for adding rhodamine B into adhesive systems, including suitable strategies for determining the minimum serviceable rhodamine concentrations to perform the morphological analysis of the bonding interface. Two non-simplified adhesive system considered gold standard categories Adper&#x2122; Scotchbond&#x2122; Multi-Purpose (3 steps conventional) and Clearfil&#x2122; SE Bond (2 steps self-etching) were modified with rhodamine B at five concentrations: C1 (0.5 mg/ml), C2 (0.10 mg/ml), C3 (0.02 mg/ml), C4 (0.004 mg/ml) and C5 (0.0008 mg/ml ) and the fluorescent behavior of the labeled resins was assessed both by photoluminescence spectroscopy and by confocal laser microscopy The preparation of the labeled resins was proceed by means of a precise proportioning technique in which the fluorescent marker was incorporated into the bonding agents from solutions of rhodamine B in ethanol. The fluorescence spectra showed differences in the intensity and wavelength fluorescence according to the rhodamine B concentration. Microscopic analysis of the dentin specimens confirmed adhesive systems can be modified with rhodamine B at far lower concentrations than those mentioned in the literature. Both evaluated systems were microscopically visualized while labeled with Rhodamine B at three pre-selected concentrations: C2 (0.10 mg/mL), C3 (0.02 mg/ml) and C4 (0.004 mg/ml), and C3 offered the best outcome with respect to contrast and saturation in photomicrographs. It was concluded that the photophysical behavior of rhodamine B depends on both the concentration and labeled adhesive system. The rhodamine B concentration also interferes with the quality of morphological analysis of the bonding interface, and the excess of the fluorescent marker may jeopardize the discrimination of morphological details.
46

Influência da medicação intracanal na penetração do cimento endodôntico e na microdureza dentinária / Influence of the intracanal medication in the penetration of root canal sealer and dentin microhardness

Abi-Rached, Giselle Priscilla Cruz, 1977- 06 September 2014 (has links)
Orientador: Brenda Paula Figueiredo de Almeida Gomes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-25T06:52:53Z (GMT). No. of bitstreams: 1 Abi-Rached_GisellePriscillaCruz_D.pdf: 2078031 bytes, checksum: d37b59779d6837d43861de393deca877 (MD5) Previous issue date: 2014 / Resumo: O objetivo deste estudo foi avaliar a influência da remoção da medicação intracanal (hidróxido de cálcio associado à clorexidina gel 2%) por meio das técnicas ultrassônica e manual de ativação do EDTA 17% na penetração do cimento endodôntico na obturação de canais radiculares. Foi objeto deste estudo também, a investigação da microdureza dentinária após o uso da associação clorexidina gel 2% e hidróxido de cálcio e do uso de EDTA 17%. A penetração do cimento durante a obturação de canais radiculares foi avaliado por microscopia confocal de varredura a laser (MCVL), após a remoção da medicação intracanal. Para isso, foram selecionados trinta dentes humanos unirradiculares com canais retos. A instrumentação dos canais foi realizada por meio de limas rotatórias MTwo. Os dentes foram divididos aleatoriamente em três grupos: I e II receberam a medicação intracanal acrescida de fluoresceína e III) grupo controle foi obturado imediatamente após o preparo químico-mecânico. Os dentes com medicação intracanal foram armazenados por quinze dias em 100% de humidade, a 37oC. A medicação foi então removida com EDTA 17%, sendo que no grupo I este foi agitado manualmente por cone de guta-percha e no grupo II foi ativado pelo ultrassom. Todos os canais radiculares (controle e grupos experimentais) foram obturados com o cimento Pulp Canal Sealer acrescido do corante Rodamina B. Secções transversais do terço médio de cada amostra foram visualizadas por meio de MCVL. O teste de Tukey evidenciou que a ativação com ultrassom propiciou maiores valores de penetração de cimento obturador Pulp Canal Sealer após a remoção da medicação intracanal (92,30 ± 9,69 %), sendo estatisticamente mais efetiva na remoção da medicação intracanal quando comparado com a ativação manual (43,61 ± 12,95) (p<0,05). Para a análise da microdureza dentinária, dez dentes unirradiculares foram seccionados transversalmente na junção amelo-cementária e tiveram suas coroas descartadas. As raízes foram fixadas em placas de resina acrílica e cortadas transversalmente a cada 1mm. Secções do terço médio foram divididas em 4 partes e os quadrantes foram incluídos em resina epóxica. Cada tratamento: I) Associação de hidróxido de cálcio e clorexidina gel 2%, II) EDTA 17%, III) água destilada; foram aplicados na superfície dentinária e a mensuração da microdureza Knoop foi realizada. O teste de Tukey evidenciou que o grupo da água destilada (controle) resultou nos maiores valores de Microdureza Knoop (81,50 ± 1,80), sendo estatisticamente diferente (p<0,05) dos demais. Os grupos do hidróxido de cálcio (54,65 ± 2,31) e EDTA 17% (54,99 ± 2,41) apresentaram os menores valores médios, sendo estatisticamente semelhantes entre si (p>0,05). Foi concluído que houve a maior penetração do cimento obturador quando a remoção da medicação intracanal foi realizada com a utilização do EDTA ativado pelo ultrassom e que o uso do EDTA 17% e da associação de hidróxido de cálcio com clorexidina gel 2% alteraram a microdureza dentinária / Abstract: The aim of this study was to evaluate the influence of removal of the medication (calcium hydroxide associated with chlorhexidine gel 2%) through ultrasonic techniques and manual activation of EDTA 17% penetration of the sealer in root canal filling. Object of this study was also to investigate the dentin microhardness after use of the combination of 2% chlorhexidine gel and calcium hydroxide and the use of 17% EDTA. The penetration of the sealer during the root canal filling was evaluated by confocal laser scanning microscopy (CLSM), after intracanal medicatication removal. For this, we selected thirty single-rooted human teeth with straight canals. The instrumentation of the channels is performed by rotating MTwo files. The teeth were randomly divided into three groups: group I and II received the intracanal medication plus fluorescein and III) control group was obturated immediately after chemo-mechanical preparation. Teeth with intracanal medications were stored for two weeks at 100% humidity at 37oC. The medication was then removed with 17% EDTA, and the group I was activated manually by gutta-percha cone and in group II was activated by ultrasound. All root canals (control and experimental groups) were filled with Pulp Canal Sealer sealer plus dye Rhodamine B. Cross sections of the middle third of each sample were visualized by CLSM. The Tukey test showed that activation with ultrasound led to higher penetration of sealer Pulp Canal Sealer after removal of the medication (92.30 ± 9.69%) and was statistically more effective in the removal of the medication compared with manual activation (43.61 ± 12.95) (p <0.05). For the analysis of dentin microhardness. Ten single-rooted teeth were sectioned at the cementoenamel junction and had their crowns discarded. The roots were fixed in acrylic resin plates and sanded every 1mm. Sections of the middle third were divided into 4 parts and quadrants were embedded in epoxy resin. Each treatment: i) Association of calcium hydroxide and 2% chlorhexidine gel, II) 17% EDTA, III) distilled water; were applied on the dentin surface and the measurement of microhardness was performed. The Tukey test showed that the group of distilled water (control) resulted in higher values of Knoop microhardness (81.50 ± 1.80) and was statistically different (p <0.05) than the other. Groups of calcium hydroxide (54.65 ± 2.31) and 17% EDTA (54.99 ± 2.41) had the lowest mean values were statistically similar (p> 0.05). It was concluded that there was a greater penetration of the sealer when removal of the medication was performed with the use of EDTA activated by ultrasound and the use of 17% EDTA and the association of calcium hydroxide with 2% chlorhexidine gel altered dentin microhardness / Doutorado / Endodontia / Doutora em Clínica Odontológica
47

Efeito da composição e aquecimento prévio de infiltrantes sobre propriedades físicas e penetração em lesões iniciais de cárie em esmalte / Effect of infiltrants composition and pre-heating on physical properties and penetration in initial enamel caries lesions

Gaglianone, Lívia Aguilera, 1985- 26 August 2018 (has links)
Orientador: Giselle Maria Marchi Baron / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-26T05:50:55Z (GMT). No. of bitstreams: 1 Gaglianone_LiviaAguilera_D.pdf: 3416784 bytes, checksum: 47ff2260453d6852e725b4b6356954ae (MD5) Previous issue date: 2014 / Resumo: O objetivo do presente estudo foi avaliar o efeito do pré-aquecimento e da composição de infiltrantes no grau de conversão (GC), nas propriedades físicas e profundidade de penetração em lesões cariosas de mancha branca em esmalte. Os grupos foram assim divididos, de acordo com a composição do material: [Produto comercial Icon®]; [INF 1 - 25% BisEMA, 75% TEGDMA]; [INF 2 - 25% BisEMA, 65% TEGDMA, 10% etanol]; [INF 3 - 25% BisEMA, 65% TEGDMA, 10% HEMA]; [INF 4 - 100 % TEGDMA]; [INF 5 - 90% TEGDMA, 10% etanol]; [INF 6 - 90% TEGDMA, 10% HEMA]; e cada uma dessas resinas foi testada em diferentes condições de temperatura (25°C e 55°C). Para avaliação do GC (n=3), mensurações antes e após fotoativação das amostras (LED Bluephase 5i ¿ Ivoclar Vivadent, 1000 mW/cm2, por 60 s) foram realizadas em espectrômetro de raios infravermelhos e o cálculo foi feito considerando a razão entre espectros não-polimerizados e polimerizados do material. As mesmas amostras de GC (n=3) foram utilizadas no teste de sorção (So) e solubilidade (SL), sendo que as amostras polimerizadas foram pesadas após dessecação inicial (m1), armazenadas em água destilada por 7 dias e pesadas para obtenção de m2, e após nova secagem, foram novamente pesadas até obtenção da massa final (m3). O módulo de elasticidade (ME) e resistência à flexão (RF) dos espécimes (n=10), em forma de barra (7 mm X 2 mm X 1 mm), foram obtidos com teste de 3 pontos em Máquina de Ensaio Universal (0,5 mm/min). O ângulo de contato entre os materiais não polimerizados e a superfície polida de um sólido foi obtido utilizando um goniômetro com uma câmera acoplada. A análise da profundidade de penetração dos materiais testados em lesões artificiais de mancha branca sub-superficiais foi realizada por meio de imagens obtidas por Microscopia Confocal de Varredura a Laser (MCVL), com impregnação de marcadores fluorescentes (rodamina e fluorosceína de sódio) aos materiais avaliados e fragmentos dentais cariados, respectivamente. Os dados foram submetidos à ANOVA 2-critérios e teste de Tukey (?=5%). O aumento da temperatura não influenciou ME e RF. Maior ME foi atribuído ao INF 3 enquanto que os menores valores foram obtidos por INF 5. A 25oC, nenhuma resina testada alcançou 50% de conversão, mas, todos os valores de GC foram superiores a 60% quando pré-aquecidos. Houve redução significante de So a 55oC. Avaliando SL, INF 5 (TEGDMA + etanol) mostrou altos valores, enquanto Icon aquecido foi associado a baixa solubilidade. A maioria dos grupos apresentou aumento do ângulo de contato, a 55oC. Em contrapartida, grupos contendo HEMA mostraram diminuição do ângulo após aquecimento do material. Não houve diferença entre as temperaturas para profundidade de penetração. O material à base de TEGDMA (INF 4) apresentou profundidade de penetração mais homogênea, enquanto que o Icon foi associado a infiltração mais superficial. Pode-se concluir que o aumento prévio da temperatura do infiltrante foi capaz de afetar algumas das propriedades avaliadas (principalmente, GC e So/SL), e que essa abordagem foi mais vantajosa para materiais de composição mais hidrófoba / Abstract: The aim of the present study was to evaluate the composition of infiltrant blends and the pre-heat effect on degree of conversion (DC), physical properties and penetration depth into enamel white spot caries lesions. Groups were set up as follows: [commercially available product Icon®]; [INF 1 - 25% BisEMA, 75% TEGDMA]; [INF 2 - 25% BisEMA, 65% TEGDMA, 10% etanol]; [INF 3 - 25% BisEMA, 65% TEGDMA, 10% HEMA]; [INF 4 - 100 % TEGDMA; INF 5 - 90% TEGDMA, 10% etanol]; [INF 6 - 90% TEGDMA, 10% HEMA]; and each one of these resins was tested under different temperature conditions (25°C and 55°C). DC (n=3) was measured using infrared spectroscopy and calculated by comparing the spectra from samples before and after light activation (LED Bluephase 5i ¿ Ivoclar Vivadent, 1000 mW/cm2, for 60 s). For water sorption (WS) and solubility (SL) test, the same DC samples (n=3) were subjected to water degradation method. After desiccation, polymerized samples were initially weighed (m1), stored in distilled water for 7 days (m2), and, after further drying, a constant mass (m3) were obtained. For the mechanical test (elastic modulus - E / flexural strength - FS), ten bar shaped specimens (7 mm X 2 mm X 1 mm) were prepared to be tested using the three-point flexural test, at a crosshead speed of 0.5 mm/min. Unpolymerized infiltrants contact angle in relation to a polished solid surface were obtained using a goniometer. Penetration depth into artificial enamel white spot caries lesions was evaluated using dual fluorescence confocal microscopy (rodhamine and sodium fluoroscein). All data were subjected to 2-way ANOVA and Tukey¿s test, and the significance level was set at a = 0.05. Pre-heated condition presented no influence in E and FS. Higher E values were attributed to INF3 while low ones were obtained by INF 5. At 25oC, DC did not reach 50% of conversion for all resins tested, but, with the pre-heating, all DC increased to more than 60%. There was significant WS reduction at 55oC. Analysing SL, INF 5 (TEGDMA + etanol) presented high values, and low means were found for heated Icon. Most of the groups were associated to increased contact angle, at 55oC. In contrast, the presence of HEMA led to a decrease of this parameter after material pre-heating. Finally, there was no statistical difference between temperatures for penetration depth. TEGDMA-based material (INF 4) presented more homogeneous penetration whereas Icon was associated to shallow infiltration. It can be concluded that the increase of infiltrant¿s temperature, prior polymerization step, was able to affect some of the evaluated properties (mainly DC and WS/SL). Overall, this approach was mostly beneficial for blends containing hydrophobic monomers / Doutorado / Dentística / Doutora em Clínica Odontológica
48

Development of Candida albicans biofilms in the presence of fluconazole = effects on extracellular matrix = Desenvolvimento de biofilmes de Candida albicans na presença de fluconazol : efeitos na matriz extracelular / Desenvolvimento de biofilmes de Candida albicans na presença de fluconazol : efeitos na matriz extracelular

Gonçalves, Letícia Machado, 1987- 27 September 2013 (has links)
Orientador: Wander José da Silva / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T13:26:50Z (GMT). No. of bitstreams: 1 Goncalves_LeticiaMachado_D.pdf: 3139804 bytes, checksum: 4f3ad00e23ae5ec0336267a151dbe2e0 (MD5) Previous issue date: 2012 / Resumo: O fluconazol (FLZ) é um antifúngico amplamente utilizado no tratamento da candidose associada ao uso de prótese dental. No entanto, o sucesso desta terapia pode ser dificultado pela presença da matriz extracelular dos biofilmes de Candida albicans. Estudos já foram conduzidos avaliando o efeito do FLZ em biofilmes de C. albicans, no entanto, estudos que simulem uma condição na qual os biofilmes são desenvolvidos na presença do FLZ são escassos. Ainda, na tentativa de avaliar a organização tridimensional destes biofilmes, várias técnicas de microscopia já foram descritas, apesar de pouca atenção ser dada na análise da matriz extracelular. Frente ao exposto, o objetivo deste trabalho foi avaliar a matriz extracelular de biofilmes de C. albicans na presença de concentração salivar de FLZ. Dois estudos foram conduzidos e, em ambos, discos (10 mm x 2 mm) de resina acrílica à base de poli (metil metacrilato) foram confeccionados e cobertos com uma película de saliva sobre a qual biofilmes de C. albicans foram desenvolvidos. O primeiro estudo foi conduzido com o objetivo de definir uma metodologia para análise da matriz extracelular. Biofilmes de C. albicans ATCC 90028 foram desenvolvidos em meio de cultura sem suplementação (controle) ou suplementado com glicose ou sacarose, por 72 horas. Durante o desenvolvimento dos biofilmes foi adicionado o corante Concanavalina A (ConA) para a marcação da matriz extracelular. Após o desenvolvimento, os biofilmes foram corados com SYTO 9 para a marcação das células. As imagens obtidas por microscopia confocal foram analisadas pelo software COMSTAT. Para confirmação dos resultados, os biofilmes foram coletados e analisados bioquimicamente para determinação da composição da matriz de polissacarídeos pelo método fenol-sulfúrico. Os dados foram analisados por ANOVA seguido do teste de Tukey com nível de significância de 5%. Para o segundo estudo, biofilmes de C. albicans (ATCC 90028) e de dois isolados clínicos (P01 e P34) foram desenvolvidos em meio de cultura contendo FLZ na concentração biodisponível na saliva (2,56 ?g/mL), durante 48h. O grupo controle foi desenvolvido sem a presença de fluconazol. O número de células viáveis foi quantificado por diluição seriada, e a matriz extracelular analisada bioquimicamente, além da avaliação por microscopia confocal. Os dados foram analisados pelo teste t de Student com nível de significância de 5%. No primeiro estudo, observou-se que o uso de ConA permitiu uma marcação eficaz da matriz extracelular, confirmada pela análise bioquímica (p < 0,05). No segundo estudo, houve uma redução de 80% no número de células viáveis dos biofilmes desenvolvidos na presença de FLZ (p < 0,001). Considerando-se a proporção de polissacarídeos produzidos pelo número de células viáveis, observou-se que nos grupos experimentais, C. albicans foi capaz de produzir mais matriz extracelular do que os grupos controle (p < 0,05). Este resultado foi confirmado pelas imagens obtidas por microscopia confocal. Conclui-se que a microscopia confocal é uma ferramenta efetiva na análise da matriz extracelular de biofilmes de C. albicans, e que os biofilmes de C. albicans desenvolvidos na presença de FLZ apresentaram maior produção de matriz extracelular / Abstract: Fluconazole (FLZ) is a commonly used antifungal agent to treat patients with Candida-associated denture stomatitis. However, the success of this therapy may be compromised by the presence of extracellular matrix of C. albicans biofilms. Although studies have been conducting evaluating the effect of FLZ on C. albicans biofilms, studies that simulate the condition in which biofilms were allowed to grow in the presence of FLZ are limited. Additionally, in order to evaluate the three-dimensional organization of these biofilms, several microscopic techniques have been described, although little attempt has been paid to assess the extracellular matrix. The objective of this study was to investigate the extracellular matrix of C. albicans biofilms in the presence of salivary concentration of FLZ. For this, two studies were conducted. For both studies, discs (10 mm x 2 mm) were fabricated using poly (methyl methacrylate). Salivary pellicle was formed on disc surface and C. albicans biofilms were developed. In the first study a methodology for analyzing the extracellular matrix was defined. C. albicans ATCC 90028 biofilms were developed in culture media without (control) or with supplementation by glucose or sucrose for 72 hours. During development, biofilms were stained with Concanavalin A (ConA) in order to label the extracellular matrix. After, cells were also labeled with SYTO-9. Images obtained by confocal microscopy were analyzed by COMSTAT software. In order to confirm the results, biofilms were subjected by the biochemical phenol-sulfuric method. Data were analyzed by ANOVA followed by Tukey's test at a significance level set at 5%. For the second study, biofilms of an ATCC 90028 and two clinical isolates (, P01 and P34) were developed for 48 hours. FLZ at 2.56 ?g/mL, concentration bioavailable in saliva, was added to culture media of experimental groups. Biofilms were investigated for the number of viable cells by serial dilution and extracellular matrix production was analyzed by phenol-sulfuric method and confocal microscopy. Data were analyzed by Student's t-test, with significance level set at 5%. In the first study, the use of ConA provided an effective labeling of extracellular matrix, which was confirmed by phenol-sulfuric method (p < 0.05). In the second study, a reduction of 80% was observed in the number of viable cells for C. albicans biofilms developed in the presence of FLZ (p < 0.001). Considering the proportion of polysaccharides produced by the number of viable cells, it was observed that in the experimental groups, C. albicans was able to produce more extracellular matrix than the control groups (p < 0.05). This result was confirmed by confocal images. It was concluded that confocal microscopy is an effective tool to investigate the extracellular matrix of C. albicans biofilms; and C. albicans biofilms developed in the presence of FLZ present increased extracellular matrix production / Doutorado / Protese Dental / Doutora em Clínica Odontológica
49

Use of fluorescence in the performance evaluation of adhesive systems = Uso da fluorescência na avaliação do comportamento de sistemas adesivos / Uso da fluorescência na avaliação do comportamento de sistemas adesivos

Araújo, Cíntia Tereza Pimenta de, 1968- 21 August 2018 (has links)
Orientador: Luis Alexandre Maffei Sartinni Paulillo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T22:09:59Z (GMT). No. of bitstreams: 1 Araujo_CintiaTerezaPimentade_D.pdf: 9367664 bytes, checksum: 6c7161dae0f158a143f829e530249b20 (MD5) Previous issue date: 2013 / Resumo: A microscopia confocal de varredura a laser (MCVL) é um recurso de visualização microscópica que permite a análise de materiais ou estruturas com requisitos mínimos de preparação de amostras de modo não destrutivo. Assim, os objetivos deste estudo foram: avaliar a influência da incorporação do corante fluorescente Rodamina B (R) nas propriedades mecânicas resistência coesiva (RC), módulo de elasticidade (ME) e resistência à flexão (RF) de 2 sistemas adesivos, o autocondicionante Clearfil SE Bond e o convencional Scotchbond Multi-Purpose (estudo 1); validar o método modificado de microtração (?TBS), em que micro-amostras de secção transversal de 0,09 mm2 foram testadas e verificar a influência da R na resistência à união a dentina e integridade interfacial através de microscopia confocal (estudo 2). Para avaliar a influência do corante, 0,16 mg/ml de R foram incorporados aos adesivos constituindo assim dois grupos para cada adesivo: grupos dos adesivos corados e não corados totalizando 4 grupos experimentais. Para a análise da RC, E e RF, os corpos de prova foram confeccionados a partir de uma matriz de silicone por adição. Sobre a matriz, foram dispensados 10 ?L de adesivo variando de acordo com cada grupo de adesivos corados e não corados. RC (n= 10), E e RF (n= 5) foram avaliadas em máquina de ensaio universal a 0,5 mm/min, até a ruptura da amostra. Para visualização em microscopia confocal e análise da resistência à união os adesivos foram aplicados à superfície plana da dentina oclusal de 32 pré-molares humanos. Após a realização dos procedimentos adesivos, realizaram-se as restaurações (blocos de 16 mm2) com Charisma Opal (Kulzer - cor A3). Em seguida, para a realização do teste modificado de microtração, micro-amostras em forma de palito (secção transversal 0,09 mm2) foram confeccionadas. Previamente ao ensaio mecânico, foi realizada através de MVCL a análise micromorfológica das microamostras dos grupos de adesivos corados. Posteriormente a resistência à união foi mensurada através do ensaio modificado de microtração a velocidade de 0,5 mm/min em máquina de ensaio universal. Os dados de todos os testes avaliados foram submetidos à análise de variância dois fatores. Os resultados mostraram que o comportamento dos sistemas adesivos investigados não se modificou, independente da presença do corante, pois não foram observadas diferenças significativas nas propriedades mecânicas estudadas: resistência à união, resistência coesiva, resistência flexural, módulo de elasticidade, bem como a integridade interfacial. A preparação de micro-amostras não comprometeu os resultados do ensaio de resistência adesiva. De acordo com os resultados obtidos e análise dos parâmetros: coeficiente de variação, porcentagem de padrão de fratura e incidência de falhas prematuras, concluiu-se que o teste modificado de microtração foi considerado um método confiável para a avaliação da resistência à união de sistemas adesivos. A técnica de visualização microscópica confocal produziu informações detalhadas da interface adesiva e pode ser bem indicada para a avaliação da efetividade de união de sistemas adesivos. Desta forma, é possível associar ambas as metodologias obtendo-se uma avaliação mais realista e confiável dos materiais restauradores / Abstract: The confocal laser scanning microscopic (CLSM) is a tool of visualization that allows microscopic analysis of materials or structures labeled with fluorescent dyes with minimal requirements of specimen's preparation nondestructively. The aims of this study were: to evaluate the influence of incorporation of fluorescent dye Rhodamine B (R) in the properties mechanical: cohesive strength (CS), elastic modulus (E) and flexural strength (FS) of the selfetching Clearfil SE Bond and etch-and-rinse Scotchbond Multi-Purpose (Study 1); validating the modified microtensile method using micro-specimens cross section of 0.09 mm2 (?TBS) and evaluate the influence of R in bond strength in dentin and interfacial integrity by confocal microscopy (study 2). To evaluate the influence of the dye, 0.16 mg/ml of R were incorporated into adhesives thus forming two groups for each adhesive: groups of labeled adhesives and no-labeled totaling 4 experimental groups. For the analysis of CS, E and FS the specimens were made from a silicone matrix. About the matrix were 10 ?L dispensed adhesive varying according to each group of adhesives stained or not. CS (n = 10), E and FS (n = 5) were evaluated in a universal testing machine at 0.5 mm/min until failure of the specimen. For visualization in confocal microscopy and bond strength analysis (n = 8), the adhesives were applied to the occlusal dentine surface 32 of human premolars. After procedures adhesives, composite crowns approximately (16 mm2) were built up with Charisma Opal (Kulzer - color A3). Then for testing modified microtensile, micro-specimens beam-shaped were prepared. Prior to mechanical testing micromorphological analysis of micro-sticks of the groups of labeled adhesives was performed using CLSM. Subsequently bond strength was measured using the modified microtensile test in a universal testing machine speed of 0.5 mm/min. The results showed that the behavior of the adhesive systems investigated did not change regardless of the presence of the dye, as there were no significant differences in mechanical properties studied: bond strength, tensile strength, flexural strength, modulus of elasticity, as well as interfacial integrity. The preparation of micro-specimens did not affect the results of the bond strength test. According to the analysis results and parameters: coefficient of variation percentage of fracture pattern and incidence of early failures, it is concluded that the modified microtensile test was considered a reliable method for evaluating the bond strength of adhesive systems. The confocal microscopic visualization technique yielded detailed information of the adhesive interface and can be well suited for evaluating the effectiveness of adhesive systems. Thus, it is possible to associate both methods give a more realistic and reliable adhesive restoration on the presence of fluorescent dye / Doutorado / Dentística / Doutora em Clínica Odontológica
50

Evaluation of surface restorative materials submitted to degradation by biofilm, in situ = Avaliação da superfície de materiais restauradores submetidos à degradação por biofilme, in situ / Avaliação da superfície de materiais restauradores submetidos à degradação por biofilme, in situ

Padovani, Gislaine Cristina, 1979- 21 August 2018 (has links)
Orientadores: Mário Alexandre Coelho Sinhoreti, Regina Maria Puppin Rontani / Tese (Doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T23:42:58Z (GMT). No. of bitstreams: 1 Padovani_GislaineCristina_D.pdf: 3925826 bytes, checksum: 08a5817db8d9559d4351de141cf3a5b5 (MD5) Previous issue date: 2013 / Resumo: Os objetivos desta tese composta por dois capítulos foram: Capítulo 1- avaliar as características estruturais e a viabilidade do biofilme, in situ, acumulado após 07 dias sobre diferentes materiais restauradores e Capítulo 2 - avaliar as características de superfície de diferentes materiais restauradores após 07 dias à biodegradação in situ. No capítulo 1 - quinze discos de cada material (IPS E.Max; Filtek Supreme; Vitremer; Ketac Molar Easymix; Amalgam GS-80) foram confeccionados em uma matriz metálica de 4,0mm X 1,5mm. O polimento foi realizado com o auxílio de discos Sof-Lex para os corpos-de-prova de Filtek Supreme, Vitremer e Ketac Molar Easymix; o Amalgam GS-80 foi polido com o kit de polimento para amálgama de prata e os corpos-de-prova de IPS E.Max foram jateados por óxido de alumínio, seguidos por ponta diamantada, taça de borracha e glazer. Para a realização da biodegradação in situ, foram selecionados quinze voluntários com idades entre 21-30 anos. Um dispositivo palatino, contendo 5 poços (um material restaurador por poço) foi confeccionado para cada voluntário. Após 07 dias de biodegradação imagens do biofilme utilizando o Microscópio de Varredura Confocal a Laser (CLSM) foram realizadas. A análise quantitativa foi realizada com o auxílio do software COMSTAT avaliando parâmetros como: área, biomassa, espessura média, espessura máxima e coeficiente de rugosidade. Na análise qualitativa, as imagens CLSM foram visualmente observadas e descritas como: viabilidade celular - predominância de verde e vermelho e arquitetura do biofilme - predominância e distribuição de espaços e canais no biofilme. Os dados foram analisados estatisticamente utilizando o teste de Kolmogorov-Smirnov e Kruskal-Wallis ao nível de 5% de significância. Os resultados demonstraram não haver diferença estatística entre os materiais avaliados e os parâmetros selecionados. Porém, Filtek Supreme e IPS E.Max apresentaram visualmente maior quantidade de células viáveis em comparação aos outros materiais restauradores. Assim, conclui-se que: na análise quantitativa não houve influência significativa do material restaurador sob as características morfológicas do biofilme. Entretanto, a análise qualitativa demonstrou aparentemente variações na viabilidade bacteriana frente aos diferentes materiais restauradores. No capítulo 2 - A metodologia empregada na confecção e preparo dos corpos-de-prova foi à mesma utilizada no capítulo 1, sendo os corpos-de-prova submetidos à leitura de dureza, rugosidade de superfície, análise de Microscopia Eletrônica de Varredura e análise de Energia Dispersiva de Raios-X antes e após a biodegradação. Os dados foram submetidos aos testes de Kolmogorov-Smirnov e Tukey-Kramer, nível de significância de 5%. Todos os materiais restauradores estéticos mostraram aumento significativo nos valores de rugosidade após biodegradação, confirmado pelas micrografias. Para a análise da dureza, Vitremer, Ketac Molar Easymix e Amalgam Gs-80 demonstraram aumento significativo nos valores após a biodegradação. A composição química inicial do Amálgama GS-80 e IPS E.Max não foi alterada pela ação do biofilme in situ, enquanto Filtek Supreme, Vitremer e Ketac Molar Easymix apresentaram alterações em seus espectros, com liberação de fluoreto para os materiais ionoméricos e adsorção de íons (Ca2+, Cl-) na superfície desses materiais. Pode-se concluir que os efeitos do biofilme sobre as propriedades de superfície são material-dependente / Abstract: The objectives of this Thesis, accomplished on two chapters, were: Chapter 1 - to evaluate the influence of different restorative materials on the morphology of biofilm, in situ, and Chapter 2 - to evaluate the influence of biofilm on the surface characteristics of different restoratives materials. Chapter 1- Fifteen discs of each material (IPS E.Max; Filtek Supreme; Vitremer; Ketac Molar Easymix; Amalgam GS-80) were prepared using a metallic mold of 4.0 mm X 1.5 mm. Polishing procedure was performed with sof-lex discs on composite resin, glass ionomer cement and cement-modified glass ionomer specimens; silver amalgam specimens were polished with a polishing kit for amalgam; ceramic specimens were polished with a aluminum oxide jet, followed by a diamond drill, rubber tip and glazer. To perform the in situ biodegradation, fifteen volunteers were selected (aged 21-30 years). A palatal device containing 5 wells (one restorative material per well) was prepared for each volunteer. After 07 days of biodegradation, a morphology analysis of the biofilm was performed using confocal laser scanning microscopy. The images generated by confocal microscopy were then converted into numerical data with the aid of the COMSTAT software, which evaluated parameters such as: area, biomass, average thickness, maximum thickness and roughness coefficient. Qualitative analysis was also performed to assess the architecture and bacterial viability. Data were submitted to Kolmogorov-Smirnov test and Kruskal-Wallis tests at 5% of significance. The results showed no statistical difference between the materials studied for the selected parameters, although the Filtek Supreme e IPS E.Max showed a higher amount of viable cells compared to other restorative materials. Thus, it was concluded that the quantitative analysis did not showed a significant influence of the restorative material on the structural characteristics of the biofilm. However, the qualitative analysis showed variations in bacterial viability on different restorative materials. In chapter 2 - The methodology employed in the manufacture and preparation of the specimens was the same used in Chapter 1. The specimens were submitted to the reading of hardness, roughness analysis, Scanning Electron Microscopy and Energy Dispersive X-Ray analysis before and after biodegradation. The data were subjected to the Kolmogorov-Smirnov and Tukey-Kramer test, at a significance level of 5%. All esthetic restorative materials showed a significant increase in roughness values after biodegradation. For the analysis of hardness, Vitremer, Ketac Molar Easymix and Amalgam Gs-80 demonstrated significant increase in the values after biodegradation. The initial chemical composition of the Amalgam GS-80 and IPS E.Max was not change by the action of biofilms in situ, while Filtek Supreme, Ketac Molar Easymix and Vitremer showed changes in their spectra, with fluoride release from glass ionomer materials and incorporation ions (Ca2+, Cl-) on the surface of some materials analyzed (Filtek Supreme, Ketac Molar Easymix and Vitremer).Under the conditions of this study, one can conclude that the effects of biofilm on the surface properties are material-dependent / Doutorado / Materiais Dentarios / Doutora em Materiais Dentários

Page generated in 0.0938 seconds