• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2841
  • 1046
  • 507
  • 267
  • 221
  • 132
  • 71
  • 71
  • 33
  • 16
  • 15
  • 13
  • 12
  • 11
  • 11
  • Tagged with
  • 6671
  • 2419
  • 1766
  • 1008
  • 998
  • 908
  • 701
  • 698
  • 696
  • 646
  • 612
  • 583
  • 566
  • 532
  • 515
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
721

Single Cell Force Spectroscopy for Quantification of Cellular Adhesion on Surfaces

January 2016 (has links)
abstract: Cell adhesion is an important aspect of many biological processes. The atomic force microscope (AFM) has made it possible to quantify the forces involved in cellular adhesion using a technique called single cell force spectroscopy (SCFS). AFM based SCFS offers versatile control over experimental conditions for probing directly the interaction between specific cell types and specific proteins, surfaces, or other cells. Transmembrane integrins are the primary proteins involved in cellular adhesion to the extra cellular matix (ECM). One of the chief integrins involved in the adhesion of leukocyte cells is αMβ2 (Mac-1). The experiments in this dissertation quantify the adhesion of Mac-1 expressing human embryonic kidney (HEK Mac-1), platelets, and neutrophils cells on substrates with different concentrations of fibrinogen and on fibrin gels and multi-layered fibrinogen coated fibrin gels. It was shown that multi-layered fibrinogen reduces the adhesion force of these cells considerably. A novel method was developed as part of this research combining total internal reflection microscopy (TIRFM) with SCFS allowing for optical microscopy of HEK Mac-1 cells interacting with bovine serum albumin (BSA) coated glass after interacting with multi-layered fibrinogen. HEK Mac-1 cells are able to remove fibrinogen molecules from the multi-layered fibrinogen matrix. An analysis methodology for quantifying the kinetic parameters of integrin-ligand interactions from SCFS experiments is proposed, and the kinetic parameters of the Mac-1 fibrinogen bond are quantified. Additional SCFS experiments quantify the adhesion of macrophages and HEK Mac-1 cells on functionalized glass surfaces and normal glass surfaces. Both cell types show highest adhesion on a novel functionalized glass surface that was prepared to induce macrophage fusion. These experiments demonstrate the versatility of AFM based SCFS, and how it can be applied to address many questions in cellular biology offering quantitative insights. / Dissertation/Thesis / Doctoral Dissertation Physics 2016
722

Caracterizacao microestrutural e mecanica da superliga a base de niquel (liga 600) apos tratamentos termicos

FERNANDES, STELA M. de C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:37:38Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:20Z (GMT). No. of bitstreams: 1 05329.pdf: 16832851 bytes, checksum: 8ef7bf6a007d858e609a66ba4b70e107 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
723

Caracterizações mecânicas e microestruturais do aço AISI 8630 modificado revestido com a liga de níquel 625 por soldagem 'GTAW' / Mechanical and microstructural characterizations of AISI 8630 modified cladded with nickel alloy 625 made by the TIG process after simulated Post Weld Heat Treatment cycles

CANTARIN, TADEU N. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:30Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:36Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
724

Estudos do desenvolvimento e caracterização das ligas Cu-Ni-Pt e Cu-Ni-Sn para fins eletro-eletrônicos

SILVA, LUIS C.E. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:52:22Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:47Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
725

Estudo da resistencia a corrosao de acos inoxidaveis para uso na parte fria dos sistemas de exaustao de veiculos

DI CUNTO, JULIO C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:09Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:23Z (GMT). No. of bitstreams: 1 11249.pdf: 6810896 bytes, checksum: d6d7eb3261a4e010e1840b22fdcc9f8a (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
726

Estudo comparativo morfologico da acao do laser de ND:YAG em dentina cariada de dentes deciduos in vitro, condicionados com diamino fluoreto de prata a 12 porcento e carvao mineral

CALMON, ANDREA de A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:45:54Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:38Z (GMT). No. of bitstreams: 1 07502.pdf: 4952377 bytes, checksum: 85fd543d0ec39abc66de35a76d9b1bbb (MD5) / Dissertacao (Mestrado Profissionalizante em Lasers em Odontologia) / IPEN/D-MPLO / Intituto de Pesquisas Energeticas e Nucleares, Sao Paulo; Faculdade de Odontologia, Universidade de Sao Paulo, Sao Paulo
727

Estudo das propriedades mecanicas e dos mecanismos de fratura de fibras sinteticas do tipo nailon e poliester em tecidos de engenharia / Study of mechanical properties and fracture mechanisms of synthetic fibers like nylon and polyester in engineering fabrics

CARDOSO, SERGIO G. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:27:24Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:51Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
728

Influencia da preparacao previa de amostras de aco AISI H 13 no comportamento a nitretacao

ALMEIDA FILHO, AMERICO de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:52Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:26Z (GMT). No. of bitstreams: 1 06769.pdf: 4275325 bytes, checksum: f2158eb766fa7886249500f40de27cec (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares, IPEN-CNEN/SP / FAPESP:97/04424-5
729

Physicochemical Characterization of PZT-Based Ultrasonic Transducer Stacks

January 2018 (has links)
abstract: A piezoelectric transducer, comprised of electroded and active pad PZT layer atop a backing PZT layer and protected with an acoustic matching layer, and operating under a pulse-echo technique for longitudinal ultrasonic imaging, acts as both source and detector. Ultrasonic transducer stacks (modules), which had failed or passed during pulse-echo sensitivity testing, were received from Consortium X. With limited background information on these stacks, the central theme was to determine the origin(s) of failure via the use of thermal and physicochemical characterization techniques. The optical and scanning electron microscopy revealed that contact electrode layers are discontinuous in all samples, while delaminations between electrodes and pad layer were observed in failed samples. The X-ray diffraction data on the pad PZT revealed an overall c/a ratio of 1.022 ratio and morphotropic boundary composition, with significant variations of the Zr to Ti ratio within a sample and between samples. Electron probe microanalysis confirmed that the overall Zr to Ti ratio of the pad PZT was 52/48, and higher amounts of excess PbO in failed samples, whereas, inductively coupled plasma mass spectrometry revealed the presence of Mn, Al, and Sb (dopants) and presence of Cu (sintering aid) in in this hard (pad) PZT. Additionally, three exothermic peaks during thermal analysis was indicative of incomplete calcination of pad PZT. Moreover, transmission electron microscopy and scanning transmission electron microscopy revealed the presence of parylene at the Ag-pad PZT interface and within the pores of pad PZT (in failed samples subjected to electric fields). This further dilutes the electrical, mechanical, and electromechanical properties of the pad PZT, which in turn detrimentally influences the pulse echo sensitivity. / Dissertation/Thesis / Masters Thesis Materials Science and Engineering 2018
730

Alteracoes na superficie de implantes de titanio apos a irradiacao com laser de Nd:YAG

ROMERA, ROGERIO F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:24Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:56:27Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado Profissionalizante em Lasers em Odontologia) / IPEN/D-MPLO / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP; Faculdade de Odontologia, Universidade de Sao Paulo, Sao Paulo

Page generated in 0.0445 seconds