Spelling suggestions: "subject:"miniinvasive"" "subject:"noninvasive""
1 |
Miniaturisation des technologies d'imagerie de fluorescence pour assister la chirurgie mini-invasive / The miniaturization of fluorescence image guided technologies to assist minimally invasive surgeryDorval, Paul 25 February 2015 (has links)
L’imagerie de fluorescence est une technique d’imagerie médicale permettant de visualiser l’émission d’un traceur, ou fluorophore, à l’aide d’une excitation de type Laser ou LED. Les domaines d’application de la technologie sont la chirurgie oncologique, la chirurgie reconstructive ou encore la chirurgie cardiaque. Bien que les besoins en chirurgie ouverte soient importants, l’évolution des pratiques tend à démocratiser la chirurgie dite minimalement invasive. La chirurgie endoscopique va dans ce sens, le but étant de limiter les traumatismes opératoires rencontrés en chirurgie ouverte. Parmi les avantages de cette techniques on note une diminution des saignements et de la douleur, ou encore une réduction de la durée d’hospitalisation.Lors d’une intervention de type chirurgie ouverte, le praticien peur se contenter de la seuls information de fluorescence fournie par le système d’imagerie. Cependant, tout l’enjeu de l’imagerie de fluorescence pour la chirurgie mini-invasive est de venir greffer ne information relative au fluorophore sur une image couleur de très bonne qualité, essentielle au chirurgien. Pour une première évaluation, un système deux caméras a été réalisé. Un capteur est dédié à l’acquisition de l’image couleur et un autre à l’information de fluorescence. Cependant, notamment pour conserver pour conserver un système compact et proposer la meilleure ergonomie possible au chirurgien, l’endoscope final ne devra comporter qu’un seul imageur. Le principe de base est d’utiliser des impulsions de lumière d’excitation et de lumière blanche afin de séquentiellement acquérir les données de fluorescence et les images couleur. Il convient ensuite de traiter les informations recueillies pour reconstruire l’image désirée en temps réel. / Fluorescence image-guided surgery is a medical imaging modality which allows the surgeon to visualize a fluorescent probe previously injected to the patient. The probe could be specific or not and the technology is useful in a wide range of application from oncologic procedures to reconstructive surgeries or cardiac procedures. Despite the important needs of this technology in open-procedures, the surgery in general is more and more minimally invasive. The goal of mini-invasive surgery is to limit patient's per and post operation trauma. The advantages of the technique are a decrease of bleeding and pain and a decreasing hospitalization time.During an open surgery, the B&W fluorescence information given by the fluorescence image-guided surgery system is enough for the surgeon. For mini-invasive procedures, the in-game is to overlay the fluorescence information to high quality color image, compulsory for the surgeon to perform his procedure. As a first evaluation, a 2-sensors system has been rapidly developed. One sensor is dedicated to the acquisition of the color image and the other to the fluorescence information. In order to make the system more compact and improve the quality of the color image furnished to the surgeon, the final system should be composed of only one sensor. To create the color image and collect the fluorescence information with one sensor, the technique involved pulsed white light and excitation light in a sequential acquisition mode. The two information are combined and a real-time color plus fluorescence video is displayed to the surgeon.
|
2 |
Commande en Effort des Systèmes Robotiques pour la Chirurgie Mini-InvasiveZemiti, Nabil 05 December 2005 (has links) (PDF)
Mettre en oeuvre un retour d'effort pour un système robotique dédié à la chirurgie mini-invasive impose d'adresser deux difficultés principales. La première est d'ordre métrologique, puisqu'il est technologiquement très difficile de procéder à une mesure directe de l'interaction distale à l'intérieur du patient, tout en respectant les contraintes de stérilité et d'encombrement. La seconde concerne le contrôle d'interactions dont la géométrie et la dynamique sont fortement variables et mal connues (contacts avec des organes, le chirurgien, ou d'autres instruments) dans un contexte particulier où la contrainte cinématique induite par le passage des instruments par un point fixe ne permet pas l'asservissement de toutes les composantes du torseur d'interaction.<br />La réponse apportée à ces questions prend ici la forme d'un système robotique bâti autour :<br />- d'un bras compact de cinématique sphérique ;<br />- d'un capteur d'efforts placé à l'extérieur du patient permettant une estimation fine des interactions distales ;<br />- d'une commande en effort dont la passivité est garantie pour toutes les interactions ; celle-ci est déclinée selon plusieurs modes (retour explicite, commande en impédance, téléopération à retour d'efforts).<br /><br />L'ensemble des propositions méthodologiques est validé de façon systématique sur un prototype de laboratoire développé dans le cadre de ce travail. Les expériences incluent des validations in vivo sur animal, depuis des tâches élémentaires jusqu'à l'utilisation du prototype comme "main gauche" pour une opération de cholécystectomie.
|
3 |
Conception optimale d'instruments robotisés à haute mobilité pour la chirurgie mini-invasiveSallé, Damien 06 December 2004 (has links) (PDF)
Cette thèse concerne la conception optimale de systèmes robotisés à haute mobilité pour la chirurgie mini-invasive. Elle este basée sur un processus d'optimisation par algorithmes évolutionnaires mult-objectifs, couplés à une simulation réaliste de la tache chirurgicale qui prend en compte tous les paramètres nécessaires à l'évaluation fidèle des robots. Cette méthodologie de conception a été appliquée au geste de suture lors d'une procédure de pontage coronarien. Elle aboutit à l'obtention d'un instrument chirurgical robotisé adapté, doté de 9 degrés de liberté: DRIMIS. Un prototype en a été réalisé et ses performances cinématiques évaluées.
|
4 |
Conception et modélisation d'une plateforme flexible d'endoscopie digestiveCauche, Nicolas 16 October 2014 (has links)
Les endoscopes utilisés en gastro-entérologie ne permettent pas d’obtenir une réelle chirurgie dans le tube digestif en passant par les voies naturelles. Cette thèse a pour ambition de pallier ce manquement grâce au développement d’une plate-forme de triangulation universelle. Cette plateforme donne la possibilité au gastro-entérologue d’augmenter de manière significative ses possibilités thérapeutiques en lui permettant de réaliser des actes chirurgicaux de base tels que “soulever-couper” et “suturer” les tissus. Ces actes ne peuvent être réalisés qu’extrêmement difficilement avec les endoscopes conventionnels. Ils constituent pourtant les éléments essentiels en vue de traiter l’obésité morbide ou le traitement du reflux gastro-oesophagien par les voies naturelles. La caractéristique principale de la plate-forme développée dans cette thèse est son universalité lui permettant une utilisation avec pratiquement n’importe quel type d’endoscope et outils thérapeutiques existants sur le marché. La plate-forme a obtenu le marquage CE. Des études cliniques ont été réalisées avec cet instrument dans le cadre du traitement de l’obésité. Cette thèse comprend également une méthodologie de conception pour des guidages flexibles utilisés dans le domaine médical. Cette méthodologie basée sur l’élaboration d’abaques théoriques permet, d’une part, à partir des desiderata du médecin, d’identifier les paramètres externes (rigidité, longueur.) d’un guidage flexible et ce peu importe le type de guidage utilisé et, d’autre part, de déduire les paramètres internes associés à ces paramètres externes pour un type de guidage particulier: un élastomère renforcé par un ressort hélicoïdal. La méthode a été appliquée `a posteriori `a la plate-forme de triangulation et donne, dans ce cas, de bons résultats. Flexible endoscopes used in gastro-enterology do not allowed a real surgery in the gastrointestinal tract passing through natural orifices. This thesis aimed to overcome these limitations by developing a universal triangulation platform. This platform allows the gastro-enterologist to significantly increase his therapeutic possibilities by enabling him to perform basic surgical procedures such as "lifting-cutting" and "suturing" the tissues. These procedures can only be performed with extreme difficulty with conventional endoscopes. They are, however, the essential elements for the treatment of morbid obesity or gastroesophageal reflux through natural orifice. The main feature of the platform developed in this thesis is its universality allowing it to be used with any type of endoscopes and existing tools available on the market. The platform has obtained the CE marking. Clinical studies have been conducted with this instrument for treatment of obesity. This thesis includes also a design methodology for flexible guides used in the medical field. This methodology, based on the elaboration of theoretical abacuses, allows, firstly, from the physician's specifications, to identify the external parameters (rigidity, length .) of the flexible guide regardless of the type of the used guide. Secondly, it allows to determine the internal parameters associated with these external parameters for a particular type of guide: an elastomer reinforced by a helical spring. The method was applied a posteriori to the triangulation platform and, in this case, gives good results. / Doctorat en Sciences de l'ingénieur et technologie / info:eu-repo/semantics/nonPublished
|
5 |
Real-time tracking of deformable targets in 3D ultrasound sequences / Suivi temps-réel de cibles dans des séquences de volumes échographiquesRoyer, Lucas 06 December 2016 (has links)
De nos jours, les traitements mini-invasifs, tels que l'ablation par radiofréquence, sont de plus en plus utilisés car ils permettent d'éliminer localement les tumeurs à partir de l'insertion d'une aiguille. Cependant, le succès de ces procédures dépend de la précision du positionnement de l'aiguille par rapport aux structures anatomiques. Afin de garantir un placement correct, l'imagerie échographique est souvent utilisée car elle a l'avantage d'être temps-réelle, bas coût, et non-invasive. En revanche, celle modalité peut compliquer la visualisation de certaines structures en raison de sa qualité et de son champ de vue limité. En outre, la précision des interventions peut aussi être perturbée par les déplacements de tissus liés aux mouvements physiologiques du patient et à la manipulation d'instruments médicaux. Afin d'aider le chirurgien à mieux cibler certaines structures anatomiques, de nombreuses équipes de recherche ont proposé des travaux permettant d'estimer la position de régions d'intérêts dans l'imagerie échographique. Cette thèse propose plusieurs contributions permettant de suivre en temps réel des structures déformables dans des séquences d'échographie 3D. Une première contribution repose sur l'utilisation conjointe de l'information visuelle dense et d'une méthode de simulation physique. Dans cette thèse, nous avons aussi proposé un nouveau critère de similarité spécifique à l'imagerie échographique basé sur une étape de détection d'ombres. Enfin, la dernière contribution est liée à une stratégie de suivi hybride permettant d'améliorer la qualité des images. A partir de ces contributions, nous proposons une méthode de suivi robuste au bruit de type« speckle », aux ombres et aux changements d'intensité perturbant l'imagerie échographique. Les performances des différentes contributions sont évaluées à partir de données simulées et de données acquises sur maquettes et sur volontaires humains. Ces résultats montrent que notre méthode est robuste à différents artefacts de l'imagerie échographique. En outre, nous démontrons la performance de notre approche par rapport à différentes méthodes de l'état de l'art sur des bases de données publiques fournies par les challenges MICCAI CLUST'14 et CLUST'15. Dans cette thèse, nous proposons également une application permettant de combiner l'imagerie échographique à l'imagerie par résonance magnétique (IRM). Cette méthode permet d'observer des structures anatomiques non-visibles dans l'imagerie échographique durant l'intervention. Elle est basée sur la combinaison d'une méthode de suivi et d'un recalage multi-modal obtenu à partir d'un système de localisation externe. Cette application a été évaluée sur un volontaire sain à partir d'une plateforme liée au centre Hospitalier Universitaire de Rennes. / Nowadays, mini-invasive treatments, such as radio-frequency ablation, are increasingly being used because they allow eliminating tumors locally from needle insertion. However, the success of these therapies depends on the accurate positioning of the needle with respect to anatomical structures. To ensure correct placement, ultrasound (US) imaging is often used since this system has the advantage to be real-time, low-cost, and non-invasive. However, during the intervention, US imaging can complicate the visualization of targeted structures due to its poor quality and its limited field of view. Furthermore, the accuracy of these interventions may also be perturbed by both physiological movements and medical tools displacements that introduce motions of anatomical structures. To help the surgeon to better target malignant tissues, many research teams have proposed different method in order to estimate the position of regions of interest in ultrasound imaging. This thesis provides several contributions that allow tracking deformable structures in 3D ultrasound sequences. We first present a method that allows providing robust estimation of target positions by combining an intensity-based approach and mechanical model simulation. In this thesis, we also propose novel ultrasound-specific similarity criterion based on prior step that aims at detecting shadows. The last contribution is related to a hybrid tracking strategy that allows improving quality of ultrasound images. From these contributions, we propose a tracking method that has the advantage to be invariant to speckle noise, shadowing and intensity changes that can occur in US imaging. The performance and limitations of the proposed contributions are evaluated through simulated data, phantom data, and real-data obtained from different volunteers. Simulation and phantom results show that our method is robust to several artefacts of US imaging such as shadows and speckle decorrelation. Furthermore, we demonstrate that our approach outperforms state-of-the-art methods on the 3D public databases provided by MICCAI CLUST'14 and CLUST'15 challenges. In this thesis, we also propose an application that combines ultrasound imaging to Magnetic Resonance lmaging (MRI). This method allows observing anatomical structures that are not visible in US imaging during the intervention. It is based on the combination between US tracking method and multi modal registration obtained from external localization system. This application was evaluated on a volunteer thanks to an MRJ imaging platform locate at the University Hospital of Rennes.
|
6 |
Conception et réalisation d'une instrumentation terminale intégrée en chirurgie mini-invasive robotiséeVAN MEER, Frederick 28 January 2005 (has links) (PDF)
On assiste depuis quelques années à l'émergence d'une robotique médicale proposée pour accroître la précision des actes, améliorer les conditions de travail de l'équipe chirurgicale et le confort du patient. Nos recherches s'inscrivent dans le projet national EndoXiroB du RNTS dont l'objectif est la réalisation d'un ensemble robotisé de chirurgie mini-invasive. Elles sont dédiées à la conception et à la réalisation, en s'appuyant sur les technologies microsystèmes, d' une instrumentation chirurgicale poly-articulée équipée d'outils terminaux intégrés permettant une mesure des efforts et une découpe thermo-coagulante des tissus vivants. Nous présenterons une description complète de notre proposition qui consiste en une articulation poly-articulée innovante, proche du type « corps de serpent ». Cette articulation, commandée par quatre ou six fils, est composée de liaisons rotules plastiques accompagnées par plusieurs fils métalliques assurant à l'ensemble une rigidité en torsion et flexion. Nous décrirons nos travaux sur la conception microsystème d'un capteur d'effort deux axes pour mesurer des forces de tiraillement sur les tissus. Le microsystème utilise deux niveaux de silicium intégrant un corps d'épreuve à quatre branches orthogonales et un ensemble d'électrodes capacitives inter-digitées.Nous exposerons nos premières études sur la conception de lames thermo-chauffantes pour la découpe et la coagulation des tissus. Ces études sont basées sur la réalisation de lames en technologie silicium. Au-delà de la simple découpe et de la mesure des efforts, on peut imaginer d'intégrer d'autres micro-capteurs sur les outils chirurgicaux. Il serait ainsi possible d'augmenter la sécurité de l'acte chirurgical en évaluant, par exemple, la présence d'artères, de vaisseaux ou de nerfs à proximité de l'outil de chirurgie. Pour finir, nous proposerons une réflexion plus prospective basée sur la miniaturisation d'un robot portable intégrant un dispositif compact pour actionner l'a rticulation terminale de l'instrument chirurgical. Au-delà de cette réflexion, une solution extrême consisterait dans le futur à transférer tous les degrés de liberté d'un système robotisé à l'intérieur de la cavité opératoire.
|
7 |
Télé-opération avec retour d'effort pour la chirugie mini-invasiveZarrad, Walid 19 December 2007 (has links) (PDF)
Ces travaux de thèse s'inscrivent dans le cadre de l'assistance robotique pour la chirurgie mini-invasive télé-opérée. L'une des principales limitations des systèmes existants concerne l'absence de restitution des efforts au chirurgien lorsqu'il télé-opère le robot. Ainsi, un système de télé-opération avec retour d'effort est proposé. Il est basé sur une architecture position - position avec une commande en effort du robot esclave. Cette dernière utilise un découplage non-linéaire du robot ainsi que des techniques d'observation et de commande par retour d'état. Des validations expérimentales ont montré les performances de l'architecture lors d'une télé-opération en espace libre et lors d'interactions avec un environnement de faible rigidité. Une première contribution est l'estimation en ligne de la raideur de l'environnement afin de garantir la stabilité du système lors d'interactions avec un environnement rigide. Cette stratégie utilise un filtre de Kalman étendu qui s'affranchit de la position de repos de l'environnement et qui considère une compensation des erreurs de modélisation du robot esclave. La deuxième contribution est l'étude de la transparence et de la stabilité de l'architecture de télé-opération. Une adaptation des paramètres de commande en fonction de la raideur estimée est proposée en considérant un compromis entre ces deux critères. La structure a été validée expérimentalement en considérant un environnement constitué de tissus ex-vivo. Une dernière contribution est l'adaptation de l'architecture de télé-opération avec retour d'effort aux contraintes imposées par la chirurgie mini-invasive. La première est le passage de l'instrument du robot par le trocart. Une architecture de commande utilisant le principe du découplage tâche - posture est alors proposée. La posture permettant le passage par le trocart est contrôlée en considérant la commande en position d'un robot virtuel attaché à l'instrument du robot télé-opéré. La deuxième contrainte considérée est la compensation des mouvements physiologiques. L'objectif étant d'offrir au chirurgien une stabilisation virtuelle de l'organe. L'approche de commande consiste à atténuer les perturbations dans les efforts appliqués sur un environnement en mouvement. La compensation repose sur une commande référencée modèle qui considère que les perturbations atténuées génèrent un déplacement du robot esclave. Des expérimentations ont montré la pertinence et l'efficacité des stratégies proposées.
|
8 |
Chirurgie cardiaque mini-invasive : du concept à l'évaluation d'une instrumentation spécifique / Mini-invasive cardiac surgery : from the concept to the evaluation of dedicated implementsJegaden, Olivier 17 October 2012 (has links)
Ce travail reprend les études d’évaluation d’une plateforme instrumentale dédiée à la chirurgie mitrale mini-invasive vidéo-assistée, et du télémanipulateur Da Vinci pour la réalisation d’anastomose mammaire interne / IVA à thorax fermé.) Evaluation du Portaclamp. Cette étude clinique a porté sur 20 patients opérés de chirurgie cardiaque sous CEC et a confirmé la simplicité d’utilisation du système, son efficacité et l’absence de morbidité ou complication induite. L’étude chez le porc des effets histologiques sur la paroi de l’aorte des trois clamps (l’endo-clamp, le clamp Chitwood et le Portaclamp) a révélé une atteinte majeure de l’endothélium aortique induite par l’endo-clamp . 2) Evaluation du Portapleg. Le Portapleg est un dispositif auto-suturant de cardioplégie antérograde constitué d’un clip en Nitinol restant implanté sur l’aorte. Une étude sur 20 patients a été rapportée avec comme critère principal le temps de saignement du site de ponction après injection de protamine. Le système a montré son efficacité hémostatique dans tous les cas sans événement secondaire. 3) Evaluation du Mitrax’s. C’est un cône en plastique polymère auto ajustable et auto expansible, qui repousse de façon symétrique et concentrique les parois de l’oreillette. Une étude prospective de son efficacité a été réalisée chez 62 patients opérés de chirurgie mitrale vidéo-assistée de façon consécutive. L’indice de satisfaction a été en moyenne 4.6, témoin d’une exposition optimale de la valve mitrale avec une vision endoscopique ou directe de la valve mitrale jugée excellente. 4) Analyse comparative des techniques mini-invasives de revascularisation de l’IVA par pontage mammaire (Port Access, MIDCAB, TECAB). Cette étude prospective a porté sur 160 patients ; à trois mois, le taux de réintervention sur l’IVA était : PA-CABG, 0% ; MIDCAB, 1.8% ; TECAB, 10% ; p<0.01. A trois ans, les taux actuariels de survie sans réintervention étaient : PA-CABG, 100% ; MIDCAB, 98±5 % ; TECAB, 88±8 % ; p<0.05. / This thesis is based on the evaluation studies of an instrumental platform dedicated to video assisted minimally invasive mitral valve surgery, and of the robotic Da Vinci system in LAD bypass with mammary artery in a closed chest approach. 1) Evaluation of Portaclamp. In 20 patients who underwent cardiac surgery with Portaclamp, a clinical study showed that the clamping system is safe, fast and easy and does not generate undue morbidity. In a pig model, severe lesions of the intima were observed on the clamping spot with the endoclamp, in comparison with Portaclamp and Chitwood clamp. 2) Evaluation of Portapleg. Portapleg is an auto-suturing system dedicated to antegrade cardioplegia delivery, and based on a Nitinol clip left implanted on the aorta. In 20 patients, the closure of the puncture aortic hole and the haemostasis after protamine were obtained in all cases. The procedure did not generate undue morbidity and there was no device-related adverse event. 3) Evaluation of Mitrax’s. The Mitrax’s retractor is a pattern cut polymer sheet, self-expanding and auto-adjusting. The effectiveness of Mitrax’s was evaluated in 62 patients who consecutively underwent a video-assisted mitral valve procedure. The global satisfaction index was 4.6±0.5, demonstrating the effectiveness of the device which provides optimal exposure and excellent direct vision. 4) Comparative analysis of minimally invasive techniques for LAD revascularization with mammary artery graft (Port Access, MIDCAB, TECAB). In a prospective study, 160 patients were included. At 3-month postoperatively, the end-point of LAD reintervention were PA-CABG, 0%; MIDCAB, 1.8%; TECAB, 10%; p=0.01. At 3-year, reintervention-free survival was significantly lower in the TECAB group: PA-CABG, 100% ; MIDCAB, 98±5 % ; TECAB, 88±8 % ; p<0.05.
|
9 |
Guidage par Réalité Augmentée : Application à la Chirurgie Cardiaque RobotiséeMourgues, Fabien 29 September 2003 (has links) (PDF)
La chirurgie mini-invasive limite les incisions et le traumatisme pour le patient. Elle bénéficie de l'assistance robotisée qui améliore précision et confort du geste opératoire. Cependant des difficultés subsistent. Ainsi dans les opérations de pontage des artères coronaires, la localisation et l'identification des artères cibles de l'intervention posent problème. Nous proposons alors de guider le chirurgien en superposant le modèle des artères du patient dans les images endoscopiques intra-opératoires. L'une des contributions de cette thèse consiste à définir une approche basée sur l'analyse de l'intervention et du geste chirurgical: tout d'abord nous nous intéressons à la modélisation statique des artères coronaires à partir de moyens standards d'imagerie. Nous initialisons ensuite le recalage dans les images endoscopiques en calibrant l'endoscope stéréoscopique robotisé et en recalant l'enveloppe externe du patient au bloc opératoire. Nous affinons enfin ce résultat pour tenir compte du déplacement intra-opératoire du coeur et des erreurs successives. Un mécanisme multi-modèles robuste original, basé sur la traduction des indications données par le chirurgien en mesures, permet d'aboutir à la précision nécessaire au guidage. Cet outil novateur de chirurgie assistée par ordinateur est intégré au sein d'une architecture commune expérimentée avec le robot Da Vinci au cours de nombreux tests in-vivo.
|
10 |
Modélisation d'un système de navigation chirurgicale pour le traitement par radio-fréquences des tumeurs du foie / Development of a Computer Assisted System aimed at RFA Liver SurgeryMundeleer, Laurent L 24 September 2009 (has links)
Radiofrequency ablation (RFA) is a minimally invasive treatment for either hepatocellular carcinoma or metastasis liver carcinoma. In order to resect large lesions, the surgeon has to perform multiple time-consuming destruction cycles and reposition the RFA needle for each of them. The critical step in handling a successful ablation and preventing local recurrence is the correct positioning of the needle. For small tumors, the surgeon places the middle of the active needle tip in the center of the tumor under intra-operative ultrasound guidance. When one application is not enough to cover the entire tumor, the surgeon needs to repeat the treatment after repositioning of the needle, but US guidance is obstructed by the opacity stemming from the first RFA application. In this case the surgeon can only rely on anatomical knowledge and the repositioning of the RFA needle becomes a subjective task limiting the treatment accuracy. We have developed a computer assisted surgery guidance application for this repositioning procedure. Our software application handles the complete process from preoperative image analysis to tool tracking in the operating room. Our framework is mostly used for this RFA procedure, but is also suitable for any other medical or surgery application.
|
Page generated in 0.0509 seconds