• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 1
  • Tagged with
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

"Desenvolvimento de instrumentação e procedimentos analíticos automáticos para a determinação espectrofotométrica de tensoativos em águas" / "Development of the instrumentation and automatic analytical procedures for spectrophotometric determination of surfactants in waters"

Lavorante, André Fernando 23 February 2006 (has links)
"Neste trabalho, propõe-se o desenvolvimento de instrumentação e procedimentos analíticos automáticos para a determinação de tensoativos em águas empregando o conceito de multicomutação em fluxo. Visando a miniaturização do sistema, a minimização do consumo de reagentes, e da geração de efluentes foram utilizadas mini-bombas solenóide para a propulsão dos fluidos e válvulas solenóide de estrangulamento para controlar a manipulação das soluções. Estes dispositivos foram controlados por um microcomputador equipado com uma interface eletrônica baseada no circuito integrado ULN2803A a qual foi acoplada à saída da impressora. Como sistema de detecção foram empregados um espectrofotômetro HP8452A, um espectrofotômetro multicanal com arranjo linear de fotodetectores do tipo CCD e um fotômetro baseado em dois LEDs (azul e vermelho) como fonte de radiação e um fotodiodo de silício (IPL10530DAL) como detector. A aquisição dos dados do fotômetro foi realizada com um multímetro digital com saída serial RS232, empregando um programa escrito em linguagem VISUAL BASIC 3.0. No mesmo programa foram incluídas rotinas para controle do módulo de análise. Primeiramente, foram desenvolvidos a instrumentação e os procedimentos analíticos para a determinação independente de tensoativos aniônicos e catiônicos em águas. O mesmo módulo de análises foi utilizado para os dois tensoativos e foi constituído de quatro mini-bombas solenóide. O procedimento proposto para a determinação de tensoativos aniônicos foi baseado na substituição do reagente cromogênico alaranjado de metila (MO) pelo tensoativo aniônico dodecilbenzeno sulfonato de sódio (DBS), formando o par-iônico com o tensoativo catiônico cloreto de cetilpiridino (CPC) em pH 5,0. A instrumentação proposta possibilitou a obtenção de resposta linear entre 1,4 x 10-6 mol L-1 e 1,4 x 10-5 mol L-1 (0,5 - 5 mg L-1) (R = 0,997, n = 7), limite de detecção de 9,8 x 10-8 mol L-1 (0,034 mg L-1), e freqüência de amostragem de 60 determinações por hora. O desvio padrão relativo foi estimado em 0,8 % (n = 11) usando uma solução de referência contendo 5,7 x 10-6 mol L-1 (2 mg L-1) de DBS. Os resultados obtidos pelo método proposto processando amostras de efluentes domésticos e industriais foram comparados com os obtidos empregando-se o método de referência, e não foi observada diferença significativa em nível de confiança de 95 %. Para a determinação de tensoativos catiônicos em águas foi desenvolvido um procedimento baseado na formação do complexo ternário entre tensoativo catiônico CPC, Fe (III) e cromazurol S (CAS) em pH 4,5. Com o sistema proposto, utilizando-se uma cela de detecção de 40 mm de comprimento, obteve-se resposta linear entre 0,1 x 10-5 mol L-1 e 3,0 x 10-5 mol L-1 (0,34 - 10,2 mg L-1) (R = 0,999, n = 9), limite de detecção estimado em 1,0 x 10-7 mol L-1 (0,035 mg L-1), desvio padrão relativo de 0,6 % (n = 11) empregando uma solução de referência contendo 1,0 x 10-5 mol L-1 (3,4 mg L-1) de CPC, e freqüência de amostragem de 72 determinações por hora. O procedimento foi aplicado em amostras de águas coletadas no rio Piracicaba. Empregando-se teste de adição e recuperação foi observada recuperação entre 91 % e 106 %. O módulo de análise para a determinação seqüencial de tensoativos aniônicos e catiônicos foi constituído de duas mini-bombas solenóide e seis válvulas solenóide de estrangulamento. Com o sistema proposto, as características analíticas para os tensoativos aniônicos foram: resposta linear entre 0,1 x 10-5 mol L-1 e 3,0 x 10-5 mol L-1 (0,35 - 10,5 mg L-1) (R = 0,9992, n = 7); limite de detecção estimado em 1,6 x 10-7 mol L-1 (0,056 mg L-1); desvio padrão relativo de 0,6 % (n = 11) usando uma solução de referência contendo 1,0 x 10-5 mol L-1 (3,5 mg L-1) de DBS. Para os tensoativos catiônicos obteve-se resposta linear entre 0,1 x 10-5 mol L-1 e 3,0 x 10?5 mol L-1 (0,34 - 10,2 mg L-1) (R = 0,9992, n = 7); limite de detecção estimado em 1,4 x 10-7 mol L-1 (0,05 mg L-1); desvio padrão relativo de 0,5 % (n = 11) usando uma solução de referência contendo 1,0 x 10-5 mol L-1 (3,4 mg L-1) de CPC. O consumo das soluções de reagentes e de amostra foram de 400 mL e 200 mL, respectivamente, e freqüência de amostragem de 60 determinações por hora, para ambos tensoativos. O sistema foi aplicado em amostras de águas coletadas no rio Corumbataí, e os resultados obtidos com testes de adição e recuperação variaram entre 91 % e 105 %. Aplicando-se teste-t entre os resultados obtidos pelo procedimento proposto e pelos métodos de referência (aniônicos) e de validação (catiônicos), os resultados foram concordantes em nível de 95 % de confiança." / "In this work, development of the instrumentation and automatic analytical procedures for spectrophotometric determination of surfactants in waters employing the multicommutation concept were proposed. Aiming to system miniaturization, reduction of reagents consumption and effluents generation, solenoids micro-pump and solenoids pinch valves were used for the fluids propulsion and for solutions management, respectively. These devices were controlled by a microcomputer equipped with an electronic interface based on the integrate circuit ULN2803A that was coupled to the printer output. As system detection was employed an spectrophotometer model HP8452A, a multichannel spectrophotometer with CCD array linear arrangement of photodetectors and a homemade LED based photometer comprising two LEDs (blue and red) as radiation source and a photodiode (IPL10530DAL) as detector. In this case, the data acquisition was accomplished with a digital multimeter with serial out put RS232 employing a software wrote in VISUAL BASIC 3.0. The software comprised also routines to control the analysis module. Firstly, instrumentation and analytical procedures for independent determination of anionic and cationic surfactants in waters were developed. The same flow system comprised of four solenoid micro-pumps and it was employed for both surfactants. The procedure proposed for the determination of anionic surfactant was based on the substitution reaction of orange methyl (MO) by anionic surfactant (sodium dodecylbenzene sulfonate - DBS) to form an ion-pair with the cetyl pyridine (CPC) at pH 5.0. The proposed instrumentation allowed the achievement of a lineal response range between 1.4 x 10-6 mol L-1 and 1.4 x 10-5 mol L-1 (0.5 – 5.0 mg L-1) (R = 0.997, n = 7), a detection limit of 9.8 x 10-8 mol L-1 (0.034 mg L-1), a relative standard deviation of 0.8% (n = 11) for a reference solution containing 5.7 x 10-6 mol L-1 (2.0 mg L-1) DBS and sampling throughput of 60 determinations per hour. Results obtained applying the proposed procedure for domestic and industrial effluent samples were compared with those obtained using reference method and no significant differences at the 95 % confidence level was observed. For the determination of cationic surfactant in waters the procedure was developed based on the ternary complex formation between CPC, Fe (III) and chromazurol S at pH 4.5. The proposed system comprised a flow cell device with 40 mm optical path-length presented the following features: a linear response range between 0.1 x 10-5 mol L-1 e 3.0 x 10-5 mol L-1 (0.34 – 10.2 mg L-1) (R = 0.999, n = 9); a detection limit of 1.0 x 10-7 mol L-1 (0.035 mg L-1); a relative standard deviation of 0.6 % (n = 11) for a reference solution containing 1.0 x 10-5 mol L-1 (3.4 mg L-1) CPC; and a sampling throughput of 72 determinations per hour. The procedure was applied to samples waters collected in the Piracicaba River. Using standard addition test recoveries between 91 % and 106 % were observed. The flow network for the sequential determination of anionic and cationic surfactants comprised two solenoid micro-pumps and six solenoid pinch valves. Employing the system proposed for the determination of anionic surfactants the folowing analytical characteristics: linear response range between 0.1 x 10-5 mol L-1 e 3.0 x 10-5 mol L-1 (0.35 – 10.5 mg L-1) (R = 0.9992, n = 7); a detection limit of 1.6 x 10-7 mol L-1 (0.056 mg L-1); a relative standard deviation of 0.6 % (n = 11) for a reference solution containing 1.0 x 10-5 mol L-1 (3.5 mg L-1) DBS were observed. For cationic surfactants a linear response range between 0.1 x 10-5 mol L-1 e 3.0 x 10?5 mol L-1 (0.34 - 10.2 mg L-1) (R = 0.9992, n = 7), a detection limit of 1.4 x 10-7 mol L-1 (0.05 mg L-1), a relative standard deviation of 0.5 % (n = 11) for a reference solution containing 1.0 x 10-5 mol L-1 (3.4 mg L-1) CPC were observed. In both cases, the reagents and sample consumption were 400 mL and 200 mL, respectively. The sampling throughput of 60 determinations per hour was achieved for both surfactants. The system was applied to waters samples from the Corumbataí River. The results obtained using the standard addition test presented recoveries between 91 % and 105 %. Applying t-test between the results obtained by the proposed procedures and those obtained using reference procedures showed that for anionic and cationic surfactants, the results were concordant at 95% confidence level."
2

"Desenvolvimento de instrumentação e procedimentos analíticos automáticos para a determinação espectrofotométrica de tensoativos em águas" / "Development of the instrumentation and automatic analytical procedures for spectrophotometric determination of surfactants in waters"

André Fernando Lavorante 23 February 2006 (has links)
"Neste trabalho, propõe-se o desenvolvimento de instrumentação e procedimentos analíticos automáticos para a determinação de tensoativos em águas empregando o conceito de multicomutação em fluxo. Visando a miniaturização do sistema, a minimização do consumo de reagentes, e da geração de efluentes foram utilizadas mini-bombas solenóide para a propulsão dos fluidos e válvulas solenóide de estrangulamento para controlar a manipulação das soluções. Estes dispositivos foram controlados por um microcomputador equipado com uma interface eletrônica baseada no circuito integrado ULN2803A a qual foi acoplada à saída da impressora. Como sistema de detecção foram empregados um espectrofotômetro HP8452A, um espectrofotômetro multicanal com arranjo linear de fotodetectores do tipo CCD e um fotômetro baseado em dois LEDs (azul e vermelho) como fonte de radiação e um fotodiodo de silício (IPL10530DAL) como detector. A aquisição dos dados do fotômetro foi realizada com um multímetro digital com saída serial RS232, empregando um programa escrito em linguagem VISUAL BASIC 3.0. No mesmo programa foram incluídas rotinas para controle do módulo de análise. Primeiramente, foram desenvolvidos a instrumentação e os procedimentos analíticos para a determinação independente de tensoativos aniônicos e catiônicos em águas. O mesmo módulo de análises foi utilizado para os dois tensoativos e foi constituído de quatro mini-bombas solenóide. O procedimento proposto para a determinação de tensoativos aniônicos foi baseado na substituição do reagente cromogênico alaranjado de metila (MO) pelo tensoativo aniônico dodecilbenzeno sulfonato de sódio (DBS), formando o par-iônico com o tensoativo catiônico cloreto de cetilpiridino (CPC) em pH 5,0. A instrumentação proposta possibilitou a obtenção de resposta linear entre 1,4 x 10-6 mol L-1 e 1,4 x 10-5 mol L-1 (0,5 - 5 mg L-1) (R = 0,997, n = 7), limite de detecção de 9,8 x 10-8 mol L-1 (0,034 mg L-1), e freqüência de amostragem de 60 determinações por hora. O desvio padrão relativo foi estimado em 0,8 % (n = 11) usando uma solução de referência contendo 5,7 x 10-6 mol L-1 (2 mg L-1) de DBS. Os resultados obtidos pelo método proposto processando amostras de efluentes domésticos e industriais foram comparados com os obtidos empregando-se o método de referência, e não foi observada diferença significativa em nível de confiança de 95 %. Para a determinação de tensoativos catiônicos em águas foi desenvolvido um procedimento baseado na formação do complexo ternário entre tensoativo catiônico CPC, Fe (III) e cromazurol S (CAS) em pH 4,5. Com o sistema proposto, utilizando-se uma cela de detecção de 40 mm de comprimento, obteve-se resposta linear entre 0,1 x 10-5 mol L-1 e 3,0 x 10-5 mol L-1 (0,34 - 10,2 mg L-1) (R = 0,999, n = 9), limite de detecção estimado em 1,0 x 10-7 mol L-1 (0,035 mg L-1), desvio padrão relativo de 0,6 % (n = 11) empregando uma solução de referência contendo 1,0 x 10-5 mol L-1 (3,4 mg L-1) de CPC, e freqüência de amostragem de 72 determinações por hora. O procedimento foi aplicado em amostras de águas coletadas no rio Piracicaba. Empregando-se teste de adição e recuperação foi observada recuperação entre 91 % e 106 %. O módulo de análise para a determinação seqüencial de tensoativos aniônicos e catiônicos foi constituído de duas mini-bombas solenóide e seis válvulas solenóide de estrangulamento. Com o sistema proposto, as características analíticas para os tensoativos aniônicos foram: resposta linear entre 0,1 x 10-5 mol L-1 e 3,0 x 10-5 mol L-1 (0,35 - 10,5 mg L-1) (R = 0,9992, n = 7); limite de detecção estimado em 1,6 x 10-7 mol L-1 (0,056 mg L-1); desvio padrão relativo de 0,6 % (n = 11) usando uma solução de referência contendo 1,0 x 10-5 mol L-1 (3,5 mg L-1) de DBS. Para os tensoativos catiônicos obteve-se resposta linear entre 0,1 x 10-5 mol L-1 e 3,0 x 10?5 mol L-1 (0,34 - 10,2 mg L-1) (R = 0,9992, n = 7); limite de detecção estimado em 1,4 x 10-7 mol L-1 (0,05 mg L-1); desvio padrão relativo de 0,5 % (n = 11) usando uma solução de referência contendo 1,0 x 10-5 mol L-1 (3,4 mg L-1) de CPC. O consumo das soluções de reagentes e de amostra foram de 400 mL e 200 mL, respectivamente, e freqüência de amostragem de 60 determinações por hora, para ambos tensoativos. O sistema foi aplicado em amostras de águas coletadas no rio Corumbataí, e os resultados obtidos com testes de adição e recuperação variaram entre 91 % e 105 %. Aplicando-se teste-t entre os resultados obtidos pelo procedimento proposto e pelos métodos de referência (aniônicos) e de validação (catiônicos), os resultados foram concordantes em nível de 95 % de confiança." / "In this work, development of the instrumentation and automatic analytical procedures for spectrophotometric determination of surfactants in waters employing the multicommutation concept were proposed. Aiming to system miniaturization, reduction of reagents consumption and effluents generation, solenoids micro-pump and solenoids pinch valves were used for the fluids propulsion and for solutions management, respectively. These devices were controlled by a microcomputer equipped with an electronic interface based on the integrate circuit ULN2803A that was coupled to the printer output. As system detection was employed an spectrophotometer model HP8452A, a multichannel spectrophotometer with CCD array linear arrangement of photodetectors and a homemade LED based photometer comprising two LEDs (blue and red) as radiation source and a photodiode (IPL10530DAL) as detector. In this case, the data acquisition was accomplished with a digital multimeter with serial out put RS232 employing a software wrote in VISUAL BASIC 3.0. The software comprised also routines to control the analysis module. Firstly, instrumentation and analytical procedures for independent determination of anionic and cationic surfactants in waters were developed. The same flow system comprised of four solenoid micro-pumps and it was employed for both surfactants. The procedure proposed for the determination of anionic surfactant was based on the substitution reaction of orange methyl (MO) by anionic surfactant (sodium dodecylbenzene sulfonate - DBS) to form an ion-pair with the cetyl pyridine (CPC) at pH 5.0. The proposed instrumentation allowed the achievement of a lineal response range between 1.4 x 10-6 mol L-1 and 1.4 x 10-5 mol L-1 (0.5 – 5.0 mg L-1) (R = 0.997, n = 7), a detection limit of 9.8 x 10-8 mol L-1 (0.034 mg L-1), a relative standard deviation of 0.8% (n = 11) for a reference solution containing 5.7 x 10-6 mol L-1 (2.0 mg L-1) DBS and sampling throughput of 60 determinations per hour. Results obtained applying the proposed procedure for domestic and industrial effluent samples were compared with those obtained using reference method and no significant differences at the 95 % confidence level was observed. For the determination of cationic surfactant in waters the procedure was developed based on the ternary complex formation between CPC, Fe (III) and chromazurol S at pH 4.5. The proposed system comprised a flow cell device with 40 mm optical path-length presented the following features: a linear response range between 0.1 x 10-5 mol L-1 e 3.0 x 10-5 mol L-1 (0.34 – 10.2 mg L-1) (R = 0.999, n = 9); a detection limit of 1.0 x 10-7 mol L-1 (0.035 mg L-1); a relative standard deviation of 0.6 % (n = 11) for a reference solution containing 1.0 x 10-5 mol L-1 (3.4 mg L-1) CPC; and a sampling throughput of 72 determinations per hour. The procedure was applied to samples waters collected in the Piracicaba River. Using standard addition test recoveries between 91 % and 106 % were observed. The flow network for the sequential determination of anionic and cationic surfactants comprised two solenoid micro-pumps and six solenoid pinch valves. Employing the system proposed for the determination of anionic surfactants the folowing analytical characteristics: linear response range between 0.1 x 10-5 mol L-1 e 3.0 x 10-5 mol L-1 (0.35 – 10.5 mg L-1) (R = 0.9992, n = 7); a detection limit of 1.6 x 10-7 mol L-1 (0.056 mg L-1); a relative standard deviation of 0.6 % (n = 11) for a reference solution containing 1.0 x 10-5 mol L-1 (3.5 mg L-1) DBS were observed. For cationic surfactants a linear response range between 0.1 x 10-5 mol L-1 e 3.0 x 10?5 mol L-1 (0.34 - 10.2 mg L-1) (R = 0.9992, n = 7), a detection limit of 1.4 x 10-7 mol L-1 (0.05 mg L-1), a relative standard deviation of 0.5 % (n = 11) for a reference solution containing 1.0 x 10-5 mol L-1 (3.4 mg L-1) CPC were observed. In both cases, the reagents and sample consumption were 400 mL and 200 mL, respectively. The sampling throughput of 60 determinations per hour was achieved for both surfactants. The system was applied to waters samples from the Corumbataí River. The results obtained using the standard addition test presented recoveries between 91 % and 105 %. Applying t-test between the results obtained by the proposed procedures and those obtained using reference procedures showed that for anionic and cationic surfactants, the results were concordant at 95% confidence level."
3

Desenvolvimento de um equipamento portátil e de sistema de análises em fluxo empregando multicomutação. Determinação fotométrica de ferro em águas de rios / Development of a portable equipment and a flow analysis system employing multicommutation. Photometric determination of iron in river waters

Miranda, Jeová Correia 20 July 2011 (has links)
O ferro é o elemento mais abundante na Terra e tem importante papel em ciclos biogeoquímicos Neste trabalho foi desenvolvido um procedimento analítico automático para a determinação fotométrica de ferro em águas de rios, empregando um fotômetro baseado em LED e mini-bombas solenoide para o gerenciamento de soluções. O procedimento proposto foi baseado na reação do ferro (III) com o tiocianato de potássio formando um complexo avermelhado com máximo de absorção em 470 nm. Para a determinação de ferro total foi incluída uma etapa de oxidação em linha, usando uma solução de persulfato (S2O82-) como oxidante. O módulo de análises foi constituído por quatro mini-bombas solenoide e uma válvula solenoide de três vias. Para a obtenção de sinais foi construído um fotômetro composto por uma cela de fluxo com caminho óptico de 50 mm, um LED azul (\'lâmbda\'=470 nm) e um fotodetector. Visando utilizar este equipamento portátil para medidas em campo, foram empregadas duas baterias de 6 V para alimentar os dispositivos ativos. Os ensaios em laboratório mostraram que as baterias permitem uma autonomia de mais de 50 horas de trabalho sem recarregá-las. O procedimento desenvolvido apresentou as seguintes características analíticas: resposta linear entre as concentrações de 0,25 e 4,0 mg L-1, segundo a equação Y = (0,0183 ± 0,003) + (0,15326 ± 0,002)X (r=0,9997); limite de detecção 0,013 mg L-1 Fe (III) estimado com 99,7 % de confiança; desvio padrão relativo estimado em 0,95 % (n=15) obtido com uma solução de concentração de 1,5 mg L-1 Fe (III); frequência de amostragem de 50 determinações por hora. Os resultados obtidos pelo procedimento proposto e pelo de referência não apresentaram diferenças significativas com nível de confiança de 95 % / Iron is the most abundant element on Earth and plays an important role in biogeochemical cycles. In this work, an automatic analytical procedure was developed for the photometric determination of iron in river waters, employing a LED-based photometer and solenoid mini-pumps for solution handling. The proposed procedure was based on the reaction between iron (III) and potassium thiocyanate, yielding a red complex with maximum absorption at 470 nm. For the determination of total iron, an in line oxidation step was included, employing a persulfate solution (S2O82-) as oxidant. The module was constructed with four solenoid mini-pumps and a three-way solenoid valve. For data acquisition a photometer was constructed with a 50 mm optical path flow cell, a blue LED (\'lâmbda\'= 470 nm) and a photodetector. Envisioning the use of this portable equipment in field, two 6-Volt batteries were employed to supply energy to the active devices. Laboratory tests showed that the batteries provide more than 50 hours of operation without recharging. The proposed procedure showed the following analytical features: linear response between 0.25 and 4.0 mg L-1, according to the equation Y = (0.0183 ± 0.003) + (0.15326 ± 0.002) X (r = 0.9997); detection limit of 0.013 mg L-1 Fe (III), estimated with 99.7 % of confidence; relative standard deviation estimated as 0.95% (n = 15), obtained with a 1.5 mg L-1 Fe (III) solution; sampling rate of 50 determinations per hour.The results obtained with the proposed and reference procedure did not show significative differences at a 95% confidence level
4

\"Sistemas de análises químicas em fluxo explorando multi-impulsão e detecção espectrofotométrica: aplicação a formulações farmacêuticas e a extratos de solos\" / Multi-pumping flow systems with spectrophotometric detection: application to analysis of pharmaceuticals and soil extracts

Dias, Ana Cristi Basile 21 March 2006 (has links)
Os sistemas de análises em fluxo com multi-impulsão (MP) empregam bombas solenóides como unidade propulsora de fluidos, as quais proporcionam um fluxo pulsante. Esta característica foi avaliada em função do funcionamento, operação e desempenho do sistema, das condições de mistura entre as soluções envolvidas e da dispersão da solução inserida. A avaliação geral dos sistemas MP envolveu estudos de precisão e exatidão volumétrica dos pulsos, bem como da robustez da unidade propulsora, os quais envolveram medidas gravimétricas. Ainda, dispersão envolvendo uma solução colorida como amostra foi espectrofotometricamente avaliada. Os resultados foram corroborados por meio de aplicações analíticas. Limitações quanto ao uso de bombas com maiores volumes de pulso (> 25 l) foram observadas a elevadas frequências de pulsação (> 4,0 Hz). Os volumes experimentalmente determinados concordaram com os valores esperados (erro relativo < 2,0 %). A dispersão da amostra foi menor relativamente àquela inerente a fluxo constante (sistema explorando multi-comutação, MC). O fluxo pulsante promoveu melhoria no desenvolvimento reacional devido principalmente à agitação dos elementos de fluido vizinhos. Este aspecto foi importante com relação à determinação espectrofotométrica de bromexina em fármacos. O método se fundamentou no acoplamento eletrofílico da bromexina com 3-metil-2-benzotiazolinona hidrazona (MBTH), e posterior oxidação com Ce(IV) em ambiente ácido. Boa sensibilidade analítica foi conseguida com baixo consumo de reagentes e rapidez nas análises (300 h-1). O sistema comparativo, envolvendo fluxo constante, não apresentou a mesma sensibilidade analítica. Outra aplicação foi a determinação espectrofotométrica de fosfato em extratos de solos envolvendo a formação do azul de molibdênio. Melhores resultados analíticos foram obtidos para freqüências de pulsação < 0,5 Hz, devido ao maior tempo disponível para a interação entre as espécies quínicas envolvidas. O sistema MP proposto requer menor volume de amostra (48 l) relativamente ao sistema MC (96 l), sendo caracterizado por maior frequência analítica (MP: 144 h-1; MC: 67 h-1). Os resultados referentes às análises de extratos de solos foram concordantes entre si e com relação ao método referência. A visualização de uma amostra se dispersando no fluxo pulsante foi possível empregando-se a técnica de despolarização da fluorescencia induzida por laser envolvendo Rodamina B. Os experimentos foram conduzidos sob alta (3,0 Hz) ou baixa (0,5 Hz) freqüência de pulsação na inserção de amostra, ausência ou presença de reator entre o local de introdução de amostra e o detector, e sentido horizontal ou vertical da cela de fluxo. Análise dos gráficos obtidos permitiu se vizualizar a re-distribuição de massas em função do tempo. Em geral, observou-se formação de vórtices no centro da zona de amostra e uma migração bastante intensa no sentido radial. No sentido axial, melhores interações amostra / fluxo transportador foram observadas quando a freqüência de pulsação foi baixa e em presença de um reator de 60 cm. O estabelecimento de vórtices resultou em uma mistura bastante rápida e pontual, o que foi confirmado pelas aplicações analíticas / Multi-pumping flow systems (MP) utilize solenoid pumps as fluid propelling devices, which deliver pulsed flows. This feature was evaluated in relation to the design, operation and performance of the system, to the mixing conditions, and to the dispersion of the introduced solution. The general evaluation of the MP systems involved investigations about precision and accuracy of the pulse volumes, as well as the pump ruggedness. To this end, gravimetric measurements were carried out. Moreover, dispersion was evaluated by exploiting a colored solution and spectrophotometric monitoring. Results were corroborated through analytical applications. Use pumps delivering higher pulse volumes (> 25 l) was limited when the pulsation frequency was > 4.0 Hz. The experimentally measured volumes were in agreement with to the expected values (relative error < 2.0 %). Sample dispersion was lower in relation to that inherent to laminar flow (multi-commuted flow system, MC).Exploitation of pulsed flow led to a enhanced reaction development mainly due to shaking of neighboring fluid elements. This aspect was important in relation to spectrophotometric determination of bromhexine in pharmaceuticals The method was based on electrophylic coupling of bromhexine with 3-methyl-2-benzothiazolinone hydrazone (MBTH), with further oxidation by Ce(IV) under acidic medium. Analytical sensitivity was fair, reagent consumption was low and sampling rate was 300 h-1. These figures of merit were not compared with those inherent to the MC system due to the lack of sensitivity of this system. Another application was the spectrophotometric determination of phosphate in soil extracts relying the molybdenum blue formation. Best analytical results were obtained for < 0.5 Hz pulse frequency, due to the higher available time for interaction among the involved chemical species. The proposed MP system required lower sample volume (48 l) in relation to the MC system (96 l), being characterized by higher sampling rate (MP: 144 h-1; MC: 67 h-1). Analytical results related to soil extracts were in agreement between them and with the reference method. Visualization of a dispersing sample in a pulsed flow became feasible using the laser induced fluorescence technique applied to Rhodamine B, RB. Experiments were performed under high (3.0 Hz) or low (0.5 Hz) pulse frequency, optional insertion of a reactor between the injection point and detection, and vertical or horizontal positioning of the flow-cell. Analyses of the graphs obtained allowed the visualization of the mass re-distribution in function of time. In general, vortex formation at the central portion of the sample zone and a high RB migration in the radial direction, were noted. Concerning axial direction, better sample / carrier stream interactions were observed for lower pulse frequency and insertion of the 60-cm reactor. Vortex establishment led to a punctual and fast mixing, as confirmed by the analytical applications
5

\"Sistemas de análises químicas em fluxo explorando multi-impulsão e detecção espectrofotométrica: aplicação a formulações farmacêuticas e a extratos de solos\" / Multi-pumping flow systems with spectrophotometric detection: application to analysis of pharmaceuticals and soil extracts

Ana Cristi Basile Dias 21 March 2006 (has links)
Os sistemas de análises em fluxo com multi-impulsão (MP) empregam bombas solenóides como unidade propulsora de fluidos, as quais proporcionam um fluxo pulsante. Esta característica foi avaliada em função do funcionamento, operação e desempenho do sistema, das condições de mistura entre as soluções envolvidas e da dispersão da solução inserida. A avaliação geral dos sistemas MP envolveu estudos de precisão e exatidão volumétrica dos pulsos, bem como da robustez da unidade propulsora, os quais envolveram medidas gravimétricas. Ainda, dispersão envolvendo uma solução colorida como amostra foi espectrofotometricamente avaliada. Os resultados foram corroborados por meio de aplicações analíticas. Limitações quanto ao uso de bombas com maiores volumes de pulso (> 25 l) foram observadas a elevadas frequências de pulsação (> 4,0 Hz). Os volumes experimentalmente determinados concordaram com os valores esperados (erro relativo < 2,0 %). A dispersão da amostra foi menor relativamente àquela inerente a fluxo constante (sistema explorando multi-comutação, MC). O fluxo pulsante promoveu melhoria no desenvolvimento reacional devido principalmente à agitação dos elementos de fluido vizinhos. Este aspecto foi importante com relação à determinação espectrofotométrica de bromexina em fármacos. O método se fundamentou no acoplamento eletrofílico da bromexina com 3-metil-2-benzotiazolinona hidrazona (MBTH), e posterior oxidação com Ce(IV) em ambiente ácido. Boa sensibilidade analítica foi conseguida com baixo consumo de reagentes e rapidez nas análises (300 h-1). O sistema comparativo, envolvendo fluxo constante, não apresentou a mesma sensibilidade analítica. Outra aplicação foi a determinação espectrofotométrica de fosfato em extratos de solos envolvendo a formação do azul de molibdênio. Melhores resultados analíticos foram obtidos para freqüências de pulsação < 0,5 Hz, devido ao maior tempo disponível para a interação entre as espécies quínicas envolvidas. O sistema MP proposto requer menor volume de amostra (48 l) relativamente ao sistema MC (96 l), sendo caracterizado por maior frequência analítica (MP: 144 h-1; MC: 67 h-1). Os resultados referentes às análises de extratos de solos foram concordantes entre si e com relação ao método referência. A visualização de uma amostra se dispersando no fluxo pulsante foi possível empregando-se a técnica de despolarização da fluorescencia induzida por laser envolvendo Rodamina B. Os experimentos foram conduzidos sob alta (3,0 Hz) ou baixa (0,5 Hz) freqüência de pulsação na inserção de amostra, ausência ou presença de reator entre o local de introdução de amostra e o detector, e sentido horizontal ou vertical da cela de fluxo. Análise dos gráficos obtidos permitiu se vizualizar a re-distribuição de massas em função do tempo. Em geral, observou-se formação de vórtices no centro da zona de amostra e uma migração bastante intensa no sentido radial. No sentido axial, melhores interações amostra / fluxo transportador foram observadas quando a freqüência de pulsação foi baixa e em presença de um reator de 60 cm. O estabelecimento de vórtices resultou em uma mistura bastante rápida e pontual, o que foi confirmado pelas aplicações analíticas / Multi-pumping flow systems (MP) utilize solenoid pumps as fluid propelling devices, which deliver pulsed flows. This feature was evaluated in relation to the design, operation and performance of the system, to the mixing conditions, and to the dispersion of the introduced solution. The general evaluation of the MP systems involved investigations about precision and accuracy of the pulse volumes, as well as the pump ruggedness. To this end, gravimetric measurements were carried out. Moreover, dispersion was evaluated by exploiting a colored solution and spectrophotometric monitoring. Results were corroborated through analytical applications. Use pumps delivering higher pulse volumes (> 25 l) was limited when the pulsation frequency was > 4.0 Hz. The experimentally measured volumes were in agreement with to the expected values (relative error < 2.0 %). Sample dispersion was lower in relation to that inherent to laminar flow (multi-commuted flow system, MC).Exploitation of pulsed flow led to a enhanced reaction development mainly due to shaking of neighboring fluid elements. This aspect was important in relation to spectrophotometric determination of bromhexine in pharmaceuticals The method was based on electrophylic coupling of bromhexine with 3-methyl-2-benzothiazolinone hydrazone (MBTH), with further oxidation by Ce(IV) under acidic medium. Analytical sensitivity was fair, reagent consumption was low and sampling rate was 300 h-1. These figures of merit were not compared with those inherent to the MC system due to the lack of sensitivity of this system. Another application was the spectrophotometric determination of phosphate in soil extracts relying the molybdenum blue formation. Best analytical results were obtained for < 0.5 Hz pulse frequency, due to the higher available time for interaction among the involved chemical species. The proposed MP system required lower sample volume (48 l) in relation to the MC system (96 l), being characterized by higher sampling rate (MP: 144 h-1; MC: 67 h-1). Analytical results related to soil extracts were in agreement between them and with the reference method. Visualization of a dispersing sample in a pulsed flow became feasible using the laser induced fluorescence technique applied to Rhodamine B, RB. Experiments were performed under high (3.0 Hz) or low (0.5 Hz) pulse frequency, optional insertion of a reactor between the injection point and detection, and vertical or horizontal positioning of the flow-cell. Analyses of the graphs obtained allowed the visualization of the mass re-distribution in function of time. In general, vortex formation at the central portion of the sample zone and a high RB migration in the radial direction, were noted. Concerning axial direction, better sample / carrier stream interactions were observed for lower pulse frequency and insertion of the 60-cm reactor. Vortex establishment led to a punctual and fast mixing, as confirmed by the analytical applications
6

Materiais inorgânicos associados a sistemas multicomutados para a determinação de espécie químicas em alimentos

LEOTERIO, Dilmo Marques da Silva 21 March 2016 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2017-05-30T13:01:39Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE DILMO MARQUES_2016.pdf: 3410115 bytes, checksum: ef2c4a31a389b0d7af33d59ec444fa24 (MD5) / Made available in DSpace on 2017-05-30T13:01:39Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE DILMO MARQUES_2016.pdf: 3410115 bytes, checksum: ef2c4a31a389b0d7af33d59ec444fa24 (MD5) Previous issue date: 2016-03-21 / CNPQ / Neste trabalho foram desenvolvidos métodos analíticos, baseados no conceito de multicomutação, para análise de espécies químicas em alimentos. Para isto, foram sintetizados dois materiais: um composto de coordenação usado como fase sólida na determinação de açúcares redutores e uma rede de sílica utilizada como resina de pré-concentração de percloratos. O composto de coordenação cobre (II) - 4,4 '- bipiridina foi usado no desenvolvimento do método para a determinação de açúcares redutores em água de coco e sucos empregando sistema em fluxo multicomutado com detecção espectrofotométrica. A metodologia de análise baseou-se na reação de oxi-redução em meio alcalino entre o reagente sólido e os açúcares redutores. A reação entre a fase sólida (de coloração azul) com (glicose + frutose) resulta em produto de cor amarelada, monitorada em 420 nm. A fase sólida foi fixada em 50 mg e temperatura de 90ºC. Com volume de zona de amostragem de 160 L, que corresponde a 20 ciclos, obtendo resposta linear entre 1,0 e 20,0 g L-1 de AR com RSD de 4,47% (n = 7 ), limite de detecção de 0,2250 g L-1, limite de quantificação de 0,7496 g L-1, freqüência analítica de 75 determinções por hora e geração de efluentes de 320 μL por determinação. Os teores de açúcar redutor encontrados em sucos e água de coco variaram de 38,35 a 98,50 g L-1 e 61,80 a 68,70 g L-1 respectivamente. A rede de sílica, 2,5,8,11,14-pentaoxa-1-silaciclotetradecano, foi empregada num sistema multicomutado como coluna de pré-concentração de perclorato. O sistema foi acoplado a um detector potenciométrico para determinar percloratos em vegetais. Usou-se um eletrodo tubular com membrana constituída por 1% (m/m) de BNIP 4,4 Dapm LC1 solubilizado em 68% (m/m) de 2-nitrodifeniléter, como solvente mediador e 31% (m/m) de poli (cloreto de vinila). Obteve-se limite de detecção de 2,8x10-7 mol L-1, resposta linear no intervalo de 1,0x10-9 a 1,0x10-1 mol L-1, coeficiente de correlação linear de 0,9998 e a coluna apresentou uma capacidade de retenção de 2,86x10-3 mol de perclorato. O sistema foi aplicado às amostras de diferentes vegetais e foram encontradas concentrações de percloratos de 1,30 a 5,08 µg L-1 o teste recuperação variou de 96,5 a 110,8 %. / Two new multicommutation-based analytical methods were developed aiming to the quantification of chemical species in food. The first method is intended to the determination of reducing sugars in coconut water and fruit juices, while the second one is a potentiometric determination of perchlorates in horticultural products. The method eveloped for the determination of reducing sugars uses a multicommuted flow system with spectrophotometric detection employing a (copper (II) - 4,4’ – bipyridyl) coordination compound as the solid-phase reagent. The reaction of the solid blue phase with glucose/fructose resulted in a yellowish solution, which was monitored at 420 nm; 50 mg of the solid phase was used and the temperature was set at 90ºC. The volume of the sample zone was, 160 L, corresponding to 20 cycles, with a linear response of 1.0 e 20.0 g L-1 to the RA and RSD of 4.47% (n = 7), detection limit of 0.2250 g L-1, the limit of quantification was 0.7496 g L-1, analytical frequency of 75 determination per hour and effluent generation of 320 L per determination. The potentiometric method used to determine perchlorates used a tubular electrode formed by a polymeric membrane which showed the best features consisted of 1% (w/w) BNIP Dapm LC1 solubilized in 68% (w/w) of 2-nitrodiphenyl ether as a mediator solvent and 31% (w/w) poly(vinyl chloride) as the polymeric matrix. A limit of detection of 2.8x10-7 mol L-1 was obtained with a linear response in the range of 1.0x10-9 at 1.0x10-1 mol L-1, linear correlation coefficient of 0.9998 and the column retention capacity 2.86x10-3 mol perchlorate. Was applied to samples of different vegetables found perchlorates 1.30 to 5.08 µg L-1 and recovery between 96.5 and 110.8%.
7

Desenvolvimento de um equipamento portátil e de sistema de análises em fluxo empregando multicomutação. Determinação fotométrica de ferro em águas de rios / Development of a portable equipment and a flow analysis system employing multicommutation. Photometric determination of iron in river waters

Jeová Correia Miranda 20 July 2011 (has links)
O ferro é o elemento mais abundante na Terra e tem importante papel em ciclos biogeoquímicos Neste trabalho foi desenvolvido um procedimento analítico automático para a determinação fotométrica de ferro em águas de rios, empregando um fotômetro baseado em LED e mini-bombas solenoide para o gerenciamento de soluções. O procedimento proposto foi baseado na reação do ferro (III) com o tiocianato de potássio formando um complexo avermelhado com máximo de absorção em 470 nm. Para a determinação de ferro total foi incluída uma etapa de oxidação em linha, usando uma solução de persulfato (S2O82-) como oxidante. O módulo de análises foi constituído por quatro mini-bombas solenoide e uma válvula solenoide de três vias. Para a obtenção de sinais foi construído um fotômetro composto por uma cela de fluxo com caminho óptico de 50 mm, um LED azul (\'lâmbda\'=470 nm) e um fotodetector. Visando utilizar este equipamento portátil para medidas em campo, foram empregadas duas baterias de 6 V para alimentar os dispositivos ativos. Os ensaios em laboratório mostraram que as baterias permitem uma autonomia de mais de 50 horas de trabalho sem recarregá-las. O procedimento desenvolvido apresentou as seguintes características analíticas: resposta linear entre as concentrações de 0,25 e 4,0 mg L-1, segundo a equação Y = (0,0183 ± 0,003) + (0,15326 ± 0,002)X (r=0,9997); limite de detecção 0,013 mg L-1 Fe (III) estimado com 99,7 % de confiança; desvio padrão relativo estimado em 0,95 % (n=15) obtido com uma solução de concentração de 1,5 mg L-1 Fe (III); frequência de amostragem de 50 determinações por hora. Os resultados obtidos pelo procedimento proposto e pelo de referência não apresentaram diferenças significativas com nível de confiança de 95 % / Iron is the most abundant element on Earth and plays an important role in biogeochemical cycles. In this work, an automatic analytical procedure was developed for the photometric determination of iron in river waters, employing a LED-based photometer and solenoid mini-pumps for solution handling. The proposed procedure was based on the reaction between iron (III) and potassium thiocyanate, yielding a red complex with maximum absorption at 470 nm. For the determination of total iron, an in line oxidation step was included, employing a persulfate solution (S2O82-) as oxidant. The module was constructed with four solenoid mini-pumps and a three-way solenoid valve. For data acquisition a photometer was constructed with a 50 mm optical path flow cell, a blue LED (\'lâmbda\'= 470 nm) and a photodetector. Envisioning the use of this portable equipment in field, two 6-Volt batteries were employed to supply energy to the active devices. Laboratory tests showed that the batteries provide more than 50 hours of operation without recharging. The proposed procedure showed the following analytical features: linear response between 0.25 and 4.0 mg L-1, according to the equation Y = (0.0183 ± 0.003) + (0.15326 ± 0.002) X (r = 0.9997); detection limit of 0.013 mg L-1 Fe (III), estimated with 99.7 % of confidence; relative standard deviation estimated as 0.95% (n = 15), obtained with a 1.5 mg L-1 Fe (III) solution; sampling rate of 50 determinations per hour.The results obtained with the proposed and reference procedure did not show significative differences at a 95% confidence level

Page generated in 0.0298 seconds