• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 177
  • 64
  • 23
  • 21
  • 20
  • 13
  • 11
  • 11
  • 6
  • 6
  • 3
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 418
  • 47
  • 40
  • 32
  • 32
  • 26
  • 25
  • 24
  • 23
  • 22
  • 22
  • 21
  • 20
  • 19
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Using under-road tunnels to protect a declining population of long-toed salamanders (Ambystoma macrodactylum) in Waterton Lakes National Park

Pagnucco, Katie Unknown Date
No description available.
192

Cross section measurements on 61Cu for proton beam monitoring above 20 MeV

Kuhn, S., Buchholz, M., Wels, T., Breunig, K., Scholten, B., Spahn, I., Coenen, H. H. 19 May 2015 (has links) (PDF)
Introduction All experimental studies involving charged particle induced nuclear reactions require a precise knowledge of monitor reactions. A number of well described proton induced monitor reactions exist in the lower energy range [1], which is covered by most medical cyclotrons. Concerning proton energies above 20 MeV, however, the accuracy of the monitor reactions declines as cross section data becomes scarcer. Furthermore, the growing interest in precise determination of projectile energies by comparing of ratios of monitor reaction cross sections demands new measurements and evaluations of known data for high threshold monitor radionuclides. In this work cross section measurements on the formation of 61Cu were done and energy de-pendent radionuclide ratios were calculated. Material and Methods For investigation of the natCu(p,x)61Cu reaction copper foils of natural isotopic composition (Goodfellow Ltd.) were irradiated. The targets were of 10 and 20 μm thickness, having a diameter of 15 mm. Proton bombardments up to 45 MeV incident energy were done in the stacked-foil arrangement at the accelerator JULIC of the Nuclear Physics Institute (IKP) of the Forschungszentrum Jülich. In addition to an internal irradiation possibility the cyclotron is equipped with an external target station which was used for most experiments. It can adapt standard and slanting solid target holders and is equipped with a water cooled four sector collimator and additional helium cooling of the entry foil. Several irradiations were executed. In each stack, besides copper samples, aluminium absorbers and additional nickel monitor foils were also placed, the latter for the determination of the respective beam current. The produced radioactivity of 61Cu was analysed non-destructively using HPGe γ-ray detectors (EG&G Ortec). Results and Conclusion Reaction cross sections of the natCu(p,x)61Cu process up to 45 MeV were measured and com-pared with existing data from the literature (FIG. 2). Except for the data of Williams et al. our results are in good agreement, showing a maxi-mum of about 165 mbarn at 37.5 MeV proton energy. The overall uncertainty of the new cross section data is between 8 and 10 %. In FIG. 3, the excitation functions of the relevant monitor reactions on Cu are shown. In combination with the excitation function of the natCu(p,xn)62Zn reaction, isotope ratios were calculated which can be used for determination of the proton energy within a target stack in the energy range of 22–40 MeV as described by Piel et al. [3]. FIGURE 4 shows the cross section ratio in dependence of the proton energy. Above this energy, 65Zn could be used to generate isotope ratios for energy determination, although the long half-life (T½ = 244.3 d) of that radionuclide may be a problem. Additional cross section measurements are planned in order to further strengthen the data base of this potential monitor reaction. The results of this work shall be evaluated in the framework of an ongoing Coordinated Research Project of the IAEA.
193

ENHANCED GRAIN CROP YIELD MONITOR ACCURACY THROUGH SENSOR FUSION AND POST-PROCESSING ALGORITHMS

Veal, Matthew Wayne 01 January 2006 (has links)
Yield monitors have become an indispensable part of precision agriculture systemsbecause of their ability to measure the yield variability. Accurate yield monitor data availabilityis essential for the assessment of farm practices. The current technology of measuring grainyields is prone to errors that can be attributed to mass flow variations caused by the mechanismswithin a grain combine. Because of throughput variations, there are doubts regarding thecorrelation between the mass flow measurement and the actual grain volume produced at aspecific location. Another inaccuracy observed in yield monitor data can be attributed to inexactcut-widths values entered by the machine operator.To effectively address these yield monitor errors, two crop mass flow sensing deviceswere developed and used to correct yield monitor data. The two quantities associated with cropmaterial mass flow that were sensed were tension on the feeder housing drive chain and thehydraulic pressure on the threshing cylinder's variable speed drive. Both sensing approacheswere capable of detecting zero mass flow conditions better than the traditional grain mass flowsensor. The alternative sensors also operate without being adversely affected by materialtransport delays. The feeder housing-based sensor was more sensitive to variations in cropmaterial throughput than the hydraulic pressure sensor. Crop mass flow is not a surrogate forgrain mass flow because of a weak relationship (R2 andlt; 0.60) between the two quantities. The cropmass flow signal does denote the location and magnitude of material throughput variations intothe combine. This delineation was used to redistribute grain mass flow by aligning grain andcrop mass flow transitions using sensor fusion techniques. Significant improvements (?? = 0.05)in yield distribution profile were found after the correction was applied.To address the cut-width entry error, a GIS-based post-processing algorithm wasdeveloped to calculate the true harvest area for each yield monitor data point. Based on theresults of this method, a combine operator can introduce yield calculation errors of 15%. Whenthese two correction methods applied to yield monitor data, the result is yield maps withdramatically improved yield estimates and enhanced spatial accuracy.
194

The design of a leakage current monitor for live line bare hand maintenance

de Beun, Arthur January 1992 (has links)
This thesis describes the design of an instrument for the protection of personnel carrying out live line bare hand maintenance of power transmission circuits. This instrument monitors the leakage current along equipment to ground and sounds an alarm when preset thresholds are exceeded. The leakage current monitor is microprocessor controlled, resulting in both flexible and user friendly operation. The prototype constructed, has been tested and found to perform very well.
195

Study of Collimated Neutron Flux Monitors for MAST and MAST Upgrade

Sangaroon, Siriyaporn January 2014 (has links)
Measurements of the neutron emission, resulting from nuclear fusion reactions between the hydrogen isotopes deuterium and tritium, can provide a wealth of information on the confinement properties of fusion plasmas and how these are affected by Magneto-Hydro-Dynamic (MHD) instabilities. This thesis describes work aimed to develop neutron measurement techniques for nuclear fusion plasma experiments, specifically regarding the performance and design of collimated neutron flux monitors (neutron cameras) for the Mega Ampere Spherical Tokamak, MAST, and for MAST Upgrade. The first part of the thesis focuses on the characterization of a prototype neutron camera installed at MAST and provides an account of the very first measurements of the neutron emissivity along its collimated fields of view. It is shown that the camera has sufficient temporal and spatial resolution to measure the effect of MHD instabilities on the neutron emissivity. The neutron camera fulfils the requirement on the measurements of the neutron count rate profile with less than 10 % statistical uncertainty in a time resolution of 1 ms. The instrument's more rudimentary capabilities to provide information on the neutron energy distribution are also presented and discussed. The encouraging results obtained with the prototype neutron camera show the potential of a collimated neutron flux monitor at MAST and suggest that an upgraded instrument for MAST Upgrade will provide crucial information on fast ions behavior and other relevant physics issues. The design of such an upgraded instrument for MAST Upgrade is discussed in the second part of the thesis. Two design options are explored, one consisting of two collimator arrays in the horizontal direction, another more traditional design with lines-of-sight in the poloidal cross section plane. On the basis of the experience gained with the prototype neutron camera and on the exploratory design and estimated performance for the upgraded camera presented here, a conceptual design of a neutron camera upgrade is proposed.
196

Eye opening monitor for optimized self-adaptation of low-power equalizers in multi-gigabit serial links

Narayanan, Anand January 2013 (has links)
In modern day communication systems, there is a constant demand for increase in transmission rates. This is however limited by the bandwidth limitation of the channel. Inter symbol interference (ISI) imposes a great threat to increasing data rates by degrading the signal quality. Equalizers are used at the receiver to compensate for the losses in the channel and thereby greatly mitigate ISI. Further, an adaptive equalizer is desired which can be used over a channel whose response is unknown or is time-varying. A low power equalizing solution in a moderately attenuated channel is an analog peaking filter which boosts the signal high frequency components. Such conventional continuous time linear equalizers (CTLE) provide a single degree of controllability over the high frequency boost. A more complex CTLE has been designed which has two degrees of freedom by controlling the high frequency boost as well as the range of frequencies over which the boost is applied. This extra degree of controllability over the equalizer response is desired to better adapt to the varying channel response and result in an equalized signal with a wider eye opening. A robust adaptation technique is necessary to tune the equalizer characteristics. Some of the commonly used techniques for adaptation of CTLEs are based on energy comparison criterion in the frequency domain. But the adaptation achieved using these techniques might not be optimal especially for an equalizer with two degrees of controllability. In such cases an eye opening monitor (EOM) could be used which evaluates the actual signal quality in time domain. The EOM gives an estimate on the signal quality by measuring the eye opening of the equalized signal in horizontal and vertical domain. In this thesis work a CTLE with two degrees of freedom with an EOM based adaptation system has been implemented.
197

A view screen beam profile monitor for the ARIEL e-linac at TRIUMF

Storey, Douglas Wesley 16 August 2011 (has links)
A megawatt class electron linear accelerator (e-linac) will be constructed at TRIUMF as part of the new ARIEL facility which will produce rare ion beams for the study of nuclear structure and astrophysics, and material science. The 50MeV, 10mA, continuous wave e-linac will drive gamma ray induced fissioning of a Uranium target for the production of neutron rich beam species. View Screens located at a number of places along the e-linac beam-line will acquire two dimensional images of the transverse electron beam profiles, providing measurements of the size, position, and shape of the incident e-linac beam. The design of the View Screens will be presented, based on design studies and simulations performed to evaluate the performance of the View Screens under various operating conditions. These studies include GEANT simulations of the energy loss and scattering of the electron beam as it passes through the scintillation and Optical Transition Radiation beam targets, the subsequent thermal response of the targets, and a ray tracing optics simulation to optimize the configuration of the imaging optics. Bench test have been performed on the resulting optics design to evaluate the imaging characteristics, verifying fulfillment of the design requirements. Construction of a prototype View Screen device is currently underway, with beam tests scheduled for Fall 2011. A total of 14 View Screens will be constructed and installed along the e-linac beam-line. / Graduate
198

A Suggested English Language Teaching Program For Gulhane Military Medical Academy

Sari, Rahim 01 January 2003 (has links) (PDF)
The purpose of this study is to evaluate the English teaching program at G&uuml / lhane Military Medical Faculty and suggest a new program based on the Monitor Model. The study, as an example of a systematic study of a language program and that of a proposed syllabus, is expected to aid the practice of English Language Teaching in Turkey. The data sources were 230 students, 25 doctors and 7 teachers. The data analysis showed that students do not like the contents of the course books. Students reported speaking and reading as priority skills. To understand and translate medical material, to get an overseas assignment, to talk to foreigners and to follow lectures were the common language-related goals. Students&amp / #8217 / , institution&amp / #8217 / s and doctors&amp / #8217 / needs and goals and available resources were surveyed and a new second language teaching program was suggested for Phase 1. A general curriculum model and a program design model were also suggested together with the syllabuses for Phase 1. In the suggested program, grammar, writing and other conscious learning activities are separated from comprehension or (subconscious) acquisition-based activities. The suggested design has three topic-based syllabuses organized in modular format for three levels: Advanced, intermediate and elementary. For the majority advanced level classes new materials need to be developed and for elementary and intermediate levels new course books are suggested. A sample module was prepared, piloted and the results are discussed. The piloted module was found better than the previous form of the lessons both by the students and the teachers.
199

Using under-road tunnels to protect a declining population of long-toed salamanders (Ambystoma macrodactylum) in Waterton Lakes National Park

Pagnucco, Katie 11 1900 (has links)
I investigated the value of under-road tunnels as a conservation strategy to protect a long-toed salamander population, in south-west Alberta, whose overwintering sites and breeding habitat (Linnet Lake) are separated by a road. I conducted a mark-recapture study from 2008-2009, capturing salamanders using roadside fences and pitfall traps. Four tunnels were monitored in 2009 using traps and cameras. A 2008 estimate indicated that the population declined by 60% since 1994, however, road mortality was dramatically reduced following installation of fences and tunnels. Camera and trap data documented 130 salamanders navigating tunnels in 2009. I found little evidence of juvenile recruitment from Linnet Lake, likely because of predation by lake chub. Experiments showed that lake chub consumed salamander larvae, and fish presence altered larval behaviour. Continued monitoring is needed to determine if reduced road mortality translates into population gains, and whether fish predation threatens the persistence of the long-toed salamander population. / Ecology
200

Dosimetric Investigation of Electron Arc Therapy Delivered Using Siemens Electron Arc Applicator with a Trapezoidal Aperture

Xing, Aitang January 2007 (has links)
This study investigated the delivery of electron arc treatment with a trapezoidal aperture. The aim of the investigation is to reduce the nonuniformity of the dose distribution, which is caused by the variation of the patient contour from superior to inferior. The characteristics of static electron beam were first investigated. Then a measurement-based algorithm was developed and implemented as a computer program called EarcMU to calculate the monitor units required for delivering the prescribed dose with a trapezoidal aperture. The central axis percentage depth dose was found to be independent of source-to-surface distance (SSD) and the width of the aperture. The inplane profiles of a trapezoidal aperture show that the dose decreases longitudinally from the wide to the narrow end of the trapezoidal aperture. The EarcMU program was verified using two cylindrical water phantoms. The measured dose and the dose calculated by the program agreed within 2.1% in the typical clinical conditions. A simple method was also proposed for determining the trapezoidal aperture for an individual patient. Under the same conditions, the trapezoidal apertures calculated by this method along with the open aperture were used to deliver treatments to several conical phantoms. Significant improvement in the uniformity of dose distribution was observed. On average, the flatness index of the longitudinal dose distribution from superior to inferior decreases dramatically from 8% for open aperture down to 0.58% for trapezoidal aperture. The results are clinically significant, indicating that delivering the electron arc treatment using a trapezoidal aperture can bring more uniform dose to the patient regardless of the change of patient contour from superior to inferior.

Page generated in 0.0514 seconds