• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 36
  • 2
  • 1
  • Tagged with
  • 41
  • 41
  • 41
  • 37
  • 37
  • 33
  • 20
  • 18
  • 15
  • 15
  • 14
  • 13
  • 13
  • 11
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Uso da angiografia coronária por tomografia computadorizada na avaliação prognóstica de pacientes com suspeita de doença arterial coronária / Coronary computed tomography angiography to evaluate prognosis in patients with suspected coronary artery disease

Márcio Sommer Bittencourt 24 July 2014 (has links)
Introdução: Poucos estudos avaliaram o valor prognóstico em longo prazo da presença, extensão e gravidade da doença arterial coronária (DAC) detectada pela angiotomografia computadorizada de artérias coronárias (TCcor). Métodos: Todos os pacientes consecutivos sem DAC prévia que realizaram TCcor para avaliar DAC foram incluídos. Os resultados da TCcor foram classificados como normal, DAC não-obstrutiva (estenose < 50%), ou obstrutiva (>= 50%). Além disso, com base no número de segmentos com a doença, a DAC foi classificada como não-extensa (<= 4 segmentos) ou extensa (> 4 segmentos). Os pacientes foram acompanhados para o desfecho primário de eventos cardiovasculares (CV) incluindo morte ou infarto do miocárdio (IAM) e um desfecho secundário dos eventos cardiovasculares adversos maiores, constituído por morte CV, IAM ou revascularização coronária tardia (> 90 dias). Resultados: Entre 3242 pacientes acompanhados por uma média de 3,6 ± 1,8 anos, ocorreram 92 (2,8%) eventos primários e 195 (6,0%) apresentaram o desfecho secundário. Em uma análise multivariada, foram associados com aumento de eventos a presença de DAC extensa não-obstrutiva (hazard ratio (HR): 3.1, intervalo de confiança de 95% (IC): 1,5-6,5); não-extensa obstrutiva (HR: 3,0, IC 95%: 1,3 - 7,0) e DAC obstrutiva extensa (HR: 3,9, IC 95%: 2,1-7,2), enquanto os não-extensiva CAD não-obstrutiva não esteve associada a eventos (HR: 1,3, IC 95%: 0,6-2,4). A adição da extensão da placa a um modelo que incluía probabilidade clínica de DAC, assim como a presença e gravidade de DAC resultou na melhoria da predição de eventos CV. Conclusão: Entre os pacientes com DAC não obstrutiva, aqueles com mais de 4 segmentos com doença apresentaram uma maior taxa de CV morte ou MI, comparáveis aos que têm doença obstrutiva com <= 4 segmentos. Mesmo entre os pacientes com DAC obstrutiva, maior extensão de placa esteve associado com maior taxa de eventos. Estes resultados sugerem que, independentemente da presença de estenose, a extensão da placa não-obstrutiva reforça a avaliação de risco além dos dados clínicos e outros achados TCcor / Introduction: There is limited prior data on the long-term prognostic value of the presence, extent and severity of both non-obstructive and obstructive CAD detected by coronary computed tomography angiography (CCTA). Methods: All consecutive patients without prior CAD referred for CCTA to evaluate for CAD were included. CCTA findings were classified as normal, non-obstructive (< 50% stenosis) or obstructive (>= 50%) disease. Additionally, based on the number of segments with disease, extent of CAD was classified as non-extensive (<=4 segments) or extensive (> 4 segments). Patients were followed for a primary endpoint of cardiovascular (CV) death or myocardial infarction (MI) and a secondary endpoint of major adverse cardiovascular events (MACE) consisting of CV death, MI or late coronary revascularization (> 90 days). Results: Among 3242 patients followed for a mean of 3.6±1.8 years, 92 (2.8%) patients who experienced the primary endpoints and 195 (6.0%) experienced the secondary endpoint. In a multivariable analysis, the presence of extensive non-obstructive CAD (hazard ratio (HR): 3.1, 95% confidence interval (CI): 1.5 - 6.5); non-extensive obstructive (HR: 3.0, 95%CI: 1.3 - 7.0) and extensive obstructive CAD (HR: 3.9, 95%CI: 2.1 - 7.2) were associated with increase in the rate of the primary endpoint, while non-extensive non-obstructive CAD was not (HR: 1.3, 95%CI: 0.6 - 2.4). The addition of the extent of plaque to a model, which included clinical probability of CAD as well as the presence and severity of CAD, resulted in improved prediction of all endpoints. Conclusion: Among patients with non-obstructive CAD, those with more than 4 segments with disease experienced a higher rate CV death or MI, comparable to those who have obstructive disease with <= 4 diseased segments. Even among patients with obstructive CAD, greater extent of non-obstructive plaque was associated with higher event rate. These findings suggest that regardless of whether stenosis is present or absent, the extent of non-obstructive plaque enhances risk assessment beyond clinical data and other CCTA findings
12

Avaliação da dose de radiação relacionada ao tempo de chegada do meio de contraste na aorta nas angiotomografias de múltiplos detectores das artérias coronárias / Radiation evaluation related to contrast arrival time in the aorta in multidetector coronary computed tomography angiography

Matsumoto, Jacqueline Kioko Nishimura 11 December 2017 (has links)
Introdução: O uso da tomografia de múltiplos detectores para avaliar a doença arterial coronariana tem aumentado, fornecendo informações valiosas para rotina clínica. O risco potencial da exposição à radiação, por outro lado, exige manter a dose de radiação tão baixo quanto razoavelmente possível. Objetivo: testar e avaliar o ajuste de parâmetros de aquisição no bolus tracking (BT) para reduzir a dose de radiação nos exames de angiotomografias das artérias coronárias (ATCC), sem comprometer a qualidade da imagem. Métodos: Este é um estudo prospectivo de 289 pacientes que realizaram ATCC. Os pacientes foram distribuídos consecutivamente em 4 grupos: A (n = 70), B (n = 79), C (n = 68) e D (n = 72). O grupo A foi o protocolo de referência - recomendado pelo fabricante do tomógrafo. As imagens dos outros grupos foram adquiridas por parâmetros de configuração diferentes do BT, em tempo, para alcançar a redução da dose de radiação. As imagens da fase da angiografia, para todos os grupos, foram realizadas com configurações semelhantes. Foram avaliados parâmetros de qualidade de imagem qualitativa e quantitativamente e a exposição da radiação. Resultados: A dose de radiação do BT foi significativamente diferente entre os grupos, principalmente quando comparados os grupos D e A (p < 0,001), grupos C e A (p < 0,001) e grupos B e A (p < 0,001), com a maior redução no grupo D (redução de 50% em relação ao grupo A). Não houve nenhuma diferença significativa entre os grupos em relação à dose de radiação efetiva e à qualidade de imagem da fase angiográfica. No entanto, a dose de radiação efetiva total (BT + fase angiográfica) foi estatisticamente diferente entre os grupos A e D (p = 0,025). Conclusão: O ajuste do tempo para a aquisição do BT reduz significativamente a dose de radiação efetiva em até 50%, sem reduzir a qualidade da imagem, oferecendo uma nova perspectiva para a redução da radiação total durante a ATCC / Introduction: Modern multidetector computed tomography scanners for assessing coronary artery disease have been growing in use, providing valuable information in clinical routine. The potential risk of radiation exposure, on the other hand, requires keeping radiation dose as low as reasonably achievable. Objectives: Test and evaluate the bolus tracking (BT) acquisition parameters adjustment to reduce radiation dose in coronary computed tomography angiography (CCTA), without compromising image quality. Methods: This is a prospective study of 289 patients referred to CCTA. Patients were consecutively distributed into 4 groups: A (n=70), B (n=79), C (n=68) and D (n=72). Group A was the reference protocol - recommended by the scanner manufacturer. The images of other groups were acquired by setting different time BT parameters in order to achieve radiation dose reduction. The images of angiography phase for all groups were performed with similar settings. Qualitative and quantitative image quality parameters and radiation exposures were evaluated. BT radiation dose was significantly different among groups, mainly when comparing groups D and A (p < 0.001), groups C and A (p < 0.001) and groups B and A (p < 0.001), with the highest reduction in group D (50% reduction in relation to group A). There was no significant difference between groups regarding effective radiation dose for the angiographic phase or image quality. However, total effective radiation dose (BT + angiographic phase) was statistically different between groups A and D (p= 0.025). Conclusion: Time adjustment of BT acquisition significantly reduces effective radiation dose in up to 50%, without reducing image quality, offering a new perspective for total radiation reduction during CCTA
13

Correlação entre escore de Selvester e realce tardio na tomografia computadorizada do coração em portadores de miocardiopatia hipertrófica / Correlation between Selvester QRS score and late enhancement on multidetector computed tomography in patients with hypertrophic cardiomyopathy

Bignoto, Tiago Costa 26 April 2018 (has links)
A Miocardiopatia hipertrófica foi descrita há mais de 50 anos e é a cardiopatia de causa genética mais comum no mundo. Pacientes portadores de miocardiopatia hipertrófica podem apresentar maior risco de eventos arrítmicos graves e morte súbita. Assim torna-se importante o desenvolvimento de técnicas de rastreio desse subgrupo de pacientes para, quando necessário, indicar tratamento específico como o implante de CDI. O realce tardio é a manifestação de fibrose nos exames de imagem como tomografia computadorizada do coração e/ou ressonância cardíaca em pacientes com cardiopatias e quando presente em grandes quantidades, pode estar relacionado a maior incidência de eventos fatais. O eletrocardiograma é ferramenta de baixo custo, não invasiva e difundida nos serviços de saúde brasileiros. O objetivo desse estudo é avaliar a correlação entre a presença e localização de realce tardio na tomografia computadorizada do coração e o achado de fibrose pelo escore de Selvester no eletrocardiograma de repouso de portadores de MCPH, determinar a prevalência de fibrose miocárdica entre os pacientes, comparando a sensibilidade, especificidade, valor preditivo positivo e negativo do escore de Selvester. Foram analisados 112 pacientes do ambulatório de miocardiopatia do Instituto Dante Pazzanese de Cardiologia portadores de miocardiopatia hipertrófica sendo incluídos 75 desses. Foram divididos em dois grupos: Portadores de CDI com 60 pacientes e sem CDI com 15 pacientes. Foram coletados dados clínicos, ecocardiográficos, eletrocardiografia digital e tomografia computadorizada do coração. Foram realizados os cálculos do escore de Selvester e a mensuração e localização de realce tardio nos cortes tomográficos dos pacientes. A correlação dos resultados foi analisada pelo método de regressão linear. As características e frequências mais marcantes do grupo foram sexo masculino 49,4%, idade 41,63 ± 15,16, classe funcional I/II - NYHA 90,6%, fibrilação atrial 21,3%, baixa prevalência de comorbidades como hipertensão arterial 37,3%, diabetes 4%, dislipidemia 17,3%, clearence de creatinina > 60mL/min em 100% e ausência de doença coronariana estabelecida, fração de ejeção do ventrículo esquerdo preservada de 69,9 ± 5,46, medida do septo interventricular de 21,04 ± 6,23 e prevalência de gradiente > 30mmHg na via de saída do ventrículo esquerdo de 37,3%. Dos fatores de risco clássicos, morte súbita familiar e história de síncope eram as mais prevalentes com 57,3% cada, o uso do beta-bloqueador ocorreu em 89,3%. A massa de fibrose pela tomografia computadorizada foi de 9,87 ± 10,79 equivalendo a porcentagem de 5,66 ± 6,16, tendo prevalência em 88% da amostra. Já pelo escore de Selvester, encontramos 8,44 ± 7,39 de porcentagem de fibrose com prevalência de 76%. Na análise de kappa para a variável categórica fibrose entre o escore de Selvester e a tomografia computadorizada do coração, foi encontrada fraca correlação com r = 0,38 (p < 0,01). Enquanto variável contínua aplicando o método de regressão linear, foi encontrada correlação forte com r = 0,7 (p < 0,01). A sensibilidade, especificidade, valor preditivo positivo e valor preditivo negativo do escore de Selvester para o diagnóstico de fibrose foram de, respectivamente, 84,8%, 88,8%, 98,2% e 44,4%. A localização da fibrose apresentou correlação fraca entre os métodos com r = 0,16 (p < 0,01). Os dados desse estudo indicam que há moderada correlação entre o escore de Selvester e o realce tardio pela tomografia computadorizada na quantificação de fibrose em pacientes portadores de miocardiopatia hipertrófica. / Hypertrophic cardiomyopathy is considered the most common genetic cardiovascular disease and has been recognized for 50 years. Patients with hypertrophic cardiomyopathy may present risk of arrhythmic events and sudden cardiac death. Thus, it is important to develop screening techniques for this subgroup of patients to indicate, when necessary, specific treatment as implantable cardioverter defibrillator. Late enhancement is fibrosis manifestation in images exam as multidetector computed tomography and/or magnetic cardiac resonance and if present in large quantities may be related to a higher incidence of fatal events. The electrocardiogram is a low-cost, non-invasive tool that is present in most Brazilian health services. The purpose of this study was to test the presence and location correlation between the Selvester and the late enhancement in the multidetector computed tomography, to determine the prevalence of myocardial fibrosis among patients, comparing the sensitivity, specificity, positive and negative predictive value of the Selvester QRS score. A total of 112 patients from the Institute of Cardiology Dante Pazzanese outpatient clinic with hypertrophic cardiomyopathy were analyzed, and 75 of them were included. They were divided into two groups: ICD patients with 60 patients and no ICD with 15 patients. Clinical, echocardiographic, digital electrocardiography and computed tomography of the heart were collected. The Selvester score was calculated and the measurement and location of late enhancement in the tomographic sections of the patients were performed. The correlation of the results was analyzed by the linear regression. The most remarkable features and frequencies of the group were male gender 49.4%, age 41.63 ± 15.16 years, functional class I / II - NYHA 90.6%, atrial fibrillation 21.3%, low prevalence of comorbidities as hypertension 37.3%, diabetes 4%, dyslipidemia 17.3%, creatinine clearance > 60mL/min in 100% and absence of known coronary artery disease, left ventricular ejection fraction preserved 69.9 ± 5.46, measured of the interventricular septum 21.04 ± 6.23 and prevalence of gradient > 30mmHg in the left ventricular outflow tract 37.3%. Classic risk factors as sudden family death and history of syncope were the most prevalent 57.3% each, the use of beta-blocker occurred in 89.3%. The mass of fibrosis by multidetector computed tomography was 9.87 ± 10.79g, representing a percentage of 5.66 ± 6.16, with a prevalence of 88% of the sample. Selvester QRS score, was found 8.44 ± 7.39 percent of fibrosis with a prevalence of 76%. In the kappa analysis for the categorical variable between the Selvester score and the computed tomography of the heart, we found a weak correlation r = 0.38 (p <0.01), as a continuous variable applying the linear regression, a strong correlation was found r = 0.7 (p <0.01). The sensitivity, specificity, positive predictive value and negative predictive value of the Selvester QRS score for the diagnosis of fibrosis were 84.8%, 88.8%, 98.2% and 44.4%, respectively. The location of the fibrosis showed weak correlation between the methods r = 0.16 (p <0.01). The results of this study indicate there is a moderate correlation between the Selvester QRS score and the late enhancement by multidetector computed tomography in the quantification of fibrosis in patients with hypertrophic cardiomyopathy.
14

Avaliação de medidas lineares para osteotomia tipo Le Fort I por meio de diferentes programas de imagem utilizando a tomografia computadorizada / Assessment of linear measurements for Le Fort I osteotomy with different imaging software using computed tomography

Santos, Bruno Felipe Gaia dos 11 September 2013 (has links)
O sucesso da cirurgia ortognática está relacionado com diversos fatores como análise facial precisa e acurada, e exames de imagem com alta qualidade. Atualmente, diversos programas de imagens tridimensionais, comerciais e abertos, estão disponíveis no auxílio diagnóstico, elaboração do plano de tratamento e simulação do procedimento cirúrgico para correção das deformidades dentofaciais. Entretanto, estudos avaliando os diferentes métodos de mensuração linear empregados pelos programas de imagem por meio da reconstrução 3D no planejamento da osteotomia tipo Le Fort I são escassos e, maiores esclarecimentos sobre sua precisão e a acurácia são necessários. O objetivo deste estudo foi estabelecer: a) precisão e acurácia de medidas lineares tridimensionais para osteotomia tipo Le Fort I obtidas por meio da tomografia computadorizada multislice (TCMS) e feixe cônico (TCFC) e b) comparar a precisão e acurácia de medidas lineares para osteotomia tipo Le Fort I realizadas por meio de três programas de imagem utilizando a 3D-TCFC. A amostra foi constituída por onze crânios secos submetidos à TCMS 64 canais e TCFC. As reconstruções tridimensionais (3D-TC) foram geradas, e medidas lineares (n=11) baseadas em estruturas e pontos anatômicos de interesse à osteotomia tipo Le Fort I foram realizados independentemente, por dois radiologistas experientes, duas vezes cada, utilizando programa Vítrea 3.8.1 em reconstruções 3D-TCMS e 3D-TCFC e os programas OsiriX 1.2 64-bit e Dolphin Imaging versão 11.5.04.35 por meio da 3D-TCFC. Sequencialmente, um terceiro observador experiente e calibrado, que não participou da análise das imagens, realizou as medidas sobre os crânios secos utilizando paquímetro digital (padrão ouro) com quais as medidas foram comparadas. A análise intra e inter-observadores assim como as correlações individuais de cada medida foram realizadas utilizando o coeficiente de correlação intra-classe (CCI), sendo o intervalo de confiança adotado de 95%. Os resultados demonstraram na análise intra-observador, utilizando o programa Vítrea, correlação excelente para todas as medidas variando de 0,87 a 0,96 e 0,82 a 0,98 para os observadores 1 e 2 respectivamente utilizando a TCMS e de 0,84 a 0,98 e 0,80 a 0,98 utilizando a TCFC. A análise inter-observadores variou de 0,85 a 0,98 para a TCMS e de 0,80 a 0,99 para a TCFC. A análise intra-observador utilizando os diferentes programas de imagem na TCFC apresentou variações de 0,90 a 0,97 (Vítrea), 0,65 a 0,97 (OsiriX) e 0,51 a 0,94 (Dolphin). Na análise inter-obsevador obtivemos valores de 0,92 a 0,99 e 0,88 a 0,98 para os observadores 1 e 2 respectivamente utilizando o Vítrea, 0,58 a 0,90 e 0,48 a 0,85 para o programa OsiriX e de 0,80 a 0,96 e 0,57 a 0,92 com o programa Dolphin. O programa Vítrea não apresentou diferenças estatisticamente significante nas análises intra e inter-observador e medidas físicas utilizando a TCMS e TCFC. Em relação à análise dos programas, diferenças estatisticamente foram constatadas com o programa OsiriX e Dolphin em relação ao padrão ouro. / The success of orthognathic surgery depends on many factors as precise and accurate facial analysis and high quality imaging exams. Nowadays a lot of commercial and open-source three-dimensional software programs currently available to assist diagnosis, elaboration of treatment planning, and to predict outcomes related to orthognathic surgery. The aim of this study was to establish: a) the precision and accuracy of three-dimensional linear measurements for Le Fort I osteotomy, obtained from multislice computed tomography (MSCT) and cone-beam computed tomography (CBCT) scans and b) compare the precision and accuracy of linear measurements for Le Fort I osteotomy performed by three different imaging software programs and obtained from 3D-CBCT images. The study population consisted of 11 dried skulls submitted to 64-row MSCT and CBCT scans. Three-dimensional reconstructed images (3D-CT) were generated, and linear measurements (n = 11) based on anatomical structures and landmarks of interest for Le Fort I osteotomy were performed independently by 2 oral and maxillofacial radiologists, twice each, using Vítrea 3.8.1 software for 3D-MSCT and 3D-CBCT and OsiriX 1.2 64-bit and Dolphin Imaging version 11.5.04.35 from 3D-CBCT. Subsequently, a third examiner expert in anatomical analysis and calibrated, who did not evaluate the images, performed measurements on dry skulls using a digital caliper (gold standard) with which the measurements were compared. The analyses of intra- and inter-observer as well as the individual correlations of each measurement were performed using the coefficient of intra-class correlation (ICC), with a confidence interval of 95 %. The intra-observer results showed that using the Vitrea program, excellent correlation for all measurements were reached with ICC values ranging from 0.87 to 0.96 and 0.82 0.98 for observers 1 and 2 respectively using the MSCT and 0.84 to 0.98 and 0.80 to 0.98 using CBCT. Inter-observer analysis ranged from 0.85 to 0.98 for MSCT and 0.80 to 0.99 for CBCT. The intra-observer analysis using the different programs using CBCT images varied from 0.90 to 0.97 for Vitrea, 0.65 to 0.97 for OsiriX and 0.51 to 0.94 using Dolphin. Inter-observer analysis demonstrated values ranging from 0.92 to 0.99 and 0.88 0.98 for observers 1 and 2 respectively using the Vitrea; 0.58 to 0.90 and 0.48 to 0.85 for OsiriX, and 0.80 to 0.96 and 0.57 to 0.92 using Dolphin. Vítrea software showed no statistically significant differences for intra-and inter-observer analysis and physical measurements using MSCT and CBCT. Regarding the analysis of softwares, statistical differences were found with the program OsiriX and Dolphin in comparison to gold standard.
15

Alterações estruturais da face e dos seios paranasais avaliados por tomografia computadorizada multislice em pacientes com leishmaniose mucosa tratada / Facial structure alterations and abnormalities of the paranasal sinuses on multidetector computed tomography scans of patients with treated mucosal leishmaniasis

Camargo, Raphael Abegão de 10 February 2014 (has links)
Introdução: No Brasil, a leishmaniose tegumentar americana (LTA) é uma importante antropozoonose endêmica na maioria das regiões do país. Apesar da expansão da doença nos últimos anos, a LTA continua a ser uma doença negligenciada. A leishmaniose mucosa (LM) tem como principal agente causador a Leishmania (V.) brasilienses, e habitualmente ocorre meses ou anos após a infecção cutânea sintomática ou assintomática. Aproximadamente 5% dos pacientes com leishmaniose cutânea não tratada adequadamente irão desenvolver a LM, forma que causa importante morbidade aos pacientes. A LM é uma doença progressiva, que acomete cartilagens e estruturas ósseas da face, faringe e laringe. Complicações associadas à leishmaniose mucosa já foram descritas, embora não existam estudos que avaliem as alterações estruturais da face e seios paranasais utilizando métodos radiológicos e que estimem a prevalência de sinusopatia nesta população ou que a compare com a população geral. Objetivo: Avaliar o grau de opacificação dos seios paranasais em pacientes com leishmaniose mucosa tratada, assim como eventuais alterações anatômicas na face associadas à LM, através de tomografia computadorizada multislice (TCM) dos seios paranasais e comparar os achados encontrados nesta população com um grupo controle formado por pacientes que realizaram TCM de órbita. Este estudo também tem o escopo de determinar a prevalência de sinusopatia crônica nos pacientes com LM pós-tratamento, bem como encontrar prováveis variáveis preditoras que possam estar relacionadas com a gravidade da sinusopatia e das alterações tomográficas encontradas. Métodos: Foram avaliados 54 pacientes com LM tratada, que foram submetidos à TCM dos seios da face, e comparados com grupo controle de 40 pacientes que realizaram TCM de órbita. A análise das tomografias foi realizada a partir de reconstruções multiplanares nos planos axial, coronal e sagital. Foram avaliados o grau de opacificação (sinusopatia) dos seios paranasais, bem como a existência de eventuais alterações na face que pudessem estar relacionadas à LM. O grau de sinusopatia foi estabelecido seguindo-se os critérios de Lund-Mackay, segundo os quais foram atribuídos um valor para o grau de opacificação de cada sistema sinusal e dos complexos ostiomeatais, comparando o score dos casos com o dos controles. Posteriormente foi realizada uma análise comparativa entre os pacientes do grupo leishmaniose mucosa, que foram divididos em dois subgrupos, de acordo com a presença (Lund-Mackay >= 4) ou ausência (Lund-Mackay < 4) de doença sinusal, sendo 40 e 14 pacientes respectivamente. Após esta divisão foram feitas análises univariadas exploratórias em busca de variáveis preditoras que pudessem estar associadas com uma maior gravidade de sinusopatia apresentada. O nível de significância foi estabelecido com p<0,05. Resultados: Quarenta dos 54 pacientes com antecedente de LM (74,1%) apresentaram score tomográfico compatível com sinusopatia crônica (Lund-Mackay >= 4). Os pacientes do grupo leishmaniose mucosa apresentaram maior score de Lund-Mackay que os pacientes do grupo controle, bem como maior número de alterações na TCM dos seios paranasais, provavelmente associadas à leishmaniose. Estes pacientes também apresentaram graus mais severos de opacificação parcial e espessamento mucoso pansinusal 23/54 (42.6%). Além disso, opacificação total de pelo menos um dos seios paranasais só foi observada nos pacientes do grupo leishmaniose mucosa. Os pacientes com leishmaniose com score de Lund-Mackay >= 4 apresentaram maior tempo de sintomas até o primeiro tratamento e doença mais grave no momento do diagnóstico, sendo portanto prováveis variáveis preditoras de gravidade da sinusopatia. Conclusão: As tomografias computadorizadas dos seios paranasais dos pacientes com LM apresentaram diversas alterações estruturais, demonstrando o poder destrutivo desta doença. A alta prevalência de sinusite crônica observada nas tomografias computadorizadas desses pacientes quando comparados ao grupo controle, sugere que a LM pode ser um fator de risco para o desenvolvimento de sinusite crônica nesta população. Sexo masculino, tempo de sintomas até o primeiro tratamento e gravidade da LM no momento do diagnóstico podem ser consideradas prováveis variáveis preditoras de sinusite crônica nesses pacientes / Introduction: American tegumentary leishmaniasis (ATL) is an important anthropozoonosis that is endemic in most regions in Brazil. Despite the spread of the disease in recent years, ATL remains a neglected disease. Mucosal leishmaniasis (ML) is mainly caused by Leishmania (V.) brasiliensis agent, and usually occurs months or years after symptomatic or asymptomatic skin infection. Approximately 5% of patients with untreated cutaneous leishmaniasis will develop ML, a presentation that causes significant morbidity to patients. The mucosal leishmaniasis is a progressive disease that affects cartilage and bone structures of the nose and paranasal sinuses as well as other upper respiratory tract structures. Complications associated with ML have been described, but there is a lack of studies which evaluate the structural changes of the nose and paranasal sinuses in ML using radiological methods. Objective: To assess the degree of opacification of the paranasal sinuses in patients with treated mucosal leishmaniasis as well as any anatomic changes in the face associated with ML through multidector computed tomography scans (MDCT) of the sinuses, and compare the findings in this population with a control group. This study also aims at determining the prevalence of chronic sinusitis in patients with treated ML as well as finding probable predictive variables that may be related to the severity of sinus disease and CT findings. Methods: We evaluated 54 patients with treated ML who were submitted to MDCT of the sinuses, and compared with a control group of 40 patients who underwent MDCT of orbit. Analysis of the scans was performed from multiplanar reconstructions in the axial, coronal and sagittal views. The degree of sinus disease was assessed according to the Lund-Mackay criteria, in which a value was assigned to the degree of opacification of each sinus system and ostiomeatal complexes, and the scores from the mucosal leishmaniasis group were compared to the control group. A comparative analysis was then performed among patients in the mucosal leishmaniasis group, who were divided into 2 subgroups according to the presence (Lund-Mackay >= 4) or absence (Lund-Mackay < 4) of sinus disease, with 40 and 14 patients respectively. Following this subdivision, exploratory univariate analysis were performed to identify predictive variables that could be associated to the presentation of greater severity of sinus disease. The level of significance was defined as p <0.05. Results: Forty of the 54 patients with a history of ML (74.1%) had a tomographic score compatible with chronic sinusitis (Lund- Mackay >= 4). CT scans in the leishmaniasis and control groups demonstrated significant differences in terms of facial structural alterations. Patients from the mucosal leishmaniasis group showed more severe levels of partial opacification and pan sinus mucosal thickening 23/54 (42.6%), furthermore complete opacification of at least one paranasal sinus was only observed in the leismaniasis group. Patients from the mucosal leishmaniasis group with Lund-Mackay score >= 4 presented greater length of symptoms before treatment and more severe presentation of the disease at the diagnosis. Conclusion: CT scans of the sinus of patients with ML also presented several structural alterations, expressing the prominent destructive feature of the disease. The higher prevalence of chronic rhinosinusitis observed in CT scans of patients with treated ML in this study when compared to the control group suggests that ML can be seen as a risk factor for chronic rhinosinusitis in this population. Male sex, having the disease for more than two years before first treatment and/or a more severe presentation of ML at diagnosis, can be considered as predictive variables of chronic sinusitis in these patients
16

Alterações estruturais da face e dos seios paranasais avaliados por tomografia computadorizada multislice em pacientes com leishmaniose mucosa tratada / Facial structure alterations and abnormalities of the paranasal sinuses on multidetector computed tomography scans of patients with treated mucosal leishmaniasis

Raphael Abegão de Camargo 10 February 2014 (has links)
Introdução: No Brasil, a leishmaniose tegumentar americana (LTA) é uma importante antropozoonose endêmica na maioria das regiões do país. Apesar da expansão da doença nos últimos anos, a LTA continua a ser uma doença negligenciada. A leishmaniose mucosa (LM) tem como principal agente causador a Leishmania (V.) brasilienses, e habitualmente ocorre meses ou anos após a infecção cutânea sintomática ou assintomática. Aproximadamente 5% dos pacientes com leishmaniose cutânea não tratada adequadamente irão desenvolver a LM, forma que causa importante morbidade aos pacientes. A LM é uma doença progressiva, que acomete cartilagens e estruturas ósseas da face, faringe e laringe. Complicações associadas à leishmaniose mucosa já foram descritas, embora não existam estudos que avaliem as alterações estruturais da face e seios paranasais utilizando métodos radiológicos e que estimem a prevalência de sinusopatia nesta população ou que a compare com a população geral. Objetivo: Avaliar o grau de opacificação dos seios paranasais em pacientes com leishmaniose mucosa tratada, assim como eventuais alterações anatômicas na face associadas à LM, através de tomografia computadorizada multislice (TCM) dos seios paranasais e comparar os achados encontrados nesta população com um grupo controle formado por pacientes que realizaram TCM de órbita. Este estudo também tem o escopo de determinar a prevalência de sinusopatia crônica nos pacientes com LM pós-tratamento, bem como encontrar prováveis variáveis preditoras que possam estar relacionadas com a gravidade da sinusopatia e das alterações tomográficas encontradas. Métodos: Foram avaliados 54 pacientes com LM tratada, que foram submetidos à TCM dos seios da face, e comparados com grupo controle de 40 pacientes que realizaram TCM de órbita. A análise das tomografias foi realizada a partir de reconstruções multiplanares nos planos axial, coronal e sagital. Foram avaliados o grau de opacificação (sinusopatia) dos seios paranasais, bem como a existência de eventuais alterações na face que pudessem estar relacionadas à LM. O grau de sinusopatia foi estabelecido seguindo-se os critérios de Lund-Mackay, segundo os quais foram atribuídos um valor para o grau de opacificação de cada sistema sinusal e dos complexos ostiomeatais, comparando o score dos casos com o dos controles. Posteriormente foi realizada uma análise comparativa entre os pacientes do grupo leishmaniose mucosa, que foram divididos em dois subgrupos, de acordo com a presença (Lund-Mackay >= 4) ou ausência (Lund-Mackay < 4) de doença sinusal, sendo 40 e 14 pacientes respectivamente. Após esta divisão foram feitas análises univariadas exploratórias em busca de variáveis preditoras que pudessem estar associadas com uma maior gravidade de sinusopatia apresentada. O nível de significância foi estabelecido com p<0,05. Resultados: Quarenta dos 54 pacientes com antecedente de LM (74,1%) apresentaram score tomográfico compatível com sinusopatia crônica (Lund-Mackay >= 4). Os pacientes do grupo leishmaniose mucosa apresentaram maior score de Lund-Mackay que os pacientes do grupo controle, bem como maior número de alterações na TCM dos seios paranasais, provavelmente associadas à leishmaniose. Estes pacientes também apresentaram graus mais severos de opacificação parcial e espessamento mucoso pansinusal 23/54 (42.6%). Além disso, opacificação total de pelo menos um dos seios paranasais só foi observada nos pacientes do grupo leishmaniose mucosa. Os pacientes com leishmaniose com score de Lund-Mackay >= 4 apresentaram maior tempo de sintomas até o primeiro tratamento e doença mais grave no momento do diagnóstico, sendo portanto prováveis variáveis preditoras de gravidade da sinusopatia. Conclusão: As tomografias computadorizadas dos seios paranasais dos pacientes com LM apresentaram diversas alterações estruturais, demonstrando o poder destrutivo desta doença. A alta prevalência de sinusite crônica observada nas tomografias computadorizadas desses pacientes quando comparados ao grupo controle, sugere que a LM pode ser um fator de risco para o desenvolvimento de sinusite crônica nesta população. Sexo masculino, tempo de sintomas até o primeiro tratamento e gravidade da LM no momento do diagnóstico podem ser consideradas prováveis variáveis preditoras de sinusite crônica nesses pacientes / Introduction: American tegumentary leishmaniasis (ATL) is an important anthropozoonosis that is endemic in most regions in Brazil. Despite the spread of the disease in recent years, ATL remains a neglected disease. Mucosal leishmaniasis (ML) is mainly caused by Leishmania (V.) brasiliensis agent, and usually occurs months or years after symptomatic or asymptomatic skin infection. Approximately 5% of patients with untreated cutaneous leishmaniasis will develop ML, a presentation that causes significant morbidity to patients. The mucosal leishmaniasis is a progressive disease that affects cartilage and bone structures of the nose and paranasal sinuses as well as other upper respiratory tract structures. Complications associated with ML have been described, but there is a lack of studies which evaluate the structural changes of the nose and paranasal sinuses in ML using radiological methods. Objective: To assess the degree of opacification of the paranasal sinuses in patients with treated mucosal leishmaniasis as well as any anatomic changes in the face associated with ML through multidector computed tomography scans (MDCT) of the sinuses, and compare the findings in this population with a control group. This study also aims at determining the prevalence of chronic sinusitis in patients with treated ML as well as finding probable predictive variables that may be related to the severity of sinus disease and CT findings. Methods: We evaluated 54 patients with treated ML who were submitted to MDCT of the sinuses, and compared with a control group of 40 patients who underwent MDCT of orbit. Analysis of the scans was performed from multiplanar reconstructions in the axial, coronal and sagittal views. The degree of sinus disease was assessed according to the Lund-Mackay criteria, in which a value was assigned to the degree of opacification of each sinus system and ostiomeatal complexes, and the scores from the mucosal leishmaniasis group were compared to the control group. A comparative analysis was then performed among patients in the mucosal leishmaniasis group, who were divided into 2 subgroups according to the presence (Lund-Mackay >= 4) or absence (Lund-Mackay < 4) of sinus disease, with 40 and 14 patients respectively. Following this subdivision, exploratory univariate analysis were performed to identify predictive variables that could be associated to the presentation of greater severity of sinus disease. The level of significance was defined as p <0.05. Results: Forty of the 54 patients with a history of ML (74.1%) had a tomographic score compatible with chronic sinusitis (Lund- Mackay >= 4). CT scans in the leishmaniasis and control groups demonstrated significant differences in terms of facial structural alterations. Patients from the mucosal leishmaniasis group showed more severe levels of partial opacification and pan sinus mucosal thickening 23/54 (42.6%), furthermore complete opacification of at least one paranasal sinus was only observed in the leismaniasis group. Patients from the mucosal leishmaniasis group with Lund-Mackay score >= 4 presented greater length of symptoms before treatment and more severe presentation of the disease at the diagnosis. Conclusion: CT scans of the sinus of patients with ML also presented several structural alterations, expressing the prominent destructive feature of the disease. The higher prevalence of chronic rhinosinusitis observed in CT scans of patients with treated ML in this study when compared to the control group suggests that ML can be seen as a risk factor for chronic rhinosinusitis in this population. Male sex, having the disease for more than two years before first treatment and/or a more severe presentation of ML at diagnosis, can be considered as predictive variables of chronic sinusitis in these patients
17

Avaliação da dose de radiação relacionada ao tempo de chegada do meio de contraste na aorta nas angiotomografias de múltiplos detectores das artérias coronárias / Radiation evaluation related to contrast arrival time in the aorta in multidetector coronary computed tomography angiography

Jacqueline Kioko Nishimura Matsumoto 11 December 2017 (has links)
Introdução: O uso da tomografia de múltiplos detectores para avaliar a doença arterial coronariana tem aumentado, fornecendo informações valiosas para rotina clínica. O risco potencial da exposição à radiação, por outro lado, exige manter a dose de radiação tão baixo quanto razoavelmente possível. Objetivo: testar e avaliar o ajuste de parâmetros de aquisição no bolus tracking (BT) para reduzir a dose de radiação nos exames de angiotomografias das artérias coronárias (ATCC), sem comprometer a qualidade da imagem. Métodos: Este é um estudo prospectivo de 289 pacientes que realizaram ATCC. Os pacientes foram distribuídos consecutivamente em 4 grupos: A (n = 70), B (n = 79), C (n = 68) e D (n = 72). O grupo A foi o protocolo de referência - recomendado pelo fabricante do tomógrafo. As imagens dos outros grupos foram adquiridas por parâmetros de configuração diferentes do BT, em tempo, para alcançar a redução da dose de radiação. As imagens da fase da angiografia, para todos os grupos, foram realizadas com configurações semelhantes. Foram avaliados parâmetros de qualidade de imagem qualitativa e quantitativamente e a exposição da radiação. Resultados: A dose de radiação do BT foi significativamente diferente entre os grupos, principalmente quando comparados os grupos D e A (p < 0,001), grupos C e A (p < 0,001) e grupos B e A (p < 0,001), com a maior redução no grupo D (redução de 50% em relação ao grupo A). Não houve nenhuma diferença significativa entre os grupos em relação à dose de radiação efetiva e à qualidade de imagem da fase angiográfica. No entanto, a dose de radiação efetiva total (BT + fase angiográfica) foi estatisticamente diferente entre os grupos A e D (p = 0,025). Conclusão: O ajuste do tempo para a aquisição do BT reduz significativamente a dose de radiação efetiva em até 50%, sem reduzir a qualidade da imagem, oferecendo uma nova perspectiva para a redução da radiação total durante a ATCC / Introduction: Modern multidetector computed tomography scanners for assessing coronary artery disease have been growing in use, providing valuable information in clinical routine. The potential risk of radiation exposure, on the other hand, requires keeping radiation dose as low as reasonably achievable. Objectives: Test and evaluate the bolus tracking (BT) acquisition parameters adjustment to reduce radiation dose in coronary computed tomography angiography (CCTA), without compromising image quality. Methods: This is a prospective study of 289 patients referred to CCTA. Patients were consecutively distributed into 4 groups: A (n=70), B (n=79), C (n=68) and D (n=72). Group A was the reference protocol - recommended by the scanner manufacturer. The images of other groups were acquired by setting different time BT parameters in order to achieve radiation dose reduction. The images of angiography phase for all groups were performed with similar settings. Qualitative and quantitative image quality parameters and radiation exposures were evaluated. BT radiation dose was significantly different among groups, mainly when comparing groups D and A (p < 0.001), groups C and A (p < 0.001) and groups B and A (p < 0.001), with the highest reduction in group D (50% reduction in relation to group A). There was no significant difference between groups regarding effective radiation dose for the angiographic phase or image quality. However, total effective radiation dose (BT + angiographic phase) was statistically different between groups A and D (p= 0.025). Conclusion: Time adjustment of BT acquisition significantly reduces effective radiation dose in up to 50%, without reducing image quality, offering a new perspective for total radiation reduction during CCTA
18

Avaliação de medidas lineares para osteotomia tipo Le Fort I por meio de diferentes programas de imagem utilizando a tomografia computadorizada / Assessment of linear measurements for Le Fort I osteotomy with different imaging software using computed tomography

Bruno Felipe Gaia dos Santos 11 September 2013 (has links)
O sucesso da cirurgia ortognática está relacionado com diversos fatores como análise facial precisa e acurada, e exames de imagem com alta qualidade. Atualmente, diversos programas de imagens tridimensionais, comerciais e abertos, estão disponíveis no auxílio diagnóstico, elaboração do plano de tratamento e simulação do procedimento cirúrgico para correção das deformidades dentofaciais. Entretanto, estudos avaliando os diferentes métodos de mensuração linear empregados pelos programas de imagem por meio da reconstrução 3D no planejamento da osteotomia tipo Le Fort I são escassos e, maiores esclarecimentos sobre sua precisão e a acurácia são necessários. O objetivo deste estudo foi estabelecer: a) precisão e acurácia de medidas lineares tridimensionais para osteotomia tipo Le Fort I obtidas por meio da tomografia computadorizada multislice (TCMS) e feixe cônico (TCFC) e b) comparar a precisão e acurácia de medidas lineares para osteotomia tipo Le Fort I realizadas por meio de três programas de imagem utilizando a 3D-TCFC. A amostra foi constituída por onze crânios secos submetidos à TCMS 64 canais e TCFC. As reconstruções tridimensionais (3D-TC) foram geradas, e medidas lineares (n=11) baseadas em estruturas e pontos anatômicos de interesse à osteotomia tipo Le Fort I foram realizados independentemente, por dois radiologistas experientes, duas vezes cada, utilizando programa Vítrea 3.8.1 em reconstruções 3D-TCMS e 3D-TCFC e os programas OsiriX 1.2 64-bit e Dolphin Imaging versão 11.5.04.35 por meio da 3D-TCFC. Sequencialmente, um terceiro observador experiente e calibrado, que não participou da análise das imagens, realizou as medidas sobre os crânios secos utilizando paquímetro digital (padrão ouro) com quais as medidas foram comparadas. A análise intra e inter-observadores assim como as correlações individuais de cada medida foram realizadas utilizando o coeficiente de correlação intra-classe (CCI), sendo o intervalo de confiança adotado de 95%. Os resultados demonstraram na análise intra-observador, utilizando o programa Vítrea, correlação excelente para todas as medidas variando de 0,87 a 0,96 e 0,82 a 0,98 para os observadores 1 e 2 respectivamente utilizando a TCMS e de 0,84 a 0,98 e 0,80 a 0,98 utilizando a TCFC. A análise inter-observadores variou de 0,85 a 0,98 para a TCMS e de 0,80 a 0,99 para a TCFC. A análise intra-observador utilizando os diferentes programas de imagem na TCFC apresentou variações de 0,90 a 0,97 (Vítrea), 0,65 a 0,97 (OsiriX) e 0,51 a 0,94 (Dolphin). Na análise inter-obsevador obtivemos valores de 0,92 a 0,99 e 0,88 a 0,98 para os observadores 1 e 2 respectivamente utilizando o Vítrea, 0,58 a 0,90 e 0,48 a 0,85 para o programa OsiriX e de 0,80 a 0,96 e 0,57 a 0,92 com o programa Dolphin. O programa Vítrea não apresentou diferenças estatisticamente significante nas análises intra e inter-observador e medidas físicas utilizando a TCMS e TCFC. Em relação à análise dos programas, diferenças estatisticamente foram constatadas com o programa OsiriX e Dolphin em relação ao padrão ouro. / The success of orthognathic surgery depends on many factors as precise and accurate facial analysis and high quality imaging exams. Nowadays a lot of commercial and open-source three-dimensional software programs currently available to assist diagnosis, elaboration of treatment planning, and to predict outcomes related to orthognathic surgery. The aim of this study was to establish: a) the precision and accuracy of three-dimensional linear measurements for Le Fort I osteotomy, obtained from multislice computed tomography (MSCT) and cone-beam computed tomography (CBCT) scans and b) compare the precision and accuracy of linear measurements for Le Fort I osteotomy performed by three different imaging software programs and obtained from 3D-CBCT images. The study population consisted of 11 dried skulls submitted to 64-row MSCT and CBCT scans. Three-dimensional reconstructed images (3D-CT) were generated, and linear measurements (n = 11) based on anatomical structures and landmarks of interest for Le Fort I osteotomy were performed independently by 2 oral and maxillofacial radiologists, twice each, using Vítrea 3.8.1 software for 3D-MSCT and 3D-CBCT and OsiriX 1.2 64-bit and Dolphin Imaging version 11.5.04.35 from 3D-CBCT. Subsequently, a third examiner expert in anatomical analysis and calibrated, who did not evaluate the images, performed measurements on dry skulls using a digital caliper (gold standard) with which the measurements were compared. The analyses of intra- and inter-observer as well as the individual correlations of each measurement were performed using the coefficient of intra-class correlation (ICC), with a confidence interval of 95 %. The intra-observer results showed that using the Vitrea program, excellent correlation for all measurements were reached with ICC values ranging from 0.87 to 0.96 and 0.82 0.98 for observers 1 and 2 respectively using the MSCT and 0.84 to 0.98 and 0.80 to 0.98 using CBCT. Inter-observer analysis ranged from 0.85 to 0.98 for MSCT and 0.80 to 0.99 for CBCT. The intra-observer analysis using the different programs using CBCT images varied from 0.90 to 0.97 for Vitrea, 0.65 to 0.97 for OsiriX and 0.51 to 0.94 using Dolphin. Inter-observer analysis demonstrated values ranging from 0.92 to 0.99 and 0.88 0.98 for observers 1 and 2 respectively using the Vitrea; 0.58 to 0.90 and 0.48 to 0.85 for OsiriX, and 0.80 to 0.96 and 0.57 to 0.92 using Dolphin. Vítrea software showed no statistically significant differences for intra-and inter-observer analysis and physical measurements using MSCT and CBCT. Regarding the analysis of softwares, statistical differences were found with the program OsiriX and Dolphin in comparison to gold standard.
19

Aterosclerose coronária em indivíduos assintomáticos com deficiência do hormônio do crescimento / Prevalence of subclinical coronary atherosclerosis in asymptomatic individuals with growth hormone deficiency

Burgos, Ursula Maria Moreira Costa 20 February 2016 (has links)
GH and its principal mediator IGF-I have important effects on metabolic and cardiovascular (CV) status. While acquired GH deficiency (GHD) is often associated to increased CV risk, the consequences of congenital GHD are not known. We have described a large group of patients with isolated GHD (IGHD) due to a homozygous mutation (c.57+1G>A) in the GH releasing hormone receptor gene, and shown that adult GH-naïve individuals have no evidence of clinically evident premature atherosclerosis. To test weather subclinical atherosclerosis is anticipated in untreated IGHD, we ruled a cross-sectional study of 25 IGHD and27 adult controls matched for age and gender. A comprehensive clinical and biochemical panel and coronary artery calcium scores by multi-detector tomography were evaluated. Height, weight, IGF-I, homeostasis model assessment of insulin resistance, creatinine and creatinokinase were lower in IGHD group. Median and interquartile range of calcium scores distribution was similar in the two groups: IGHD 0 (0) and control 0 (4.9). The vast majority of the calcium scores [20 of 25 IGHD (80%) and 18 of 27 controls (66.6%)] were equal to zero (difference not significant). There was no difference in the calcium scores classification. None of IGHD subjects had minimal calcification, which were present in 4 controls. Three IGHD and four controls had mild calcification. There were two IGHD individuals with moderate calcification and one control with severe calcification. Our study provides evidence that subjects with congenital isolated lifetime and untreated severe IGHD do not have accelerated subclinical coronary atherosclerosis. / O GH e seu principal mediador IGF-I têm importantes efeitos no perfil metabólico e cardiovascular (CV). Enquanto a deficiência adquirida do hormônio do crescimento (DGH) está frequentemente associada ao aumento no risco CV, as consequências da deficiência congênita não são conhecidas. Descrevemos um grande grupo de pacientes com deficiência isolada de hormônio do crescimento (DIGH) secundária a mutação homozigótica (c.57+1G>A) no gene do receptor do hormônio liberador do GH, e mostramos que indivíduos adultos depletados de GH não têm evidência de aterosclerose prematura clinicamente manifesta. Para testar se a aterosclerose subclínica se antecipa na DIGH não tratada, realizamos um estudo transversal com 25 portadores de DIGH e 27 controles adultos pareados por sexo e idade. Características clínicas e bioquímicas e escore de cálcio (EC) coronário pela tomografia computadorizada por múltiplos detectores, foram avaliados. Altura, peso, IGF-I, modelo de homeostase de avaliação da resistência a insulina (HOMAIR), creatinina e creatinoquinase foram menores no grupo DIGH. Mediana e intervalo interquartis da distribuição do EC foram similares entre os dois grupos: DIGH 0(0) e controles 0 (4.9). A vasta maioria dos EC [20 de 25 DIGH (80%) e 18 de 27 controles (66.6%)] foi igual a zero (diferença não significativa). Não houve diferença na classificação de EC. Nenhum dos indivíduos portadores de DIGH apresentou calcificação mínima, a qual estava presente em 4 controles. Três portadores de DIGH e 4 controles tinham calcificação leve. Dois portadores de DIGH com moderada calcificação e 1 controle com calcificação severa. Nosso estudo fornece evidências de que indivíduos com DIGH congênita, isolada, vitalícia e não tratada não têm aterosclerose coronariana subclínica precoce.
20

Correlação entre escore de Selvester e realce tardio na tomografia computadorizada do coração em portadores de miocardiopatia hipertrófica / Correlation between Selvester QRS score and late enhancement on multidetector computed tomography in patients with hypertrophic cardiomyopathy

Tiago Costa Bignoto 26 April 2018 (has links)
A Miocardiopatia hipertrófica foi descrita há mais de 50 anos e é a cardiopatia de causa genética mais comum no mundo. Pacientes portadores de miocardiopatia hipertrófica podem apresentar maior risco de eventos arrítmicos graves e morte súbita. Assim torna-se importante o desenvolvimento de técnicas de rastreio desse subgrupo de pacientes para, quando necessário, indicar tratamento específico como o implante de CDI. O realce tardio é a manifestação de fibrose nos exames de imagem como tomografia computadorizada do coração e/ou ressonância cardíaca em pacientes com cardiopatias e quando presente em grandes quantidades, pode estar relacionado a maior incidência de eventos fatais. O eletrocardiograma é ferramenta de baixo custo, não invasiva e difundida nos serviços de saúde brasileiros. O objetivo desse estudo é avaliar a correlação entre a presença e localização de realce tardio na tomografia computadorizada do coração e o achado de fibrose pelo escore de Selvester no eletrocardiograma de repouso de portadores de MCPH, determinar a prevalência de fibrose miocárdica entre os pacientes, comparando a sensibilidade, especificidade, valor preditivo positivo e negativo do escore de Selvester. Foram analisados 112 pacientes do ambulatório de miocardiopatia do Instituto Dante Pazzanese de Cardiologia portadores de miocardiopatia hipertrófica sendo incluídos 75 desses. Foram divididos em dois grupos: Portadores de CDI com 60 pacientes e sem CDI com 15 pacientes. Foram coletados dados clínicos, ecocardiográficos, eletrocardiografia digital e tomografia computadorizada do coração. Foram realizados os cálculos do escore de Selvester e a mensuração e localização de realce tardio nos cortes tomográficos dos pacientes. A correlação dos resultados foi analisada pelo método de regressão linear. As características e frequências mais marcantes do grupo foram sexo masculino 49,4%, idade 41,63 ± 15,16, classe funcional I/II - NYHA 90,6%, fibrilação atrial 21,3%, baixa prevalência de comorbidades como hipertensão arterial 37,3%, diabetes 4%, dislipidemia 17,3%, clearence de creatinina > 60mL/min em 100% e ausência de doença coronariana estabelecida, fração de ejeção do ventrículo esquerdo preservada de 69,9 ± 5,46, medida do septo interventricular de 21,04 ± 6,23 e prevalência de gradiente > 30mmHg na via de saída do ventrículo esquerdo de 37,3%. Dos fatores de risco clássicos, morte súbita familiar e história de síncope eram as mais prevalentes com 57,3% cada, o uso do beta-bloqueador ocorreu em 89,3%. A massa de fibrose pela tomografia computadorizada foi de 9,87 ± 10,79 equivalendo a porcentagem de 5,66 ± 6,16, tendo prevalência em 88% da amostra. Já pelo escore de Selvester, encontramos 8,44 ± 7,39 de porcentagem de fibrose com prevalência de 76%. Na análise de kappa para a variável categórica fibrose entre o escore de Selvester e a tomografia computadorizada do coração, foi encontrada fraca correlação com r = 0,38 (p < 0,01). Enquanto variável contínua aplicando o método de regressão linear, foi encontrada correlação forte com r = 0,7 (p < 0,01). A sensibilidade, especificidade, valor preditivo positivo e valor preditivo negativo do escore de Selvester para o diagnóstico de fibrose foram de, respectivamente, 84,8%, 88,8%, 98,2% e 44,4%. A localização da fibrose apresentou correlação fraca entre os métodos com r = 0,16 (p < 0,01). Os dados desse estudo indicam que há moderada correlação entre o escore de Selvester e o realce tardio pela tomografia computadorizada na quantificação de fibrose em pacientes portadores de miocardiopatia hipertrófica. / Hypertrophic cardiomyopathy is considered the most common genetic cardiovascular disease and has been recognized for 50 years. Patients with hypertrophic cardiomyopathy may present risk of arrhythmic events and sudden cardiac death. Thus, it is important to develop screening techniques for this subgroup of patients to indicate, when necessary, specific treatment as implantable cardioverter defibrillator. Late enhancement is fibrosis manifestation in images exam as multidetector computed tomography and/or magnetic cardiac resonance and if present in large quantities may be related to a higher incidence of fatal events. The electrocardiogram is a low-cost, non-invasive tool that is present in most Brazilian health services. The purpose of this study was to test the presence and location correlation between the Selvester and the late enhancement in the multidetector computed tomography, to determine the prevalence of myocardial fibrosis among patients, comparing the sensitivity, specificity, positive and negative predictive value of the Selvester QRS score. A total of 112 patients from the Institute of Cardiology Dante Pazzanese outpatient clinic with hypertrophic cardiomyopathy were analyzed, and 75 of them were included. They were divided into two groups: ICD patients with 60 patients and no ICD with 15 patients. Clinical, echocardiographic, digital electrocardiography and computed tomography of the heart were collected. The Selvester score was calculated and the measurement and location of late enhancement in the tomographic sections of the patients were performed. The correlation of the results was analyzed by the linear regression. The most remarkable features and frequencies of the group were male gender 49.4%, age 41.63 ± 15.16 years, functional class I / II - NYHA 90.6%, atrial fibrillation 21.3%, low prevalence of comorbidities as hypertension 37.3%, diabetes 4%, dyslipidemia 17.3%, creatinine clearance > 60mL/min in 100% and absence of known coronary artery disease, left ventricular ejection fraction preserved 69.9 ± 5.46, measured of the interventricular septum 21.04 ± 6.23 and prevalence of gradient > 30mmHg in the left ventricular outflow tract 37.3%. Classic risk factors as sudden family death and history of syncope were the most prevalent 57.3% each, the use of beta-blocker occurred in 89.3%. The mass of fibrosis by multidetector computed tomography was 9.87 ± 10.79g, representing a percentage of 5.66 ± 6.16, with a prevalence of 88% of the sample. Selvester QRS score, was found 8.44 ± 7.39 percent of fibrosis with a prevalence of 76%. In the kappa analysis for the categorical variable between the Selvester score and the computed tomography of the heart, we found a weak correlation r = 0.38 (p <0.01), as a continuous variable applying the linear regression, a strong correlation was found r = 0.7 (p <0.01). The sensitivity, specificity, positive predictive value and negative predictive value of the Selvester QRS score for the diagnosis of fibrosis were 84.8%, 88.8%, 98.2% and 44.4%, respectively. The location of the fibrosis showed weak correlation between the methods r = 0.16 (p <0.01). The results of this study indicate there is a moderate correlation between the Selvester QRS score and the late enhancement by multidetector computed tomography in the quantification of fibrosis in patients with hypertrophic cardiomyopathy.

Page generated in 0.1332 seconds