• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • 1
  • Tagged with
  • 5
  • 5
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Dépollution de l'habitacle automobile par photocatalyse et catalyse d'oxydation à froid / Cleaning the Vehicle Cabin Air by Photocatalysis and Room-Temperature Oxidation Catalysis

Bouhatmi, Marième 25 March 2019 (has links)
L’automobile étant le premier moyen de déplacement en France, la présence de Composés Organiques Volatils (COVs) et de monoxyde de carbone à l’intérieur de l’habitacle, constitue un problème de santé publique. Plusieurs systèmes de dépollution, basés sur des méthodes d'adsorption, existent sur le marché, mais ne permettent qu'une simple rétention des COVs en surface. Parallèlement, des méthodes moins conventionnelles telle que la photocatalyse utilisant le dioxyde de titane, permettent d'oxyder les COVs sous irradiation, en présence d'humidité et à température ambiante. Cependant, la photocatalyse ne permet pas l’oxydation de certains polluants comme le monoxyde de carbone sans ajout de co-catalyseur. Pour éliminer le CO, la catalyse d’oxydation à froid sur dioxyde de manganèse a été étudiée.L’objectif de cette thèse est de développer une solution économique permettant la dépollution de l’habitacle automobile. Ce projet vise à allier à terme l’oxydation photocatalytique d’un COV modèle le n-pentane sur TiO2 P25 et l’oxydation catalytique du monoxyde de carbone à température ambiante sur des MnO2 synthétisés. En photocatalyse, les résultats mettent en évidence que la vitesse de dégradation diminue avec le taux d’humidité relative et augmente avec la puissance lumineuse et la concentration en n-pentane. Les concentrations des intermédiaires réactionnels sont de l’ordre du ppbv pour des ppmv de n-pentane injectés. L’operando DRIFTS a mis en évidence la présence de carbonates à la surface du photocatalyseur. Parallèlement, les expériences de PTR-MS-TOF-SRI et GC-MS ont permis d’identifier la présence de composés carbonylés parmi lesquels du formaldéhyde et la pentan-2-one. Ces intermédiaires ont permis de proposer un mécanisme de la dégradation du n-pentane sur TiO2 P25. Il a également été démontré que l’oxydation photocatalytique du n-pentane par TiO2 P25 permet une minéralisation pratiquement complète quelles que soient les conditions de travail. Pour le système catalytique, des oxydes de manganèse ont été synthétisés par co-précipitation puis calcinés sous oxygène à trois différentes températures : 100°C, 200°C et 300°C. Les performances catalytiques pour l’oxydation du CO ont été évaluées à température ambiante en l’absence d’humidité relative. Des méthodes en température programmée (TPD, TPO, TPR) ont permis de caractériser l’impact de la température de calcination sur la surface du dioxyde de manganèse. Les caractérisations DRX et BET ont mis en évidence la formation de la phase γ-MnO2 stable de 100°C à 300°C et de grande surface spécifique (178-197 m²/g). Les résultats montrent que les catalyseurs permettent une oxydation du monoxyde de carbone à température ambiante. Le catalyseur calciné à 100°C (MnO2-100) présente les meilleures performances avec un taux de conversion initiale de 60% à température ambiante pour 500 ppmv de CO à 10 L/h, 20%O2, (VVH = 25 000 h-1). Les catalyseurs, notamment MnO2-100, se désactivent au cours du temps à température ambiante. Cette désactivation pourrait être due à la capacité du catalyseur à renouveler ses oxygènes du réseau, impliquer dans le processus catalytique / The presence of Volatile Organic Compounds (VOCs) and carbon monoxide in indoor air is a major health issue. The vehicle cabin air is also affected by this problem, being the first mode of transportation. Most of the current depollution systems are based on trapping using adsorption methods, while photocatalytic processes offer the potential to fully degrade VOCs at room temperature in presence of relative humidity. However, carbon monoxide cannot be degraded by photocatalysis without a co-catalyst. Consequently, the room temperature oxidation catalysis of carbon monoxide has been studied. This thesis aims to develop an economical solution for cleaning the vehicle cabin air. This solution is based on crossing the photocatalytic oxidation of a target molecule the n-pentane over by TiO2 P25 and the room temperature oxidation of CO over synthesized MnO2. Results show that the n-pentane degradation rate decreases with the humidity level, and linearly increases with the irradiance power and the VOC concentration. Intermediates species are lowed concentrates (ppbv order) for ppmv of n-pentane used. Operando DRIFTS experiments highlighted the presence of formates surface species during the photocatalytic degradation of n-pentane. PTR-MS-TOF-SRI and GC-MS experiments highlighted the presence of carbonyl compounds as formaldehyde and pentan-2-one in gas phase during the degradation. Those intermediates species allowed us to propose a mechanism for the photocatalytic oxidation of n-pentane over TiO2 P25. Moreover, the efficiency of the photocatalytic degradation of n-pentane over TiO2 has been proved given that an almost complete mineralization is obtained whatever the working conditions. In catalysis, manganese oxides were synthesized by a co-precipitation method then calcined under oxygen at three different temperature: 100°C, 200°C and 300°C. The catalyst performances were evaluated for CO oxidation at room temperature in dry conditions. Temperature programmed methods were used for probing the impact of the calcination temperature on the catalyst surface. DRX and BET characterizations confirmed the formation of the phase γ-MnO2 stable between 100°C and 300°C, and a large surface area (178-197 m²/g). Results highlighted that the synthesized catalysts can oxide the CO at room temperature. The catalyst calcined at 100°C (MnO2-100) show the best performances with an initial conversion rate of 60% for 500 ppmv CO, at 10 L/h at 20% O2 (VVH = 25 000 h-1). However, a deactivation over the time of all the catalysts was observed, especially for MnO2-100. This deactivation could be related to the capacity of the catalyst to renew the oxygen bulk implied in the catalytic process
2

Refroidissement d'une armoire de Télécommunication avec Bouche Diphasique Thermosyphon / Two-phase cooling of a telecomunication cabinet

Mecheri, Boubakeur 17 February 2011 (has links)
France Télécom possède des armoires de télécommunication dont la puissance est limitée à cause de la dissipation thermique des équipements actifs qui entraîne une augmentation de leur température interne. La puissance des équipements limite le nombre de clients qu'il est possible de connecter aux services des réseaux à hauts débits. En plus de cette contrainte, les armoires sont soumises à des effets liés au climat (ensoleillement) qui peuvent être sévères et difficiles à maîtriser. Ceci nécessite l’intégration de systèmes de refroidissement permettant de maintenir la température des composants en dessous de la limite imposée (55°C). C’est dans cet objectif que ce travail de thèse a été mené au sein du laboratoire FEMTO-ST en collaboration avec le service R&D de France Télécom à Lannion. Le refroidissement par changement de phase est favorisé pour maintenir la température de fonctionnement du système stable et pour être utilisé dans les systèmes à haute densité de puissance. Les boucles diphasiques sont des systèmes de refroidissement pour le contrôle thermique et fonctionnent passivement sans pompage mécanique du fluide caloporteur. Après une étude bibliographique sur les boucles de refroidissement diphasiques et leurs applications, on a constaté que les boucles thermosiphons sont particulièrement adaptées aux applications où le faible coût, l'efficacité énergétique et la fiabilité d’entretien sont souhaités. Cette étude a été conduite en suivant un cahier de charge proposé par France Télécom qui consiste à : (i) développer un modèle numérique permettant de modéliser les transferts échangés entre l’armoire de télécommunication et le milieu ambiant, (ii) mener une étude expérimentale en vue de concevoir une boucle thermosiphon pour le refroidissement d’armoires de télécommunication.Le mémoire de cette thèse montre la limitation des systèmes de refroidissement classiques utilisant des écoulements d’air en convection forcée ou autre fluides sans changement de phase. Un modèle numérique est développé afin de permettre la prédiction des températures à l’entrée des boitiers chauffants pour différentes conditions climatiques. Le choix est porté sur l’utilisation d’une modélisation par réseau nodal. La modélisation est effectuée en tridimensionnel et en régime transitoire. Nous avons également modélisé le rayonnement solaire auquel est soumise l’armoire de télécommunication. Le modèle développé a été validé en effectuant une comparaison entre les résultats issus de la modélisation et ceux obtenus à partir des expériences menées au laboratoire et à la plateforme CLIMA chez France Télécom. Les essais sont effectués en régime transitoire en imposant une puissance électrique et en faisant varier la température ambiante ou la densité de flux thermique solaire. L’ensemble des résultats obtenus ont permis de constituer une base de données. Le deuxième objectif fixé dans le cadre de ce travail de thèse est la conception d’un système de refroidissement sous forme d’une boucle thermosiphon. La contrainte principale qui a guidée cette conception était le fait que la boucle doit refroidir l’armoire et assurer une température d’air à l’entrée des équipements inférieure à la limite imposée par la norme ETSI. Ceci nous a mené à concevoir un prototype de boucle thermosiphon dont la puissance thermique qu’il doit dissiper est imposée. On a montré que ce prototype permet de dissiper des puissances thermiques allant jusqu’à 470 W en utilisant une petite charge de npentane. Nous avons effectué des essais sur le refroidissement du prototype d’armoire de télécommunication en utilisant la boucle thermosiphon légèrement modifiée. On montre que les performances thermiques obtenues en utilisant un mode de refroidissement en boucle thermosiphon sont meilleures. Les boucles thermosiphons semblent intéressantes pour un refroidissement passif de matériels déployés dans un réseau de télécommunication... / France Telecom owns telecommunication cabinets whose power is limited because of the heat dissipation of active devices which leads to increased internal temperature. Power equipment limits the number of clients that can connect to networks services with high data rates. In addition to this constraint, the cabinets are subject to climate-related impacts (sunlight) that can be severe and difficult to master. This requires the integration of cooling systems to maintain the temperature of components below the limit (55 ° C). It is with this aim that this work was conducted in the laboratory Femto-ST in collaboration with the R & D department of France Telecom in Lannion.Cooling the phase change is promoted to maintain the operating temperature of the stable and system for use in systems with high power density. The loops are two-phase cooling systems for thermal control and operate passively without mechanical pumping of the coolant.After a literature review on two-phase cooling loops and their applications, it was found that the thermosyphon loops are particularly suitable for applications where low cost, energy efficiency and reliability maintenance are desired. This study was conducted by following a set of specifications proposed by France Telecom which involves: (i) develop a numerical model to model transfers exchanged between the cabinet and the telecommunications environment, (ii) conduct an experimental study to design a thermosyphon loop for cooling telecommunication cabinets.The memory of this thesis shows the limitation of conventional cooling systems using air flow forced convection or other fluids without phase change. A numerical model is developed to enable the prediction of temperatures at the inlet of heated enclosures for different climatic conditions. The choice is focused on the use of a nodal network modeling. The modeling is done by three-dimensional and transient. We also modeled the solar radiation, which applies to the telecommunications closet. The developed model was validated by comparison between the results of modeling and those obtained from experiments in the laboratory and platform CLIMA at France Telecom. The tests are performed by imposing transient electrical power and varying the temperature or heat flux density solar. All the results obtained allowed to establish a database.The second goal as part of this thesis is the design of a cooling system as a thermosyphon loop. The main constraint has guided this design was that the loop needs to cool the cabinet and provide air temperature at the inlet of the equipment below the limit imposed by the ETSI. This led us to design a prototype of thermosyphon loop with a heat output that must be dissipated is imposed. We showed that this prototype is used to dissipate the heat ratings up to 470 W using a small load of npentane.We conducted tests on the prototype cooling telecommunication cabinet using slightly modified thermosyphon loop. We show that the thermal performance obtained by using a cooling mode loop thermosyphon are better. Thermosyphon loops seem interesting for passive cooling of equipment deployed in a telecommunications network. Indeed, being able to use an air conditioning system independent and requires no energy should be promoted in a reduction of overall energy consumption.
3

Schwingungsspektroskopie nah- und überkritischer Lösungsmittel / Vibrational spectroscopy of near- and supercritical solvents

Abraham, Sascha 27 June 2013 (has links)
Expansionen komprimierter Fluide finden breite Anwendung und werden hier mit Hilfe der Schwingungsspektroskopie untersucht. Dabei ist der Aggregatzustand der bei der Zerstäubung entstehenden Partikel von besonderem Interesse. In Abhängigkeit von Stagnationsdruck, Düsentemperatur, und Düsenabstand werden neben Lachgas tert-Butylalkohol und n-Pentan hinsichtlich ihrer Partikelbildung charakterisiert. Die Ergebnisse bilden eine Grundlage für die Expansion nahkritischer Lösungen.
4

Refroidissement d'une armoire de Télécommunication avec Bouche Diphasique Thermosyphon

Mecheri, Boubakeur 17 February 2011 (has links) (PDF)
France Télécom possède des armoires de télécommunication dont la puissance est limitée à cause de la dissipation thermique des équipements actifs qui entraîne une augmentation de leur température interne. La puissance des équipements limite le nombre de clients qu'il est possible de connecter aux services des réseaux à hauts débits. En plus de cette contrainte, les armoires sont soumises à des effets liés au climat (ensoleillement) qui peuvent être sévères et difficiles à maîtriser. Ceci nécessite l'intégration de systèmes de refroidissement permettant de maintenir la température des composants en dessous de la limite imposée (55°C). C'est dans cet objectif que ce travail de thèse a été mené au sein du laboratoire FEMTO-ST en collaboration avec le service R&D de France Télécom à Lannion. Le refroidissement par changement de phase est favorisé pour maintenir la température de fonctionnement du système stable et pour être utilisé dans les systèmes à haute densité de puissance. Les boucles diphasiques sont des systèmes de refroidissement pour le contrôle thermique et fonctionnent passivement sans pompage mécanique du fluide caloporteur. Après une étude bibliographique sur les boucles de refroidissement diphasiques et leurs applications, on a constaté que les boucles thermosiphons sont particulièrement adaptées aux applications où le faible coût, l'efficacité énergétique et la fiabilité d'entretien sont souhaités. Cette étude a été conduite en suivant un cahier de charge proposé par France Télécom qui consiste à : (i) développer un modèle numérique permettant de modéliser les transferts échangés entre l'armoire de télécommunication et le milieu ambiant, (ii) mener une étude expérimentale en vue de concevoir une boucle thermosiphon pour le refroidissement d'armoires de télécommunication.Le mémoire de cette thèse montre la limitation des systèmes de refroidissement classiques utilisant des écoulements d'air en convection forcée ou autre fluides sans changement de phase. Un modèle numérique est développé afin de permettre la prédiction des températures à l'entrée des boitiers chauffants pour différentes conditions climatiques. Le choix est porté sur l'utilisation d'une modélisation par réseau nodal. La modélisation est effectuée en tridimensionnel et en régime transitoire. Nous avons également modélisé le rayonnement solaire auquel est soumise l'armoire de télécommunication. Le modèle développé a été validé en effectuant une comparaison entre les résultats issus de la modélisation et ceux obtenus à partir des expériences menées au laboratoire et à la plateforme CLIMA chez France Télécom. Les essais sont effectués en régime transitoire en imposant une puissance électrique et en faisant varier la température ambiante ou la densité de flux thermique solaire. L'ensemble des résultats obtenus ont permis de constituer une base de données. Le deuxième objectif fixé dans le cadre de ce travail de thèse est la conception d'un système de refroidissement sous forme d'une boucle thermosiphon. La contrainte principale qui a guidée cette conception était le fait que la boucle doit refroidir l'armoire et assurer une température d'air à l'entrée des équipements inférieure à la limite imposée par la norme ETSI. Ceci nous a mené à concevoir un prototype de boucle thermosiphon dont la puissance thermique qu'il doit dissiper est imposée. On a montré que ce prototype permet de dissiper des puissances thermiques allant jusqu'à 470 W en utilisant une petite charge de npentane. Nous avons effectué des essais sur le refroidissement du prototype d'armoire de télécommunication en utilisant la boucle thermosiphon légèrement modifiée. On montre que les performances thermiques obtenues en utilisant un mode de refroidissement en boucle thermosiphon sont meilleures. Les boucles thermosiphons semblent intéressantes pour un refroidissement passif de matériels déployés dans un réseau de télécommunication...
5

Condensation of hydrocarbon and zeotropic hydrocarbon/refrigerant mixtures in horizontal tubes

Milkie, Jeffrey A. 22 May 2014 (has links)
An experimental investigation of condensation of hydrocarbons and hydrocarbon/refrigerant mixtures in horizontal tubes was conducted. Heat transfer coefficients and frictional pressure drops during condensation of a zeotropic binary mixture of R245fa and n-pentane in a 7.75 mm internal diameter round tube were measured across the entire vapor-liquid dome, for mass fluxes ranging from 150 to 600 kg m-2 s-1, and reduced pressures ranging from 0.06 to 0.23. Condensation experiments were conducted for the mixture, as well as its pure constituents over a similar range of conditions. In addition, condensing flow of the hydrocarbon propane was documented visually using high-speed video recordings. Results from these experiments were used to establish the two-phase flow regimes, void fractions, and liquid film thicknesses during condensation of propane flowing through horizontal tubes with internal diameters of 7 and 15 mm. These measurements were made over mass fluxes ranging from 75 to 450 kg m-2 s-1, operating pressures ranging from 952 to 1218 kPa, and vapor qualities ranging from 0.05 to 0.95. Liquid film thickness and void fraction data were subsequently be used to assist the development of heat transfer and pressure drop models. In particular, the heat transfer coefficients and pressure drops observed in the mixture were compared with the corresponding values for the pure constituents. Models for heat transfer and pressure drop in the pure components as well as the mixtures were developed based on the data from the present study. This work extends the available literature on two-phase flow regimes for air-water mixtures, steam, and refrigerants to include hydrocarbons. Additionally, the limited information on condensation in multi-constituent hydrocarbon-hydrocarbon and refrigerant-refrigerant mixtures was extended to include hydrocarbon-refrigerant mixtures. The findings of this study are expected to benefit applications such as refrigeration, low-grade heat-driven power generation, and the development of heat exchangers for the chemical and process industries.

Page generated in 0.063 seconds