11 |
Efeito da associação de fosfato de cálcio, laser Nd:YAG e adesivo na permeabilidade dentinária e na resistência de união / Effect of the association of calcium phosphate, Nd:YAG laser and adhesive on dentin permeability and bond strengthBenitez Sellan, Pablo Lenin 11 December 2017 (has links)
Submitted by PABLO LENIN BENITEZ SELLAN null (drpablobens@gmail.com) on 2017-12-14T18:23:53Z
No. of bitstreams: 1
Dissertação Pablo Benitez Mestrado Dentistica.pdf: 11665620 bytes, checksum: 383da8829341bad52fdb34ed88ead959 (MD5) / Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2017-12-18T15:13:01Z (GMT) No. of bitstreams: 1
benitezsellan_pl_me_sjc.pdf: 11665620 bytes, checksum: 383da8829341bad52fdb34ed88ead959 (MD5) / Made available in DSpace on 2017-12-18T15:13:01Z (GMT). No. of bitstreams: 1
benitezsellan_pl_me_sjc.pdf: 11665620 bytes, checksum: 383da8829341bad52fdb34ed88ead959 (MD5)
Previous issue date: 2017-12-11 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar in vitro o efeito do tratamento com a associação de fosfato de cálcio, laser de Nd:YAG e sistema adesivo na permeabilidade dentinária e na resistência de união. Foram utilizados 60 discos de dentina com aproximadamente 6 mm de diâmetro e 1,5 mm de altura, obtidos de molares humanos hígidos. Os espécimes foram divididos em dois grupos de acordo com a prévia aplicação ou não do fosfato de cálcio (TeethMate Desensitizer - Kuraray Notitake Dental Inc.). Cada grupo foi dividido em três subgrupos conforme o tratamento realizado (n=10): A- Adesivo (Single Bond Universal - 3M-ESPE), AL- Adesivo + Laser (Nd: YAG 60 mJ) , LAL- Laser + Adesivo + Laser. A permeabilidade foi mensurada em três momentos: com smear layer presente (inicial), após a abertura dos túbulos (máxima) e depois do tratamento (final). O percentual da permeabilidade inicial e final foi calculada em relação a permeabilidade máxima. Após a fotopolimerização do adesivo foi aplicado uma camada de 3 mm com a resina composta Filtek Z350 XT (3M-ESPE) com técnica incremental. Os espécimes foram submetidos a 5000 ciclos térmicos e 120.000 ciclos mecânicos, e posteriormente foi utilizado o teste de microtração. Adicionalmente foram observados em microscopia eletrônica de varredura (MEV) e microscopia confocal de varredura a laser (MCVL). Os grupos foram analisados pelo teste da analise de variância (ANOVA), teste t pareado e teste Tukey, adotando o nível de significância de 5%. Não foram observadas diferenças significativas entre os grupos na permeabilidade inicial (p=0,48) e após o tratamento (p=0,70). O percentual de permeabilidade após o tratamento foram (A: 42,11; AL: 39,09; LAL: 35,78; FA: 40,38; FAL: 34,23; FLAL: 30,25). O teste t pareado mostrou que o tratamento LAL promoveu uma redução significativa da permeabilidade em relação à inicial, tendo o fosfato de cálcio sido (p=30,25) ou não aplicado (p=35,78). Os tratamentos tiveram diferenças significativas na resistência de união, foi observado que os grupos FAL(31,53MPa), FLAL(31,37MPa) e AL(29,72MPa) apresentaram as maiores médias, que diferiram estatisticamente dos grupos restaurados só com Adesivo. Os demais grupos não apresentaram diferenças significantes (A: 24,34MPa; FA: 26,40MPa; LAL: 29,68MPa). Podemos concluir que o laser Nd:YAG aplicado antes e depois do sistema adesivo (Com e sem Fosfato de Cálcio), influenciou na redução da permeabilidade dentinária e os diferentes tratamentos na dentina influenciam significativamente a resistência de união entre a dentina e a resina, os grupos FAL, FLAL e AL apresentaram os melhores resultados. A correlação entre os parâmetros não teve influencia. / The objective of this study was to evaluate in vitro effect the association of calcium phosphate, Nd:YAG laser and adhesive system on dentin permeability and bond strength. Sixty dentin discs, approximately 6 mm in diameter and 1,5 mm high, were obtained from healthy human molars. The specimens were divided into two groups according to the prior application of calcium phosphate (TeethMate Desensitizer - Kuraray Noritake Dental Inc.). Each group was divided into three subgroups according to the treatment performed: A-Adhesive (Single Bond Universal - 3M-ESPE), AL- Adhesive + Laser (Nd: YAG 60 mJ) and LAL- Laser + Adhesive + Laser. The dentin permeability was measured in three moments: with smear layer present (initial), after opened tubules (maximum) and after treatment (final). The percentage of the initial and final permeability was calculated in relation to the maximum permeability. After adhesive photopolymerization, was applied the composite resin Filtek Z350 XT (3M-ESPE) with incremental technique. The specimens were cycled to 5000 thermal cycles and 120,000 mechanical cycles, and microtensile bond strength test was applied. Additionally they were observed in scanning electron microscopy (SEM) and confocal laser scanning microscopy (CLSM). The groups were analyzed by ANOVA, paired t test and Tukey test (5%). No significant differences were observed between the groups on initial permeability (p=0.48) and after treatment (p=0.70). Permeability percentage after treatment was (A: 42.11, AL: 39.09, LAL: 35.78, FA: 40.38, FAL: 34.23, FLAL: 30.25). The paired t-test showed that LAL treatment promoted a significant reduction of the permeability in relation to the initial one, with calcium phosphate (p=30.25) or not applied (p=35.78). The treatments had significant differences in bond strength; FAL (31,53 MPa), FLAL (31,37 MPa) and AL (29,72 MPa) groups presented the highest averages, which differed statistically from the groups restored with only Adhesive. The other groups did not present statistically significant differences (A: 24.34 MPa, AF: 26.40 MPa, LAL: 29.68 MPa). It can be concluded that when the Nd:YAG laser was applied before and after the adhesive system (with and without Calcium Phosphate), it influenced the reduction of dentin permeability and the different treatments in dentin significantly influenced the bond strength between dentin and resin , the groups AL, LAL with application of Phosphate and AL without the use of Phosphate showed the best results. The correlation between the parameters had no influence.
|
12 |
Avaliação da variação da temperatura em amostras de esmalte/dentina e dentina, após irradiação com os lasers de Nd:YAG, Er:YAG (Kavo KEY Laser®) e Er:YAG (Kavo KEY Laser® 3): análise com termômetro de radiação infravermelha / Evaluation of the variance in temperature of the enamel/dentin and dentin samples after irradiation with Nd:YAG, Er:YAG (Kavo KEY Laser®) and Er:YAG (Kavo KEY Laser® 3) Infrared radiation thermometer analysisMarcia Tonetti Ciaramicoli 16 September 2004 (has links)
Desde o desenvolvimento do laser pelo norte-americano Theodore Harold Maiman em 1960, inúmeras pesquisas têm sido realizadas com o objetivo de avaliar os efeitos sobre os tecidos dentais, principalmente os relacionados com o aumento de temperatura no interior da câmara pulpar. Esta pesquisa foi desenvolvida com o objetivo de avaliar a variação de temperatura em amostras de esmalte/dentina e dentina, após irradiação com os lasers de Nd:YAG, Er:YAG (Kavo KEY Laser®) e Er:YAG (Kavo KEY Laser® 3), através de análise com termômetro de radiação infravermelha. Foram selecionados 110 terceiros molares isentos de cárie, obtidos através do Banco de Dentes Permanentes Humanos que pertence à Faculdade de Odontologia da Universidade de São Paulo e o projeto de pesquisa foi aprovado pelo Comitê de Ética em Pesquisa (CEP) com o parecer nº44/03. As coroas foram separadas das raízes por meio de um disco de carborundum e todas as coroas foram totalmente incluídas no interior de um tubo de PVC com resina transparente. Os cortes foram realizados no aparelho de corte Labcut, paralelamente ao longo eixo das coroas, no sentido mésio-distal, para obter 750 amostras, com 5 diferentes espessuras (1mm, 2mm, 3mm, 4mm e 5mm), sendo 350 amostras de esmalte/dentina e 400 amostras de dentina. Foi utilizado um termômetro de radiação infravermelha (MINIRAY 100 XL) para medição da variação de temperatura nos dois lados das amostras (frente e atrás), irradiadas em diferentes condições e parâmetros com os lasers de Nd:YAG, Er:YAG (Kavo KEY Laser®) e Er:YAG (Kavo KEY Laser® 3). Os resultados obtidos com todos os lasers e parâmetros demonstraram que a associação refrigeração + espessura das amostras foi estatisticamente significante, quanto à redução da variação de temperatura em comparação à associação ausência de refrigeração + espessura das amostras. Houve uma diminuição da variação da temperatura estatisticamente significante de acordo com as espessuras das amostras irradiadas sem refrigeração, porém não o suficiente para evitar grandes elevações de temperatura. No geral, as variações das temperaturas foram sempre maiores no lado da frente das amostras, independente do uso ou não de refrigeração. Para o laser de Nd:YAG, houve menores variações de temperatura, estatisticamente significante, nos grupos irradiados sem contato e sem a presença da tinta nanquim, independente da presença ou não de refrigeração. / The laser was developed in 1960 by Theodore Harold Maiman and many researches have been carried out with the aim to evaluate the effects on the dental tissues, mainly the effects related to the increase of temperature inside the pulp chamber. This research was developed with the purpose of evaluating the variance in temperature of the enamel/dentin and dentin samples after irradiation with Nd:YAG, Er:YAG (Kavo KEY Laser®) and Er:YAG (Kavo KEY Laser® 3) and an analysis with the infrared radiation thermometer was done. A hundred and ten teeth without dental caries were selected and obtained from the Human Permanent Teeth Bank that belongs to the Odontology College of the University of São Paulo and this research has been approved by the Ethic Research Committee (CEP), as the document n° 44/03 attests. The roots were separated from the crowns with the carburundum disc; all crowns were totally inserted inside a PVC tube with transparent resin and they were cut axially in the Labcut machine, in the mesio-distal way, to obtain 750 samples with five different thickness (1mm, 2mm, 3mm, 4mm e 5mm), 350 enamel/dentin samples and 400 dentin samples. An infrared radiation thermometer (MINIRAY 100XL) was used to measure the variance in temperature in both sides of the samples (front and behind), irradiated in different conditions and parameters with the Nd:YAG, Er:YAG (Kavo KEY Laser®) and Er:YAG (Kavo KEY Laser® 3). The results showed that the association of the refrigeration + samples thickness was statistically significant in the reduction of the variance in temperature when compared to the association of the refrigeration absence + samples thickness. There was a statistically significant reduction of the variance in temperature according to the the samples thickness irradiated without refrigeration, although it wasnt enough to avoid high temperature increase. In general, the variance in temperature was always higher in the front of samples, whether there was refrigeration or not. For the Nd:YAG laser, there was a lower variance in temperature, statistically significant, in the groups that were irradiated without contact and black ink, whether there was refrigeration or not.
|
13 |
Retrospektiver Vergleich der Behandlungsergebnisse konventioneller Resektionstechniken des NSCLC im Stadium Ia/Ib mit Lasersegmentresektionen unter Anwendung eines neu entwickelten 1318nm Nd:YAG-LasersHuscher, Stefan 06 November 2007 (has links)
Unter den bösartigen Tumoren hat das Bronchialkarzinom wohl die dramatischste Entwicklung genommen. Die Inzidenz und Mortalität ist in den letzten 15-20 Jahren bei Männern zwar leicht rückläufig, für Frauen ist jedoch ein entgegen gesetzter Trend zu erkennen. Dies wird in erster Linie auf die veränderten Lebensgewohnheiten, wie steigender Zigarettengenuss unter den Frauen, zurückgeführt. Derzeit gibt es in Deutschland circa 20 Millionen Raucher, von denen etwa 140˙000 jährlich an den Folgen ihres Inhalationsrauchens versterben...
|
14 |
Evaluation of particle release during cleaning of coated surfaces with pulsed Nd:YAG laserKahl, Torsten, Lohse, Franz, Herrmann, Marion, Hurtado, Antonio 07 June 2024 (has links)
The released particles during laser-based surface ablation of an epoxy resin coating were investigated for their number, size, mass and chemical composition. The laser used was a pulsed Nd:YAG laser with a maximum average power of 91 W. During the experiments, the applied laser power was investigated as a varying parameter. With the highest power, a maximum particle count of 4.3*108 particles/cm³ was measured, which corresponds to a mass of approximately 55 mg/m³. With decreasing laser power, the particle loading of the aerosol decreases. The particle sizes are bimodal distributed between 10 nm and approximately 3 μm. The first peak is at 34 nm and the second peak is at 630 nm. In terms of number, the nanoparticles dominate the distribution. During the analysis of the particles, fractal and spherical particles were determined, whereby the fractal particles are mainly in the nanometre range and the spherical particles mostly in the μm range. The chemical analysis of the particles showed that they consist of carbon and hydrogen.
|
15 |
Avaliação in vitro da resistência adesiva e degradação da interface de união entre cimentos resinosos e uma cerâmica aluminizada tratada internamente com laser / In Vitro analsis of bond strength and degradation method between bond interface of aluminous ceramic and resin cementsSilveira, Bruno Lopes da 04 July 2008 (has links)
O estudo teve o objetivo de avaliar a resistência adesiva e a degradação da interface entre uma cerâmica tratada com laser e cimentos resinosos. Sessenta e quatro blocos cerâmicos foram distribuídos em 16 grupos distribuídos de acordo com os fatores em estudo: tratamento da superfície interna da cerâmica: Oxido de Alumínio (Ox), Rocatec (R), Laser de Nd:YAG 141,54 J/cm2 (Nd) e Laser de Nd:YAG + Rocatec (NdR); cimentos resinosos: Panavia F (Kuraray) e Relyx Unicem (3M ESPE); e método de envelhecimento: água destilada (W) e hipoclorito de sódio 10% (H). Após os procedimentos de cimentação e corte dos blocos, metade dos palitos foi armazenada em solução de hipoclorito de sódio 10% para simular envelhecimento in vitro. A resistência de união foi avaliada através do ensaio de microtração (0,5 mm/min) e os padrões de fratura foram classificados em adesivo, coesivo ou misto. Blocos cerâmicos adionciais foram confeccionados e analisados em Microscopia Eletrônica de Varredura e em Microscópio de Força Atômica para verificação dos padrões gerados pelos tratamentos. Os grupos tratados com laser de Nd:YAG apresentaram os maiores valores de resistência de união. Para os grupos cimentados com Panavia F, os valores de resistência de união foram: OxW: 27,71±6,3; RW: 35,67±5,13; NdW: 42,49±6,8; NdRW: 37,41±4,76; OxH: 22,27±6,05; RH: 27,49±8,83; NdH: 32,24±6,94; NdRH: 31,75±7,77. Para os grupos com RelyX Unicem: OxW: 26,74±6,34; RW: 35,07±6,02; NdW: 41,05±7,71; NdRW: 33,85±6,03; OxH: 22,77±7,37; RH: 27,84±6,26; NdH: 36,42±5,08; NdRH: 27,6±5,8. Pode-se concluir que o laser de Nd:YAG foi o tratamento mais efetivo, seguido da associação entre o laser de Nd:YAG+Rocatec, Rocatec e jateamento com Al2O3. Os cimentos testados apresentam comportamentos similares. O envelhecimento in vitro com hipoclorito de sódio diminuiu os valores de resistência de união. / The aim of this study was to evaluate the influence of different surface treatments on resistance to degradation between In-Ceram Alumina and two resin-based cements. Sixteen experimental groups were formed according to ceramic treatment: Sandblasting (S), Rocatec System (R), Nd:YAG Laser (Nd), Nd:YAG Laser plus Rocatec System (NR); luting cement: Panavia F (Kuraray) or Relyx Unicem (3M ESPE); and aging method: water (W) or sodium hypochlorite (H). Sixty four In-Ceram Alumina blocks (10x10x6mm) received four surface treatments: Al2O3 sandblasting; Al2O3 sandblasting + Rocatec Plus; Al2O3 sandblasting + Nd:YAG Lase; Al2O3 sandblasting + Nd:YAG Laser + Rocatec Plus. Each conditioned ceramic block was bonded to a composite block using a resin cement system. After 24h storage time, the blocks were sectioned to obtain sticks with cross-sectional area of 1.0mm2. The specimens were loaded to failure in a universal testing machine at a crosshead speed of 0.5mm/min. The fractured surface morphology of the debonded specimens was observed (40X) to evaluate the fracture pattern. Failure modes were classified as adhesive, cohesive in ceramic, cohesive in resin cement and mixed. The ceramic treatment and the aging method significantly affected the microtensile bond strength. Nd:YAG surface treatment resulted in the best bond strength values. To groups luted with Panavia F cement the microtensile bond strength values were: SW: 27,71±6,3; RW: 35,67±5,13; NdW: 42,49±6,8; NdRW: 37,41±4,76; SH: 22,27±6,05; RH: 27,49±8,83; NdH: 32,24±6,94; NdRH: 31,75±7,77. To groups luted with RelyX cement: SW: 26,74±6,34; RW: 35,07±6,02; NdW: 41,05±7,71; NdRW: 33,85±6,03; SH: 22,77±7,37; RH: 27,84±6,26; NdH: 36,42±5,08; NdRH: 27,6±5,8. Nd:YAG laser was the most effective surface treatment, followed by Nd:YAG+Rocatec, Rocatec and Al2O3 sandblasting. Resin cements presented similar behaviors in spite of aging. NaOCl 12h-immersion decreased Bond strength values.
|
16 |
Eficácia do laser de Nd:YAG associado à raspagem no tratamento de lesões de furca grau II: estudo clínico e microbiológico / Efficacy of Nd:YAG laser associated with scaling and root planning in class II furcation - clinical and microbiological studyAndrade, Ana Karina Pinto de 03 June 2009 (has links)
O objetivo deste ensaio-clínico, aleatório, duplo-cego foi avaliar as alterações clínicas e no número de bactérias obtidas com o uso do laser de Nd:YAG associado à raspagem em furcas grau II de pacientes com periodontite crônica. Num modelo de boca dividida, sessenta e duas furcas (62) grau II foram selecionadas de trinta e um (31) pacientes que receberam tratamento periodontal prévio da boca toda com exceção dos sítios experimentais. As trinta e uma (31) furcas do grupo Controle receberam duas sessões, com intervalo semanal, de raspagem, alisamento e polimento corono-radicular manual associado ao ultrassom. O grupo Teste recebeu o mesmo tratamento que o Controle, seguido da aplicação do laser de Nd:YAG (100mJ/pulso; 15Hz; 1,5W; 60seg, 141,50J/cm2). Os parâmetros clínicos avaliados antes, um, três, e seis meses depois do tratamento foram: Índice Gengival (IG), Índice de Placa (IP), Distância Junção Esmalte Cemento - Margem Gengival (JEC-MG), Profundidade Clínica de Sondagem do Componente Horizontal (FH) e Vertical (FV) da Furca e Nível Clínico de Inserção (NCI). Os parâmetros microbiológicos coletados antes, imediatamente após, um, três, e seis meses depois do tratamento foram: número de Unidades Formadoras de Colônias (UFCs) de bactérias totais; número total de UFCs de bactérias pigmentadas de preto; porcentagem de pacientes com Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis e Prevotella intermedia Os resultados demonstraram uma redução significativa das UFCs de bactérias totais em ambos os grupos, sendo esta maior no grupo Teste imediatamente após o tratamento. Após um e três meses, houve um aumento desse número, porém não alcançando os níveis iniciais para ambos os grupos. Já aos seis meses houve um novo aumento do número de UFCs de bactérias totais alcançando níveis próximos dos inicias no grupo Teste, enquanto o grupo Controle manteve-se semelhante aos três meses. As UFCs de bactérias pigmentadas de preto e a porcentagem de pacientes com as bactérias estudadas, se comportaram da mesma forma para ambos os grupos, tendo uma redução imediatamente após o tratamento, e um retorno à níveis próximos dos iniciais após seis meses. Para os valores de, IP, IG, FV, FH e NCI foi observado uma redução ao longo do experimento, porém sem diferença entre os grupos, e para distância JEC-MG houve um aumento ao longo do estudo também sem diferença entre os grupos. Conclui-se que o laser de Nd:YAG associado à raspagem promoveu redução bacteriana nas furcas grau II imediatamente após o tratamento, porém essa redução adicional não foi observada durante os demais tempos experimentais e que ambos os tratamento promoveram melhoras na maioria dos parâmetros clínicos avaliados ao longo do estudo. / The purpose of this clinical trial, randomized, double-blinded was to evaluated the bacterial reduction and the clinical improvement achieved with the Nd:YAG associated to conventional treatment on furcation sites of patients with chronic periodontitis. In a split mouth design study, sixty two (62) class II furcations were selected from thirty one (31) patients that received previous full mouth periodontal treatment, except for the experimental sites. The thirty one (31) furcations of the Control group underwent twice manual and ultrasonic root debridment in weekly intervals. The Test group received the same treatment as the Control group followed by the Nd:YAG laser irradiation (100mJ/pulse; 1.5W; 15Hz; 60sec, 141.50J/cm2). The clinical parameters evaluated before, one, three, and six months after the treatment were: Gingival Index (GI), Plaque Index (PI), Clinical Pocket Depth of Furcation Horizontal (HF) and Vertical (VF) Components, Cement Enamel Junction Gingival Margin distance (CEJ-GM) and Clinical Attachment Level (CAL). The microbiological parameters evaluated before, immediately, one, three and six months after the treatment were: Colony Forming Units (CFU) of total bacteria number; CFU of dark pigmented bacteria and the percentage values of patients with Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis and Prevotella intermedia. The results showed a CFU total bacteria number significant reduction for both groups immediately after the treatment, but it was significant higher for the Test group. After one and three months, an increase of this number was observed, however not reaching the initial levels for both groups. At the six months an increase almost equal to baseline levels in Test group was showed, while the Control group still similar to the three months results. The CFU of dark pigmented bacteria and the percentage values of patients with the studied bacteria, reduced after the treatment and returned to values close to the initial ones six months after the baseline for both groups. The VF, HF, CAL, PI and GI values reduced throughout the study, however with no difference between then, and for CEJGM distance an increase was noted throughout the study without significant difference between the groups. It was concluded that the Nd: YAG laser associated with scaling and root planning promoted bacterial reduction on class II furcation immediately after its application, although this reduction was not observed six months after and that both treatments promoted improvements of most clinical parameters throughout the study.
|
17 |
Avaliação in situ da associação do verniz fluoretado ao laser de Er:YAG e ao laser de Nd:YAG na permeabilidade da dentina radicular erodida / In Situ Evaluation of Associating the Fluoride Varnish to Er:YAG or Nd:YAG Laser at permeability of eroded root dentin.Nemezio, Mariana Alencar 04 June 2013 (has links)
O objetivo do presente estudo foi avaliar in situ o efeito da associação do verniz fluoretado ao laser de Er:YAG e ao laser Nd:YAG na permeabilidade da dentina radicular erodida. Quarenta e oito fragmentos de dentina radicular bovina, com dimensões 2x2x2 mm, foram submetidos a um desafio erosivo inicial com ácido cítrico (0,3%, pH 3,2), por duas horas, sob agitação e armazenados em saliva artificial por vinte e quatro horas. Posteriormente, os espécimes foram divididos em relação aos tratamentos: verniz fluoretado e não fluoretado e subdivididos conforme a irradiação: laser de Er:YAG (100mJ, 3Hz), laser de Nd:YAG (70mJ, 15 Hz) e não irradiado. Após um período de lead in (2 dias), os voluntários (n=8) utilizaram dispositivos palatinos contendo três espécimes que foram submetidos a desafios erosivos ex vivo, quatro vezes ao dia, com ácido cítrico (0,3%, pH 3,2), durante 90s, por cinco dias. Na primeira fase do experimento, metade dos voluntários utilizou dispositivos contendo fragmentos tratados com verniz fluoretado, verniz fluoretado + laser de Er:YAG e verniz fluoretado + laser de Nd:YAG. A outra metade utilizou verniz não fluoretado, verniz não fluoretado + laser de Er:YAG e verniz não fluoretado + laser de Nd:YAG. Depois de um período de wash-out (15 dias), os voluntários foram cruzados quanto aos tratamentos, caracterizando um experimento cross-over 2x2. Ao final de cada fase experimental, a permeabilidade dentinária foi avaliada. A ANOVA dois critérios e o teste complementar de Duncan revelaram uma diferença significativa entre os espécimes tratados com o verniz fluoretado (p=0,005), verniz fluoretado + laser de Er:YAG (p=0,014) e verniz fluoretado + laser de Nd:YAG (p=0,025), em comparação aos tratados com verniz não fluoretado. Observou-se que, independentemente da associação aos lasers (Er:YAG ou Nd:YAG), o verniz fluoretado foi capaz de promover a redução da permeabilidade da dentina radicular erodida. Não se observou efeito adicional com a associação dos tratamentos. / The present study aimed to evaluate in situ the effect of associating the fluoride varnish to Er:YAG or Nd:YAG laser at permeability of eroded root dentin. Forty-eight specimens of bovine root dentin (2x2x2mm) were subjected to initial erosive challenge with citric acid (0.3%, pH 3.2), for 2 hours under agitation and stored at artificial saliva, at 37° C, for 24 hours, followed by a remineralization period in artificial saliva. After that, specimens were divided according to the treatment: fluoride varnish and non-flouride varnish, and subdivided according to the irradiation: Er:YAG laser (100mJ, 3Hz), Nd:YAG laser (70mJ, 15Hz) and non-irradiated. After a lead-in period (2 days), 8 volunteers (n=8) wore a palatal device containing 3 specimens that was subjected to erosive challenges ex vivo, four times a day with citric acid (0.3%, pH3.2), for 90s, during 5 days. At the first experimental phase, half of volunteers wore devices containing specimens treated with fluoride varnish, fluoride varnish + Er:YAG laser and fluoride varnish + Nd:YAG laser, and the other half wore the specimens treated with non-fluoride varnish, non-fluoride varnish + Er:YAG laser and non-flouride varnish + Nd:YAG laser. After a wash-out period (15 days), volunteers were crossed to different treatment, characterizing a 2x2 cross-over experiment. At the end of each experimental phase, the dentinal permeability was evaluated. Two-way ANOVA and Duncans test revealed a significant difference between specimens treated with fluoride varnish (p=0,005), fluoride varnish + Er:YAG laser (p=0,014) and fluoride varnish + Nd:YAG (p=0,025) compared to specimens treated with no-fluoride varnish. It was observed that regardless of association to laser (Er:YAG or Nd:YAG), fluoride varnish was able to promote, in situ, the reduction of permeability of eroded root dentin, but no additional effect was observed when the treatments were associated.
|
18 |
Eficácia do laser de Nd:YAG associado à raspagem no tratamento de lesões de furca grau II: estudo clínico e microbiológico / Efficacy of Nd:YAG laser associated with scaling and root planning in class II furcation - clinical and microbiological studyAna Karina Pinto de Andrade 03 June 2009 (has links)
O objetivo deste ensaio-clínico, aleatório, duplo-cego foi avaliar as alterações clínicas e no número de bactérias obtidas com o uso do laser de Nd:YAG associado à raspagem em furcas grau II de pacientes com periodontite crônica. Num modelo de boca dividida, sessenta e duas furcas (62) grau II foram selecionadas de trinta e um (31) pacientes que receberam tratamento periodontal prévio da boca toda com exceção dos sítios experimentais. As trinta e uma (31) furcas do grupo Controle receberam duas sessões, com intervalo semanal, de raspagem, alisamento e polimento corono-radicular manual associado ao ultrassom. O grupo Teste recebeu o mesmo tratamento que o Controle, seguido da aplicação do laser de Nd:YAG (100mJ/pulso; 15Hz; 1,5W; 60seg, 141,50J/cm2). Os parâmetros clínicos avaliados antes, um, três, e seis meses depois do tratamento foram: Índice Gengival (IG), Índice de Placa (IP), Distância Junção Esmalte Cemento - Margem Gengival (JEC-MG), Profundidade Clínica de Sondagem do Componente Horizontal (FH) e Vertical (FV) da Furca e Nível Clínico de Inserção (NCI). Os parâmetros microbiológicos coletados antes, imediatamente após, um, três, e seis meses depois do tratamento foram: número de Unidades Formadoras de Colônias (UFCs) de bactérias totais; número total de UFCs de bactérias pigmentadas de preto; porcentagem de pacientes com Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis e Prevotella intermedia Os resultados demonstraram uma redução significativa das UFCs de bactérias totais em ambos os grupos, sendo esta maior no grupo Teste imediatamente após o tratamento. Após um e três meses, houve um aumento desse número, porém não alcançando os níveis iniciais para ambos os grupos. Já aos seis meses houve um novo aumento do número de UFCs de bactérias totais alcançando níveis próximos dos inicias no grupo Teste, enquanto o grupo Controle manteve-se semelhante aos três meses. As UFCs de bactérias pigmentadas de preto e a porcentagem de pacientes com as bactérias estudadas, se comportaram da mesma forma para ambos os grupos, tendo uma redução imediatamente após o tratamento, e um retorno à níveis próximos dos iniciais após seis meses. Para os valores de, IP, IG, FV, FH e NCI foi observado uma redução ao longo do experimento, porém sem diferença entre os grupos, e para distância JEC-MG houve um aumento ao longo do estudo também sem diferença entre os grupos. Conclui-se que o laser de Nd:YAG associado à raspagem promoveu redução bacteriana nas furcas grau II imediatamente após o tratamento, porém essa redução adicional não foi observada durante os demais tempos experimentais e que ambos os tratamento promoveram melhoras na maioria dos parâmetros clínicos avaliados ao longo do estudo. / The purpose of this clinical trial, randomized, double-blinded was to evaluated the bacterial reduction and the clinical improvement achieved with the Nd:YAG associated to conventional treatment on furcation sites of patients with chronic periodontitis. In a split mouth design study, sixty two (62) class II furcations were selected from thirty one (31) patients that received previous full mouth periodontal treatment, except for the experimental sites. The thirty one (31) furcations of the Control group underwent twice manual and ultrasonic root debridment in weekly intervals. The Test group received the same treatment as the Control group followed by the Nd:YAG laser irradiation (100mJ/pulse; 1.5W; 15Hz; 60sec, 141.50J/cm2). The clinical parameters evaluated before, one, three, and six months after the treatment were: Gingival Index (GI), Plaque Index (PI), Clinical Pocket Depth of Furcation Horizontal (HF) and Vertical (VF) Components, Cement Enamel Junction Gingival Margin distance (CEJ-GM) and Clinical Attachment Level (CAL). The microbiological parameters evaluated before, immediately, one, three and six months after the treatment were: Colony Forming Units (CFU) of total bacteria number; CFU of dark pigmented bacteria and the percentage values of patients with Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis and Prevotella intermedia. The results showed a CFU total bacteria number significant reduction for both groups immediately after the treatment, but it was significant higher for the Test group. After one and three months, an increase of this number was observed, however not reaching the initial levels for both groups. At the six months an increase almost equal to baseline levels in Test group was showed, while the Control group still similar to the three months results. The CFU of dark pigmented bacteria and the percentage values of patients with the studied bacteria, reduced after the treatment and returned to values close to the initial ones six months after the baseline for both groups. The VF, HF, CAL, PI and GI values reduced throughout the study, however with no difference between then, and for CEJGM distance an increase was noted throughout the study without significant difference between the groups. It was concluded that the Nd: YAG laser associated with scaling and root planning promoted bacterial reduction on class II furcation immediately after its application, although this reduction was not observed six months after and that both treatments promoted improvements of most clinical parameters throughout the study.
|
19 |
Avaliação in situ da associação do verniz fluoretado ao laser de Er:YAG e ao laser de Nd:YAG na permeabilidade da dentina radicular erodida / In Situ Evaluation of Associating the Fluoride Varnish to Er:YAG or Nd:YAG Laser at permeability of eroded root dentin.Mariana Alencar Nemezio 04 June 2013 (has links)
O objetivo do presente estudo foi avaliar in situ o efeito da associação do verniz fluoretado ao laser de Er:YAG e ao laser Nd:YAG na permeabilidade da dentina radicular erodida. Quarenta e oito fragmentos de dentina radicular bovina, com dimensões 2x2x2 mm, foram submetidos a um desafio erosivo inicial com ácido cítrico (0,3%, pH 3,2), por duas horas, sob agitação e armazenados em saliva artificial por vinte e quatro horas. Posteriormente, os espécimes foram divididos em relação aos tratamentos: verniz fluoretado e não fluoretado e subdivididos conforme a irradiação: laser de Er:YAG (100mJ, 3Hz), laser de Nd:YAG (70mJ, 15 Hz) e não irradiado. Após um período de lead in (2 dias), os voluntários (n=8) utilizaram dispositivos palatinos contendo três espécimes que foram submetidos a desafios erosivos ex vivo, quatro vezes ao dia, com ácido cítrico (0,3%, pH 3,2), durante 90s, por cinco dias. Na primeira fase do experimento, metade dos voluntários utilizou dispositivos contendo fragmentos tratados com verniz fluoretado, verniz fluoretado + laser de Er:YAG e verniz fluoretado + laser de Nd:YAG. A outra metade utilizou verniz não fluoretado, verniz não fluoretado + laser de Er:YAG e verniz não fluoretado + laser de Nd:YAG. Depois de um período de wash-out (15 dias), os voluntários foram cruzados quanto aos tratamentos, caracterizando um experimento cross-over 2x2. Ao final de cada fase experimental, a permeabilidade dentinária foi avaliada. A ANOVA dois critérios e o teste complementar de Duncan revelaram uma diferença significativa entre os espécimes tratados com o verniz fluoretado (p=0,005), verniz fluoretado + laser de Er:YAG (p=0,014) e verniz fluoretado + laser de Nd:YAG (p=0,025), em comparação aos tratados com verniz não fluoretado. Observou-se que, independentemente da associação aos lasers (Er:YAG ou Nd:YAG), o verniz fluoretado foi capaz de promover a redução da permeabilidade da dentina radicular erodida. Não se observou efeito adicional com a associação dos tratamentos. / The present study aimed to evaluate in situ the effect of associating the fluoride varnish to Er:YAG or Nd:YAG laser at permeability of eroded root dentin. Forty-eight specimens of bovine root dentin (2x2x2mm) were subjected to initial erosive challenge with citric acid (0.3%, pH 3.2), for 2 hours under agitation and stored at artificial saliva, at 37° C, for 24 hours, followed by a remineralization period in artificial saliva. After that, specimens were divided according to the treatment: fluoride varnish and non-flouride varnish, and subdivided according to the irradiation: Er:YAG laser (100mJ, 3Hz), Nd:YAG laser (70mJ, 15Hz) and non-irradiated. After a lead-in period (2 days), 8 volunteers (n=8) wore a palatal device containing 3 specimens that was subjected to erosive challenges ex vivo, four times a day with citric acid (0.3%, pH3.2), for 90s, during 5 days. At the first experimental phase, half of volunteers wore devices containing specimens treated with fluoride varnish, fluoride varnish + Er:YAG laser and fluoride varnish + Nd:YAG laser, and the other half wore the specimens treated with non-fluoride varnish, non-fluoride varnish + Er:YAG laser and non-flouride varnish + Nd:YAG laser. After a wash-out period (15 days), volunteers were crossed to different treatment, characterizing a 2x2 cross-over experiment. At the end of each experimental phase, the dentinal permeability was evaluated. Two-way ANOVA and Duncans test revealed a significant difference between specimens treated with fluoride varnish (p=0,005), fluoride varnish + Er:YAG laser (p=0,014) and fluoride varnish + Nd:YAG (p=0,025) compared to specimens treated with no-fluoride varnish. It was observed that regardless of association to laser (Er:YAG or Nd:YAG), fluoride varnish was able to promote, in situ, the reduction of permeability of eroded root dentin, but no additional effect was observed when the treatments were associated.
|
20 |
Avaliação in vitro da resistência adesiva e degradação da interface de união entre cimentos resinosos e uma cerâmica aluminizada tratada internamente com laser / In Vitro analsis of bond strength and degradation method between bond interface of aluminous ceramic and resin cementsBruno Lopes da Silveira 04 July 2008 (has links)
O estudo teve o objetivo de avaliar a resistência adesiva e a degradação da interface entre uma cerâmica tratada com laser e cimentos resinosos. Sessenta e quatro blocos cerâmicos foram distribuídos em 16 grupos distribuídos de acordo com os fatores em estudo: tratamento da superfície interna da cerâmica: Oxido de Alumínio (Ox), Rocatec (R), Laser de Nd:YAG 141,54 J/cm2 (Nd) e Laser de Nd:YAG + Rocatec (NdR); cimentos resinosos: Panavia F (Kuraray) e Relyx Unicem (3M ESPE); e método de envelhecimento: água destilada (W) e hipoclorito de sódio 10% (H). Após os procedimentos de cimentação e corte dos blocos, metade dos palitos foi armazenada em solução de hipoclorito de sódio 10% para simular envelhecimento in vitro. A resistência de união foi avaliada através do ensaio de microtração (0,5 mm/min) e os padrões de fratura foram classificados em adesivo, coesivo ou misto. Blocos cerâmicos adionciais foram confeccionados e analisados em Microscopia Eletrônica de Varredura e em Microscópio de Força Atômica para verificação dos padrões gerados pelos tratamentos. Os grupos tratados com laser de Nd:YAG apresentaram os maiores valores de resistência de união. Para os grupos cimentados com Panavia F, os valores de resistência de união foram: OxW: 27,71±6,3; RW: 35,67±5,13; NdW: 42,49±6,8; NdRW: 37,41±4,76; OxH: 22,27±6,05; RH: 27,49±8,83; NdH: 32,24±6,94; NdRH: 31,75±7,77. Para os grupos com RelyX Unicem: OxW: 26,74±6,34; RW: 35,07±6,02; NdW: 41,05±7,71; NdRW: 33,85±6,03; OxH: 22,77±7,37; RH: 27,84±6,26; NdH: 36,42±5,08; NdRH: 27,6±5,8. Pode-se concluir que o laser de Nd:YAG foi o tratamento mais efetivo, seguido da associação entre o laser de Nd:YAG+Rocatec, Rocatec e jateamento com Al2O3. Os cimentos testados apresentam comportamentos similares. O envelhecimento in vitro com hipoclorito de sódio diminuiu os valores de resistência de união. / The aim of this study was to evaluate the influence of different surface treatments on resistance to degradation between In-Ceram Alumina and two resin-based cements. Sixteen experimental groups were formed according to ceramic treatment: Sandblasting (S), Rocatec System (R), Nd:YAG Laser (Nd), Nd:YAG Laser plus Rocatec System (NR); luting cement: Panavia F (Kuraray) or Relyx Unicem (3M ESPE); and aging method: water (W) or sodium hypochlorite (H). Sixty four In-Ceram Alumina blocks (10x10x6mm) received four surface treatments: Al2O3 sandblasting; Al2O3 sandblasting + Rocatec Plus; Al2O3 sandblasting + Nd:YAG Lase; Al2O3 sandblasting + Nd:YAG Laser + Rocatec Plus. Each conditioned ceramic block was bonded to a composite block using a resin cement system. After 24h storage time, the blocks were sectioned to obtain sticks with cross-sectional area of 1.0mm2. The specimens were loaded to failure in a universal testing machine at a crosshead speed of 0.5mm/min. The fractured surface morphology of the debonded specimens was observed (40X) to evaluate the fracture pattern. Failure modes were classified as adhesive, cohesive in ceramic, cohesive in resin cement and mixed. The ceramic treatment and the aging method significantly affected the microtensile bond strength. Nd:YAG surface treatment resulted in the best bond strength values. To groups luted with Panavia F cement the microtensile bond strength values were: SW: 27,71±6,3; RW: 35,67±5,13; NdW: 42,49±6,8; NdRW: 37,41±4,76; SH: 22,27±6,05; RH: 27,49±8,83; NdH: 32,24±6,94; NdRH: 31,75±7,77. To groups luted with RelyX cement: SW: 26,74±6,34; RW: 35,07±6,02; NdW: 41,05±7,71; NdRW: 33,85±6,03; SH: 22,77±7,37; RH: 27,84±6,26; NdH: 36,42±5,08; NdRH: 27,6±5,8. Nd:YAG laser was the most effective surface treatment, followed by Nd:YAG+Rocatec, Rocatec and Al2O3 sandblasting. Resin cements presented similar behaviors in spite of aging. NaOCl 12h-immersion decreased Bond strength values.
|
Page generated in 0.0314 seconds