• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • 7
  • 1
  • Tagged with
  • 18
  • 18
  • 18
  • 10
  • 5
  • 5
  • 5
  • 5
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Cristalização epitaxial de ligas de SiGe sobre GaAs por laser pulsado

Origo, Fabio Dondeo 28 May 2004 (has links)
Orientador: Ivan E. Chambouleyron / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-08-03T23:11:41Z (GMT). No. of bitstreams: 1 Origo_FabioDondeo_D.pdf: 2612005 bytes, checksum: 49cccd9932debc21d33d8d86b82f22d2 (MD5) Previous issue date: 2004 / Resumo: Neste trabalho se estudou pela primeira vez a cristalização e a epitaxia por laser pulsado para a obtenção de filmes de SixG e1-x(x = 0, 0.1, 0,25, 0,5, 0,75 e 1) sobre substratos de GaAs. Foram utilizados pulsos de laser de Nd:Yag ¿ l =532 nm ¿ com duração de 7ns e spot size de 2 a 3 mm. Camadas ou multicamadas amorfas de Ge, Si ou SiGe foram depositadas por , Ion Beam Sputtering sobre substratos epiready e não epiready de GaAs (100) à temperatura de 200 ºC. A espessura total dos filmes depositados era da ordem de 100 nm. Mostramos a eficácia da remoção de óxidos superficiais do GaAs (Ga2O3, As2O3 e As2O5) e contaminantes (C) através do bombardeamento do GaAs por feixe de H2+ (30 eV) após aquecimento a 350ºC. Demonstramos que filmes de a-Si0.1Ge0.9:H depositados com gás Kr são mais compactos que aqueles produzidos com Ar devido ao efeito de bombardeamento por partículas refletidas no alvo e por essa razão todos os filmes preparados para cristalização foram produzidos com Kr. Após irradiação com pulso entre 70 e 170 mJ, os filmes de Ge depositados sobre GaAs foram completamente liquefeitos por intervalo de até 20 ns e foram cristalizados. Dentro da área irradiada, quatro regiões foram identificadas, em ordem crescente da fluência ¿F- do laser: A) material que permaneceu amorfo (F<400 mJ/cm2), B) região policristalina (400 mJ/cm2 <F<900 mJ/cm2 ), C) região epitaxial com pouca mistura com o substrato (900 mJ/cm 2 <F<1100 mJ/cm2 ), região epitaxial com muita mistura (1100 mJ/cm2 <F<1300 mJ/cm2). O bombardeamento de uma certa região por múltiplos pulsos gera aumento da mistura com o substrato e a cristalização na forma policristalina. Os filmes multicamadas Si/Ge foram uniformemente misturados após a irradiação do laser, se transformando em filmes de SixGe1-x, com a composição esperada (x=0,25, 0,50, 0,75). Os filmes de SiGe cristalizados por laser apresentam as mesmas quatro regiões observadas em Ge. Observamos epitaxia para ligas com até 25% de Si. Para x=0,5 o material resultante é policristalino com grãos seguindo preferencialmente a orientação do substrato. Para maiores valores de x o material resultante é policristalino / Abstract: In this work we studied, for the first time, the pulsed laser crystallization and epitaxy of SixGe1-x films (x = 0, 0.1, 0,25, 0,5, 0,75 and 1) on GaAs substrates. Nd:Yag laser pulses ( g =532 nm), 7 ns wide and 2 to 3 mm spot size, were applied. Amorphous layers and multilayers of Ge, Si or SiGe were deposited, by Ion Beam Sputtering, on epiready and nonepiready GaAs (100) substrates at 200ºC. The total thicknesses are close to 100 nm. We have shown the efficacy of superficial oxide removal (Ga2O3, As2O3 and As2 O5) and contaminants (C) bombarding the substrate surface with H2+ beam (30 eV) after heating at 350ºC. We demonstrated that a-Si0.1Ge0.9:H films deposited with Kr are more compact than those produced with Ar due to the bombardment effect by particles reflected on the target; therefore, all the films prepared for laser crystallization were deposited with Kr. After laser irradiation with 70mJ-170 mJ pulses, the SiGe films were completely liquefied up to 20 ns and crystallized. Inside the irradiated area, four different regions were identified according to the increasing of laser fluency - F: A) amorphous material (F<400 mJ/cm2 ); B) polycrystalline material (400 mJ/cm2 <F<900 mJ/cm2 ); C) epitaxial material presenting low mixture with the substrate (900 mJ/cm2 <F<1100 mJ/cm2 ); D) epitaxial material presenting high mixture with the substrate (1100 mJ/cm2 <F<1300 mJ/cm2). The multiple irradiation of an area produces an increase in the mixture with the substrate components (Ga, As) and generates polycrystalline material. The Si/Ge multilayers were completely mixed after laser irradiation, forming SixGe1-x films with the expected composition (x=0,25, 0,50, 0,75).The SixGe1-x laser crystallized films present the same four regions as observed in Ge films. Epitaxial films were obtained for x up to 0,25. For x=0,5, crystallized films are polycrystalline with highly oriented grains. For higher Si content, laser crystallized SiGe films are polycrystalline / Doutorado / Física / Doutor em Ciências
12

Capsulotomia posterior unilateral : alterações de função e capacidade visual na vida diaria / Unilateral posterior capsulotomy: changes of visual function and visual ability in daily life

Senne, Firmani Mello Bento de 08 February 2006 (has links)
Orientador: Edmea Rita Temporini Nastari / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-07T02:25:27Z (GMT). No. of bitstreams: 1 Senne_FirmaniMelloBentode_D.pdf: 2133397 bytes, checksum: 05da70735ad5bd1022b72b3f03385933 (MD5) Previous issue date: 2006 / Resumo: Realizou-se um estudo transversal com intervenção com os objetivos de identificar a influência da capsulotomia posterior unilateral com Neodímio: Ítrio-Alumínio-Granada (Nd:YAG) laser na função visual e em relação à percepção de dificuldades nas atividades diárias, e verificar a relação entre as medidas subjetivas e objetivas da função visual após a intervenção. A amostra, prontamente acessível, foi composta por 48 pacientes entre 40 e 80 anos, média de 68 anos, mediana de 70 anos, pseudofácicos uni ou bilaterais, com opacificação de cápsula posterior e acuidade visual menor ou igual a 0,30 (logMAR) em um olho, atendidos consecutivamente em um hospital universitário no Brasil. Todos os pacientes foram submetidos a capsulotomia posterior com Nd:YAG laser. Um questionário, elaborado a partir de estudo exploratório, foi aplicado antes e depois da intervenção. Após a capsulotomia posterior, a acuidade visual e a estereoacuidade melhoraram significativamente. Na percepção dos sujeitos, houve redução das dificuldades relacionadas às atividades diárias ligadas à visão, exceto passar roupas, tomar banho sem ajuda e pentear os cabelos. As medidas objetivas e a auto-avaliação da visão apresentaram congruência de resultados e todos os pacientes declararam ter valido a pena a realização do procedimento laser / Abstract: An interventional survey was conducted to assess the influence of Neodymium: Yttrium-Aluminium-Garnet (Nd: YAG) laser unilateral posterior capsulotomy on visual function and perception of difficulties with vision-related daily life activities, and to verify the association between objective and subjective measures of visual function after intervention. The readily accessible sample comprised 48 patients aged between 40 and 80 years, with uni- or bilateral pseudophakia, posterior capsule opacification and visual acuity equal to or less than 0,30 (logMAR) in one eye, consecutively seen at a Brazilian university hospital. All the patients were submitted to posterior capsulotomy by Nd:YAG laser. Before and after intervention, patients were asked to answer a questionnaire developed from data obtained in an exploratory study. After posterior capsulotomy, visual acuity and stereoacuity improved significantly. According to the subjects' perception, they found less difficulty in vision-related daily activities, except for ironing, bathing without help and combing the hair. Objective measures of visual function and self-rated visual function showed congruent results after intervention. All the subjects interviewed stated that the posterior capsulotomy procedure had been ¿worthwhile¿ / Doutorado / Oftalmologia / Doutor em Ciências Médicas
13

Sapphire room temperature optical frequency reference : design, construction and application

Dawkins, Samuel T January 2008 (has links)
A pair of high-stability optical frequency references has been developed. The devices are based on room temperature Fabry-Perot cavities with mirrors spaced apart by a hollow single-crystal sapphire element. The sapphire element delivers mechanical sti ness that provides improved immunity to vibrational perturbations compared with the more common spacers made from ultra-low expansion glass. The system is housed in an vacuum chamber designed to provide isolation from environmental perturbations through the use of an active thermal control system, suspension legs and a unique beam alignment system. The dimensional stability of the Fabry-Perot was translated into a highly stable laser frequency by frequency locking a 1064nm Nd:YAG laser to the centre of a mode of the cavity. This frequency lock was implemented by the Pound-Drever-Hall scheme. By careful design, this control system was able to hold the frequency of the laser to within parts in 1016 of the frequency of the fundamental cavity mode. The minimum fractional frequency stability of the laser frequency was measured at 2.1x10[-]14 for integration times of 0.8 s, limited by the residual instability of the Fabry-Perot cavity. The experimental methods used to measure the performance of the system have also been considered in depth. For example, the most common way of characterizing the frequency stability of a frequency standard is the Allan variance. It is demonstrated that, without care, data taken with modern frequency counters can produce erroneous and distorted results when their output is supplied to this algorithm. The method to avoid or account for these errors is also presented. The Fabry-Perot cavity performance is limited on long timescales by residual temperature uctuations, which can be ameliorated in future by enhancing the design of the thermal control system. At short timescales, the system is limited by vibration-induced uctuations together with a white noise source, that is yet to be identi ed, but may relate to fundamental thermodynamic temperature uctuations of the sapphire spacer. This system was used to measure the stability of an optical signal synthesised from a cryogenic microwave sapphire oscillator using an wide-band optical frequency comb. This was the rst demonstration of a multiplication of an ultra-stable signal from the microwave frequency domain into the optical frequency domain, without loss of delity at the level of 2x10[-]14.
14

Ocorrência de opacidade de cápsula posterior em cães pós-facoemulsificação, com ou sem a utilização de lente intraocular dobrável e efeitos do Nd: Yag Laser

Conceição, Luciano Fernandes da [UNESP] 15 July 2014 (has links) (PDF)
Made available in DSpace on 2015-04-09T12:28:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-07-15Bitstream added on 2015-04-09T12:48:22Z : No. of bitstreams: 1 000814977.pdf: 648645 bytes, checksum: 30e76402fd013eac04392612d142190b (MD5) / A catarata elenca-se entre as afecções oculares mais freqüentes em cães, sendo a facoemulsificação o método que melhor se adequa à sua terapia. As opacidades de cápsula posterior (OCPs) estão entre as complicações mais comuns e se manifestam em semanas ou meses após a facectomia. Lentes intraoculares (LIOs), empregadas na correção da hipermetropia pós-cirúrgica, são citadas como úteis na prevenção das OCPs, especialmente as acrílicas dobráveis, com bordas truncadas ou quadradas. Entretanto, quando OCPs se estabelecem requerem-se capsulotomias como forma de tratamento. Em pacientes humanos, reconhecem-se os efeitos do Nd:YAG laser como técnica não invasiva e segura frente a tais intercorrências. Para se compararem resultados de olhos de cães que receberam lentes intraoculares acrílicas dobráveis com olhos de cães afácicos, após facoemulsificação, durante um período de 180 dias, utilizaram-se 20 cães de raças diversas, machos ou fêmeas, que variaram de 3 a 7 anos de idade, apresentando catarata juvenil , imatura ou madura (imatura n = 10 , madura n = 10) bilateral. Dois grupos (G1 = com implante de lente intraocular e G2 = sem implante de lente artificial) foram formados aleatoriamente e todos os cães tiveram ambos os olhos operados. Após a cirurgia, os pacientes foram avaliados, semanalmente, quanto a presença ou a ausência de sinéquias, discoria, pressão intraocular, inflamação uveal e presença ou não de opacidade de cápsula posterior durante um período de 180 dias. Aos 60, 90, 120, 150 e 180 dias após a cirurgia, imagens da cápsula posterior foram capturados para avaliação da sua opacidade. Olhos com score 2 ou 3 de opacidade foram submetidos à terapia de capsulotomia pelo Nd:YAG laser. Variáveis categóricas ordinais foram comparadas (G1 X G2) empregando-se o teste de qui-quadrado e o teste exato de Fisher. Variáveis quantitativas foram comparadas empregando-se ANOVA com pós teste de Tukey / Cataracts are among the most common eye diseases in dogs, being the phacoemulsification method the one that best suits in their therapy. The posterior capsule opacification (PCOs) are among the most common complications and manifest themselves in weeks or months after cataract surgery. Intraocular lenses (IOLs) used in the correction of postoperative hyperopia, are mentioned as useful in the prevention of PCOs , especially the foldable acrylic ones with truncated or square edges. However, when PCOs are set up, capsulotomies are required as a treatment. In human patients, the effects of the Nd:YAG laser are recognized as a noninvasive and secure technique against such problems. To compare the results of eyes of dogs that received foldable acrylic intraocular lenses with eyes of aphakic dogs, after phacoemulsification, during a period of 180 days it was used 20 dogs of several breeds, male or female , ranging from 3 to 7 years old , with juvenile, immature or mature (n = 10 immature, mature n = 10) bilateral cataracts . Two groups (G1 = with implantation of intraocular lens and G2 = no artificial lens implant) were randomly formed and all dogs had both eyes operated. After the surgery, the patients were weekly evaluated for the presence or absence of synechiae, discoria, intraocular pressure, uveal inflammation and presence or absence of posterior capsule opacification during a period of 180 days. At 60, 90, 120, 150 and 180 days after surgery, the posterior capsule images were captured for evaluation of their opacity. Eyes with score 2 or 3 of opacity were underwent to capsulotomy by Nd:YAG laser. Ordinal categorical variables were compared (G1 X G2) using the chi-square and Fisher´s exact test. Quantitative variables were compared using ANOVA with Tukey post test. Synechiae were observed in the same frequency in both groups .G2 showed 30 % more discoria when compared to G1 Intraocular pressure did not differ between the groups. The ...
15

Ocorrência de opacidade de cápsula posterior em cães pós-facoemulsificação, com ou sem a utilização de lente intraocular dobrável e efeitos do Nd: Yag Laser /

Conceição, Luciano Fernandes da. January 2014 (has links)
Orientador: José Luiz Laus / Banca: Adriana Morales / Banca: João Antônio Tadeu Pigatto / Banca: Paola Castro Moraes / Banca: Luis Gustavo Gosuen Gonçalves Dias / Resumo: A catarata elenca-se entre as afecções oculares mais freqüentes em cães, sendo a facoemulsificação o método que melhor se adequa à sua terapia. As opacidades de cápsula posterior (OCPs) estão entre as complicações mais comuns e se manifestam em semanas ou meses após a facectomia. Lentes intraoculares (LIOs), empregadas na correção da hipermetropia pós-cirúrgica, são citadas como úteis na prevenção das OCPs, especialmente as acrílicas dobráveis, com bordas truncadas ou quadradas. Entretanto, quando OCPs se estabelecem requerem-se capsulotomias como forma de tratamento. Em pacientes humanos, reconhecem-se os efeitos do Nd:YAG laser como técnica não invasiva e segura frente a tais intercorrências. Para se compararem resultados de olhos de cães que receberam lentes intraoculares acrílicas dobráveis com olhos de cães afácicos, após facoemulsificação, durante um período de 180 dias, utilizaram-se 20 cães de raças diversas, machos ou fêmeas, que variaram de 3 a 7 anos de idade, apresentando catarata juvenil , imatura ou madura (imatura n = 10 , madura n = 10) bilateral. Dois grupos (G1 = com implante de lente intraocular e G2 = sem implante de lente artificial) foram formados aleatoriamente e todos os cães tiveram ambos os olhos operados. Após a cirurgia, os pacientes foram avaliados, semanalmente, quanto a presença ou a ausência de sinéquias, discoria, pressão intraocular, inflamação uveal e presença ou não de opacidade de cápsula posterior durante um período de 180 dias. Aos 60, 90, 120, 150 e 180 dias após a cirurgia, imagens da cápsula posterior foram capturados para avaliação da sua opacidade. Olhos com score 2 ou 3 de opacidade foram submetidos à terapia de capsulotomia pelo Nd:YAG laser. Variáveis categóricas ordinais foram comparadas (G1 X G2) empregando-se o teste de qui-quadrado e o teste exato de Fisher. Variáveis quantitativas foram comparadas empregando-se ANOVA com pós teste de Tukey / Abstract: Cataracts are among the most common eye diseases in dogs, being the phacoemulsification method the one that best suits in their therapy. The posterior capsule opacification (PCOs) are among the most common complications and manifest themselves in weeks or months after cataract surgery. Intraocular lenses (IOLs) used in the correction of postoperative hyperopia, are mentioned as useful in the prevention of PCOs , especially the foldable acrylic ones with truncated or square edges. However, when PCOs are set up, capsulotomies are required as a treatment. In human patients, the effects of the Nd:YAG laser are recognized as a noninvasive and secure technique against such problems. To compare the results of eyes of dogs that received foldable acrylic intraocular lenses with eyes of aphakic dogs, after phacoemulsification, during a period of 180 days it was used 20 dogs of several breeds, male or female , ranging from 3 to 7 years old , with juvenile, immature or mature (n = 10 immature, mature n = 10) bilateral cataracts . Two groups (G1 = with implantation of intraocular lens and G2 = no artificial lens implant) were randomly formed and all dogs had both eyes operated. After the surgery, the patients were weekly evaluated for the presence or absence of synechiae, discoria, intraocular pressure, uveal inflammation and presence or absence of posterior capsule opacification during a period of 180 days. At 60, 90, 120, 150 and 180 days after surgery, the posterior capsule images were captured for evaluation of their opacity. Eyes with score 2 or 3 of opacity were underwent to capsulotomy by Nd:YAG laser. Ordinal categorical variables were compared (G1 X G2) using the chi-square and Fisher's exact test. Quantitative variables were compared using ANOVA with Tukey post test. Synechiae were observed in the same frequency in both groups .G2 showed 30 % more discoria when compared to G1 Intraocular pressure did not differ between the groups. The ... / Doutor
16

Processo de deposição e propriedades de filmes de dióxido de titânio obtidos por "laser ablation"

Damião, Alvaro Jose 13 August 2002 (has links)
Orientador: Mario Antonio Bica de Moraes / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-08-02T03:15:36Z (GMT). No. of bitstreams: 1 Damiao_AlvaroJose_D.pdf: 7111682 bytes, checksum: a021d57bfd78393326cd15212c4cae6d (MD5) Previous issue date: 2002 / Resumo: Este trabalho descreve os estudos do processo de deposição a laser de TiO2, assim como algumas propriedades dos alvos utilizados e dos filmes depositados. O objetivo era a obtenção de filmes para serem utilizados como elemento de composição em componentes ópticos de precisão. Foram utilizados três diferentes lasers pulsados: CO2, Nd:YAG e Vapor de Cobre, oscilando nos comprimentos de onda tradicionais, ou seja, sem dobrar freqüências de emissão. A taxa de repetição dos lasers variou de 1 Hz para o laser de CO2 até 18 kHz para o laser de vapor de co-bre. Os lasers e a câmara de evaporação foram desenvolvidos no Instituto de Estudos Avançados IEAv - CTA, onde os trabalhos de deposição foram realizados. A espessura dos filmes depositados foi obtida por três processos diferentes: balança, osci-lador/cristal de quartzo e interferometria, a fim de verificar se havia influência do processo de de-posição no comportamento do cristal de quartzo. Como não houve influência, foram obtidos então os resultados de taxa de deposição, como função do tempo para diferentes condições de deposi-ção. Os alvos foram tratados termicamente, para verificar a influência do material de partida, não tendo sido observadas diferenças nos filmes obtidos. Os filmes foram caracterizados por téc-nicas ópticas (Método do Envelope), difração de raios X, XPS e microscopia eletrônica de varre-dura. Foram obtidos filmes uniformes, aparentemente sem os defeitos normalmente causados pela deposição a laser. Os filmes, como depositados, apresentaram alguma absorção, o que invia-biliza a sua utilização sem tratamento térmico / Abstract: This work presents the results of a laser deposition process of TiO2, target and thin film properties. The aim was to obtain thin films to be part of a multilayer coating for precision optical components. Three different pulsed lasers were used to deposit the films: CO2, Nd:YAG and Copper Vapor Lasers, LVC, all of them oscillating in their natural modes, i.e., without any apparatus to double the emission frequency. The repetition rate of the laser was as low as 1 Hz for CO2 and as high as 18kHz for LVC. The evaporation chamber and the lasers were developed at the Instituto de Estudos Avançados, IEAv-CTA, where the films were deposited. Mass measurement, quartz crystal oscillator and interferometry evaluated the films thick-ness, to check if the deposition process could affect the results obtained by the crystal oscillator. As no influence was detected, the crystal oscillator was used to measure the deposition rate of the films, as function of time, for different deposition conditions. The targets received a thermal treatment, to verify the influence of starting materials on the obtained films. The films were analyzed by Envelop Method (optical properties), X-ray, XPS and SEM. Uniform films were obtained, without the defects normally found when using laser deposi-tion. Films deposited at room temperature (as deposited) presented some absorption, which obliges the use of thermal treatment / Doutorado / Física / Doutor em Ciências
17

Laser surface hardening of AISI 1518 alloy steel

Zhang, Tao January 2010 (has links)
The laser surface hardening process will enhance the hardness profile of automotive components and ensure better process control and predictability of quality as compared to the conventional hardening processes. A 2KW Nd-YAG laser system was used to harden the surface of alloy steel with various process parameters (laser power, focal spot diameter and beam velocity). The results (microhardness, microstructure change and residual stress distribution) were measured and analyzed with Vickers microhardness tester, optical/electron microscope and hole-drilling residual stress equipment. Statistical analyses of the experimental data were used for explaining the relationships between process parameters, microhardness and microstructure. General thermal hardening was applied in the research to show the influence of heating temperature and cooling method on microstructure and mechanical properties. Also, the results were compared with laser surface hardening process from microhardness, microstructure and residual stress to show the advantage of laser surface hardening. Through analysis of the results of the laser surface hardening experiments, a suitable laser power density and interaction time for optimum hardening was obtained. The presented laser surface hardening process can also be applied to other alloy steel surface hardening process.
18

Influência de aplicações do laser érbio:YAG sobre a viabilidade microbiana, sua resistência a drogas e atividade hemolítica

Lopes, Angélica Marquezim [UNESP] January 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2003Bitstream added on 2014-06-13T19:57:14Z : No. of bitstreams: 1 lopes_am_me_araca.pdf: 932429 bytes, checksum: 58f57b4ef355fad92340a3819101663b (MD5) / A atividade antimicrobiana do laser Er:YAG foi avaliada sobre biofilme bacteriano constituído por Escherichia coli ATCC 8739, Escherichia coli ATCC 25922, Staphylococcus aureus ATCC 6538 e 3 cepas de Fusobacterium nucleatum e sobre biofilme de microrganismos salivares. Os biofilmes foram submetidos à ação do laser a 1,2 W e 10 Hz por 5, 10, 15, 20, 30 e 60 s e fez-se a avaliação da microbiota residual em ágar sangue, em anaerobiose. O biofilme salivar se mostrou mais sensível nos primeiros tempos de irradiação. A redução microbiana em relação ao controle foi estatisticamente significativa entre todos os tempos testados. Avaliou-se também a ação do laser Er:YAG sobre 7 cepas de Fusobacterium nucleatum inoculadas sobre a superfície de corpos-de-prova (5mmX4mm) de dentes extraídos. Fez-se a aplicação do laser nos mesmos parâmetros físicos mencionados anteriormente, durante 15 s, levando à eliminação total do conteúdo séptico. O estudo avaliou também a irradiação do laser de Er:YAG durante tempos subinibitórios sobre a atividade hemolítica e susceptibilidade de 9 cepas de Fusobacterium nucleatum a amoxicilina, eritromicina, metronidazol e tetraciclina. Após a irradiação do laser, determinou-se a concentração inibitória mínima (CIM) para as drogas através do método de diluição em ágar. A ação do laser sobre a atividade hemolítica foi determinada em sangue humano. Verificou-se que o laser Er:YAG não afetou a atividade hemolítica de Fusobacterium nucleatum, que se mostrou α-hemolítica, tampouco a susceptibilidade a drogas dos isolados testados. / Antimicrobial activity of Er:YAG laser was evaluated on a bacterial biofilm constituted by Escherichia coli ATCC 8739, Escherichia coli ATCC 25922, Staphylococcus aureus ATCC 6538 and 3 strains of Fusobacterium nucleatum and on biofilm produced by salivary microorganisms. Biofilms were irradiated by Er:YAG laser, 1,2 W and 10 Hz, for 5, 10, 15, 20, 30, and 60 s and the evaluation of residual contamination was performed on blood agar, under anaerobiosis. It was verified that salivary biofilm showed to be more susceptibility to the Er:YAG laser in shorter periods of laser irradiation. Bacterial reduction was significative in all tested periods of irradiation. The activity of Er:YAG laser was also evaluated on 7 strains of Fusobacterium nucleatum inoculated on samples of human dentin (5mm X 4mm), obtained from extracted teeth. The laser was used following the same physical parameters, as previously described, for 15 s, leading to complete elimination of their septic content. The study also evaluated the effects of subinibitory irradiation of Er:YAG laser on bacterial susceptibility of 9 strains of Fusobacterium nucleatum to antimicrobial drugs (amoxicillin, erythromycin, metronidazole, tetracycline) and hemolysis. Thus, after laser irradiation, the minimal inhibitory concentration of antimicrobial drugs was determined by using an agar dilution method. The influence of laser on hemolysis was carried out on human blood. It was verified that Er:YAG laser did not produce any measurable effect on hemolytic activity and the microbial susceptibility to tested antimicrobial drugs.

Page generated in 0.1151 seconds