Spelling suggestions: "subject:"anitrogen anda phosphorus removal"" "subject:"anitrogen ando phosphorus removal""
1 |
Using Tall Fescue to Remove Nutrients from Renovated Turkey Processing WastewaterXu, Jie 08 August 2013 (has links)
No description available.
|
2 |
Remoção de nitrogênio e fósforo de efluentes da atividade piscícola em sistema fechado utilizando reatores de leito móvel com biofilme / Removal of nitrogen and phosphorus from effluent from the closed-fishery system using moving bed biofilm reactorsEnriquez, Yemall Alexander Maigual 02 March 2018 (has links)
Submitted by YEMALL ALEXANDER MAIGUAL ENRIQUEZ (alex.feisunesp@gmail.com) on 2018-05-08T00:18:49Z
No. of bitstreams: 1
TESE MBBR-ICT-7-MAY-2018.pdf: 5856438 bytes, checksum: f1c36146463af4ee146d48da7c3be308 (MD5) / Approved for entry into archive by Bruna Bacalgini null (bruna@sorocaba.unesp.br) on 2018-05-08T14:17:18Z (GMT) No. of bitstreams: 1
enriquez_yam_dr_soro.pdf: 5856438 bytes, checksum: f1c36146463af4ee146d48da7c3be308 (MD5) / Made available in DSpace on 2018-05-08T14:17:18Z (GMT). No. of bitstreams: 1
enriquez_yam_dr_soro.pdf: 5856438 bytes, checksum: f1c36146463af4ee146d48da7c3be308 (MD5)
Previous issue date: 2018-03-02 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A aquicultura é uma atividade de produção de espécies hidrobiológicas sob condições controladas. Esta atividade tem evoluído nos processos produtivos, mas estão gerando águas residuárias, quando lançadas diretamente nos corpos de água constituindo riscos potenciais à saúde. O reator de leito móvel com biofilme (MBBR) é uma variação do processo de lodos ativados. É um sistema de tratamento de efluentes que contem biofilme que cresce aderida aos suportes, que se movem livremente no volume do reator. O objetivo desta pesquisa foi determinar a eficiência na remoção de material, nitrogenado no MBBR dos efluentes gerados num sistema de recirculação para aquicultura “SRA”. O sistema MBBR com circulação (SC) - e com aeração (SA) obteve remoções medias de 38,7% para Nitrogênio Total Kjedahl (NTK), 28,9% de fósforo total, 44,5% de DBO, Nitrogênio Amoniacal Total (NAT) de 40% e 38,9% para amônia não ionizada e para nitrito foi 59,3%. Os sólidos Totais (ST), Sólidos Suspensos Totais (SST) e Sólidos Voláteis Totais (SVT) tiveram remoções de 28,0%, 45,9% e 57,4% respectivamente. Durante o período avaliado houve aumento do biofilme nos dois reatores. No MBBR-SA foi verificada a presença de protozoários, microinvertebrados e estruturas filamentosas semelhantes a estreptococos. No MBBR-SC, bactérias na forma de cocos, diplococos e estreptococos. Nas analises realizadas com MEV nos lodos dos dois sistemas foi encontrado traços de silício, alumínio, zinco, fósforo, sódio e magnésio. Também foi encontrado bactérias do tipo vibrio spp, bacilus spp, além da formação de aglomerados. As analises térmicas feitas nos lodos indicaram que houve perda de umidade até os 150°C. A maior parte da massa se perde entre 220°C e 580°C, faixa onde sofrem transformação térmica as proteínas, lipídeos, carboidratos, ácidos graxos, restos de paredes celulares bacterianas. Após os 600°C existe o restante, as cinzas são compostas por carbonatos e outros minerais transformando-se em matérias cristalinos, com baixa variação na massa. / Aquaculture is an activity of production of hydrobiological species under controlled conditions. These activities have evolved in the productive processes, but are producing wastewater, when thrown directly into bodies of water constituting potential health risks. The moving bed biofilm reactor (MBBR) is a variation of the activated sludge process. It is an effluent treatment system containing biofilm growing attached to the carriers, which move freely in the reactor volume. The aim of this research was to determine the efficiency in the removal of nitrogenous compounds in MBBR from the effluents generated in a recirculating aquaculture system "RAS". The MBBR system with circulation (CS) - and with aeration (AS) obtained mean removals of 38.7% for NTK, 28.9% of total phosphorus, 44.5% of BOD, 40% TAN and 38.9% for non-ionized ammonia and for nitrite was 59.3%. Total Solids (TS), Total Suspended Solids (TSS) and Total Volatile Solids (TSV) had removals of 28.0%, 45.9% and 57.4% respectively. During the evaluated period there was an increase of biofilm in the two reactors. In the MBBR-AS the presence of protozoa, microinvertebrates and filamentous structures similar to streptococcus was verified. Also, in MBBR-CS was verified coccus, diplococcus and streptococcus bacteria. In the analyzes performed with SEM in the sludge of the two systems, traces of silicon, aluminum, zinc, phosphorus, sodium and magnesium. Vibrio and bacillus type bacteria were present and besides granule formation. Thermal analyzes indicated that there was in the sludge moisture loss until 150°C. Most of the mass is loss between 220°C and 580°C, where they undergo thermal transformation of proteins, lipids, carbohydrates, fatty acids, remains of bacterial cell walls. After the 600°C the ashes are composed of carbonates and other minerals transforming into crystalline materials, with low mass variation. / CAPES: 12616-13-3
|
3 |
Desempenho de um reator aeróbio de leito fluidizado no tratamento de esgoto sanitário. / Performance of an aerobic fluidized bed reactor in sanitary sewage treatment.Gebara, Dib 17 May 2006 (has links)
Apresenta-se a investigação experimental do tratamento de esgoto sanitário, submetido apenas a gradeamento, por meio de reatores aeróbios de leito trifásico com circulação em tubos concêntricos induzida por injeção de ar. Foram construídos dois reatores com 0,25m de diâmetro externo, 0,20m de diâmetro interno e alturas de 6m (R6) e 12m (R12). O meio suporte utilizado (fase sólida) foi areia com 0,27mm de diâmetro médio. Os tempos de detenção hidráulica investigados variaram entre 1,0h e 8,0h, com concentração de sólidos de 50g/l e 100g/l. Nas etapas iniciais do trabalho houve a necessidade de vazões de ar da ordem de 6000 l/h para manter o meio em suspensão, introduzindo uma quantidade de oxigênio superior ao necessário para o tratamento. Para diminuir a vazão de ar foi utilizado um propulsor axial no tubo de subida para auxiliar a circulação do meio trifásico, o que permitiu reduzir as vazões de ar para cerca de 3500 l/h. Os melhores resultados desta fase foram obtidos com TDH = 3h e 100g/l de areia. As remoções médias de DBO bruta, e filtrada, DQO bruta e filtrada e NTK foram de 89%, 99%, 84%, 95% e 87%, respectivamente, para o R12 e de 89%, 98%, 82%, 95% e 86%, respectivamente, para o R6, sem diferenças estatisticamente significativas entre os reatores. As remoções médias de fósforo total para os reatores R12 e R6 com TDH = 3h foram 31% e 32%.Entretanto, foi produzida uma parcela de sólidos em suspensão de baixa sedimentabilidade, que prejudicava a qualidade do efluente final. As soluções investigadas para este problema foram a utilização de uma câmara de flotação no R12 e a diminuição do diâmetro do tubo de subida, implantada no R6. Ambos os reatores foram ensaiados com TDH = 3h e 100g/l de areia. O sistema de flotação foi avaliado com taxas de recirculação de 15% e 20%. O efluente final resultante ainda continha uma parcela indesejável de biomassa suspensa. A remoção média de fósforo total durante essa etapa foi de 42 %. De forma geral não houve melhorias estatisticamente significativas na operação do flotador na remoção de fósforo e nos demais parâmetros avaliados. Entretanto ensaios em laboratório mostraram que com a adição de 75 mg/l de Cloreto Férrico a remoção de fósforo total aumentou para 87 %. A redução do diâmetro do tubo interno no R6 permitiu diminuir as vazões iniciais para 1500 l/h sem problemas de suspensão do leito, sendo posteriormente aumentado para 2100 l/h por exigência do tratamento biológico. As remoções médias de DQO e DBO brutas, NT, e Fósforo Total situaram-se em 91%, 88%, 72% e 32% respectivamente. O reator apresentou bom desempenho hidrodinâmico, melhorando os problemas de sedimentabilidade do lodo e as características físicas do efluente. A pesquisa mostra que a solução de leito trifásico com circulação é tecnicamente viável para o tratamento de esgoto sanitário submetido apenas a gradeamento. A câmara de flotação integrada mostrou-se tão eficiente quanto os decantadores, com a vantagem de permitir aumento significativo na remoção de fósforo com a adição de floculantes. Os dados demonstraram também que é possível controlar as condições hidrodinâmicas para a produção de lodo com melhor sedimentabilidade e para otimizar a necessidade de injeção de ar, atuando sobre a relação entre os diâmetros interno e externo. Os aspectos econômicos envolvidos na utilização eficiente do ar constituem a principal necessidade de pesquisa visando à adoção da tecnologia para a utilização proposta. / The experimental investigation of the sanitary sewage treatment, submitted only to screening, through three-phase bed aerobic reactors with circulation in concentric tubes induced by air injection, is presented. Two reactors had been constructed, with 0.25 m external diameter, 0.20 m internal diameter, and 6m (R6) and 12m (R12) high, respectively. The support medium (solid phase) was sand with 0.27 mm medium diameter. The hydraulic detention times investigated ranged between 1.0 h and 8.0 h, with solid concentrations of 50 g/l and 100 g/l. At the initial stages of the research, the reactors needed to work with air outflow of 6000 l/h, to maintain the support medium suspended, introducing an oxygen quantity higher than the necessary to the treatment. To reduce the air outflow, an axial propeller had been used at the ascent tube to aid the circulation, allowing to reduce the air outflows to about 3500 l/h. The best results for this stage had been obtained with HDT = 3h and 100g sand/l. The averaged removal of rough and filtered BOD, rough and filtered COD, and TKN for the R12 were 89%, 99%, 84%, 95%, and 87%, respectively. For the R6 the values were 89%, 98%, 82%, 95%, and 86%, respectively, without statistically significant differences between the R6 and R12. The averaged total phosphorus removal for R12 and R6 were 31 and 32%, with HDT = 3h. However, a low sedimentability portion of suspending solids had been produced, which prejudiced the final effluent quality. The solutions investigated to solve this problem were a flotation chamber in the R12 and the reduction of the ascent tube diameter, in the R6. Both reactors had been analyzed with HDT = 3h and 100g sand/l. The flotation system had been analyzed with recirculation rate of 15% and 20%. The final effluent still contained an undesired suspended biomass portion. The medium total phosphorus removal during this stage was 42%. Generally, there was no statistically significative improvements at the flotation tank operation in the phosphorus removal and others evaluated parameters. Laboratory assays, however, showed that adding 75 mg ferric chloride, the total phosphorus removal increased to 87%. The intern tube diameter reduction at the R6 diminished the initial outflow to 1500 l/h, without bed suspension problems. The outflow was later increased to 2100 l/h, due to the biological treatment. The medium removal of CDO, BOD, NT ant total phosphorus were 91%, 88%, 72%, and 32%, respectively. The reactor presented good hydrodynamic performance, improving the sedimentability problems of the sludge and the effluent physical characteristics. The research shows that the triphasic bed with circulation solution is technically feasible for the sanitary sewerage treatment submitted only to screening. The integrated flotation chamber was as efficient as the sedimentations tanks, with the advantage of to allow significative increase in the phosphorus removal with coagulants addition. The data also shown that it is possible to control the hydrodynamic conditions to produce sludge with better sedimentability and to optimize the air injection necessity, influencing the relation between the internal and the external diameters. The economical aspects involved in the efficient use of the air constitutes the principal research necessity, aiming the adoption of the technology to the proposed use.
|
4 |
Desempenho de um reator aeróbio de leito fluidizado no tratamento de esgoto sanitário. / Performance of an aerobic fluidized bed reactor in sanitary sewage treatment.Dib Gebara 17 May 2006 (has links)
Apresenta-se a investigação experimental do tratamento de esgoto sanitário, submetido apenas a gradeamento, por meio de reatores aeróbios de leito trifásico com circulação em tubos concêntricos induzida por injeção de ar. Foram construídos dois reatores com 0,25m de diâmetro externo, 0,20m de diâmetro interno e alturas de 6m (R6) e 12m (R12). O meio suporte utilizado (fase sólida) foi areia com 0,27mm de diâmetro médio. Os tempos de detenção hidráulica investigados variaram entre 1,0h e 8,0h, com concentração de sólidos de 50g/l e 100g/l. Nas etapas iniciais do trabalho houve a necessidade de vazões de ar da ordem de 6000 l/h para manter o meio em suspensão, introduzindo uma quantidade de oxigênio superior ao necessário para o tratamento. Para diminuir a vazão de ar foi utilizado um propulsor axial no tubo de subida para auxiliar a circulação do meio trifásico, o que permitiu reduzir as vazões de ar para cerca de 3500 l/h. Os melhores resultados desta fase foram obtidos com TDH = 3h e 100g/l de areia. As remoções médias de DBO bruta, e filtrada, DQO bruta e filtrada e NTK foram de 89%, 99%, 84%, 95% e 87%, respectivamente, para o R12 e de 89%, 98%, 82%, 95% e 86%, respectivamente, para o R6, sem diferenças estatisticamente significativas entre os reatores. As remoções médias de fósforo total para os reatores R12 e R6 com TDH = 3h foram 31% e 32%.Entretanto, foi produzida uma parcela de sólidos em suspensão de baixa sedimentabilidade, que prejudicava a qualidade do efluente final. As soluções investigadas para este problema foram a utilização de uma câmara de flotação no R12 e a diminuição do diâmetro do tubo de subida, implantada no R6. Ambos os reatores foram ensaiados com TDH = 3h e 100g/l de areia. O sistema de flotação foi avaliado com taxas de recirculação de 15% e 20%. O efluente final resultante ainda continha uma parcela indesejável de biomassa suspensa. A remoção média de fósforo total durante essa etapa foi de 42 %. De forma geral não houve melhorias estatisticamente significativas na operação do flotador na remoção de fósforo e nos demais parâmetros avaliados. Entretanto ensaios em laboratório mostraram que com a adição de 75 mg/l de Cloreto Férrico a remoção de fósforo total aumentou para 87 %. A redução do diâmetro do tubo interno no R6 permitiu diminuir as vazões iniciais para 1500 l/h sem problemas de suspensão do leito, sendo posteriormente aumentado para 2100 l/h por exigência do tratamento biológico. As remoções médias de DQO e DBO brutas, NT, e Fósforo Total situaram-se em 91%, 88%, 72% e 32% respectivamente. O reator apresentou bom desempenho hidrodinâmico, melhorando os problemas de sedimentabilidade do lodo e as características físicas do efluente. A pesquisa mostra que a solução de leito trifásico com circulação é tecnicamente viável para o tratamento de esgoto sanitário submetido apenas a gradeamento. A câmara de flotação integrada mostrou-se tão eficiente quanto os decantadores, com a vantagem de permitir aumento significativo na remoção de fósforo com a adição de floculantes. Os dados demonstraram também que é possível controlar as condições hidrodinâmicas para a produção de lodo com melhor sedimentabilidade e para otimizar a necessidade de injeção de ar, atuando sobre a relação entre os diâmetros interno e externo. Os aspectos econômicos envolvidos na utilização eficiente do ar constituem a principal necessidade de pesquisa visando à adoção da tecnologia para a utilização proposta. / The experimental investigation of the sanitary sewage treatment, submitted only to screening, through three-phase bed aerobic reactors with circulation in concentric tubes induced by air injection, is presented. Two reactors had been constructed, with 0.25 m external diameter, 0.20 m internal diameter, and 6m (R6) and 12m (R12) high, respectively. The support medium (solid phase) was sand with 0.27 mm medium diameter. The hydraulic detention times investigated ranged between 1.0 h and 8.0 h, with solid concentrations of 50 g/l and 100 g/l. At the initial stages of the research, the reactors needed to work with air outflow of 6000 l/h, to maintain the support medium suspended, introducing an oxygen quantity higher than the necessary to the treatment. To reduce the air outflow, an axial propeller had been used at the ascent tube to aid the circulation, allowing to reduce the air outflows to about 3500 l/h. The best results for this stage had been obtained with HDT = 3h and 100g sand/l. The averaged removal of rough and filtered BOD, rough and filtered COD, and TKN for the R12 were 89%, 99%, 84%, 95%, and 87%, respectively. For the R6 the values were 89%, 98%, 82%, 95%, and 86%, respectively, without statistically significant differences between the R6 and R12. The averaged total phosphorus removal for R12 and R6 were 31 and 32%, with HDT = 3h. However, a low sedimentability portion of suspending solids had been produced, which prejudiced the final effluent quality. The solutions investigated to solve this problem were a flotation chamber in the R12 and the reduction of the ascent tube diameter, in the R6. Both reactors had been analyzed with HDT = 3h and 100g sand/l. The flotation system had been analyzed with recirculation rate of 15% and 20%. The final effluent still contained an undesired suspended biomass portion. The medium total phosphorus removal during this stage was 42%. Generally, there was no statistically significative improvements at the flotation tank operation in the phosphorus removal and others evaluated parameters. Laboratory assays, however, showed that adding 75 mg ferric chloride, the total phosphorus removal increased to 87%. The intern tube diameter reduction at the R6 diminished the initial outflow to 1500 l/h, without bed suspension problems. The outflow was later increased to 2100 l/h, due to the biological treatment. The medium removal of CDO, BOD, NT ant total phosphorus were 91%, 88%, 72%, and 32%, respectively. The reactor presented good hydrodynamic performance, improving the sedimentability problems of the sludge and the effluent physical characteristics. The research shows that the triphasic bed with circulation solution is technically feasible for the sanitary sewerage treatment submitted only to screening. The integrated flotation chamber was as efficient as the sedimentations tanks, with the advantage of to allow significative increase in the phosphorus removal with coagulants addition. The data also shown that it is possible to control the hydrodynamic conditions to produce sludge with better sedimentability and to optimize the air injection necessity, influencing the relation between the internal and the external diameters. The economical aspects involved in the efficient use of the air constitutes the principal research necessity, aiming the adoption of the technology to the proposed use.
|
Page generated in 0.1126 seconds