Spelling suggestions: "subject:"conformal"" "subject:"conormal""
1051 |
A 3% Measurement of the Beam Normal Single Spin Asymmetry in Forward Angle Elastic Electron-Proton Scattering using the Q<sub>weak</sub> SetupWaidyawansa, D. Buddhini P. 26 September 2013 (has links)
No description available.
|
1052 |
Modifying the target normal sheath accelerated ion spectrum using micro-structured targetsGeorge, Kevin Mitchell 23 May 2017 (has links)
No description available.
|
1053 |
FPGA Realization of Low Register Systolic Multipliers over GF(2^m)Shao, Qiliang January 2016 (has links)
No description available.
|
1054 |
Three-dimensional modeling of rigid pavementBeegle, David J. January 1998 (has links)
No description available.
|
1055 |
Essays in behavioral economics in the context of strategic interactionIvanov, Asen Vasilev 22 June 2007 (has links)
No description available.
|
1056 |
MgB<sub>2</sub> superconductors: processing, characterization and enhancement of critical fieldsBhatia, Mohit 21 September 2007 (has links)
No description available.
|
1057 |
Periodic Forcing of a System near a Hopf Bifurcation PointZhang, Yanyan 17 December 2010 (has links)
No description available.
|
1058 |
Utveckling av en generell metod för läckageövervakning vid fyllningsdammarGasim, Alia January 2020 (has links)
Fyllningsdammar har alltid ett naturligt läckage då jordmaterialet som används har en viss permeabilitet. Detta acceptabla naturliga läckage är viktigt att övervaka för att kontrollera att läckageflödet håller sig inom förväntade värden. Om läckaget blir för stort, kan det leda till felmoder som i sin tur leder till dammbrott. Damminstrumentering som möjliggör övervakning av läckage i fyllningsdammar är ett krav enligt RIDAS. På nedströmssidan av fyllningsdammar finns det dränagerör som samlar upp och leder läckagevatten till platser där läckaget mäts med något slags instrument. Detta mätinstrument mäter inte endast läckaget genom fyllningsdammar, utan påverkas även av yttre faktorer såsom nederbörd och evapotranspiration. Detta examensarbete syftar därför att utveckla en generell metod för läckageövervakning vid fyllningsdammar, för att erhålla det normala läckaget. Hur det normala läckaget kan erhållas allmängiltigt för fyllningsdammar har presenterats. Det normala läckaget genom dammkroppen kan antingen erhållas med hjälp av fysikalisk läckageberäkning (qD1,Fysikalisk) eller från läckagemätning (qD1,Läckagemätning). Fysikalisk läckageberäkning bygger på en genomströmningsmodell baserat på fysikaliska samband. Läckage från läckagemätning baseras på en vattenbalansekvation där läckageflödet är en term av flera, som uppmätt läckage nedströms dammen, nederbörd och avdunstning. En fallstudie har genomförts för en av Vattenfalls dammanläggningar för att testa den metodik som framtagits för erhållande av det normala läckaget. De fysikaliska läckageberäkningarna har modellerats fram med hjälp av COMSOL Multiphysics och läckaget från läckagemätningarna har beräknats fram med hjälp av vattenbalansekvationen och indata på hydrologi. Resultatet visar att det är viktigt att ta hänsyn till de yttre faktorerna från vattenbalansekvationen eftersom dessa kan ha en betydande påverkan på det läckageflöde som faktiskt mäts. Vidare bedöms det betydande att modellera läckage baserat på en fysikalisk baserad strömningsmodell eftersom detta värde sällan finns idag. Då kan en jämförelse av läckage från läckagemätningar jämföras med det fysikaliska läckaget. Det bedöms att beräkning av läckage från läckagemätningar med hjälp av vattenbalansekvationen är en bra metod för att beräkna läckaget genom dammar. Dock behöver den studerade dammanläggningen en djupare analys för att senare kunna tillsätta gränsvärden. Detta genom att även undersöka läckage under dammkroppen och magasinsförändringar vid beräkning av läckage från läckagemätningar. Det fysikaliska läckaget genom att modellera genomströmningen för hela geometrin och genom att utföra en tidsberoende modellering. / Embankment dams are not completely impervious as its core materials has a certain permeability. This seepage is important to monitor to follow-up to ascertain that it stays as expected. If the seepage increase above design, failure modes could occur and ultimately a dam failure. The Swedish dam safety guideline RIDAS deals with this safety aspect by requirements on instrumentation to measure seepage. Downstream embankment dams, drainage leads seepage water to an outflow point where seepage can be measured. However, at these points the measured flow also is impacted by external factors such as precipitation and evapotranspiration. The aim of this report is to propose a method where the measured flow by post-processing can exclude the impact of these external factors. The normal seepage through a dam can either be obtained by modelling (where the physical seepage has been obtained based on physical relationships) or by a water balance equation (where the seepage from measurement downstream a dam is a part of the water balance equation, including the impact by precipitation and evapotranspiration. A case study has been carried out on a dam operated by Vattenfall, as a means to assess the proposed methodology. The seepage has been modelled using the COMSOL Multiphysics software, and the seepage from measurements has been calculated by the water balance equation. The results show that it is important to take into account external factors as it clearly affects the measured seepage flow. Furthermore, it is of great importance to calculate the theoretical design seepage, which is a threshold value level that is rarely modelled today. If both the seepage from measurements and theoretical seepage is obtained, a comparison of these can be made. The seepage from measurements (with the help of the water balance equation) is a good method to obtain embankment dam seepages. However, the results from the case study implies that further work is needed to be able to set relevant limit values.
|
1059 |
Virtual Power Plant Optimization Utilizing the FCR-N Market : A revenue maximization modelling study based on building components and a Battery Energy Storage System. Based on values from Sweden's first virtual power plant, Väla.Edwall, Bill January 2020 (has links)
Renewable energy resources are projected to claim a larger part of the Swedish power mix in coming years. This could potentially increase frequency fluctuations in the power grid due to the intermittency of renewable power generating resources. These fluctuations can in turn cause issues in the power grid if left unchecked. In order to resolve these issues, countermeasures are employed. One such countermeasure is for private actors to regulate power; in exchange they are financially compensated through reserve markets. The reserve market studied in this thesis is called Frequency Containment Reserve – Normal (FCR-N). Currently hydroelectric power provides almost all regulated power within this market. As the need for power regulation is expected to increase in the coming years, there exists a need to study other technologies capable of power regulation. This thesis focuses on one such technology called, virtual power plants. While virtual power plants are operating in other parts of the world, there were no virtual power plants operating in Sweden. As a result, the nature of an optimized virtual power plant and the economic benefits of optimization had not been previously investigated. To answer such questions, this thesis modelled and optimized the revenue of a virtual power plant. The examined virtual power plant consisted of cooling chillers, lighting, ventilation fans and a battery energy storage system. Where varying their total power demand allowed for them to provide power regulation. With the virtual power plant market in Sweden being in its infancy, this thesis serves as a first look into how an optimized virtual power plant using these components could function. To put the economic results of the optimization into context, a comparative model was constructed. The comparative model was based on a semi-static linear model. This is what the thesis’s industry partner Siemens currently uses. For the simulated scenarios, the optimized model generated at least 85% higher net revenues than the semi-static linear model. The increase in revenue holds potential to increase the uptake of virtual power plants on the Swedish market, thus increasing stability in the power grid and easing the transition to renewable energy. / Då förnyelsebara energiresurser antas omfatta en större roll av den svenska elproduktionen inom kommande år, så kan detta leda till att frekvensfluktueringar i elnätet ökar. Detta sker på grund av att den oregelbundna elproduktionen från förnyelsebara energiresurser inte matchas med konsumtion. Om dessa fluktueringar inte hanteras kan det i sin tur leda till skadliga störningar inom elnätet. För att motverka detta och således stabilisera elnätet används diverse lösningar. Ett sätt att åstadkomma ökad stabilisering i elnätet är att låta privata aktörer kraftreglera. De privata aktörerna som står för kraftregleringen gör detta i utbyte mot ekonomisk kompensation, genom att delta i reservmarknader. Den reservmarknad som studerades inom detta examensarbete kallas Frequency Containment Reserve – Normal (FCR-N). I nuläget står vattenkraft för nästan all reglerad kraft inom den här marknaden. Men då behovet av kraftreglering antas öka inom kommande år så behövs nya teknologier studeras som kan bistå med kraftregleringen. Den studerade teknologin inom detta examensarbete var ett virtuellt kraftverk. Då inga virtuella kraftverk var i bruk i Sverige då denna uppsats skrevs fanns det osäkerheter kring hur man optimalt styr ett virtuellt kraftverk och de ekonomiska fördelarna som detta skulle kunna leda till. Detta examensarbete modellerade och optimerade ett virtuellt kraftverk ur ett vinstperspektiv. Det virtuella kraftverket var uppbyggt utav kylmaskiner, ljus, ventilationsfläktar och ett batterisystem. Deras kraftkonsumtion styrdes på ett sådant sätt som lätt de bidra till kraftreglering på reservmarknaden. För att kunna analysera de ekonomiska resultaten från det optimerade virtuella kraftverket, så byggdes en jämförelsemodell. Denna jämförelsemodell är baserad på en semistatisk linjär modell, vilket är det som examensarbetets industripartner Siemens använder. Den ekonomiska jämförelsens resultat påvisade att inkomsten från den optimerade modellen var minst 85% högre än den semistatiskt linjära modellen, inom de studerade scenarierna. Denna inkomstökning skulle potentiellt kunna öka användningen av virtuella kraftverk på den svenska reservmarknaden vilket i sin tur skulle medföra högre stabilitet på elnätet. Genom att öka stabiliteten på elnätet kan således förnyelsebara energiresurser i sin tur lättare implementeras.
|
1060 |
THE IDENTIFICATION AND DIFFERENTIATION BETWEEN NORMAL AND SECONDARY COLORECTAL CANCER IN HUMAN LIVER TISSUE USING X-RAY INTERACTION TECHNIQUESDarvish, Molla Sahar 10 1900 (has links)
<p>As secondary colorectal liver cancer is the most widespread malignancy in patients with colorectal cancer, the main aim of this study is to identify and differentiate between benign and malignant secondary colorectal liver cancer tissue. Low energy X-ray interaction techniques were used. XRF and coherent scattering data were collected for all 24 normal and 24 tumour matched pair tissues. Measurements of these parameters were made using a laboratory experimental set-up comprising a Mo X-ray tube, Si Drift detector and Scintillation (NaI) detector.</p> <p>Twelve elements of interest were statistically explored for normal and tumour samples. Comparing normal and tumour tissues, statistically significant differences have been determined for K, Ca, Cr, Fe, Cu, Zn, Br and Rb. However, for P, S, As and Se, no statistically significant differences have been found.</p> <p>Coherent scatter profiles were collected and fitted for all the samples and three peaks were observed at momentum transfer values: adipose peak: 1.1 nm<sup>-1</sup>, fibrous peak: 1.6 nm<sup>-1</sup> and water content peak: 2.2 nm<sup>-1</sup>. The Amplitude, FWHM and area under these peaks were statistically analysed. These parameters were found to be significantly higher in secondary colorectal liver tumour compared to surrounding normal liver tissue for both fibrous and water content peaks. However, no significant differences were found for adipose peak parameters.</p> <p>Multivariate analysis was performed using the XRF, coherent scatter and elemental ratios data separately and the accuracy of classification results of 20 unknown samples was found. However when all the variables were combined together, the classification models were improved. This study has shown that the XRF and coherent scatter data of normal and secondary colorectal liver cancer are statistically different and the combination of these variables in multivariate analysis has the potential to be used as a method of distinguishing normal liver tissue from the malignant tumour tissue.</p> / Master of Science (MSc)
|
Page generated in 0.0534 seconds