101

On-line optimisation of backflush duration in a membrane bioreactor using hollow fibre ultrafiltration membranes

Zahir, Nayar January 2000 (has links)
No description available.
102

Mechanisms of membrane fouling by macromolecules at multiple scales during ultrafiltration

Shi, Xiafu January 2014 (has links)
The thesis aims to gain a better understanding on the mechanisms of the complicated macromolecular fouling in ultrafiltration (UF). The work is divided into three main parts. Firstly, comprehensive literature reviews on both membrane fouling and cleaning were carried out for a better overview on this problem. The findings such as the identification of the main foulants and the current knowledge on fundamental fouling mechanisms, directly contributed to further parts of the thesis. Secondly, a multiscale approach was developed to form generalised framework for modelling complex fouling scenarios. Two complex fouling models combining multi- ple fouling mechanisms were derived accordingly. The models were then applied to the filtration data collected from UF experiments (constant-pressure and dead-end) on three individual macromolecular solutes, i.e., dextran blue (DB), polyethylene oxide (PEO), and humic acid (HA), respectively. During the experiments, the effect of macromolecular concentration and transmembrane pressure was investigated. Using the appropriate combined model, the overall and initial fouling behaviours and the predominant fouling mechanisms at different stages of filtration were identified. The fouling parameters in the combined models were determined and found to be consistent with the existing theories. The switch points between the dominant fouling mechanisms were assessed using two methods (integral and differential), respectively. Comparing all the information together gave a comprehensive understanding of the physics involved in the macromolecular fouling. Finally, the effect of the deformability of a macromolecule on membrane fouling was studied. The sieving results from the experiments indicated a flux-dependent permeation during UF of the DB solution, hypothetically due to the elongational deformation of the large DB molecule (a linear polymer at 2000 kDa MWCO) under high velocity gradient at the pore entrance, allowing the molecule to adapt a smaller transversal size to enter pores at nominally 100 kDa cutoff. This not only increased the chances of permeation but also the probability of severe irreversible fouling. Subsequently, a mesoscopic model using dissipative particle dynamics (DPD) was developed to investigate the blocking event at the pore entrance in the presence of a deformable linear macromolecule. The simulation results shed lights on the threshold permeating flux at which the molecular chains start to deform.
103

Study of high protein dairy powder (MPC80) susceptibility to fouling and efficacy of micro-nano-bubble aqueous ozone in removal of Bacillus spp. biofilms on stainless steel surfaces

Gandhi, Gagan January 1900 (has links)
Master of Science / Food Science Institute / Jayendra K. Amamcharla / Fouling and biofilm formation on stainless-steel (SS) surfaces can be sources for cross-contamination and pose a great threat to the public health and food quality. The dairy industry needs an intervention strategy focusing on technologies discouraging the biofilm attachment and developing a sustainable eco-friendly approach for biofilm removal from the dairy processing surfaces. Since fouling encourages the attachment of bacteria to the SS surfaces, it becomes important to study the ways of reducing the fouling. The bacterial attachment to the fouled SS surfaces can be prevented by modifying the SS surface properties by chemical (using coatings) or mechanical methods. On the other hand, the degree of fouling can also be reduced by using good quality raw materials. The objective-1 of the study was focused on understanding the relationship between effect of milk protein concentrate (MPC80) solubility characteristics and fouling on SS surfaces during thermal processing. The powders were stored at different temperatures (25 ºC and 40 ºC) for 2 weeks to generate powders with different dissolution characteristics. Fouling characteristics of reconstituted MPC80 powder were studied using a custom-built benchtop plate heat exchanger. Exposing the MPC80 powder to a higher temperature during storage (40 ºC) significantly decreased the solubility and increased the amount of foulant on SS coupons (P < 0.05). Microscopic investigations (scanning electron microscopy and laser scanning confocal microscopy) of resulting fouled layers revealed heterogeneous fouling layers of varying tomographies, consisting of lipids, proteins, and calcium. In the second study, the efficacy of Micro- and Nano-bubble aqueous ozone (MNAO) as a disinfectant was studied in removal of Bacillus cereus and Bacillus licheniformis biofilm from the SS surface. For the Bacillus cereus biofilm removal, a log reduction of only 0.68 cfu/cm2 was observed after the de-ionized water wash. Whereas both MNAO and cleaning-in-place (CIP) treatments significantly reduced the bacterial counts by 2.43 and 2.88 log10 cfu/cm2, respectively. On the other hand, for the Bacillus licheniformis biofilm removal from SS surfaces, a significant log reduction observed was 1.45, 3.03, 2.92 log10 cfu/cm2, respectively after de-ionzed water, MNAO, and CIP treatments. Thus, it was observed that MNAO has great potential for removal of Bacillus cereus and Bacillus licheniformis biofilms from the SS surface, and can be used in the dairy industry as an effective sanitizer/disinfectant
104

Investigation of effect of dynamic operational conditions on membrane fouling in a membrane enhanced biological phosphorus removal process

Abdullah, Syed Zaki 05 1900 (has links)
The membrane bioreactor (MBR) is becoming increasingly popular for wastewater treatment, mainly due to its capability of producing high quality effluent with a relatively small footprint. However, high plant maintenance and operating costs due to membrane fouling limit the wide spread application of MBRs. Membrane fouling generally depends on the interactions between the membrane and, the activated sludge mixed liquor, which in turn, are affected by the chosen operating conditions. The present research study aimed to explore the process performance and membrane fouling in the membrane enhanced biological phosphorus removal (MEBPR) process under different operating conditions by, (1) comparing two MEBPRs operated in parallel, one with constant inflow and another with a variable inflow, and by, (2) operating the MEBPRs with different solids retention times (SRT). On-line filtration experiments were conducted simultaneously in both MEBPR systems by using test membrane modules. From the transmembrane pressure (TMP) data of the test membrane modules, it was revealed that fouling propensities of the MEBPR mixed liquors were similar in both parallel reactors under the operating conditions applied, although the fouling propensity of the aerobic mixed liquors of both reactors increased when the SRT of the reactors was reduced. Routinely monitored reactor performance data suggest that an MEBPR process with a varying inflow (dynamic operating condition) performs similarly to an MEBPR process with steady operating conditions at SRTs of 10 days and 20 days. Mixed liquor characterization tests were conducted, including critical flux, capillary suction time (CST), time to filter (TTF) and, bound and soluble extracellular polymeric substances (EPS) were quantified, to evaluate their role on membrane fouling. The tests results suggest that the inflow variation in an MEBPR process did not make a significant difference in any of the measured parameters. With decreased SRT, an increase in the concentrations of EPS was observed, especially the bound protein, and the bound and soluble humic-like substances. This suggests that these components of activated sludge mixed liquors may be related to membrane fouling. No clear relationship was observed between membrane fouling and other measured parameters, including critical flux, normalized CST and normalized TTF. / Applied Science, Faculty of / Civil Engineering, Department of / Graduate
105

Hollow Fiber Ultrafiltration of Ottawa River Water: Impact of Different Pre-treatment Schemes

Walker, Steven January 2014 (has links)
To minimize membrane fouling many water treatment plants pre-treat water prior to microfiltration (MF) or ultrafiltration (UF). Coagulation/flocculation/sedimentation is a common form of pre-treatment, but little research has been conducted on floatation as a part of the pre-treatment. The objective of this thesis is to compare pre-treatment with floatation and with sedimentation for Ottawa River water, a typical Northern Canadian water with a high natural organic matter (NOM) content and a large hydrophobic (HPO) NOM fraction. Fouling tests consisted of multiple filtration/backwashing cycles performed by an automated bench-scale UF hollow fiber membrane system. Test were conducted with Ottawa River water (ORW) and ORW subjected to three different types of pre-treatment conducted at closely-located full-scale water treatment plants, including one using floatation. Both Alum pre-treatments resulted in decreases in NOM (63% and 68% TOC) and HPO NOM (56% and 68%TOC) which helped to reduce fouling. However, the remaining NOM and HPO NOM still caused significant hydraulically and chemical irreversible fouling. The water pre-treated with floatation produced the least severe hydraulically irreversible fouling for all experiments while Raw ORW produced the highest. During the early stages of membrane filtration (~10 hours), the TMP sharply increases which may imply that adsorption is dominant. Statistical analysis during the initial stages of filtration showed that the HPO fraction of NOM was linked to hydraulically irreversible fouling, which may be attributed to adsorption. Raw ORW also had the highest hydraulically reversible fouling while all pre-treatments were able to reduce this type of fouling. Statistical analysis suggested that the transphilic (TPI) fraction of NOM and particulate organic carbon (POC) were responsible for hydraulically reversible fouling during subcritical flux experiments, which may be attributed to cake formation on the membrane surface. It was found that for all waters and experiments, hydraulically irreversible fouling was greater than hydraulically reversible fouling. This may be because of the high HPO concentrations in the ORW. Hydraulically reversible fouling and backwash efficiencies were found to fluctuate with time. It is hypothesised that the cake formation adheres to the membrane surface and is not fully removed until enough backwash pressure has developed. Further investigation into alternative cleaning procedures is required as the NaOH cleaning was not very effective for some of the pre-treated waters.
106

AOM Characterization and Removal Efficiency Using Various SWRO Pretreatment Techniques

Namazi, Mohammed 12 1900 (has links)
This study investigates the operation of dual media filter DMF during ambient and simulated algal bloom conditions, and the role of coagulation and dissolved air flotation (DAF) in mitigating the adverse effects of algal blooms on DMF performance. The study also highlights which AOM concentration as a function of biopolymer is critical to organic fouling in DMF pretreatment for Red Sea water desalination with RO. On the other hand, the present study has carried out another experiment on AOM fouling in comparison with bacterial organic matter (BOM) and humic organic matter (HOM) using two different pore sizes of UF ceramic membranes, 5 and 50 kDa. The main aim of this comparison is to examine fouling behavior and mechanism and removal efficiency. The study revealed that AOM can induce organic fouling in DMF during simulated algal bloom conditions at biopolymer concentrations as low as 0.2 mg C/L. DMF performance was strongly affected by AOM concentration as observed by flow rate decline through time. Liquid chromatography – organic carbon detection (LC-OCD) analysis showed higher removal rates of biopolymers than lower molecular weight fractions (i.e., humic substances, building blocks and low molecular weight neutrals) for all pretreatment scenarios. The study also indicated that while DMF performance was enhanced with coagulation and sedimentation, the most significant improvement in performance was observed for DMF operation preceded by coagulation and DAF. Hydraulic performance of DMF correlated well with biopolymers removal, with removal rates of 72%, 53% and 39%, for coagulation/DAF, coagulation/sedimentation, and no coagulation, respectively. For UF ceramic membranes, results showed that more TEP/organics were removed by the 5 kDa membranes compared to the 50 kDa membrane, which is accounted for lower MWCO. The UF 5 kDa membrane also showed low fouling formation than 50 kDa membrane for all of three types of organic matter tested. Analysis of the fouled membranes by SEM images showed that fouling was dominated by cake layer formation for the 5 kDa membrane while pore blockage followed by cake layer formation is apparent for the 50 kDa membrane.
107

Investigation of the Effect of Operational Parameters on the Fouling Development and Control in an Algal Membrane Photobioreactor for the Treatment of Simulated Secondary Wastewater

Lamprea Cala, Andres 07 1900 (has links)
The release of water effluents rich in nutrients such as nitrogen and phosphorus without adequate treatment represents environmental and human health concerns. Growing concerns about these impacts have resulted in increasingly stringent water quality regulations that encouraged the adoption of advanced treatment processes. Microalgae-based advanced wastewater treatment has gained momentum owing to its well-known advantages for advanced wastewater treatment, including the recovering of nutrients for the production of fertilizers, biofuels and fine chemical from microalgal biomass. Nevertheless, the progressive membrane fouling and permeate flux declining hamper the large-scale commercialization of membrane photobioreactors (MPBRs) in the wastewater sector. In order to get a further understanding of the fouling mechanisms and antifouling control strategies, this study investigated the effect of the hydraulic retention time on the fouling development, and the effect of different physical fouling control strategies in the fouling mitigation. A synthetic secondary effluent was continuously fed to three MPBRs operated at different HRTs (12, 24 and 36 hours). Different fouling behaviors were found as the HRT changed, which was confirmed by continuously monitoring the transmembrane pressure (TMP) and by measurements in the biomass and its algal organic matter (AOM) properties. Lowering the HRT resulted in higher fouling rates due to changes in the biomass and AOM properties. Higher HRTs led to lower fouling rates and to a lower organic rejection across the membrane. The retention of small-MW organics in SMPBR12h was found to exacerbate the fouling resistance, whereas the accumulation of large-MW biopolymers enhanced the rejection of organics, despite of not imparting significant resistance in SMPBR24h. In order to assess the impact of different physical fouling control strategies, namely relaxation, backwash and air scouring, OCT in-situ monitoring was employed in MPBR12h to provide real-time information of the fouling layer properties (thickness and relative roughness) and its interaction with the membrane surface. Different fouling mechanisms were observed under different fouling control strategies. MPBRRLX and MPBRBW presented similar fouling rates despite of the lower permeate productivities of the latter. The lowest fouling rates were observed in MPBRSC, where stronger interactions between the membrane and small-MW organics and particles was observed.
108

Surface Property Modification of Coatings via Self-Stratification

Pieper, Robert Joseph January 2010 (has links)
Biological fouling occurs everywhere in the marine environment and is a significant problem for marine vessels. Anti-fouling coatings have been used effectively to prevent fouling; however, these coatings harm non-targeted sea-life. Fouling-release coatings (FRC) appear to be an alternative way to combat fouling. FRC do not necessarily prevent the settlement of marine organisms but rather allow their easy removal with application of shear to the coatings surface. These coatings must be non-toxic, non-leaching, have low surface energy, low modulus, and durability to provide easy removal of marine organisms. Here the goal is to develop FRC based on thermosetting siloxane-polyurethane, amphiphilic polyurethane, and zwitterionic/amphiphilic polyurethane systems. A combinatorial high-throughput approach has been taken in order to explore the variables that may affect the performance of the final coatings. Libraries of acrylic polyols were synthesized using combinatorial high-throughput techniques by either batch or semi-batch processes. The design of the experiments for the batch and semi-batch processes were done combinatorially to explore a range of compositions and various reaction process variables that cannot be accomplished or are not suitable for single reaction experiments. Characterization of Rapid-GPC, high-throughput DSC, and gravimetrically calculated percent solids verified the effects of different reaction conditions on the MW, glass transition temperatures, and percent conversion of the different compositions of acrylic polyols. Coatings were characterized for their surface energy, pseudobarnacle pull-off adhesion, and were subjected to bioassays including marine bacteria, algae, and barnacles. From the performance properties results the acrylic polyol containing 20% hydroxyethyl acrylate and 80% butyl acrylate was selected for further siloxane-polyurethane formulations and were subjected to the same physical, mechanical, and performance testing. Amiphiphilic copolymers based on PDMS molecular weight and the addition of PEG based polymer blocks on the properties of acrylic-polyurethane coatings were explored. The key properties screened were surface energy, determined by contact angle measurements using water and methylene iodide, dynamic water contact angle, and pseudobarnacle adhesion properties. The data from all of the biological assays indicates that the novel coatings were able to resist fouling and have low fouling adhesion for the broad variety of fouling organisms tested.
109

Carbon dioxide nucleation as a novel cleaning method for ultrafiltration membranes

Al Ghamdi, Mohanned 08 December 2016 (has links)
The use of low-pressure membranes, mainly ultrafiltration (UF), has emerged in the last decade and began to show acceptance as a novel pretreatment process for seawater reverse osmosis (SWRO) desalination. This is mainly due to the superior water quality provided by these membranes, in addition to reduction in chemicals consumption compared to conventional methods. However, membrane fouling remains the main drawback of this technology. Therefore, frequent cleaning of these membranes is required to maintain water flux and its quality. Usually, after a series of backwash using UF permeate chemical cleaning is required under some conditions to fully recover the operating flux. Frequent chemical cleaning will probably decrease the life time of the membrane, increase costs, and will have some effects on the environment. The new cleaning method proposed in this study consists of using a solution saturated with carbon dioxide (CO2) to clean UF membranes. Under the drop in pressure, this solution will become in a supersaturated state and bubbles will start to nucleate on the surface of the membrane and its pores from this solution resulting in the removal of the fouling material deposited on the membrane. Different compositions of fouling solutions including the use of organic compounds such as sodium alginate and colloidal 5 silica with different concentrations were studied using synthetic seawater with different concentrations. This cleaning method was then compared to the backwash using Milli-Q water and showed an improved performance compared to it. An operational modification to this cleaning technique was then investigated which includs a series of sudden pressure drop during the backwash process. This enhanced technique showed an even better performance in cleaning the membrane, especially at severe fouling conditions. In most cases, the membrane permeability was fully recovered even at harsh conditions where conventional backwash failed to maintain a stable operation. Therefore, the new cleaning method might provide an efficient and environmentally friendly alternative cleaning technique to low-pressure membranes technology in the future.
110

The development of a test rig to determine fouling factors of feedwater heaters

Hallatt, Nicolaas 04 May 2020 (has links)
Feed water heaters are large shell and tube heat exchangers. They from part of the Rankine cycle used in coal fired power plants with the main purpose being the improvement of the overall cycle efficiency. Like most heat exchangers, feed water heaters suffer from fouling. Fouling is defined as “any undesirable deposit on heat exchanger surfaces that increases resistance to heat transmission”. In the design of heat exchangers, fouling is accommodated by adding additional surface area to the heat exchanger. The amount of additional area is determined by the use of fouling factors. Although this is the only wide-spread method accepted in industry, the fouling factors in use are outdated, generally considered conservative and lead to oversized heat exchangers. The purpose of this study was to design and build a test rig that can accurately measure fouling factors of feed water heater tubes that has been in service for a full life cycle. A comprehensive literature study was performed to decide on the most effective test method, as well as the required instrument type and accuracy. The best method was found to be where the overall heat transfer coefficient for a fouled tube, outside cleaned tube (half clean) and clean tube was measured. The measured values are then converted to the internal, external and overall fouling factors. Validation test were done on the test rig. These included energy balance tests, theoretical comparison tests and repeatability tests. The results of all tests were acceptable and within measurement uncertainty limits. Five sample test tubes, obtained from a 30 year old LP heater at an Eskom power station, were tested. The results indicated that the average measured fouling factors were less than 20% of the commonly used HEI fouling factors. This is significantly lower and confirms that the fouling factors in use for this specific case are conservative. The test rig proved to be accurate and effective in measuring the fouling factors. Although the tests shows promising results, the small amount of tubes tested from only one heat exchanger are not sufficient to make meaningful conclusions. The test rig is now ready for a future study where a large sample of tubes can be tested.