Volume calculation of the thyroid gland from SPECT images based on Monte Carlo simulationsPalmqvist, Niklas January 2018 (has links)
In this study the volume determination which is a part of the doseplanning for patients with thyrotoxicosis was investigated. The aim was to find an accurate method to determine the active volume with single photon emission tomography (SPECT) which in several studies have shown better results than with the currently used method planar scintigraphy (PS). This was implemented on the Xeleris 3.1 by General Electric (GE) at the University Hospital of Umeå (NUS). The examination time with SPECT is required not to be significantly longer than the examination time with PS. Despite the relatively short examination time, the accuracy of the volume determination should be more accurate. This was analyzed with a true value of the volume, conducted with Monte Carlo simulations of digital anthropomorphic phantoms. It is also important that the developed method is user friendly. The study included ten patients with thyrotoxicosis from which, relative activity uptakes were measured. These uptakes were specified in 22 digital XCAT phantoms which were random sampled with respect to phantom mass. The Monte Carlo program "simulating medical imaging nuclear detectors" (simind) was used to simulate the SPECT-system. The projection images were ordered subset expectation maximization (OSEM) reconstructed and Butterworth filtered. Unfiltered images were used to compare volume calculations with filtered ones. The volume of the thyroid was segmented using threshold values applied to all voxels in the image-sets and the optimization of the thresholds was conducted by numerical calculations. The results in this study shows that the best choice of intensity threshold value is 21.1(24)% of the maximum voxel value for all phantoms. The threshold is valid for OSEM iteration number five and unfiltered image-sets. Butterworth filtered images were less suitable to use than unfiltered images when the thyroid volume was calculated with data from SPECT-simulations of phantoms.
|
202 |
Tomografia por emissão de pósitrons com sistemas PET/SPECT: Um estudo da viabilidade de quantificação / Positron Emission Tomography PET / SPECT Systems Study Viability QuantificationLorena Pozzo 04 March 2005 (has links)
A Tomografia por Emissão de Pósitrons (PET - Positron Emission Tomography) é uma modalidade de imagens para o diagnóstico em Medicina Nuclear. São utilizados radiofármacos emissores de pósitrons que possibilitam obter imagens que representam o processo bioquímico dessas substâncias no órgão ou tecido de interesse in vivo. São detectados, em coincidência, os fótons provenientes da aniquilação pósitron/elétron, que ocorre dentro do corpo do paciente. Esta informação é posteriormente utilizada para a reconstrução do objeto em estudo. Atualmente, existem dois tipos de equipamentos capazes de realizar estudos tomográficos por emissão de pósitrons: o dedicado e a câmara PET/SPCET. Este trabalho abordou este último tipo, que permite também a realização de exames habituais de Medicina Nuclear, que usam emissores de fótons. Existem dificuldades inerentes ao método de aquisição destas imagens que afetam a quantificação de índices ou atividade. Elas estão relacionadas ao fato de a emissão de radiação obedecer a uma distribuição de Poisson, às interações físicas da radiação com o corpo do paciente e com o detector, ao ruído devido à natureza estatística destas interações e de todo o processo de detecção, assim como à metodologia de aquisição dos exames (preparo e posicionamento do paciente, taxa de contagens etc.). Correções são propostas na literatura que não são totalmente implementadas pelos fabricantes: de espalhamento, de atenuação, de eventos aleatórios, do tempo morto, de decaimento, da resolução espacial e de outras características do equipamento. O objetivo deste trabalho foi o de realizar um estudo dos métodos aplicados por dois fabricantes, assim como algumas influências das características técnicas das câmaras PET/SPECT na obtenção do índice de SUV (Standardized Uptake Value). Para isso, dados de simuladores físicos, dispostos em várias montagens, foram obtidos com uma câmara no modo 3D e outra no modo 20. Constatou-se também que a forma das fontes usadas para calibração influencia no resultado final e impõe novos desafios para a quantificação em uma situação clínica. Por fim, no momento da quantificação, a região de interesse deve ser escolhida de acordo com aquela usada para a determinação dos coeficientes de correção e calibração. Verificou-se que é viável realizar quantificações com câmaras PET/SPECT, inclusive o índice SUV. Para tanto, além das correções citadas anteriormente, é imprescindível ter o equipamento bem ajustado, assim como a obtenção de coeficientes para normalização da sensibilidade e correção do efeito de volume parcial. / Positron Emission Tomography (PET) is a Nuclear Medicine imaging modality for diagnostic purposes. Pharmaceuticals labeled with positron emitters are used and images which represent the in vivo biochemical process within tissues can be obtained. The positron/electron annihilation photons are detected in coincidence and this information is used for object reconstruction. Presently, there are two types of systems available for this imaging modality: the dedicated systems and those based on gamma camera technology. In this work, we utilized PET/SPECT systems, which also allows for the traditional Nuclear Medicine studies based on single photon emitters. There are inherent difficulties which affect quantification of activity and other indices. They are related to the Poisson nature of radioactivity, to radiation interactions with patient body and detector, noise due to statistical nature of these interactions and to all the detection processes, as well as the patient acquisition protocols. Corrections are described in the literature and not all of them are implemented by the manufacturers: scatter, attenuation, randoms, decay, dead time, spatial resolution, and others related to the properties of each equipment. The goal of this work was to assess these methods adopted by two manufacturers, as well as the influence of some technical characteristics of PET/SPECT systems on the estimation of SUV. Data from a set of phantoms were collected in 3D mode by one camera and 20, by the other. We concluded that quantification is viable in PET/SPECT systems, including the estimation of SUVs. This is only possible if, apart from the above mentioned corrections, the camera is well tuned and coefficients for sensitivity normalization and partial volume corrections are applied. We also verified that the shapes of the sources used for obtaining these factors play a role on the final results and should be dealt with carefully in clinical quantification. Finally, the choice of the region of interest is critical and it should be the same used to calculate the correction factors.
|
203 |
Simulação de um sistema PET pré-clínico com geometria de detecção variável / Simulation of a Preclinical PET System with Variable Scanner GeometryAndré Augusto de Farias Martins 30 July 2015 (has links)
A medicina nuclear é a área da ciência médica que usa radiofármacos, isto é um radionuclídeo ligado a uma molécula de interesse biomédico, para estudar o funcionamento do organismo. Com isso, essa ciência pode realizar diagnósticos de patologias ou tratamento oncológico. Os estudos pré-clínicos, estudo com pequenos animais, são requisitos de suma importância para o desenvolvimento dessa área. São esses estudos que permitem os testes de novos radiofármacos que possivelmente serão usados em humanos. Quando se trata de pequenos animais, os órgãos de estudo são muito pequenos, portanto é vital que o equipamento tenha uma ótima resolução espacial e boa sensibilidade. Na medicina nuclear, a tomografia por emissão de pósitron (Positron Emission Tomography, PET) tem as características necessárias para desenvolver esses estudos com pequenos animais. Os animais mais usados são ratos e camundongos, e como nem sempre esses animais representam modelo humano seria interessante ter um equipamento que também funcionasse em outros animais. Sendo esse tomógrafo caro, não é viável ter um equipamento para cada tipo de animal. O presente trabalho propõe justamente um único tomógrafo que possa ser usado em diferentes animais ou eventualmente em dois animais simultaneamente. Isso será alcançado variando o anel de detecção usado nesse tipo de tomógrafos. Isso é alcançado mais facilmente em geometrias retangulares, pois com apenas 4 hastes se consegue variar a distância máxima entre os detectores preservando a forma da geometria. O custo envolvido na construção física desse tomógrafo é elevado, consequentemente é interessante ter um teste preliminar que forneça dados que possam sustentar essa ideia. A melhor alternativa para esse teste é o uso de simulação computacional. GATE (Geant4 Application for Tomographic Emission) foi o programa escolhido para essa simulação, porque já é um software validado, isto quer dizer que é compatível com experimentos reais. Assim sendo, quatro simulações foram montadas, duas para geometrias circulares com diâmetros diferentes, e analogamente, duas quadradas. Para verificar qual das geometrias tem melhor performance, foram usados os métodos sugeridos pela norma NEMA NU 4-2008. Efetuados esses testes, pode-se observar que as geometrias quadradas tem resolução semelhante às circulares. A sensibilidade e a relação sinal-ruído são maiores nas geometrias quadradas. Portanto, conclui-se que no geral, as geometrias retangulares simuladas são melhores que as circulares. Esse resultado é motivador para dar início à construção física do tomógrafo, pois o mesmo permite desenvolver novos produtos de modo mais eficiente e com menos custo / Nuclear medicine is an area of medical science that uses radiopharmaceutical (a radionuclide bounded to a molecule of biomedical interest) to study human physiology by images. Thus, this science can perform diagnostics of diseases and eventually, in specific cases, cancer treatment. Before using a new radiopharmaceutical in humans it is necessary to test it in small animals. The organs in these animals are very small, consequently it is vital that the equipment has a great spatial resolution and high sensitivity. In nuclear medicine Positron Emission Tomography (PET) has this requirement. The most animal used to develop this kind of studies are rats and mice. However, they are not always representing human animal model, so equipment that works to other animals also it would be interesting. But it is not feasible to have equipment for each animal, because it will be very expensive. Therefore, the aim of this work is test one scanner that can be used in different animals or possibly in two animals at the same time. This will be achieved by varying the detection ring used in this type of scanners (PET). To do it, it is easier using rectangular geometries because moving only four stalks the distance between the detectors can be varied preserving the shape of the geometry. The cost involved in physical construction of this kind of tomograph is too high, therefore it is interesting have a preliminary test that provides some data which supports this idea. Computer simulation is a cheap alternative for this test and it is able to provide a reliable data. The software used to do the simulations was GATE (Geant4 Application for Tomographic Emission) because it has already validated, what means it is compatible with real experiments. Thus, four simulations were builded, two for circular geometries with different diameters and two for rectangular geometries. To check which kind of geometry has better performance, it used the methods suggested by NEMA NU 4-2008. At end of these tests, it is possible to observe that the spatial resolution in square geometries is similar to circular. The sensitivity and signal to noise ratio are higher in the square geometries. So, in general, it is concluded that the simulated rectangular geometries are better than circular certainly, this result can be motivating to begin physical construction of the scanner, as it allows developing new products more efficiently and with less cost.
|
204 |
Caracterização do gel polimérico MAGIC-f para aplicação em medicina nuclear utilizando imagens de ressonância magnética / MAGIC-f Gel Polimeric Caracterization for Nuclear Medicine Aplication using Magnética Ressonance ImageMarcelo Menna Barreto Schwarcke 18 October 2013 (has links)
Este trabalho visa aprimorar e tornar mais precisa a utilização do dosímetro gel polimérico MAGIC-f no estudo da distribuição de dose para fonte radioativas utilizadas na terapia e diagnóstico em medicina nuclear. Para isso foram avaliados os parâmetros de leitura do gel em equipamentos de ressonância magnética e sua resposta quando comparado a resultados obtidos através da utilização do código PENELOPE de simulação Monte Carlo. Dentre as incertezas observadas no processo global da utilização do gel MAGIC-f, sua manufatura foi a que demonstrou uma maior preocupação uma vez que erro na frações de componentes químicos adicionados ocasiona grande diferença na resposta do dosímetro. A aquisição da informação dosimétrica em um equipamento de imagem por ressonância magnética demonstrou que tempos ao eco mais curtos são mais eficientes na diferenciação do sinal gerado no processo de polimerização devido a utilização de fontes de medicina nuclear do que ajustes na resolução da imagem e que a homogeneidade de campo magnético pode ocasionar grande alteração nos valores obtidos. Experimentos realizados com o gel MAGIC-f, demonstraram um baixa dependência energética e um grande dependência com a taxa de dose, dois fatores importantes em medicina, mas resultados simulados e experimentais comparativos utilizando fontes de I-131, Tc-99m e F-18, demonstraram uma grande precisão nos resultados apresentados, tornando assim o gel MAGIC-f uma excelente ferramenta na verificação volumétrica da dose absorvida na terapia com fontes de medicina nuclear. / This work aims to improve and make more accurate use of the gel dosimeter MAGIC-f polymer in the study of dose distribution for radioactive source used in therapy and diagnosis in nuclear medicine. For this, MRI parameters reading of the gel were evaluated and its response when compared to results obtained using a Monte Carlo simulation PENELOPE code. Among the uncertainties observed in the overall use of MAGIC-f gel, its manufacturing demonstrated a greater concern since error in chemical fractions added causes big difference in the response of the dosimeter. The acquisition of dosimetric equipment information in a magnetic resonance imaging showed that the shorter eco times are more efficient in differentiating the signal generated in the polymerization process due to the use of sources of nuclear medicine than image resolution changes and the homogeneity of the magnetic field can cause large difference in the results. Experiments performed with the MAGIC-f gel, demonstrated a low energy dependence and a large dependence on the dose rate, two important factors in nuclear medicine, but comparative results with simulated and experimental processes using sources of I-131, Tc-99m and F-18 showed a great accuracy in results, thus making the MAGIC-f gel an excellent tool for volumetric verification of absorbed dose therapy with sources of nuclear medicine.
|
205 |
Medida absoluta da atividade de 14C pelos métodos CIEMAT/NIST, TDCR e em sistema de coincidência 4πβ-γ / Primary standardization of C-14 by means of CIEMAT/NIST, TDCR and 4πβ-γ methodsMaria Kuznetsova 28 September 2016 (has links)
Neste trabalho foi padronizada uma solução de 14C emissor beta puro com energia máxima de 156 keV, por meio de três diferentes métodos: CIEMAT/NIST e TDCR (triple-to-double coincidence ratio) em sistemas de cintilação líquida e pelo método do traçador, em sistema de coincidências 4πβ-γ. O sistema de cintilação líquida TRICARB, equipado com dois tubos fotomultiplicadores, foi usado para aplicação do método CIEMAT/NIST, usando um padrão de 3H emissor beta puro com energia máxima de 18,7 keV como traçador de eficiência. O sistema de cintilação líquida HIDEX 300SL, equipado com três tubos fotomultiplicadores, foi utilizado para as medidas pelo método TDCR. As amostras de 14C e 3H, medidas nos sistemas de cintilação foram preparadas usando-se três coquetéis cintiladores comerciais Ultima Gold, Optiphase Hisafe3 e InstaGel-Plus a fim de comparar seu desempenho nas medidas.Todas as amostras foram preparadas com 15 mL de coquetel cintilador, em frascos de vidro com baixa concentração de potássio. Alíquotas conhecidas de solução radioativa foram depositadas nos coquetéis cintiladores. Para a variação do parâmetro indicador de quenching, foram utilizados: um carregador de nitro metano e 1 mL de água destilada. Para a padronização pelo método do traçador no sistema de coincidências 4πβ-γ, foi utilizado 60Co como emissor beta gama. As medidas foram feitas no sistema de coincidências por software SCS, usando discriminação eletrônica para alterar a eficiência beta. O comportamento da curva de extrapolação foi predito por meio do código Esquema, que utiliza a técnica de Monte Carlo. Os resultados da atividade da solução de 14C obtida pelos três métodos utilizados mostraram uma boa concordância dentro da incerteza experimental. / In this work, the primary standardization of 14C solution, which emits beta particles of maximum energy 156 keV, was made by means of three different methods: CIEMAT/NIST and TDCR (triple-to-double coincidence ratio) methods in liquid scintillation systems and the tracing method, in the 4πβ-γ coincidence system. TRICARB LSC (Liquid Scintillator Counting) system, equipped with two photomultipliers tubes, was used for CIEMAT/NIST method, using a 3H standard that emits beta particles with maximum energy of 18.7 keV, as efficiency tracing. HIDEX 300SL LSC system, equipped with three photomultipliers tubes, was used for TDCR method. Samples of 14C and 3H, for the liquid scintillator system, were prepared using three commercial scintillation cocktails, UltimaGold, Optiphase Hisafe3 and InstaGel-Plus, in order to compare the performance in the measurements. All samples were prepared with 15 mL scintillators, in glass vials with low potassium concentration. Known aliquots of radioactive solution were dropped onto the cocktail scintillators. In order to obtain the quenching parameter curve, a nitro methane carrier solution and 1 mL of distilled water were used. For measurements in the 4πβ-γ system, 60Co was used as beta gamma emitter. SCS (software coincidence system) was applied and the beta efficiency was changed by using electronic discrimination. The behavior of the extrapolation curve was predicted with code ESQUEMA, using Monte Carlo technique. The 14C activity obtained by the three methods applied in this work was compared and the results showed to be in agreement, within the experimental uncertainty.
|
206 |
Estudo da função glomerular em Golden Retrievers normais, portadores e afetados pela distrofia muscular progressiva (GRMD) / Study of glomerular function in golden retrievers normals, carriers and affected by progressive muscular dystrophy (GRMD)André Gatti 18 September 2007 (has links)
As distrofias musculares em crianças e adolescentes acometem 1 em cada 3000 nascimentos. A distrofia de Duchenne é de origem genética e herança recessiva ligada ao cromossomo X, sendo determinada pela ausência da proteína distrofina, apresenta caráter invariavelmente progressivo, natureza mórbida e fim letal. Até o momento não se conhece tratamento efetivo, mesmo com todo o conhecimento que se tem da etiopatogenia. O objetivo deste estudo foi avaliar, no modelo animal, utilizando cães golden retrievers normais portadores e afetados pela distrofia muscular progressiva, a existência de alterações na função glomerular, através da comparação entre os clearances de creatinina, clearance do radionuclídeo EDTA-cromo e da concentração sérica de uréia e creatinina. Os animais foram divididos em 3 grupos de 9 animais sendo grupo 1 controle, grupo 2 portador e grupo 3 afetados. Todos os animais foram submetidos ao mesmos protocolos de exames. Não foram identificadas alterações significativas entre os grupos ou individualmente, sendo que todos os resultados encontraram-se dentro dos limites de normalidade. Sendo assim lesões renais primárias, obscuras aos testes convencionais, descartando-se uma correlação entre a distrofia muscular e lesão na musculatura dos vasos renais que pudessem levar a alterações da função do órgão. / The muscular dystrophys in children and teenagers is taken in 1 each 3000 births. The Duchenne`s dystrophy is from genetics origin and recessive heritage linked to X cromossome, and also determined by the lacre of dystrophyne protein; it shows progressive characteristics, morbid nature and a letal end. So far there is no known effective treatment, even with all the ethiopatogein knowledge. The goal of use of normal golden retrievers dogs, bling then carriers and affected by the progressive muscular dystrophy, the changing existence in the glomerular function through the comparison between the creatinine clearance, EDTA-crome clearance and seric urea and creatinine. Aiming the early diagnostic of the renal pathology. The animals were divided in 3 groups of 9 animals, bling group 1 control animals, group 2 carriers animals and group 3 affected animals. All of then were submitted to the some examinations protocols Their was no relevant identification between the groups or either individually, as all the results were within the expected and natural limits. Likewise, renal primary wounds are not clear in traditional tests made in dystrophyc animals, mainly caused by the muscular wounds in reanal vases harming this way the organ function.
|
207 |
Validação da técnica de subtração entre os SPECTs crítico e intercrítico e o corregistro com a ressonância magnética na localização da zona epileptogênica em pacientes com epilepsias intratáveis do lobo frontal / Validation of the subtraction of the ictal and interictal SPECTs aligned with magnetic resonance technique in the localization of the epileptogenic zone in patients with pharmacoresistant frontal lobe epilepsyRicardo Fernandes do Amaral 25 September 2012 (has links)
Pacientes com epilepsias farmacorresistentes estão cada vez mais se beneficiando do tratamento cirúrgico, dado o avanço nas técnicas de diagnóstico. Com a cirurgia, busca-se tornar o paciente livre de crises sem que para isso sejam provocados déficits neurológicos secundários. Para que isso seja alcançado é fundamental que a região cerebral epileptogênica seja delimitada com precisão. Os principais meios que o neurofisiologista dispõe para localizar a zona epileptogênica (ZE) na avaliação pré-cirurgica são a eletroencefalografia escapelar e a ressonância magnética (RM). Nos casos em que a RM não apresenta lesões ou os dados obtidos são conflitantes as técnicas de imagem funcional tais como a tomografia por emissão de fóton único (SPECT) e a tomografia por emissão de pósitron passam a ter um papel decisivo. O SPECT crítico apresenta uma imagem da perfusão sanguínea cerebral no momento da crise evidenciando, assim, as áreas cerebrais que estavam mais ativas. A técnica de subtração do SPECT intercrítico do crítico e o corregistro deste resultado coma RM do paciente (SISCOM) tem sido estudada como uma maneira de aumentar a sensibilidade e especificidade do SPECT crítico. Este trabalho buscou estudar e validar o papel dos SPECT crítico, intercrítico e SISCOM na localização da ZE. Todos os pacientes com suspeita de epilepsias refratária do lobo frontal baseada nos outros exames, operados no período de 2007 a 2011 e que realizaram um SPECT crítico e um intercrítico foram considerados nesse estudo. Para cada SPECT crítico foi realizado o SISCOM e o resultado comparado com o local da ressecção e o resultado cirúrgico sendo calculadas as métricas de desempenho diagnóstico de cada um dos métodos de neuroimagem funcional. No total foram operados 14 pacientes e 5 tiveram um bom resultado cirúrgico. O SPECT crítico apresentou 40% de sensibilidade e 88,9% de especificidade enquanto que o SPECT intercrítico apresentou 40% de sensibilidade e 66,7% de especificidade. O SISCOM foi o método com melhores parâmetros de desempenho apresentando uma sensibilidade de 60% e uma especificidade de 88,9%. Esses resultados coadunam com os dados encontrados na literatura em que o SISCOM é o estado da arte na interpretação do SPECT crítico e sugerem que o SISCOM tem potencial para ser utilizado na avaliação pré-cirurgica de pacientes com suspeita de epilepsias do lobo frontal. / The surgical treatment for patients with intractable epilepsies has become more efficient with the evolution of diagnosis techniques. The surgery aims at rendering the patient free of seizures, without postoperative neurological deficits. In order to accomplish this, it is of major importance to precisely delineate the epileptogenic zone (EZ). The main exams the neurologists use in order to find the EZ in the pre-surgical evaluation are the scalp electroencephalography and the magnetic resonance imaging (MRI). However, in cases where the MRI doesn\'t show any lesion or there are conflicting data, functional imaging such as Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography techniques play a crucial role. Ictal SPECT shows a snapshot of cerebral blood perfusion during the seizure, highlighting the most active areas during the ictus state and it has been shown this technique is useful in localizing the EZ in frontal lobe epilepsy cases. Sensitivity and specificity of ictal SPECT might be improved by a developed Computer Aided Diagnosis tool that subtracts the interictal SPECT image from the ictal one and coregisters the result with the MRI (SISCOM). In the present study, we aimed to evaluate the contribution of SISCOM to the pre-surgical evaluation in frontal lobe epilepsies. We considered for this study patients submitted to frontal lobe epilepsy surgery at our institution between 2007 and 2011 and with at least one ictal and one interictal SPECT. 14 patients were included and only 5 had a good outcome after the surgery. The ictal SPECT had a sensibility of 40% and specificity of 88,9% while the interictal SPECT showed a sensibility of 40% and a specificity of 66,7%. The sensitivity of the SISCOM tool was 60% and the specificity 88,9%.These results agree with the literature showing that SISCOM is the state-of-the-art in interpreting the ictal SPECT and has the potential to be used during presurgical evaluation of patients being considered for surgical treatment of frontal lobe epilepsy.
|
208 |
Caracterização dos padrões de drenagem linfática nas linfocintilografias de amostra de pacientes com melanoma / Characterization of the lymphatic drainage patterns in a sample of patients with melanomaTalitha Marmorato Granzotto 21 June 2011 (has links)
A linfocintilografia tem contribuído muito para a visualização da drenagem linfática e linfonodo sentinela (LNS) acometido e o estado patológico do LNS é considerado o fator prognóstico mais importante do melanoma. Os objetivos deste trabalho foram descrever os padrões de drenagem linfática em pacientes operados por melanoma, avaliar as características clínicas, demográficas e cirúrgicas destes pacientes, assim como a contribuição da Linfocintilografia na localização dos LNS com vistas à biópsia do mesmo. Foram avaliados 29 pacientes com melanoma operados, e a Linfocintilografia pré-operatória foi realizada após 60 minutos da injeção de Fitato marcado com Tecnécio 99m (99mTc), em 4 pontos cardeais a 1,0 cm da lesão. Encontramos maior acometimento por melanoma na população feminina e idosa, maioria em região de tronco posterior. A maioria (37,04%) drenou para 2 LNS/LNNS, 88,89% dos pacientes drenaram apenas para região ipsilateral à lesão, e 88,89% também drenaram apenas para um único território de drenagem. Encontramos padrões de drenagem linfática inesperados em melanoma localizados nas regiões de cabeça e pescoço, tronco anterior e tronco posterior. A técnica de linfocintilografia foi eficaz para evidenciar LNS/LNNS em 93,10% dos pacientes e dos 23 exames anatomopatológicos realizados, 6 (26,09%) apresentaram comprometimento metastático nos LNS. / Lymphoscintigraphy has contributed much to the visualization of lymphatic drainage and sentinel lymph node (SLN) and involved SLN pathological state is considered the most important prognostic factor of melanoma. Our objectives were to describe the lymphatic drainage patterns, to evaluate the clinical, demographic, and surgical data, as well as assessing the contribution of lymphoscintigraphy for SLN localization in a sample of patients operated for melanoma. We evaluated 29 patients operate with melanoma, and the Preoperative lymphoscintigraphy was performed after 60 minutes of injection of phytate labeled with Technetium 99m (99mTc) in 4 cardinal points to 1,0 cm of the lesion. We found greater involvement by melanoma in the elderly female population and, most located in the posterior trunk region. The majority (37.04%) drained for 2 SLN/ SLNN, 88.89% of the patients drained only to the ipsilateral region, and also 88,89% had lymphatic drainage to only a single drainage area. We found unexpected lymphatic drainage patterns in melanoma localized in head and neck, trunk, anterior and posterior trunk. The technique of lymphoscintigraphy was effective to show SLN/SLNN in 93.10% of patients, and from 23 pathological examinations performed, 6 (26.09%) exhibited metastatic involvement in the SLN.
|
209 |
Avaliação cintilográfica da regeneração óssea pós-cirurgia em coelhos / Scintigraphic evaluation of bone healing postoperative in rabbitsVinicius Pretti 22 November 2011 (has links)
A regeneração óssea é um importante processo fisiológico e bioquímico que acontece no tecido ósseo em resposta a diferentes tipos de agressões. Sejam elas o trauma, infecções, excessos de demanda de carga, lesões expansivas, malformações vasculares e alterações metabólicas sistêmicas, em quaisquer destas situações a remodelação e regeneração óssea assumem grande importância dada a relevância do esqueleto para a saúde humana. Neste sentido, faz-se importante desenvolver técnicas de pesquisa que permita-nos estudar in vivo as alterações metabólicas que acontecem no tecido ósseo em diferentes condições. Neste sentido, nosso objetivo foi o de utilizar a técnica de cintilografia óssea para avaliar a osteogênese secundaria à osteotomia em um modelo animal de coelho da raça New Zealand. Para tanto desenvolvemos um estudo longitudinal, prospectivo, caso-controle, no qual as variáveis cintilográficas foram mensuradas tanto na pata operada (pata anterior direita) quanto na pata controle (pata anterior esquerda). A amostra foi constituída por um grupo de 10 coelhos, inicialmente, os quais foram submetidos à osteotomia, seguindo-se um período de avaliação de 12 semanas pós-operatórias, divididas em três etapas de imageamento, com 4, 8 e 12 semanas. Como resultados observamos: (A) a pata operada apresentou uma radiação externa significativamente maior do que a controle, ao uso do colimador pinhole, denotando aumento da biodistribuição e tropismo do radiofármaco para a pata operada; (B) Dentre os 3 momentos avaliados, a osteogênese foi máxima em 4 semanas e apresentou declínio significativo nas 8a e 12a semanas, denotando regeneração e resolução da lesão cirúrgica; (C) A pata controle também foi influenciada pela inatividade imposta pela pata operada. Este fato ficou evidenciado notadamente pela também redução da osteogênese na pata anterior esquerda (controle). Concluimos que a técnica da cintilografia óssea foi sensível ao diferenciar semi-quantitativamente a osteogênese na pata operada, nos três marcos temporais avaliados no presente estudo. / Bone healing is an important physiological and biochemical process that occurs in bone tissue in response to different types of aggression. Whether the trauma, infections, excessive load demand, expansive lesions, vascular malformations and systemic metabolic changes in any of these situations remodeling and bone regeneration are very important given the relevance of the skeleton to human health. In this sense, it is important to develop research techniques that allow us to study in vivo the metabolic changes that occur in the bone tissue under different conditions. In this sense, our goal was to use the technique of bone scintigraphy to evaluate osteogenesis secondary to osteotomy in an animal model of New Zealand rabbits. For this purpose we developed a longitudinal, prospective, case-control study, in which the scintigraphic variables were measured both in the operated paw (right paw) and the control paw (left paw). The sample consisted of a group of 10 rabbits, initially, which underwent osteotomy, followed by an evaluation period of 12 weeks after surgery, divided into three stages of imaging, 4, 8 and 12 weeks. As results show: (A) the operated paw external radiation was significantly higher than the control, through pinhole collimator, showing increased radiotracer biodistribution and tropism for the operated paw, (B) Among the three time intervals, the osteogenesis was maximal at 4 weeks and showed significant decline in the 8th and 12th week, showing regeneration and resolution of the surgical lesion, (C) The control paw was also influenced by the inactivity imposed by the operated leg. This fact was also evidenced by markedly reduced osteogenesis in the left paw (control). We conclude that the technique of bone scintigraphy was sensitive to differentiate semiquantitatively osteogenesis in the operated leg in three timeframes in the current study.
|
210 |
APLICAÇÃO DE NANOPARTÍCULAS MAGNÉTICAS COMO MEIO DE CONTRASTE EM MEDICINA NUCLEAR E TOMOGRAFIA COMPUTADORIZADADias, Argleydson Leao 27 June 2018 (has links)
Made available in DSpace on 2018-06-27T18:56:11Z (GMT). No. of bitstreams: 2
Argleydson Leao Dias.pdf: 1337755 bytes, checksum: 52df54eb75dc5cec7ea7731423d3f307 (MD5)
Argleydson Leao Dias.pdf.jpg: 3247 bytes, checksum: 0ede54c629976ab39dc8cdfd8976d413 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The research developed in recent years shows the high potential of use of ferrofluids in
biomedical applications. One major area, in particular, is the use of biocompatible magnetic
nanoparticles as contrast agents in the cancer diagnostic and treatment. In this work we
evaluate the application of a fluid composed by magnetic nanoparticles of magnetite
stabilized by coating with dimercaptosuccinic acid (DMSA-FM) in an aqueous medium as a
contrast agent in nuclear medicine and computed tomography. The application in nuclear
medicine were carried out firstly performing radiochemical studies and second by performing
in vivo images of rats. The radiochemical studies shows that about 31% of technetium
remained in the free form, not bounded totaly to the FM - DMSA, and so comprometing the
location of the compound in several organs of the animal. The application of nanoparticles in
computed tomography was performed by using a head simulator object where syringes
containing different amounts of FM-DMSA and iodine, diluted in water were attached in
order to compare the contrast produced in the image by these two compounds. The results
showed that the attenuation by the FM-DMSA is approximately five times lower than the
values produced by the iodine. Although the attenuation produced by the compound FMDMSA
is less than that produced by iodine, the compound shows favorable properties for
applications as a contrast agent in computed tomography, since its effective atomic number is
much larger than those of soft tissues and the HU values measured at the images are in the
range of those produced by bone tissues. / As pesquisas desenvolvidas nos últimos anos evidenciam o alto potencial de aplicação
de ferrofluidos em diversas áreas biomédicas. Uma das áreas de maior interesse, em
particular, é o uso de nanoparticulas magnéticas biocompatíveis como agentes de contraste no
diagnóstico e no tratamento do câncer. Neste trabalho avaliamos a aplicação do fluido
magnético contendo nanopartículas de magnetita estabilizadas pelo recobrimento com ácido
dimercaptosuccínico (FM-DMSA), em meio aquoso, como meio de contraste em medicina
nuclear e em tomografia computadorizada. A aplicação em medicina nuclear envolveu a
realização de estudos radioquímicos e a aquisição de imagens in vivo de ratos. Os estudos
radioquímicos revelaram que aproximadamente 31% do tecnécio permaneceu na forma livre,
não se ligando totalmente ao composto FM DMSA, comprometendo a localização do
composto nos diferentes órgãos do animal. A aplicação das nanopartículas em tomografia
computadorizada foi realizada utilizando-se um objeto simulador de cabeça onde foram
dispostas seringas que continham diferentes volumes de FM-DMSA e iodo, diluídos em água,
a fim de comparar o contraste na imagem gerada por estes dois compostos. Os resultados
obtidos evidenciaram que a atenuação pelo FM-DMSA é aproximadamente cinco vezes
menor que os valores obtidos para o iodo. Embora a atenuação produzida pelo composto FMDMSA
seja menor que a produzida pelo iodo, esse composto apresenta propriedades
favoráveis para aplicações como meio de contraste em tomografia computadorizada, pois o
seu número atômico efetivo é muito maior que o número atômico de tecidos moles e os
valores de HU(Unidades de Hounsfield) produzidos na imagem estão na faixa daqueles
observados para tecidos ósseos.
|