• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

The Interactions of Plasma with Low-k Dielectrics: Fundamental Damage and Protection Mechanisms

Behera, Swayambhu Prasad 08 1900 (has links)
Nanoporous low-k dielectrics are used for integrated circuit interconnects to reduce the propagation delays, and cross talk noise between metal wires as an alternative material for SiO2. These materials, typically organosilicate glass (OSG) films, are exposed to oxygen plasmas during photoresist stripping and related processes which substantially damage the film by abstracting carbon, incorporating O and OH, eventually leading to significantly increased k values. Systematic studies have been performed to understand the oxygen plasma-induced damage mechanisms on different low-k OSG films of various porosity and pore interconnectedness. Fourier transform infrared spectroscopy, x-ray photoelectron spectroscopy and atomic force microscopy are used to understand the damage kinetics of O radicals, ultraviolet photons and charged species, and possible ways to control the carbon loss from the film. FTIR results demonstrate that O radical present in the plasma is primarily responsible for carbon abstraction and this is governed by diffusion mechanism involving interconnected film nanopores. The loss of carbon from the film can be controlled by closing the pore interconnections, He plasma pretreatment is an effective way to control the damage at longer exposure by closing the connections between the pores.
2

Integrated, Intelligent Sensor Fabrication Strategies for Environmental Monitoring

Suzuki, Takeharu, n/a January 2004 (has links)
The humidity, temperature, wind speed/direction micro sensors can be manufactured individually, resulting in three individual substrates. The integration of the three sensors into a single substrate is a vital challenge to achieve an integrated intelligent sensor so called a multiple sensor. This requires the integration of process flows and is a major challenge because adequate sensor performance must be maintained. Polyimide was selected as a humidity sensing material for its compatibility with conventional integrated circuit fabrication technology, negligible temperature dependence and good resistance against contamination. Nickel was selected for the temperature and wind speed/direction sensor because of its useful temperature coefficient and the advantage of its cost. Since the known wet etchant for nickel requires hard-baked photoresist, a method which does not attack the polyimide while removing the photoresist must be developed. The method developed for etching nickel employs hard-bake-free photoresist. Other challenge was ensuring good thermal isolation for the wind speed/direction sensor fabricated on a silicon nitride layer preformed on top of a silicon wafer. Since silicon acts as a good heat sink, the silicon under the sensor was etched entirely away until the silicon nitride layer was reached. This structure achieved good thermal isolation resulting in small power consumption. This low power feature is essential for sensors deployed in fields where power access or replacement of power sources is restricted. This structure was compared with the structure created by polyimide plateau on a silicon nitride layer coated on a silicon substrate as a function of power consumption. Based on the examination of thermal isolation, the multiple sensor utilizing a MEMS technique was fabricated with a single-sided mask aligner. The characteristics of humidity sensors fabricated with polyimide were examined in detail with respect to variations of electrode structures, improvement of sensitivity, effect of process temperature, temperature and frequency dependence, and stability. The humidity sensor constructed with O2 plasma treated polyimide resulted an improvement in sensitivity and hysteresis. The investigation using XPS, FTIR and AFM concluded the chemical modification of polyimide played an important role in this improvement. The design, fabrication and results of a series of humidity sensors are quantified. There is always no unique packaging solution for sensors because of the application-specific nature of the sensors. This intelligent environmental monitoring system was designed to accommodate both an environmental sensor and its signal conditioning electronics circuitry (SICONEC) into a single package. The environmental sensors need direct exposure to the environment while SICONEC needs a sealed encapsulation to avoid environmental damage. A new style of packaging addressing these requirements was demonstrated using a hot embossing machine. The hot embossing machine was used to embed an integrated circuit (IC) in a bare die condition into a polycarbonate (PC) sheet. In this case, the IC was flipped down against the PC, which protects the front side of the IC from the environmental damages. In a test phase, a die containing operational amplifiers was embossed into the PC. A humidity sensor and surface mount resisters were placed on the same surface of the PC to test the validity of this new technique. Interconnection between the embossed die and the humidity sensor was established using bonding wires. Copper tracks were also used to ensure all electrical connections for the die, the humidity sensor and the resistors. The results clarified the method developed. Details of process methods, issues and further potential improvement are reported.
3

Microfabrication of Plasmonic Biosensors in CYTOP Integrating a Thin SiO2 Diffusion and Etch-barrier Layer

Hanif, Raza 18 April 2011 (has links)
A novel process for the fabrication of Long Range Surface Plasmon Polariton (LRSPP) waveguide based biosensors is presented herein. The structure of the biosensor is comprised of Au stripe waveguide devices embedded in thick CYTOP claddings with a SiO2 solvent diffusion barrier and etch-stop layer. The SiO2 layer is introduced to improve the end quality of Au waveguide structures, which previously deformed during the deposit of the upper cladding process and to limit the over-etching of CYTOP to create micro-fluidic channels. The E-beam evaporation method is adapted to deposit a thin SiO2 on the bottom cladding of CYTOP. A new micro-fluidic design pattern is introduced. Micro-fluidic channels were created on selective Au waveguides through O2 plasma etching. The presented data and figures are refractive index measurements of different materials, thickness measurements, microscope images, and AFM images. Optical power cutback measurements were performed on fully CYTOP-cladded symmetric LRSPP waveguides. The end-fire coupling method was used to excite LRSPP modes with cleaved polarization maintaining (PM) fibre. The measured mode power attenuation (MPA) was 6.7 dB/mm after using index-matched liquid at input and output fibre-waveguide interfaces. The results were compared with the theoretical calculations and simulations. Poor coupling efficiency and scattering due to the SiO2 are suspected for off-target measurements.
4

Microfabrication of Plasmonic Biosensors in CYTOP Integrating a Thin SiO2 Diffusion and Etch-barrier Layer

Hanif, Raza 18 April 2011 (has links)
A novel process for the fabrication of Long Range Surface Plasmon Polariton (LRSPP) waveguide based biosensors is presented herein. The structure of the biosensor is comprised of Au stripe waveguide devices embedded in thick CYTOP claddings with a SiO2 solvent diffusion barrier and etch-stop layer. The SiO2 layer is introduced to improve the end quality of Au waveguide structures, which previously deformed during the deposit of the upper cladding process and to limit the over-etching of CYTOP to create micro-fluidic channels. The E-beam evaporation method is adapted to deposit a thin SiO2 on the bottom cladding of CYTOP. A new micro-fluidic design pattern is introduced. Micro-fluidic channels were created on selective Au waveguides through O2 plasma etching. The presented data and figures are refractive index measurements of different materials, thickness measurements, microscope images, and AFM images. Optical power cutback measurements were performed on fully CYTOP-cladded symmetric LRSPP waveguides. The end-fire coupling method was used to excite LRSPP modes with cleaved polarization maintaining (PM) fibre. The measured mode power attenuation (MPA) was 6.7 dB/mm after using index-matched liquid at input and output fibre-waveguide interfaces. The results were compared with the theoretical calculations and simulations. Poor coupling efficiency and scattering due to the SiO2 are suspected for off-target measurements.
5

Microfabrication of Plasmonic Biosensors in CYTOP Integrating a Thin SiO2 Diffusion and Etch-barrier Layer

Hanif, Raza 18 April 2011 (has links)
A novel process for the fabrication of Long Range Surface Plasmon Polariton (LRSPP) waveguide based biosensors is presented herein. The structure of the biosensor is comprised of Au stripe waveguide devices embedded in thick CYTOP claddings with a SiO2 solvent diffusion barrier and etch-stop layer. The SiO2 layer is introduced to improve the end quality of Au waveguide structures, which previously deformed during the deposit of the upper cladding process and to limit the over-etching of CYTOP to create micro-fluidic channels. The E-beam evaporation method is adapted to deposit a thin SiO2 on the bottom cladding of CYTOP. A new micro-fluidic design pattern is introduced. Micro-fluidic channels were created on selective Au waveguides through O2 plasma etching. The presented data and figures are refractive index measurements of different materials, thickness measurements, microscope images, and AFM images. Optical power cutback measurements were performed on fully CYTOP-cladded symmetric LRSPP waveguides. The end-fire coupling method was used to excite LRSPP modes with cleaved polarization maintaining (PM) fibre. The measured mode power attenuation (MPA) was 6.7 dB/mm after using index-matched liquid at input and output fibre-waveguide interfaces. The results were compared with the theoretical calculations and simulations. Poor coupling efficiency and scattering due to the SiO2 are suspected for off-target measurements.
6

Microfabrication of Plasmonic Biosensors in CYTOP Integrating a Thin SiO2 Diffusion and Etch-barrier Layer

Hanif, Raza January 2011 (has links)
A novel process for the fabrication of Long Range Surface Plasmon Polariton (LRSPP) waveguide based biosensors is presented herein. The structure of the biosensor is comprised of Au stripe waveguide devices embedded in thick CYTOP claddings with a SiO2 solvent diffusion barrier and etch-stop layer. The SiO2 layer is introduced to improve the end quality of Au waveguide structures, which previously deformed during the deposit of the upper cladding process and to limit the over-etching of CYTOP to create micro-fluidic channels. The E-beam evaporation method is adapted to deposit a thin SiO2 on the bottom cladding of CYTOP. A new micro-fluidic design pattern is introduced. Micro-fluidic channels were created on selective Au waveguides through O2 plasma etching. The presented data and figures are refractive index measurements of different materials, thickness measurements, microscope images, and AFM images. Optical power cutback measurements were performed on fully CYTOP-cladded symmetric LRSPP waveguides. The end-fire coupling method was used to excite LRSPP modes with cleaved polarization maintaining (PM) fibre. The measured mode power attenuation (MPA) was 6.7 dB/mm after using index-matched liquid at input and output fibre-waveguide interfaces. The results were compared with the theoretical calculations and simulations. Poor coupling efficiency and scattering due to the SiO2 are suspected for off-target measurements.

Page generated in 0.0522 seconds