251 |
Análise da precisão de guias prototipados na transferência do planejamento virtual em implantodontiaWoitchunas, Gilséia Fernanda Petry January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:16Z (GMT). No. of bitstreams: 2
000400750-0.pdf: 3101518 bytes, checksum: e6af479d16d5fa9302f205b0fc307429 (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Planning systems based on digital tomographic images allow the surgeon to select the most adequate sites for placement of dental implants, considering the specific anatomic characteristics of patients and the bone structure of areas of interest. Though very important, the transference of computerized planning of implants to the surgical site is still hardly accurate. This study was conducted on 11 human dry mandibles to compare the planned position and angulation of dental implants and the results of procedures performed, considering the accuracy of virtual planning performed on the relationship with digital CT images obtained after implant placement. Superimposition of images of planned dental implants on the final images was processed on a computer for evaluation of the distances and angulations in relation to the implant long axis. Application of the Student’s t test for comparison of samples with zero reference value revealed statistically significant difference for the linear and angular measurements analyzed, indicating the need of further studies to investigate the applicability of this new technical routine in the clinical practice of Implantology. / Os sistemas de planejamento, baseados em imagens tomográficas digitais, permitem ao profissional selecionar os locais mais adequados para a colocação de implantes dentários, levando em consideração as características anatômicas específicas de pacientes e a estrutura óssea das áreas de interesse. A transferência do planejamento de implantes realizado em computador para o campo cirúrgico, apesar de muito importante, permanece como um procedimento difícil de ser executado com precisão. Nesta pesquisa, realizou-se um estudo comparativo entre posição e angulação planejadas para implantes dentários e os resultados obtidos após a execução dos procedimentos. Para isso, utilizou-se 11 mandíbulas humanas secas, levando-se em consideração a precisão do planejamento virtual realizado. A sobreposição das imagens dos implantes dentários planejados sobre aquelas do que foi executado, recebeu processamento computadorizado e, então, avaliação quanto às distâncias aferidas e às angulações em relação ao longo-eixo destes implantes. Ao se aplicar o teste t de Student para comparar as amostras com um valor de referência zero, verificaram-se diferenças estatisticamente significativas para as medidas lineares e angulares analisadas, indicando a necessidade de estudos complementares que verifiquem a aplicabilidade desta nova rotina técnica na prática clínica de Implantodontia.
|
252 |
Clareamento vital com diferentes agentes clareadores e fontes ativadoras: estudo in vivoCarracho, Helena Gluer January 2007 (has links)
Made available in DSpace on 2011-12-27T14:14:17Z (GMT). No. of bitstreams: 2
000397761-0.pdf: 1553234 bytes, checksum: 86a4e306eea4ffb8281cd56ed22ec5c9 (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this clinical trial, double-blind and randomized, was to compare two whitening treatments: home and professional to placebo evaluating shade, sensibility and periodontal status. Forty five patients were divided into three groups (n=15): Group 1 – 10% carbamide peroxide, Group 2 – placebo (carbopol), Group 3 – 35% hydrogen peroxide + Q-switch I dye + carbopol + Nd:YAG laser. The patients from groups 1 and 2 used the whitening agents in trays for three weeks. The group 3 received the Nd:YAG laser irradiation with the following protocol: 2. 0W, 100 mJ, 20 pps. The shade evaluation was realized by two examiners through a Vita Classic scale. The sensibility and periodontal status were accessed by scales made by researchers. For each group the initial and final shade was statistically analyzed by Wilcoxon Rank test (p<0. 05) and in the comparison among groups was applied the Kruskal-Wallis and Mann-Whitney tests. There was statistical significance to the initial and final shade for groups 1 and 3, being the shade’s level variation, in according to Vita’s scale, of 8. 14 and 7. 80, respectively. The groups 1 and 3 were no statistically different from each other but differ from group 2. There were no statistical differences between the initial and final sensibility for all groups. However, the groups 1 and 3 were statistically different from group 2 in the final sensibility presenting higher values. There were no statistical differences between the initial and final periodontal status for all groups and between groups. In conclusion, both bleaching techniques, 35% hydrogen peroxide with Nd:YAG laser or 10% carbamide peroxide, were efficient to shade alteration with teeth whitening promoting minimal collateral effects on periodontal tissues and sensibility. / O objetivo deste ensaio clínico, duplo-cego e randomizado foi comparar dois tratamentos de clareamento: caseiro e de consultório com laser de Nd:YAG a um placebo; avaliando cor, sensibilidade e condições periodontais. Quarenta e cinco pacientes foram divididos em 3 grupos (n=15): Grupo 1- peróxido de carbamida a 10%, Grupo 2- placebo (carbopol) e Grupo 3- peróxido de hidrogênio 35% + corante Q-Switch I + carbopol + laser de Nd:YAG. Os pacientes dos grupos 1 e 2 usaram o gel em moldeiras por 3 semanas. Os pacientes do grupo 3 receberam 3 aplicações, 1 por semana, do agente clareador e laser de Nd:YAG com os parâmetros de 2. 0W, 100 mJ, 20 pps. A avaliação da cor foi realizada por dois examinadores através da escala Vita Classic. A sensibilidade e o periodonto foram avaliados através de escalas elaboradas pelos pesquisadores. A análise estatística dos valores iniciais e finais de cada grupo foi realizada através do teste de Wilcoxon (p<0,05) e a comparação entre os grupos foi realizada com o teste de Kruskal Wallis e Mann-Whitney (p<0,05). Houve diferença significativa entre a cor inicial e final nos grupos 1 e 3, sendo que a variação de níveis, conforme escala Vita, foi de 8,14 e 7,80, respectivamente. Os grupos 1 e 3 não diferiram entre si quanto à cor final (p>0,05), porém diferiram do grupo 2. Quanto à sensibilidade, não houve diferença estatística entre o clareamento inicial e final em todos os grupos testados (p>0,05). Na comparação entre os grupos em relação à sensibilidade, os grupos 1 e 3 apresentaram valores estatisticamente superiores ao 2 (p<0,05). Não foram observadas alterações periodontais significativas entre os valores iniciais e finais nos grupos estudados. Não houve diferença significativa entre os grupos em relação às alterações periodontais. Conclui-se que ambas as técnicas de clareamento, peróxido de carbamida a 10% e peróxido de hidrogênio a 35%, foram eficazes quanto à mudança de cor e promoveram mínimos efeitos colaterais sobre o periodonto e sensibilidade.
|
253 |
Análise comparativa da precisão de adaptação entre componentes UCLA e implante de um mesmo sistemaBondan, João Lopes January 2007 (has links)
Made available in DSpace on 2011-12-27T14:14:20Z (GMT). No. of bitstreams: 2
000390167-0.pdf: 8479233 bytes, checksum: 78f267d7711851d94f32594d0a86c23d (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to evaluate the fit between the components UCLA and implant of the same system (Neodent). The comparison was made through an evaluation of the vertical and horizontal gaps present at the interface between implant and UCLA, through scanning electronic microscopy (SEM), measurements in selected locations. Statistical analysis was done through variance analysis procedure (Anova-Oneway) and Tukey´s posterior procedure, with a significance level of 5%. The results pointed the UCLA components present significant differences in many evaluated aspects. Such differences might have some influence in the use of these components, both in clinical results and in its predictability. / O objetivo deste estudo foi avaliar a precisão de adaptação entre componentes UCLA e implante de um mesmo sistema (Neodent). A análise foi através da avaliação da fenda vertical e da discrepância horizontal da interface implante-UCLA por microscopia eletrônica de varredura (MEV), das mensurações em locais indicados. Para a comparação dos resultados, foi utilizado o procedimento de análise de variância (Anova-Oneway) e o procedimento posterior de Tukey, ao nível de significância de 5%. Os resultados mostraram que os componentes UCLA avaliados possuem diferenças significantes em diversos pontos avaliados. Essa variabilidade nos resultados podem interferir na eficácia de uso desses componentes, nos resultados clínicos e na sua previsibilidade.
|
254 |
Inclusão de digluconato de clorexidina em cimentos de ionômero de vidro para cimentação: análise das propriedades mecânicas e ação antibacterianaFarret, Marcel Marchiori January 2010 (has links)
Made available in DSpace on 2011-12-27T14:14:23Z (GMT). No. of bitstreams: 2
000425709-0.pdf: 2405069 bytes, checksum: 9669f0d9b3993fb98993324b4f6880c9 (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The orthodontic treatment predisposes the plaque accumulation due to the difficult of the oral hygiene and due to the great amount of sites to bacterial proliferation around brackets and manly bands. Therefore, the aim of this study was added chlorhexidine digluconate (CHD) into the conventional glass ionomer cements (GICs) and analyze mechanical properties and antibacterial effects. Two GICs were used: Ketac cem easy mix® (3M/ESPE, St. Paul, MN, USA) and Meron® (Voco, Cuxhaven, GR). The materials were manipulated in their normal composition (controls) and with two aqueous solutions containing tartaric acid and CHD (patent application requested to INPI on 05/04/2010 with provisory number 020100029358) instead of the original liquid (experimentals), to create a total of six groups. For the mechanical properties analyses were performed the tests of diametral tensile strength (DTS), compressive strength (CS), microhardness (MIC) and shear bond strength (SBS). To verify the antibacterial effects were measured the inhibition zones of the six groups of materials against Streptococcus mutans colonies grown over agar plates at periods of 5, 45 and 65 days. For the statistical analyses of the mechanical tests was used one-way analyses of variance (ANOVA) and Tukey multiple comparison test and for the culture tests was used the non parametric tests of Kruskal-Wallis, Mann-Whitney and Friedman, with significance level set at 5%. The results shown that there was no significant difference for the DTS, CS and SBS between controls groups and experimental groups with CHD (P >. 05). The microhardness showed improve for the two GICs with the addition of CHD with significant difference for the Ketac cem (P <. 05). There was significant inhibition of bacterial growth even at 65 days of analyses in the groups with the addition of CHD (P <. 05).With the results obtained is possible conclude that the addition of CHD into the GICs for the band cementation does not change negatively mechanical properties of the materials and provides increase in antibacterial effects in long-term. Therefore, it could be a material of choice in orthodontic treatment. / O tratamento ortodôntico predispõe o acúmulo de placa pela dificuldade de higiene por parte dos pacientes e pela grande quantidade de sítios para a proliferação bacteriana próximos aos bráquetes e principalmente anéis. Com base nisso, o objetivo deste estudo foi incluir digluconato de clorexidina (DGC) em cimentos de ionômero de vidro (CIVs) convencionais utilizados para a cimentação de anéis e verificar suas propriedades mecânicas e ação antibacteriana. Foram utilizados dois CIVs convencionais: Ketac cem easy mix® (3M/ESPE, St. Paul, MN, EUA) e Meron® (Voco, Cuxhaven, AL). Os materiais foram manipulados em suas formulações originais e com duas soluções aquosas contendo ácido tartárico e DGC (pedido de patente solicitado ao INPI em 05/04/2010 nº provisório 020100029358) em substituição aos líquidos provenientes de fábrica, formando ao total seis grupos. Para a análise das propriedades mecânicas foram realizados os teste de resistência à tração diametral (RTD), resistência à compressão (RC), microdureza (MIC), e resistência de união ao cisalhamento (RCS). Para a análise da ação antibacteriana foi avaliada a inibição de crescimento de colônias de Streptococcus mutans em placas de agar dos seis grupos de materiais em períodos de 5, 45 e 65 dias. Para a análise estatística dos testes mecânicos foi utilizada a análise de variância (ANOVA) complementada pelo teste de Tukey e para a cultura bacteriana os testes não paramétricos de Kruskal-Wallis, Mann-Whitney e Friedman, ao nível de significância de 5%. Os resultados demonstraram que não houve diferença significativa para os testes de RTD, RC e RCS entre os grupos sem adição de clorexidina e com a adição (p > 0,05).A microdureza dos dois materiais apresentou aumento com adição de clorexidina com diferença significativa para o Ketac Cem easy mix® (p < 0,05). Houve inibição significativa de crescimento bacteriano até o período de 65 dias nos grupos com adição de clorexidina (p < 0,05). Com base nos resultados obtidos é possível concluir que a adição de DGC em CIVs para a cimentação de bandas não altera negativamente as propriedades mecânicas destes materiais e proporciona ação antibacteriana considerável a longo prazo, podendo ser um material de escolha na clinica ortodôntica.
|
255 |
Influência da largura do cinzel utilizado em ensaio mecânico de cisalhamento sobre a resistência da uniãoOliveira, Antônio Carlos Castellan de January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:29Z (GMT). No. of bitstreams: 2
000406879-0.pdf: 817502 bytes, checksum: a388f3f8f4ce8e84782dbb5d5932a532 (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was compare the chisel width in shear bond strength test in dental/composite interface. For the shear bond test, chisels with 0. 5, 1, 2 and 3mm width were used to test four groups (n=15). Sixty bovine incisors were used, imbedded and flattened according to the methodology of Goes (1994) in order to prepare the samples. Enamel surfaces were flattened and etched with 15% phosphoric acid (3M/ESPE) with 15%, followed by application of Single Bond (3M/ESPE) adhesive system and Z-250 (3M/ESPE) composite resins according to manufacture’s instructions. To the shear bond strength, an universal testing machine EMIC DL 2000 (EMIC) at 0. 5 mm/min cross-head speed. Obtained data were compared statistically with analysis of variance and Duncan’s test with significance level of 5% (p < 0. 05) and submitted to Pearson’s correlation test (p < 0. 01). The averages in megapascal recorded were: 0. 5 mm – 19. 66; 1. 0 mm – 18. 78; 2 mm – 16. 77; 3 mm – 16. 06.There was a significantly difference between groups, when submitted to analysis of variance (p = 0. 045) and multiple comparison of Duncan’s test. The lower average (MPa) was recorded for chisel with 3 mm (16. 06), while the highest average (MPa) was recorded for the group with 0. 05 mm chisel (19. 66), that were statistically different. The correlation between chisel width and shear bond strength was significant (p < 0. 01). The obtained results allow conclude that shear bond strength (MPa) is influenced by chisel width used in the test. / O objetivo deste estudo foi comparar diferentes larguras de cinzel utilizadas em ensaios mecânicos para avaliação da resistência de união ao cisalhamento na interface esmalte dental / resina composta. Para a realização do ensaio e cisalhamento, cinzéis com larguras de 0,5mm, 1,0 mm, 2,0 mm e 3,0 mm foram utilizados para testar 4 grupos (n=15). Foram utilizados 60 dentes bovinos do grupo incisivo que tiveram sua inclusão, preparo de superfície e confecção dos corpos de prova realizados de acordo com Goes (1994). As superfícies de esmalte foram planificadas, condicionadas com ácido fosfórico (3M/ESPE) à 15%, seguido da aplicação do sistema adesivo Single Bond (3M) e de resina composta Z-250 (3M) conforme instruções do fabricante. Para o ensaio de cisalhamento foi utilizada uma máquina de ensaio universal EMIC DL 2000 (EMIC, BRASIL) a velocidade de 0,5mm/min. Os dados obtidos foram comparados estatisticamente com análise de variância e teste de Duncan com nível de significância de 5% (p < 0,05) e submetidos ao teste de correlação de Pearson (p < 0,01). As médias obtidas em Megapascal para a resistência de união ao cisalhamento foram: 0,5mm - 19,66; 1,0mm – 18,78; 2,0 mm – 16,77; 3,0 mm – 16,06. Houve diferença estatisticamente significativa entre os grupos, quando submetidos à análise de variância (p = 0,045) e testes de comparação múltipla de Duncan. A menor média (MPa) foi registrada para o grupo com cinzel de 3,0mm (16,06), enquanto a maior média (MPa) foi verificada para o grupo com cinzel de 0,5mm (19,66), que diferiram estatisticamente. A correlação entre largura do cinzel e resistência de união foi significante (p < 0,01). Os resultados obtidos permitem concluir que os valores (MPa) de resistência de união ao cisalhamento sofrem influência da largura do cinzel utilizado no ensaio.
|
256 |
Avaliação da dureza e rugosidade superficial de material reembasador resiliente submetido a agente químico de limpeza e a escovação simuladaBeck Neto, Joaquim Luiz de Lima January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:41Z (GMT). No. of bitstreams: 2
000425710-0.pdf: 4733060 bytes, checksum: bc9a4ed427f2b79c5adf0d601bc1a8ca (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The objectives of the present study in vitro were to evaluate and compare the Shore A roughness and hardness of a tissue conditioner material (Ufi Gel P) submitted to abrasion test by brushing, with and without the application of surface sealer (Ufi Gel P), disinfected or not with sodium hypochlorite 2,5% up to 28 days. For the confection of the samples, the conditioner tissue material was applied in a 2 mm in thickness, over an acrylic resin bar chemically activated (JET). Thirty samples of the Ufi Gel P material (2 mm in thickness) were manufactured on the acrylic resin bar and they were randomly divided in 3 groups (n=10) according with the treatment: Ufi Gel P with control seal (Group 1); Ufi Gel P with seal, disinfected with sodium hypochlorite 2. 5% for 28 minutes, every seven days (Group 2); and Ufi Gel P without seal, disinfected with sodium hypochlorite 2. 5% for 28 minutes, every seven days (Group 3). All three groups were stored in artificial saliva in a heater at 37°C during 28 days. The Shore A rugosity and hardness were measured in time initial, 7, 14, 21 and 28 days. The measures of the average roughness (Ra) were record with a rugosimeter SJ 201 (Mitutoyo) and the ones concerning hardness, through a Teclok Shore A durometer. The results were analyzed by ANOVA and Tukey ( =0,05). Analysing the results for rugosity throughout all 28 days to groups 1, 2 and 3, we can say that no variation was statistically significant among the different amounts of time in all groups submitted to a Variance Analysis. Comparing the hardness average among the groups and the different amounts of time, a statistically significant variation was observed (p<0. 05). Thus, we can conclude that the values of rugosity were not altered a in a 28 days period (p>0,05); and also, that the tissue conditioner material increases significantly in hardness in the first 21 days, and after this period it seems to become stable (p>0,05). / Os objetivos deste estudo in vitro, foram avaliar e comparar a rugosidade e a dureza Shore A de um material reembasador resiliente (Ufi Gel P) submetido à escovação simulada com e sem aplicação de seu selante de superfície (Ufi Gel P), desinfetados ou não com hipoclorito de sódio 2,5% em até 28 dias. Para confecção das amostras, o material reembasador resiliente foi aplicado em uma espessura de 2 mm sobre uma barra de resina acrílica ativada quimicamente (JET). Foram confeccionados 30 amostras do material Ufi Gel P (2 mm de espessura) sobre a barra de resina acrílica e divididos aleatoriamente em 3 grupos (n=10) de acordo com o tratamento aplicado: Ufi Gel P com selante (Grupo 1); Ufi Gel P com selante submetido à desinfecção com hipoclorito de sódio 2,5% por 28 minutos, a cada 7 dias (Grupo 2); Ufi Gel P sem selante submetido à desinfecção com hipoclorito de sódio 2,5% por 28 minutos, a cada 7 dias (Grupo 3). Os 3 grupos foram armazenados em saliva artificial em estufa á 37°C durante 28 dias. A rugosidade e dureza Shore A foram verificados no tempo inicial, 7, 14, 21, 28 dias. As medidas da rugosidade média (Ra) foram realizadas com um rugosímetro SJ 201 (Mitutoyo) e as de dureza através de um durômetro Teclok Shore A. Os resultados foram analisados com ANOVA e Tukey ( =0,05). Analisando os resultados de rugosidade (Ra) ao longo dos 28 dias pode-se observar que não houve diferença estatisticamente significante entre os tempos e entre os grupos quando submetidos à Análise de Variância (p>0,05). Ao comparar as médias de dureza entre os grupos e entre tempos, houve diferença estatisticamente significante (p<0,05).Assim, pode-se concluir que os valores de rugosidade não se alteraram nos 28 dias (p>0,05) e que o material condicionador de tecido tem um aumento significativo nos valores de dureza nos primeiros 21 dias, não havendo diferença significante após este período (p>0,05).
|
257 |
Influência do tempo de armazenamento na rugosidade, tração diametral e compressão de gessos odontológicosCesero, Leonardo de January 2013 (has links)
Submitted by Ginamara Lima (ginaj@pucrs.br) on 2013-03-20T19:14:18Z
No. of bitstreams: 1
446374.pdf: 760995 bytes, checksum: fdb1e9bc7072bab1285303e1a7f13c42 (MD5) / Made available in DSpace on 2013-03-20T19:14:18Z (GMT). No. of bitstreams: 1
446374.pdf: 760995 bytes, checksum: fdb1e9bc7072bab1285303e1a7f13c42 (MD5) / O tempo de espera para a remoção dos modelos de gesso dos moldes em relação a sua resistência mecânica é controverso. O objetivo desse trabalho foi avaliar a influência do tempo de armazenamento na rugosidade, tração diametral e compressão de gessos tipo IV. Foram confeccionadas 270 amostras, sendo 90 para cada marca comercial (Durone, Fuji Rock e Tuff Rock). Os testes de rugosidade, tração diametral e compressão para os tempos de armazenagem de 1 hora, 24 horas e 7 dias foram realizados. Para os testes de rugosidade superficial e tração diametral amostras de 6 mm de diâmetro por 3 mm de altura foram confeccionados. Para o teste de compressão amostras de 3 mm de diâmetro por 6 mm de altura foram utilizadas. Foi utilizado um rugosímetro, para a medição da rugosidade média de superfície (Ra). Os corpos de prova foram montados na máquina de ensaio universal e posteriormente realizados os testes de tração diametral e compressão nos respectivos tempos. Os resultados foram submetidos ao modelo linear geral e teste de Tukey (α=0,05). Os valores de rugosidade registrados para os diferentes tipos de gesso variaram de 0,30 μm (Durone 1 hora) à 0,64 μm (Tuff Rock 7 dias). Os valores de tração diametral registrados para os diferentes tipos de gesso variaram de 3,94 MPa (Tuff Rock 1 hora) à 9,20 MPa (Durone 7 dias). Os valores de compressão registrados para os diferentes tipos de gesso variaram de 26,67 MPa (Durone 1 hora) à 65,14 MPa (Fuji Rock 7 dias). Concluímos que houve um aumento estatisticamente significante para o fator tempo em relação a rugosidade (p=0,005), tração diametral (p=0,001) e compressão (p=0,001). O fator marca comercial influenciou significativamente na rugosidade (p=0,001), tração diametral (p=0,004) e compressão (p=0,001). O gesso Tuff Rock apresentou maior rugosidade, os gessos Durone e Fuji Rock apresentaram o maior valor à tração diametral e o gesso Fuji Rock o maior valor a compressão. / The post pouring time to remove dental stone from impression is controversial regardless to strength and roughness. The aim of this study was evaluate the influence of post pouring time in the surface roughness, compressive and diametral tensile strength (DTS) of type IV dental stone. Two hundred and seventy dental stone samples were made from three commercial brands (Durone, Fuji Rock and Tuff Rock). Surface roughness, compressive and diametral tensile strength tests were performed 1 hour, 24 hours and 7 days after pouring. Samples of 6 mm in diameter and 3 mm in height were produced for roughness and DTS tests. Samples of 3 mm in diameter and 6 mm in height were used for compressive strength. Results were submitted to the general linear model and Tukey test (α=0.05). The surface roughness (Ra) registered to different types of dental stone vary from 0.30 μm (Durone 1 hour) to 0.64 μm (Tuff Rock 7 days). The diametral tensile strength (MPa) ranged from 3.94 (Tuff Rock 1 hour) to 9.20 (Durone 7 days). For compressive strength (MPa), data vary from 26.67 MPa (Durone 1 hour) to 65.14 MPa (Fuji Rock 7 days). There was a significant increase of surface roughness (p=0.005), diametral tensile strength (p=0.001) and compressive strength (p=0.001) as time passes after pouring. Commercial brand factor influenced roughness (p=0.001), diametral tensile strength (p=0.004) and compressive strength (p=0.001). Tuff Rock showed the highest surface roughness. The highest DTS was recorded for Durone and Fuji Rock. Fuji Rock showed the highest compressive strength.
|
258 |
Influência dos cimentos resinosos na deflexão de cúspides de pré-molares tratados endodonticamente e restaurados com inlays em resina compostaRosa, Helen Cristina Vieira da January 2013 (has links)
Submitted by Ginamara Lima (ginaj@pucrs.br) on 2013-04-17T12:23:34Z
No. of bitstreams: 1
447190.pdf: 575465 bytes, checksum: 907bc1dd4c8788ff1bcb0479b1249fc5 (MD5) / Made available in DSpace on 2013-04-17T12:23:34Z (GMT). No. of bitstreams: 1
447190.pdf: 575465 bytes, checksum: 907bc1dd4c8788ff1bcb0479b1249fc5 (MD5) / O objetivo desse trabalho foi avaliar a influência de diferentes cimentos resinosos na deflexão de cúspides de dentes com tratamento endodôntico. Sessenta pré-molares superiores foram divididos aleatoriamente em cinco grupos (n=12): 1 - hígidos; 2 - cavidades; 3 - RelyX ARC; 4 - RelyX U100; 5 - SeT. Os dentes dos grupos 2, 3, 4 e 5 receberam preparos MOD e tratamento endodôntico. Os dentes dos grupos 3, 4 e 5 foram moldados com silicone por adição, seguido de vazamento de gesso tipo IV. Sobre cada modelo foi confeccionada uma restauração inlay em resina composta Z250. As restaurações foram cimentadas com os cimentos resinosos, de acordo com cada grupo experimental, seguindo as instruções dos fabricantes. Os corpos de prova foram armazenados em água destilada a 37º C por 72 horas. Em máquina de ensaio universal, uma carga de 200 N foi aplicada na região oclusal com esfera de aço de 8 mm de diâmetro e, com o auxílio de um micrômetro posicionado nas faces vestibular e palatina, a deflexão das cúspides foi medida antes e após a carga. Após 24 horas, foi realizado o mesmo procedimento aplicando uma carga de 300 N na região oclusal. De acordo com ANOVA e teste de Tukey (α=0,05), para ambas as cargas, o menor valor médio de deflexão de cúspides ocorreu no grupo dente hígido, diferindo estatisticamente dos demais grupos. O segundo menor valor foi obtido para o grupo RelyX ARC, seguido do grupo RelyX U100, os quais diferiram estatisticamente entre si. As maiores médias de deflexão de cúspides foram obtidas com o grupo SeT e o grupo dente com cavidade, não diferindo estatisticamente entre si. De acordo com o teste t-student para amostras pareadas (α=0,05), houve diferença estatística para a média de deflexão de cúspides entre as cargas de 200 N e 300 N para o grupo cavidade (p = 0,002), o grupo RelyX U100 (p = 0,000), e o grupo SeT (p = 0,004). Não houve diferença estatística para o grupo dente hígido (p = 0,389) e para o grupo RelyX ARC (p = 0,188). As inlays fixadas com RelyX ARC tiveram deflexão de cúspides inferior à obtida com os cimentos resinosos autoadesivos, sendo que o RelyX U100 proporcionou menor deflexão de cúspides em relação ao SeT. / The aim of this study was to evaluate the influence of different resin cements in the cuspal deflection of teeth with endodontic treatment. Sixty superior premolars were randomly divided into five (n=12) groups: 1 – sound teeth; 2 – cavity; 3 - Rely X ARC; 4 – RelyX U100; 5 – SeT. The teeth from groups 2, 3, 4 and 5 received a MOD preparation and endodontic treatment. Impressions were made with vinyl polysiloxane and poured using type IV die stone in groups 3, 4 and 5. Inlays with Z250 composite resin were built over each cast and luted with the resin cements according manufacturer’s instructions. The specimens were stored in distilled water at 37o C for 72 hours. The specimens were positioned in a universal testing machine and a load of 200 N was applied in the oclusal region with a steel rod with 8 mm in diameter. The cusp deflection was measured after and before the load by means a micrometer that contacted the buccal and palatine faces. After 24 h, the cuspal deflection was measured again using a load of 300 N. According to ANOVA and Tukey’s test ( α= 0.05), for both occlusal loads, the sound teeth presented the lowest mean cuspal deflection, differing statistically from the other groups. Intermediate values were obtained in RelyX ARC group and RelyX U100 group, differing statistically between them. The highest cuspal deflections were obtained in SeT group and cavity group, not differing statistically between them. According to the Student t-test, there was a statistically significant difference among the 200 N and 300 N occlusal loads for the cavity group (p = 0.002), RelyX U100 group (p = 0.000), and SeT group (p = 0.004). There was no statistical difference for the sound teeth group (p = 0.389), and RelyX ARC group (p = 0.188). The inlays luted with RelyX ARC obtained lower cuspal deflection in comparison with the self-adhesive resin cements; RelyX U100 showed lower cuspal deflection than SeT.
|
259 |
"A boca não existe" : saberes e práticas de trabalhadores da saúde comunitária sobre saúde bucal de idososFreire, Danielle Bianca de Lima January 2005 (has links)
Compreender que o indivíduo, no processo saúde - doença, deve ser avaliado de forma completa, reunindo saberes das diversas áreas e atuando de forma interdisciplinar, são características importantes para os profissionais de saúde, principalmente os que atuam na atenção primária - que representam a porta de entrada do serviço público de saúde. Este estudo tem como objetivo investigar os saberes e práticas de médicos e enfermeiros da atenção primária sobre a temática saúde bucal de idosos, interdisciplinaridade e educação em saúde. Este objetivo foi balisado pelo entendimento de que a temática saúde bucal deve permear vários campos. Na presente pesquisa, estas questões são estudadas em Unidades de Serviço de Atenção Primária pertencentes ao Serviço de Saúde Comunitária do Grupo Hospitalar Conceição. A pesquisa segue uma metodologia qualitativa, de caráter descritivo, em que é descrito o contexto das Unidades de Saúdeo em que trabalham os profissionais de saúde. Esses dados foram obtidos através de notas de campo, análise de documentos e textos. No segundo momento da investigação, faz-se a análise do conteúdo de 25 relatos de profissionais médicos, residentes de medicina e de enfermeiros, de ambos os sexos, coletados através de entrevistas semi-estruturadas. Das entrevistas, emergiram temas, categorias e subcategorias que, associadas aos dados da descrição do contexto, levaram a conclusão de que a saúde bucal do idoso ainda é um tema pouco abordado entre esses profissionais, os quais enfatizam principalmente a saúde bucal do público infantil. Considera-se, portanto, que a odontologia necessita encontrar estratégias para difundir, de forma interdisciplinar, a temática saúde bucal, especialmente a do idoso, como uma população em crescimento e que apresenta um acúmulo de necessidades de atenção não satisfeitas pela Odontologia durante a sua história.
|
260 |
Odontologia em saúde coletiva, sujeitos portadoresde necessidades especiais e a integralidade da atençãoMaia, Rodrigo Betti January 2003 (has links)
Com esse estudo objetivou-se analisar a possibilidade da aplicação do conceito de integralidade da atenção para sujeitos portadores de necessidades especiais. Enfocou-se o conceito de integralidade da atenção, submetendo-o a esse recorte da realidade, tanto pelo fato dele ser central à contemporânea discussão do que fazer em saúde pública, face a Reforma Sanitária Brasileira, bem como, por entendermos que a integralidade é praticamente a única alternativa para atenção desses sujeitos, tanto no método clínico como no coletivo de intervenção. A população alvo constou da família de sujeitos portadores de necessidades especiais que freqüentam a APAE do município de Lajeado, bem como dos trabalhadores daquela instituição. Verificou-se o discurso da referida população alvo sobre etiologia e prevenção da cárie dentária, doença periodontal, câncer de boca, má-oclusão e fissuras de lábio e palato, tentando identificar hábitos, valores e dificuldades que possam intermediar a possibilidade da aplicação do conceito de integralidade da atenção para sujeitos portadores de necessidades especiais. Concluiu-se que : • A utilização do conceito de integralidade é intermediado pelo saber ou não saber, pela cultura somática dos indivíduos; • A falta de um saber sobre saúde bucal que melhore o cotidiano dos sujeitos impede que se trabalhe com o conceito ampliado de cura, 9 que é fundante da noção de autonomia, que se agrega à noção de integralidade; • A família do sujeito especial e a instituição que o mesmo freqüenta são um locus privilegiado para a práxis da noção de integralidade da atenção; • O sujeito especial se constitui como sujeito com inteireza, somente a partir da adoção intencional do conceito de integralidade, quer na instituição, quer na família; • O corpo de trabalhadores da instituição deveria contar com o trabalho de um cirurgião dentista com especialidade em saúde pública, ou com uma técnica em higiene dental, para atuar junto às famílias e com os trabalhadores de forma intra e interdisciplinar; • Há uma necessidade premente de ações de educação em saúde e capacitação para as famílias e trabalhadores da instituição, no que tange à saúde bucal, enfocando as 5 patologias bucais que são tidas como problemas de saúde pública.
|
Page generated in 0.0506 seconds