• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Energiförbrukning för putsade, odränerade träregelväggar i fuktigt respektive torrt tillstånd

Arvidsson, Erik January 2009 (has links)
<p>In recent years, moisture damages have been noticed in rendered, undrained stud walls. The design is built on the principle one-stage tightening which means that there is no air gap in the construction. The damages have occurred when water has permeated through the rendering in leaking connections and fittings for windows, doors, canopies, balconies, terraces and awnings. Behind the plaster carrier, which consists of either polystyrene or rigid mineral wool, plasterboard has often been used as a wind protection barrier. In many cases the wind protection barrier and the underlying wooden studs have been exposed to mould and in some cases even rot. It has been shown that damp in the structure is difficult to dry out.</p><p>The aim of the thesis has been to examine how the energy consumption is affected when this type of construction is damp, partly because energy is required to dry up damp, partly because the insulation ability for a material decreases when it is affected by moisture.</p><p>Previous research and relevant literature has been used in this thesis, to provide: A comprehensive picture of the problem, an explanation for the calculations used and an understanding of the conclusions drawn.</p><p>The energy consumption has been calculated for 1 m<sup>2 </sup>wall area on two types of wall designs. The calculations have been performed in both dry and damp condition. To calculate the energy consumption in damp condition, three different types of calculation models have been used in three different ways. Since no measurements have been made, the calculations are to some extent based on assumed values.</p><p>The amount of damp that have entered the structure has, according to the calculation models used, been shown to produce small differences in energy consumption compared to the dry structure. The main problem for these types of walls seems instead to be the growth of microorganisms. Nevertheless, the microorganisms seem not to have affected the indoor environment in any significant manner.</p>
2

Energiförbrukning för putsade, odränerade träregelväggar i fuktigt respektive torrt tillstånd

Arvidsson, Erik January 2009 (has links)
In recent years, moisture damages have been noticed in rendered, undrained stud walls. The design is built on the principle one-stage tightening which means that there is no air gap in the construction. The damages have occurred when water has permeated through the rendering in leaking connections and fittings for windows, doors, canopies, balconies, terraces and awnings. Behind the plaster carrier, which consists of either polystyrene or rigid mineral wool, plasterboard has often been used as a wind protection barrier. In many cases the wind protection barrier and the underlying wooden studs have been exposed to mould and in some cases even rot. It has been shown that damp in the structure is difficult to dry out. The aim of the thesis has been to examine how the energy consumption is affected when this type of construction is damp, partly because energy is required to dry up damp, partly because the insulation ability for a material decreases when it is affected by moisture. Previous research and relevant literature has been used in this thesis, to provide: A comprehensive picture of the problem, an explanation for the calculations used and an understanding of the conclusions drawn. The energy consumption has been calculated for 1 m2 wall area on two types of wall designs. The calculations have been performed in both dry and damp condition. To calculate the energy consumption in damp condition, three different types of calculation models have been used in three different ways. Since no measurements have been made, the calculations are to some extent based on assumed values. The amount of damp that have entered the structure has, according to the calculation models used, been shown to produce small differences in energy consumption compared to the dry structure. The main problem for these types of walls seems instead to be the growth of microorganisms. Nevertheless, the microorganisms seem not to have affected the indoor environment in any significant manner.
3

Quality of CPTU : Analyses and comparison of data from commercial actors in Stockholm/Mälardalen

Kardan, Caesar January 2015 (has links)
CPTU is one of the most sophisticated geotechnical investigation methods. However, there is a large amount of uncertainties related to this method. The uncertainties depend on different types of factors, for instance lack of accuracy in performance and equipment. The objective of this master thesis is to compare the CPTU-results from a number of commercial actors in Stockholm/Mälardalen in order to analyze these results with respect to the current standards and guidelines. The comparison was made in order to highlight the difference in results which may appear due to different equipment, performance of the operator and evaluation method. Based on this, an invite was sent to the commercial actors in Stockholm/Mälardalen, resulting in the participation of five different commercial actors in this investigation. Execution in the field was conducted over a six week period. During this time 26 CPTU were performed in total in a small area in Hagby, Stockholm, by these different actors. Once the data was collected from all of the actors, the results were evaluated with the aid of the computer softwares Conrad and Excel. The main conclusions from this study are: Not one of the performed CPTU in this master thesis fulfills the requirements for CPT class 1 according to the European standards. The quality of the education of operators should be improved and geotechnical engineers and the clients need to be more familiar with CPTU. The evaluated results from different commercial actors differ, and this can depend on the choice of equipment and performance of the operator during penetration, but it can also depend on systematic errors in the cone penetrometers / CPTU-sonderingar är en av de mest sofistikerade undersökningsmetoderna för geoteknisk analys och bedömning. Det finns emellertid en hög grad av osäkerhet i denna metod. Osäkerheten beror på olika typer av faktorer, bland annat brist på noggrannhet i handhavande och utrustning. Syftet med detta examensarbete är att jämföra CPTU-resultat från de kommersiella aktörerna i Stockholm/Mälardalen för att senare analysera dessa resultat i förhållande till gällande ramverk och riktlinjer. Jämförelsen gjordes med avsikt att lyfta fram skillnaderna i resultat som kan uppstå på grund av olika utrustning, handhavande och utvärderingsmetod. Baserat på detta skickades en inbjudan till de kommersiella aktörerna i Stockholm/Mälardalen, vilket ledde till att fem olika kommersiella aktörer deltog i undersökningen. Utförande i fält genomfördes under en period på sex veckor. Under denna tid utfördes totalt 26 sonderingar i ett avgränsat område i Hagby, Stockholm, av dessa olika aktörer. När all data samlats in från alla aktörer utvärderades resultaten med hjälp av mjukvarorna Conrad och Excel. De viktigaste slutsatserna i denna studie är: Ingen utav de utförda CPTU-sonderingarna uppfyller kraven för CPT klass 1 enligt den europeiska standarden. Kvaliteten på utbildning av fältgeotekniker bör förbättras och geotekniska ingenjörer och även beställare bör bli mer bekanta med CPT. De utvärderade resultaten från de olika aktörerna skiljer sig åt, och detta kan bero på valet av utrustning och fältgeoteknikerns prestation vid sondering men det kan också bero på systematiska fel i de använda sonderna.

Page generated in 0.0526 seconds