• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • Tagged with
  • 7
  • 7
  • 6
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise da estabilidade de cor de botões de íris artificiais obtidos por diferentes técnicas e após o envelhecimento acelerado

Bannwart, Lisiane Cristina [UNESP] 23 April 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-04-23Bitstream added on 2014-06-13T20:18:38Z : No. of bitstreams: 1 000737733.pdf: 1813264 bytes, checksum: 5276c6bddbc491cf01ada48860d5d3d6 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / As próteses oculares são responsáveis pela recuperação da estética e auto-estima do usuário. As técnicas existentes para a confecção da prótese ocular devem resultar em íris artificiais perfeitamente estéticas com conseqüente dissimulação do defeito facial. Dessa forma, este estudo tem como propósito verificar a alteração de cor do botão de íris artificial entre diferentes técnicas após a polimerização e o envelhecimento acelerado. Foram confeccionadas 60 amostras simulando próteses oculares distribuídas em grupos (n=10) de acordo com a técnica utilizada, sendo: PE: técnica convencional sem verniz, PEV: técnica convencional com verniz, CA: técnica com calota pré-fabricada sem verniz, CAV: técnica com calota pré-fabricada com verniz, PI: técnica da pintura invertida sem verniz, PIV: técnica da pintura invertida com verniz. A leitura de cor foi realizada por meio de um espectrofotômetro de reflexão ultravioleta visível utilizando o sistema CIE L*a*b*, antes e após polimerização, e após 252, 504 e 1008 de envelhecimento acelerado. Os dados obtidos foram submetidos à análise de variância (ANOVA), e teste de Tukey (p<0,05). O teste de cor mostrou que após polimerização e envelhecimento acelerado todas as amostras apresentaram alteração significativa da cor, porém, as amostras com verniz protetor de tinta tiveram menor alteração em todos os períodos analisados. / Ocular prostheses are responsible not only for the recovery of aesthetic but also for the self-esteem of the anophthalmic patient. The techniques used to fabricate ocular prosthesis should result in artificial iris with adequate aesthetic and natural appearance. When such characteristics are not achieved, the fabrication of new prosthesis is indicated even in the presence of good fit of the old prosthesis. Additionally, the color instability of iris is the most relevant factor that affects the longevity of ocular prosthesis, and is related to the polymerization process of the acrylic resin and its clinical use over time. Therefore, the present study investigated the color alteration of artificial iris buttons obtained by different techniques after polymerization and accelerated aging. A total of 60 samples simulating an ocular prosthesis were fabricated and divided into groups (n=10) according to the technique used: PE – conventional technique without varnish; PEV - conventional technique with varnish; CA - Prefabricated cap technique without varnish; CAV - Prefabricated cap technique with varnished; PI - Reverse painting technique without varnish; PIV - Reverse painting technique with varnish. Color measurements were performed by using a visible ultraviolet reflection spectrophotometer with the CIE L*a*b* system, before and after polymerization, and after 252, 504 and 1008 hours of accelerated aging. Data were submitted to analysis of variance (ANOVA) and Tukey test (p<.05). After polymerization and accelerated aging periods all samples exhibited statistically color alteration; however, the varnished samples had lower color change for all periods.
2

Influência da adição de nanopartículas na estabilidade de cor, microdureza e resistência à flexão de resina específica para confecção de próteses oculares

Andreotti, Agda Marobo [UNESP] 31 January 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:46Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-01-31Bitstream added on 2015-03-03T12:07:03Z : No. of bitstreams: 1 000795011.pdf: 3623811 bytes, checksum: d8263b2bba7ed088e7be14e351d1311c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Uma alternativa segura para reabilitar pacientes com anoftalmia é a utilização de próteses oculares. O conhecimento das propriedades físicas e mecânicas da resina acrílica utilizada na confecção destas próteses é de suma importância. Nanopartículas vêm sendo adicionadas à cadeia polimérica das resinas com o objetivo de melhorar essas propriedades. Assim, o propósito desse estudo foi avaliar a influência da adição de nanopartículas na estabilidade de cor, microdureza e resistência à flexão da resina acrílica N1 específica para confecção da esclera artificial. Para isso, foram confeccionadas 300 amostras. As nanopartículas utilizadas foram Óxido de Zinco (ZnO), Dióxido de Titânio (TiO2) e Sulfato de Bário (BaSO4), nas concentrações de 1, 2 e 2,5%. As amostras foram distribuídas em 10 grupos (n=30) de acordo com o tipo e concentração de nanopartícula associada à resina acrílica N1: controle - sem nanopartícula (C), óxido de zinco 1% (ZnO 1%), óxido de zinco 2% (ZnO 2%), óxido de zinco 2,5% (ZnO 2,5%), dióxido de titânio 1% (TiO2 1%), dióxido de titânio 2% (TiO2 2%), dióxido de titânio 2,5% (TiO2 2,5%), sulfato de bário 1% (BaSO4 1%), sulfato de bário 2% (BaSO4 2%), sulfato de bário 2,5% (BaSO4 2,5%). Os ensaios de leitura de cor, microdureza e resistência à flexão foram realizados antes e após 1008 horas de envelhecimento acelerado. Os dados obtidos foram submetidos à análise estatística, utilizando-se os testes de nested ANOVA e teste de Tukey. Os resultados demonstraram que, comparando-se as diferentes nanopartículas, os grupos com TiO2 apresentaram melhor estabilidade de cor, para todas as concentrações. Em relação ao teste de microdureza, com exceção dos grupos C e com adição de óxido zinco, os valores de microdureza aumentaram após envelhecimento, sendo que, nas concentrações de 1 e 2%, os grupos com... / A safe, aesthetic and satisfactory alternative to rehab patients with anofthalmia is the use of ocular prosthesis. It is very important to know about the physical and mechanical properties of the acrylic resin used on this prosthesis production. Nanoparticles have been added to the acrylic resins polymeric chain in order to improve these properties. So, this study aims to assess the influence of nanoparticles addition on the color stability, microhardness, and flexural resistance of artificial sclera N1 acrylic resin. To this purpose, 300 samples were made. The nanoparticles used were Zinc Oxide (ZnO), Titanium Dioxide (TiO2) and Barium Sulfate (BaSO4), at the concentrations of 1, 2 and 2%. Samples were divided into 10 groups (n=30), according to the nanoparticle and concentration associated with the resin: control – without nanoparticle (C); zinc oxide 1% (ZnO 1%) ; zinc oxide 2% (ZnO 2%); zinc oxide 2,5% (ZnO 2,5%); titanium dioxide 1% (TiO2 1%); titanium dioxide 2% (TiO2 2%); titanium dioxide 2,5% (TiO2 2,5%); barium sulfate 1% (BaSO4 1%), barium sulfate 2% (BaSO4 2%); barium sulfate 2,5% (BaSO4 2,5%). The color stability, microhardness and flexural resistance tests were performed before and after 1008 hours of accelerated aging. Data were subjected to statistical analysis using nested ANOVA and Tukey test. The results showed that, comparing the different nanoparticles, the groups with TiO2 showed better color stability at all concentrations. Microhardness values increased after artificial aging, except for groups C and ZnO and groups with TiO2 at 1 and 2% showed the highest statistically significant values compared with the other nanoparticles. Regarding flexural strength, at initial period, there was statistically significant difference between control group and the other groups. By comparing the periods, the C group... / FAPESP: 12/02907-0
3

Protese ocular individualizada em resina acrílica com esfera oca

Oliveira, Simone Helena Gonçalves de [UNESP] 26 July 1995 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:23:47Z (GMT). No. of bitstreams: 0 Previous issue date: 1995-07-26. Added 1 bitstream(s) on 2015-12-10T14:28:08Z : No. of bitstreams: 1 000026551.pdf: 1739809 bytes, checksum: 96937536447eb6f4c94bc8e2631f4167 (MD5) / A técnica proposta visa conseguir uma diminuição de peso das próteses oculares individualizadas amplas de resina acrílica, com passos laboratoriais simplificados. Para isso utilizaram-se esferas ocas pré fabricadas de material plástico, que são incluídas dentro da esclera. Compararam-se os pesos médios de escleras maciças convencionais (5,30g) com os de escleras com esferas ocas pré-fabricadas de material plástico (3,91g), respectivamente. A redução de peso foi significante com intervalo de confiança de 95% pelo teste t de Student. Foi também executada a técnica, a título de ilustração, em pacientes do Ambulatório da Disciplina de Prótese Buco-Maxilo-Facial da Faculdade de Odontologia do Câmpus de São José dos Campos-Unesp, tendo cada paciente recebido uma prótese maciça e uma prótese com esfera oca pré-fabricada de material plástico. Concluiu-se que as próteses e as escleras que possuem no seu interior a esfera oca pré-fabricada de material plástico são mais leves que as escleras maciças e que a técnica é viável para cavidades anoftálmicas amplas e é praticada em poucas sessões / The technique proposed aims at reducing the weight of individualized ample ocular prostheses using acrylic resins as well as simplifying laboratory procedure. For that, prefabricated hollow spheres made of plastic material, were inserted in the sclera. The average weights of the solid conventional sclera (5.30g) and those of the respective prefabricated plastic ones (3.91g) were compared. The weight reduction was significative with a confidence interval of 95% by the Student t test. ln addition, for illustration purpose, the technique was applied to patients in the ward of the Maxillofacial Prostheses Dicipline of the Dentistry School in the Campus of São José dos Campos - UNESP, having each patient received a solid prosthesis and a hollow prefabricated one made of plastic material. It has been concluded that the prostheses material spheres were inserted are lighter than the ones which received solid spheres; furthermore, thr technique is viable for ample anophtalmic cavities and requires few sessions
4

Análise in vitro da proliferação celular e produção de mediadores inflamatórios por células da conjuntiva estimuladas por materiais utilizados na confecção de próteses oculares

Silva, Emily Vivianne Freitas da [UNESP] 07 April 2015 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:25:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-04-07. Added 1 bitstream(s) on 2015-09-17T15:46:23Z : No. of bitstreams: 1 000847893.pdf: 1252256 bytes, checksum: 1fd716895e2784e4359da8659fd760e0 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A prótese ocular é utilizada para a reabilitação estética e funcional da ausência ocular. O conhecimento da sua biocompatibilidade é importante para a utilização sem reações danosas aos usuários. O objetivo neste estudo foi avaliar a citotoxicidade de materiais utilizados na confecção de próteses oculares, por meio da análise da proliferação celular e da produção de citocinas pró-inflamatórias e de proteínas de matriz extracelular por células da conjuntiva humana. Inicialmente, foi analisada a influência de diferentes períodos de formação e de exposição dos extratos de resina acrílica branca (N1), termopolimerizada em água aquecida, sobre culturas de células da conjuntiva. Foram confeccionados 24 corpos de prova em resina, sendo 12 para cada período de exposição de células da conjuntiva aos extratos da resina testada (24 e 72 horas). Após a formação dos extratos por 24, 48 e 72 horas de imersão em meio de cultura e, 24 horas em água seguido de 24 horas de imersão em meio, os ensaios propostos foram realizados (n=3). Em seguida, foi avaliado o efeito citotóxico de diferentes métodos de polimerização de resina acrílica N1 em células da conjuntiva. Foram confeccionados 9 corpos de prova em resina (n=3), termopolimerizados em água aquecida, por energia de microondas ou ativados quimicamente, utilizados para a formação dos extratos dessas resinas. Os extratos foram obtidos após 72 horas de imersão dos corpos de prova em meio de cultura e, então, expostos às células da conjuntiva por 72 horas para a realização dos ensaios propostos. Adicionalmente, foi analisada a influência da presença do pigmento acrílico na confecção da prótese de resina acrílica N1, termopolimerizada em água aquecida... / Ocular prosthesis is a treatment option for esthetical and functional rehabilitation of ocular absence. The knowledge of ocular prosthesis material's biocompatibility is important to ensure a safe use in patients. The aim of this study was to evaluate the cytotoxic effect of ocular prosthesis materials, through the analysis of the cell proliferation, and the production of proinflammatory cytokines and extracellular matrix proteins by a human conjunctival cell line. Initially, the influence of different preparation and exposition periods of eluates from heat-polymerized ocular prosthesis N1 color acrylic resin in human conjunctival cell line was evaluated. A total of 24 acrylic resin samples were manufactured and divided into 2 groups, according to the eluate exposition period to conjunctival cell line (24 and 72 hours). Eluates corresponding to 24, 48 and 72 hours of resin sample immersion in medium and, 24 hours of resin sample immersion in water followed by 24 hours of immersion in medium, were prepared (n=3) for the proposed tests. Then, the cytotoxic effect of different polymerization methods of ocular prosthesis N1 color acrylic resin was analyzed. A total of 9 acrylic resin samples were manufactured (n=3), according to the polymerization method: heat-polymerization in water bath, polymerization by microwave energy and auto-polymerization. Eluates corresponding to 72 hours of resin sample immersion in medium were prepared for proposed tests and exposed to conjunctival cell line for 72 hours. Additionally, the influence of pigment incorporation on the cytotoxicity of heat-polymerized ocular prosthesis N1 color acrylic resin was evaluated...
5

Influência da desinfecção química e do tempo de armazenagem sobre as propriedades físicas das próteses oculares

Moreno, Amália [UNESP] 04 February 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-02-04Bitstream added on 2014-06-13T20:58:50Z : No. of bitstreams: 1 moreno_a_me_araca.pdf: 1094331 bytes, checksum: 23ef0f4dabc4bc9f560778bae7c35338 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / As próteses oculares são responsáveis pela recuperação da estética e auto-estima do usuário. Assim, os materiais utilizados na confecção de prótese ocular devem possuir propriedades específicas para sua indicação e durabilidade. Desse modo, é importante avaliar o comportamento destes materiais quando influenciados por diversas soluções desinfetantes. Este estudo teve como objetivo avaliar a microdureza, rugosidade superficial e alteração de cor de próteses oculares sobre a influência da desinfecção química e armazenagem. Foram confeccionadas 50 amostras simulando próteses oculares contendo duas resinas acrílicas (N1 e incolor), distribuídas em cinco grupos de acordo com o desinfetante utilizado: sabão neutro (I), opti-free (II), efferdent (III), hipoclorito a 1% (IV) e clorexidina a 4% (V). As amostras foram armazenadas por 120 dias, sendo desinfetadas durante este período. As leituras de microdureza, rugosidade e cor das amostras foram realizadas em um período inicial (B) e após 60 (T1) e 120 (T2) dias de armazenagem com desinfecção. A microdureza foi mensurada por meio de um microdurômetro, e a rugosidade determinada por um rugosímetro. A leitura de cor foi realizada por meio da espectrofotometria de reflexão, usando o sistema CIE L*a*b*. A alteração de cor (ΔE) foi calculada para os períodos entre T1 e B (T1B), e T2 e B (T2B). Pelos resultados obtidos a resina N1 para esclera apresentou menor microdureza estatisticamente significante, comparada a resina incolor (P<0,05). A maior alteração dos valores de microdureza e rugosidade foi obtida para os grupos IV e V. Ambos os períodos de desinfecção e armazenagem produziram alterações significativas (P<0,05) nas amostras com diminuição dos valores de... / Ocular prostheses are responsible to restore not only patient’s aesthetic but also its self-esteem. The materials used to fabricate the ocular prostheses should present specific properties regarding its indication and durability. Therefore, it is important to investigate the physical behavior of such materials when subjected to different disinfectant solutions. This study evaluated the microhardness, surface roughness and color stability of ocular prostheses under the influence of different chemical disinfectant solutions and storage. A total of 50 samples simulating an ocular prosthesis containing two acrylic resins (N1 and colorless) were fabricated. They were divided into five groups as a function of disinfectant solution: neutral soap (I), opti-free (II), efferdent (III), 1% hypochlorite (IV) and 4% chlorhexidine (V). Samples were storage during 120 days, and they were disinfected throughout the period. Microhardness, roughness and color measurements were performed at baseline (B), after 60 (T1) and 120 (T2) days of storage with disinfection. The microharness and the roughness measurements were evaluated using a microdurometer and a roughness meter, respectively. Samples colors were measured with spectrophotometer using CIE L*a*b* system. Color differences (ΔE*) were calculated for periods between T1 and B (T1B), and T2 and B (T2B). The N1 acrylic resin exhibited statistically lower microhardness when compared to the colorless acrylic resin (P<0.05). The highest microhardness and roughness alterations were observed for groups IV and V. Both disinfection and storage periods statistically reduced the microhadness values and increased the roughness values of the samples (P<0.05). Color alteration was... (Complete abstract click electronic access below)
6

Avaliação da integração de implantes de silicone com superfícies lisa, texturizada e de poliuretano em cavidades anoftálmicas evisceradas de coelhos

Abreu, Cristiano Ricardo de [UNESP] 26 May 2014 (has links) (PDF)
Made available in DSpace on 2015-05-14T16:53:15Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-05-26Bitstream added on 2015-05-14T16:59:09Z : No. of bitstreams: 1 000816204.pdf: 522472 bytes, checksum: 25779cbe8f027d47edb97dfc753e8174 (MD5) / Objetivo: Visando acrescentar novos conceitos na área da reconstrução da cavidade anoftálmica e utilizando conhecimento adquirido na Cirurgia Plástica, o presente estudo foi desenvolvido com o objetivo de avaliar a integração dos implantes hemi-esféricos de silicone em gel coesivo com três diferentes tipos de superfície (lisa, texturizada e de poliuretano), empregados para devolução do volume perdido de cavidades evisceradas de coelhos. Método: Foram utilizados 45 coelhos albinos, machos, espécie Orictolagus cuniculus, que tiveram o olho direito eviscerado, sendo feita a colocação de implantes hemi-esféricos de silicone em gel coesivo na cavidade orbitária. Os implantes diferiram entre si pelos revestimentos, que foram de três tipos: liso (Grupo (GI)), texturizado (GII) ou de poliuretano (GIII). Cada grupo foi constituído por 15 animais, sendo que 5 animais de cada grupo foram sacrificados 7 (M7), 30 (M30) ou 90 (M90) dias após a cirurgia de evisceração e colocação do implante. Foram realizadas avaliações clínica, laboratorial (exame de creatinina sérica e de 2,4 toluenodiamina - TDA), tomográfica usando o programa OsiriX® (posição e área do implante), histológica e morfométrica (medida da espessura da pseudocápsula e da celularidade). Os resultados obtidos foram submetidos à avaliação estatística comparando-se os grupos com diferentes tipos de revestimentos dos implantes, nos três momentos de sacrifício. Resultados: Houve boa evolução em todos os grupos experimentais, não se observando extrusão ou processos infecciosos ao longo do período experimental. A avaliação histológica mostrou que os implantes de superfície lisa (GI), texturizada (GII) ou de poliuretano (GIII) tiveram boa integração tecidual, com maior reação inflamatória e espessura da pseudocápsula nos implantes de GIII. No exame tomográfico, os implantes de GI mudaram mais de posição e foram evidenciadas deformidades nos ... / Purpose: In order to add new concepts in the area of the anophthalmic socket reconstruction and using knowledge acquired in Plastic Surgery, this study was developed to evaluate the integration of hemi-spherical cohesive gel silicone implants coated by three different surfaces (smooth, textured and polyurethane) used to replace the missed volume in eviscerated cavities of rabbits. Methods: Forty-five albino male rabbits of the specie Oryctolagus cuniculus had their right eye eviscerated and hemi-spherical cohesive gel silicone implants were inserted in the orbital socket to replace volume. The implants were coated by three different types of surfaces: smooth (Group (IG)), textured (GII) or polyurethane (GIII). Each group was composed by 15 animals and five of them in each group were sacrificed seven (M7), 30 (M30) and 90 (M90) days after evisceration surgery and implant placement. Clinical and laboratorial assessments (creatinine test and 2,4 toluene diamine- TDA), histologic and morphometric exam (measurement of the thickness of pseudocapsule and cellularity) and tomographic (CT scan) evaluation using the OsiriX program (position and area of the implant) were performed. The results were analyzed statistically comparing groups that differ by the coating of implants in the three moments of sacrifice. Results: There was good evolution in all experimental groups and extrusion or infectious processes was not observed throughout the experimental period. Histological evaluation showed that implants with a smooth (GI), textured (GII) or polyurethane surface (GIII) had good tissue integration and GIII implants showed greater inflammatory reaction and thickness of the pseudocapsule. On CT scan, the GI implants changed over position and deformities were observed in the GIII implants. Using OsiriX® program was possible to evaluate the area of the implants. The 2,4 TDA was not found in any of the experimental groups. Conclusion: Cohesive gel ...
7

Avaliação da adesão de Staphylococcus spp. em resina acrílica específica para prótese ocular e alteração de cor de botões de íris artificiais, variando a cor e as técnicas de obtenção, ambos após desinfecção química

Moreno, Amália [UNESP] 13 June 2014 (has links) (PDF)
Made available in DSpace on 2015-05-14T16:53:34Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-06-13Bitstream added on 2015-05-14T16:58:38Z : No. of bitstreams: 1 000821328.pdf: 1693611 bytes, checksum: 2f11602ee222c6ad0cb896f0664f78e8 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / As próteses oculares são responsáveis pela recuperação da estética e auto-estima do usuário. Assim, os materiais utilizados na confecção de prótese ocular devem possuir propriedades específicas para sua indicação e durabilidade principalmente aos procedimentos de desinfecção pelo paciente. Desse modo, este estudo teve como objetivo verificar a efetividade de diferentes soluções desinfetantes na remoção de biofilme de duas espécies de Staphylococcus spp., desenvolvidas na superfície de resina acrílica específica para prótese ocular e avaliar a alteração de cor de botões de íris artificiais confeccionadas por diferentes técnicas antes e após a polimerização e quando influenciadas pela desinfecção química. Para o teste de microbiologia, 396 amostras em resina acrílica para prótese ocular N1 foram confeccionadas (1,0 cm em diâmetro e 0,3 cm em espessura), sendo metade dessas amostras para formação de biofilme de S. epidermidis e a outra metade para formação de biofilme de S. aureus, ambos na superfície da amostra. Para cada cepa bacterina, 66 amostras foram submetidas a formação de biofilme em sua superfície durante três diferentes tempos: inicial (24h), intermediário (48h) e maduro (72h). Em seguida as amostras foram distribuídas aleatoriamente (unidade amostral n=6) para um dos tratamentos desinfetantes: água destilada durante 10, 15, 30 min e 6 h (controle-CTL); sabão neutro (NES) durante 30 min; Opti-Free durante 30 min e 6 h; Efferdent (EFF) durante 15 min; e gluconato de clorexidina (0,5%; 2% e 4%) (CHX) durante 10 min. Após o tratamento desinfetante, as amostras acrílicas foram imediatamente agitadas para desprendimento do biofilme. A contagem de colônias foi verificada por análise do número de UFC/mL. Para a análise de alteração de cor 300 amostras simulando próteses oculares foram confeccionadas, sendo metade... / Considering that ocular prostheses restore esthetics and patient’s self-esteem, the materials used for prosthesis fabrication should present appropriate properties regarding indication and reliability after the disinfection procedures. So, the aim of this study was to assess the effectiveness of different disinfectant solutions against two species of Staphylococcus spp. cultured on ocular prosthesis acrylic resin. In addition, the chromatic change of artificial iris buttons fabricated with different techniques was also evaluated before and after polymerization and disinfection. For the microbiology tests 396 acrylic specimens were fabricated (1.0 cm in diameter and 0.3 cm in thickness). Half of the samples were made for biofilm formation of S. epidermidis and half were made for biofilm formation of S. aureus, both on the sample surface. For each strain, 66 samples were underwent to biofilm formation on the liner surface for three different points: initial (24h), intermediate (48h) and mature (72h). Afterwards the specimens were randomly assigned (unit sample n = 6) to one of disinfectant treatments: distilled water for 10, 15, 30 min and 6 h (control-CTL); treated with neutral soap (NES) for 30 min; treated with Opti-Free (OPT) for 30 min and 6 h; treated with Efferdent (EFF) for 15 min; and treated with (0.5%, 2% and 4%) chlorhexidine gluconate (CHX) for 10 min. After the treatments, the specimens were vortexed to disrupt the biofilm, and residual cells were counted (cell/mL). For the color meansurations a total of 300 samples simulating ocular prosthesis were fabricated. Half of the samples were made with blue artificial irises, and half were made with brown artificial irises. For each color, 50 samples were fabricated according to one of the following techniques: PE - conventional technique, CA - prefabricated... / FAPESP: 11/05864-8

Page generated in 0.0541 seconds