Spelling suggestions: "subject:"insite wastewater 1treatment"" "subject:"insite wastewater entreatment""
1 |
BOD5 removal in subsurface flow constructed wetlandsMelton, Rebecca Hobbs 29 August 2005 (has links)
The frequency of on-site systems for treatment of domestic wastewater is
increasing with new residential development in both rural and low-density suburban
areas. Subsurface flow constructed wetlands (SFCW) have emerged as a viable option
to achieve advanced or secondary treatment of domestic wastewater. The pollutant
removal efficiency in SFCW depends on design parameters. Many of these factors have
been investigated while others such as aspect ratio, design of water inlet structure and
method of dosing the wetland have yet to be fully examined. This study examined the
effect of aspect ratio and header design on BOD5 removal efficiency as well as the
impact of flow rate on flow distribution in a SFCW. An aspect ratio of 4:1 achieved
10% greater removal of organic matter than a 1:1 ratio. Tracer studies demonstrated that
wetlands loaded at a constant rate of 3.8 L/min and 7.6 L/min experienced preferential
flow. In addition, tracer studies showed wetlands with leaching chambers as headers
failed to achieve equal flow distribution. An improvement in effluent water quality was
achieved by replacing the leaching chamber for a perforated manifold as the inlet
structure. This study demonstrated the importance of the careful selection of aspect ratio
and means by which water is introduced to the wetland in the design of SFCW.
|
2 |
Sustainable phosphorus removal in onsite wastewater treatmentEveborn, David January 2013 (has links)
Aquatic eutrophication is a serious environmental problem that occurs all over the world. To protect surface waters (in particular the Baltic Sea), the regulatory pressure on onsite wastewater treatment (OWT) systems have increased in Sweden. Stringent requirements have led to uncertainties regarding the capability of conventional treatment techniques (soil treatment systems (STS)) to remove phosphorus (P), but they have also stimulated the development and introduction of enhanced P treatment techniques. In this thesis the accumulation and mobility of P as well as the chemical P removal mechanisms were studied in soils and reactive filter media. This knowledge was then used in environmental systems analysis. A model based on life cycle assessment (LCA) methodology was developed to evaluate the overall environmental performance of conventional and enhanced P treatment systems under various local conditions. The P accumulation in the studied STS varied (320-870 g m-3) and the accumulated P was rather mobile in some soils. Phosphorus compounds were identified in alkaline reactive filter media (calcium phosphates predominated) by means of X-ray Absorption Near Edge Structure (XANES). In sandy soils from STS aluminium was found to be a key element for P removal, as evidenced by a strong relationship between oxalate-extractable P and Al. The LCA studies indicated that enhanced P treatment systems may be beneficial from an eutrophication and P recycling perspective but causes increased impacts in terms of global warming and acidification. Despite the drawbacks, enhanced P treatment techniques should be considered suitable substitutes to surface water discharge STS under most conditions. This is because the latter systems have such a strong eutrophication impact. On the other hand, under appropriate conditions, STS with groundwater discharge may be advantageous. These systems generally caused low environmental impacts except for the dispersion of P resources. / <p>QC 20130419</p>
|
3 |
SLUDGE ACCUMULATION AND CHARACTERIZATION IN DECENTRALIZED COMMUNITY WASTEWATER TREATMENT SYSTEMS WITH PRIMARY CLARIFIER TANKS AT EACH RESIDENCELOSSING, HEATHER 29 April 2009 (has links)
Sludge accumulation, treatment and disposal can represent a high percentage of the operating cost for a wastewater system. This is especially important for small-scale and onsite wastewater treatment systems, where sludge removal can be one of the few operating costs of the system. In 2000, as a result of a large number of septic system failures, the community of Wardsville installed a Clearford Industries Inc. Small Bore Sewer™ (SBS™) system which included two-chamber 3600 L tanks located on the properties of individual homes. The tanks were collectively attached to a small bore piping system to deliver the effluent from the tanks to a small community wastewater treatment system.
During the summer of 2007, a field study was initiated with a community survey, followed by a review of candidate sites, leading to the selection of 29 sites for site investigation and sampling. Sampling involved the collection of samples for sludge characterization along with the measurements of the height of solids (scum and sludge) within the tank. The data were analyzed to determine the factors having a statistically significant impact on solids accumulation rates within each of the two chambers of the tank. Household water usage was found to be the variable having the strongest association with sludge and scum accumulation, and models were estimated relating solids accumulation to water usage in order predict pump out frequency. A second field sampling program was conducted in Wardsville during April 2008, involving only the first chamber of 13 primary clarifier tanks.
Overall contributions have been made in understanding and quantifying solids accumulation rates and sludge characterization in onsite primary clarifier tanks. As well, the information gained from the analysis of the data collected provides a meaningful insight into the factors influencing solids accumulation within individual residential primary clarifier tanks, and points to future research directions for understanding the factors influencing solids accumulation. / Thesis (Master, Civil Engineering) -- Queen's University, 2009-04-25 15:34:46.243
|
4 |
SLUDGE ACCUMULATION AND CHARACTERIZATION IN DECENTRALIZED COMMUNITY WASTEWATER TREATMENT SYSTEMS WITH PRIMARY CLARIFIER TANKS AT EACH RESIDENCELOSSING, HEATHER 29 April 2009 (has links)
Sludge accumulation, treatment and disposal can represent a high percentage of the operating cost for a wastewater system. This is especially important for small-scale and onsite wastewater treatment systems, where sludge removal can be one of the few operating costs of the system. In 2000, as a result of a large number of septic system failures, the community of Wardsville installed a Clearford Industries Inc. Small Bore Sewer™ (SBS™) system which included two-chamber 3600 L tanks located on the properties of individual homes. The tanks were collectively attached to a small bore piping system to deliver the effluent from the tanks to a small community wastewater treatment system.
During the summer of 2007, a field study was initiated with a community survey, followed by a review of candidate sites, leading to the selection of 29 sites for site investigation and sampling. Sampling involved the collection of samples for sludge characterization along with the measurements of the height of solids (scum and sludge) within the tank. The data were analyzed to determine the factors having a statistically significant impact on solids accumulation rates within each of the two chambers of the tank. Household water usage was found to be the variable having the strongest association with sludge and scum accumulation, and models were estimated relating solids accumulation to water usage in order predict pump out frequency. A second field sampling program was conducted in Wardsville during April 2008, involving only the first chamber of 13 primary clarifier tanks.
Overall contributions have been made in understanding and quantifying solids accumulation rates and sludge characterization in onsite primary clarifier tanks. As well, the information gained from the analysis of the data collected provides a meaningful insight into the factors influencing solids accumulation within individual residential primary clarifier tanks, and points to future research directions for understanding the factors influencing solids accumulation. / Thesis (Master, Civil Engineering) -- Queen's University, 2009-04-25 15:34:46.243
|
5 |
Modeling Onsite Wastewater Treatment Systems in the Dickinson Bayou WatershedForbis-Stokes, Aaron 2012 August 1900 (has links)
Onsite wastewater treatment systems (OWTSs) are a commonly used means of wastewater treatment in the Dickinson Bayou watershed which is located between Houston and Galveston. The Dickinson Bayou is classified as "impaired" by the Texas Commission on Environmental Quality due to high levels of bacteria, specifically E. coli. Failing OWTSs within the bayou's watershed are possible sources for the impairment of the bayou. Conventional OWTSs, comprised of a septic tank and a soil absorption field, rely heavily on soil treatment of effluent. The type of soils is a significant factor in treatment capabilities. In the Dickinson Bayou watershed, soils are primarily composed of clays, which are known to be problematic for conventional systems as they restrict water flow and create perched water tables. These perched water tables may contribute to surface runoff during rainfall events. The HYDRUS modeling software for water and solute flow through variably saturated media was used to simulate OWTSs in the Dickinson Bayou watershed. HYDRUS was used to simulate conventional septic systems with soil absorption fields, aerobic treatment units (ATUs) with spray dispersal systems, and mound systems. Results found that the simulated conventional systems fail due to high water tables and clay soils. However, system failure in the watershed remains uncertain due to lack of field data for validation. The alternative systems mitigate these issues, but ATUs can lead to higher contamination levels without proper maintenance. Therefore, mound systems are the suggested alternative for OWTSs in the watershed.
|
6 |
The Fate of Fecal Indicator Bacteria in Passive Nitrogen Reduction SystemsHenderson, Michelle B. 14 July 2017 (has links)
The sustainability of water resources is an international and national concern. With increased human activity, water distribution on a global, regional, and local scale has been negatively impacted. Managing water resources also includes managing wastewater. A promising solution to the issues of water scarcity and distribution in the environment is the reuse of wastewater. Wastewater is produced from various sources (domestic, industrial, and commercial); however, if this water is able to be reused closer to the source of generation it could positively impact water distribution. In the United States, approximately 25% of domestic wastewater is treated in onsite wastewater treatment systems OWTS (mainly septic tanks and drainfields). However, septic systems are not efficient at removing nitrogen and pathogens, making them a risk to public health and the environment.
In recent years, advanced onsite wastewater treatment systems have been developed to reduce contaminants into the environment. These systems are effective at removing contaminants but often require many mechanical parts and have high energy requirements. These additional components require homeowners to perform more maintenance on advanced OWTS than conventional systems or pay for maintenance to be performed. Passive Nitrogen Reduction Systems (PNRS) are being developed that provide high levels of nutrient removal while keeping maintenance requirements and costs low for the homeowner. (PNRS) use two-stage packed bed bioreactors to remove nitrogen from wastewater via nitrification (Stage I) and denitrification (Stage II). Our laboratory has developed a two-stage bench scale PNRS that uses ion exchange (IX) materials, clinoptilolite and scrap tire chips, to enhance the removal of nitrogen from wastewater by buffering transient loads to the biological processes. Pathogens can be present in domestic wastewater and if untreated can be released to groundwater and open water bodies endangering the health of the public. PNRS have the potential to reduce pathogenic microorganism released into the environment, however; the reduction of pathogens in PNRS that include IX media had not previously been studied.
In this research, E. coli was used as a fecal indicator bacteria (FIB) because of its simplicity and national and worldwide acceptance. In our study, the performance of a PNRS with and without IX media was evaluated. Hourly studies were performed to determine the removal efficiency of E. coli from the system under varying hydraulic loading rates. Biofilm detachment experiments were conducted to measure E. coli adsorption and growth patterns within the column reactors. Batch adsorption experiments were completed to determine the effect of different types of media with and without IX material on E. coli growth over extended time periods.
E. coli enumeration data from the hourly experiments demonstrated that there was a 0.84 log reduction of E. coli throughout the PNRS from the septic tank effluent to the final effluent released from the system. The evening and afternoon periods showed a higher reduction of E. coli compared with the morning period. Removal efficiencies were greater in the first stage of treatment (nitrification) as compared to the second stage treatment (denitrification). However, these variances did not result in significant differences in overall E. coli removal efficiency. Adsorbed E. coli were evenly distributed in the column containing IX media, while a decrease in adsorbed E. coli with depth was observed in the column without IX media. Batch adsorption studies revealed that when E. coli are present in wastewater solution with media, E. coli are initially adsorbed but can grow in the system after 6-12 hours. This growth indicates that other FIB should also be used to determine the fate of pathogens in PNRS. Based on all E. coli enumeration experiments, the PNRS developed reduce E. coli by almost 85%; however, this reduction is not adequate to meet onsite water reclamation regulations. Further studies are needed to develop tertiary treatment for pathogen reduction and wastewater reuse.
|
7 |
Optimizing resources – studying ways to recycling phosphorus from onsite wastewater treatment plants.Sammeli, Maria January 2015 (has links)
Eutrophication of the Baltic Sea has been an issue for decades and the pollution constantly continues with oxygen deficient bottoms and a damaged marine life as a result. One of the main causes of eutrophication are elevated levels of the nutrient phosphorus. Phosphorus leaks to the sea from various human activities such as agriculture, animal farming and sewage. In Sweden, the onsite wastewater treatment systems are a big problem since they load the Baltic Sea with nearly as much phosphorus as all Swedish municipal wastewater treatment plants. The need for a reduced impact on the Baltic Sea is major and the individual wastewater treatment systems must therefore be looked over. While phosphorus is a contributing factor to eutrophication, it is one of the most important nutrients for all life. Phosphorus builds up our DNA, helps transport of various substances in and out of our cells and provides energy to the cell's processes. We would simply not be able to survive without phosphorus. We ingest phosphorus through the food we eat, which in turn is dependent on fertilizers containing phosphorus. Phosphorus is mined from phosphate ore and the majority of it is used to produce fertilizers. Unfortunately, phosphate ore is not a finite resource and in the last few years it has been realized that the economically extractable phosphorus is a dwindling resource. To be able to produce food for the world's growing population, we need to find ways to recycle phosphorus. In individual drainage systems there is a large potential to catch up phosphorus and then reuse it on agricultural land. This thesis deals with the problems of onsite wastewater treatment systems and suggests measures to improve their status. Ways to recycle phosphorus in combination with having a well-functioning drainage is being investigated and difficulties about the regulations are being discussed. To recover phosphorus and at the same time reduce the burden on the environment should be seen as an incredibly important action, since our sea’s health is acute but lack of the nutrient could have devastating consequences.
|
8 |
Onsite Remediation of Pharmaceuticals and Personal Care Products in Domestic Wastewater using Alternative Systems Including Constructed WetlandsGreenberg, Chloe Frances 15 March 2017 (has links)
Pharmaceuticals, personal care products (PPCPs) and other trace organic contaminants (TOrCs) encompass a diverse group of chemicals that are not currently monitored or regulated in US drinking water or wastewater. Researchers have found low levels of TOrCs in aquatic and terrestrial environments all over the globe, and observed negative effects on impacted biota. The primary source of TOrCs in the environment is domestic wastewater discharges. Centralized wastewater treatment plants present greater risks on a global scale, but on a local scale, onsite treatment systems may have more potent impacts on resources that are invaluable to residents, including groundwater, surface waters, and soils.
The objective of this thesis is to identify and characterize promising treatment technologies for onsite TOrC remediation. Receptors who could be impacted by TOrC discharges are assessed, and applications that may require alternative treatment are identified. The best treatment technologies are recognized as those that protect sensitive environmental receptors, provide permanent removal pathways for as many TOrCs as possible, and are not prohibitively expensive to install or maintain. Findings from a pilot study show increased removal of conventional pollutants and TOrCs in an aerobic treatment unit (ATU), two types of biofilter, and a hybrid constructed wetland, all relative to septic tank effluent. The constructed wetland achieved the highest nutrient removals with TN concentrations below 10 mg/L throughout the study. A system with an ATU and peat biofilters achieved the highest removals of persistent pharmaceuticals carbamazepine and lamotrigine (>85% and >95%, respectively). / Master of Science / Trace organic contaminants (TOrCs) are chemicals found in pharmaceuticals, laundry detergents, shampoo, flame retardants, food preservatives, and many other products used in a typical home, which are not currently monitored or regulated in US drinking water or wastewater. Researchers have found low levels of TOrCs in waters and soils all over the globe, and observed negative effects on the plants and animals that live in those environments. The primary source of TOrCs in the environment is treated wastewater from centralized wastewater treatment plants, which is usually released to rivers, lakes, and other surface waters. People in rural communities also have TOrCs in their wastewater, which is normally treated using a septic system. Water released in the septic field can add TOrCs to septic field soils, groundwater sources, or nearby surface water sources, and from there these chemicals have the potential to impact human health, soil fertility, livestock health, or fish and other living things in surface waters.
The objective of this thesis is to identify and characterize promising treatment technologies that would prevent or limit TOrC impacts to these important resources, which are called “receptors.” Receptors who could be impacted by TOrC discharges are assessed, and the situations in which these treatment technologies would be necessary are identified. The best treatment technologies are recognized as those that protect sensitive environmental receptors, remove as many TOrCs as possible, and are affordable to install or maintain. An experiment was designed to compare the performance of three different technologies that could remove TOrCs from septic tank effluent, including a peat filter and a constructed wetland. The constructed wetland removed the most nitrogen (total nitrogen <10 mg/L throughout the study), and a system with a peat filter removed the greatest amounts of persistent pharmaceuticals carbamazepine and lamotrigine (averaging >85% and >95%, respectively).
|
9 |
Effect of design and dosing regime on the treatment performance of vertical flow constructed wetlandsOlsson, Linda January 2011 (has links)
Vertical flow constructed wetlands (VF CWs) are becoming increasingly popular for onsite wastewater treatment due to their high oxygen transfer capacity and high nitrification rates. However, there are still some question marks regarding (1) how the treatment performance of VF CWs is affected by design and operational parameters, and (2) the treatment processes happening inside the wetland bed as the wastewater percolates through. In this study, we investigated the effects of filter media (coarse sand or fine gravel), dosing regime (hourly with 4 mm or bi-hourly with 8 mm) and plant presence (with or without Phragmites australis) on the treatment performance and concentration depth profiles of pollutant removal in six pilot-scale VF CWs treating primary treated domestic wastewater. Grab samples of wastewater were collected every 2-3 weeks during 5 months and analyzed for organic matter, suspended solids, nitrogen and E. coli. We found that sand beds performed better than gravel beds for removal of all pollutants except total nitrogen, although for long term operation gravel may be less susceptible to clogging. The overall treatment performance was not affected by different dosing regimes, but the concentration depth profiles showed that smaller and more frequent doses led to more pollutant removal in the upper part of the beds. The presence of plants was moderately important for the removal of ammonium, but had no effect on other pollutants.
|
10 |
Evaluation d'un système de traitement à base de biomasse végétale pour le traitement décentralisé des eaux usées : du pilote à l'échelle industrielle / Evaluation of a lignocellulosic biomass-based processing system for decentralized wastewater treatment : from pilot plant to full-scaleVillalobos Garcia, Jésus 15 June 2018 (has links)
L'assainissement a de tout temps été une préoccupation majeure pour des questions d'hygiène et de santé publique. Une installation d'assainissement non collectif (ANC) assure la collecte, le transport, le traitement et l'évacuation des eaux usées domestiques. En France, l’ANC représente 20 % des installations de traitement des eaux usées domestiques. Cela concerne une population de 12 millions d'habitants, soit environ cinq millions d'installations en zones rurales. Parmi les technologies utilisées dans l’ANC, les systèmes de filtration biologique utilisant un milieu filtrant sont souvent mis en oeuvre. Le traitement des eaux usées (élimination des matières en suspension et de la matière organique) est effectué par les actions conjointes de filtration, et de biodégradation par des bactéries se développant au sein du milieu filtrant. Historiquement, des matériaux comme le sable et la tourbe sont les plus utilisés, et plus récemment des milieux à base de copeaux de coco venus remplacer la tourbe dont l’extraction est interdite, sont en développement croissant. Cependant, l’empreinte carbone produite par l'importation depuis l'étranger de matériaux tels que ce dernier est très importante. Dès lors l’utilisation de sousproduits agro-industriels locaux pourrait la diminuer et rendre l’utilisation de ces nouveaux milieux filtrants plus compatible avec des critères environnementaux. Le premier objectif de cette thèse est de déterminer le degré de fiabilité en conditions réelles d’un milieu filtrant innovant d’origine végétale ayant fait ses preuves en conditions de laboratoire. L’étude est basée sur la mise en parallèle de résultats obtenus en laboratoire et sur le terrain. Au laboratoire, une approche hydraulique a permis de caractériser le fonctionnement du lit filtrant. Sur le terrain, l’évaluation d’un filtre compact qui fonctionne de façon continue depuis plus de quatre ans et de cinq autres installations a été réalisée. Pour l’ensemble des installations, le milieu filtrant testé permet d’obtenir une qualité des eaux rejetées en accord avec la règlementation en vigueur. Les pourcentages moyens de réduction estimés de la DCO, de la DBO5 et des MES sont respectivement de plus de 79 %, 98 % et 88 %, confirmant ainsi la forte dégradation de la matière carbonée et de la pollution particulaire. Le second objectif de cette thèse consiste à établir un jeu de paramètres physicochimiques permettant de guider le choix de nouveaux matériaux potentiellement utilisables en ANC. Pour ce faire, la caractérisation des paramètres physicochimiques clés de nouveaux matériaux et des paramètres hydrauliques des lits filtrants correspondants a été effectuée. Une analyse statistique a permis d’étudier les corrélations entre ces paramètres et les performances épuratoires des matériaux. Au final, une méthodologie de sélection a été proposée. / Sanitation has always been a major concern for hygiene and public health issues. An on-site sewage facility (OSSF) ensures the collection, transportation, treatment and disposal of domestic wastewater. In France, the OSSF represents 20% of domestic wastewater treatment facilities. This represents a population of 12 million or about five million rural settlements. Among the technologies used in the OSSF, biological filtration systems using a filter media are often implemented. The treatment of wastewater (removal of suspended solids and organic matter) is carried out by the joint actions of filtration, and biodegradation by bacteria developing within the filter media. Historically, materials such as sand and peat are the most used. More recently coconut-based media to replace peat, the extraction of which is prohibited, are in increasing development. However, the carbon footprint of foreign imports of materials such as coconut is very important. Therefore, the use of local agro-industrial by-products could reduce the carbon footprint and make the use of these new filter media more compatible with environmental criteria. The first objective of this PhD thesis is to determine the degree of reliability under real conditions of an innovative filtering medium of lignocellulosic origin that has been proven successful in laboratory conditions. The study is based on the comparison of results obtained in the laboratory and in the field. In the laboratory, a hydraulic approach allowed the characterisation of the filter bed operation. In the field, the evaluation of a compact filter that has been running continuously for more than four years and five other installations has been completed. For all installations, the filter media tested allowed a quality of the discharged water in accordance with the current regulations. The estimated average reduction percentages of COD, BOD5 and TSS, are respectively over 79%, 98% and 88%, thus confirming the important degradation of the organic matter and particulate pollution. The second objective of this PhD thesis is to establish a set of physicochemical parameters to guide the choice of new materials potentially usable in OSSF. To do this, the characterisation of the key physicochemical parameters of new materials and the hydraulic parameters of the corresponding filter beds were carried out. Statistical analysis made it possible to study the correlations between these parameters and the purification performances of the materials. In the end, a selection methodology has been proposed.
|
Page generated in 0.0993 seconds