• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Load Adapted Solar Thermal Combisystems - Optical Analysis and Systems Optimization

Nordlander, Svante January 2004 (has links)
In a northern European climate a typical solar combisystem for a single family house normally saves between 10 and 30 % of the auxiliary energy needed for space heating and domestic water heating. It is considered uneconomical to dimension systems for higher energy savings. Overheating problems may also occur. One way of avoiding these problems is to use a collector that is designed so that it has a low optical efficiency in summer, when the solar elevation is high and the load is small, and a high optical efficiency in early spring and late fall when the solar elevation is low and the load is large.The study investigates the possibilities to design the system and, in particular, the collector optics, in order to match the system performance with the yearly variations of the heating load and the solar irradiation. It seems possible to design practically viable load adapted collectors, and to use them for whole roofs ( 40 m2) without causing more overheating stress on the system than with a standard 10 m2 system. The load adapted collectors collect roughly as much energy per unit area as flat plate collectors, but they may be produced at a lower cost due to lower material costs. There is an additional potential for a cost reduction since it is possible to design the load adapted collector for low stagnation temperatures making it possible to use less expensive materials. One and the same collector design is suitable for a wide range of system sizes and roof inclinations. The report contains descriptions of optimized collector designs, properties of realistic collectors, and results of calculations of system output, stagnation performance and cost performance. Appropriate computer tools for optical analysis, optimization of collectors in systems and a very fast simulation model have been developed.
2

Thermal Performance of a Solarus CPC-Thermal Collector

Šumić, Mersiha January 2014 (has links)
The  aim  of  this  master  thesis  is  an  investigation  of  the  thermal  performance  of  a  thermal compound parabolic concentrating (CPC) collector from Solarus. The collector consists of two troughs with absorbers which are coated with different types of paint with  unknown  properties.  The  lower  and  upper  trough  of  the  collector  have  been  tested individually. In  order  to  accomplish  the  performance  of  the  two  collectors,  a  thorough  literature  study  in  the  fields  of  CPC  technology,  various  test  methods,  test  standards  for  solar thermal  collectors  as  well  as  the  latest  articles  relating  on  the  subject  were  carried  out. In addition, the set‐up of the thermal test rig was part of the thesis as well. The thermal  performance  was  tested  according  to  the  steady  state  test  method  as  described in the European standard 12975‐2. Furthermore, the thermal performance of  a  conventional  flat  plate  collector  was  carried  out  for  verification  of  the  test  method. The  CPC‐Thermal  collector  from  Solarus  was  tested  in  2013  and  the  results  showed  four  times  higher  values  of  the  heat  loss  coefficient  UL (8.4  W/m²K)  than  what  has been reported for a commercial collector from Solarus. This value was assumed to be too large and it was assumed that the large value was a result of the test method used that time. Therefore, another aim was the comparison of the results achieved in this work with the results from the tests performed in 2013. The results of the thermal performance showed that the optical efficiency of the lower trough of the CPC‐T collector is 77±5% and the corresponding heat loss coefficient UL 4.84±0.20  W/m²K.  The  upper  trough  achieved  an  optical  efficiency  of  75±6  %  and  a  heat loss coefficient UL of 6.45±0.27 W/m²K. The results of the heat loss coefficients  are  valid  for  temperature  intervals  between  20°C  and  80°C.  The  different  absorber paintings have a significant impact on the results, the lower trough performs overall better.  The  results  achieved  in  this  thesis  show  lower  heat  loss  coefficients UL and higher optical efficiencies compared to the results from 2013.
3

Optical Efficiency of Low-Concentrating Solar Energy Systems with Parabolic Reflectors

Brogren, Maria January 2004 (has links)
<p>Solar electricity is a promising energy technology for the future, and by using reflectors for concentrating solar radiation onto photovoltaic cells, the cost per produced kWh can be significantly reduced. The optical efficiency of a concentrating system determines the fraction of the incident energy that is transferred to the cells and depends on the optical properties of the system components. In this thesis, low-concentrating photovoltaic and photovoltaic-thermal systems with two-dimensional parabolic reflectors were studied and optimised, and a new biaxial model for the incidence angle dependence of the optical efficiency was proposed.</p><p>Concentration of light generally results in high cell temperatures, and the uneven irradiance distribution on cells with parabolic reflectors leads to high local currents and temperatures, which reduce fill-factor and voltage. Cooling the cells by means of water increases the voltage and makes it possible to utilize the thermal energy. The performance of a 4X concentrating photovoltaic-thermal system was evaluated. If operated at 50°C, this system would produce 250 kWh<sub>electrical</sub> and 800 kWh<sub>thermal</sub> per m<sup>2</sup> cell area and year. Optical performance can be increased by 20% by using better reflectors and anti-reflectance glazing.</p><p>Low-concentrating photovoltaic systems for façade-integration were studied and optimised for maximum annual electricity production. The optimisation was based on measured short-circuit currents versus solar altitude. Measurements were performed outdoors and in a solar simulator. It was found that the use of 3X parabolic reflectors increases the annual electricity production by more than 40%. High solar reflectance is crucial to system performance but by using a low-angle scattering reflector, the fill-factor and power are increased due to a more even irradiance on the modules.</p><p>Long-term system performance depends on the durability of the components. The optical properties and degradation of reflector materials were assessed using spectrophotometry, angular resolved scatterometry, Fresnel modelling, optical microscopy, and surface profilometry before and after ageing. The degradation of reflectors was found to be strongly dependent on material composition and environmental conditions. Back surface mirrors, all-metal reflectors, and polymer-metal laminates degraded in different ways, and therefore accelerated ageing must be tailored for testing of different types of reflector materials. However, new types of reflector laminates showed a potential for increasing the cost-effectiveness of low-concentrating solar energy systems.</p>
4

Optical Efficiency of Low-Concentrating Solar Energy Systems with Parabolic Reflectors

Brogren, Maria January 2004 (has links)
Solar electricity is a promising energy technology for the future, and by using reflectors for concentrating solar radiation onto photovoltaic cells, the cost per produced kWh can be significantly reduced. The optical efficiency of a concentrating system determines the fraction of the incident energy that is transferred to the cells and depends on the optical properties of the system components. In this thesis, low-concentrating photovoltaic and photovoltaic-thermal systems with two-dimensional parabolic reflectors were studied and optimised, and a new biaxial model for the incidence angle dependence of the optical efficiency was proposed. Concentration of light generally results in high cell temperatures, and the uneven irradiance distribution on cells with parabolic reflectors leads to high local currents and temperatures, which reduce fill-factor and voltage. Cooling the cells by means of water increases the voltage and makes it possible to utilize the thermal energy. The performance of a 4X concentrating photovoltaic-thermal system was evaluated. If operated at 50°C, this system would produce 250 kWhelectrical and 800 kWhthermal per m2 cell area and year. Optical performance can be increased by 20% by using better reflectors and anti-reflectance glazing. Low-concentrating photovoltaic systems for façade-integration were studied and optimised for maximum annual electricity production. The optimisation was based on measured short-circuit currents versus solar altitude. Measurements were performed outdoors and in a solar simulator. It was found that the use of 3X parabolic reflectors increases the annual electricity production by more than 40%. High solar reflectance is crucial to system performance but by using a low-angle scattering reflector, the fill-factor and power are increased due to a more even irradiance on the modules. Long-term system performance depends on the durability of the components. The optical properties and degradation of reflector materials were assessed using spectrophotometry, angular resolved scatterometry, Fresnel modelling, optical microscopy, and surface profilometry before and after ageing. The degradation of reflectors was found to be strongly dependent on material composition and environmental conditions. Back surface mirrors, all-metal reflectors, and polymer-metal laminates degraded in different ways, and therefore accelerated ageing must be tailored for testing of different types of reflector materials. However, new types of reflector laminates showed a potential for increasing the cost-effectiveness of low-concentrating solar energy systems.
5

Development and Thermal Management of a Dynamically Efficient, Transient High Energy Pulse System Model

Butt, Nathaniel J. 08 June 2018 (has links)
No description available.
6

Comportamiento Óptico y Térmico de un Concentrador Solar Lineal con reflector estacionario y Foco Móvil

Pujol Nadal, Ramon 30 July 2012 (has links)
El concentrador solar Fixed Mirror Solar Concentrator (FMSC) apareció en los años 70 con la finalidad de reducir costes en la producción de energía termoeléctrica. Este diseño consiste en un concentrador de reflector estacionario y foco móvil, presenta buena integrabilidad en cubiertas, y es capaz de alcanzar temperaturas entre 100 y 200ºC manteniendo una eficiencia aceptable. En esta tesis se expone una metodología para determinar el comportamiento del FMSC. Se ha desarrollado una herramienta de cálculo basada en el método de ray-tracing, que simula el trazado de los rayos solares en el sistema óptico. Con esta herramienta se ha analizado el comportamiento óptico y térmico del FMSC, y de la versión con espejos curvos Curved Slats Fixed Mirror Solar Concentrator (CSFMSC). Se ha realizado un análisis paramétrico para conocer la influencia de los distintos parámetros en el modificador de ángulo (IAM), y para obtener los diseños óptimos a una temperatura de 200ºC para tres climas en diferentes latitudes. Se han comparado los valores teóricos obtenidos mediante ray-tracing con dos prototipos ensayados, obteniendo un buen ajuste en ambos casos. Los ensayos han sido utilizados para determinar la curva de rendimiento de uno de los prototipos. Se ha hecho uso del método propuesto en la norma EN-12975-2:2006, combinado con valores de IAM obtenidos mediante ray-tracing. Se prueba que esta combinación puede ser útil para obtener la curva de rendimiento de colectores complejos con un modelo biaxial para el IAM. / The Fixed Mirror Solar Concentrator (FMSC) appeared during the 70s with the aim of reducing costs in the production of electricity in solar thermal power plants. This design consists of a concentrator with fixed reflector and moving receiver, has a very good integrability into building roofs and can reach temperatures between 100 and 200ºC with an acceptable efficiency. In this Thesis a methodology is presented for the determination of the behaviour of the FMSC. A simulation tool based on the forward ray-tracing method has been developed. The optical and thermal behaviour of the FMSC and its curved mirror variation called the Curved Slats Fixed Mirror Solar Concentrator (CSFMSC), have been analyzed with this tool. A parametric analysis has been carried out in order to determine the influence of the different parameters on the Incidence Angle Modifier (IAM) and to determine the optimal designs at a temperature of 200ºC for three different climates at different latitudes. The theoretical values obtained from the ray-tracing code have been compared with two experimental prototypes. The experimental and numerical results obtained show a good fit. The efficiency curve of one of the prototypes has been determined from the experimental tests. The methodology proposed in the norm EN-12975-2:2006 has been used in combination with IAM values obtained by ray-tracing. It has been shown that this combination can be effectively used to obtain the efficiency curve of complex collectors with a bi-axial IAM model.

Page generated in 0.0635 seconds