• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 287
  • 264
  • 38
  • 10
  • 9
  • 7
  • 6
  • 5
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 672
  • 255
  • 142
  • 127
  • 125
  • 118
  • 117
  • 95
  • 84
  • 79
  • 61
  • 58
  • 58
  • 55
  • 55
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

The effect of fixed orthodontic appliances on the oral carriage of Candida species and coliforms in adolescents /

Paporn, Kaveewatcharanont. January 1993 (has links)
Thesis (M.D.S.)--University of Hong Kong, 1993. / Photocopy of original typescript.
202

The effect of fixed orthodontic appliances on the oral carriage of Candida species and coliforms in adolescents

Paporn, Kaveewatcharanont. January 1993 (has links)
Thesis (M.D.S.)--University of Hong Kong, 1993. / Also available in print.
203

Patient-specific 3D finite-element analysis of miniscrew implants during orthodontic treatment

Ammar, Hussein. January 1900 (has links)
Thesis (M.S.)--West Virginia University, 2010. / Title from document title page. Document formatted into pages; contains xvi, 94 p. : ill. (some col.). Includes abstract. Includes bibliographical references (p. 81-94).
204

A comparison of treatment impacts between invisalign and fixed appliance therapy during the first seven days of treatment

Miller, Kevin Blaine. January 2005 (has links)
Thesis (Ph.D.)--University of Florida, 2005. / Typescript. Title from title page of source document. Document formatted into pages; contains 36 pages. Includes Vita. Includes bibliographical references.
205

Avaliacao dos efeitos do laser em baixa intensidade pela forca de mordida apos os separadores ortodonticos

PERON, GILDA M.M. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:52Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:06Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado Profissionalizante em Lasers em Odontologia) / IPEN/D-MPLO / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP; Faculdade de Odontologia, Universidade de Sao Paulo, Sao Paulo
206

Estudo clínico do tempo de fechamento de espaço e do movimento dentário durante a retratação de caninos entre dois tipos de braquetes

Monini, André da Costa [UNESP] 13 December 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-12-13Bitstream added on 2014-06-13T20:05:06Z : No. of bitstreams: 1 monini_ac_dr_arafo.pdf: 569037 bytes, checksum: 70156844614f17c25c89142213ee5c2e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O desenvolvimento tecnológico na fabricação de braquete trouxe consigo a ideia de que a tecnologia empregada no aparelho pode representar aumento na velocidade de movimentação dentária. O propósito deste estudo foi avaliar a taxa de movimentação mensal de caninos e a perda de ancoragem ocorrida durante o movimento de retração de caninos por deslizamento entre dois tipos de braquetes diferentes, um autoligado e outro convencionalmente ligado, bem como diferenças entre os arcos superior e inferior. A amostra consistiu de 25 pacientes biprotusos, portadores de má oclusão de classe I com necessidade de extração de quatro primeiros pré-molares para realização do tratamento ortodôntico, com apinhamento no arco superior e inferior menores que 4mm, idade variando entre 18 anos até 34 anos e sem ausências dentárias sendo facultativa a presença dos terceiros molares. Em todos eles foram colados dois braquetes autoligados, um no canino superior e outro no canino inferior de maneira randomizada e num sistema split-mouth. Os demais dentes receberam braquetes convencionais e tubos nos molares. Os primeiros pré-molares foram extraídos após o alinhamento e nivelamentos dos arcos e 7 a 15 dias após deu-se início à retração dos caninos. Telerradiografias laterais de 45º foram realizadas antes do início da retração e após a completa retração de cada canino. A superposição dos traçados cefalométricos iniciais e após a retração permitiu o cálculo da perda de ancoragem ocorrida e a quantidade de retração para cada canino. A divisão da quantidade de retração pelo tempo decorrido permitiu o cálculo da taxa de movimentação mensal dos caninos. Os resultados demonstraram que não existe diferença na taxa de movimentação mensal dos caninos e nem na perda de ancoragem entre os dois tipos de braquetes... / The technological development in bracket manufacturing brought with it the belief that enhanced technology might translate as faster in tooth movement. The aim of this study was to evaluate the monthly rate of canine movement as well as the rate of anchorage loss during the retraction of canines by sliding mechanics with two different types of brackets: self-ligated and conventional and also, as well as differences between upper and lower arches. The sample comprised 25 biprotusive class I patients with need of four bicuspid extractions for orthodontic treatment, with upper and lower crowding less than 4 mm, age between 18 and 34 years old and no missing teeth except for the third molars. In all of them selfligated brackets were randomly bonded on the upper and lower canines in a split mouth design. The remaining teeth were bonded and banded with conventional brackets. First bicuspids were extracted after leveling and alignment and after 7 to 15 days canine retraction was initiated. Forty-five degree radiographic were taken before retraction and after complete canine retaraction. Cephalometrics tracings before and after canine retraction allowed the measurement of the resultant anchorage loss and the amount of canine retraction. By dividing the amount of canine retraction by it allowed the calculation of the canine movement monthly rate. The results showed that there is no difference between the rate of canine monthly movement and loss of anchorage between the two types of bracket. When arches were compared, upper canines were found to move faster than the lower ones and no difference was found on anchorage loss. It was concluded that canine retraction by sliding mechanics with either brackets occur at the same rate as well as the loss of anchorage of the molars. Upper... (Complete abstract click electronic access below)
207

Efeito da terapia laser de baixa potencia no aumento da velocidade da movimentacao ortodontica

VIEIRA, RODRIGO R. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:38Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:27Z (GMT). No. of bitstreams: 1 13948.pdf: 4835457 bytes, checksum: 91031ccf645e496d6c45cf541eb91a26 (MD5) / Dissertacao (Mestrado Profissionalizante em Lasers em Odontologia) / IPEN/D-MPLO / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP; Faculdade de Odontologia, Universidade de Sao Paulo, Sao Paulo
208

Avaliação mecânica tridimensional de molas T compostas de NiTi e Aço / Tridimensional mechanical evaluation of NiTi and stainless steel composed T loop springs

Ribeiro, Alexandre Antonio [UNESP] 25 March 2015 (has links) (PDF)
Made available in DSpace on 2016-12-09T13:52:20Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-03-25. Added 1 bitstream(s) on 2016-12-09T13:55:24Z : No. of bitstreams: 1 000874741.pdf: 2115276 bytes, checksum: 22aa654fa4b88145cca778bd61f794f9 (MD5) / O fechamento de espaços por meio de molas T com a liga de Níquel-Titânio (NiTi) para a retração em massa ainda não foi estudada. A superelasticidade e memória de forma são propriedades desta liga interessantes para a movimentação dentária. Sendo assim, o objetivo foi determinar, por meio da avaliação tridimensional as melhores variações do design de molas T compostas para o fechamento de espaços em massa. Foram utilizadas cem molas compostas por alças T de NiTi e fios base de aço inoxidável, unidos por tubos cruzados. As molas foram divididas em grupos de 10 molas de acordo com o calibre do fio de NiTi, altura da mola, ativação horizontal ou ainda variações no raio de pré-ativação ou espessura do fio base. As molas foram testadas na máquina de ensaios OFT (Orthodontic Force Tester). Foram medidos força, momento e relação momento força (M:F) nos eixos de interesse. A análise multivariada de perfis foi aplicada para comparação dos grupos. Observou-se que as molas com médias de força horizontal adequadas para retração tem espessuras de 0,017 x 0,025 e 0,018 x 0,025 de NiTi. As variáveis altura da mola e ativação horizontal demonstraram interação durante a desativação para a variável força, entretanto, não demonstraram esta relação para momento e M:F. Observou-se que o melhor design das molas foi a altura de 7mm, ativação horizontal de 7mm e raio de pré-ativação de 6mm. Concluiu se que as molas compostas de NiTi compostas apresentaram propriedades adequadas para retração em massa, especialmente com pré-ativação 6mm de raio de curvatura. / The space closure with Nickel-Titanium alloy (NiTi) T-loop springs for en masse retraction has not been studied. Superelasticity and shape memory are NiTi properties interesting to tooth movement. The aim was to determine by assessing three dimensionally the best T-loop spring design to the en masse space. Were tested one hundred T-loop composed springs by handles of rectangular NiTi wires and stainless steel horizontal rods, joined by criss-cross tubes. The T-loop composed springs were divided in groups of ten springs according to the caliber of the NiTi wire, handles height, horizontal activation or variations of preactivation radius or thickness of the wire rods. The springs were tested in the OFT device (Orthodontic Force Tester) for measuring orthodontic force system. Mmultivariate analysis profiles was used to compare the groups along the deactivation and possible interaction between the variables under study. It was observed that composed T-loop springs showed adequate horizontal force average for en mass retraction 0.017 x 0.025 and 0.018 x 0.025 NiTi wires. The height handles and horizontal activation variables demonstrated interaction during off to the force variable, however, have not shown this relationship to moment and M:F. It was considered that the best design of T-loop was 7mm height, 7mm horizontal activation and pre-activation radius 6mm. It was concluded that composite NiTi T-loop springs showed adequate properties for en masse retraction...(Complete abstract electronic access below)
209

Avaliação mecânica tridimensional de molas T compostas de NiTi e Aço /

Ribeiro, Alexandre Antonio January 2015 (has links)
Orientador: Lidia Parsekian Martins / Co-orientador: Renato Parsekian Martins / Banca: Laurindo Zanco Furquim / Banca: José Nelson Mucha / Banca: Luis Geraldo Vaz / Banca: Ary dos Santos Pinto / Resumo: O fechamento de espaços por meio de molas T com a liga de Níquel-Titânio (NiTi) para a retração em massa ainda não foi estudada. A superelasticidade e memória de forma são propriedades desta liga interessantes para a movimentação dentária. Sendo assim, o objetivo foi determinar, por meio da avaliação tridimensional as melhores variações do design de molas T compostas para o fechamento de espaços em massa. Foram utilizadas cem molas compostas por alças T de NiTi e fios base de aço inoxidável, unidos por tubos cruzados. As molas foram divididas em grupos de 10 molas de acordo com o calibre do fio de NiTi, altura da mola, ativação horizontal ou ainda variações no raio de pré-ativação ou espessura do fio base. As molas foram testadas na máquina de ensaios OFT (Orthodontic Force Tester). Foram medidos força, momento e relação momento força (M:F) nos eixos de interesse. A análise multivariada de perfis foi aplicada para comparação dos grupos. Observou-se que as molas com médias de força horizontal adequadas para retração tem espessuras de 0,017" x 0,025" e 0,018" x 0,025" de NiTi. As variáveis altura da mola e ativação horizontal demonstraram interação durante a desativação para a variável força, entretanto, não demonstraram esta relação para momento e M:F. Observou-se que o melhor design das molas foi a altura de 7mm, ativação horizontal de 7mm e raio de pré-ativação de 6mm. Concluiu se que as molas compostas de NiTi compostas apresentaram propriedades adequadas para retração em massa, especialmente com pré-ativação 6mm de raio de curvatura. / Abstract: The space closure with Nickel-Titanium alloy (NiTi) T-loop springs for en masse retraction has not been studied. Superelasticity and shape memory are NiTi properties interesting to tooth movement. The aim was to determine by assessing three dimensionally the best T-loop spring design to the en masse space. Were tested one hundred T-loop composed springs by handles of rectangular NiTi wires and stainless steel horizontal rods, joined by criss-cross tubes. The T-loop composed springs were divided in groups of ten springs according to the caliber of the NiTi wire, handles height, horizontal activation or variations of preactivation radius or thickness of the wire rods. The springs were tested in the OFT device (Orthodontic Force Tester) for measuring orthodontic force system. Mmultivariate analysis profiles was used to compare the groups along the deactivation and possible interaction between the variables under study. It was observed that composed T-loop springs showed adequate horizontal force average for en mass retraction 0.017 "x 0.025" and 0.018 "x 0.025" NiTi wires. The height handles and horizontal activation variables demonstrated interaction during off to the force variable, however, have not shown this relationship to moment and M:F. It was considered that the best design of T-loop was 7mm height, 7mm horizontal activation and pre-activation radius 6mm. It was concluded that composite NiTi T-loop springs showed adequate properties for en masse retraction...(Complete abstract electronic access below) / Doutor
210

Estudo clínico do tempo de fechamento de espaço e do movimento dentário durante a retratação de caninos entre dois tipos de braquetes /

Monini, André da Costa. January 2012 (has links)
Orientador: Luiz Gonzaga Gandini Junior / Banca: Ary dos Santos-Pinto / Banca: Dirceu Barnabé Raveli / Banca: Claudio de Góis Nery / Banca: Marcos Augusto Lenza / Resumo: O desenvolvimento tecnológico na fabricação de braquete trouxe consigo a ideia de que a tecnologia empregada no aparelho pode representar aumento na velocidade de movimentação dentária. O propósito deste estudo foi avaliar a taxa de movimentação mensal de caninos e a perda de ancoragem ocorrida durante o movimento de retração de caninos por deslizamento entre dois tipos de braquetes diferentes, um autoligado e outro convencionalmente ligado, bem como diferenças entre os arcos superior e inferior. A amostra consistiu de 25 pacientes biprotusos, portadores de má oclusão de classe I com necessidade de extração de quatro primeiros pré-molares para realização do tratamento ortodôntico, com apinhamento no arco superior e inferior menores que 4mm, idade variando entre 18 anos até 34 anos e sem ausências dentárias sendo facultativa a presença dos terceiros molares. Em todos eles foram colados dois braquetes autoligados, um no canino superior e outro no canino inferior de maneira randomizada e num sistema split-mouth. Os demais dentes receberam braquetes convencionais e tubos nos molares. Os primeiros pré-molares foram extraídos após o alinhamento e nivelamentos dos arcos e 7 a 15 dias após deu-se início à retração dos caninos. Telerradiografias laterais de 45º foram realizadas antes do início da retração e após a completa retração de cada canino. A superposição dos traçados cefalométricos iniciais e após a retração permitiu o cálculo da perda de ancoragem ocorrida e a quantidade de retração para cada canino. A divisão da quantidade de retração pelo tempo decorrido permitiu o cálculo da taxa de movimentação mensal dos caninos. Os resultados demonstraram que não existe diferença na taxa de movimentação mensal dos caninos e nem na perda de ancoragem entre os dois tipos de braquetes... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The technological development in bracket manufacturing brought with it the belief that enhanced technology might translate as faster in tooth movement. The aim of this study was to evaluate the monthly rate of canine movement as well as the rate of anchorage loss during the retraction of canines by sliding mechanics with two different types of brackets: self-ligated and conventional and also, as well as differences between upper and lower arches. The sample comprised 25 biprotusive class I patients with need of four bicuspid extractions for orthodontic treatment, with upper and lower crowding less than 4 mm, age between 18 and 34 years old and no missing teeth except for the third molars. In all of them selfligated brackets were randomly bonded on the upper and lower canines in a split mouth design. The remaining teeth were bonded and banded with conventional brackets. First bicuspids were extracted after leveling and alignment and after 7 to 15 days canine retraction was initiated. Forty-five degree radiographic were taken before retraction and after complete canine retaraction. Cephalometrics tracings before and after canine retraction allowed the measurement of the resultant anchorage loss and the amount of canine retraction. By dividing the amount of canine retraction by it allowed the calculation of the canine movement monthly rate. The results showed that there is no difference between the rate of canine monthly movement and loss of anchorage between the two types of bracket. When arches were compared, upper canines were found to move faster than the lower ones and no difference was found on anchorage loss. It was concluded that canine retraction by sliding mechanics with either brackets occur at the same rate as well as the loss of anchorage of the molars. Upper... (Complete abstract click electronic access below) / Doutor

Page generated in 0.0308 seconds