• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 51
  • 44
  • 8
  • 2
  • 1
  • Tagged with
  • 109
  • 109
  • 46
  • 41
  • 32
  • 28
  • 24
  • 23
  • 22
  • 20
  • 18
  • 16
  • 15
  • 15
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Avaliação de enxaguatório bucais na atividade biológica do biofilme formado em braquetes ortodônticos / Evaluation of oral Rinses in biological activity of biofilm formed in orthodontic brackets

Bussadori, Celene Marques 25 September 2013 (has links)
Na Odontologia, existe uma grande preocupação com a formação de placa bacteriana ou biofilme devido ao seu potencial cariogênico. Essa atenção se estende à ortodontia, devido ao acúmulo de biofilme formado nos aparelhos ortodônticos, tanto nos aparelhos removíveis quanto nos aparelhos fixos. É muito comum a presença de lesões brancas após a remoção dos bráquetes, em torno de 50 a 75% dos pacientes, provocadas pela presença do biofilme. É necessário um controle químico e mecânico rigoroso, a fim de se evitar alterações irreversíveis nos dentes e periodonto. O controle mecânico se dá pela escovação adequada, pelo correto uso de fio dental e pela frequência desses hábitos, além, claro, de um acompanhamento profissional periódico. O controle químico pode ser viabilizado pelo uso de enxaguatórios bucais, nos quais residem alguns efeitos indesejáveis e contraindicações relacionadas ao uso e à idade dos pacientes. Este estudo tem como objetivo avaliar comparativamente dois enxaguatórios bucais, um de natureza comercial (Cepacol®), e outro não comercial, elaborado com extratos hidroalcoólicos das plantas Nasturtium officinale (agrião), Rosmarinus offinalis (alecrim), Tabebuia impetiginosa (ipê roxo), Achillea millefolium (mil folhas) e Plantago major (tanchagem), desenvolvido na Faculdade de Ciências Farmacêuticas/UNESP Araraquara. Foram selecionados 40 pacientes, jovens e adultos, entre 18 e 45 anos, usuários de aparelho ortodôntico corretivo (fixo), divididos em dois grupos, o grupo do Cepacol e o grupo do Enxaguatório base de plantas. Foram coletadas amostras nos períodos de 0, 7, 15 e 21 dias e analisadas observando-se as Unidades Formadoras de Colônia (UFC) de cada amostra. Houve uma queda significativa da quantidade de bactérias após o uso do Enxaguatório à base de plantas, revelando um produto de extrema utilidade no auxílio do controle do biofilme bacteriano nas superfícies dentárias. / In dentistry, there is a great concern with the formation of plaque or biofilm, due to its cariogenic potential. This attention extends to orthodontics due to the accumulation of biofilm on orthodontic appliances, removable appliances as much in the brackets. It is very common the presence of white spots after removal of the brackets, around 50 to 75% of patients, which are caused by biofilms. It takes a rigorous mechanical and chemical control in order to avoid irreversible changes in the teeth and periodontium. The mechanical control is by proper brushing, correct flossing and also the frequency of these habits, besides, of course, a periodical professional monitoring. Chemical control can be achieved by the use of mouthwashes, home to some undesirable effects and contraindications related to the use and age of patients. This study aimed to assess two mouthwashes, a commercial type (Cepacol ®) and other non-commercial, made with hydroalcoholic extracts of plants Nasturtium officinale (watercress), offinalis Rosmarinus (rosemary), Tabebuia impetiginosa ( purple ipe), Achillea millefolium (thousand leaves) and Plantago major (plantain), developed at the Faculty of Pharmaceutical Sciences / UNESP Araraquara. We selected 40 patients, young and adults between 18 and 45 years, users of orthodontic appliance (fixed), divided into two groups, the Cepacol group and the group of herbal mouthwash. Samples were collected during periods of 0, 7,15 and 21 days and analyzed by observing the Colony Forming Units (CFU) of each sample. There was a significant decrease in the amount of bacteria after using herbal mouthwash, revealing a product of the utmost use in aiding the control of bacterial biofilms on tooth surfaces.
52

Preferência e percepção do desconforto por pacientes adultos submetidos a tratamento ortodôntico com bráquetes convencionais e autoligáveis : um estudo clínico randomizado split-mouth /

Shibasaki, Wendel Minoro Muniz January 2019 (has links)
Orientador: Renato Parsekian Martins / Resumo: Introdução: O ortodontista necessita ponderar entre a melhor evidência científica disponível, a sua experiência profissional e as preferências do paciente para a tomada de decisão clínica. A decisão entre bráquetes autoligáveis (BA) ou convencionais (BC) pode ser fundamentada com estudos comparando sua eficiência clínica e aspectos profissionais de manuseio dos bráquetes, mas poucos estudos abordam as percepções do paciente e nenhum compara e quantifica a preferência e a percepção de desconforto dos pacientes, distinguindo-a da sensibilidade dolorosa. Um estudo clínico randomizado e controlado split-mouth de centro único foi conduzido com esse objetivo. Métodos: Vinte e seis participantes com média de 28,8(11,5) anos, com má oclusão simétrica, foram convocados para participar da pesquisa. Cada paciente teve um hemiarco superior randomizado para instalação de BA, enquanto o hemiarco contralateral era instalado os BC, ao mesmo tempo (T0). O cegamento apenas foi possível para o pesquisador. A preferência foi consultada após 30 dias e quantificada pela técnica willigness-to-pay (WTP), enquanto o nível de desconforto foi medido por escala visual analógica (EVA) antes da instalação(T0), imediatamente após a instalação (T1), 7 dias após a instalação (T2) e 30 dias após a instalação e com fio amarrado (T3). Índices de placa (IP) e gengival(IG) foram feitos em T0 e T3. Resultados: Os pacientes percebem diferença entre os modelos usados. Ao final, 17 pacientes preferiram os bráquetes c... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: ABSTRACT Introduction: The orthodontist needs to balance between the best available scientific evidence, his professional experience and the patient's preferences for clinical decision-making. The decision between self-ligating (SLB) or conventional (CB) brackets can be based on studies comparing their clinical efficiency and professional aspects of bracket manipulation, but few studies address the patient's perceptions and none compares and quantifies preference and perception of discomfort of patients, distinguishing it from pain sensitivity. A single-center, randomized, controlled split-mouth trial was conducted with this goal. Methods: Twenty-six participants with a mean age of 28.8 (11.5) years with symmetric malocclusion were invited to participate in the study. Each patient had a superior hemiarch randomized to bonding SLB, while the contralateral hemiarch had CB bonded at the same time (T0). Blinding was only possible for the researcher. The preference was consulted after 30 days and quantified by the willigness-to-pay (WTP) technique, while the level of discomfort was measured by visual analogue scale (VAS) before bonding (T0), immediately after bonding (T1), 7 days after bonding (T2) and 30 days after bonding and with wire tied (T3). Plaque and gingival index were made in T0 and T3. Results: Patients perceive difference between the models used. In the end, 17 patients preferred the conventional, while 9 preferred the self-ligation brackets. Patients who chose CBs we... (Complete abstract click electronic access below) / Doutor
53

Avaliação dos efeitos do Sistema Damon nas inclinações dentárias, dimensões dos arcos e suporte ósseo alveolar por meio da tomografia computadorizada de feixe cônico / Changes in arch dimensions, buccolingual inclinations and alveolar bony support during alignment using Damon MX: a CBCT study

Juliana Fernandes de Morais 28 November 2012 (has links)
Avaliação dos efeitos do Sistema Damon nas inclinações dentárias, dimensões dos arcos e suporte ósseo por meio da tomografia computadorizada de feixe cônico Este estudo objetivou analisar as alterações nas inclinações vestibulolinguais dos dentes, nas dimensões dos arcos e nas espessuras das tábuas ósseas vestibulares durante o alinhamento com Sistema Damon, como também identificar fatores pré-tratamento (espessura óssea inicial, larguras dos arcos, apinhamento) e alterações do tratamento (expansão dos arcos, vestibularização dos dentes) possivelmente associados. Vinte e dois adolescentes com dentadura permanente completa até primeiros molares, tratados sem extrações e apinhamento inicial mínimo de 4mm superior: -6,71mm (DP 2,99), inferior: -5,12mm (DP 2,03) foram escaneados por tomografia computadorizada de feixe cônico (TCFC) antes (T0) e após (T1) o alinhamento com o Sistema Damon. As dimensões dos arcos e as inclinações vestibulolinguais dos dentes foram avaliadas a partir das TCFC (T0 e T1) em modelos 3D e cortes multiplanares, enquanto o apinhamento foi mensurado nos modelos de estudo (T0). A spessura das tábuas ósseas vestibulares nos ¾ coronais e ¼ apical da raiz dentária foram mensuradas por meio de imagens de tomográficas parassagitais (0,3mm de espessura) das duas fases T0 e T1, nas áreas de incisivos centrais superiores e de segundos pré-molares e primeiros molares superiores e inferiores. As variáveis foram submetidas ao teste de de Shapiro-Wilk para testar sua distribuição. As alterações de todas as variáveis de T0 para T1 foram comparadas por meio dos testes t pareado ou de Wilcoxon. A correlação entre as alterações das espessuras ósseas com os possíveis fatores associados foi verificada pelo coeficiente de correlação de Pearson ou teste de correlação de Spearman. O alinhamento com o Sistema Damon produziu expansões dos arcos associados à proclinação dos dentes e à redução na espessura óssea vestibular. As tábuas ósseas vestibulares tornaram-se não mensuráveis com o alinhamento em 25% das raízes mesiovestibulares dos primeiros molares superiores. A redução nas espessuras ósseas vestibulares mensuráveis, recobrindo os ¾ coronais da raiz, foi significante nas áreas de incisivo central superior (-13,22%), raiz mesiovestibular do primeiro molar superior (-20,54%) e raízes mesial e distal do primeiro molar inferior (-15,58% e -11,38%, respectivamente). Houve tendência ao aumento da espessura óssea vestibular da raiz distovestibular do primeiro molar superior (p= 0,051), provavelmente devido à rotação do molar com o alinhamento. A redução na espessura óssea vestibular durante o alinhamento dentário mostrou correlação positiva com a espessura óssea e apinhamento iniciais no arco superior, bem como com a distância inter-segundos-prémolares pré-tratamento no arco inferior. Os arcos mais expandidos durante a fase de alinhamento tenderam a sofrer maior redução nas espessuras ósseas vestibulares. Conclui-se que o Sistema Damon produz expansões dos arcos associados à redução óssea vestibular durante a fase de alinhamento. Dentes com ossos mais finos e apinhamentos mais severos antes do tratamento apresentam maior risco para redução na tábua óssea vestibular e a quantidade de expansão durante o tratamento pode potencializar esse efeito. / This study aimed first to assess the changes in teeth buccolingual inclinations, arch dimensions, and buccal bony plate thicknesses occurred during the alignment phase using a self-ligating brackets system (Damon MX). Secondly, to identify pre-treatment (initial bone thickness, initial arch widths, initial crowding) or treatment parameters (amount of expansion, amount of buccal tipping) that could act as risk predictors for buccal bone reduction during orthodontic treatment. Twenty-two adolescents with complete permanent dentition until first molars, minimum initial crowding of 4mm - maxillary: -6.71 mm (SD 2.99), mandibular: - 5.12 mm (SD 2.03) - treated without extractions were scanned by cone beam computed tomography (CBCT) before (T0) and after (T1) alignment using Damon System. Arch dimensions and teeth buccolingual inclinations were evaluated by means of digital models and multiplanar reconstructed images both obtained from CBCT (T0 and T1), crowding was measured on study casts (T0). Alveolar buccal bone thickness overlying the ¾ coronal and the ¼ apical of the root were measured in the areas of maxillary central incisors, as well as maxillary and mandibular premolars and first molars by means of cross-sectional images reconstructed with 0.3 mm thickness at T0 and T1, Distribution of the variables was verified by Shapiro-Wilks test. Changes in all variables from T0 to T1 were compared using paired t test or Wilcoxon test. The correlation between changes in bone thickness with its possible associated factors was assessed by Pearson correlation coefficient or Spearman correlation test. Alignment using Damon System produced substantial arch expansion associated with proclination of teeth and reduction in buccal bone thickness. The buccal bone plates overlying 25% of the mesiobuccal roots of the maxillary first molars became unmeasurable during the alignment phase. The reduction in the measurable buccal bone thickness, overlying the ¾ coronal root length, was significant in the areas of maxillary central incisor (-13.2%), mesiobuccal root of maxillary first molar (-20.5%), mesial and distal roots of mandibular first molar (-15.6% and -11.4%, respectively). There was a tendency for increasing buccal bone thickness root overlying the distobuccal root of maxillary first molar (p = 0.051), probably due to molar rotation during the alignment phase. The reduction in buccal bone thickness during alignment with Damon System showed a positive correlation with initial bone thickness and initial crowding in the maxillary arch, and the pre-treatment inter-secondpremolar width in the mandibular arch. The more expanded the arch during the alignment phase, the greater reduction in buccal thickness bone. It is concluded that the Damon system produces arch expansion associated with decrease in buccal bone thickness during the alignment phase. Thinner buccal bony plates and more severe crowding before treatment increase the risk for buccal bone reduction and the amount of expansion during treatment may further enhance this effect.
54

Alterações das dimensões dos arcos dentários e das inclinações dos incisivos produzidas pelo Sistema Damon / Arch width and incisor torque changes produced by the Damon System

Valeria Matos Bezerra 19 December 2012 (has links)
PROPOSIÇÃO: O objetivo deste trabalho foi descrever as alterações das dimensões dos arcos dentários e das inclinações dos incisivos produzidas pelo Sistema Damon, durante a fase de alinhamento e nivelamento. Outro objetivo foi verificar a correlação destas alterações com o padrão de crescimento dos indivíduos. MATERIAL E MÉTODOS: modelos de estudo, telerradiografias convencionais e telerradiografias reconstruídas a partir de tomografias computadorizadas cone-beam de 22 casos tratados com o bráquetes Damon 3MXTM foram avaliados durante a fase de alinhamento e nivelamento. Os modelos de estudo foram obtidos ao início do tratamento (T0), após a primeira troca de fio (T1) e na inserção do fio de aço 0,019 x 0,025 (T2). Foram verificados os comprimentos de arco e as dimensões transversais nas regiões de caninos, primeiros e segundos pré-molares e primeiros molares mensuradas a partir das pontas de cúspides e margens gengivais linguais dos dentes, a cada etapa. Nas telerradiografias foram verificadas as alterações das inclinações dos incisivos inferiores e superiores, bem como o padrão de crescimento dos indivíduos. RESULTADOS: os comprimentos dos arcos e todas as distâncias transversais apresentaram aumentos significantes, com exceção da distância intercervical dos caninos superiores; houve aumento significante das inclinações vestibulares dos incisivos superiores e inferiores; o padrão de crescimento dos pacientes apresentou correlação significante com os aumentos transversais na região de pré-molares inferiores. CONCLUSÕES: o alinhamento e nivelamento de casos tratados sem extrações com o uso do Sistema Damon resultou no aumento significante das dimensões dos arcos dentários e das inclinações dos incisivos para vestibular. / OBJECTIVE: This study aimed to evaluate the dental arch widths and incisor torque changes produced by the Damon System during leveling and alignment. Other objective was to verify the correlation between these changes and the growth pattern. MATHERIAL AND METHODS: study casts and lateral radiographs derived from cone-beam computed tomographies of 22 subjects treated with Damon 3MXTM brackets were evaluated. The study casts were obtained at the start of treatment (T0), the first archwire change (T1), and the placement of the final 0,019 x 0,025-in archwire (T2). Arch depth and widths (intercanine, interpremolar and intermolar) were assessed at each stage. The incisor torques changes and the growth pattern were measured on the cephalometric records at T0 and T2. RESULTS: There was significant increase of the arch depths and lateral expansion of the arches for all measures, except for the intercervical of maxillary canines. The maxillary and mandibular incisors were significantly tipped labially; the growth pattern showed significant correlation with the lateral increases in lower premolars region. CONCLUSIONS: nonextraction cases treated with Damon System show significant increases in arch dimensions and incisors proclination.
55

Resistência ao cisalhamento de bráquetes ortodônticos após envelhecimento artificial acelerado / Shear bond strength of orthodontic brackets after accelerated artificial aging

Drubi Filho, Brahim 09 December 2011 (has links)
O propósito deste estudo foi comparar a resistência ao cisalhamento (RC) e o índice de remanescente adesivo (IRA) após Envelhecimento Artificial Acelerado (EAA) de bráquetes ortodônticos metálicos fixados com compósitos autopolimerizável (Concise Ortodôntico - CS, 3M Unitek) e fotoativado (Transbond Plus Color Change - TPCC, 3M Unitek) com diferentes tratamentos de superfície do esmalte. Foram selecionados 60 pré-molares humanos recém extraídos, que tiveram suas raízes embutidas em resina acrílica ativada quimicamente de forma que a face vestibular ficasse perpendicular ao plano horizontal. Estas foram limpas com pedra pomes e água por 10 segundos, lavadas e secas. Os dentes foram separados aleatoriamente em 5 grupos (n=12), segundo o tipo de tratamento de superfície do esmalte, e do compósito utilizado para fixação dos bráquetes: Grupo I - ácido fosfórico a 37% (Dental Gel, Dentsply) e CS; Grupo II - ácido fosfórico a 37% + Primer e CS; Grupo III - ácido fosfórico a 37% e TPCC; Grupo IV - ácido fosfórico a 37% + XT Primer (3M Unitek) e TPCC; e Grupo V Transbond Plus Self Etching Primer - SEP (3M Unitek) e TPCC. Após 24h da colagem dos bráquetes, metade das amostras de cada grupo (n=6) foi submetida ao EAA por 960 horas. Todas as amostras foram submetidas ao ensaio de resistência ao cisalhamento com cinzel em máquina universal de ensaios (DL 200, EMIC) na velocidade de 0,5 mm/min. Após a descolagem dos bráquetes, causada pelo teste de resistência ao cisalhamento, o IRA foi avaliado em lupa (10X) e quantificado a partir de escore (0-3). Os dados foram analisados estatisticamente (2-way ANOVA, Bonferroni, p<0,05) e verificou-se que não houve diferença estatisticamente significante entre os Grupos em função do EAA (p>0,05). Quando comparados os sistemas adesivos utilizados, verificou-se que o Grupo II sem EAA, apresentou a maior média de RC, resultado estatisticamente significante (p<0,05) em relação aos grupos III e V, que apresentou a menor média de RC. Quanto ao IRA, todos os grupos sem EAA apresentaram maior frequência do índice 3. Com EAA, houve aumento de frequência dos índices 1 e 2. Concluiu-se que o EAA não influenciou a RC de bráquetes ao dente, mas diminuiu a área de remanescente adesivo sobre o dente. / The purpose of this study was to compare the shear bond strength (SBS) and the adhesive remnant index (ARI) after Accelerated Artificial Aging (AAA) of metal orthodontic brackets bonded with self-polymerizing (Concise Ortodôntico - CS, 3M Unitek) and light activated (Transbond Plus Color Change - TPCC, 3M Unitek) composites, to enamel with different surface treatments. Sixty recently-extracted human premolars were selected. Their roots were embedded in chemically activated acrylic resin so that the vestibular face was perpendicular to the horizontal plane. They were cleaned with pumice stone and water for 10 seconds, washed and dried. The teeth were randomly separated into 5 groups (n=12), according to the type of enamel surface treatment, and composite used for bracket bonding: Group I - 37% phosphoric acid (Dental Gel, Dentsply) and CS; Group II - 37% phosphoric acid + Primer and CS; Group III - 37% phosphoric acid and TPCC; Group IV - 37% phosphoric acid + XT Primer (3M Unitek) and TPCC; and Group V Transbond Plus Self Etching Primer - SEP (3M Unitek) and TPCC. Twenty-four hours after bracket bonding, half the samples from each group (n=6) were submitted to AAA for 960 hours. All the samples were submitted to shear bond strength testing with a chisel, in a Universal Test Machine (DL 200, EMIC) at a speed of 0.5 mm/min. After bracket debonding caused by the shear bond strength test, the ARI was evaluated under a loupe (10X) and quantified according to a score (0-3). Data were statistically analyzed (2-way ANOVA, Bonferroni, p<0.05) and it was verified that there was no statistically significant difference among Groups as a function of AAA (p>0.05). When comparing the adhesive systems used, it was verified that Group II without AAA showed the highest mean SBS, a statistically significant result (p<0.05) in comparison with Groups III and V, which showed the lowest mean SBS. As regards ARI, all the groups without AAA showed higher frequency of Index 3. With AAA, there was increased frequency of indexes 1 and 2. It was concluded that AAA did not influence SBS of brackets to the tooth, but diminished the area of adhesive remnant on the tooth.
56

Avaliação da resistência ao cisalhamento de braquetes colados com resinas ortodônticas fluoretadas

Rastelli, Márcia Cristina 22 February 2006 (has links)
Made available in DSpace on 2017-07-24T19:22:14Z (GMT). No. of bitstreams: 1 MarciaCristinaR.pdf: 1130793 bytes, checksum: 7d9d617dfc4b2b8f59066d8b013a6268 (MD5) Previous issue date: 2006-02-22 / The aim of this study was to evaluate the shear bond strength of brackets bonded with fluoride-releasing composite resins, and to compare them to a conventional resin. For this study, sixty premolars extracted due to orthodontic reasons were used, which were divided into three groups: Group 1- Concise (3M), Group 2- Ultrabond (Aditek do Brasil) and Group 3- Rely-a-bond (Reliance). All bonded specimens were stored in distilled water at 37°C for 24 hours and termocycled between 5°C and 55°C for 500 cycles. After 48 hours, the specimens were submitted to the shear bond strength test, in occluso-gingival direction, in Material Test System MTS 810 machine, with load speed of 0.5 mm/min. Variance Analysis, Levene Test, Shapiro-Wilk Test and Tukey Test were used for data analysis. The results demonstrated a mean shear bond strength of 24.54 ± 6.98 MPa for the Concise; 11.53 ± 6.20 MPa for the Ultrabond; and of 16.46 ± 5.72 MPa for the Rely-a-Bond. Variance Analysis determined a statistical difference amongst groups (p<0.001). Tukey Test evidenced that the averages of the three groups were significantly different among themselves (p<0.05), with the highest resistance for the Concise Group and the lowest for the Ultrabond Group. However, all the materials presented bond strengths, which were suitable for clinical use. / O objetivo deste estudo foi avaliar a resistência ao cisalhamento de braquetes colados com resinas que contém flúor, e compará-las a uma resina convencional. Para este estudo, foram utilizados 60 pré-molares extraídos por motivo ortodôntico, os quais foram divididos em 3 grupos, sendo 20 corpos-de-prova para cada um: Grupo I - Concise (3M), Grupo II – Ultrabond (Aditek do Brasil) e Grupo III - Rely-a-Bond (Reliance). Todos os corpos-de-prova foram armazenados em água destilada a 37°C, por 24 horas e termociclados com 500 ciclos, nas temperaturas de 5°C e 55°C. Após 48 horas, os corpos-de-prova foram submetidos aos ensaios mecânicos de cisalhamento na direção ocluso-cervical, na máquina Material Test System MTS 810, com velocidade de carga de 0,5 mm/min. Para a análise dos dados, utilizou-se a Análise de Variância, Teste de Levene, Teste de Shapiro-Wilk e o Teste de Tukey. Os resultados demonstraram uma resistência média ao cisalhamento de 24,54 ± 6,98 MPa para o Grupo I (Concise), de 11,53 ± 6,20 MPa para o Grupo II (Ultrabond) e de 16,46 ± 5,72 MPa para o Grupo III (Rely-a-Bond). A Análise de Variância determinou diferença estatística entre as médias de resistência ao cisalhamento entre os grupos (p<0,001). O teste de Tukey evidenciou que as médias dos três grupos foram significativamente diferentes entre si (p<0,05), com a maior resistência para o Grupo I (Concise) e a menor para o Grupo II (Ultrabond). Entretanto, todos os materiais apresentaram resistência adesiva adequada para uso clínico.
57

Resistência ao cisalhamento de bráquetes ortodônticos cerâmicos colados com diferentes compósitos e irradiados com laser de CO2 / Shear strength of ceramic orthodontic brackets bonded with different composites and irradiated with CO2 laser

Denise de Souza Matos 25 April 2013 (has links)
O objetivo do trabalho foi avaliar a resistência ao cisalhamento de bráquetes ortodônticos cerâmicos com base de retenção química e mecânica, colados com diferentes compósitos e irradiados com laser de CO2. Foram utilizados 120 pré-molares humanos hígidos, suas coroas foram incluídas em resina acrílica e as faces vestibulares planificadas e polidas com lixas d\'água até exposição de 5mm esmalte. Posteriormente, as raízes dos dentes foram incluídas em tubos de PVC também com resina acrílica de forma que a face vestibular ficasse perpendicular à base do tubo. Os 120 corpos de prova foram divididos em 8 grupos (n=15), sendo 2 controles e 6 experimentais. Nos grupos 1 e 2 (controles) o compósito utilizado para colagem foi o Transbond XT, sendo que no grupo 1 foi colado o bráquete cerâmico Mystique (retenção mecânica) e no grupo 2 o bráquete cerâmico Fascination (retenção química). Nos grupos experimentais 3, 4 e 5 foi colado o bráquete Mystique com os compósitos Transbond XT, Concise e Z250, respectivamente. Nos grupos 6, 7 e 8 foi colado o bráquete Fascination com os mesmos compósitos dos grupos 3, 4 e 5, na mesma sequência. Nos grupos experimentais, após a colagem, os bráquetes foram irradiados com laser de CO2 com 10W de potência por 3 segundos e pulso de 0,01 segundo. Imediatamente após a irradiação foi realizado o teste de resistência ao cisalhamento da colagem em máquina universal de ensaios mecânicos (Emic DL 500) à velocidade de 0,5 mm/minuto. Após o teste, as superfícies avaliadas por meio do Índice de Remanescente Adesivo (IRA) e submetidas à Microscopia Eletrônica de Varredura (MEV) para investigação de eventuais fraturas. Os dados de resistência ao cisalhamento foram submetidos à Análise de Variância ANOVA e posteriormente teste de Tukey. O teste de Mann-Whitney foi utilizado para a avaliação do IRA. Os resultados mostraram que os grupos experimentais apresentaram valores de resistência ao cisalhamento menores quando comparados aos controle (p 0,05). O bráquete Mystique (retenção mecânica) apresentou valores maiores de resistência ao cisalhamento e o compósito Z 250 foi o que apresentou menor força de adesão após irradiação com laser de CO2. Os grupos 5 e 8 foram os que apresentaram maior média do IRA e para todas as superfícies avaliadas o modo de fratura mais prevalente foi a fratura adesiva . Concluiu-se que o laser de CO2 foi eficaz como auxiliar na descolagem de bráquetes cerâmicos de retenção química e mecânica. / The objective of this study was to evaluate the shear strength of the ceramic orthodontic brackets based in chemical and mechanical restraint, bonded with different composites and irradiated with CO2 laser was evaluated. Healthy human premolars (120) were used and their crowns were embedded in acrylic resin and the buccal surfaces flattened and polished with sandpaper until exposure of 5 mm of enamel. Subsequently, the roots of the teeth were included in PVC pipes also with acrylic resin so that the labial surface was perpendicular to the base of the pipe. The 120 samples were divided into 8 groups (n = 15), 2 being the control groups and 6, the experimental groups. In groups 1 and 2 (controls) the composite used for bonding was Transbond XT. Group 1 was glued to the ceramic bracket Mystique (by mechanical retention) and the group 2, with ceramic bracket Fascination (by chemical restraint). In the experimental groups 3, 4 and 5 Mystique brackets were glued with Transbond XT, Concise and Z250, respectively. In groups 6, 7 and 8 the Fascination bracket were glued with the same composites of groups 3, 4 and 5 and in the same sequence. In the experimental groups, after bonding, the brackets were irradiated with CO2 laser with 10W of power for 3 seconds and per pulse 0.01 seconds. Immediately after irradiation shear strength tests were performed on shear bonding with mechanical universal testing machines (Emic DL 500) at a speed of 0.5 mm/minute. After testing, the surfaces were evaluated using the Adhesive Remnant Index (ARI) and submitted to scanning electron microscopy (SEM) to investigate possible fractures. The shear strength data were subjected to analysis of variance with ANOVA and Tukey test later. The Mann-Whitney test was used to evaluate the ARI. The results showed that experimental groups showed lower shear strength values, comparing to the control groups (p 0.05). The bracket Mystique (mechanical retention) showed higher shear strength values and the Z 250 composite showed the lowest adhesion strength after irradiation with CO2 laser. Groups 5 and 8 presented the highest average of IRA and for all the surfaces that were evaluated the most prevalent fracture mode was the adhesive one. It was concluded that the CO2 laser was effective as an aid in bracket debonding of ceramic with chemical and mechanical retention.
58

Avaliação dos efeitos do Sistema Damon nas inclinações dentárias, dimensões dos arcos e suporte ósseo alveolar por meio da tomografia computadorizada de feixe cônico / Changes in arch dimensions, buccolingual inclinations and alveolar bony support during alignment using Damon MX: a CBCT study

Morais, Juliana Fernandes de 28 November 2012 (has links)
Avaliação dos efeitos do Sistema Damon nas inclinações dentárias, dimensões dos arcos e suporte ósseo por meio da tomografia computadorizada de feixe cônico Este estudo objetivou analisar as alterações nas inclinações vestibulolinguais dos dentes, nas dimensões dos arcos e nas espessuras das tábuas ósseas vestibulares durante o alinhamento com Sistema Damon, como também identificar fatores pré-tratamento (espessura óssea inicial, larguras dos arcos, apinhamento) e alterações do tratamento (expansão dos arcos, vestibularização dos dentes) possivelmente associados. Vinte e dois adolescentes com dentadura permanente completa até primeiros molares, tratados sem extrações e apinhamento inicial mínimo de 4mm superior: -6,71mm (DP 2,99), inferior: -5,12mm (DP 2,03) foram escaneados por tomografia computadorizada de feixe cônico (TCFC) antes (T0) e após (T1) o alinhamento com o Sistema Damon. As dimensões dos arcos e as inclinações vestibulolinguais dos dentes foram avaliadas a partir das TCFC (T0 e T1) em modelos 3D e cortes multiplanares, enquanto o apinhamento foi mensurado nos modelos de estudo (T0). A spessura das tábuas ósseas vestibulares nos ¾ coronais e ¼ apical da raiz dentária foram mensuradas por meio de imagens de tomográficas parassagitais (0,3mm de espessura) das duas fases T0 e T1, nas áreas de incisivos centrais superiores e de segundos pré-molares e primeiros molares superiores e inferiores. As variáveis foram submetidas ao teste de de Shapiro-Wilk para testar sua distribuição. As alterações de todas as variáveis de T0 para T1 foram comparadas por meio dos testes t pareado ou de Wilcoxon. A correlação entre as alterações das espessuras ósseas com os possíveis fatores associados foi verificada pelo coeficiente de correlação de Pearson ou teste de correlação de Spearman. O alinhamento com o Sistema Damon produziu expansões dos arcos associados à proclinação dos dentes e à redução na espessura óssea vestibular. As tábuas ósseas vestibulares tornaram-se não mensuráveis com o alinhamento em 25% das raízes mesiovestibulares dos primeiros molares superiores. A redução nas espessuras ósseas vestibulares mensuráveis, recobrindo os ¾ coronais da raiz, foi significante nas áreas de incisivo central superior (-13,22%), raiz mesiovestibular do primeiro molar superior (-20,54%) e raízes mesial e distal do primeiro molar inferior (-15,58% e -11,38%, respectivamente). Houve tendência ao aumento da espessura óssea vestibular da raiz distovestibular do primeiro molar superior (p= 0,051), provavelmente devido à rotação do molar com o alinhamento. A redução na espessura óssea vestibular durante o alinhamento dentário mostrou correlação positiva com a espessura óssea e apinhamento iniciais no arco superior, bem como com a distância inter-segundos-prémolares pré-tratamento no arco inferior. Os arcos mais expandidos durante a fase de alinhamento tenderam a sofrer maior redução nas espessuras ósseas vestibulares. Conclui-se que o Sistema Damon produz expansões dos arcos associados à redução óssea vestibular durante a fase de alinhamento. Dentes com ossos mais finos e apinhamentos mais severos antes do tratamento apresentam maior risco para redução na tábua óssea vestibular e a quantidade de expansão durante o tratamento pode potencializar esse efeito. / This study aimed first to assess the changes in teeth buccolingual inclinations, arch dimensions, and buccal bony plate thicknesses occurred during the alignment phase using a self-ligating brackets system (Damon MX). Secondly, to identify pre-treatment (initial bone thickness, initial arch widths, initial crowding) or treatment parameters (amount of expansion, amount of buccal tipping) that could act as risk predictors for buccal bone reduction during orthodontic treatment. Twenty-two adolescents with complete permanent dentition until first molars, minimum initial crowding of 4mm - maxillary: -6.71 mm (SD 2.99), mandibular: - 5.12 mm (SD 2.03) - treated without extractions were scanned by cone beam computed tomography (CBCT) before (T0) and after (T1) alignment using Damon System. Arch dimensions and teeth buccolingual inclinations were evaluated by means of digital models and multiplanar reconstructed images both obtained from CBCT (T0 and T1), crowding was measured on study casts (T0). Alveolar buccal bone thickness overlying the ¾ coronal and the ¼ apical of the root were measured in the areas of maxillary central incisors, as well as maxillary and mandibular premolars and first molars by means of cross-sectional images reconstructed with 0.3 mm thickness at T0 and T1, Distribution of the variables was verified by Shapiro-Wilks test. Changes in all variables from T0 to T1 were compared using paired t test or Wilcoxon test. The correlation between changes in bone thickness with its possible associated factors was assessed by Pearson correlation coefficient or Spearman correlation test. Alignment using Damon System produced substantial arch expansion associated with proclination of teeth and reduction in buccal bone thickness. The buccal bone plates overlying 25% of the mesiobuccal roots of the maxillary first molars became unmeasurable during the alignment phase. The reduction in the measurable buccal bone thickness, overlying the ¾ coronal root length, was significant in the areas of maxillary central incisor (-13.2%), mesiobuccal root of maxillary first molar (-20.5%), mesial and distal roots of mandibular first molar (-15.6% and -11.4%, respectively). There was a tendency for increasing buccal bone thickness root overlying the distobuccal root of maxillary first molar (p = 0.051), probably due to molar rotation during the alignment phase. The reduction in buccal bone thickness during alignment with Damon System showed a positive correlation with initial bone thickness and initial crowding in the maxillary arch, and the pre-treatment inter-secondpremolar width in the mandibular arch. The more expanded the arch during the alignment phase, the greater reduction in buccal thickness bone. It is concluded that the Damon system produces arch expansion associated with decrease in buccal bone thickness during the alignment phase. Thinner buccal bony plates and more severe crowding before treatment increase the risk for buccal bone reduction and the amount of expansion during treatment may further enhance this effect.
59

Alterações das dimensões dos arcos dentários e das inclinações dos incisivos produzidas pelo Sistema Damon / Arch width and incisor torque changes produced by the Damon System

Bezerra, Valeria Matos 19 December 2012 (has links)
PROPOSIÇÃO: O objetivo deste trabalho foi descrever as alterações das dimensões dos arcos dentários e das inclinações dos incisivos produzidas pelo Sistema Damon, durante a fase de alinhamento e nivelamento. Outro objetivo foi verificar a correlação destas alterações com o padrão de crescimento dos indivíduos. MATERIAL E MÉTODOS: modelos de estudo, telerradiografias convencionais e telerradiografias reconstruídas a partir de tomografias computadorizadas cone-beam de 22 casos tratados com o bráquetes Damon 3MXTM foram avaliados durante a fase de alinhamento e nivelamento. Os modelos de estudo foram obtidos ao início do tratamento (T0), após a primeira troca de fio (T1) e na inserção do fio de aço 0,019 x 0,025 (T2). Foram verificados os comprimentos de arco e as dimensões transversais nas regiões de caninos, primeiros e segundos pré-molares e primeiros molares mensuradas a partir das pontas de cúspides e margens gengivais linguais dos dentes, a cada etapa. Nas telerradiografias foram verificadas as alterações das inclinações dos incisivos inferiores e superiores, bem como o padrão de crescimento dos indivíduos. RESULTADOS: os comprimentos dos arcos e todas as distâncias transversais apresentaram aumentos significantes, com exceção da distância intercervical dos caninos superiores; houve aumento significante das inclinações vestibulares dos incisivos superiores e inferiores; o padrão de crescimento dos pacientes apresentou correlação significante com os aumentos transversais na região de pré-molares inferiores. CONCLUSÕES: o alinhamento e nivelamento de casos tratados sem extrações com o uso do Sistema Damon resultou no aumento significante das dimensões dos arcos dentários e das inclinações dos incisivos para vestibular. / OBJECTIVE: This study aimed to evaluate the dental arch widths and incisor torque changes produced by the Damon System during leveling and alignment. Other objective was to verify the correlation between these changes and the growth pattern. MATHERIAL AND METHODS: study casts and lateral radiographs derived from cone-beam computed tomographies of 22 subjects treated with Damon 3MXTM brackets were evaluated. The study casts were obtained at the start of treatment (T0), the first archwire change (T1), and the placement of the final 0,019 x 0,025-in archwire (T2). Arch depth and widths (intercanine, interpremolar and intermolar) were assessed at each stage. The incisor torques changes and the growth pattern were measured on the cephalometric records at T0 and T2. RESULTS: There was significant increase of the arch depths and lateral expansion of the arches for all measures, except for the intercervical of maxillary canines. The maxillary and mandibular incisors were significantly tipped labially; the growth pattern showed significant correlation with the lateral increases in lower premolars region. CONCLUSIONS: nonextraction cases treated with Damon System show significant increases in arch dimensions and incisors proclination.
60

Laser de CO2 como auxiliar na remoção de bráquetes estéticos cerâmicos / CO2 laser-assisted debonding for esthetic ceramic brackets

Macri, Rodrigo Teixeira 02 May 2012 (has links)
Este estudo avaliou a eficiência do uso do laser de CO2 com comprimento de onda de 10,6 m como auxiliar na remoção de bráquetes estéticos cerâmicos. Para este estudo foram utilizados 105 pré-molares inferiores humanos recentemente extraídos, que receberam irradiações com laser de CO2 antes da descolagem dos bráquetes. Na primeira fase deste estudo, o objetivo foi mensurar e comparar a temperatura no compósito de colagem do bráquete e na câmara pulpar após aplicação do laser de CO2 , para observar a segurança para o esmalte, bem como se a temperatura era suficiente para fragilizar o compósito, facilitando a remoção do bráquete. Nesta etapa foram utilizados 30 pré-molares inferiores recentemente extraídos, sendo que cada um recebeu 4 irradiações com diferentes protocolos de maneira aleatória. Foram testados 12 diferentes protocolos variando o tempo de irradiação (3 e 5s), a duração do pulso (0,01 e 0,03s) e a potência (5, 8 e 10W). Cada protocolo foi utilizado por 10 vezes (n=10), totalizando 120 irradiações. Em todas as irradiações os corpos-de-prova foram imersos em banho térmico com água a 37º C. Foram encontrados 4 protocolos cuja variação da temperatura na polpa foi menor que 5,5º C, portanto compatível com a saúde da polpa. Na segunda etapa do estudo, o objetivo foi avaliar a resistência ao cisalhamento após a aplicação do laser utilizando os protocolos cuja temperatura na polpa não fosse superior a 5,5º C. Setenta e cinco pré-molares inferiores humanos foram divididos em 5 grupos, dos quais um não foi submetido à irradiação, sendo considerado Controle (C). Nos 4 grupos restantes, irradiações foram realizadas como descrito a seguir: Grupo I (potência 5W; tempo de pulso 0,01s; tempo de aplicação 3s), Grupo II (5W; 0,03s e 3s), Grupo III (8W; 0,01s e 3s) e Grupo IV (10W; 0,01s e 3s). Cada grupo foi formado por 15 corpos-de-prova (n=15). Após a descolagem do bráquete foi avaliado o Índice de Remanescente Adesivo (IRA). Após as mensurações e aplicação da Análise de Variância (ANOVA) e do teste de Tukey foi constatado que o único grupo que apresentou diminuição na força de remoção foi o IV (7,33 MPa) em relação ao grupo C (10,81 MPa) sendo assim considerado seguro e eficaz na diminuição da resistência do compósito. / This study evaluates the efficacy CO2 10,6 m laser-assisted debonding esthetic ceramic brackets. For this purpose it was used 105 recently extracted lower human premolars that were irradiated with CO2 laser before debonding. In the first phase, the objectives were to measure and compare the temperature in composite for bracket bonding and at the pulp chamber after CO2 laser irradiation, to observe the safety for enamel, as well the temperature was enough to softening the composite, making debonding bracket easier. In this part it was used 30 lower premolar recently extracted, and each one received 4 irradiations with different protocols, randomly choose. It was tested 12 different protocols varying time of irradiation (3 and 5s), pulse duration (0,01s e 0,03s) and power (5, 8 and 10W). Each protocol was repeated for 10 times (n=10), resulting 120 irradiations. In every irradiation the teeth tested were immerse in warm water bath at 37o C. It was found 4 protocols with pulp temperature lower than 5,5º C, so this is compatible with pulp health. In the second phase of this study, the objective was to evaluate the shear bond strength after laser irradiation, using the protocols with pulp chamber temperatures lower than 5,5º C. Seventy-five lower human premolars was shared in 5 groups. One group did not receive laser irradiation and considered Control (C) and the other groups the irradiation was made as it follows: Group I (power density 5W; pulse duration 0,01s; irradiation time 3s), Group II (5W; 0,03s, 3s), Group III (8W; 0,01s; 3s) and Group IV (10W; 0,01s; 3s). After results ANOVA and Tukey tests were made. Group IV presented lowering in SBS force (7,33 MPa) when compared with C (10,81MPa). This protocol was founded as a safe and efficient in softening composite layer.

Page generated in 0.0744 seconds