• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 224
  • 12
  • 12
  • 12
  • 12
  • 9
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 234
  • 140
  • 139
  • 122
  • 100
  • 97
  • 52
  • 48
  • 36
  • 34
  • 28
  • 28
  • 27
  • 27
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Estudo da osseointegração de implantes de liga Ti30Ta instalados sem estabilidade primária. Influência da associação adesivo fibrínico/ácido tranexâmico e da superfície bioativa /

Wada, Cristiane Mayumi. January 2016 (has links)
Orientador: Maria Cristina Rosifini Alves Rezende / Banca: Carlos Roberto Grandini / Banca: Claudia Eliana Bruno Marino / Resumo: Quando implantes de titânio são instalados imediatamente após a extração dentária podem ocorrer ancoragem primária diminuída e retardo e/ou deficiência do processo de osseointegração. Isto se dá em razão da ampla interface entre as paredes circundantes do alvéolo e a superfície do implante. Evidências científicas demonstram que a resposta dos biomateriais quando inseridos num organismo vivo não depende apenas da sua composição, mas, sobretudo de sua superfície. Particularmente para os implantes dentários, o uso de ligas, o processo de usinagem e os tratamentos superficiais irão determinar características essenciais no desempenho clínico desses dispositivos. A liga Ti30Ta é altamente biocompatível, apresenta boa combinação de elevada resistência e baixo módulo de elasticidade, demonstrando excelente indicação para uso biomédico. O propósito deste trabalho foi avaliar histomorfometricamente em ratos o reparo ósseo ao redor de implantes de liga Ti30Ta com supertfície bioativa (tratamento hidrotérmico/biomimético) e associados à adesivo fibrínico/ácido tranexâmico. Foram confeccionados 32 implantes de Titânio CP Grau 4 (Grupo A/Ticp) e 32 implantes da liga Ti30Ta (Grupo B/Ti30Ta), os quais foram divididos em grupos com 8 implantes cada: GA1(Ticp), GA2(Ticp/ácido fibrínico/ácido tranexâmico), GA3(Ticp/superfície bioativa), GA4(Ticp/ Superfície Bioativa/Adesivo Fibrínico Ácido Tranexâmico), GB1(Ti30Ta), GB2 (Ti30Ta/ ácido fibrínico/ácido tranexâmico), GB3 (Ti30Ta/ sup... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: When implants are installed immediately after tooth extraction it may occur decreased primary anchor and delay and/or deficiency of osseointegration process. This occur because of the large interface between the sorrounding walls of the socket and the surface of the implant. Scientific evidence shows that the response of biomaterials when inserted into a living organism depends not only on its composition, but mainly its surface. Particularly for dental implants, use of alloys, the process of machining and surface treatments will determine the essential clinical performance characteristics of these devices. The Ti-30T alloy is highly biocompatible and exhibits good combination of high strengh and low modulus of elasticity, demonstrating excellent indication for biomedical use. The purpose of this study was to evaluate histomorphometrically in rats bone healing around Ti-30Ta alloy implants with bioactive surface (hydrothermal/biomimetic treatment) and associated with fibrin gle/tranexamic acid. They were made 32 CP titanium Grade 4 (Group A/Ticp) and 32 implants of Ti-30Ta alloy (Group B/Ti-30Ta). These groups (n=8) were divided into groups . GA1 9Ticp), GA2 (Ticp/fibrin glue/tranexamic acid), GA3 (Ticp/bioactive surface) and GA4 (Ticp/bioactive surface/ fibrin glue/tranexamic acid) and GB1 (Ti-30Ta), GB2 (Ti-30Ta/ fibrin glue/ tranexamic acid), GB3 (Ti-30Ta bioactive surface) and GB4 (Ti-30Ta /bioactive surface/fibrin glue/tranexamic acid). The implants of Group A and B were identified, packed individually and sterilized by gamma irradiation and implanted in the righ tibia of 64 male rats. The animal were euthanized at 60 days postoperatively. The pieces were processed in MMA (Stevenel's blue/red Alizarin S) for histomorphometric analysis. The results showed statistically significant differences to both the contact percentage of bone / implant to bone as percentage area within the confines of the threads between the groups. Thus, superior... / Mestre
132

Análise do comportamento de ferramentas de corte com diferentes revestimentos e seu efeito sobre a geração de calor no osso / Alexsander Luiz Golin ; orientadora, Karin Soldatelli Borsato ; co-orientador, Ricardo Diego Torres

Golin, Alexsander Luiz January 2005 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2005 / Inclui bibliografia / Com o desenvolvimento de novas tecnologias nas áreas da bioengenharia, a ampliação dos conhecimentos voltados para novos materiais e novos processos tem sido bastante necessária. Para qualquer aplicação de determinado biomaterial, seja ele implantado ou t
133

Estudo experimental da colocação de implantes dentários de titânio com superfície tratada (Titamaxcm®), em área enxertada usando submucosa de intestino delgado porcino como condutor ósseo / Mauro Pessoa Gebran ; orientador, Fernando Greca

Gebran, Mauro Pessoa January 2012 (has links)
Tese (doutorado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2012 / Bibliografia: f. 39-42 / O objetivo desta pesquisa foi a análise da osseointegração dos implantes de titânio com superfície tratada colocados nos defeitos ósseos preenchidos com SID(submucosa de intestino delgado) como condutor ósseo e posterior exame mecânico de contratorque. No / The goal of this study was the analysis of the osseointegration of titanium implants with rough surface, placed on bone defects filled with SID (small intestinal submucosa) as a bone conductor and later a bone mechanical examination of contratorque was do
134

Reconstrução óssea aposicional com enxerto xenógeno associado à fração de células mononucleares da medula óssea na calvária de coelhos / Appositional bone reconstruction with xenogenous graft associated with bone marrow mononuclear cell fraction in rabbits calvaria

Oliveira, Rafael de Mello e [UNIFESP] January 2014 (has links) (PDF)
Submitted by Maria Anália Conceição (marianaliaconceicao@gmail.com) on 2016-06-23T14:07:32Z No. of bitstreams: 1 Publico-NOVO-06.pdf: 3014625 bytes, checksum: 7a5c61cc40f9cd02772425bc1b416a0d (MD5) / Approved for entry into archive by Maria Anália Conceição (marianaliaconceicao@gmail.com) on 2016-06-23T14:14:50Z (GMT) No. of bitstreams: 1 Publico-NOVO-06.pdf: 3014625 bytes, checksum: 7a5c61cc40f9cd02772425bc1b416a0d (MD5) / Made available in DSpace on 2016-06-23T14:14:50Z (GMT). No. of bitstreams: 1 Publico-NOVO-06.pdf: 3014625 bytes, checksum: 7a5c61cc40f9cd02772425bc1b416a0d (MD5) Previous issue date: 2014 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Introdução: A manutenção das características estruturais do tecido ósseo é almejada quando substitutos ósseos são utilizados em procedimentos de enxertia aposicional. Dentro deste escopo, a utilização da fração de células mononucleares da medula óssea visa incrementar os resultados da enxertia óssea com o aumento do contato entre osso e titânio. Objetivo: Avaliar a associação da fração de células mononucleares da medula óssea com enxerto ósseo xenógeno em reconstrução aposicional na calvária de coelhos. Métodos: Doze coelhos da raça Nova Zelândia foram distribuídos, randomicamente, em dois grupos, Grupo Controle (n=6 - substituto ósseo xenógeno) e Grupo Experimental (n=6 - substituto ósseo xenógeno enriquecido com a fração de células mononucleares da medula óssea). Foi criado um modelo de regeneração óssea guiada por meio de dois cilindros instalados na calvária de cada um dos animais. A eutanásia ocorreu após oito semanas sendo analisado: (1) mensuração do volume tecidual formado no interior dos cilindros e (2) Histomorfometria dos parâmetros: Tecido Mineralizado Não Vital (TMNV); Tecido Mineralizado Vital (TMV); Tecido Não Mineralizado (TNM) e Contato Tecido Mineralizado Vital - Titânio (CTMVT). Resultados: As mensurações do volume tecidual formado no interior dos cilindros dos grupos Controle e Experimental demostraram manutenção do volume não havendo diferença entre os grupos. A histomorfometria não demonstrou diferença para os parâmetros TMNV, TMV havendo diferença para o parâmetro CTMVT. Conclusão: A associação do enxerto xenógeno com a fração de células mononucleares da medula óssea, em modelo de regeneração óssea guiada, aumenta a área de contato do tecido mineralizado vital com o titânio. / Purpose: This study investigated the combination of a bone marrow mononuclear fraction with a bone xenograft material in an appositional bone regeneration technique. Methods: Twelve New Zealand rabbits were randomly divided into two groups of six animals. Bone reconstruction situations were created using titanium cylinders filled with xenograft in Control group and xenograft enriched with the bone marrow mononuclear fraction in Experimental group. Two cylinders were adapted onto the calvaria of each animal. The bone marrow aspirate was obtained from the tibia of every animal. After 8 weeks, the animals were sacrificed and their parietal bone fixed in 10% formalin for analysis: (1) clinical measurement of the bone volume formed inside the cylinders and (2) histomorphometric evaluation of parameters such as vital mineralized tissue (VMT), non-vital mineralized tissue (NVMT), non-mineralized tissue (NMT) and vital mineralized tissue in contact with titanium (VMTCT). Results: The clinical measurements of groups 1 and 2 demonstrated a bone volume gain of 88.36+25.97% and 98.96+0.00%, respectively. Histomorphometry demonstrated a VMT of 18.96+9.00% and 28.02+8.76%; NVMT of 28.43+2.44% and 25.57+2.33%; NMT of 52.61+10.80% and 46.42+10.06%; VMTCT of 4.98+4.30% and 27.29+9.58%, respectively. Conclusion: The results from this study suggest that the use of the bone marrow mononuclear fraction can improve bone healing and the level of osseointegration.
135

Utilização sistêmica de estrôncio não radioativo como potencializador da formação óssea em ratos /

Scardueli, Cássio Rocha. January 2018 (has links)
Orientador: Elcio Marcantonio Junior / Resumo: O uso de medicamentos a base de estrôncio tem se tornado notável na prevenção e tratamento de enfermidades relacionadas ao tecido ósseo. Essa notabilidade se dá devido a sua ação conjunta em células distintas e envolvidas na neoformação óssea, osteoblastos e osteoclastos. Devido a seus resultados positivos o estrôncio passou a ser utilizado também como coadjuvante de processos de neoformação óssea, principalmente procedimentos cirúrgicos maxilo-faciais. Sendo assim, este estudo teve como objetivos a avaliação de diferentes compostos, e dosagens a base de estrôncio em procedimentos de osseointegração, enxertia óssea. Para tal, os resultados foram distribuídos em 4 artigos para melhor compreensão. No estudo 1, revisão de literatura, foram analisados estudos que utilizaram estrôncio sistêmico como terapia para processos de osseointegração e enxertia óssea em animais. No estudo 2, osseointegração, foram analisadas diferentes dosagens de ranelato de estrôncio (50 e 625mg), e carbonato/cloreto de estrôncio (30 e 365 mg), administrados sistemicamente, durante o processo de osseointegração. Semelhantemente, o estudo 3 analisou a influência dos mesmos compostos a base de estrôncio em defeitos críticos ósseos em calvarias. E por ultimo, no estudo 4, uma análise relacionada a toxicidade do suplemento foi realizada nas dosagens que obtiveram melhores resultados. Como resultados, os estudos 2 e 3 apresentaram resultados semelhantes e positivos para os suplementos a base de estrôncio nas m... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The use of strontium medications has become notable in prevention and treatment of bone tissue related diseases. This notability is related to double action in distinct cells involved in bone neoformation, osteoblasts and osteoclasts. Due to its positive results, strontium has also been used as a coadjuvant of bone neoformation processes, mainly maxillofacial surgical procedures. Thus, this study had as objectives the evaluation of different compounds, and dosages based on strontium in procedures of osseointegration and bone grafting. For this, the results were distributed in 4 studies for better understanding. In study 1, literature review, we analyzed studies that used systemic strontium as a therapy for osseointegration processes and bone grafting in animals. In study 2, osseointegration, different dosages of strontium ranelate (50 and 625mg), and strontium carbonate/strontium chloride (30 and 365mg), systemically administered during the osseointegration process, were analyzed. Similarly, study 3 analyzed the influence of the same strontium-based compounds on critical bone defects in calvarias. Finally, in study 4, an analysis related to toxicity of the supplement was performed at the dosages that obtained the best results. As results, studies 2 and 3 presented similar and positive results for the strontiumbased supplements at the highest concentrations (strontium ranelate 625 mg and strontium carbonate / 365 mg strontium). Considering these dosages, study 4 showed the abs... (Complete abstract click electronic access below) / Doutor
136

Efeitos in vitro da fotofuncionalização da superfície do titânio usando luz UVC

Pacheco, Viviane Neves January 2017 (has links)
A união estrutural entre o tecido ósseo e a superfície do implante é definida como osseointegração. O sucesso deste processo depende tanto de fatores relacionados à característica física do implante, bem como de fatores sistêmicos e biológicos responsáveis pela formação e manutenção do tecido perimplantar. O processo de osseointegração pode ser comprometido por inúmeros fatores de risco: fumo, baixa qualidade e quantidade de tecido ósseo e morbidades sistêmicas, como o diabetes. Contudo, mesmo em condições excelentes, por vezes, não há a formação de tecido ósseo em plenitude ao redor da superfície implantar. A falha na osseointegração pode ocorrer precoce ou tardiamente ocasionando a perda do implante. A fotofuncionalização por irradiação de luz ultravioleta (UV) tem sido reportada recentemente como um método capaz de modificar a superfície do titânio e aumentar sua capacidade osteocondutora. A irradiação com luz ultravioleta (UV) tem sido proposta como método para reverter o processo de envelhecimento do titânio. Contudo a intensidade, tempo de exposição e comprimento de onda que proporcionam os melhores resultados ainda não foram esclarecidos. Objetivo: O objetivo deste estudo foi avaliar os efeitos da fotocatálise por luz UVC sobre o envelhecimento do titânio e analisar alterações de estrutura e de capacidade biológica in vitro do titânio irradiado em diferentes tempos de exposição. Metodologia: Foi desenvolvida uma câmara para fotofuncionalização de titânio com características distintas das apresentadas no mercado. A amostra foi composta por discos de titânio irradiados em diferentes tempos de exposição à luz ultravioleta (0, 15, 30, 60 minutos). Os discos foram testados quanto à molhabilidade de superfície (ângulo de contato com água), a topografia (microscopia eletrônica de varredura- MEV) e composição química (espectroscopia de fotoelétrons excitados por raio-x – XPS), adesão celular (cultura celular e MEV) e viabilidade por SRB. Resultados: O tratamento por luz UVC promoveu alterações nas características de superfície do titânio, como aumento da molhabilidade e remoção de hidrocarbonetos da superfície após 15 minutos de exposição na câmara desenvolvida. As características biológicas do material também parecem ter sofrido alterações, com melhora na capacidade de adesão e viabilidade. Conclusões: A fotofuncionalização do titânio provou ser eficaz para o tratamento de superfícies envelhecidas neste estudo, com significativas modificações na estrutura química superficial e na capacidade biológica do material. / The structural union between the bone tissue and the implant surface is defined as osseointegration. The success of this process depends both on factors related to the physical characteristics of the implant, as well as the systemic and biological factors responsible for the formation and maintenance of perimplant tissue. The process of osseointegration can be compromised by numerous risk factors: smoking, poor quality and quantity of bone tissue and systemic morbidities, such as diabetes. However, even in excellent conditions, sometimes there is no formation of bone tissue in fullness around the implant surface. Failure to osseointegration may occur early or late leading to implant loss. Photofunctionalisation by ultraviolet (UV) light irradiation has recently been reported as a method capable of modifying the titanium surface and increasing its osteoconductive capacity. Ultraviolet (UV) irradiation has been proposed as a method to reverse the aging process of titanium. However the intensity, time of exposure and wavelength that provide the best results have not yet been clarified. The Aim: of this study was to evaluate the effects of photocatalysis by UVC light on aging of titanium and to analyze changes in structure and in vitro biological capacity of irradiated titanium at different exposure times. Methodology: A titanium photofunctioning chamber has been developed with characteristics different from those presented in the market. The sample was composed of titanium disks irradiated in different times of exposure to ultraviolet light (0, 15, 30, 60 minutes). The discs were tested for surface wettability (water contact angle), topography (SEM-scanning electron microscopy) and chemical composition (x-ray excitation photoelectron spectroscopy), cell adhesion (cell culture and SEM) and viability by SRB. Results: UVC treatment promoted changes in titanium surface characteristics, such as increased wettability and removal of hydrocarbons from the surface after 15 minutes of exposure in the developed chamber. The biological characteristics of the material also appear to have changed, with improved adhesion and viability. Conclusions: Photofunctional titanium has proved to be effective for the treatment of surfaces aged in this study, with significant modifications in the surface chemical structure and biological capacity of the material.
137

Análise da influência da morfologia porosa de implantes de titânio no processo de crescimento ósseo

Moreira, Anderson Camargo January 2013 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-graduação em Ciências e Engenharia de Materiais, Florianópolis, 2013. / Made available in DSpace on 2014-08-06T17:13:20Z (GMT). No. of bitstreams: 1 321931.pdf: 10691516 bytes, checksum: bc7e3518f2b190bc8afed68069d5d8dd (MD5) Previous issue date: 2013 / O tecido ósseo está sempre suscetível a lesões, causadas por agentes externos ou patologias, onde em alguns casos a intervenção cirúrgica para instalação de implantes se faz necessária. Dentre os biomateriais utilizados como sustentação para a regeneração óssea, os implantes porosos processados a base de titânio apresentam uma combinação de fatores que viabilizam o seu emprego, entre eles, apropriadas propriedades químicas e mecânicas. Além da biocompatibilidade, a caracterização estrutural desses materiais é de relevante importância, pois suas características morfológicas também influenciam o processo de regeneração óssea. Este projeto tem como objetivo principal a caracterização de dois grupos de implantes de titânio com morfologias porosas distintas, além da avaliação do crescimento ósseo em suas fases porosas, uma vez que as amostras foram implantadas em tecidos ósseos de coelhos. As análises estruturais e de quantificação óssea foram realizadas por meio da análise de imagens tridimensionais adquiridas com a microtomografia de raios X. As amostras foram processadas por meio da técnica da metalurgia do pó, usando Titânio puro grau 1 como matéria prima e bicarbonato de amônio como agente gerador de poros. Diferentes granulometrias e proporções dos pós utilizados asseguraram diferenças morfológicas entre os dois grupos de implantes. As amostras foram implantadas em tíbias de coelhos, onde os períodos de permanência no tecido ósseo de 7, 14, 21, 28 e 35 dias foram respeitados para a avaliação do processo osseointegrativo. Foram analisados os parâmetros estruturais de porosidade, tamanho de poros e conexões, número de coordenação, permeabilidade, área superficial e grau de esfericidade dos poros de cada grupo. As correlações investigadas entre a fração de poros ocupada por osso e os parâmetros físicos indicaram a influência da morfologia porosa no processo de reparação óssea. Os resultados encontrados contribuirão para a otimização de biomateriais porosos direcionando o seu processamento para atingir propriedades que melhorem o desempenho dos implantes <br> / Bone tissue is susceptible to injuries induced by pathologies or accidents. In some cases, a surgical intervention to implant devices is necessary. Biomaterials are often used as scaffolds to bone recuperation. To be applied as a scaffold, porous titanium implants are a good choice due to their chemical and mechanical properties. Besides the biocompatibility, biomaterial implants must to offer other structural parameters which permit the bone ingrowth process. In this work, two groups of porous titanium implants were processed by powder metallurgy with distinct pore morphology. Pure titanium and ammonium bicarbonate (as pore former) were used in the samples processing. Different quantities and grain sizes of the powders provided different pore morphology for the groups. The implants were introduced into rabbits bone tissues for 7, 14, 21, 28 and 35 days. Therefore, the aim of this work is to characterize the pore phase of the titanium porous implants, and also to quantify the pore fraction occupied by neo-bone formation. The measurements were accomplished by means of X-ray microtomography image analysis. Structural parameters such as porosity, pore size, throat size, interconnectivity, permeability, surface area and pore sphericity were analyzed. The correlations between bone neoformation data and structural parameters indicate the influence of the pore shape on osseointegration process. The results of this work can be useful to improve the porous biomaterial processing.
138

Regeneração óssea vertical usando barreira não-porosa de politetrafluoretileno em implantes osteointegrados inseridos parcialmente na tíbia de coelhos

Macedo, Nelson Luiz de [UNESP] 11 June 1999 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:24:48Z (GMT). No. of bitstreams: 0 Previous issue date: 1999-06-11. Added 1 bitstream(s) on 2015-12-10T14:30:56Z : No. of bitstreams: 1 000135628.pdf: 4737621 bytes, checksum: 65372fad0f2424a027b424684796f0c6 (MD5) / O objetivo deste estudo foi avaliar a possibilidade de obter regeneração óssea dirigida utilizando-se uma barreira fisica não-porosa de PTFE em implantes osteointegrados, parcialmente inseridos na tíbia de coelhos, e as característícas da interface entre implantes de titânio, revestidos ou não com plasma de titânio, e o tecido ósseo regenerado. Vinte implantes Screw-Vent foram instalados nas tíbias direita e esquerda, emergindo 3,0 mm do topo da crista óssea, criando um defeito ósseo horizontal. No lado experimental, os implantes e o tecido ósseo adjacente foram cobertos com uma barreira não-porosa de PTFE. A análise histológica mostrou que todos os implantes estavam em contato direto com o tecido ósseo. As medidas histológicas mostraram um ganho ósseo médio em altura de 2,15 mm e 2,42 mm nos defeitos com barreira, e de 1,95 mm e 0,43 mm nos controles com revestimento de plasma de titânio e com tratamento ácido da superficie, respectivamente. Os resultados sugeriram que a colocação de implantes emergindo 3,0 mm do defeito ósseo pode resultar em crescimento ósseo vertical e que o osso regenerado foi capaz de osteointegrar os implantes. A utilização da barreira parece ser crítica quando se utiliza o implante de titânio com a superficie tratada por ácido / The purpose of this study was to evaluate the possibility to obtaining guided bone regeneration utilizing a nonporous PTFE barrier in the osseointegrated implants, protruding from the bone level of the rabbit tíbia. The histologic characteristics of the interface between titanium implants, one group titanium-plasma coated, another group with acid-treated surfaces and the regenerated bone were also studied Twenty Screw-Vent implants were placed in tibias of five rabbits, two at the right side and two at the left side, protruding 3 mm from the bone level, to create a horizontal bone defect. ln the experimental side, the implants and adjacent bone were protected with a nonporous PTFE barrier. Histologic analysis after three months showed that all implants were in direct contact with the bane. Histologic measurements showed an average gain in bone height of the 2.15 and 2.42 mm for the barrier group and 1.95 and 0.43 mm for the control defects, in the titanium plasma-spray and acid-treated implant surfaces, respectively. The results suggest that the placement of implants protruding 3 mm from crestal bone defects may result in vertical bone augmentation and the regenerated bone is able to osseointegrate implants. lt seems to be critical the use of the PTFE barrier when acid-treated surface implants are inserted
139

Avaliação da osseointegração promovida por implantes jateados por Al2O3: análises histológica e histométrica em cães

Ponzoni, Daniela [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2004Bitstream added on 2014-06-13T19:41:00Z : No. of bitstreams: 1 ponzoni_d_dr_araca.pdf: 781446 bytes, checksum: 6716157527edd6e5ca653e94715b65fd (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A formação de uma interface osseointegrada é mais previsível quando osso denso e saudável está em contato com a superfície do implante no momento da instalação. Porém, a colocação de implantes imediatos após exodontia apresenta inúmeras vantagens, entre elas a preservação da arquitetura óssea e gengival dos processos alveolares, além da diminuição do tempo cirúrgico. A utilização de uma superfície modificada proporciona um maior contato ósseo com o implante; baseado em princípios biológicos. A proposta deste trabalho é avaliar qualitativa e quantitativamente a interface entre osso e os implantes de titânio, jateados por Al2O3 instalados imediatamente após exodontias, em cães. Os implantes foram instalados nos alvéolos de pré-molares mandibulares bilateralmente em quatro cães. Foram instalados quatro implantes para cada animal (4mm de diâmetro e 10mm de comprimento) do Sistema Colosso (Emfils®), sendo dois de cada lado da mandíbula. Os animais foram sacrificados aos 120 dias pós-operatórios. As peças foram desmineralizadas, e os implantes removidos. Três implantes foram perdidos, três fibrointegrados e dez osseointegrados. A análise quantitativa foi realizada considerando-se cinco roscas apicais e o fundo do implante. A análise histológica mostrou tecido ósseo saudável em fase de maturação em íntimo contato com os implantes osseointegrados. Na análise histométrica, observou-se um contato ósseo de 76% nos implantes osseointegrados. / An osseointegrated interface could be predictable when dense and healthy bone is in contact with the titanium implant surface at the moment of implant insertion. However, immediate implantation after exodontia presents numerous advantages, among them, maintenance of bone and gingival architecture and decrease of operative time. The use of an implant with modified surface favors bone contact, according to biological principles. This study aims to evaluate the interface between bone and Al2O3 blasted titanium implants installed in 4 dogs immediately after bilateral exodontias of mandibular premolars. Four Emfils® implants (Sistema Colosso - 4mm diameter; 10mm length), 2 per side, were used in each dog. Animals were sacrificed after 120 days of surgery and the samples removed. Bone was decalcified and the implants removed. Three implants were lost, 3 had fibrointegration and 10 osseointegrated. Histological analysis showed a healthy tissue in process of maturation interfacing osseointegrated implants. Quantitative analysis was focused in 5 apical threads and the bottom of the implants. It was shown a contact of 76% between bone and the implants. Osseointegration was achieved around Al2O3 blasted titanium implants installed immediately after exodontias.
140

Análises biomecânica e histológica da interface de implantes osseointegrados submetidos à carga mastigatória imediata em mandíbulas de cães

Lenharo, Ariel [UNESP] 03 November 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-11-03Bitstream added on 2014-06-13T19:22:06Z : No. of bitstreams: 1 lenharo_a_dr_araca_prot.pdf: 1956702 bytes, checksum: 5122f32b3aab14c8107085fded1a11c7 (MD5) / O objetivo deste trabalho foi de estudar em mandíbula de cães, os implantes osseointegrados submetidos a carga imediata considerando a qualidade óssea formada na interface implante-osso, como também medir o contato ósseo da referida interface. Foram utilizados quatro cães que, após as exodontias, receberam três implantes Osseotite 3,75 x 8,5 (Implant Innovations Incorporation) e, após os procedimentos de moldagem e de laboratório para a confecção da prótese em Níquel-Cromo, estas foram instaladas no mesmo dia da instalação dos implantes e submetidas a técnica da carga imediata. Após 240 dias, os implantes mesial e distal foram contra-torqueados medindo-se a resistência do tecido ósseo neoformado. Na seqüência, os animais foram sacrificados (240 dias) e as peças foram processadas para cortes histológicos sem descalcificação. As lâminas obtidas foram coradas pelo azul de toluidina e pelo picro-sirius que foram analisadas pelos microscópios óptico e de luz polarizada, respectivamente. Nas lâminas coradas pelo azul de toluidina, foi possível observar o tecido ósseo neoformado em contato com a superfície dos implantes com ósteons bem definidos. Nestas lâminas foram medidos os perímetros dos implantes para determinar o contato ósseo. As lâminas coradas pelo picro-sirius mostraram deposição de colágeno tipo I. A média de contato ósseo foi de 77,5% e o teste de contratorque aplicado nos implantes apresentou média de 76,13 Ncm. Considerando as limitações deste trabalho, foi possível concluir que a carga imediata em segmentos parcialmente desdentados é uma técnica viável para reabilitação bucal. / The objective of this work was to study the osseointegrated implants undergone immediately loading in dog mandibles, considering the bone quality formed in the implant-bone interface as well as bone contact. Four dogs were used, which after exodontics, received three Osseotite implants 3.75 x 8.5 (Implant Innovations Incorporation) and after the full-arch impression with custom tray and laboratorial procedures for the fabrication of the prosthesis in nickel chrome, this one were installed in the same day as the installation of the implants and was undergone a immediately loading. After 240 days, the mesial and distal implants were reverse torqued, measuring like this, the resistance of the neoformed osseous tissue. Soon after, the animals were sacrificed (240 days) and the samples were processed for histological examination by means of undescalcified sections without decalcification. The histologic specimens attained were stained with toluidine blue and with Picrus Sirius. After microscopical examination of the sections stained by toluidine blue with the optical microscope, it was possible to observe the neoformed osseous tissue and with the presence of well defined osteons. The histologic specimens stained with Picrus Sirius were analysed by polarized light microscope and they showed type I collagen deposition. The mean of osseous contact was of 77.5% between the implant and the bone, and the biomechanical test by means of reverse-torque presented a mean of 76.13 Ncm. Considering the limitations of this work it was possible to conclude that the immediately loading in partially edentulous segments is a viable technique for oral rehabilitation.

Page generated in 0.0916 seconds