• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 25
  • Tagged with
  • 25
  • 14
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação do tecido ósseo perimplantar através de técnicas radiográficas convencional e digitais

Cavalcanti de Abreu, Taciana January 2003 (has links)
Made available in DSpace on 2014-06-12T23:00:25Z (GMT). No. of bitstreams: 2 arquivo8523_1.pdf: 966776 bytes, checksum: 1f6dee000ca6f5abb903ac7a64f7b9da (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2003 / O presente estudo examinou 48 regiões perimplantares de 12 implantes dentários de pacientes que procuraram um serviço especializado. Os pacientes foram radiografados imediatamente após a instalação dos implantes, 15 dias e 3 meses após a sua colocação e 3 meses após Todas as radiografias foram realizadas de maneira padronizada. Quatro sítios foram avaliados em cada implante, dois na mesial e dois distal, sendo um na cervical e outro longo do implante, em cada um dos lados. As seguintes análises radiográficas foram realizadas: análise visual convencional no negatoscópio e análises digitais utilizando os programas Photoshop 6.0 (Adobe Systems Incorporated, Mountain View, California, USA) (análise quantitativa dos níveis de cinza) e o ImageTool 2.0 (University of Texas Health Science Center, San Antonio, Texas, USA) (subtração digital). Com base na metodologia empregada e nos resultados encontrados foi possível concluir que: a) o tempo utilizado não foram suficientes para demonstrar a presença de osteointegração em torno dos implantes dentários; b) as técnicas de análise digitais não puderam detectar osteointegração em menor tempo, quando comparadas à técnica subjetiva de análise visual convencional, nos períodos de tempo avaliados; c) os fenômenos de reabsorção óssea predominaram, principalmente na região cervical do implante; d) a avaliação no negatoscópio e a subtração digital demonstraram que os processos de reabsorção óssea predominam na região cervical do implante, 3 meses após a colocação dos mesmos, enquanto a mensuração dos NC não demonstrou diferença nos resultados obtidos nos dois tempos cirúrgicos avaliados; e) os fenômenos de reabsorção foram mais evidentes na mandíbula, e os de neoformação óssea na maxila; f) a mensuração dos NC com ponto de corte 5 comportou-se diferentemente da mesma análise com ponto de corte 10, assim como a análise no negatoscópio e a subtração digital, e a subtração digital e a mensuração dos NC com ponto de corte de 5; g) em relação aos testes de diagnóstico, a avaliação no negatoscópio, tendo-se como padrão-ouro a análise dos NC, com ponto de corte 5 ou 10, foi a que apresentou maior acurácia; e os piores resultados ocorreram quando o negatoscópio foi considerado o padrão-ouro em relação aos demais
2

Estudo da influência das dimensões dos grânulos de hidroxiapatita na integração óssea / not available

Moreira, Adriana dos Santos Barone 24 March 2000 (has links)
Este estudo teve como finalidade analisar experimentalmente a aplicação de diferentes tamanhos de grânulos de hidroxiapatita em falhas ósseas produzidas em ambos os fêmures de ratos machos da raça Wistar e investigar as correlações dos tamanhos dos grânulos com a quantidade de tecido ósseo neoformado. Cada falha óssea foi preenchida com um dos três tamanhos de grânulos de hidroxiapatita utilizados neste estudo (212 &#956, 500&#956 e 1000&#956). Os animais foram divididos em 3 grupos experimentais compostos por 15 animais cada, sendo que cada grupo foi sacrificado de acordo com a data do sacrifício: 30, 90 e 180 dias de período de pós-operatório, respectivamente e posteriormente submetidos ao estudo histológico. No terceiro grupo experimental, foi também realizado estudo radiológico no período de pós-operatório imediato, aos 30, 90 e 180 dias. O grupo controle, composto por 10 animais, que não tiveram preenchimento de suas falhas ósseas , foram submetidos aos estudos histológico e radiológico nos mesmos períodos que o terceiro grupo experimental. De acordo com os resultados dos estudos radiológico e histológico, concluiu-se que a hidroxiapatita empregada foi biocompatível, no entanto, atrasou o processo de reparação óssea na falha, enquanto que o grupo controle apresentou os melhores resultados, com completa reorganização da falha óssea com apenas 90 dias de período de pós-operatório. / This study evaluated the hydroxyapatite granules osteointegration in defects produced on both femurs of Wistar rats. The defects were filled with one of the three different sizes of hydroxyapatite granules (212&#956, 500&#956 and 1000&#956). The rats were divided in 3 groups of 15 animals, which were sacrificed at 30, 90 and 180 days after the operation, followed by histological study of the femurs and radiological study ofthe latter group. The control group, of 10 animals, had no fllling of it\'s defects and had radiological study and were sacrificed at 180 days after the operation, followed by histological study. It concludes from radiological and histological studies that all sizes of hydroxyapatite granules applied were biocompatible, although it delayed the bone repair. In this study the bone restoration was better observed on the control group.
3

Estudo da influência das dimensões dos grânulos de hidroxiapatita na integração óssea / not available

Adriana dos Santos Barone Moreira 24 March 2000 (has links)
Este estudo teve como finalidade analisar experimentalmente a aplicação de diferentes tamanhos de grânulos de hidroxiapatita em falhas ósseas produzidas em ambos os fêmures de ratos machos da raça Wistar e investigar as correlações dos tamanhos dos grânulos com a quantidade de tecido ósseo neoformado. Cada falha óssea foi preenchida com um dos três tamanhos de grânulos de hidroxiapatita utilizados neste estudo (212 &#956, 500&#956 e 1000&#956). Os animais foram divididos em 3 grupos experimentais compostos por 15 animais cada, sendo que cada grupo foi sacrificado de acordo com a data do sacrifício: 30, 90 e 180 dias de período de pós-operatório, respectivamente e posteriormente submetidos ao estudo histológico. No terceiro grupo experimental, foi também realizado estudo radiológico no período de pós-operatório imediato, aos 30, 90 e 180 dias. O grupo controle, composto por 10 animais, que não tiveram preenchimento de suas falhas ósseas , foram submetidos aos estudos histológico e radiológico nos mesmos períodos que o terceiro grupo experimental. De acordo com os resultados dos estudos radiológico e histológico, concluiu-se que a hidroxiapatita empregada foi biocompatível, no entanto, atrasou o processo de reparação óssea na falha, enquanto que o grupo controle apresentou os melhores resultados, com completa reorganização da falha óssea com apenas 90 dias de período de pós-operatório. / This study evaluated the hydroxyapatite granules osteointegration in defects produced on both femurs of Wistar rats. The defects were filled with one of the three different sizes of hydroxyapatite granules (212&#956, 500&#956 and 1000&#956). The rats were divided in 3 groups of 15 animals, which were sacrificed at 30, 90 and 180 days after the operation, followed by histological study of the femurs and radiological study ofthe latter group. The control group, of 10 animals, had no fllling of it\'s defects and had radiological study and were sacrificed at 180 days after the operation, followed by histological study. It concludes from radiological and histological studies that all sizes of hydroxyapatite granules applied were biocompatible, although it delayed the bone repair. In this study the bone restoration was better observed on the control group.
4

Biocompatibilidade e osteointegração de células osteoblásticas em contato com nióbio / Biocompatibility and osteointegration of osteoblastic cells in contact with niobium

Molin, Paulo Henrique 29 January 2016 (has links)
O nióbio possui potencial para ser um metal de grande aplicabilidade, tanto na engenharia como na área médica; porém a literatura médica a respeito deste material é escassa. Para que o nióbio de pureza 97,47% possa ser utilizado como material de implante e permita a osteointegração se faz necessário avaliá-lo quanto a sua biocompatibilidade e potencial de mineralização. Para tanto é importante compreender os eventos celulares e moleculares que ocorrem na interface nióbio-célula. Neste estudo foram utilizadas as técnicas laboratoriais de Alamar Blue, coloração de Alizarin Red, assim como a expressão de genes, importantes na ocorrência de mineralização e manutenção das células osteoblásticas, utilizando a técnica de qPCR. As células em contato direto com o nióbio obtiveram atividade celular indiferente em relação ao material controle. O nióbio possibilita a aposição de depósitos de cálcio e a adesão celular em sua superfície, comprovando a osteoindução, osteocondução e osteogênese. A análise do qPCR comprovou estatisticamente pelo método Livak que o nióbio é um material com potencial de osteointegração. O entendimento dos resultados obtidos nos testes de biocompatibilidade, mineralização e expressão gênica comprovaram que o metal nióbio é biocompatível e possui propriedades osteointegrativas, pode ser indicado como um material para implante e que permite a osteointegração. / Niobium has the potential to be a metal with wide applicability in engineering and in the medical field; but the medical literature regarding the behavior of this material is scarce. It is required to evaluate the biocompatibility and mineralization of the niobium (94,47% purity) if it would be used as an implant material and osteointegrate material. Therefore, it is important to understand the cellular and molecular events that occur in the material-cell interface. In this study we used laboratory techniques of Alamar Blue, Alizarin Red staining, as well as gene expression of important genes in the mineralization and maintenance of osteoblastic cells by qPCR technique. The cells in direct contact with the niobium obtained indifferent cellular activity compared to the control material. Niobium allowed affixing calcium deposits and cell adhesion on its surface, proving its osteoinductive, osteoconductive and osteogenesis properties. The qPCR analysis proved statistically by Livak method that niobium is a material with osseointegration potential. An understanding of the biocompatibility, mineralization and gene expression led us to conclusion that the niobium metal is biocompatible and with osteointegrative properties which can be indicated as an implant material that allows osteointegration.
5

Avaliação da densidade ótica peri-implantar cervical em controle longitudinal de implantes na região anterior de maxila / Evaluation of cervical peri-implant optic density in longitudinal control of implants in the anterior maxilla region

Silva, Renan Lucio Berbel da 06 April 2018 (has links)
As complicações peri-implantares, posteriormente a colocação do implante em função, são frequentes e sua identificação precoce pode significar uma terapêutica adequada e consequentemente garantir o sucesso do terapêutica. A proposta neste trabalho foi avaliar longitudinalmente a densidade ótica do osso alveolar peri-implantar na região cervical, analisada, por meio da técnica de subtração radiográfica de um acervo de radiografias digitais adquiridas de pacientes previamente reabilitados com trinta e sete implantes osteointegrados imediatos na região anterior da maxila. Os controles radiográficos foram realizados em cinco momentos: na instalação das próteses, após 15,90,180 e 360 dias, e as radiografias intrabucais foram obtidas pela técnica do paralelismo de cilindro longo, com posicionadores do tipo Hanshin individualizados de forma a garantir a padronização das imagens. As imagens digitais obtidas foram alinhadas e equalizadas e por fim submetidas ao procedimento de subtração radiográfica. Os resultados indicaram que a metodologia de subtração radiográfica é válida para a avaliação da perda óssea peri-implantar, assim como demonstra a literatura. No entanto, a reprodução das angulações verticais e horizontais, apresentam-se como críticas na avaliação da densidade óptica da crista óssea e demandam grande habilidade do operador para a correta aplicação. Por meio dessa técnica, conseguimos avaliar de forma quantitativa e qualitativa as alterações na faces proximais nas imagens radiográficas do acervo analisado. A subtração radiográfica, por meio da ferramenta de histograma, permitiu quantificar de forma objetiva as diferenças encontradas nas análises. / The peri-implant complications, in addition to implant placement in function, are frequent and their early identification could mean a therapy appropriately and consequently guarantee the success of the treatment. The aim of this research was to longitudinally evaluate of the optical density of the peri-implant alveolar bone at the cervical region, analyzed by means of the radiographic subtraction technique, a collection of digital radiographs acquired from patients previously rehabilitated with thirty seven osseointegrated implants. The radiographic controls performed in five moments, at the installation of the prostheses, after 15,90,180 and 360 days, and the intraoral radiographs were obtained by parallelism technique, with Hanshin-type positioners individualized in order to guarantee the standardization of the images. The obtained digital images were aligned and equalized and finally submitted to radiographic subtraction procedure. The results indicated that the methodology of radiographic subtraction is valid for an evaluation of the peri-implant bone loss, as well as to demonstrated at the literature. However, the reproduction of the vertical and horizontal angles, are presented as critical in the evaluation of the optical density, and demand a great ability of the operator for a correct application. Through the technique we obtained a quantitative and qualitative evaluation in the area of proximal images in the radiographic images of the analyzed data. The histogram tool applied on the radiographic subtraction images allowed to quantify objectively as the differences found in the analyzes.
6

Viabilidade das matrizes de colágeno derivadas do pericárdio e da serosa de intestino bovino no reparo de defeitos cranianos em ratas ovariectomizadas / Viability of collagen matrices derived from bovine intestine pericardium and serous repair in cranial defects in ovariectomized rats

Hirata, Helton Hiroshi 13 December 2013 (has links)
O desenvolvimento e aperfeiçoamento de biomateriais têm aumentado consideravelmente, devido às limitações clínicas do uso do enxerto ósseo autólogo em casos de reparo de graves lesões ósseas. Porém, as condições de saúde do tecido ósseo podem influenciar na capacidade osteogênica desses implantes como nos casos de osteoporose provocada por deficiência hormonal. Objetivos: O presente trabalho avaliou a capacidade osteogênica de matrizes de colágeno aniônicas derivadas do pericárdio bovino e da serosa do intestino bovino, quando implantadas em lesões cranianas de ratas ovariectomizadas. Material e Métodos: Foram utilizadas 30 ratas (Rattus norvegicus, Wistar), com aproximadamente, 12 semanas de idade e peso médio de 300 gramas. Os animais foram submetidos ao procedimento cirúrgico com a finalidade de criação de um defeito na calota craniana. As ratas foram distribuídas em grupo controle (não ovariectomizados) e grupo ovariectomizado. Cada grupo foi dividido em 3 subgrupos, sendo que um deles teve as falhas não preenchidas com biomateriais e os outros 2 subgrupos receberam as matrizes de colágeno de pericárdio bovino e da serosa de intestino bovino, respectivamente. O sacrifício dos animais ocorreu 8 semanas pós-cirúrgico da calota craniana. Em seguida, as amostras foram fotodocumentadas, radiografadas e submetidas aos procedimentos histotécnicos de rotina para a confecção das lâminas histológicas. A pesquisa foi aprovada pelo Comitê de Ética da Faculdade de Medicina de Jundiaí, protocolo nº 301/12. Resultados: As análises macroscópica, radiológica e microscópica demonstraram a biocompatibilidade das matrizes de colágeno implantadas. Histologicamente, observou-se que nas ratas não ovariectomizadas, houve discreta neoformação óssea na área cirúrgica preenchida com as matrizes sendo ainda menor nas ratas ovariectomizadas. O volume de osso formado com defeito, nos grupos não ovariectomizados, foi 7,83±1,32, 21,33±1,96, 22,83±0,98, sendo estatisticamente maiores ao comparar com os valores dos grupos ovariectomizados que foram 3,16±0,75, 16,83±0,98 e 16,16±0,75. Conclusões: As matrizes de colágeno utilizadas foram biocompatíveis com o tecido ósseo receptor, porém com baixa capacidade osteogênica, não ocorrendo sua osteointegração. Nos animais ovariectomizados, ficou ainda mais acentuado o comprometimento do reparo ósseo. / The development and improvement of biomaterials have increased considerably due to the limitations of the clinical use of autologous bone graft in cases of serious repair bone injuries. However the health of the bone can influence the osteogenic capacity of these implants as in osteoporosis caused by hormone deficiency. Objectives: This study evaluated the osteogenic capacity of anionic collagen sponges derived from the bovine pericardium and serous bovine intestine when implanted in head injuries of ovariectomized rats. Material and Methods: We used 30 female rats (Rattus norvegicus, Wistar), with approximately 12 weeks of age and weighing 300 grams. The animals underwent the surgical procedure for the purpose of creating a defect in the skull. The rats were divided into control group (non-ovariectomized) and ovariectomized group. Each group was divided into 3 subgroups, one of which had not filled the gaps with biomaterials and the other two subgroups received the collagen sponges bovine pericardium and serous bovine intestine, respectively. The animals were sacrificed 8 weeks after surgery of the skull. Then the samples were photo documented, radiographed and submitted to routine histotechnical procedures for the preparation of histological slides. The study was approved by the Ethics Committee of the Faculty of Medicine of Jundiaí, protocol number 301/12. Results: The macroscopic, microscopic and radiological demonstrated the biocompatibility of collagen sponges implanted. Histologically, it was observed that the non-ovariectomized rats, there was a slight new bone formation at the surgical site filled with mothers being even lower in ovariectomized rats. The volume of bone formed defective, non-ovariectomized groups groups was 7.83±1:32, 21:33±1.96, 22.83±0.98, being statistically higher when compared with the values of ovariectomized animals that were 3.16±0.75, 16.83±0.98 and 0.75±16:16. Conclusions: Collagen sponges were biocompatible with bone tissue receptor, but with lower osteogenic capacity, not its osseointegration occurring. In ovariectomized animals, became even more pronounced impairment of bone repair.
7

Interface osso-implante dental de titânio produzida por cirurgia piezoelétrica / Bone/implant titanium dental interface produced by Piezoelectric Surgery

Kfouri, Flávio de Ávila [UNIFESP] 27 July 2011 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:50:23Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-07-27 / INTRODUÇÃO: Para o sucesso da osteointegração, injúrias e traumas, causadas ao tecido ósseo, são preocupações clínicas quando da instalação de implantes de titânio. Normalmente realizados por fresas, podem gerar calor excessivo e necrose. Com o surgimento da técnica piezoelétrica, procurou-se verificar se a mesma seria menos lesiva aos tecidos adjacentes. OBJETIVO: Avaliar a remodelação óssea da interface osso-implante, produzida por ultrassom em tíbias de coelhos, comparando-a a técnica tradicional. MÉTODO: Noventa e seis implantes foram instalados e acompanhados por 7, 14 e 28 dias por histomorfometria. Analisou-se espessura, número e separação trabecular, volume e área óssea ao redor do implante por um software específico. RESULTADOS: O volume ósseo foi similar pelos dois métodos, com tendência de elevação pela técnica piezoelétrica aos 28 dias. Houve redução da espessura das trabéculas em ambos os métodos, com posterior retorno aos níveis normais. O número de trabéculas elevou-se após 14 dias, sendo mantido posteriormente constante. No método Piezoelétrico observou-se estabilidade na área de contato; no convencional, que iniciou em nível inferior, não se verificou diferença ao final do processo. CONCLUSÃO: A cirurgia piezoelétrica foi eficaz na produção de alvéolos ósseos para integração de implantes dentais de titânio, podendo ser considerada alternativa viável para utilização clínica na implantodontia, visto que não apresentou áreas de necrose óssea e os resultados foram similares à técnica tradicional. / INTRODUCTION: Regarding the success of osseointegration, injuries and traumas caused to bone tissues during the placement of titanium implants are clinical concerns. Drills commonly used in the procedures may generate excessive heat, leading to necrosis. The new piezoelectric technique was tested to determine whether it is less damaging to the surrounding tissues. OBJECTIVE: To evaluate bone remodelling at the interface bone-implant using ultrasound in rabbit tibiae, and compare with results using conventional technique. METHODS: Ninety-six implants were installed and assessed on postoperative days (PO) 7, 14, and 28 by histomorphometry. Trabecular thickness, number, and separation, and area and volume of periimplant bone were measured using specific software. RESULTS: Bone volume was similar for both techniques, with a trend toward an increase for the piezoelectric technique on PO 28. Reduction in trabecular thickness was observed in both methods, but then returning to normal values. Trabecular number increased up to PO 14, and remained constant afterwards. The contact area remained constant for the piezoelectric technique at the 3 time points; for the conventional technique, it was small at first, but showed no difference in values between techniques on PO 28. CONCLUSION: The piezoelectric technique induced bone formation for osseointegration of titanium implants, was not associated with occurrence of bone necrosis, and provided results similar to those using the conventional technique. Therefore, the piezoelectric ultrasound technique can be considered a viable alternative for clinical use in implantology. / TEDE / BV UNIFESP: Teses e dissertações
8

Viabilidade das matrizes de colágeno derivadas do pericárdio e da serosa de intestino bovino no reparo de defeitos cranianos em ratas ovariectomizadas / Viability of collagen matrices derived from bovine intestine pericardium and serous repair in cranial defects in ovariectomized rats

Helton Hiroshi Hirata 13 December 2013 (has links)
O desenvolvimento e aperfeiçoamento de biomateriais têm aumentado consideravelmente, devido às limitações clínicas do uso do enxerto ósseo autólogo em casos de reparo de graves lesões ósseas. Porém, as condições de saúde do tecido ósseo podem influenciar na capacidade osteogênica desses implantes como nos casos de osteoporose provocada por deficiência hormonal. Objetivos: O presente trabalho avaliou a capacidade osteogênica de matrizes de colágeno aniônicas derivadas do pericárdio bovino e da serosa do intestino bovino, quando implantadas em lesões cranianas de ratas ovariectomizadas. Material e Métodos: Foram utilizadas 30 ratas (Rattus norvegicus, Wistar), com aproximadamente, 12 semanas de idade e peso médio de 300 gramas. Os animais foram submetidos ao procedimento cirúrgico com a finalidade de criação de um defeito na calota craniana. As ratas foram distribuídas em grupo controle (não ovariectomizados) e grupo ovariectomizado. Cada grupo foi dividido em 3 subgrupos, sendo que um deles teve as falhas não preenchidas com biomateriais e os outros 2 subgrupos receberam as matrizes de colágeno de pericárdio bovino e da serosa de intestino bovino, respectivamente. O sacrifício dos animais ocorreu 8 semanas pós-cirúrgico da calota craniana. Em seguida, as amostras foram fotodocumentadas, radiografadas e submetidas aos procedimentos histotécnicos de rotina para a confecção das lâminas histológicas. A pesquisa foi aprovada pelo Comitê de Ética da Faculdade de Medicina de Jundiaí, protocolo nº 301/12. Resultados: As análises macroscópica, radiológica e microscópica demonstraram a biocompatibilidade das matrizes de colágeno implantadas. Histologicamente, observou-se que nas ratas não ovariectomizadas, houve discreta neoformação óssea na área cirúrgica preenchida com as matrizes sendo ainda menor nas ratas ovariectomizadas. O volume de osso formado com defeito, nos grupos não ovariectomizados, foi 7,83±1,32, 21,33±1,96, 22,83±0,98, sendo estatisticamente maiores ao comparar com os valores dos grupos ovariectomizados que foram 3,16±0,75, 16,83±0,98 e 16,16±0,75. Conclusões: As matrizes de colágeno utilizadas foram biocompatíveis com o tecido ósseo receptor, porém com baixa capacidade osteogênica, não ocorrendo sua osteointegração. Nos animais ovariectomizados, ficou ainda mais acentuado o comprometimento do reparo ósseo. / The development and improvement of biomaterials have increased considerably due to the limitations of the clinical use of autologous bone graft in cases of serious repair bone injuries. However the health of the bone can influence the osteogenic capacity of these implants as in osteoporosis caused by hormone deficiency. Objectives: This study evaluated the osteogenic capacity of anionic collagen sponges derived from the bovine pericardium and serous bovine intestine when implanted in head injuries of ovariectomized rats. Material and Methods: We used 30 female rats (Rattus norvegicus, Wistar), with approximately 12 weeks of age and weighing 300 grams. The animals underwent the surgical procedure for the purpose of creating a defect in the skull. The rats were divided into control group (non-ovariectomized) and ovariectomized group. Each group was divided into 3 subgroups, one of which had not filled the gaps with biomaterials and the other two subgroups received the collagen sponges bovine pericardium and serous bovine intestine, respectively. The animals were sacrificed 8 weeks after surgery of the skull. Then the samples were photo documented, radiographed and submitted to routine histotechnical procedures for the preparation of histological slides. The study was approved by the Ethics Committee of the Faculty of Medicine of Jundiaí, protocol number 301/12. Results: The macroscopic, microscopic and radiological demonstrated the biocompatibility of collagen sponges implanted. Histologically, it was observed that the non-ovariectomized rats, there was a slight new bone formation at the surgical site filled with mothers being even lower in ovariectomized rats. The volume of bone formed defective, non-ovariectomized groups groups was 7.83±1:32, 21:33±1.96, 22.83±0.98, being statistically higher when compared with the values of ovariectomized animals that were 3.16±0.75, 16.83±0.98 and 0.75±16:16. Conclusions: Collagen sponges were biocompatible with bone tissue receptor, but with lower osteogenic capacity, not its osseointegration occurring. In ovariectomized animals, became even more pronounced impairment of bone repair.
9

Avaliação da densidade ótica peri-implantar cervical em controle longitudinal de implantes na região anterior de maxila / Evaluation of cervical peri-implant optic density in longitudinal control of implants in the anterior maxilla region

Renan Lucio Berbel da Silva 06 April 2018 (has links)
As complicações peri-implantares, posteriormente a colocação do implante em função, são frequentes e sua identificação precoce pode significar uma terapêutica adequada e consequentemente garantir o sucesso do terapêutica. A proposta neste trabalho foi avaliar longitudinalmente a densidade ótica do osso alveolar peri-implantar na região cervical, analisada, por meio da técnica de subtração radiográfica de um acervo de radiografias digitais adquiridas de pacientes previamente reabilitados com trinta e sete implantes osteointegrados imediatos na região anterior da maxila. Os controles radiográficos foram realizados em cinco momentos: na instalação das próteses, após 15,90,180 e 360 dias, e as radiografias intrabucais foram obtidas pela técnica do paralelismo de cilindro longo, com posicionadores do tipo Hanshin individualizados de forma a garantir a padronização das imagens. As imagens digitais obtidas foram alinhadas e equalizadas e por fim submetidas ao procedimento de subtração radiográfica. Os resultados indicaram que a metodologia de subtração radiográfica é válida para a avaliação da perda óssea peri-implantar, assim como demonstra a literatura. No entanto, a reprodução das angulações verticais e horizontais, apresentam-se como críticas na avaliação da densidade óptica da crista óssea e demandam grande habilidade do operador para a correta aplicação. Por meio dessa técnica, conseguimos avaliar de forma quantitativa e qualitativa as alterações na faces proximais nas imagens radiográficas do acervo analisado. A subtração radiográfica, por meio da ferramenta de histograma, permitiu quantificar de forma objetiva as diferenças encontradas nas análises. / The peri-implant complications, in addition to implant placement in function, are frequent and their early identification could mean a therapy appropriately and consequently guarantee the success of the treatment. The aim of this research was to longitudinally evaluate of the optical density of the peri-implant alveolar bone at the cervical region, analyzed by means of the radiographic subtraction technique, a collection of digital radiographs acquired from patients previously rehabilitated with thirty seven osseointegrated implants. The radiographic controls performed in five moments, at the installation of the prostheses, after 15,90,180 and 360 days, and the intraoral radiographs were obtained by parallelism technique, with Hanshin-type positioners individualized in order to guarantee the standardization of the images. The obtained digital images were aligned and equalized and finally submitted to radiographic subtraction procedure. The results indicated that the methodology of radiographic subtraction is valid for an evaluation of the peri-implant bone loss, as well as to demonstrated at the literature. However, the reproduction of the vertical and horizontal angles, are presented as critical in the evaluation of the optical density, and demand a great ability of the operator for a correct application. Through the technique we obtained a quantitative and qualitative evaluation in the area of proximal images in the radiographic images of the analyzed data. The histogram tool applied on the radiographic subtraction images allowed to quantify objectively as the differences found in the analyzes.
10

Biocompatibilidade e osteointegração de células osteoblásticas em contato com nióbio / Biocompatibility and osteointegration of osteoblastic cells in contact with niobium

Paulo Henrique Molin 29 January 2016 (has links)
O nióbio possui potencial para ser um metal de grande aplicabilidade, tanto na engenharia como na área médica; porém a literatura médica a respeito deste material é escassa. Para que o nióbio de pureza 97,47% possa ser utilizado como material de implante e permita a osteointegração se faz necessário avaliá-lo quanto a sua biocompatibilidade e potencial de mineralização. Para tanto é importante compreender os eventos celulares e moleculares que ocorrem na interface nióbio-célula. Neste estudo foram utilizadas as técnicas laboratoriais de Alamar Blue, coloração de Alizarin Red, assim como a expressão de genes, importantes na ocorrência de mineralização e manutenção das células osteoblásticas, utilizando a técnica de qPCR. As células em contato direto com o nióbio obtiveram atividade celular indiferente em relação ao material controle. O nióbio possibilita a aposição de depósitos de cálcio e a adesão celular em sua superfície, comprovando a osteoindução, osteocondução e osteogênese. A análise do qPCR comprovou estatisticamente pelo método Livak que o nióbio é um material com potencial de osteointegração. O entendimento dos resultados obtidos nos testes de biocompatibilidade, mineralização e expressão gênica comprovaram que o metal nióbio é biocompatível e possui propriedades osteointegrativas, pode ser indicado como um material para implante e que permite a osteointegração. / Niobium has the potential to be a metal with wide applicability in engineering and in the medical field; but the medical literature regarding the behavior of this material is scarce. It is required to evaluate the biocompatibility and mineralization of the niobium (94,47% purity) if it would be used as an implant material and osteointegrate material. Therefore, it is important to understand the cellular and molecular events that occur in the material-cell interface. In this study we used laboratory techniques of Alamar Blue, Alizarin Red staining, as well as gene expression of important genes in the mineralization and maintenance of osteoblastic cells by qPCR technique. The cells in direct contact with the niobium obtained indifferent cellular activity compared to the control material. Niobium allowed affixing calcium deposits and cell adhesion on its surface, proving its osteoinductive, osteoconductive and osteogenesis properties. The qPCR analysis proved statistically by Livak method that niobium is a material with osseointegration potential. An understanding of the biocompatibility, mineralization and gene expression led us to conclusion that the niobium metal is biocompatible and with osteointegrative properties which can be indicated as an implant material that allows osteointegration.

Page generated in 0.0705 seconds