• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • Tagged with
  • 14
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da cauterização completa da luz tubária com diferentes potências de eletrocoagulação bipolar para esterilização feminina

Campagnolo, Marcelo Ivo January 2012 (has links)
A esterilização feminina é uma forma segura e efetiva de contracepção permanente e sua aceitação teve rápido crescimento entre as pacientes, sendo hoje, em todo o mundo, o método anticoncepcional mais popular . Existem várias técnicas e diferentes vias de acesso para o procedimento. Nos dias atuais, a primeira escolha recai sobre a ligadura tubária (LT) por laparoscopia e a técnica de eletrocoagulação bipolar da porção istmica das trompas é a mais utilizada e considerada a mais segura. O objetivo do emprego da eletrocirurgia para LT é evitar destruições teciduais extensas e aplicar a mínima energia eficaz para ocorrer a oclusão tubária, reduzindo as chances de eventos adversos. Dentro desses princípios, houve uma evolução importante com o advento dos sistemas bipolares, de tal modo que a coagulação unipolar teve seu espaço muito reduzido na esterilização devido às taxas altas de complicações, especialmente as maiores, como as queimaduras intestinais. O acúmulo de conhecimento atual não permite conclusões definitivas acerca da potência mínima necessária para produzir uma eletrocoagulação bipolar eficiente na trompa humana. A ausência de recomendações tanto por parte de fabricantes de equipamentos eletrocirúrgicos como de especialistas sobre a melhor potência de coagulação bipolar para produzir uma coagulação tubária satisfatória justifica um estudo para estabelecer uma rotina baseada em evidências sobre uma wattagem que ofereça segurança durante a cirurgia laparoscópica para ligadura tubária. O objetivo do artigo foi verificar a potência mínima necessária para cauterização tubária completa utilizando coagulação bipolar por meio de uma análise histológica padronizada de dano térmico em espécimes de tuba uterina humanos submetidos a potências crescentes, simulando uma esterilização. Com isto, pretendeu-se contribuir para estabelecer um padrão para a realização da ligadura tubária laparoscópica. Neste estudo, verificamos que potências de 25, 30, 35 e 40W no modo coagulação foram capazes de produzir cauterização tubária completa em número semelhante. A avaliação visual de dessecação sem tempo definido se relacionou com coagulação satisfatória tanto quanto o tempo determinado de 5 segundos. Nossos resultados devem de ser vistos com cautela por representarem situação experimental realizada fora do corpo do paciente. / Female sterilization is a safe and effective form of permanent contraception that quickly gained acceptance among women and is now the most popular contraceptive method worldwide. Several techniques and approaches are available for this procedure. Currently, the method of choice is laparoscopic tubal ligation (TL), with bipolar electrocoagulation of the tubal isthmus being the most widely used and apparently safest technique. A core tenet of electrosurgical TL is to avoid extensive tissue damage and use the least power setting required for tubal occlusion, thus reducing the odds of adverse events. According to these principles, the advent of bipolar electrocoagulation systems represented a major advancement and monopolar cauterization has lost much of its popularity for sterilization due to high rates of complications, particularly major ones such as bowel burns. Hence, the current state of knowledge precludes any definitive conclusions as to the minimum power required for effective bipolar electrocoagulation of the human fallopian tube. Neither even electrosurgical equipment manufacturers nor experts in the field provide any recommendations on the optimal bipolar electrocoagulation power setting for satisfactory tubal obliteration. We believe this justifies research with the objective of establishing an evidence-based, standard wattage level that provides safety and efficacy during laparoscopic TL. The objective was to ascertain the minimum power setting required for complete tubal cauterization with bipolar electrocoagulation, by means of a standardized histological analysis of thermal injury in human fallopian tube specimens subjected to advancing power settings, simulating sterilization. The intention was to contribute to the establishment of a standard technique for laparoscopic TL. In the present study, power settings of 25, 30, 35 and 40 W in coagulation mode produced complete tubal cauterization in a similar number of cases. Visual assessment of desiccation with no set coagulation period was as associated with satisfactory tubal cauterization as the use of a set coagulation period of 5 seconds. These results should be viewed cautiously, as they represent the findings of an experimental ex vivo study.
2

Avaliação da cauterização completa da luz tubária com diferentes potências de eletrocoagulação bipolar para esterilização feminina

Campagnolo, Marcelo Ivo January 2012 (has links)
A esterilização feminina é uma forma segura e efetiva de contracepção permanente e sua aceitação teve rápido crescimento entre as pacientes, sendo hoje, em todo o mundo, o método anticoncepcional mais popular . Existem várias técnicas e diferentes vias de acesso para o procedimento. Nos dias atuais, a primeira escolha recai sobre a ligadura tubária (LT) por laparoscopia e a técnica de eletrocoagulação bipolar da porção istmica das trompas é a mais utilizada e considerada a mais segura. O objetivo do emprego da eletrocirurgia para LT é evitar destruições teciduais extensas e aplicar a mínima energia eficaz para ocorrer a oclusão tubária, reduzindo as chances de eventos adversos. Dentro desses princípios, houve uma evolução importante com o advento dos sistemas bipolares, de tal modo que a coagulação unipolar teve seu espaço muito reduzido na esterilização devido às taxas altas de complicações, especialmente as maiores, como as queimaduras intestinais. O acúmulo de conhecimento atual não permite conclusões definitivas acerca da potência mínima necessária para produzir uma eletrocoagulação bipolar eficiente na trompa humana. A ausência de recomendações tanto por parte de fabricantes de equipamentos eletrocirúrgicos como de especialistas sobre a melhor potência de coagulação bipolar para produzir uma coagulação tubária satisfatória justifica um estudo para estabelecer uma rotina baseada em evidências sobre uma wattagem que ofereça segurança durante a cirurgia laparoscópica para ligadura tubária. O objetivo do artigo foi verificar a potência mínima necessária para cauterização tubária completa utilizando coagulação bipolar por meio de uma análise histológica padronizada de dano térmico em espécimes de tuba uterina humanos submetidos a potências crescentes, simulando uma esterilização. Com isto, pretendeu-se contribuir para estabelecer um padrão para a realização da ligadura tubária laparoscópica. Neste estudo, verificamos que potências de 25, 30, 35 e 40W no modo coagulação foram capazes de produzir cauterização tubária completa em número semelhante. A avaliação visual de dessecação sem tempo definido se relacionou com coagulação satisfatória tanto quanto o tempo determinado de 5 segundos. Nossos resultados devem de ser vistos com cautela por representarem situação experimental realizada fora do corpo do paciente. / Female sterilization is a safe and effective form of permanent contraception that quickly gained acceptance among women and is now the most popular contraceptive method worldwide. Several techniques and approaches are available for this procedure. Currently, the method of choice is laparoscopic tubal ligation (TL), with bipolar electrocoagulation of the tubal isthmus being the most widely used and apparently safest technique. A core tenet of electrosurgical TL is to avoid extensive tissue damage and use the least power setting required for tubal occlusion, thus reducing the odds of adverse events. According to these principles, the advent of bipolar electrocoagulation systems represented a major advancement and monopolar cauterization has lost much of its popularity for sterilization due to high rates of complications, particularly major ones such as bowel burns. Hence, the current state of knowledge precludes any definitive conclusions as to the minimum power required for effective bipolar electrocoagulation of the human fallopian tube. Neither even electrosurgical equipment manufacturers nor experts in the field provide any recommendations on the optimal bipolar electrocoagulation power setting for satisfactory tubal obliteration. We believe this justifies research with the objective of establishing an evidence-based, standard wattage level that provides safety and efficacy during laparoscopic TL. The objective was to ascertain the minimum power setting required for complete tubal cauterization with bipolar electrocoagulation, by means of a standardized histological analysis of thermal injury in human fallopian tube specimens subjected to advancing power settings, simulating sterilization. The intention was to contribute to the establishment of a standard technique for laparoscopic TL. In the present study, power settings of 25, 30, 35 and 40 W in coagulation mode produced complete tubal cauterization in a similar number of cases. Visual assessment of desiccation with no set coagulation period was as associated with satisfactory tubal cauterization as the use of a set coagulation period of 5 seconds. These results should be viewed cautiously, as they represent the findings of an experimental ex vivo study.
3

Avaliação da cauterização completa da luz tubária com diferentes potências de eletrocoagulação bipolar para esterilização feminina

Campagnolo, Marcelo Ivo January 2012 (has links)
A esterilização feminina é uma forma segura e efetiva de contracepção permanente e sua aceitação teve rápido crescimento entre as pacientes, sendo hoje, em todo o mundo, o método anticoncepcional mais popular . Existem várias técnicas e diferentes vias de acesso para o procedimento. Nos dias atuais, a primeira escolha recai sobre a ligadura tubária (LT) por laparoscopia e a técnica de eletrocoagulação bipolar da porção istmica das trompas é a mais utilizada e considerada a mais segura. O objetivo do emprego da eletrocirurgia para LT é evitar destruições teciduais extensas e aplicar a mínima energia eficaz para ocorrer a oclusão tubária, reduzindo as chances de eventos adversos. Dentro desses princípios, houve uma evolução importante com o advento dos sistemas bipolares, de tal modo que a coagulação unipolar teve seu espaço muito reduzido na esterilização devido às taxas altas de complicações, especialmente as maiores, como as queimaduras intestinais. O acúmulo de conhecimento atual não permite conclusões definitivas acerca da potência mínima necessária para produzir uma eletrocoagulação bipolar eficiente na trompa humana. A ausência de recomendações tanto por parte de fabricantes de equipamentos eletrocirúrgicos como de especialistas sobre a melhor potência de coagulação bipolar para produzir uma coagulação tubária satisfatória justifica um estudo para estabelecer uma rotina baseada em evidências sobre uma wattagem que ofereça segurança durante a cirurgia laparoscópica para ligadura tubária. O objetivo do artigo foi verificar a potência mínima necessária para cauterização tubária completa utilizando coagulação bipolar por meio de uma análise histológica padronizada de dano térmico em espécimes de tuba uterina humanos submetidos a potências crescentes, simulando uma esterilização. Com isto, pretendeu-se contribuir para estabelecer um padrão para a realização da ligadura tubária laparoscópica. Neste estudo, verificamos que potências de 25, 30, 35 e 40W no modo coagulação foram capazes de produzir cauterização tubária completa em número semelhante. A avaliação visual de dessecação sem tempo definido se relacionou com coagulação satisfatória tanto quanto o tempo determinado de 5 segundos. Nossos resultados devem de ser vistos com cautela por representarem situação experimental realizada fora do corpo do paciente. / Female sterilization is a safe and effective form of permanent contraception that quickly gained acceptance among women and is now the most popular contraceptive method worldwide. Several techniques and approaches are available for this procedure. Currently, the method of choice is laparoscopic tubal ligation (TL), with bipolar electrocoagulation of the tubal isthmus being the most widely used and apparently safest technique. A core tenet of electrosurgical TL is to avoid extensive tissue damage and use the least power setting required for tubal occlusion, thus reducing the odds of adverse events. According to these principles, the advent of bipolar electrocoagulation systems represented a major advancement and monopolar cauterization has lost much of its popularity for sterilization due to high rates of complications, particularly major ones such as bowel burns. Hence, the current state of knowledge precludes any definitive conclusions as to the minimum power required for effective bipolar electrocoagulation of the human fallopian tube. Neither even electrosurgical equipment manufacturers nor experts in the field provide any recommendations on the optimal bipolar electrocoagulation power setting for satisfactory tubal obliteration. We believe this justifies research with the objective of establishing an evidence-based, standard wattage level that provides safety and efficacy during laparoscopic TL. The objective was to ascertain the minimum power setting required for complete tubal cauterization with bipolar electrocoagulation, by means of a standardized histological analysis of thermal injury in human fallopian tube specimens subjected to advancing power settings, simulating sterilization. The intention was to contribute to the establishment of a standard technique for laparoscopic TL. In the present study, power settings of 25, 30, 35 and 40 W in coagulation mode produced complete tubal cauterization in a similar number of cases. Visual assessment of desiccation with no set coagulation period was as associated with satisfactory tubal cauterization as the use of a set coagulation period of 5 seconds. These results should be viewed cautiously, as they represent the findings of an experimental ex vivo study.
4

Esplenectomia em cães: comparação entre os acessos laparoscópico e convencional

Stedile, Rafael January 2007 (has links)
Nos últimos anos, a utilização da laparoscopia em Medicina Veterinária vem expandindo, e consequentemente a necessidade de pesquisas que determinem as vantagens, desvantagens e possíveis complicações de cada procedimento. O presente estudo tem como objetivo descrever uma técnica de esplenectomia laparoscópica, assim como as alterações decorrentes deste acesso, e compará-la ao procedimento convencional em cães. Foram utilizadas 15 cadelas hígidas, sem raça definida, com peso médio de 17,4 ±2,5kg. Os animais foram distribuídos em três grupos: grupo I - acesso convencional (por laparotomia) utilizando ligadura com ácido poliglicólico no selamento vascular do hilo esplênico, grupo II - acesso convencional (por laparotomia) com eletrocoagulador bipolar do hilo esplênico, e grupo III - acesso laparoscópico com eletrocoagulador bipolar para selamento vascular dos ramos esplênicos. Estes grupos foram avaliados em relação ao tempo cirúrgico, à perda de sangue, ao tamanho das incisões e às complicações durante e após a cirurgia. Também foram comparadas as avaliações da escala de dor e as alterações no leucograma e nas concentrações séricas da alanina aminotransferase (ALT), da fosfatase alcalina (FA), da creatina quinase (CK), da proteína C-reativa (PCR), da glicose e do cortisol no pós-operatório. Os acessos convencionais não diferiram entre si nos parâmetros avaliados. O acesso laparoscópico apresentou diferenças significativas (p<0,05) quando comparado ao convencional: maior tempo cirúrgico, menor acesso abdominal, diminuição na perda de sangue, menores concentrações de PCR, maiores níveis de CK e FA, além de pontução menor na escala de dor. A cirurgia laparoscópica apresentou menor número de complicações das feridas cirúrgicas. A ALT, cortisol, glicemia, leucograma, temperatura retal, freqüência cardíaca e freqüência respiratória pós-operatórias não diferiram significativamente entre os acessos convencional e laparoscópico. Conclui-se que a cirurgia laparoscópica é viável para esplenectomia em cães, apresentando vantagem em relação à perda de sangue, ao estresse cirúrgico e às feridas cirúrgicas, embora apresente maior tempo cirúrgico e cause aumento transitório de enzimas hepáticas e muscular. / In the last years, the use of laparoscopy in Veterinary Medicine have been expanded, and consequently the need of studies that establish advantage, disadvantage and possible complications of each procedure. The purpose of the current study is to describe a laparoscopic splenectomy technique, as well as their alterations due to this access, and to compare this to the open procedure in dogs. A total of 15 healthy female mongrel dogs were used, with mean weight 17,4 ±2,5kg. The animals were distributed in three groups: group I - conventional access (for laparotomy) using double ligation of the vessels with poliglicolic acid in the vascular sealing of the splenic hilus, group II - conventional access (for laparotomy) with bipolar electrocoagulation of the splenic hilus, and group III - laparoscopic access with bipolar electrocoagulation for vascular sealing of the splenic branches. These groups were evaluated in relation to: operative time, blood loss, size of the incisions, complications during and after the surgery. It also were compared the pain scores and the white blood cells (WBC) and the postoperative serum concentrations of the alanine aminotransferase (ALT), alkaline phosphatase (ALP), creatine kinase (CK), C-reactive protein (CRP), glucose and cortisol. Conventional accesses did not differ to each other in the evaluate parameters. Laparoscopic access presented significant differences (p <0,05) when compared to the open surgery: longer operative time, smaller abdominal acess, decrease in the blood loss, lower concentrations of CRP, higher levels of CK and ALP, besides lower scores in the pain scale. Laparoscopic surgery presented smaller number of the surgical wounds complications. No significant differences were observed between groups in the postoperative temperature, heart rate, respiratory rate, WBC, ALT, cortisol and glucose concentrations. In conclusion, the laparoscopic technique is viable for splenectomy in dogs, presenting advantage in relation to the blood loss, surgical stress and surgical wounds, however they expend more operative time and cause transitory increase in the liver and muscular enzymes.
5

Interface osso-implante dental de titânio produzida por cirurgia piezoelétrica / Bone/implant titanium dental interface produced by Piezoelectric Surgery

Kfouri, Flávio de Ávila [UNIFESP] 27 July 2011 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:50:23Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-07-27 / INTRODUÇÃO: Para o sucesso da osteointegração, injúrias e traumas, causadas ao tecido ósseo, são preocupações clínicas quando da instalação de implantes de titânio. Normalmente realizados por fresas, podem gerar calor excessivo e necrose. Com o surgimento da técnica piezoelétrica, procurou-se verificar se a mesma seria menos lesiva aos tecidos adjacentes. OBJETIVO: Avaliar a remodelação óssea da interface osso-implante, produzida por ultrassom em tíbias de coelhos, comparando-a a técnica tradicional. MÉTODO: Noventa e seis implantes foram instalados e acompanhados por 7, 14 e 28 dias por histomorfometria. Analisou-se espessura, número e separação trabecular, volume e área óssea ao redor do implante por um software específico. RESULTADOS: O volume ósseo foi similar pelos dois métodos, com tendência de elevação pela técnica piezoelétrica aos 28 dias. Houve redução da espessura das trabéculas em ambos os métodos, com posterior retorno aos níveis normais. O número de trabéculas elevou-se após 14 dias, sendo mantido posteriormente constante. No método Piezoelétrico observou-se estabilidade na área de contato; no convencional, que iniciou em nível inferior, não se verificou diferença ao final do processo. CONCLUSÃO: A cirurgia piezoelétrica foi eficaz na produção de alvéolos ósseos para integração de implantes dentais de titânio, podendo ser considerada alternativa viável para utilização clínica na implantodontia, visto que não apresentou áreas de necrose óssea e os resultados foram similares à técnica tradicional. / INTRODUCTION: Regarding the success of osseointegration, injuries and traumas caused to bone tissues during the placement of titanium implants are clinical concerns. Drills commonly used in the procedures may generate excessive heat, leading to necrosis. The new piezoelectric technique was tested to determine whether it is less damaging to the surrounding tissues. OBJECTIVE: To evaluate bone remodelling at the interface bone-implant using ultrasound in rabbit tibiae, and compare with results using conventional technique. METHODS: Ninety-six implants were installed and assessed on postoperative days (PO) 7, 14, and 28 by histomorphometry. Trabecular thickness, number, and separation, and area and volume of periimplant bone were measured using specific software. RESULTS: Bone volume was similar for both techniques, with a trend toward an increase for the piezoelectric technique on PO 28. Reduction in trabecular thickness was observed in both methods, but then returning to normal values. Trabecular number increased up to PO 14, and remained constant afterwards. The contact area remained constant for the piezoelectric technique at the 3 time points; for the conventional technique, it was small at first, but showed no difference in values between techniques on PO 28. CONCLUSION: The piezoelectric technique induced bone formation for osseointegration of titanium implants, was not associated with occurrence of bone necrosis, and provided results similar to those using the conventional technique. Therefore, the piezoelectric ultrasound technique can be considered a viable alternative for clinical use in implantology. / TEDE / BV UNIFESP: Teses e dissertações
6

Esplenectomia em cães: comparação entre os acessos laparoscópico e convencional

Stedile, Rafael January 2007 (has links)
Nos últimos anos, a utilização da laparoscopia em Medicina Veterinária vem expandindo, e consequentemente a necessidade de pesquisas que determinem as vantagens, desvantagens e possíveis complicações de cada procedimento. O presente estudo tem como objetivo descrever uma técnica de esplenectomia laparoscópica, assim como as alterações decorrentes deste acesso, e compará-la ao procedimento convencional em cães. Foram utilizadas 15 cadelas hígidas, sem raça definida, com peso médio de 17,4 ±2,5kg. Os animais foram distribuídos em três grupos: grupo I - acesso convencional (por laparotomia) utilizando ligadura com ácido poliglicólico no selamento vascular do hilo esplênico, grupo II - acesso convencional (por laparotomia) com eletrocoagulador bipolar do hilo esplênico, e grupo III - acesso laparoscópico com eletrocoagulador bipolar para selamento vascular dos ramos esplênicos. Estes grupos foram avaliados em relação ao tempo cirúrgico, à perda de sangue, ao tamanho das incisões e às complicações durante e após a cirurgia. Também foram comparadas as avaliações da escala de dor e as alterações no leucograma e nas concentrações séricas da alanina aminotransferase (ALT), da fosfatase alcalina (FA), da creatina quinase (CK), da proteína C-reativa (PCR), da glicose e do cortisol no pós-operatório. Os acessos convencionais não diferiram entre si nos parâmetros avaliados. O acesso laparoscópico apresentou diferenças significativas (p<0,05) quando comparado ao convencional: maior tempo cirúrgico, menor acesso abdominal, diminuição na perda de sangue, menores concentrações de PCR, maiores níveis de CK e FA, além de pontução menor na escala de dor. A cirurgia laparoscópica apresentou menor número de complicações das feridas cirúrgicas. A ALT, cortisol, glicemia, leucograma, temperatura retal, freqüência cardíaca e freqüência respiratória pós-operatórias não diferiram significativamente entre os acessos convencional e laparoscópico. Conclui-se que a cirurgia laparoscópica é viável para esplenectomia em cães, apresentando vantagem em relação à perda de sangue, ao estresse cirúrgico e às feridas cirúrgicas, embora apresente maior tempo cirúrgico e cause aumento transitório de enzimas hepáticas e muscular. / In the last years, the use of laparoscopy in Veterinary Medicine have been expanded, and consequently the need of studies that establish advantage, disadvantage and possible complications of each procedure. The purpose of the current study is to describe a laparoscopic splenectomy technique, as well as their alterations due to this access, and to compare this to the open procedure in dogs. A total of 15 healthy female mongrel dogs were used, with mean weight 17,4 ±2,5kg. The animals were distributed in three groups: group I - conventional access (for laparotomy) using double ligation of the vessels with poliglicolic acid in the vascular sealing of the splenic hilus, group II - conventional access (for laparotomy) with bipolar electrocoagulation of the splenic hilus, and group III - laparoscopic access with bipolar electrocoagulation for vascular sealing of the splenic branches. These groups were evaluated in relation to: operative time, blood loss, size of the incisions, complications during and after the surgery. It also were compared the pain scores and the white blood cells (WBC) and the postoperative serum concentrations of the alanine aminotransferase (ALT), alkaline phosphatase (ALP), creatine kinase (CK), C-reactive protein (CRP), glucose and cortisol. Conventional accesses did not differ to each other in the evaluate parameters. Laparoscopic access presented significant differences (p <0,05) when compared to the open surgery: longer operative time, smaller abdominal acess, decrease in the blood loss, lower concentrations of CRP, higher levels of CK and ALP, besides lower scores in the pain scale. Laparoscopic surgery presented smaller number of the surgical wounds complications. No significant differences were observed between groups in the postoperative temperature, heart rate, respiratory rate, WBC, ALT, cortisol and glucose concentrations. In conclusion, the laparoscopic technique is viable for splenectomy in dogs, presenting advantage in relation to the blood loss, surgical stress and surgical wounds, however they expend more operative time and cause transitory increase in the liver and muscular enzymes.
7

Esplenectomia em cães: comparação entre os acessos laparoscópico e convencional

Stedile, Rafael January 2007 (has links)
Nos últimos anos, a utilização da laparoscopia em Medicina Veterinária vem expandindo, e consequentemente a necessidade de pesquisas que determinem as vantagens, desvantagens e possíveis complicações de cada procedimento. O presente estudo tem como objetivo descrever uma técnica de esplenectomia laparoscópica, assim como as alterações decorrentes deste acesso, e compará-la ao procedimento convencional em cães. Foram utilizadas 15 cadelas hígidas, sem raça definida, com peso médio de 17,4 ±2,5kg. Os animais foram distribuídos em três grupos: grupo I - acesso convencional (por laparotomia) utilizando ligadura com ácido poliglicólico no selamento vascular do hilo esplênico, grupo II - acesso convencional (por laparotomia) com eletrocoagulador bipolar do hilo esplênico, e grupo III - acesso laparoscópico com eletrocoagulador bipolar para selamento vascular dos ramos esplênicos. Estes grupos foram avaliados em relação ao tempo cirúrgico, à perda de sangue, ao tamanho das incisões e às complicações durante e após a cirurgia. Também foram comparadas as avaliações da escala de dor e as alterações no leucograma e nas concentrações séricas da alanina aminotransferase (ALT), da fosfatase alcalina (FA), da creatina quinase (CK), da proteína C-reativa (PCR), da glicose e do cortisol no pós-operatório. Os acessos convencionais não diferiram entre si nos parâmetros avaliados. O acesso laparoscópico apresentou diferenças significativas (p<0,05) quando comparado ao convencional: maior tempo cirúrgico, menor acesso abdominal, diminuição na perda de sangue, menores concentrações de PCR, maiores níveis de CK e FA, além de pontução menor na escala de dor. A cirurgia laparoscópica apresentou menor número de complicações das feridas cirúrgicas. A ALT, cortisol, glicemia, leucograma, temperatura retal, freqüência cardíaca e freqüência respiratória pós-operatórias não diferiram significativamente entre os acessos convencional e laparoscópico. Conclui-se que a cirurgia laparoscópica é viável para esplenectomia em cães, apresentando vantagem em relação à perda de sangue, ao estresse cirúrgico e às feridas cirúrgicas, embora apresente maior tempo cirúrgico e cause aumento transitório de enzimas hepáticas e muscular. / In the last years, the use of laparoscopy in Veterinary Medicine have been expanded, and consequently the need of studies that establish advantage, disadvantage and possible complications of each procedure. The purpose of the current study is to describe a laparoscopic splenectomy technique, as well as their alterations due to this access, and to compare this to the open procedure in dogs. A total of 15 healthy female mongrel dogs were used, with mean weight 17,4 ±2,5kg. The animals were distributed in three groups: group I - conventional access (for laparotomy) using double ligation of the vessels with poliglicolic acid in the vascular sealing of the splenic hilus, group II - conventional access (for laparotomy) with bipolar electrocoagulation of the splenic hilus, and group III - laparoscopic access with bipolar electrocoagulation for vascular sealing of the splenic branches. These groups were evaluated in relation to: operative time, blood loss, size of the incisions, complications during and after the surgery. It also were compared the pain scores and the white blood cells (WBC) and the postoperative serum concentrations of the alanine aminotransferase (ALT), alkaline phosphatase (ALP), creatine kinase (CK), C-reactive protein (CRP), glucose and cortisol. Conventional accesses did not differ to each other in the evaluate parameters. Laparoscopic access presented significant differences (p <0,05) when compared to the open surgery: longer operative time, smaller abdominal acess, decrease in the blood loss, lower concentrations of CRP, higher levels of CK and ALP, besides lower scores in the pain scale. Laparoscopic surgery presented smaller number of the surgical wounds complications. No significant differences were observed between groups in the postoperative temperature, heart rate, respiratory rate, WBC, ALT, cortisol and glucose concentrations. In conclusion, the laparoscopic technique is viable for splenectomy in dogs, presenting advantage in relation to the blood loss, surgical stress and surgical wounds, however they expend more operative time and cause transitory increase in the liver and muscular enzymes.
8

Eletrocauterio na cesarea = complicações na ferida cirurgica / The use of electrocautery in caesarean sections : surgical wound complications

Moreira, Cristiane Menabo 04 May 2010 (has links)
Orientador: Eliana Martorano Amaral / Dissertação (mestrado) - Universidade Estadual de Campinas. Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-15T15:29:14Z (GMT). No. of bitstreams: 1 Moreira_CristianeMenabo_M.pdf: 2436149 bytes, checksum: d5b0e854b0557df822a87c69461aaeee (MD5) Previous issue date: 2010 / Resumo: Objetivo: Avaliar a efetividade e segurança do uso do eletrocautério para coagulação na da ferida operatória da cesárea. Métodos: Foi realizado um ensaio clínico piloto duplo cego controlado aleatorizado. Mulheres com indicação de cesárea, com até uma cesárea prévia, que fizeram pré-natal foram aleatorizadas na hora da cirurgia para uso ou não de eletrocautério para coagulação. As 224 voluntárias que participaram foram examinadas na alta hospitalar (3o dia) e pós-alta, no 7°.ao 10° dia e 30° ao 40° dia. Foram avaliados sinais infecciosos, hematoma, seroma e deiscência. A amostra foi calculada baseada em uma prevalência de infecção pós-alta de 14,4%, estimando-se um risco adicional de 15% para o grupo com uso de eletrocautério, totalizando 224 voluntárias. Os dados foram analizados por intenção de tratamento e a razão de risco foi calculada. Resultados: Os grupos foram similares quanto à demografia, paridade, consultas de pré-natal, índice de massa corporal e cesárea prévia. Durante a internação, apenas 2,8% das mulheres com uso de eletrocautério apresentaram complicações na ferida operatória. As taxas de complicações alcançaram 15,4% no grupo sem cautério, chegando a 23% no outro grupo, 7-10 dias pós-alta (RR=1,50 0,84-2,60). Foram observadas poucas complicações no 30° ao 40°dia e no grupo sem cautério (RR=1,15, 95% IC=0,61-2,16). A cesárea durou 105 e 100 minutos sem e com cautério, respectivamente (p=0,54). Não foi observada nenhuma arritmia cardíaca neonatal. Conclusão: O uso de cautério não se mostrou de maior risco para complicações na ferida operatória de cesárea, sendo necessários mais estudos que deem continuidade e ampliem os conhecimentos em procedimentos realizados em gestantes / Abstract: Purpose: To estimate the risk for wound complications when electrocautery is available for coagulation during cesarean section. Methods: A randomized controlled trial of using electrocautery for coagulation was performed among 224 women with none or one previous cesarean who had their pregnancy terminated with an abdominal delivery. Volunteers who accepted to participate were examined before discharge (3rd day), when the skin suture was removed (7-10 days), and 30-40 days after surgery. Infection signs, haematoma, seroma, and scar dehiscence were searched during visits. Sample size was calculated based on 14.4% prevalence of infection after discharge, estimating 15% added risk for the group using electrocautery, totalizing 224 volunteers. Unadjusted and adjusted prevalence risk (age, schooling, obesity, previous cesarean) were calculated. Results: Both groups were similar regarding demographics, parity, antenatal care, body mass index, and previous cesarean. During hospital stay, none among 96 women without electrocautery, and 2.8% of 97 women using electrocautery showed wound complications. The figures reached 15.4% and 23% respectively after 7-10 days (unadjusted RR = 1.50, 0.84-2.60). Few other complications were observed later, only among the non-intervention group (RR=1.15, 95% CI = 0.61-2.16). The lack of effect was maintained after adjusting for age, schooling, obesity, and previous cesarean (RR=1.47, 0.77-2.81). Surgical procedure lasted 105 and 100 minutes for both groups (p=0.54). No neonatal arrhythmia was observed. Conclusion: There is no evidence to recommend the use of electrocautery for coagulation during cesarean delivery. Wound complications were concentrated on post-discharge period for both groups / Mestrado / Tocoginecologia / Mestre em Tocoginecologia
9

Eletrocirurgia: evidências para o cuidado de enfermagem / Electrosurgery: evidence for the nursing care

Brito, Maria de Fátima Paiva 10 August 2007 (has links)
A eletrocirurgia é uma tecnologia amplamente utilizada nas salas cirúrgicas. O período perioperatório oferece riscos para o paciente desde o momento da sua entrada no bloco operatório até o retorno para a unidade de origem e a eletrocirurgia constitui um destes riscos. A escassez de produção científica relacionada ao uso desta tecnologia nos motivou a elaborar este estudo. A implementação da prática baseada em evidências tem se tornado fundamental para a tomada de decisão do enfermeiro, sendo escolhida como o referencial teórico-metodológico adotado. O presente estudo é uma revisão integrativa da literatura, que teve como objetivo buscar e avaliar as evidências disponíveis na literatura sobre o conhecimento científico já produzido sobre os cuidados de enfermagem relacionados ao uso de eletrocirurgia no período intra-operatório. Para a seleção dos artigos utilizamos as bases de dados Medline e CINAHL, cuja amostra foi de 21 artigos científicos, os quais foram categorizados nas temáticas: complicações decorrentes do uso da eletrocirurgia (5 artigos); complicações decorrentes do uso da eletrocirurgia de alta potência (4 artigos); complicações decorrentes do uso da eletrocirurgia, outros equipamentos elétricos e agentes anti-sépticos (3 artigos); conhecimento dos enfermeiros sobre a unidade de eletrocirurgia (2 artigos) e recomendações práticas para o uso da eletrocirurgia (7 artigos). Os artigos publicados na área da enfermagem abordaram na sua maioria as recomendações práticas para o uso da eletrocirurgia (7 artigos); os relatos de casos (2 artigos) descreveram as queimaduras decorrentes do uso de eletrocirurgia com correntes de alta potência e 2 artigos avaliaram o conhecimento geral dos enfermeiros em eletrocirurgia. Na área médica todos os artigos eram relatos de casos (7 artigos), os quais descreveram as complicações (queimaduras) ocorridas devido a utilização desta tecnologia e as publicações consideradas de outras áreas (3 artigos) abordavam as queimaduras ocorridas no eletrodo dispersivo e em local alternativo. Os resultados deste estudo apontaram que é imperativo para o enfermeiro perioperatório o conhecimento técnico-científico sobre o uso da eletrocirurgia e as evidências encontradas fornecem subsídios para a implementação de políticas e procedimentos que garantam a segurança do paciente minimizando os riscos potenciais no uso desta tecnologia. / The electrosurgery is a technology largely used in surgical rooms. The perioperative period presents risks to patients from the moment they enter the surgical unit until they return to the unit of origin, and the electrosurgery constitutes one of these risks. The lack of scientific production related to the use of this technology motivated us to elaborate this study. The implementation of evidence-based practice has become fundamental to the nurse\'s decision process and was chosen as the theoreticalmethodological referential adopted. The present study is a literature integrative review that aimed to seek and evaluate the evidences available in the literature on the scientific knowledge produced on nursing care related to the use of electrosurgery in the period intra-surgical. For the selection of articles, the databases Medline e CINAHL were used and 21 scientific articles composed the sample, which were categorized in the themes: complications caused by the electrosurgery (five articles); complications caused by the use of high frequency electrosurgery (four articles); complications caused by the use of electrosurgery, other electrical equipments and anti-septic agents (three articles); nurse\'s knowledge about the electrosurgery unit (two articles) and practical recommendations for the use of the electrosurgery (seven articles). The articles published in the area of nursing approached, in their majority, practical recommendations for the use of electrosurgery (seven articles); the case reports (two articles) described burns caused by the use of electrosurgery with high frequency electric current and two articles evaluated nurse\'s general knowledge on electrosurgery. In the medical area all the articles were case reports (seven articles), which described the complications (burns) that occurred due to the use of this technology and the publications considered from other areas (three articles) approached burns that occurred in dispersive electron and in alternative site. The results of this study indicate that it is imperative for the perioperative nurse the technical-scientific knowledge about the use of the electrosurgery. The evidence found supports implementation of policies and procedures that assure the safety of the patient minimizing potential risks in the use of this technology.
10

Conversor ressonante para aplicação biomédica em eletrocirurgia /

Favi, José Lucas Araújo. January 2018 (has links)
Orientador: Carlos Alberto Canesin / Resumo: Neste trabalho, apresentou-se o estudo de um gerador eletrocirúrgico utilizando um conversor ressonante. Com o intuito de realizar procedimentos cirúrgicos, o bisturi elétrico, ou eletrônico, apresenta grandes vantagens ao método clássico do bisturi de aço inoxidável. Para conseguir os efeitos terapêuticos desejados, corte e coagulação, sem que haja qualquer estímulo nervoso, utiliza-se sinal senoidal com alta frequência. Os conversores ressonantes são estruturas chaveadas que operam em elevadas frequências com baixas perdas, logo, alto rendimento. Fez-se, então, um estudo sobre as estruturas inversoras e os filtros ressonantes. A sequência do trabalho trata da análise da estrutura proposta (Full-Bridge – LCLC – ZVS – FM) demonstrando as etapas envolvidas em um ciclo de chaveamento do conversor e o seu equacionamento. A partir de uma metodologia para calcular os parâmetros do filtro, definiram-se os valores das indutâncias e das capacitâncias séries e paralelas. Projetou-se o controlador pormeio de umametodologia que visa o controle pelos valores de pico das formas de onda. Realizaram-se simulações dos modos de operação desejados e observaram-se os valores encontrados da tensão de saída, da corrente de saída, da corrente de entrada e a comutação ZVS para variadas cargas. Implementou-se um protótipo do qual os resultados práticos obtidos são apresentados e discutidos. / Abstract: In this work, a study of an electrosurgical generator was presented using a resonant converter. In order to perform surgical procedures, electric or electronic scalpel presents great advantages to the classic method of the stainless steel scalpel. To achieve the desired therapeutic effects, cutting and coagulation, without any nerve stimulation, sine wave signal is applied with high frequency. Resonant converters are switched structures that operate at high frequencies with low losses, hence, high efficiency. A study was then made about inverter structures and resonant filters. The work sequence was the analysis of the proposed structure (Full-Bridge LCLCZVS- FM) demonstrating the steps involved in a converter switching cycle and its equation. From a methodology to calculate filter parameters, values of series and parallel inductances and capacitances were defined. The controller was designed using a methodology that controls the peak values of the waveforms. Simulations of the desired modes of operation were executed out and the values of output voltage, output current, input current and ZVS switching were observed for various loads. A prototype was implemented and the results obtained are presented and discussed. / Mestre

Page generated in 0.4322 seconds