• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Uso da p-benzoquinona para determinação de proteínas totais em diversas matrizes e amino grupos livres em síntese de peptídeos em fase sólida / Use of p-benzoquinone for assay of total protein in several samples and free amino groups in solid phase peptide synthesis

Zaia, Dimas Augusto Morozin 21 June 1996 (has links)
O presente trabalho apresenta metodologias utilizando a p-benzoquinona (PBQ) para a determinação de proteínas totais em diversas matrizes. As metodologias propostas foram comparadas com os métodos recomendados ou os mais utilizados, conforme o caso. O método aqui proposto, para determinação de proteínas totais em plasma sangüíneo, foi comparado com o método de biureto, mostrando-se adequado e com sensibilidade dez vezes maior que a do biureto. Para a determinação de proteínas totais em diversos tecidos de rato, o método proposto foi comparado com os métodos de Hartree e FFDW, e apresentou resultados mais próximos do FFDW do que o método de Hartree e, também, mostrou ser mais rápido, barato e de fácil realização. O método desenvolvido para determinação de proteínas totais em leite em pó desnatado foi comparado com os métodos de Kjeldahl e Lowry e cols., sendo mais simples e rápido que as metodologias de Lowry e Kjeldahl. Para determinação de amino grupos livres em síntese de peptídeos em fase sólida, a metodologia proposta foi comparada com o método de Kaiser e cols. O método proposto apresentou diversas vantagens sobre o método de Kaiser, sendo estas: o método é sensível a prolina, não precisa preparar nenhuma solução, não apresenta falso positivo para histidina e é rápido. / The present thesis describes the utilization of p-benzoquinone (PBQ) for assay of total protein in several samples. The methods presented here were compared with those mostly used or recommended depending on the case. For determination of total proteins in the blood plasma, the proposed method was compared with biuret method, and it was 10 times more sensitive than biuret method and convenient method for determination of total proteins in plasma. The assay of total proteins in several rat tissues with the proposed method, was compared with Hartree and FFDW methods, and it shows closer proteins content to FFDW method than Hartree method, besides it was faster, less expensive and easier to be used than Hartree method. The method developed for determination of total proteins in skin milk powder, was compared with Kjeldahl and Lowry methods and showed to be more simple and faster than these methods. For determination of free amino groups in solid phase peptide synthesis, the proposed method was compared with Kaiser method. The proposed method showed several advantages than Kaiser method, such as: it is sensitive for proline, it is not necessary to prepare any solution and it does not show a false positive test for histidine.
2

Uso da p-benzoquinona para determinação de proteínas totais em diversas matrizes e amino grupos livres em síntese de peptídeos em fase sólida / Use of p-benzoquinone for assay of total protein in several samples and free amino groups in solid phase peptide synthesis

Dimas Augusto Morozin Zaia 21 June 1996 (has links)
O presente trabalho apresenta metodologias utilizando a p-benzoquinona (PBQ) para a determinação de proteínas totais em diversas matrizes. As metodologias propostas foram comparadas com os métodos recomendados ou os mais utilizados, conforme o caso. O método aqui proposto, para determinação de proteínas totais em plasma sangüíneo, foi comparado com o método de biureto, mostrando-se adequado e com sensibilidade dez vezes maior que a do biureto. Para a determinação de proteínas totais em diversos tecidos de rato, o método proposto foi comparado com os métodos de Hartree e FFDW, e apresentou resultados mais próximos do FFDW do que o método de Hartree e, também, mostrou ser mais rápido, barato e de fácil realização. O método desenvolvido para determinação de proteínas totais em leite em pó desnatado foi comparado com os métodos de Kjeldahl e Lowry e cols., sendo mais simples e rápido que as metodologias de Lowry e Kjeldahl. Para determinação de amino grupos livres em síntese de peptídeos em fase sólida, a metodologia proposta foi comparada com o método de Kaiser e cols. O método proposto apresentou diversas vantagens sobre o método de Kaiser, sendo estas: o método é sensível a prolina, não precisa preparar nenhuma solução, não apresenta falso positivo para histidina e é rápido. / The present thesis describes the utilization of p-benzoquinone (PBQ) for assay of total protein in several samples. The methods presented here were compared with those mostly used or recommended depending on the case. For determination of total proteins in the blood plasma, the proposed method was compared with biuret method, and it was 10 times more sensitive than biuret method and convenient method for determination of total proteins in plasma. The assay of total proteins in several rat tissues with the proposed method, was compared with Hartree and FFDW methods, and it shows closer proteins content to FFDW method than Hartree method, besides it was faster, less expensive and easier to be used than Hartree method. The method developed for determination of total proteins in skin milk powder, was compared with Kjeldahl and Lowry methods and showed to be more simple and faster than these methods. For determination of free amino groups in solid phase peptide synthesis, the proposed method was compared with Kaiser method. The proposed method showed several advantages than Kaiser method, such as: it is sensitive for proline, it is not necessary to prepare any solution and it does not show a false positive test for histidine.
3

Desenvolvimento de um sensor para isoniazida empregando um eletrodo modificado com 2,3-Dicloro-5,6-Diciano-p-Benzoquinona e Grafeno: aplicação em formulações farmacêuticas utilizadas no tratamento da tuberculose / Developement of a novel sensor for isoniazid based on 2,3dichloro-5,6-dicyano-p-benzoquinone and graphene: application in drug samples utilized in the treatment of tuberculosis

Lima, Kayni Cassia Moreira Soares 27 July 2016 (has links)
Submitted by Rosivalda Pereira (mrs.pereira@ufma.br) on 2017-06-02T20:34:02Z No. of bitstreams: 1 KayniLima.pdf: 2329691 bytes, checksum: f4483166f9b35c9a8cce0606f988ddb5 (MD5) / Made available in DSpace on 2017-06-02T20:34:02Z (GMT). No. of bitstreams: 1 KayniLima.pdf: 2329691 bytes, checksum: f4483166f9b35c9a8cce0606f988ddb5 (MD5) Previous issue date: 2016-07-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / The present work describes the development of a novel platform for the electrocatalysis of isoniazid (INH) employing a glassy carbon electrode (GCE) modified with 2,3-dichloro-5,6-dicyano-p-benzoquinone (DDQ) adsorbed on reduced graphene oxide (rGO). The modified electrode (GCE/OGr/DDQ) was covered with a Náfion® film to avoid the leaching out of the composite from electrodic surface. The materials rGO, DDQ and rGO/DDQ were characterized by Fourier transform infrared spectroscopy (FTIR) and the analytical response of the sensor for the analyte was studied by cyclic voltammetry (CV) and amperometry techniques. The sensor showed excellent electrocatalytic activity for INH oxidation with a decrease in the overpotential about 660 mV vs Ag/AgCl and anodic peak current about 4 times higher than the observed response at an electrode unmodified. The increase of the reaction rate for INH was attributed to the efficient electron transfer between the studied specie and immobilized material on the surface of the GCE surface. The number of electrons determined in the INH oxidation process on the modified electrode was equal to 2. Under the optimized operational and experimental conditions, the sensor showed a wide linear range for INH from 0.5 to 380 µmol L-1 for n = 16 (r2 = 0.999); good sensibility and limit of detection equal to 0.42 µA µmol-1 L, and 0.15 µmol L-1, respectively. The proposed sensor was successfully applied for INH determination in drug samples used in the tuberculosis treatment and results obtained in studies of addition and recovery showed that the proposed method has good accuracy with recovery values between 98.46 and 101 % to INH. / O presente trabalho descreve o desenvolvimento de uma nova plataforma para a eletrocatálise de isoniazida (INH) empregando um eletrodo de carbono vítreo (ECV) modificado com 2,3-dicloro-5,6-diciano-p-benzoquinona (DDQ) adsorvido em óxido de grafeno reduzido (OGr). O eletrodo modificado (ECV/OGr/DDQ) foi coberto com um filme de náfion® para evitar o lixiviamento do compósito da superfície eletródica. Os materiais OGr, DDQ e OGr/DDQ foram caracterizados por Espectroscopia no infravermelho com transformada de Fourier (FTIR) e a resposta analítica do sensor para o analito foi estudada através das técnicas voltametria cíclica (CV) e amperometria. O sensor apresentou uma excelente atividade eletrocatalítica para a oxidação de INH com uma diminuição do sobrepotencial cerca de 660 mV vs Ag/AgCl e corrente de pico anódica quatro vezes maior que a resposta observada em um eletrodo não modificado. O aumento na velocidade de reação para a INH foi atribuído à eficiente transferência eletrônica entre a espécie estudada e os materiais imobilizados na superfìcie do ECV. O número de elétrons determinado no processo de oxidação de INH sobre o eletrodo modificado foi igual a 2. Sob as condições experimentais e operacionais otimizadas, o sensor apresentou uma relação linear para a INH de 0,5 à 380 µmol L-1 para n=16 (r2 = 0,999); boa sensibilidade e limite de detecção igual a 0,42 µA µmol-1 L e 0,15 µmol L-1, respectivamente. O sensor proposto foi utilizado com sucesso para a determinação INH em amostras de medicamentos utilizadas no respectivo tratamento da tuberculose e os resultados obtidos nos estudos de adição e recuperação mostraram que o método proposto apresenta boa exatidão com valores de recuperação entre 98,46 e 101% para a INH.

Page generated in 0.0433 seconds