• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 244
  • 80
  • 15
  • 12
  • 8
  • 8
  • 7
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 410
  • 410
  • 237
  • 215
  • 160
  • 105
  • 73
  • 72
  • 70
  • 68
  • 62
  • 57
  • 56
  • 56
  • 53
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
281

Stochastic harmonic emission model of aggregate residential customers

Blanco Castaneda, Ana Maria 10 July 2018 (has links) (PDF)
Harmonic propagation studies of public distribution networks require accurate models of aggregate residential customers (groups of customers) that simulate the harmonic emission of the multitude of household appliances in the network. Most of the present models were developed with the component-based approach, where models of individual household appliances are combined to build the model of multiple customers. This approach requires high amount of input data, like models of individual household appliances and detail information of customer behavior and device composition, which is usually not easy to acquire. However, with the increasing number of PQ-analyzers in the networks, the measurement-based approach is now more and more considered for the modeling of aggregate customers. The measurement-based approach uses measurements of the network in combination with top-down methodologies to obtain models of the aggregate customers. Compared to the component-based approach it has several advantages, like inherent consideration of the real operating changes of the individual household appliances, variation of customer behavior, effect of line impedances, cancellation and attenuation effects, etc. This thesis presents the development of a time-series stochastic model of the low-order harmonic emission of aggregate residential customers based on a top-down measurement-based approach. The model represents the daily variation of the harmonic magnitudes and phase angles. Besides, the model includes the representation of the harmonic unbalances, which is of great importance for the proper analysis of harmonic propagation in medium-voltage networks. The model is parametrized for German networks, but the methodology can be applied to find the models of other regions or countries.
282

Medidor inteligente com uma interface para visualização de parâmetros elétricos e de qualidade de energia com suporte à detecção de origem de faltas / Smart meter with an interface for visualization of electrical and power quality parameters and fault source detection capability

Silva, João Vitor da 27 April 2018 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste trabalho é proposto e apresentado um medidor inteligente de energia elétrica considerando os métodos de medição classe S especificados no PRODIST e na norma IEC 61000-4-30. O medidor proposto calcula os valores eficazes de tensão e corrente, as potências aparente, ativa e reativa, o fator de potência, a frequência, as distorções harmônicas e detecta a ocorrência de variações de tensão de curta duração. Como principais contribuições deste trabalho, pode-se citar a avaliação de métodos existentes e a proposta de um novo método para detectar a origem de distúrbios em relação à localização do medidor. Propôs-se também uma interface gráfica que permite o monitoramento dos parâmetros elétricos e de qualidade de energia, e ainda possibilita a interação do consumidor para a obtenção o de informações detalhadas sobre o estado da rede. O medidor pode ser utilizado como um registrador de dados e permite o acesso à sua interface gráfica por meio da utilização da porta de comunicação ethernet. Para a validação inicial, realizaram-se simulações computacionais, a partir de um modelo de consumidor residencial, em diferentes cenários de operação. Na etapa de validação experimental, foi utilizada uma fonte de geração de sinais e realizaram se testes com o medidor conectado à rede de distribuição de baixa tensão. A partir destas etapas foi possível verificar o funcionamento da interface gráfica e validar o funcionamento do medidor inteligente proposto. / In this study, a smart meter is presented, which considers the class S measurement methods specified at IEC 61000-4-30 standard and PRODIST. The proposed smart meter calculates RMS voltage and current values, active, reactive and apparent powers, power factor, frequency, harmonic distortions and detects short duration voltage variations. As main contributions of this study, it can be mentioned the evaluation of existing methods and the proposal of a new method to determine on which side of a recording device a disturbance originates. It’s also developed a graphical interface that allows the monitoring of electrical and power quality parameters and it enables consumer interaction to get detailed power grid information. The smart meter can also be used as a data logger and it allows access to its graphical interface through ethernet communication port. For the initial validation, computer simulations were performed through a residential consumer model in different operating scenarios. The experimental validation tests were carried out using an AC power source and the smart meter has been connected to low-voltage distribution grid. Through these steps, it was possible to verify the interface operation and to validate the proposed smart meter operation.
283

Retificador trifásico de 18 pulsos com estágio CC controlado por histerese constante

Fernandes, Rodolfo Castanho [UNESP] 03 December 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-12-03Bitstream added on 2014-06-13T20:29:04Z : No. of bitstreams: 1 fernandes_rc_me_ilha.pdf: 1607084 bytes, checksum: d60bd1d35a36564730a6c9f6b43790ab (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho propõe um novo conversor CA-CC trifásico de múltiplos pulsos com estágios CC-CC elevadores de tensão controlados pela técnica de histerese constante. Nesta proposta não são empregados indutores de interfase. A finalidade deste conversor é a de possibilitar um barramento CC regulado para aplicações embarcadas, acionamentos elétricos e afins, sempre com preocupações relacionadas aos aspectos de Qualidade de Energia Elétrica. Assim, a proposta deve apresentar elevado fator de potência, baixa distorção harmônica total de corrente drenada da rede elétrica. Ampla revisão bibliográfica, reunindo as propostas mais recentes da literatura para conversores com mesma finalidade, é feita para que sejam estudadas as estruturas de potência, técnicas de controle, versatilidade, possibilidade de isolamento galvânico e robustez. Em seguida, é detalhada a proposta principal deste trabalho por meio da apresentação do equacionamento do autotransformador, dos estágios elevadores de tensão e da técnica de controle. Esta análise permite que sejam feitas simulações com todos os elementos do conversor CA-CC e então, se desenvolva o projeto físico dos elementos magnéticos e se escolham os componentes eletrônicos do protótipo. O número reduzido de componentes de controle e a simplicidade dos circuitos de potência são grandes atrativos da proposta discutida. Todas as informações relevantes são descritas detalhadamente e, sempre que possível, meios alternativos de solucionar problemas são também apresentados, de forma que fiquem claras as possibilidades de melhoria da técnica empregada. A operação conjunta de todos os elementos mais a técnica de controle foi validada, de maneira que se comprovou, por meio de ensaios, todos os princípios de funcionamento da proposta de conversor CA-CC. Pelos resultados experimentais, obteve-se corrente drenada... / This work proposes a new AC-DC three-phase multipulse converter with DC-DC boost stages and constant hysteresis control. The objective of this converter is to provide a reliable DC bus for on-board applications, electric motor drives and similars, always considering power quality issues. Thus, the proposal presents high power factor and low harmonic distortions in the currents from the mains. A wide revision is made on other recent proposals found in the scientific literature. Different topologies are compared considering power circuits, control techniques, isolation possibility and robustness. The second chapter presents the details on the main proposal of this work and also the mathematical equations that describe the autotransformer, boost converters and control strategy. Later, simulation results are commented and discussed and the physical design is detailed. The output filter elements, power components and control elements are specified. Experimental results including main waveforms, efficiency, voltage regulation and temperature rise are presented for the autotransformer. The boost stages are also tested and its results are discussed. Finally, the proposed AC-DC converter is tested and the control technique applied to the power stage is validated
284

Filtro ativo de potência paralelo trifásico utilizando a técnica de controle por ciclo.

Lucena, Daiana Correia de 29 July 2015 (has links)
Submitted by Morgana Silva (morgana_linhares@yahoo.com.br) on 2016-07-26T17:27:31Z No. of bitstreams: 1 arquivototal.pdf: 7246392 bytes, checksum: bc6852979d737d37cb3dc2d3c4ea5da8 (MD5) / Made available in DSpace on 2016-07-26T17:27:31Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 7246392 bytes, checksum: bc6852979d737d37cb3dc2d3c4ea5da8 (MD5) Previous issue date: 2015-07-29 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The high use of reactive and non linear loads connected to the power grid have been led to a growing concern about power quality and this have been promote development of controlled rectifiers and parallel active filters using different control techniques. At this work is done a review of One Cycle Control (OCC) technique, applied to a Parallel Active Power Filter, instead other control techniques, implemented over DSP. The control strategy guarantee the unity power factor and the reduction of harmonics currents, in this system no grid voltage sensors are used. The validation of this work occurred through simulations in the software PSCAD and experimental results to settings of a parallel active power filter with a nonlinear and unbalanced load and for a a nonlinear and balanced load with a power grid which have common mode voltage. / A elevada utilização de cargas não lineares e reativas conectadas à rede elétrica têm levado a uma preocupação crescente com questões relacionadas à qualidade de energia, impulsionando a aplicação de diferentes técnicas de controle na operação de retificadores controlados e filtros ativos. Neste trabalho é feita uma avaliação da técnica de controle por ciclo (OCC – One Cycle Control) aplicada a um filtro ativo de potência paralelo, como alternativa a outras técnicas utilizadas para correção do fator de potência e distorções harmônicas, implementado através de um DSP. A estratégia de controle garante o fator de potência próximo à unidade e a redução de distorções harmônicas na corrente, não sendo utilizados sensores de tensão na rede. A validação do método utilizado ocorreu através de simulações no software PSCAD/EMTDC e resultados experimentais para cenários de um filtro ativo de potência paralelo com carga não linear e desbalanceada, e carga não linear e balanceada tendo como alimentação uma fonte de tensão que inclui uma componente de modo comum.
285

Controle repetitivo aplicado a compensadores série para correção de afundamentos e distorções harmônicas de tensão da rede elétrica.

Martins, João Raphael Souza 18 February 2016 (has links)
Submitted by Morgana Silva (morgana_linhares@yahoo.com.br) on 2016-07-27T16:18:26Z No. of bitstreams: 1 arquivototal.pdf: 1682868 bytes, checksum: e6813f2f2930d8867270563d26fb878c (MD5) / Made available in DSpace on 2016-07-27T16:18:26Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 1682868 bytes, checksum: e6813f2f2930d8867270563d26fb878c (MD5) Previous issue date: 2016-02-18 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / This work proposes a repetitive-based control for series compensator with the objective of dynamically restore the voltage applied to sensitive and critical loads of power system. The control mitigates voltage sags while also minimize harmonic distortions. Its transfer function is simple to be realized and does not require any harmonic selective filters. The control system acts on sinusoid references and it is implemented in each phase independently. Another important aspect of the proposed system are the optimization strategies to minimize either the voltage injection or the active power injection. One of these strategies is to optimize the magnitude of the compensation voltage sag with the smallest voltage magnitude injection by the series compensator. For this purpose, the compensating voltage injected must be in phase with the voltage supply. Is possible to control the injection of the voltage compensation to minimize active power injection by the series compensator to compensate a voltage sag. To perform the voltage correction with minimum active power injection were developed analytical expressions for the magnitude and angle of the injected voltage. To implement theses strategies, an recursive least-squares algorithm is used to estimate the grid voltage. A laboratory-scale series compensator was developed to validate the method. Simulations and experimental results are presented and show the efficacy of the proposed method. / Este trabalho propõe um controle repetitivo para compensadores série com o objetivo de restaurar dinamicamente a tensão aplicada a cargas sensíveis e críticas de sistemas de energia. O controle pode mitigar afundamentos de tensão ao mesmo tempo que compensa distorções harmônicas. Sua função de transferência é simples de ser implementada e não requer qualquer filtro seletivo de harmônicos. O sistema de controle atua sobre as referências senoidais e deve ser implementado em cada fase independentemente. Um outro aspecto importante do trabalho são as estratégias de otimização para minimizar a tensão de compensação ou a potência ativa fornecida pelo compensador. Um destas estratégias é a otimização pela amplitude, em que a compensação do afundamento de tensão ocorre com a menor injeção de amplitude de tensão por parte do compensador série. Para isso, a tensão injetada pelo compensador deve estar em fase com a tensão da rede afundada. Pode-se, também, controlar a injeção da tensão de compensação para minimizar a potência ativa a ser injetada pelo compensador série para compensar um afundamento de tensão. Para realizar a correção com a mínima injeção de potência ativa utilizou-se expressões analíticas para obter a magnitude e o ângulo da tensão a ser injetada. Na implementação destas estratégias foi utilizado um algoritmo recursivo de mínimos quadrados para estimar a amplitude e fase da tensão da rede. Um sistema compensador série foi montado em laboratório para validar o método. As simulações e resultados experimentais são apresentados e constatam a eficácia do método proposto.
286

Implementação de uma rede experimental de geração distribuída (GD) com energia solar: estudo de caso da Universidade de Ibagué - Colômbia / Implementation of an network experimental of distributed generation (GD) with solar energy: a case study from the University of Ibagué - Colombia

Valverde Granja, Agustín [UNESP] 23 June 2017 (has links)
Submitted by Agustin Valverde Granja (agustin.valverde@unibague.edu.co) on 2017-06-28T14:11:40Z No. of bitstreams: 1 Tesis Agustin Valverde Granja.pdf: 5383238 bytes, checksum: fc4a71b7db5d1316ec5199f86e031e0f (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-06-28T20:34:40Z (GMT) No. of bitstreams: 1 valverdegranja_a_dr_guara.pdf: 5383238 bytes, checksum: fc4a71b7db5d1316ec5199f86e031e0f (MD5) / Made available in DSpace on 2017-06-28T20:34:41Z (GMT). No. of bitstreams: 1 valverdegranja_a_dr_guara.pdf: 5383238 bytes, checksum: fc4a71b7db5d1316ec5199f86e031e0f (MD5) Previous issue date: 2017-06-23 / Esta Tese de Doutorado apresentou o estudo dos problemas de tensão originados no ponto comum de conexão de uma rede experimental para fornecer até 1.000 kWh/mês de energia solar com a rede de baixa tensão da Universidade de Ibagué, na Colômbia. Inicialmente foi feita uma introdução, onde destacou-se a importância da geração distribuída, os problemas gerados e os objetivos propostos. Em seguida, foi realizado o estudo da qualidade da energia na rede de baixa tensão, conforme as normas NTC 5001. Foi dimensionada, montada e colocada em operação uma rede experimental, utilizando a metodologia proposta nesta Tese, composta de 30 painéis solares de 260 W marca IBC solar, um inversor marca Fronius de 7,6 kW e um contador bidirecional ligados diretamente à rede através com fio de seção transversal de 6,0 mm2. A energia máxima produzida pela rede experimental foi de 850 kWh/mês, equivalente a 72,65% do total da capacidade instalada. Os painéis solares apresentaram uma eficiência média de 15,7%, a eficiência do inversor foi obtida na faixa de 75 a 94% e o desempenho global, PR, entre 0,83 e 1,30. Depois de avaliar a rede experimental seguiu-se com a análise da qualidade da energia no ponto comum de ligação registrando, em relação às perturbações de longa duração, um aumento de 2%; o desequilíbrio da tensão diminuiu 3,5%, as harmônicas de tensão aumentaram 7% na linha U1, 0,8% na linha U2 e 3% na linha U3. Em relação à corrente harmônica foi evidenciado um incremento de 22% na linha U1. Nos valores das cintilações de curto e longo prazo. Para os picos e interrupções de longa duração não foram encontrados diferenças significativas. Nas perturbações rápidas a potência ativa e reativa total no período do recesso aumentaram 58% e 42% respectivamente. A análise termográfica permitiu estabelecer um aumento da temperatura no ponto comum de ligação à rede de 7,5%. A temperatura superficial do painél foi calculada a partir do modelo matemático proposto neste trabalho para a cidade de Ibagué. O modelo foi resultado de uma análise estatística com o software Minitab e utilizou os dados da variação da radiação solar e da temperatura ambiente. Quando a temperatura do painel foi maior que a temperatura ambiente, a porcentagem de erro do modelo foi de 14,09%. O análise econômica permitiu estabelecer os custos de investimento por kWp instalado na rede experimental com ovalor de 2100 USD/kWp. O valor presente líquido (VPL) começou a apresemtar valores positivos a partir de 6,3 anos e a taxa interna de retorno (TIR) calculada para este projeto foi de 17,8%. Espera-se que as experiências no projeto possam servir de referência na aplicação da lei 1715 do governo Colombiano para o aproveitamento da energia solar. / This doctoral thesis presented the study of voltage problems originating from the common point of connection of an experimental network to provide up to 1,000 kWh / month of solar energy with the low voltage network of the University of Ibague in Colombia. Initially an introduction was made, highlighting the importance of distributed generation, the problems generated and the proposed objectives. Next, the study of the quality of the energy in the low voltage network was carried out, according to the norms NTC 5001. An experimental network was dimensioned, assembled and put into operation using the methodology proposed in this thesis, composed of 30 solar panels of 260 W brand IBC solar, a Fronius brand inverter of 7.6 kW and a bidirectional counter connected directly to the network through thread of cross-section of 6.0 mm2. The maximum energy produced by the experimental network was 850 kWh / month, equivalent to 72.65% of the total installed capacity. The solar panels had an average efficiency of 15.7%, the efficiency of the inverter was obtained in the range of 75 to 94% and the overall performance, PR, between 0.83 and 1.30. After evaluating the experimental network, it was followed by the analysis of the quality of the energy at the common point of connection, in relation to long-term disturbances, an increase of 2%; the voltage unbalance decreased by 3.5%, voltage harmonics increased by 7% in line U1, 0.8% in line U2 and 3% in line U3. In relation to the harmonic current, an increase of 22% in line U1 was evidenced. In the values of short and long term scintillations. For peaks and long-term interruptions no significant differences were found. In the fast perturbations the total active and reactive power in the period of the recess increased 58% and 42% respectively. The thermal analysis allowed to establish an increase in temperature at the common point of connection to the network of 7.5%. The surface temperature of the panel was calculated from the mathematical model proposed in this work for the city of Ibagué. The model was the result of a statistical analysis with Minitab software and used the data of solar radiation variation and ambient temperature. When the panel temperature was higher than the ambient temperature, the model error percentage was 14.09%. The economic analysis allowed us to establish the investment costs per kWp installed in the experimental network with a value of 2100 USD / kWp. The net present value (NPV) began to show positive values from 6.3 years and the internal rate of return (TIR) calculated for this project was 17.8%. It is hoped that the experiences in the project can serve as reference in the application of law 1715 of the Colombian government for the exploitation of solar energy.
287

Distorções harmônicas produzidas por inversores de geração distribuída fotovoltaica em condição de ressonância paralela /

Fortes, Rárison Roberto Acácio January 2016 (has links)
Orientador: Luís Carlos Origa de Oliveira / Resumo: Como os sistemas de energia têm sido tradicionalmente projetados para produção centralizada, a penetração de sistemas de geração distribuída na rede tem causado mudança nesse perfil, criando novos desafios operacionais que se fazem importantes para a reestruturação dos sistemas tradicionais. No entanto, este novo cenário do sistema elétrico, introduzido pela resolução 482/2012 da Agência Nacional de Energia Elétrica – ANEEL, trouxe às distribuidoras de energia um novo panorama para as atividades de operação e manutenção de suas redes e ativos, principalmente devido à bidirecionalidade do fluxo de potência na rede, originado pela conexão de sistemas de geração distribuída. Os impactos técnicos devem ser previstos e analisados, sobretudo em redes de distribuição, para garantir os padrões mínimos de qualidade da energia no ponto de consumo e evitar o comprometimento das cargas alimentadas. Dentre os impactos, destaca-se o efeito sobre os bancos de capacitores devido à injeção de distorções harmônica produzida pelos inversores de sistemas fotovoltaicos, que sob certas condições, produzem conteúdo harmônico com nível acima do limite normatizado, podendo excitar uma condição prévia de ressonância no barramento. Neste contexto, esta dissertação tem como principal objetivo analisar o comportamento do sistema elétrico em condição de ressonância paralela e avaliar o grau de comprometimento dos bancos de capacitores instalados no sistema de distribuição com presença de frequências harmô... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: As energy systems have been traditionally projected for centralized production, the penetration of distributed generation systems have caused a change in this profile, creating new operational challenges that are important for traditional systems restructuring. However, this new electrical system scenario, introduced by resolution 482/2012 of Brazilian Electricity Regulatory Agency – ANEEL, brought to energy distributors a new view to the operational and maintenance activities of their nets and actives, specially due to the net power flow bidirectionality, created by the distributed generation systems connection. Technical impacts must be estimated and analyzed, specially in distribution nets, to ensure minimum energy quality standards in the consumption point and avoid fed charges commitment. Among the impacts stands out the capacitor bench effects due to harmonic distortions injection produced by photovoltaic systems inverters, that under some conditions, produce harmonic content over the regulated limit, being able to excite a preview condition of resonance in the bus. In this context, this essay has the main objective to analyze the electrical system behavior in parallel resonance condition and evaluate the degree of commitment of the capacitor bench installed in the distribution system with harmonic frequencies and suggest technical routines to avoid the contingent operation. / Mestre
288

Desenvolvimento de sensores e instrumentação aplicados no projeto de equipamentos analisadores de qualidade de energia elétrica

Koizumi, Marcos Tsuyoshi 30 November 2012 (has links)
CAPES / Uma má qualidade de energia elétrica gera grandes prejuízos para a sociedade. Desta forma são utilizados equipamentos denominados analisadores de qualidade de energia elétrica para quantizar os valores destes distúrbios e assim determinar as causas destas anormalidades. O grande problema destes equipamentos é o custo elevado e geralmente são importados inviabilizando uma medição multiponto do sistema elétrico do cliente. Neste cenário, este trabalho objetiva fornecer subsídios e alternativas para o desenvolvimento de equipamentos analisadores de qualidade de energia, que consiste de um conjunto com sensores de corrente e tensão e um módulo central de processamento. No desenvolvimento de quaisquer sensores ou instrumentação surgem algumas dificuldades de condicionamento de sinal por causa das características elétricas do componente usado e principalmente por causa do ruído. Alguns meios de contornar estes problemas são a utilização de uma instalação adequada dos equipamentos de medição, blindagens eletromagnéticas e projeto de PCB’s. No caso de sensores magnéticos, a histerese, saturação magnética e as interferências por campos magnéticos externos introduzem erro de medida no sistema e para a resolução destes problemas foram adotadas configurações de sensores Hall em malha fechada e diferencial. Outro componente que pode ser usado é o sensor Flux-gate que possui potencialidade para medições de corrente de pequena ordem além de oferecer a vantagem de maior integrabilidade ao sistema medidor. Na sequência foi projetado e construído um registrador de tensão e corrente para análise de qualidade de energia elétrica, denominado PQ-Logger, que pode usar estes sensores mencionados anteriormente. O uso de um DSP e um chip para acessar um pendrive genérico permite o armazenamento destes dados. O PQ-Logger-Tran é outro equipamento que foi idealizado para armazenar trechos de transiente de média frequência. Os resultados indicam positivamente o uso conjunto destes sensores de corrente e o equipamento desenvolvido para o propósito de medição destes parâmetros de forma rápida e econômica na infraestrutura elétrica do cliente. / A poor quality power causes large losses to society. Thus it is used an equipment named power quality analyzers for magnitude measurement of these disturbances and determine the causes of these abnormality. The principal problem with these devices is the high cost and they usually are imported that invalidates multipoint measurement of client’s electrical system. In this scenario, this work aims to provide support and alternatives for the development of power quality analyzers, which consists of a set with voltage and current sensors and a central processing module. In the development of any sensors or instrumentation there are difficulties on signal conditioning generated from the used component’s electrical characteristics and principally noise. Some solutions for these problems is the use of proper measuring equipment installation, electromagnetic shielding and design of PCBs. For magnetic sensors, the hysteresis, magnetic saturation and interference by external magnetic fields introduce measurement error in the system and to solve these problems it was adopted Hall sensors in closed-loop and differential configurations. Another component that can be used is the Flux-gate sensor that has potential use in small range current measurements and offers the advantage of higher integrability in the meter system. Following is designed and built a voltage and current logger for Power quality analysis, called PQ-Logger that may utilize the sensors mentioned above. The use of a DSP and a chip for accessing a generic flash drive allows storage of these data. The PQ-Logger-Tran is other equipment that was designed to store snippets of mid-frequency transient. The results positively indicate the combined use of these current sensors and equipment developed for the measuring purpose of these parameters in a quickly and economically form in the customer‘s electrical infrastructure.
289

Classificação de eventos em redes de distribuição de energia elétrica utilizando modelos neurais autônomos

Lazzaretti, André Eugênio 06 July 2010 (has links)
Este trabalho apresenta uma metodologia para classificação de eventos de curto-circuito e mano-bras em redes de distribuição de energia elétrica, com base nos registros oscilográficos de tensão na barra da subestação de distribuição. São apresentados os resultados obtidos para duas formas distintas de pré-processamento dos sinais de tensão, sendo a primeira baseada em Transformada de Fourier e a segunda em Transformada Wavelet para diferentes famílias de funções wavelet. Foram comparados três modelos neurais para o processo de classificação: Multi-Layer Perceptron, Radial Basis Function e Support Vector Machine. Os modelos foram treinados levando em conta uma característica autônoma de operação das redes, ou seja, a seleção automática do modelo e o controle de complexidade. Os resultados foram validados para um conjunto de simulações realizadas no programa Alternative Transient Program, visando a aplicação prática do método proposto em um equipamento registrador de oscilografias, desenvolvido pelo Lactec em conjunto com a Copel - Curitiba, PR, denominado Power Quality Monitor. Foram obtidos resultados com desempenho na ordem de 90% de acerto médio para as diferentes formas de pré-processamento e diferente modelos neurais. / This work presents a method for automatic classification of faults and events related to quality of service in power distribution networks, based on oscillographies of the bar feeder voltages of the distribution substation. We present the results for two distinct pre-processing forms of the voltage signals. The first is based on the Fourier Transform and the second on the Wavelet Transform for different families of wavelet functions. We compared three neural models for the process of classification: Multi-Layer Perceptron, Radial Basis Function and Support Vector Machine. The models were trained taking into account the autonomous operation of networks, i.e. automatic model selection and control complexity. The results were validated for a set of simulations performed using the Alternative Transient Program, aimed at practical implementation of the proposed method in an oscillograph logger, developed by Lactec together with Copel, called the Power Quality Monitor. The results were obtained with performance on the order of 90% of average accuracy for the various pre-processing forms and neural models.
290

Investigação da estabilidade e da qualidade de energia no ponto de conexão de um inversor trifásico com filtro LCL operando de forma conectada ou ilhada sujeito a variações de carga / Investigation of the stability and power quality in the point of coupling of a grid-tied or stand-alone three-phase inverter with LCL filter under load variations

Zamodzki, Rafael 10 March 2017 (has links)
CAPES; CNPq; Fundação Araucária / A operação de unidades de geração distribuída (UGDs) é um assunto relativamente novo no cenário energético brasileiro. A conexão destas unidades à rede, bem como sua desconexão vêm sendo abordadas em pesquisas recentes em todo o mundo. É necessário que a energia elétrica entregue à rede e à carga tenha certos níveis de qualidade para que o consumidor seja devidamente atendido até mesmo em situações de contingência. Outro cuidado necessário é com relação aos sistemas de controle envolvidos, para que operem sem degradar a qualidade de energia. Neste sentido, este trabalho propõe a análise da estabilidade e da qualidade de energia no ponto de conexão de uma unidade de geração distribuída à rede e a carga ou apenas à carga, sendo ambas situações através de filtro LCL (indutivo-capacitivo-indutivo). Este tipo de filtro possui uma impedância caracterizada por um pico de ressonância próximo a sua frequência de corte. É necessário que este pico seja amortecido para que o sistema não seja levado à instabilidade. Nesta dissertação são propostos alguns casos para análise. Estes casos se diferem pela variável controlada, pela forma de operação do sistema e pela técnica não amortecimento utilizada. No caso do inversor conectado à rede e à carga, são analisados os casos em que a corrente do primeiro ou do segundo indutor de filtro é a variável controlada. Já para o caso em que o inversor está apenas alimentando a carga local, a variável controlada é a tensão no capacitor do filtro LCL. Todos estes casos são avaliados operando sem amortecimento nenhum da ressonância, com amortecimento passivo ou com amortecimento ativo. Além disso, para estes cenários há ainda a variação nos parâmetros da carga RL(resistiva-indutiva) a fim de verificar qual é a influência da variação da carga na estabilidade do sistema e na qualidade de energia no ponto de conexão. As análises de estabilidade são realizadas através de diagramas de Bode e mapas de polos e zeros do sistema. A análise da qualidade da energia realiza-se por meio de resultados experimentais obtidos em uma bancada experimental. Verifica-se através dos resultados que em termos de qualidade de energia não existem alterações significativas controlando-se diferentes variáveis no modo conectado. Além disso, constata-se também que outros fatores, além da variável controlada, do tipo de técnica utilizada para amortecimento e da frequência crítica influenciam na instabilidade ou não do sistema devido à ressonância. Através das análises, observa-se também que um controlador PI (proporcional-integral) bem ajustado pode oferecer robustez ao sistema frente às variações de parâmetros da carga e consequentes variações nas variáveis controladas. Nota-se também que para o caso ilhado, as DHTi e DHTv (Distorções Harmônicas Totais de Corrente e de Tensão) são baixas, fornecendo energia com boa qualidade para a carga local alimentada pelo sistema. / The operation of distributed generation units (DGUs) is a relatively recent issue in the Brazilian energetic scenario. The connection of these units to the grid, as their disconnection are being approached in recent researches worldwide. It is necessary that the electrial power delivered to the grid and to the power has some levels of quality so the consumer may be well attended even in contingence situations. Another necessary caution is related to the control systems involved, so they operate without degrade the power quality. At this point, this work proposes the stability and power quality analysis in the point connection of a distributed generation unit to the grid and to the load or just to the load, both situations through LCL (inductive-capacitive-inductive) filter. This kind of filter has an impedance that is characterized by resonance peak near to its cut-off frequency. It is necessary to damp this peak in order that the sytem is not lead to instability. In this Master Thesis, some cases are proposed to be analyzed. These cases differ one from another because of the controlled variable, by the kind of operation of the system and by the damping technique that is used. In the case of the grid and load-tied inverter, the analyzed cases are those in which the first or second filter inductor current is the controlled variable. For the case in which the inverter is just feeding the local load, the controlled variable is the LCL filter capacitor voltage. All of these cases are evaluated by operating with none resonace damping, passive damping or active damping. Beyond this, for these scenarios, there is the parameters variation of the RL (resistive-inductive) load in order to check which is the influence of the load variations in the system stability and in the power quality at the connection point. The stability analysis are performed through Bode diagrams and pole-zero maps of the system. The power quality analysis is carried out by means of experimental results obtained in an experimental bench. It is verified through the results that in terms of power quality, there is not significantly changes by controlling different variables in the grid-tied mode. Furthermore, other factors, beyond the controlled variable, the kind of damping technique and the criticak frequency influence in the instability of the system due to the resonance. Through the analysis, it is oberserved that a well-adjusted PI (proporcional-integral) controller may offer robustness to the system under load parameter variations and consquent controlled variable variations. It is also noted that for the stand-alone case, the THDi and the THDv (Total Harmonic Distortions of Current and Voltage) are low, providing good power to the local load fed by the system.

Page generated in 0.0348 seconds