• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 267
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 269
  • 108
  • 92
  • 71
  • 70
  • 66
  • 55
  • 48
  • 47
  • 46
  • 41
  • 41
  • 37
  • 32
  • 31
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Tecnologia de aplicação de produtos fitossanitários na cultura da uva na região do Vale do São Francisco

Lemos, Raphael Emilio [UNESP] 28 August 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:29Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-08-28Bitstream added on 2014-06-13T19:16:28Z : No. of bitstreams: 1 000739204.pdf: 41645242 bytes, checksum: 0d265664adf1acf331ffe31de6bcae7f (MD5) / A produção de uva no Vale do São Francisco é uma atividade promissora devido às suas características climáticas e o empenho geral em desenvolver a agricultura da região, visando alcançar mercados internacionais. Com isto, a ocupação agrária local sofreu um crescimento abrupto, que requer o desenvolvimento de tecnologias locais para a manutenção da sustentabilidade da produção. Devido à exigências de programas que têm se preocupado com a qualidade do produto colhido, envolvendo à proteção ao ambiente, a segurança alimentar, às condições de trabalho, a saúde humana e a viabilidade econômica, a vitivinicultura necessita de amparo para atualizar conceitos técnicos de produção. A presente proposta se baseou nesta necessidade e visa avaliar a situação atual de utilização e propor possíveis aprimoramentos sobre a tecnologia de aplicação de produtos fitossanitários, visando um controle eficaz de pragas e doenças, para manter a qualidade à fruta colhida, minimizar contaminações ambientais e proteger usuários e operadores envolvidos com o tratamento fitossanitário / Grape production in San Francisco Valley, north of Brazil, is a interesting culture for the development of this region that has got many good features to this agrarian culture, aimed an international markets. Therefore, the agricultural occupation have been growing what requires a necessary development of local technologies to maintain a sustainable production..According of that, this paper addressed the effects of the current situation of production and suggested possible improvements in the technology of applying pesticides for effective control of pests and diseases and improve the quality of fruit harvested in order to minimize environmental contamination and protect users and operators involved in the plant treatment
162

AVALIAÇÃO DE TRÊS SISTEMAS DE APLICAÇÃO DE PRODUTOS FITOSSANITÁRIOS LÍQUIDOS / EVALUATION OF THREE LIQUID FITOSSANITARY PRODUCTOS APPLICATION SYSTEMS

Silva, Marcelo Prado Lima da 06 May 2004 (has links)
At present days agriculture has been looking for new technologies for quickly supplying the human needs in foods. It is undeniable that the use of machines in the agriculture as well as the discovery and application of new agricultural techniques or modern and efficient cultural methods allowed the increase of the production and agricultural productivity in the world, enlarging in a significant way, the income of the work, the areas of the cultures and the respective productions, reducing the hand of manual work in the accomplishment of the agricultural works, mainly the dangers to the human health. Due to those technological progresses there is a series of alternatives at the farmer's reach, but that, due to great speed in the innovations, he doesn't have enough information to choose for one or other more appropriate technique. That work had as subject to evaluate a new drag pulverization system (SPAR) as well as to compare it with the two more used systems which are: bars pulverizer and agricultural aviation. Three parameters were used to compare the systems and evaluate, operational capacity, mechanical damages and drops deposition. Regarding to the operational capacity the SPAR system was 100% superior on average to the pulverizer equipped with normal bars under tests conditions. Aerial application under tests conditions presents a superior operational capacity in relation to the two terrestrial systems. For mechanical damages doesn t exist any medium productivity difference among the systems, however, in grassy having between nodes as corn and sorghum should only be used the SPAR system in the initial phase of the culture before the between nodes appearance. The SPAR system has the larger penetration of the product in the inferior layer of the dossal. Within statistical terms didn't exist significant differences among the systems with fungicides application in soybean productivity / É inegável que o uso de máquinas na agricultura, bem como, a aplicação de novas técnicas agrícola, permitiu o aumento da produção e produtividade agrícola no mundo. Há uma série de alternativas a disposição do agricultor. Este trabalho serviu para avaliar um novo sistema de pulverização de arrasto (SPAR) e comparar com os dois sistemas mais utilizados que são: pulverizador de barras e aviação agrícola. Para avaliar e comparar os sistemas foram utilizadas três variáveis que foram: Desempenho operacional, danos mecânicos e deposição de gotas. Para a realização da análise de deposição de gotas foram utilizados papéis hidro-sensíveis, fixados nas entrelinhas e junto às linhas do dossel vegetativo a 30 e 60 cm de altura. Desta forma determinou-se à densidade de gotas e o DMV (Diâmetro médio volumétrico). Os danos mecânicos foram estimados com a determinação da produção em áreas com e sem amassamento pelo rodado do trator. Por diferença se obteve as perdas por danos mecânicos pelos sistemas terrestres. O sistema aéreo foi considerado como dano zero. Foi mensurado também o dano causado pelo arraste da mangueira de pulverização sobre as culturas pelo sistema SPAR. O desempenho operacional foi baseado nos tempos operativos, determinando capacidade de campo operacional e rendimento de campo. Para a avaliação do sistema SPAR foi realizada uma série de medições de desempenho operacional variando condições e tamanhos das áreas e sistemas de abastecimento. Quanto à capacidade operacional o sistema SPAR foi em média 100% superior ao pulverizador equipado com barras normais, nas condições dos testes. A aplicação aérea possui uma capacidade operacional superior aos dois sistemas terrestres. A redução da produtividade, por amassamento, é mais significativa pelo sistema de barras. Em gramíneas com entrenós, como milho e sorgo, deve-se utilizar o sistema SPAR somente na fase inicial da cultura antes do surgimento dos entrenós. O sistema SPAR possui maior penetração do produto na camada inferior do dossel. Estatisticamente não existiram diferenças significativas entre as variáveis utilizadas para diferenciar os sistemas avaliados, na aplicação de fungicidas em produtividade de soja
163

Quantificação do ar incluído e espectro de gotas de pontas de pulverização em aplicações com adjuvantes

Mota, Alisson Augusto Barbieri [UNESP] 08 February 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:39Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-02-08Bitstream added on 2014-06-13T20:31:53Z : No. of bitstreams: 1 mota_aab_me_botfca.pdf: 2185132 bytes, checksum: bc81471882e24fbbd82fb00386fab303 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O presente trabalho teve por objetivo verificar a interferência de adjuvantes na quantidade de ar incluído em gotas geradas por pontas com indução de ar, bem como avaliar o espectro resultante destas condições de pulverização. Para o estudo foram utilizadas nove caldas, sendo uma composta apenas por água e oito soluções contendo adjuvantes (óleo mineral, óleo vegetal, mistura de lecitina e ácido propiônico, nonil fenoxi poli etanol, dois adjuvantes a base de nonil fenol etoxilado, copolímero de poliéster e silicone, e lauril éter sulfato de sódio) e três pontas de pulverização jato plano, sendo duas com indução de ar (Air Guardian e Ultra Lo-Drift – Hypro) e uma com pré-orifício (Drift Guard – Spray Systems). O estudo foi realizado em duas etapas, sendo elas a quantificação do ar incluído nas gotas de pulverização e a análise do espectro produzido. O ar incluído foi calculado através da diferença de volume da mistura pulverizada (ar mais líquido) e apenas do líquido, que foi feito por meio de coletas de amostras de pulverização em uma proveta graduada. A determinação do espectro de gotas foi realizada por um analisador de tamanho de partículas por difração de raios laser Mastersizer S (Malvern Instruments). Para análise estatística os valores das variáveis do espectro de gotas e % ar incluído para os diferentes adjuvantes e pontas foram comparados pelo Intervalo de Confiança para Diferenças entre as Médias a 5 % de probabilidade (IC95%). Também foram feitas as correlações entre as diferentes variáveis através do coeficiente de Pearson a 5% de probabilidade. As análises do espectro de gotas demonstraram diferenças entre os adjuvantes, assim como diferenças de comportamento dos adjuvantes de acordo com o tipo de ponta. Todos os adjuvantes ocasionaram o aumento do percentual de ar incluído nas gotas em relação à água, observando... / This study aimed to verify the influence of adjuvants on the amount of air included in droplets generated by spray nozzles with air induction, as well as to evaluate the droplet spectrum generated in these conditions. For the study, it were used nine spray solutions, one including only water and eight containing adjuvants (mineral oil, vegetable oil, a mixture of lecithin and propionic acid, nonyl phenoxy poly ethanol, the two adjuvants based on nonyl phenol ethoxylate based, copolymer polyester and silicon, and sodium lauryl ether sulfate) and three flat fan spray nozzles, including two air induction (Air Guardian and Ultra Lo-Drift - Hypro) and a pre orifice (Drift Guardian - Spray Systems). The study was conducted in two steps: the quantification of air included in the spray droplets and the droplet spectrum produced. The amount of air included was calculated by the difference in volume of the solution after praying (liquid plus air) and only the solution (before spraying), which was done by collecting samples of the solutions in a graduated cylinder. The determination of the droplet spectrum was carried out by a particle size analyzer by laser device Mastersizer S (Malvern Instruments). Data collected for the variables of droplet spectrum and air included with different adjuvants and nozzles were subjected to statistical analysis by the calculation of the Confidence Interval at 95% (CI95%). Correlations between different variables were calculated by Pearson's correlation at 5% probability. The analysis of the droplet spectrum showed differences between the different adjuvants, as well as differences in the behavior of adjuvants according to the type of nozzle. All adjuvant caused an increase in the percentage of air included compared to the water, in which some different behaviors were observed for each nozzle. Looking at the relations between the variables... (Complete abstract click electronic access below)
164

Potencial de redução da deriva em função de adjuvantes e pontas de pulverização

Chechetto, Rodolfo Glauber [UNESP] 18 July 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:39Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-07-18Bitstream added on 2014-06-13T18:20:53Z : No. of bitstreams: 1 chechetto_rg_me_botfca.pdf: 469390 bytes, checksum: 8e9fa1d749c62128208266d3bf55add5 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A importância da aplicação de agrotóxicos em cultivos agrícolas e a preocupação crescente com a segurança e a responsabilidade ambiental têm incentivado o desenvolvimento de novas tecnologias visando a redução do risco de deriva. Neste contexto, o objetivo deste trabalho foi estimar o potencial de deriva com diferentes pontas de pulverização e diferentes concentrações de adjuvantes. O ensaio foi instalado com seis caldas provenientes da diluição de diferentes tipos de adjuvantes a base de óleo vegetal, óleo mineral, surfactante e redutor de deriva, as quais foram aplicadas com duas pontas de pulverização, sendo uma de jato plano com pré-orifício (DG 8003 VS) e outra de jato plano com indução de ar (AI 8003 VS), totalizando 12 tratamentos com 3 repetições. O trabalho foi realizado em duas fases, sendo que na primeira o percentual de deriva foi analisado em condições controladas em túnel de vento e na segunda determinaram-se as características do espectro de gotas das pontas, utilizando-se um equipamento analisador de partículas em tempo real Mastersizer S (Malvern Instruments). As médias dos tratamentos foram comparadas pelo Intervalo de Confiança, ao nível de 95% de probabilidade e as correlações entre as variáveis foram analisadas utilizando o coeficiente de Pearson a 5% de probabilidade. A análise do espectro de gotas demonstrou diferentes comportamentos para cada tipo de adjuvante e ponta de pulverização. Para a porcentagem de deriva os tratamentos tiveram comportamento distinto, sendo o adjuvante a base de nonil fenol etoxilado o que apresentou maior interação, sendo a maior deriva com a ponta de pré-orifício e a menor deriva com a ponta com indução de ar. O comportamento dessas pontas foi inverso, para o potencial de deriva, quando o adjuvante a base de óleo foi utilizado / The importance of pesticide applications in crops and security and ambient responsibility concern has encouraged new techniques development aiming drift reduction. In this context, the objective of this work was estimate drift potential using different spray nozzles and adjuvants concentrations. The experiment was installed containing six solutions from different type adjuvant dilution, as vegetal oil, mineral oil, surfactant and drift reduction, which were applied with two nozzle, one pre-orifice flat fan (DG 8003 VS) and other of air induction flat fan (AI 8003 VS), resulting in 12 treatments with 3 replications each. The experiment was realized in two steps. In the first step, the drift percentage was analyzed in controlled conditions in wind tunnel and the second one determined droplet spectra characteristics, using a real time particle analyzer Mastersizer S (Malvern Instruments). The treatments averages were compared using Confidence Interval at 5% probability and the correlations between variables were analyzed using Pearson at 5% of probability. The analysis of droplet spectrum showed different behavior for each adjuvant and nozzle. Looking at drift percentage the treatments had different behavior and the nonil phenol ethoxylate adjuvant showed greatest influence with the highest drift for pre-orifice nozzle and the lowest for air induction nozzle. The nozzles behaviors were opposite for drift percentage when an oil-base adjuvant was used
165

Otimização da tecnologia de assistência de ar em pulverizador de barras através da umidificação do fluxo de ar

Stanislavski, Wilson Marcos [UNESP] 29 August 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:41Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-08-29Bitstream added on 2014-06-13T20:12:49Z : No. of bitstreams: 1 stanislavski_wm_me_botfca.pdf: 539468 bytes, checksum: 9eeb49e3eba11e828c08973394be034e (MD5) / Universidade Estadual Paulista (UNESP) / A aplicação terrestre com assistência de ar é bastante difundida e tem sido incentivada devido ao potencial de maior eficiência quando comparada a aplicação terrestre convencional. Pulverizador com barra assistida a ar são amplamente utilizados em culturas de grandes extensões e em algumas situações de difícil penetração das gotas no dossel de culturas como soja e algodão. Entretanto, devido às grandes variações climáticas que ocorrem durante o período de aplicação, o rendimento operacional é prejudicado pelas paradas devido à baixa umidade relativa do ar e altas temperaturas. O objetivo deste trabalho foi pesquisar uma forma de umidificar o ar e avaliar a interferência desta umidificação na temperatura e umidade relativa na cortina de vento em pulverizador com tecnologia de assistência de ar. Os tratamentos corresponderam a diferentes ajustes e vazões de água de um dispositivo de umidificação, os quais foram relacionados às condições climáticas no momento da pesquisa. A pesquisa foi dividida em duas fases. Numa fase inicial exploratória o sistema de umidificação foi montado próximo a parede interna do duto de ar, pulverizando água com os bicos fixados a 45° em relação à direção do fluxo de ar. Nesta fase verificou-se que as gostas não seguiam o fluxo de ar, sendo direcionadas para a parede do duto, causando escorrimento e não obtendo alteração na temperatura e umidade na cortina de ar. Na segunda fase montou-se um ramal umidificador no centro do duto de ar, com os bicos pulverizando no sentido do fluxo. Os resultados mostraram que houve redução significativa da temperatura e aumento significativo da umidade relativa do ar na cortina de ar. A vazão de 0,48 L.min.-1 no sistema de umidificação proporcionou a melhor eficiência em relação à redução da temperatura na cortina de ar... / Air assisted ground applications are widespread and have been encouraged due to the potential for greater efficiency when compared to conventional ground application. Sprayers with airassisted boom are widely used in large-area cultures and in some situations of difficult penetration of droplets in the canopy of cultures, such as soybean and cotton. However, due to large climatic variations that occur during the application period, the operational return is affected by interruptions caused by low relative air humidity and high temperatures. This study aimed to investigate a way to humidify the air and to assess the interference of this humidification in the temperature and relative humidity in the air flow of air-assisted sprayers. The treatments corresponded to different water adjustments and flow rates of a humidification device, which were related to climatic conditions at the time of the survey. The study was divided into two phases. In an initial exploratory phase, the humidification system was mounted near the intern wall of the air duct, spraying water with nozzles set at 45° in relation to the direction of the air flow. At this stage, it was verified that the droplets did not follow the air flow, being directed towards the duct wall causing dripping and getting no alteration in temperature and in humidity of the air flow. In the second stage, a humidifier extension was mounted in the center of the air duct, with nozzles spraying in the flow direction. Results showed a significant reduction in temperature and a significant increase in the relative humidity of the air flow. A flow rate of 0.48 L.min.-1 in the humidification system provided the best efficiency regarding temperature reduction in the air flow, resulting in... (Complete abstract click electronic access below)
166

Uso de videografia digital para avaliação da estabilidade da barra de pulverização em área de florestamento

Queiroz, Carolina Aparecida de Souza [UNESP] 28 June 2001 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:44Z (GMT). No. of bitstreams: 0 Previous issue date: 2001-06-28Bitstream added on 2014-06-13T19:06:22Z : No. of bitstreams: 1 queiroz_cas_me_botfca.pdf: 654928 bytes, checksum: e1d54b95eb20a4fb3aa845551c151b66 (MD5) / O presente trabalho teve como objetivo avaliar a estabilidade barras pulverizadoras, com e sem sistema estabilizador, operando em condições de cultivo mínimo florestal. Os tratamentos foram organizados de maneira fatorial e delineados em esquema de parcelas subdivididas com quatro repetições, sendo duas parcelas: pulverizadores com e sem sistema estabilizador de barras - CE e SE, respectivamente; e três subparcelas: velocidades de deslocamento de 1,25 m/s (terceira marcha reduzida), 1,50 m/s (quarta marcha reduzida) e 2,00 m/s (primeira marcha simples). A movimentação das barras foi avaliada através de videografia digital, sendo as imagens analisadas em softwares específicos para o cálculo dos valores dos movimentos horizontais e verticais das barras. Os resultados mostraram que, nas condições de realização deste trabalho, a utilização de barra com estabilizador proporcionou melhor resultado com relação a amplitude do movimento vertical, diminuindo a oscilação da mesma. Houve interação entre o tipo de barra (com e sem estabilizador) e a velocidade de deslocamento do trator para a análise dos movimentos horizontais da barra, observando-se diferenças entre as velocidades apenas na barra sem estabilizador. Na comparação entre os tipos de barras houve diferença estatisticamente significativa para movimentos horizontais apenas na menor velocidade de deslocamento, sendo maior a amplitude obtida com a barra sem estabilizador. No caso dos movimentos verticais esta diferença não foi observada. Com relação a metodologia desenvolvida, considera-se que a mesma se mostrou adequada aos objetivos do trabalho. / This study has as aim to value two kinds of boom sprayer operating at forestry minimum tillage conditions. It was used spray booms with and without stabiliser system evaluated in three forward speeds. The vertical and horizontal movements were analysed by digital video recording. The treatments were outlined at subdivided parcels with four repetitions, two parcels: sprayer boom with and without stabiliser system, and three subparcels: three forward speeds 1.25, 1.50 and 2.00 m/s, resulting in 24 parcels. The results showed that the boom with stabiliser system gave better performance related to vertical movements. There was interaction between the use of the stabiliser system and forward speed on the horizontal movements showing differences among the speeds only on the boom without stabiliser. The methodology can be considered adequate to the aim of this work.
167

Desenvolvimento de sistema auxiliar de resfriamento evaporativo, para arrefecimento de transformadores de força

Araújo, Ismael Nickson Pinto de 26 February 2016 (has links)
Submitted by Maike Costa (maiksebas@gmail.com) on 2017-05-30T13:23:04Z No. of bitstreams: 1 arquivototal.pdf: 4122631 bytes, checksum: 3dbd65166aa3a3cad90e903290833e6a (MD5) / Made available in DSpace on 2017-05-30T13:23:04Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 4122631 bytes, checksum: 3dbd65166aa3a3cad90e903290833e6a (MD5) Previous issue date: 2016-02-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The consumption of electricity in our social environment such as in houses, apartments, business, industries, hospitals, it’s achieved thanks to an equipment that makes the levels of tension and electric current acceptable as demanded by the standards, so we can benefit from electricity in a safe and efficient way, these equipment are the power transformers. Due your relevance, techniques that retard or avoid the failures in these equipment, aiming a better availability and a smaller number of maintenance stops, are the theme of several researchers and studies centers. A very common failure in medium and large transformers that are used in transmission and distribution of power, is the degradation of the insulating function of transformer's core that it is caused mainly by the adverse gradient of temperature that circulates in the core through the insulating oil. The present work analyzes the efficiency of a transformer's cooling auxiliary system, that aims dissipate the heat absorbed by the oil in a quick and efficient way, decreasing the degradation of the insulating function and increasing its lifespan. The system consist of water spray nozzles, that it will be installed in the transformer’s radiator, in front of the fans, in the same direction of the air flow. The water spraying in the air flow, will cause a temperature decrease and a humidity increase, due to a phenomenon known as evaporative cooling, where heat from the air makes the small drops of water evaporate quickly. It will be analyzed the water flow rate in the spraying, the amount and placement of the water spray nozzles through the radiator and the air flow of the fans. So the system has thermal and energetic efficiency. Will be used a control system that includes a variable-frequency drive (VFD), temperature sensors and a data acquisition board (DAQ), all monitored through LabVIEW. / O consumo de energia elétrica no nosso convívio social como, casas, apartamentos, comércio, indústria, hospitais, é conseguido graças a um equipamento que torna os níveis de tensão e corrente elétrica em valores aceitáveis exigidos por norma, para que possamos usufruir da energia elétrica de maneira segura e eficiente, esses equipamentos são os transformadores de força ou de potência. Visto sua importância, técnicas que retardam ou evitem falhas nesse equipamento, visando a maior disponibilidade e com isso menos paradas para manutenção, são tema de estudo de diversos pesquisadores e centros de ensino. Uma falha bastante comum em transformadores de médio a grande porte que são utilizados na transmissão e distribuição de energia, é a degradação do papel isolante do núcleo do transformador, que é causada principalmente pelo gradiente adverso de temperatura que circula no núcleo através do óleo isolante. Logo o presente trabalho analisa a eficiência de um sistema auxiliar de arrefecimento do transformador, que visa dissipar o calor absorvido pelo óleo de maneira rápida e eficiente, diminuindo a degradação do papel isolante e aumentando sua vida útil. O sistema será composto por bicos pulverizadores de água, que serão instalados nos radiadores do transformador, em frente aos ventiladores, no mesmo sentido do fluxo de ar. A pulverização de água nesse fluxo de ar, irá causar uma diminuição da temperatura e um aumento de umidade, isso devido a um fenômeno conhecido como resfriamento evaporativo, onde as pequenas gotas de água recebem o calor do ar e se evaporam rapidamente. Será analisado a vazão de água na pulverização, a quantidade e o posicionamento dos bicos ao longo do radiador e o fluxo de ar dos ventiladores, para que o sistema tenha eficiência térmica e energética. Será utilizado um sistema de controle composto por inversores de frequência, sensores de temperatura e placa de aquisição de dados, que serão monitorados pelo LabView.
168

Automatização de pulverizador pneumático visando à eficiência da aplicação e redução de impactos ambientais / Automation of pneumatic sprayer aiming the application efficiency and reduction of environmental impacts

Manhani, Gustavo Guethi 11 July 2011 (has links)
Made available in DSpace on 2015-03-26T13:23:47Z (GMT). No. of bitstreams: 1 texto completo.pdf: 6311781 bytes, checksum: c20eb3012fd8469ba4d004e8fe229f80 (MD5) Previous issue date: 2011-07-11 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The lack of knowledge of pesticide application technology by growers aggravates the problems associated to the application of poor quality, increasing product losses and environmental contamination. In the field, it is difficult to control all factors that affect the application, for example, weather conditions. Physically, the water vapor pressure deficit in the air (VPDair) determines the evaporative capacity of the environment, being an important meteorological variable to be considered during the applications. To avoid the adverse weather conditions, there is a need for adjustment of parameters during the application in the field. An alternative is the use of embedded technology provided with sensors and microcontrollers for automation equipment. In the pneumatic spraying, it is possible a variation of the application parameters by controlling the air volume responsible for the droplets fractionation. Therefore, this study aimed to automate a pneumatic sprayer for setting the application technical parameters against the diversity of weather conditions. To control the air flow a diaphragm was built from a galvanized steel sheet and placed onto the fan inlet. Eight diaphragm openings were studied between 30 and 100 % of initial diameter. The fan characteristic curve for each opening was obtained with the aid of a Pitot tube for the measurement of air velocities. It was used a thermocouple at the cannon outlet to measure the temperature of the air stream produced by the fan. For application in the field, it were established three classes for evaporative capacity of air, specified as low (VPDair &#8804; 7,01 hPa), medium (7,01 &#8804; VPDair &#8804; 12,67) and high (12,67 &#8804; VPDair &#8804; 30,00 hPa). Thus, the application did not occur when the VPDair was higher than 30,00 hPa. The 30 and 40 % of diaphragm openings were excluded for not producing enough atomization. It were evaluated the volumetric median diameter, the droplets density, the coverage percentage, the homogeneity coefficient and the relative amplitude, for each interval of VPDair. For automation, it was built an electromechanical system associated to an electronic system comprised of microcontroller, temperature and relative humidity sensor and position sensors that were placed into the mechanical structure. It was developed a system control algorithm for adjustment of the diaphragm opening to the interval of VPDair. It was evaluated the response time and the accuracy of diaphragm positioning for a weather condition. The highest and lowest air flow was obtained with the diaphragm openings of 100 and 50 %, corresponding to the air flows of 51,28 m3 min-1 e 38,97 m3 min-1, respectively. Between the diaphragm openings of 100 and 70 % the air flow decreased 4,56 %. For the other diaphragm openings 60, 50, 40 e 30 %, there was air flow reduction of 14,08; 24,00; 35,37 and 47,09 %, respectively. With the closing of the diaphragm, it occurred an increasing on the air temperature at the fan outlet, reaching 36 °C when the environment temperature was 27 °C. The highest droplets size were obtained at the lowest air flow, and that, with the elevated heating at the fan outlet, associated to the low application rate, did not allowed the formation of higher droplets size. The application useful range was reduced as the air flow reduced and there was a increasing on the VPDair, by the increasing of the evaporation process. It was noticed similar application behavior in the low and medium evaporative capacity of the air, due to the narrow range between them. Every application parameters analyzed had its values reduced in the highest interval of VPDair, by the higher evaporative power of the environment. It was found for the automated sprayer air flows statistically different to 5 % probability, with good accuracy, based on the values of the coefficient of variation, which was below 3,5 %. The longest positioning response time of the diaphragm was 66,3 seconds, which, for a travel speed of 2,6 km h-1, represents a distance traveled of 47,88 meters. The system showed good accuracy of response time, with every components analyzed having a coefficient of variation below 5,0 %. / O pouco conhecimento da tecnologia de aplicação de agrotóxicos pelos produtores agrava os problemas associados à aplicação de má qualidade, aumentando as perdas de produto e a contaminação do ambiente. Em campo, é difícil obter o controle de todos os fatores que interferem na aplicação, como, por exemplo, as condições meteorológicas. Fisicamente, o déficit de pressão de saturação do vapor de água no ar (DPVar) determina a capacidade evaporativa do ambiente, sendo uma variável meteorológica importante a ser considerada durante as aplicações. Para contornar as condições meteorológicas adversas, há a necessidade da adequação dos parâmetros durante a aplicação em campo. Uma alternativa é o uso da tecnologia embarcada provida de sensores e microcontroladores para automatização dos equipamentos. Na pulverização pneumática, é possível uma variação dos parâmetros da aplicação a partir do controle do volume de ar responsável pelo fracionamento das gotas. Portanto, objetivou-se com este trabalho automatizar um pulverizador pneumático para o ajuste dos parâmetros técnicos da aplicação frente à diversidade das condições meteorológicas. Para o controle da vazão de ar foi construído um diafragma de chapa de aço galvanizada e posicionado na entrada do ventilador. Foram previamente estudadas oito aberturas do diafragma, entre 30 e 100 % do diâmetro inicial. A curva característica do ventilador, para cada abertura do diafragma, foi obtida com auxílio de um tubo de Pitot para a medida das velocidades do ar. Utilizou-se um termopar na saída do bocal do canhão para a medição da temperatura da corrente de ar produzida pelo ventilador. Para aplicação em campo, foram estabelecidas três classes de capacidade evaporativa do ar, especificadas como baixa (DPVar &#8804; 7,01 hPa), média (7,01 < DPVar &#8804; 12,67 hPa) e alta (12,67 < DPVar &#8804; 30,00 hPa). Assim, não ocorreu a aplicação quando o DPVar estava acima de 30,00 hPa. As aberturas de 30 e 40 % foram descartadas por não produzirem suficiente atomização. Avaliaram-se o diâmetro da mediana volumétrica, densidade de gotas, percentagem de cobertura, coeficiente de homogeneidade e amplitude relativa para as aberturas do diafragma, em cada intervalo de DPVar. Para a automatização, foi construído um sistema eletromecânico associado a um sistema eletrônico formado por microcontrolador, sensor de temperatura e umidade relativa do ar e sensores de posição que foram colocados na estrutura mecânica. Foi desenvolvido um algoritmo de controle do sistema para a adequação da abertura do diafragma à faixa de DPVar. Avaliou-se o tempo de resposta e a precisão de posicionamento do diafragma para uma determinada condição meteorológica. A maior e menor vazão de ar foi obtida nas aberturas de 100 e 50 % do diafragma, correspondendo às vazões de 51,28 m3 min-1 e 38,97 m3 min-1, respectivamente. Entre as aberturas de 100 e 70 % a vazão de ar reduziu 4,56 %. Para as demais aberturas 60, 50, 40 e 30 %, houve redução na vazão de ar de 14,08; 24,00; 35,37 e 47,09 %, respectivamente. Com o fechamento do diafragma, ocorreu aumento da temperatura do ar na saída do ventilador, chegando a 36 °C quando a temperatura ambiente era de 27 °C. Os maiores tamanhos de gotas foram obtidos nas menores vazões de ar, sendo que, o aquecimento elevado na saída do ventilador, associado ao baixo volume de aplicação, não permitiu a formação de gotas de maior diâmetro. As faixas úteis de aplicação foram reduzidas conforme o decréscimo da vazão de ar e houve o aumento do DPVar, pelo aumento no processo de evaporação. Observou-se comportamento semelhante de aplicação nas maiores vazões de ar para as condições de baixa e média capacidade evaporativa do ar, devido à estreita faixa entre eles. Todos os parâmetros da aplicação analisados tiveram valores reduzidos no maior intervalo de DPVar, pelo maior poder evaporativo do ambiente. Encontrou-se para o pulverizador automatizado vazões de ar estatisticamente diferentes à 5 % de probabilidade, com boa precisão, baseado nos valores do coeficiente de variação, que esteve abaixo de 3,5 %. As vazões de ar obtidas tiveram valores bem próximos daquelas tomadas manualmente. O maior tempo de resposta de posicionamento do diafragma foi de 66,3 segundos, o que, para uma velocidade de 2,6 km h-1, representa uma distância percorrida de 47,88 metros. O sistema apresentou uma boa precisão de tempo de resposta, com todos os componentes analisados possuindo coeficiente de variação abaixo de 5,0 %.
169

Perda por evaporação na pulverização em função das condições psicrométricas do ar / Pesticides evaporation depending on air psychrometric conditions

Maciel, Christiam Felipe Silva 19 July 2013 (has links)
Made available in DSpace on 2015-03-26T13:23:50Z (GMT). No. of bitstreams: 1 texto completo.pdf: 4717904 bytes, checksum: 1be9eb66894386807a86c6440b62080b (MD5) Previous issue date: 2013-07-19 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Pesticides loss by evaporation causes inefficiency of spraying, besides causing environmental impacts and intoxications. Thus, to ensure a safe pesticides application, with maximum efficiency and minimum environmental impact, the aim of this work was to characterize the hydraulic spray nozzles, determine the droplet spectrum depending on air psychrometric conditions, and to estimate and to model pesticides evaporation depending on air psychrometric conditions. During the nozzle characterization two models of nozzle were used to obtain the pattern and uniformity of distribution, as well as the droplet spectrum. The symmetry of distribution was also obtained from the data of pattern of distribution. The determination of droplet spectrum, and the estimation and modeling of pesticides evaporation depending on air psychrometric conditions were carried out inside of a climatic chamber to obtain twenty air vapor pressure deficit (VPDair) levels. The determination of droplet spectrum was performed by the laser particle analyzer model Spraytech. The nozzles LD 11002 and MAG-2 did not have good uniformity of distribution for the boom height specified by the manufacturer. The nozzle LD 11002 showed asymmetry and this was influenced by working pressure. The droplets diameter produced by the nozzles LD 11002 and MAG-2 reduced with increasing the working pressure. Increasing VPDair, increased the VMD, the Dv90, the SPAN and the percentage of sprayed volume comprised by droplets larger than 600 &#956;m, on the other hand reduced the percentage of sprayed volume comprised by droplets with diameter between 100 and 200 &#956;m, between 200 and 300 &#956;m, between 300 and 400 &#956;m, between 400 and 500 &#956;m and between 500 and 600 &#956;m. Even obeying the recommended climatic conditions for pesticides application, there is loss of sprayed volume by evaporation. For the spray nozzle LD 11002 and working pressure of 300 kPa, the pesticides loss by evaporation can reach approximately 27 % under weather conditions characterized by low wind velocity, high air temperature and low relative humidity. / A perda por evaporação de líquido pulverizado causa ineficiência da aplicação de agrotóxicos, além de causar impacto ambiental e intoxicação de pessoas. Portanto, para garantir uma aplicação de agrotóxicos segura, com máxima eficiência e mínimo impacto ambiental, objetivou-se com este trabalho realizar a caracterização de pontas hidráulicas de pulverização, determinar o espectro de gotas em função das condições psicrométricas do ar, e estimar e modelar a perda de agrotóxicos por evaporação em função das condições psicrométricas do ar. Durante a caracterização da ponta hidráulica foram utilizados dois modelos de pontas para obtenção do perfil e da uniformidade de distribuição, além do espectro de gotas produzido por estas pontas. A simetria de distribuição também foi verificada a partir dos valores do perfil de distribuição. A determinação do espectro de gotas, e a estimativa e modelagem da perda de agrotóxicos por evaporação em função das condições psicrométricas do ar foram realizadas dentro de uma câmara climática para permitir a obtenção de vinte déficits de pressão de saturação de vapor d água no ar (DPVar). A determinação do espectro de gotas foi feita empregando-se o analisador de partículas a laser modelo Spraytech. As pontas hidráulicas LD 11002 e MAG-2 não apresentaram uniformidade de distribuição satisfatória à altura de trabalho recomendada. A ponta LD 11002 apresentou assimetria e esta foi influenciada pela pressão de trabalho. O diâmetro de gotas produzido pelas pontas LD 11002 e MAG-2 reduziu com o aumento da pressão de trabalho. O aumento do DPVar aumentou o DMV, o Dv90, o SPAN e a porcentagem do volume pulverizado composta por gotas maiores que 600 &#956;m, em contrapartida reduziu a porcentagem do volume pulverizado composta por gotas com diâmetro entre 100 e 200 &#956;m, entre 200 e 300 &#956;m, entre 300 e 400 &#956;m, entre 400 e 500 &#956;m e entre 500 e 600 &#956;m. Mesmo obedecendo às condições climáticas recomendadas para a aplicação de agrotóxicos, houve perda do volume aplicado por evaporação. Para a ponta LD 11002 e pressão de trabalho de 300 kPa, a perda de agrotóxicos por evaporação pode alcançar 27 % aproximadamente sob condições meteorológicas caracterizadas por baixa velocidade do ar, alta temperatura e baixa umidade relativa do ar.
170

Espectro de gotas geradas por ponta de jato plano de impacto para aplicação aérea na presença de adjuvantes em caldas de pulverização / Droplet spectra generated by deflection flat fan nozzles to aerial application witch adjuvants in spray solutions

Berna, Raquel [UNESP] 24 February 2017 (has links)
Submitted by RAQUEL BERNA null (raquelberna@fca.unesp.br) on 2017-06-06T20:47:10Z No. of bitstreams: 1 Dissertação RAQUEL BERNA-OK.pdf: 1253285 bytes, checksum: dc8e3d42748df8551595e20b82f9ce51 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-06-06T20:52:38Z (GMT) No. of bitstreams: 1 berna_r_me_bot.pdf: 1253285 bytes, checksum: dc8e3d42748df8551595e20b82f9ce51 (MD5) / Made available in DSpace on 2017-06-06T20:52:38Z (GMT). No. of bitstreams: 1 berna_r_me_bot.pdf: 1253285 bytes, checksum: dc8e3d42748df8551595e20b82f9ce51 (MD5) Previous issue date: 2017-02-24 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Por necessidade de maior capacidade de campo operacional durante as aplicações de produtos fitossanitários nas lavouras, a aviação agrícola têm se destacado como uma opção importante para diversas culturas. Porém, para garantir a eficácia da aplicação, alguns fatores devem ser considerados, como a calda, o elemento gerador de gotas e o fluxo de ar, pois estes irão influenciar no espectro de gotas formado e, consequentemente, no risco de ocorrer deriva. O objetivo desta pesquisa foi avaliar a influência de diferentes adjuvantes nas características físicas das caldas contendo fungicida, analisando-se o espectro de gotas formado em função de cada ângulo de deflexão de uma ponta de pulverização aérea CP-03, buscando um indicativo de utilização dessas técnicas quanto à qualidade e segurança das aplicações. Foram avaliadas quatro caldas, sendo uma calda com fungicida, e outras três com as misturas do fungicida com cada um dos adjuvantes: um multifuncional; um óleo vegetal; e um óleo mineral. A aplicação aérea foi simulada através de um ventilador de alta capacidade, com velocidade média de vento de 180 km h-1. Na saída deste ventilador foi acoplada a ponta de pulverização CP-03, e a pulverização foi simulada com taxa de aplicação de 20 L ha-1 e pressão de 200 kPa. Todas as caldas foram pulverizadas com os três ângulos defletores da ponta (30°, 55° e 90°) e o espectro de gotas foi determinado utilizando-se um equipamento analisador de partículas em tempo real posicionado na frente do simulador (VisiSizer portátil - Oxford Lasers Ltd / UK). Entre as caldas que continham o fungicida mais um dos adjuvantes, a calda composta pelo fungicida e o adjuvante multifuncional apresentou os maiores valores de diâmetro mediano volumétrico (DMV) e menores valores percentuais de gotas menores que 100 µm (V100), com todos os ângulos defletores da ponta de pulverização CP-03, posicionando-se como melhor técnica de redução de deriva. A adição de óleo mineral a calda proporcionou o menor valor de DMV e maior valor de V100, quando comparado às outras caldas. Com relação ao potencial de redução do risco de deriva o ângulo defletor de 30°, ofereceu o melhor potencial com todas as caldas avaliadas. / Due to the necessary of a greater operational efficiency during applications of plant health products in crops, agricultural aviation has been an important option for several crops. However, to ensure the effectiveness of the application, some factors must be considered as the spray formulation, the nozzles and the air flow, as these will influence the droplet spectrum formed and, consequently, the risk of spray drift. Based on this subject, the objective of this research was to evaluate the influence of different adjuvants on the physical characteristics of the spray mixture with the behavior of the droplet spectrum formed as a function of each deflection angle of the aerial spray tip CP-03 and to find an indicative of which of them are more suitable for reducing the risk of spray drift. Four spray formulations were evaluated, one spray solution with fungicide, and the other three sprays with a mix of each of the adjuvants containing fungicide, the first one surfactant, the second one mineral oil and the third one a vegetable oil. The aerial application was simulated through a high capacity fan with a high‐speed airstreams of 180 km h-1 . At the outlet of this fan the spray tip CP-03 was coupled, and the spraying was simulated with application rate of 20 L ha -1 and pressure of 200 kPa. All spray formulations were tested by three deflecting angles (30 °, 55 ° and 90 °) and the droplet spectrum was determined using a real-time particle analyzer positioned in front of the simulator (VisiSizer portable - Oxford Lasers Ltd / UK). Between the mixture that contained the fungicide over one of the adjuvants, the mix made by the fungicide and the adjuvant-one presented the highest values of volumetric medianum diameter (VDM) and lower percentage values of droplets smaller than 100 µm (V100), with all deflecting angles tip CP-03, positioning itself as the best technique of reducing spray drift. The addition of mineral oil the mix provided the lowest value of VDM and greater value of V100, when compared to the other mixture. With respect to the potential for reducing the risk of spray drift the deflector angle of 30°, offered the best potential with all the evaluated.

Page generated in 0.025 seconds