Comparação dos valores da pressão intraocular obtidos com diferentes tonômetros e suas correlações com dados biométricos oculares no glaucoma congênito / Comparison between intraocular pressure obtained with different tonometers and their correlations with biometric parameters in congenital glaucoma

Mendes, Marcio Henrique 01 November 2013 (has links)
OBJETIVOS: Comparar os valores da pressão intraocular (PIO), obtidos por intermédio do tonômetro de Perkins (TPK), tonômetro de contorno dinâmico Pascal (TCD) e Tono-Pen (TNP), confrontando-os com o tonômetro de aplanação de Goldmann (TAG), e correlacionar seus valores tonométricos com parâmetros biométricos oculares em pacientes portadores de glaucoma congênito primário. MÉTODOS: Estudo prospectivo, transversal, com inclusão de 46 pacientes (46 olhos) com diagnóstico de glaucoma congênito primário, com idades entre 12 e 40 anos, após obtenção do Termo de Consentimento Livre e Esclarecido. Todos os olhos estudados foram submetidos à tonometria ocular usando os tonômetros de Goldmann, de Perkins, o Tono-Pen e o tonômetro de contorno dinâmico Pascal. A ordem das tonometrias foi aleatória e o tonômetro de Goldmann foi adotado como padrão ouro. Os parâmetros biométricos estudados foram a curvatura (medida pela ceratometria), a espessura central da córnea (paquimetria), o diâmetro corneal (medido por meio de compasso cirúrgico) e o comprimento axial do olho foi obtido pela biometria ultrassônica. As distribuições dos parâmetros biométricos, assim como das tonometrias foram plotadas e analisadas conforme teste de Kolmogorov-Smirnov para aceitação de normalidade. O teste t de Student pareado para amostras independentes foi empregado para comparar as médias tonométricas de cada tonômetro com o padrão ouro. As correlações entre os parâmetros biométricos e as tonometrias foram realizadas através do coeficiente de correlação de Pearson e gráficos de regressão linear. O mesmo procedimento foi feito entre os parâmetros biométricos e as diferenças entre as três distintas tonometrias e a TAG. A concordância entre os tonômetros Perkins, Pascal e Tono-Pen e o de Goldamnn foi realizada pelo teste de concordância de correlação (CCC) e graficamente pelo método de Bland-Altman. O valor de corte de 2 mmHg foi adotado para avaliar a empregabilidade clínica desses tonômetros em pacientes semelhantes aos da amostra. RESULTADOS: O teste de Kolmogorov-Smirnov indicou aceitação da normalidade para todas as distribuições estudadas (TAG, TPK, TCD, TNP, Diâmetros corneal e axial, ceratometria média e paquimetria). Os momentos de correlação de Pearson empregados para realizar estudo das correlações entre os parâmetros biométricos e cada tonometria foram estatisticamente não significativos. As correlações entre os parâmetros biométricos e as diferenças entre tonometrias em relação ao TAG não apresentaram significância em sua maioria, sendo a única exceção a correlação moderada entre a diferença do TAG e o Tono-Pen versus a ceratometria média. No entanto, o coeficiente de determinação evidenciou influência modesta da ceratometria nessas diferenças (r² = 0,16; p = 0,004). O teste t de Student pareado demonstrou diferença significativa entre o TAG e o TP (p < 0,001). A diferença não foi significativa entre o TAG e o Pascal (p = 0.30), ou entre o TAG e o Tono-Pen (p = 0.68). Houve excelente concordância entre o TAG e o TP (CCC = 0,98; intervalo de confiança 95% (IC95%) = 0,97 - 0,99), já entre o TAG e o Pascal (CCC = 0,89; IC95% = 0,82 - 0,94) e entre o TAG e o Tono-Pen (CCC = 0,92; IC95% = 0,87 - 0,95). O gráfico tipo Bland-Altman TAG x Perkins demonstrou diferença média de 0,47 mmHg com intervalo de 95% (I95%) situado entre -0,98 e 1,92 mmHg. A dispersão das diferenças seguiu caráter aleatório. Os outros dois tonômetros também tiveram suas dispersões em caráter aleatório. TAG em relação ao tonômetro de Pascal apresentou diferença média de -0,3 mmHg (I95% = -4,2 a 3,6 mmHg). A diferença média do TAG em relação ao Tono-Pen foi de -0,1 mmHg (I95% = -3,7 a 3,5 mmHg). Em 21% dos pacientes, o tonômetro de Pascal apresentou diferenças maiores de 2 mmHg em relação ao TAG, ao passo que no Tono- Pen essa proporção foi de 17,3%, e o tonômetro de Perkins não apresentou em nenhum dos pacientes diferenças maiores que estes limites. CONCLUSÕES: A ceratometria, paquimetria e os diâmetros axial e corneal não se correlacionaram com a PIO obtida por meio do TAG, tonômetro de Perkins, Pascal ou Tono-Pen. As diferenças tonométricas entre TAG (padrão ouro) e os outros tonômetros também não se correlacionaram com esses parâmetros biométricos, com exceção da ceratometria média, que se correlacionou positiva e moderadamente com a diferença da PIO entre TAG e Tono-Pen. O tonômetro de Perkins apresentou concordância substancial com o TAG, já o Tono-Pen e o TCD apresentaram concordâncias moderadas, sendo a concordância do Tono-Pen maior que a do TCD / OBJECTIVES: To compare the values of intraocular pressure (IOP) obtained by Perkins tonometer (PKT), Pascal dynamic contour tonometer (DCT) and Tono-Pen (TP), comparing then with Goldmann applanation tonometry (GAT), analyzing their correlations with ocular biometric parameters in patients with primary congenital glaucoma. METHODS: Prospective and cross-sectional study, including 46 patients (46 eyes) diagnosed with primary congenital glaucoma, between 12 and 40 years old, after obtaining informed consent. Keratometry was performed, followed by Goldmann applanation tonometry, Perkins tonometry, DCT and TP. The order of tonometries was randomized. The Goldmann tonometer was adopted as the gold standard. Ultrasound pachymetry, ultrasound biometry and corneal diameter measurement with surgical compass were also performed. The distributions of biometric parameters, as well as the tonometries were plotted and analyzed using Kolmogorov-Smirnov for acceptance of normality. Paired Student\'s t test for independent samples was used to compare the means of each tonometry with the gold standard. The correlations between biometric parameters and tonometries were performed by Pearson\'s product moment correlation coefficient and linear regression plots. The same procedure was done between biometric parameters and the differences between the three distinct tonometries and Goldmann tonometry. The agreement between tonometers and the GAT was performed through concordance correlation coefficient (CCC) and graphically by the Bland-Altman method. End point of 2 mmHg was adopted to evaluate clinical employability of these tonometers in patients with similar conditions. RESULTS: The Kolmogorov-Smirnov indicated acceptance of normality for all distributions studied (GAT, PKT, DCT, TP, corneal diameter, axial length, keratometry and pachymetry). All the Pearson´s product moment correlation coefficients between biometric parameters and each tonometry were not significant. The correlations between the biometric parameters and the differences between tonometries compared to the gold standard were not significant in most cases. The only exception was a positive and moderate correlation between the difference of the GAT and Tono-Pen versus the keratometry. The determintation coefficient revealed a considerable, but no large influence of K on the differences between GAT and Tono-Pen (r² = 0.16; p = 0.004). Student\'s paired t test showed a significant difference between GAT and PT (p < 0.001). The difference was not significant between the GAT and Pascal (p = 0.30), or between the GAT and Tono-Pen (p = 0.68). There was excellent agreement between GAT and PT (CCC = 0.98, 95% confidence interval (95% CI) = 0.97 to 0.99), as between GAT and Pascal (CCC = 0.90, 95% CI = 0.82 to 0.94) and between GAT and Tono-Pen (CCC = 0.92, 95% CI = .87 to .95). Bland-Altman plot GAT x Perkins showed a mean difference of 0, 47 mmHg with 95% CI located between -0.98 and 1.92 mmHg. The distribution of the IOP differences was aleatory. The other two differences` distributions also had aleatory characteristics. When comparing GAT with Pascal, the mean difference was -0.3 mmHg (95% CI = -4.2% to 3.6 mmHg). Mean difference between GAT and Tono-Pen was -0.1 mmHg (95% CI = -3,7 to 3.5 mmHg). Pascal tonometer showed a difference greater than 2 mmHg comparing to GAT in 21% of the patients, while with Tono-Pen this ratio was 17.3% and the Perkins tonometer did not present in any patient differences greater than these limits. CONCLUSIONS: The keratometry, pachymetry, corneal diameter and axial length did not correlate with IOP obtained by GAT, Perkins tonometer, Tono-Pen or Pascal. The differences between GAT (gold standard) and the other tonometers also did not correlate with these biometric parameters, with the exception of corneal curvature, which was positive and moderately correlated with the difference in IOP between GAT and Tono-Pen. GAT and Perkins tonometer showed substantial agreement, although Tono-Pen and DCT showed moderate agreement with GAT. The concordance obtained with Tono-Pen was higher than the concordance obtained with DCT
12

Comparação dos valores da pressão intraocular obtidos com diferentes tonômetros e suas correlações com dados biométricos oculares no glaucoma congênito / Comparison between intraocular pressure obtained with different tonometers and their correlations with biometric parameters in congenital glaucoma

Marcio Henrique Mendes 01 November 2013 (has links)
OBJETIVOS: Comparar os valores da pressão intraocular (PIO), obtidos por intermédio do tonômetro de Perkins (TPK), tonômetro de contorno dinâmico Pascal (TCD) e Tono-Pen (TNP), confrontando-os com o tonômetro de aplanação de Goldmann (TAG), e correlacionar seus valores tonométricos com parâmetros biométricos oculares em pacientes portadores de glaucoma congênito primário. MÉTODOS: Estudo prospectivo, transversal, com inclusão de 46 pacientes (46 olhos) com diagnóstico de glaucoma congênito primário, com idades entre 12 e 40 anos, após obtenção do Termo de Consentimento Livre e Esclarecido. Todos os olhos estudados foram submetidos à tonometria ocular usando os tonômetros de Goldmann, de Perkins, o Tono-Pen e o tonômetro de contorno dinâmico Pascal. A ordem das tonometrias foi aleatória e o tonômetro de Goldmann foi adotado como padrão ouro. Os parâmetros biométricos estudados foram a curvatura (medida pela ceratometria), a espessura central da córnea (paquimetria), o diâmetro corneal (medido por meio de compasso cirúrgico) e o comprimento axial do olho foi obtido pela biometria ultrassônica. As distribuições dos parâmetros biométricos, assim como das tonometrias foram plotadas e analisadas conforme teste de Kolmogorov-Smirnov para aceitação de normalidade. O teste t de Student pareado para amostras independentes foi empregado para comparar as médias tonométricas de cada tonômetro com o padrão ouro. As correlações entre os parâmetros biométricos e as tonometrias foram realizadas através do coeficiente de correlação de Pearson e gráficos de regressão linear. O mesmo procedimento foi feito entre os parâmetros biométricos e as diferenças entre as três distintas tonometrias e a TAG. A concordância entre os tonômetros Perkins, Pascal e Tono-Pen e o de Goldamnn foi realizada pelo teste de concordância de correlação (CCC) e graficamente pelo método de Bland-Altman. O valor de corte de 2 mmHg foi adotado para avaliar a empregabilidade clínica desses tonômetros em pacientes semelhantes aos da amostra. RESULTADOS: O teste de Kolmogorov-Smirnov indicou aceitação da normalidade para todas as distribuições estudadas (TAG, TPK, TCD, TNP, Diâmetros corneal e axial, ceratometria média e paquimetria). Os momentos de correlação de Pearson empregados para realizar estudo das correlações entre os parâmetros biométricos e cada tonometria foram estatisticamente não significativos. As correlações entre os parâmetros biométricos e as diferenças entre tonometrias em relação ao TAG não apresentaram significância em sua maioria, sendo a única exceção a correlação moderada entre a diferença do TAG e o Tono-Pen versus a ceratometria média. No entanto, o coeficiente de determinação evidenciou influência modesta da ceratometria nessas diferenças (r² = 0,16; p = 0,004). O teste t de Student pareado demonstrou diferença significativa entre o TAG e o TP (p < 0,001). A diferença não foi significativa entre o TAG e o Pascal (p = 0.30), ou entre o TAG e o Tono-Pen (p = 0.68). Houve excelente concordância entre o TAG e o TP (CCC = 0,98; intervalo de confiança 95% (IC95%) = 0,97 - 0,99), já entre o TAG e o Pascal (CCC = 0,89; IC95% = 0,82 - 0,94) e entre o TAG e o Tono-Pen (CCC = 0,92; IC95% = 0,87 - 0,95). O gráfico tipo Bland-Altman TAG x Perkins demonstrou diferença média de 0,47 mmHg com intervalo de 95% (I95%) situado entre -0,98 e 1,92 mmHg. A dispersão das diferenças seguiu caráter aleatório. Os outros dois tonômetros também tiveram suas dispersões em caráter aleatório. TAG em relação ao tonômetro de Pascal apresentou diferença média de -0,3 mmHg (I95% = -4,2 a 3,6 mmHg). A diferença média do TAG em relação ao Tono-Pen foi de -0,1 mmHg (I95% = -3,7 a 3,5 mmHg). Em 21% dos pacientes, o tonômetro de Pascal apresentou diferenças maiores de 2 mmHg em relação ao TAG, ao passo que no Tono- Pen essa proporção foi de 17,3%, e o tonômetro de Perkins não apresentou em nenhum dos pacientes diferenças maiores que estes limites. CONCLUSÕES: A ceratometria, paquimetria e os diâmetros axial e corneal não se correlacionaram com a PIO obtida por meio do TAG, tonômetro de Perkins, Pascal ou Tono-Pen. As diferenças tonométricas entre TAG (padrão ouro) e os outros tonômetros também não se correlacionaram com esses parâmetros biométricos, com exceção da ceratometria média, que se correlacionou positiva e moderadamente com a diferença da PIO entre TAG e Tono-Pen. O tonômetro de Perkins apresentou concordância substancial com o TAG, já o Tono-Pen e o TCD apresentaram concordâncias moderadas, sendo a concordância do Tono-Pen maior que a do TCD / OBJECTIVES: To compare the values of intraocular pressure (IOP) obtained by Perkins tonometer (PKT), Pascal dynamic contour tonometer (DCT) and Tono-Pen (TP), comparing then with Goldmann applanation tonometry (GAT), analyzing their correlations with ocular biometric parameters in patients with primary congenital glaucoma. METHODS: Prospective and cross-sectional study, including 46 patients (46 eyes) diagnosed with primary congenital glaucoma, between 12 and 40 years old, after obtaining informed consent. Keratometry was performed, followed by Goldmann applanation tonometry, Perkins tonometry, DCT and TP. The order of tonometries was randomized. The Goldmann tonometer was adopted as the gold standard. Ultrasound pachymetry, ultrasound biometry and corneal diameter measurement with surgical compass were also performed. The distributions of biometric parameters, as well as the tonometries were plotted and analyzed using Kolmogorov-Smirnov for acceptance of normality. Paired Student\'s t test for independent samples was used to compare the means of each tonometry with the gold standard. The correlations between biometric parameters and tonometries were performed by Pearson\'s product moment correlation coefficient and linear regression plots. The same procedure was done between biometric parameters and the differences between the three distinct tonometries and Goldmann tonometry. The agreement between tonometers and the GAT was performed through concordance correlation coefficient (CCC) and graphically by the Bland-Altman method. End point of 2 mmHg was adopted to evaluate clinical employability of these tonometers in patients with similar conditions. RESULTS: The Kolmogorov-Smirnov indicated acceptance of normality for all distributions studied (GAT, PKT, DCT, TP, corneal diameter, axial length, keratometry and pachymetry). All the Pearson´s product moment correlation coefficients between biometric parameters and each tonometry were not significant. The correlations between the biometric parameters and the differences between tonometries compared to the gold standard were not significant in most cases. The only exception was a positive and moderate correlation between the difference of the GAT and Tono-Pen versus the keratometry. The determintation coefficient revealed a considerable, but no large influence of K on the differences between GAT and Tono-Pen (r² = 0.16; p = 0.004). Student\'s paired t test showed a significant difference between GAT and PT (p < 0.001). The difference was not significant between the GAT and Pascal (p = 0.30), or between the GAT and Tono-Pen (p = 0.68). There was excellent agreement between GAT and PT (CCC = 0.98, 95% confidence interval (95% CI) = 0.97 to 0.99), as between GAT and Pascal (CCC = 0.90, 95% CI = 0.82 to 0.94) and between GAT and Tono-Pen (CCC = 0.92, 95% CI = .87 to .95). Bland-Altman plot GAT x Perkins showed a mean difference of 0, 47 mmHg with 95% CI located between -0.98 and 1.92 mmHg. The distribution of the IOP differences was aleatory. The other two differences` distributions also had aleatory characteristics. When comparing GAT with Pascal, the mean difference was -0.3 mmHg (95% CI = -4.2% to 3.6 mmHg). Mean difference between GAT and Tono-Pen was -0.1 mmHg (95% CI = -3,7 to 3.5 mmHg). Pascal tonometer showed a difference greater than 2 mmHg comparing to GAT in 21% of the patients, while with Tono-Pen this ratio was 17.3% and the Perkins tonometer did not present in any patient differences greater than these limits. CONCLUSIONS: The keratometry, pachymetry, corneal diameter and axial length did not correlate with IOP obtained by GAT, Perkins tonometer, Tono-Pen or Pascal. The differences between GAT (gold standard) and the other tonometers also did not correlate with these biometric parameters, with the exception of corneal curvature, which was positive and moderately correlated with the difference in IOP between GAT and Tono-Pen. GAT and Perkins tonometer showed substantial agreement, although Tono-Pen and DCT showed moderate agreement with GAT. The concordance obtained with Tono-Pen was higher than the concordance obtained with DCT
13

Alterações biomecânicas da córnea de suínos induzidas pela confecções de lamelas pediculadas de diferentes espessuras por laser de femtossegundo / Biomechanical changes after flap creation with different thicknesses with the femtosecond laser in swinish cornea

Fabricio Witzel de Medeiros 22 July 2011 (has links)
Objetivo: Investigar as alterações biomecânicas da córnea de suínos induzidas pela confecção de lamelas pediculadas de diferentes espessuras pelo laser de femtossegundo. Métodos: Para a formação dos dois grupos, 12 olhos de porcos foram usados: lamelas pediculadas de 100 e de 300 micrômetros confeccionadas pelo laser de femtossegundo. Cada olho foi submetido aos seguintes exames, antes da criação das lamelas: topografia por rasterstereography, Ocular Response Analyzer (ORA), tomografia do segmento anterior por coerência óptica para a avaliação paquimétrica corneal e das lamelas criadas e sistema de velocidade de onda (SVO), que mede a velocidade de propagação de ondas acústicas entre dois transdutores posicionados na superfície corneal antes e imediatamente, após a feitura da lamela. O primerio passo foi desenhado para o estudo das diferenças em relação à histerese corneal, fator de resistência corneal, mudanças na curvatura e velocidade de propagação de onda acústica entre córneas com lamelas finas e espessas. Posteriormente, as lamelas foram amputadas, e as medidas do sistema de velocidade de onda foram repetidas. Resultados: A média de espessura das lamelas ± desviopadrão (DP) foi de 108,5±6,9 (8,5% da espessura total) e 307,8±11,5 m (22,9% da espessura total), para os grupos de lamelas finas e espessas, respectivamente (p< 0,001). Histerese corneal e o fator de resistência corneal não apresentaram diferença estatística, após a criação de lamelas finas (p = 0,81 e p = 0,62, respectivamente). Histerese corneal foi significantemente mais baixa, depois da confecção de lamelas mais espessas (8,0±1,0 para 5,1±1,5 mmHg para medidas pré e pós-operatórias, respectivamente, p = 0,003, diminuição de 36,25%) e fator de resistência corneal também mostrou significante diminuição nesse grupo, após o procedimento cirúrgico; valores médios pré e pós-operatórios de 8,2±1,6 e 4,1±2,5 mmHg respectivamente (p= 0,007), diminuição de 50%. A ceratometria média simulada apresentou maiores valores, após a confecção das lamelas mais espessas em relação ao pré-operatório (ceratometria pré e pós-operatória de 39,5±1 D e 45,9±1,2 D, respectivamente, p= 0,003). Para o grupo de lamelas finas, não houve diferença estatisticamente significante (ceratometria pré e pós-operatória de 40,6±0,6 D e 41,4±1,0 D, respectivamente, p=0,55). Em relação ao Sistema de Velocidade de Onda, após a criação das lamelas e sua amputação, houve diminuição da velocidade de propagação acústica, embora na maior parte das posições não fosse estatisticamente significante. Conclusão: Nas condições experimentais estabelecidas por este estudo, a criação de lamelas de maior espessura pareceu exercer efeito mais relevante sobre a biomecânica da córnea de suínos / Purpose: To study the impact of programmed flaps at two different thicknesses on the biomechanical properties of the swine corneas. Methods: Twelve pig eyes were enrolled in this study and were formed two groups: 100m and 300 m flaps performed with the femtosecond laser. Each eye had the following procedure before the flap creation: raster photograph topographic maps, Ocular Response Analyzer (ORA), Optical Coherence Tomography to measure the pachymetry and flap thickness and Surface Wave Velocity system which is a prototype system that measures sonic wave propagation time between two transducers positioned on the corneal surface before and after flap creation. This first step was designed to investigate the differences in respect to corneal hysteresis, corneal resistance factor, curvature change and ultrasonic wave propagation between the groups with thinner and thicker flaps. After this initial procedure, flap amputation was performed and new measurements with the surface wave velocity system were taken again. Results: Measured flap thicknesses averaged 108.5±6.9 (8.5% of the total cornea) and 307.8±11.5 m (22.9% of the total cornea) for thin and thick flap groups, respectively (p< 0.001). Hysteresis and corneal resistance factor did not change significantly after flap creation in the thin flap group (p = 0.81 and p = 0.62, respectively). With thicker flaps, both parameters decreased significantly from 8.0±1.0 to 5.1±1.5 mmHg (p=0.003, reduction of 36.25%) and from 8.2±1.6 to 4.1±2.5 mmHg, respectively (p = 0.007), reduction of 50%. Simulated keratometry values increased in the thick flap group (from 39.5±1 D to 45.9±1.2 D, p=0.003) after flap creation and not in the thin flap group (from 40.6±0.6D to 41.4±1.0D, p= 0.55). Regarding surface wave velocity analysis, the surgical procedures induced lower values in some positions although most of them did not present statistically different results. Conclusion: In this experimental model, thicker flaps seemed to have a greater effect on the biomechanics of the swinish cornea
14

Alterações biomecânicas da córnea de suínos induzidas pela confecções de lamelas pediculadas de diferentes espessuras por laser de femtossegundo / Biomechanical changes after flap creation with different thicknesses with the femtosecond laser in swinish cornea

Medeiros, Fabricio Witzel de 22 July 2011 (has links)
Objetivo: Investigar as alterações biomecânicas da córnea de suínos induzidas pela confecção de lamelas pediculadas de diferentes espessuras pelo laser de femtossegundo. Métodos: Para a formação dos dois grupos, 12 olhos de porcos foram usados: lamelas pediculadas de 100 e de 300 micrômetros confeccionadas pelo laser de femtossegundo. Cada olho foi submetido aos seguintes exames, antes da criação das lamelas: topografia por rasterstereography, Ocular Response Analyzer (ORA), tomografia do segmento anterior por coerência óptica para a avaliação paquimétrica corneal e das lamelas criadas e sistema de velocidade de onda (SVO), que mede a velocidade de propagação de ondas acústicas entre dois transdutores posicionados na superfície corneal antes e imediatamente, após a feitura da lamela. O primerio passo foi desenhado para o estudo das diferenças em relação à histerese corneal, fator de resistência corneal, mudanças na curvatura e velocidade de propagação de onda acústica entre córneas com lamelas finas e espessas. Posteriormente, as lamelas foram amputadas, e as medidas do sistema de velocidade de onda foram repetidas. Resultados: A média de espessura das lamelas ± desviopadrão (DP) foi de 108,5±6,9 (8,5% da espessura total) e 307,8±11,5 m (22,9% da espessura total), para os grupos de lamelas finas e espessas, respectivamente (p< 0,001). Histerese corneal e o fator de resistência corneal não apresentaram diferença estatística, após a criação de lamelas finas (p = 0,81 e p = 0,62, respectivamente). Histerese corneal foi significantemente mais baixa, depois da confecção de lamelas mais espessas (8,0±1,0 para 5,1±1,5 mmHg para medidas pré e pós-operatórias, respectivamente, p = 0,003, diminuição de 36,25%) e fator de resistência corneal também mostrou significante diminuição nesse grupo, após o procedimento cirúrgico; valores médios pré e pós-operatórios de 8,2±1,6 e 4,1±2,5 mmHg respectivamente (p= 0,007), diminuição de 50%. A ceratometria média simulada apresentou maiores valores, após a confecção das lamelas mais espessas em relação ao pré-operatório (ceratometria pré e pós-operatória de 39,5±1 D e 45,9±1,2 D, respectivamente, p= 0,003). Para o grupo de lamelas finas, não houve diferença estatisticamente significante (ceratometria pré e pós-operatória de 40,6±0,6 D e 41,4±1,0 D, respectivamente, p=0,55). Em relação ao Sistema de Velocidade de Onda, após a criação das lamelas e sua amputação, houve diminuição da velocidade de propagação acústica, embora na maior parte das posições não fosse estatisticamente significante. Conclusão: Nas condições experimentais estabelecidas por este estudo, a criação de lamelas de maior espessura pareceu exercer efeito mais relevante sobre a biomecânica da córnea de suínos / Purpose: To study the impact of programmed flaps at two different thicknesses on the biomechanical properties of the swine corneas. Methods: Twelve pig eyes were enrolled in this study and were formed two groups: 100m and 300 m flaps performed with the femtosecond laser. Each eye had the following procedure before the flap creation: raster photograph topographic maps, Ocular Response Analyzer (ORA), Optical Coherence Tomography to measure the pachymetry and flap thickness and Surface Wave Velocity system which is a prototype system that measures sonic wave propagation time between two transducers positioned on the corneal surface before and after flap creation. This first step was designed to investigate the differences in respect to corneal hysteresis, corneal resistance factor, curvature change and ultrasonic wave propagation between the groups with thinner and thicker flaps. After this initial procedure, flap amputation was performed and new measurements with the surface wave velocity system were taken again. Results: Measured flap thicknesses averaged 108.5±6.9 (8.5% of the total cornea) and 307.8±11.5 m (22.9% of the total cornea) for thin and thick flap groups, respectively (p< 0.001). Hysteresis and corneal resistance factor did not change significantly after flap creation in the thin flap group (p = 0.81 and p = 0.62, respectively). With thicker flaps, both parameters decreased significantly from 8.0±1.0 to 5.1±1.5 mmHg (p=0.003, reduction of 36.25%) and from 8.2±1.6 to 4.1±2.5 mmHg, respectively (p = 0.007), reduction of 50%. Simulated keratometry values increased in the thick flap group (from 39.5±1 D to 45.9±1.2 D, p=0.003) after flap creation and not in the thin flap group (from 40.6±0.6D to 41.4±1.0D, p= 0.55). Regarding surface wave velocity analysis, the surgical procedures induced lower values in some positions although most of them did not present statistically different results. Conclusion: In this experimental model, thicker flaps seemed to have a greater effect on the biomechanics of the swinish cornea
15

Fantomy pro oftalmologický ultrazvukový systém / Phantoms for ultrasound system in ophthalmology

Fabík, Vojtěch January 2013 (has links)
In our work we have studied the ultrasonic imaging systems and their use in ophthalmology, especially with the device Nidek 4000. We described ophthalmological examination methods. In addition, we are using the simulation program Field II. It simulated eye phantom and created his B-scan and biometry, where we compared the effects of different central frequency ultrasonic probes and different speeds of sound in the resulting values. We also created phantoms using agarose gel and materials of different properties. On phantoms, we studied the effect of the velocity of ultrasound in measurement results, effect of the concentration of the agarose gel to the velocity of sound. And we created phantoms simulating the human eye. Measurement protocol was created for use in teaching.
16

Měření vlastností oftalmologického ultrazvukového systému / Properties measurement of ultrasound system in ophthalmology

Grebíková, Lucie January 2014 (has links)
The thesis deals with physical principles of ultrasound with following specialization on ophtalmic ultrasound system Nidek Echoscan 4000 and its properties. And also it deals with description of investigative techniques in ophthalmology (A-mode, B-mode, biometry and pachymetry). Next, they was suggested procedures of measurement and that is spatial resolution (axial and lateral spatial resolution) and propagation speed of ultrasound depending on the temperature. Then these properties was tested on laboratory phantoms of eye – ETETECH LTD. and Multipurpose Ultrasound Phantom but on created phantoms of eye too, which will be made from agarose gel with build-in materail (fishing line, plastic film, plastic bag and rubber). At the end, measured values was processed in the generated program.