• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • Tagged with
  • 8
  • 8
  • 7
  • 6
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação de variáveis ambientais em ambientes destinados a ocupação comum

Corbi, Karina Ponsoni [UNESP] 18 August 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:20Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-08-18Bitstream added on 2014-06-13T20:16:31Z : No. of bitstreams: 1 corbi_kp_me_arafcf.pdf: 422770 bytes, checksum: 6a87a5e20c6db8ffd363817b89326bde (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Universidade Estadual Paulista (UNESP) / Os principais parâmetros de qualidade do ar de um ambiente naturalmente ventilado e outro climatizado, destinados a ocupação comum, foram analisados. As variáveis ambientais consideradas foram concentração de bactéria (UFC/m3 de ar), concentração de fungo (UFC/m3 de ar), taxa de CO2 (ppm), umidade relativa do ar (%), velocidade (Km/h), temperatura (ºC) e concentração de partículas (æg/m3 de ar). Nossos achados apontam que os parâmetros mais influenciados pela ocupação dos ambientes são taxa de CO2 e concentração de aerossóis bacterianos, porém os valores médios no ambiente ventilado foram menores que no climatizado. Em decorrência da utilização, cada vez mais freqüente, de sistemas de condicionamento do ar, esse trabalho visou colaborar com o conhecimento dos principais parâmetros de qualidade de ar em ambientes climatizados e naturalmente ventilados. Para que a boa qualidade do ar de interiores possa ser mantida, em ambientes onde a ventilação é constante, é imprescindível o controle do número de ocupantes. / The mainly environmentals parameters of the air quality in ventilatized and climatized ambients, destinated to the common occupation, were analyzed in this research. The evaluated environmental variables were the concentration of bacteria (CFU/m3 of air), concentration of fungo (CFU/m3 of air), rate of carbon dioxide (ppm), relative air humidity (%), speed (Km/h), temperature (ºC) and concentration of particles (æg/m3 of air). The correlation among the number of people, and the other variables, obtain significance, in the two samples, for the concentration of bacterial aerosols, CO2 rate and the temperature for the climatized ambient. In the ventilated ambient only the CO2 concentration and the number of people was correlated in the two samples.
2

Efeito dos parâmetros ambientais sobre a macroalga Gracilaria domingensis: estratégias de aclimatação e fotoproteção na espécie / Effects of environmental parameters on macroalgae Gracilaria domingensis: acclimation and photoprotection strategy on specie

Pereira, Dinaelza Castelo 31 October 2014 (has links)
Em seu habitat natural as algas estão sujeitas a ação simultânea de vários fatores, como radiação (fotossinteticamente ativa e ultravioleta), temperatura, salinidade e disponibilidade de nutrientes, entre outros. A variação desses fatores no ambiente natural ocorre de forma coletiva e uma rápida resposta do organismo é determinante pra sua sobrevivência. Neste trabalho foram conduzidos experimentos relacionados aos efeitos da variação nos parâmetros ambientais sobre a macroalga Gracilaria domingensis. Três linhagens cromáticas dessa espécie foram cultivadas no mar, em diferentes épocas do ano (estações chuvosa e seca). Os dados fotossintéticos e bioquímicos foram acessados em uma escala de tempo referente às variações observadas durante o período de luz do dia e em uma escala referente às variações observadas em semanas. Os resultados obtidos a partir de análises dos parâmetros fotossintéticos, conteúdo pigmentar, concentração de glutationa, concentração de aminoácidos tipo micosporina, conteúdo tecidual de carbono, nitrogênio e fósforo, teor de lipídeos e ácidos graxos e rendimento do ágar mostraram alterações no perfil bioquímico e fisiológico da macroalga. Essas alterações foram correlacionadas com os fatores abióticos e sugerem alterações no metabolismo como uma das estratégias de aclimatação da espécie. / In their natural habitat algae are exposed to simultaneous action of various factors, as radiation (photosynthetically active radiation and ultraviolet), temperature, salinity, nutrient availability and others. The variation in these factors in the natural environment occurs collectively and the algae capability for quick response is determinant for survival. In this work, studies related to the effects of environmental variation on the macroalgae Gracilaria domingensis were performed. Three chromatic strains were cultivated in the sea, at different times of the year (dry and rainy seasons). Biochemical and photosynthetic responses were accessed on a daylight time scale and on a week time scale. The reached results for photosynthetic parameters, pigment content, glutathione concentrations, mycosporine-like amino acids concentrations, carbon, nitrogen and phosphorus tissue content, lipids and fatty acids levels and agar yield, revealed the altered biochemical and physiological profile of macroalgae. These changes were environment related and suggest metabolism changes as a strategy used by this organism to acclimate.
3

Efeito dos parâmetros ambientais sobre a macroalga Gracilaria domingensis: estratégias de aclimatação e fotoproteção na espécie / Effects of environmental parameters on macroalgae Gracilaria domingensis: acclimation and photoprotection strategy on specie

Dinaelza Castelo Pereira 31 October 2014 (has links)
Em seu habitat natural as algas estão sujeitas a ação simultânea de vários fatores, como radiação (fotossinteticamente ativa e ultravioleta), temperatura, salinidade e disponibilidade de nutrientes, entre outros. A variação desses fatores no ambiente natural ocorre de forma coletiva e uma rápida resposta do organismo é determinante pra sua sobrevivência. Neste trabalho foram conduzidos experimentos relacionados aos efeitos da variação nos parâmetros ambientais sobre a macroalga Gracilaria domingensis. Três linhagens cromáticas dessa espécie foram cultivadas no mar, em diferentes épocas do ano (estações chuvosa e seca). Os dados fotossintéticos e bioquímicos foram acessados em uma escala de tempo referente às variações observadas durante o período de luz do dia e em uma escala referente às variações observadas em semanas. Os resultados obtidos a partir de análises dos parâmetros fotossintéticos, conteúdo pigmentar, concentração de glutationa, concentração de aminoácidos tipo micosporina, conteúdo tecidual de carbono, nitrogênio e fósforo, teor de lipídeos e ácidos graxos e rendimento do ágar mostraram alterações no perfil bioquímico e fisiológico da macroalga. Essas alterações foram correlacionadas com os fatores abióticos e sugerem alterações no metabolismo como uma das estratégias de aclimatação da espécie. / In their natural habitat algae are exposed to simultaneous action of various factors, as radiation (photosynthetically active radiation and ultraviolet), temperature, salinity, nutrient availability and others. The variation in these factors in the natural environment occurs collectively and the algae capability for quick response is determinant for survival. In this work, studies related to the effects of environmental variation on the macroalgae Gracilaria domingensis were performed. Three chromatic strains were cultivated in the sea, at different times of the year (dry and rainy seasons). Biochemical and photosynthetic responses were accessed on a daylight time scale and on a week time scale. The reached results for photosynthetic parameters, pigment content, glutathione concentrations, mycosporine-like amino acids concentrations, carbon, nitrogen and phosphorus tissue content, lipids and fatty acids levels and agar yield, revealed the altered biochemical and physiological profile of macroalgae. These changes were environment related and suggest metabolism changes as a strategy used by this organism to acclimate.
4

Desempenho exergético do corpo humano e de seu sistema respiratório em função de parâmetros ambientais e da intensidade de atividade física. / Exergy performance of the human body and its respiratory system as a function of environmental parameters and intensity of physical activity.

Henriques, Izabela Batista 23 August 2013 (has links)
A análise exergética é aplicada ao corpo humano a fim de determinar o comportamento exergético padrão do corpo e do seu sistema respiratório para um indivíduo saudável em diferentes condições ambientais e intensidades de atividade física. Para isso, são calculadas as taxas de exergia destruída e as eficiências exergéticas do pulmão e do corpo como um todo para diferentes altitudes, períodos de aclimatação, temperaturas, umidades relativas e intensidades de atividade física. São utilizados modelos do corpo e do sistema respiratório disponíveis na literatura, assim como um modelo exergético do corpo. Para a análise exergética do sistema respiratório é proposto um modelo exergético baseado no modelo de transferência de calor e massa presente na literatura. A análise exergética é aplicada a dois volumes de controle: o corpo e o sistema respiratório, que compreende as vias aéreas e os pulmões. No primeiro volume de controle ocorre transferência de exergia para o ambiente através de convecção e radiação, assim como fluxos de exergia através da respiração e evaporação, além da geração de exergia pelo metabolismo exergético. No volume de controle relativo ao sistema respiratório, os fluxos de exergia estão associados ao ar inspirado e expirado e ao sangue venoso e arterial. A transferência de exergia ocorre através do calor gerado pelo metabolismo e do trabalho dos músculos respiratórios. Há também uma variação da exergia relativa ao metabolismo exergético do pulmão. Os resultados obtidos indicam que a eficiência exergética do pulmão diminui com a altitude e atividade física, enquanto a do corpo aumenta para ambos os parâmetros. Com relação à aclimatação, o período no qual as eficiências exergéticas são máximas é a partir de vinte dias. No que diz respeito à variação da temperatura e da umidade relativa, observa-se que quanto maior a intensidade da atividade física, menor a temperatura próxima do conforto. Nota-se que as eficiências do corpo e do pulmão têm comportamentos distintos, sendo o corpo mais influenciado pela intensidade da atividade física, enquanto o sistema respiratório é mais suscetível a alterações das condições ambientais. / Exergy analysis is applied to human body in order to determine the exergy behavior pattern of the body and its respiratory system for a healthy subject under different environmental conditions and physical activity intensities. In order to do so, destroyed exergy rate and exergy efficiencies are calculated for different altitudes, acclimatization periods, temperatures, relative humidities and exercise intensities. An integrated model of the body and its respiratory system and an exergy model of the body are utilized. To perform the exergy analysis of respiratory system, an exergy model based on that available in literature is proposed. Exergy analysis is applied to two control volumes: the human body as a whole and the respiratory system, which comprises the lungs and the airways. In the first control volume, the exergy rate transferred to the environment due to convection and radiation is considered, as well as the exergy flow rate associated with respiration and transpiration and the internal exergy generation caused by the exergy metabolism. In the second one, the exergy rates and flow rates are associated with the venous blood and the inspired air in the inlet and the arterial blood and expired air in the outlet. An internal exergy variation due to the exergy metabolism of the lung, an exergy transfer associated with the metabolism of the lung and the work performed by the respiratory muscles were also taken into account. The results indicate that the exergy efficiency of the lung decreases as the altitude and exercise intensity increase, while the exergy efficiency of the body increases for both parameters. Regarding acclimatization period, the greatest exergy efficiencies are obtained after twenty days. Concerning temperature and humidity variations, the higher the activity level, the lower the thermal comfort temperature. It is also possible to observe distinct behaviors between body and lung. The body is more influenced by the physical activity intensity, while the respiratory system is more affected by environmental parameters.
5

Desempenho exergético do corpo humano e de seu sistema respiratório em função de parâmetros ambientais e da intensidade de atividade física. / Exergy performance of the human body and its respiratory system as a function of environmental parameters and intensity of physical activity.

Izabela Batista Henriques 23 August 2013 (has links)
A análise exergética é aplicada ao corpo humano a fim de determinar o comportamento exergético padrão do corpo e do seu sistema respiratório para um indivíduo saudável em diferentes condições ambientais e intensidades de atividade física. Para isso, são calculadas as taxas de exergia destruída e as eficiências exergéticas do pulmão e do corpo como um todo para diferentes altitudes, períodos de aclimatação, temperaturas, umidades relativas e intensidades de atividade física. São utilizados modelos do corpo e do sistema respiratório disponíveis na literatura, assim como um modelo exergético do corpo. Para a análise exergética do sistema respiratório é proposto um modelo exergético baseado no modelo de transferência de calor e massa presente na literatura. A análise exergética é aplicada a dois volumes de controle: o corpo e o sistema respiratório, que compreende as vias aéreas e os pulmões. No primeiro volume de controle ocorre transferência de exergia para o ambiente através de convecção e radiação, assim como fluxos de exergia através da respiração e evaporação, além da geração de exergia pelo metabolismo exergético. No volume de controle relativo ao sistema respiratório, os fluxos de exergia estão associados ao ar inspirado e expirado e ao sangue venoso e arterial. A transferência de exergia ocorre através do calor gerado pelo metabolismo e do trabalho dos músculos respiratórios. Há também uma variação da exergia relativa ao metabolismo exergético do pulmão. Os resultados obtidos indicam que a eficiência exergética do pulmão diminui com a altitude e atividade física, enquanto a do corpo aumenta para ambos os parâmetros. Com relação à aclimatação, o período no qual as eficiências exergéticas são máximas é a partir de vinte dias. No que diz respeito à variação da temperatura e da umidade relativa, observa-se que quanto maior a intensidade da atividade física, menor a temperatura próxima do conforto. Nota-se que as eficiências do corpo e do pulmão têm comportamentos distintos, sendo o corpo mais influenciado pela intensidade da atividade física, enquanto o sistema respiratório é mais suscetível a alterações das condições ambientais. / Exergy analysis is applied to human body in order to determine the exergy behavior pattern of the body and its respiratory system for a healthy subject under different environmental conditions and physical activity intensities. In order to do so, destroyed exergy rate and exergy efficiencies are calculated for different altitudes, acclimatization periods, temperatures, relative humidities and exercise intensities. An integrated model of the body and its respiratory system and an exergy model of the body are utilized. To perform the exergy analysis of respiratory system, an exergy model based on that available in literature is proposed. Exergy analysis is applied to two control volumes: the human body as a whole and the respiratory system, which comprises the lungs and the airways. In the first control volume, the exergy rate transferred to the environment due to convection and radiation is considered, as well as the exergy flow rate associated with respiration and transpiration and the internal exergy generation caused by the exergy metabolism. In the second one, the exergy rates and flow rates are associated with the venous blood and the inspired air in the inlet and the arterial blood and expired air in the outlet. An internal exergy variation due to the exergy metabolism of the lung, an exergy transfer associated with the metabolism of the lung and the work performed by the respiratory muscles were also taken into account. The results indicate that the exergy efficiency of the lung decreases as the altitude and exercise intensity increase, while the exergy efficiency of the body increases for both parameters. Regarding acclimatization period, the greatest exergy efficiencies are obtained after twenty days. Concerning temperature and humidity variations, the higher the activity level, the lower the thermal comfort temperature. It is also possible to observe distinct behaviors between body and lung. The body is more influenced by the physical activity intensity, while the respiratory system is more affected by environmental parameters.
6

A conservação preventiva de acervos arqueológicos em metal: uma análise sobre o Laboratório Multidisciplinar de Investigação Arqueológica – LÂMINA (ICH/UFPel)

Machado, Tiago Graule 21 August 2015 (has links)
Submitted by Leonardo Lima (leonardoperlim@gmail.com) on 2016-04-20T12:33:50Z No. of bitstreams: 2 A conservação preventiva de acervos arqueológicos em metal.pdf: 8959189 bytes, checksum: 2cea29f4d9ef58e01b483f7eede6a93e (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Aline Batista (alinehb.ufpel@gmail.com) on 2016-04-20T22:26:04Z (GMT) No. of bitstreams: 2 A conservação preventiva de acervos arqueológicos em metal.pdf: 8959189 bytes, checksum: 2cea29f4d9ef58e01b483f7eede6a93e (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Aline Batista (alinehb.ufpel@gmail.com) on 2016-04-20T22:28:17Z (GMT) No. of bitstreams: 2 A conservação preventiva de acervos arqueológicos em metal.pdf: 8959189 bytes, checksum: 2cea29f4d9ef58e01b483f7eede6a93e (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2016-04-20T22:28:44Z (GMT). No. of bitstreams: 2 A conservação preventiva de acervos arqueológicos em metal.pdf: 8959189 bytes, checksum: 2cea29f4d9ef58e01b483f7eede6a93e (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2015-08-21 / Sem bolsa / Atualmente, os estudos e pesquisas sobre conservação preventiva, referentes às coleções de cunho arqueológico, vêm ocupando espaços cada vez mais significativos nos mais variados fóruns de debates acadêmicos e tecnológicos, repercutindo assim no universo não só de laboratórios como de museus que lidam com arqueologia em todo país. São ações e medidas preventivas que operacionalizam estratégias para minimizar o inevitável processo de deterioração desses objetos, não só de sua materialidade, mas de tudo de intangível que possa estar relacionados a eles, permitindo recuperar o máximo de informação possível, as gerações atuais como vindouras. Este trabalho objetiva analisar as medidas de controle ambiental (luz, umidade relativa, temperatura e poluentes – material particulado e gases), que estão sendo adotadas nos acervos em metal pertencente ao Laboratório Multidisciplinar de Investigação Arqueológica (LÂMINA) do Instituto de Ciências Humanas (ICH) da Universidade Federal de Pelotas (UFPel), localizado na cidade de Pelotas-RS (Brasil). Foi empregada a seguinte metodologia: revisão bibliográfica e pesquisa documental; análise dos ambientes das coleções no Laboratório; análise do estado de conservação dos artefatos metálicos; comparação dos registros das medições ambientais realizadas no LÂMINA com as recomendações nacionais e internacionais. Parte-se da hipótese que as práticas de controle adequadas, que poderiam reduzir consideravelmente os riscos a que esse tipo de acervo está exposto, podem não estar sendo contemplada de uma forma totalmente satisfatória, frente aos danos imediatos desses bens culturais, consequentemente, inviabilizando informações valiosas para a interpretação da cultura material. / Currently, studies and research on preventive conservation of archaeological collections relating to nature, are occupying increasingly significant spaces in various forums of academic and technological debates, thereby impacting not only in the universe of laboratories as museums that deal with archeology throughout the country. Those are actions and preventive measures that operationalize strategies to minimize the inevitable process of deterioration of these objects not only of its materiality, but all the intangibles that might be related to them, allowing you to recover the maximum amount of information, both current and future generations. This work aims to analyze the environmental control measures (light, humidity, temperature and pollutants – particulate matter and gaseous) that are being adopted in the collections of metal belonging to the Multidisciplinary Laboratory of Archaeological Research (LÂMINA) Institute of Human Sciences (ICH), Federal University of Pelotas (UFPel), located in the city of Pelotas (Brazil). The methodology used was: literature review and desk research; analysis of the environments of the collections at the Laboratory; analysis of the state of conservation of metal artifacts; comparison of records of environmental easurements in BLADE with national and international recommendations. Part of the hypothesis is that the practices of proper control, that could significantly reduce the risks to which such assets are exposed, may not have been contemplated in a totally satisfactory manner, accelerating the elements responsible for the immediate damage of the cultural heritage.
7

Estudos dos parâmetros ambientais, químicos e mineralógicos dos agregados reciclados oriundos da construção civil

Silva, Viviane Rangel Gomes 31 March 2015 (has links)
Submitted by Maike Costa (maiksebas@gmail.com) on 2016-01-06T14:43:43Z No. of bitstreams: 1 arquivototal.pdf: 3084404 bytes, checksum: a557c23387b1239e1ed610d310cf09ee (MD5) / Made available in DSpace on 2016-01-06T14:43:43Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 3084404 bytes, checksum: a557c23387b1239e1ed610d310cf09ee (MD5) Previous issue date: 2015-03-31 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / This study aimed to analyze environmental, chemical and mineralogical parameters of Recycled Aggregates (RA), classified as Recycled Concrete Aggregate (RCA), generated at the Plant for Improvement of Construction Solid Waste (USIBEN), in João Pessoa / PB, as well as some Natural Aggregates (NA). Environmental analyses were performed, through solubilization and leaching tests, as well as the characterization of its chemical and mineralogical composition by X-ray fluorescence, X-ray diffraction, differential thermal and thermogravimetric analyses, and infrared spectrometry. In Step I, for the solubilized extract, the aggregates Gravel 12 RA, Gravel 25 RA, Fine Aggregate RA, Gravel 12 NA and Stone Dust NA had values above the limits set out in Annex G of the standard ABNT NBR Nº 10004/2004 for some chemical parameters, such as sulfate (250 mg / L), iron (0.30 mg / L) and aluminum (0.20 mg / L). This study also investigated the presence of heavy metals (As, Cd, Cr, Ni, Al, Cu, Fe, Ni, Se, Zn), and, in accordance with the aforementioned standard, Gravel 12 RA exceeded the allowable limit for Cadmium. According to these results, the aggregates mentioned above changed their classification from Class II B – Inert – to Class II A – Non-Inert. In Step II, only four aggregates were selected to continue the study: Sand NA and RA; Gravel 12 NA and RA. The pH behavior of the aggregates chosen was investigated, and all of them suffered decay, stabilizing at alkaline pH (pH> 7). The chemical and mineralogical analyses (XRF, XRD, DTA / TG and IV) revealed the presence of quartz (SiO2) in the four samples, being the greater quantity in the NA ones. It was confirmed that the RA samples had compounds also found in mortar and concrete, such as calcium carbonate (CaCO3), alumina (Al2O3), iron oxide (Fe2O3), magnesium oxide (MgO) and cement hydration products, such as portlandite [Ca(OH)2] and plaster [CaSO42H2O]. It was concluded that the RA studied are viable for several uses, in relation to environmental, chemical and mineralogical analyses, since most compounds found in them are also part of NA used daily in civil construction. / Este trabalho teve como objetivo analisar os parâmetros ambientais, químicos e mineralógicos de Agregados Reciclados (AR), classificados como Agregado Reciclado de Concreto (ARC), gerados na Usina de Beneficiamento de Resíduos Sólidos da Construção Civil (USIBEN) em João Pessoa/PB, como também alguns Agregados Naturais (AN). Foi realizada análise ambiental, através de ensaios de lixiviação e solubilização, bem como a caracterização da sua composição química e mineralógica, por fluorescência de raios X, difração de raios X, análise térmica diferencial e termogravimétrica e espectrometria de infravermelho. Na Etapa I, para o extrato solubilizado, os agregados brita 12 AR, brita 25 AR, agregado miúdo AR, brita 12 AN e pó de pedra AN apresentaram valores superiores ao limite definido no anexo G da ABNT NBR Nº 10004/2004 para alguns parâmetros químicos como sulfato (250 mg/L), ferro (0,30 mg/L) e alumínio (0,20 mg/L). Também investigou-se a presença de metais pesados (As, Cd, Pb, Cr, Ni, Al, Cu, Fe, Ni, Se, Zn) e de acordo com a referida norma, a brita 12 AR ultrapassou o limite permitido para o metal cádmio. De acordo com esses resultados, os agregados supracitados mudam sua classificação de Classe II B - Inertes, para Classe II A - não Inertes. Na Etapa II foram definidos apenas 4 agregados para continuidade: areia AN e AR; brita 12 AN e AR. Investigou-se o comportamento do pH dos 4 agregados e todos tiveram decaimento, estabilizando-se em pH alcalino (pH > 7). Para as análises químicas e mineralógicas (FRX, DRX, DTA/TG e IV) observou-se a presença de quartzo (SiO2) nas 4 amostras sendo em maior quantidade nos AN. Para as amostras AR foram comprovadas a presença de compostos presentes em argamassa e concreto, como carbonato de cálcio (CaCO3), alumina (Al2O3), óxido de ferro (Fe2O3), óxido de magnésio (MgO) e produtos da hidratação do cimento, como a portlandita [Ca(OH)2] e gesso [CaSO42H2O]. Portanto os AR estudados são viáveis em relação a análise ambiental, química e mineralógica, para diversas utilizações, pois a maioria dos compostos encontrados neles também fazem parte dos AN, usados diariamente na construção civil.
8

Tratamento de efluente da indústria de cosméticos via reagente de Fenton e adsorção / Cosmetic wastewater treatment by Fenton’s reagent and adsorption

Pereira, Lisiée Manzoli Gonçaves 04 April 2018 (has links)
Submitted by Liliane Ferreira (ljuvencia30@gmail.com) on 2018-05-08T15:23:51Z No. of bitstreams: 2 Dissertação - Lisiée Manzoli Gonçaves Pereira - 2018.pdf: 2364960 bytes, checksum: 8549e395821c153662fa074784ea0915 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2018-05-09T11:25:05Z (GMT) No. of bitstreams: 2 Dissertação - Lisiée Manzoli Gonçaves Pereira - 2018.pdf: 2364960 bytes, checksum: 8549e395821c153662fa074784ea0915 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-05-09T11:25:05Z (GMT). No. of bitstreams: 2 Dissertação - Lisiée Manzoli Gonçaves Pereira - 2018.pdf: 2364960 bytes, checksum: 8549e395821c153662fa074784ea0915 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-04-04 / Fundação de Amparo à Pesquisa do Estado de Goiás - FAPEG / The effluent generated by the cosmetic industries, from industrial processes, tank washes and disposal of failed batches, are highly recalcitrant due to their complex chemical composition. The deposition of such liquids into water bodies must follow a series of environmental parameter values established by local and federal legislation so that they do not negatively affect the receiving environment and its ecosystems. Traditional wastewater treatment methods sometimes fail to satisfactorily remove their contaminating potential. Therefore, this work aims at integrating two treatment technologies, Fenton’s reagent and adsorption, in order to achieve maximum removal efficiency in the values of environmental and water quality control parameters. Wastewater from a cosmetics industry in the metropolitan area of Goiania (state of Goias, Brazil) was used as object of this study. The environmental parameters analyzed were: color (via absorbance analysis), total iron, organic matter (via chemical oxygem demand analysis), total phenols, pH, turbidity, conductivity, dissolved oxygen, initial and residual H2O2 and total solids. They were analyzed on the pretreated wastewater, after the Fenton’s reagent treatment, after adsorption, and after the combined processes. The adsorbent was characterized by elemental analysis (CHN), thermogravimetry (TG/DTA), adsorption and desorption of N2 and infrared spectroscopy. In the Fenton’s reagent treatment, factorial design 23 was performed for the factors: Fe2+ and H2O2 concentrations and pH, in order to outline the process parameters. From these data, other Fenton assays were performed by opening Fe2+, H2O2 and pH concentration bands to evaluate their influence on the removal of the environmental parameters mentioned above. The best results were obtained in Fe2+ 184.21 mg L-1; H2O2 concentration at 1300 mg L-1, and pH at 3.5. Subsequently, the wastewater treated via Fenton’s reagent was subjected to the adsorption process, in which seven types of activated carbon were tested. The activated charcoal which presented the best efficiency at removing environmental parameter values was submitted to kinetic tests at different temperatures and contact times. The equilibrium time was reached in 16 minutes (tested in the range of 4min to 24h), and for the different temperatures it was observed that its increase did not contribute significantly to the process efficiency (tested in the range of 20 to 60ºC). The integration of the two technologies presented the following percentages of global variation: chemical oxygem demand: -73.58%; turbidity: -97.65%; conductivity: -5.36%; dissolved oxygen: + 141.24%; total phenols: -81.77%; total iron: -69.97%; hydrogen peroxide: -97.78%; total solids: -46.37%; total fixed solids: -30.57%; total volatile solids: -46.65%; absorbance at 200 nm: -36.38%; absorbance at 400 nm: -77.37%. The pH, total iron and hydrogen peroxide parameters were controlled in the Fenton’s reagent process. / O efluente gerado pelas indústrias de cosméticos, proveniente de processos industriais, lavagens de tanques e descarte de lotes falhos, são altamente recalcitrantes devido à sua complexa composição química. A deposição de tais líquidos em corpos d’água deve seguir uma série de valores de parâmetros ambientais legislados para que não afetem de maneira negativa os meios receptores e seus ecossistemas. Por vezes, os métodos tradicionais de tratamento de efluentes não conseguem remover seu potencial poluidor de maneira satisfatória. Assim, a proposta deste trabalho foi integrar duas tecnologias de tratamento, reagente de Fenton e adsorção, a fim de alcançar máxima eficiência de remoção nos valores dos parâmetros de controle ambiental. O efluente real de uma indústria de cosméticos na região metropolitana de Goiânia foi utilizado como objeto de estudo. Os parâmetros ambientais analisados foram cor (por absorbância), ferro total, matéria orgânica (por demanda química de oxigênio), fenóis totais, pH, turbidez, condutividade, oxigênio dissolvido, H2O2 inicial e residual e sólidos totais, nos efluentes pré-tratado, pós-Fenton e final (pós-Fenton seguido de adsorção). O adsorvente foi caracterizado por análise elementar (CHN), termogravimetria (TG/DTA), adsorção e dessorção de N2 e espectroscopia de infravermelho. Para dar início ao tratamento via reagente de Fenton, foi realizado planejamento fatorial 23, para os fatores, concentração de Fe2+, concentração de H2O2 e valor de pH, a fim de delinear os parâmetros do processo. Destes dados, outros ensaios de Fenton foram realizados abrindo-se faixas de concentração de Fe2+, H2O2 e valor de pH, para avaliar a influência dos mesmos na remoção dos parâmetros ambientais supracitados. Os melhores resultados foram obtidos em concentração de Fe2+ 184,21 mg.L-1; concentração de H2O2 em 1300 mg L-1, e pH em 3,5. Em seguida, o efluente pós Fenton foi utilizado no processo de adsorção, em que foram testados sete tipos de carvões ativados nos ensaios. Para o carvão ativado que apresentou melhores resultados para os parâmetros ambientais supracitados, foram realizados testes cinéticos em batelada e com diferentes temperaturas. Na cinética, o tempo de equilíbrio foi atingido em 16 minutos (teste na faixa de 4min-24h), e para as diferentes temperaturas observou-se que o aumento da mesma não contribuiu significativamente na eficiência do processo (teste na faixa de 20 - 60ºC). A integração das duas tecnologias apresentou os seguintes percentuais de variação globais: demanda química de oxigênio: -73,58%; turbidez: -97,65%; condutividade: -5,36%; oxigênio dissolvido: +141,24%; fenóis totais: -81,77%; ferro total: -69,97%; peróxido de hidrogênio: -97,78%; sólidos totais: -46,37%; sólidos fixos totais: -30,57%; sólidos voláteis totais: -46,65%; absorbância em 200nm: -36,38%; sbsorbância em 400nm: -77,37%.

Page generated in 0.4945 seconds