• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 26
  • 1
  • Tagged with
  • 28
  • 28
  • 11
  • 10
  • 9
  • 7
  • 7
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Modelagem e análise de varistores de óxido metálico de zinco

Silveira, James January 2009 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica. / Made available in DSpace on 2012-10-24T15:22:01Z (GMT). No. of bitstreams: 0Bitstream added on 2013-07-16T20:27:30Z : No. of bitstreams: 1 266675.pdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / A proposta principal deste trabalho é apresentar um modelo para o varistor de óxido metálico de Zinco (ZnO) utilizado em pára-raios de alta tensão. Desenvolveu-se um modelo original por meio de um modelo matemático baseado na função de Langevin modificada. Quando comparada com curvas experimentais, a representação dos varistores por meio do modelo fornece resultados próximos à realidade. O modelo possui três parâmetros para serem encontrados. Desenvolveu-se uma metodologia de determinação dos valores dos parâmetros, a qual é realizada em um programa computacional. Os resultados obtidos por meio deste sistema comprovaram a capacidade de ajuste do modelo às curvas características relativas aos diferentes varistores e suas condições operacionais.Os três parâmetros do modelo proposto podem ser correlacionados com os fenômenos que regem os mecanismos de corrente de fuga, bem como permitem avaliar o processo de degradação do varistor ao longo da vida útil do pára-raios. Com base no modelo proposto e nos estudos desenvolvidos, uma nova metodologia é proposta para a avaliação dos varistores de ZnO. The main objective of this paper is to present a model for the zinc oxide (ZnO) varistor used in high voltage surge arresters. An original model was developed through a mathematical model based on the modified Langevin function. When compared to experimental curves, the modeled representation of the varistors provides results near reality. This model consists of three parameters to be determined. A methodology for determining the values for these parameters was developed, which is carried through in a computational program. The results obtained through this system corroborated the adjustment capacity of the model to the typical curves related to the different varistors and their operational conditions. The three parameters of the proposed model can be correlated with phenomena that conduct leakage current mechanisms. They also allow the evaluation of the process of varistor degradation during the whole working life of the arresters. Based on the proposed model and on carried out studies, a new methodology is proposed for the evaluation of the ZnO varistors.
2

Desenvolvimento de subsídios para aplicação em testes de avaliação de para-raios de ZnO

Videira, André Gomes 26 October 2012 (has links)
Dissertação (Mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2011 / Made available in DSpace on 2012-10-26T08:28:35Z (GMT). No. of bitstreams: 1 289520.pdf: 3449009 bytes, checksum: 05af5d1a72839db710e778daa5ceada8 (MD5) / Este trabalho apresenta como proposta principal verificar as influências externas, como a temperatura e harmônicos na rede sobre a corrente de fuga de para-raios para a avaliação de seu estado de operação, bem como a distribuição e o comportamento campos elétricos e magnéticos existentes em uma subestação no local da medição. Através de simulações, verificam-se possíveis influências sobre os valores medidos e os instrumentos de medição de corrente de fuga total, a corrente de fuga resistiva e a componente de terceira harmônica da corrente de fuga total, possibilitando maior segurança na avaliação do para-raios. Desenvolveu-se também um instrumento virtual para a obtenção da forma de onda da corrente resistiva, seu valor eficaz, de pico e suas harmônicas, baseado em uma metodologia para a separação das correntes resistiva e capacitiva a partir das formas de onda da corrente total e da tensão. Com base nos estudos e ensaios práticos realizados em subestação, se propôs uma metodologia para a padronização da realização de ensaios, visando uma maior confiabilidade na obtenção dos resultados da avaliação.
3

Analise comparativa de tecnicas de controle de sobretensões transitorias nas manobras de energização e religamento de linhas de transmissão / Comparative analysis of control switching transient techniques in transmission lines energization and reclosing maneuvers

Mestas Valero, Patricia 07 October 2007 (has links)
Orientador: Maria Cristina Dias Tavares / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-10T09:40:09Z (GMT). No. of bitstreams: 1 MestasValero_Patricia_M.pdf: 3064250 bytes, checksum: 898053aa51c68fc5e5e170f255fa1d05 (MD5) Previous issue date: 2007 / Resumo: As sobretensões em um sistema de transmissão não podem ser evitadas assim como a sua total supressão é extremamente difícil, entretanto, suas amplitudes podem ser reduzidas. Tradicionalmente, as sobretensões transitórias advindas das manobras de energização e religamento de linhas de transmissão são limitadas utilizando o ¿método convencional¿ como é o caso do uso de resistores de pré-inserção, este apesar de ser um método efetivo, apresenta uma aceitação de sua tecnologia tendente a diminuir devido ao alto custo de implementação e manutenção. Nos últimos tempos as principais empresas de transmissão do mundo têm se mostrado mais favoráveis a utilização de pára-raios e chaveamento controlado de disjuntores para o controle de sobretensões, mas na prática esta aplicação está apenas sendo iniciada. O presente trabalho foi realizado com o objetivo de analisar os diferentes métodos para o controle de sobretensões associadas às manobras de energização e religamento trifásico de linhas de transmissão em vazio determinando assim as melhores condições técnicas para a otimização destes processos. Apresentam-se os resultados obtidos através de simulações com o programa PSCAD/EMTDC de um caso específico com dados reais dos geradores, transformadores, características dos trechos de linhas de transmissão, pára-raios e reatores de compensação em derivação tendo como base um sistema de 500 kV / Abstract: The switching transient in transmission system cannot be prevented as well as its total suppression is extremely difficult, however, its magnitudes have to be limited. For long transmission lines, traditionally the switching transient overvoltages due to energization and reclosure are limited by the ¿conventional method¿ as is the case of preinsertion resistors in the line circuit breakers. Although this is an effective mitigation method it presents a decreasing acceptance due to the high cost of implementation and maintenance. Recently, important transmission firms in the world have shown the trend to the use of surge arresters and controlled switching breakers, in practical this application is only being initiated. The present work was realized with the objective of analyzing the different methods for the overvoltages control associates to energization and three-phase reclosing maneuvers of transmission lines to determine the best technique for the optimization of these processes. The results was obtained through digital simulations with PSCAD/EMTDC software for an specific case with real dates for generators, transformer, transmission lines, surge arresters and shunt compensation reactors of a 500 kV system / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
4

Avaliação do comportamento de para-raios poliméricos de distribuição sobclima simulado - envelhecimento acelerado - análise da hidrobobicidade / Assessment of the behavior of polymeric arrester distribution under simulated climate - Accelerated aging - analysis of hidrophobicity

Abreu, Sanderson Rocha de, 1969- 24 August 2018 (has links)
Orientador: José Pissolato Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-24T06:21:09Z (GMT). No. of bitstreams: 1 Abreu_SandersonRochade_M.pdf: 5297087 bytes, checksum: ef0820d93a3ed019ef6405a29a95a6c0 (MD5) Previous issue date: 2013 / Resumo: Os sistemas elétricos estão submetidos esporadicamente a várias formas de fenômenos transitórios, envolvendo variações súbitas de tensão e de corrente provocadas por descargas atmosféricas, faltas no sistema ou operação de disjuntores e chaves seccionadoras. Desta forma, os equipamentos elétricos além de estarem permanentemente solicitados pela tensão de operação dos sistemas, serão eventualmente submetidos por solicitações de tensões temporárias e transitórias, provenientes da ocorrência de distúrbios nos sistemas. A utilização de para-raios em sistemas de distribuição é uma prática que as empresas distribuidoras de energia elétrica vêm utilizando ao longo dos anos, para limitar as amplitudes das sobretensões transitórias de origem atmosférica nos sistemas de distribuição, reduzindo os efeitos dessas sobretensões sobre os equipamentos a níveis aceitáveis, de modo a aumentar a confiabilidade do sistema. Para isso, é imprescindível que os para-raios estejam operacionais ao longo de toda a sua vida útil e que resistam às diversas solicitações de tensões temporárias e transitórias sob diferentes condições ambientais. Este trabalho, pretende avaliar o comportamento dos diferentes projetos construtivos de para-raios de distribuição disponíveis no mercado nacional e internacional, mediante a avaliação sob condições de temperatura, umidade e precipitação pluviométrica, por meio de envelhecimento acelerado. Pretende fornecer subsídios que possam nortear escolhas importantes a serem tomadas pelas concessionárias de distribuição de energia elétrica do Grupo Energisa, como por exemplo, a seleção do equipamento adequado às condições climáticas de cada região atendida. A análise da hidrofobicidade dos polímeros utilizados na construção do para-raios tem um papel importante neste trabalho, pois poderá indicar a possível degradação do invólucro de acordo com as condições ambientais que este está exposto por região do Brasil, onde o Grupo Energisa tem atuação / Abstract: The eletrical systems are sporadically submitted to several forms of transient phenomena involving sudden changes in voltage and current caused by atmospheric surges, system faults or operating circuit breakers and switchgear. Thus, electrical equipment in addition to being permanently operating voltage required by the systems, are eventually submitted to requests for temporary and transient voltages, from the ocurrence of systems disturbances. The use of surge arresters in distribution systems is a practice that the electricity distribution companies have used over the years to limit the amplitudes of transient overvoltages of atmospheric origin in distribution systems and reducing the effects of these overvoltages on equipment at acceptable levels in order to increase system reliability. Therefore, it is necessry that surge arresters are operational throughout its life and resistant to several requests of temporary and transient voltages under different environmental conditions. This work intends to evaluate the behavior of different constructive projects of surge arresters distribution available on the national and international markets, through their evaluation under conditions of temperature, humidity and rainfall, through accelerated aging. Also intends to provide subsidies to orient important choices to be made by electricity distribution companies from Energisa Group, for example, the selection of appropriate climatic conditions equipment of each region served. For this, the analysis of the hydrophobicity of the polymers used in the construction of surge arresters, plays an important role in this work , as it may indicate the possible deterioration of the housing according to the environmental conditions that are exposed by the region of Brazil, where the Group Energisa has operations / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
5

"Avaliação da contaminação provocada por pará-raios radioativos de Amerício-241 descartados em lixões" / EVALUATION OF THE CONTAMINATION RISK BY 241AM FROM LIGHTNING RODS DISPOSED AT UNCONTROLLED GARBAGE DUMP

Marumo, Júlio Takehiro 20 September 2006 (has links)
Os pára-raios radioativos foram fabricados no Brasil até 1989, quando a Comissão Nacional de Energia Nuclear (CNEN) suspendeu a concessão de uso de material radioativo nesses artefatos. Desde então, o pára-raios radioativo tem sido substituído por outro, do tipo Franklin, e recolhido como rejeito radioativo. Entretanto, apenas 23 % do total fabricado no país foram entregues à CNEN. Esta situação é preocupante, pois a chance, desses artefatos serem descartados como resíduo comum e chegarem a lixões, é grande, uma vez que, segundo dados do Instituto Brasileiro de Geografia e Estatística (IBGE), em 2000, 63,6 % dos municípios brasileiros dispunham o resíduo nesses locais. Além disso, o amerício, o radionuclídeo mais empregado, é classificado como sendo um elemento de alta toxicidade, quando ingerido ou inalado. No presente trabalho, foram realizados experimentos de migração de Am-241 em lisímetros, com o objetivo de se avaliar o risco de contaminação provocada por pára-raios radioativos descartados como resíduo comum. Fontes radioativas removidas de pára-raios foram inseridas em lisímetros preenchidos com resíduo orgânico, coletado no restaurante do Instituto de Pesquisas Energéticas e Nucleares, IPEN-CNEN/SP, e chorume gerado foi periodicamente analisado para determinar suas características como pH, potencial redox, teor de sólidos e a concentração do material radioativo. O crescimento microbiano também foi avaliado, pelo método de contagem direta do número de unidades formadoras de colônia. A estimativa de risco foi baseada no cálculo de dose para membros do público, sendo a ingestão de água a via mais provável de exposição. O valor obtido foi cerca de 1000 vezes inferior ao limite de dose anual estabelecido, pela Comissão Internacional de Proteção Radiológica (ICRP), demonstrando que o risco de contaminação provocado pelo descarte de pára-raios em lixões é baixo. / Radioactive lightning rods were manufactured in Brazil until 1989, when the licenses for using radioactive sources in these products were lifted by the national nuclear authority. Since then, radioactive devices have been replaced by Franklin type one and collected as radioactive waste. However, only 23 percent of the estimated total number of installed rods was delivered to Brazilian Nuclear Commission (Comissão Nacional de Energia Nuclear – CNEN). This situation is of concern to us as there is a possibility of the rods being discarded as domestic waste, considering that in Brazil, 63.6 percent of the municipal solid waste is disposed at uncontrolled garbage dump, according to Instituto Brasileiro de Geografia e Estatística (IBGE) in 2000. In addition, americium, the most common employed radionuclide, is classified as a high toxicity element, when ingested or inhaled. In the present study, it was performed migration experiments of Am-241 by lysimeter system in order to evaluate the risk of contamination caused by radioactive lightning rods disposed as a common solid waste. Sources removed from lightning rods were placed inside lysimeters filled with organic waste, collected at the restaurant of Instituto de Pesquisas Energéticas e Nucleares, IPEN-CNEN/SP, and the generated leachate was periodically analyzed to determine its characteristics such as pH, redox potential, solid content and concentration of the radioactive material. Microbial growth was also evaluated by counting the number of colony forming units. The equivalent dose to members of the public has been calculated considering the ingestion of drinking water, the most probable mode of exposure. The final result was about 145 times below the effective dose limit of 1 mSv.year-1 for members of the public, established by the International Commission on Radiological Protection (ICRP), demonstrating that the risk caused by lightning rods disposed at uncontrolled garbage dump is low.
6

Análise de sistemas de transmissão HVDC baseados em conversores modulares multiníveis frente descargas atmosféricas. / Analysis of HVDC transmission systems based on multievel modular converters against lightnings.

Porfiro, Andrei Oliveira Mota 14 June 2018 (has links)
Atualmente, em virtude do aumento da demanda energética surgem diversas preocupações devido à escassez dos recursos energéticos tradicionais e os impactos ambientais proporcionados pelos mesmos. Neste contexto, para atender a demanda, diversos investimentos têm sido feitos no desenvolvimento de gerações alternativas e renováveis de energia, bem como na interconexão entre países para exportação de energia. Assim, os estudos exigem soluções mais eficazes para transmissão de energia elétrica, como os sistemas de transmissão High Voltage Direct Current (HVDC), uma alternativa aos sistemas de transmissão atuais, que são predominantemente em Corrente Alternada (CA). Dentre as principais vantagens dos sistemas HVDC, destaca-se a possibilidade de transmissão de grandes montantes de energia a longas distâncias com baixas perdas. Desta forma, eles estão susceptíveis às mais diversas condições meteorológicas e geográficas, em regiões isoladas, o que os tornam vulneráveis a descargas atmosféricas, afetando a segurança do sistema. Assim, neste trabalho, foi simulado um sistema HVDC, utilizando conversores Voltage Source Converter (VSC) do tipo modular multinível, do inglês Modular Multilevel Converter (MMC), frente descargas atmosféricas. Foram analisados diversos casos, visando verificar o comportamento dos conversores e validar a eficácia da utilização de para-raios de óxido metálico, comumente chamado de para-raios de óxido de zinco (ZnO), visto que este é um componente geralmente empregado em sistemas CA. O trabalho apresenta uma revisão acerca dos sistemas VSC-based HVDC (VSC-HVDC), tratando principalmente dos conversores MMC. Também foram descritos todos os modelos utilizados nas simulações, as quais foram realizadas através do software PSCAD/EMTDC. Concluiu-se que o correto dimensionamento e locação dos para-raios operam adequadamente em sistemas Corrente Contínua (CC). Um outro fato interresante é que a sobretensão gerada pelo surto atmosférico se propaga para o lado CA ao incidir no lado CC, mas o contrário não ocorre. / Nowadays, due to the increase in energy demand, several concerns arise due to the scarcity of traditional energy resources and the environmental impacts. In this context, to meet the demand, several investments have been made in the development of alternative and renewable generations of energy, as well as in the interconnection among countries for energy exports. Thus, studies require more effective solutions for electric power transmission, such as VSC-HVDC systems, an alternative to current transmission systems, which are predominantly in CA. Among the main advantages of VSC-HVDC systems, we can highlight the possibility of transmitting large amounts of energy over long distances with low losses. In this way, they are susceptible to the most diverse meteorological and geographic conditions, in isolated regions, which make them vulnerable to lightning, affecting the safety of the system. Thus, in this work, an HVDC system was simulated using VSC converters of the multilevel modular type (MMC) in front of lightnings. Several cases were analyzed in order to verify the behavior of the converters and validate the effectiveness of the use of metal oxide arresters, also known as ZnO arresters, since this is a commonly used component in CA systems. The work presents a review about the VSC-HVDC systems, mainly dealing with the MMC converters. We also described all the models used in the simulations, which were performed through the PSCAD/EMTDC software. It was concluded that the correct dimensioning and location of the arresters operate properly in CC systems. Another interresting fact is that the overvoltage generated by the lightning propagates to the AC side when it hits the CC side, but the reverse does not occur.
7

"Avaliação da contaminação provocada por pará-raios radioativos de Amerício-241 descartados em lixões" / EVALUATION OF THE CONTAMINATION RISK BY 241AM FROM LIGHTNING RODS DISPOSED AT UNCONTROLLED GARBAGE DUMP

Júlio Takehiro Marumo 20 September 2006 (has links)
Os pára-raios radioativos foram fabricados no Brasil até 1989, quando a Comissão Nacional de Energia Nuclear (CNEN) suspendeu a concessão de uso de material radioativo nesses artefatos. Desde então, o pára-raios radioativo tem sido substituído por outro, do tipo Franklin, e recolhido como rejeito radioativo. Entretanto, apenas 23 % do total fabricado no país foram entregues à CNEN. Esta situação é preocupante, pois a chance, desses artefatos serem descartados como resíduo comum e chegarem a lixões, é grande, uma vez que, segundo dados do Instituto Brasileiro de Geografia e Estatística (IBGE), em 2000, 63,6 % dos municípios brasileiros dispunham o resíduo nesses locais. Além disso, o amerício, o radionuclídeo mais empregado, é classificado como sendo um elemento de alta toxicidade, quando ingerido ou inalado. No presente trabalho, foram realizados experimentos de migração de Am-241 em lisímetros, com o objetivo de se avaliar o risco de contaminação provocada por pára-raios radioativos descartados como resíduo comum. Fontes radioativas removidas de pára-raios foram inseridas em lisímetros preenchidos com resíduo orgânico, coletado no restaurante do Instituto de Pesquisas Energéticas e Nucleares, IPEN-CNEN/SP, e chorume gerado foi periodicamente analisado para determinar suas características como pH, potencial redox, teor de sólidos e a concentração do material radioativo. O crescimento microbiano também foi avaliado, pelo método de contagem direta do número de unidades formadoras de colônia. A estimativa de risco foi baseada no cálculo de dose para membros do público, sendo a ingestão de água a via mais provável de exposição. O valor obtido foi cerca de 1000 vezes inferior ao limite de dose anual estabelecido, pela Comissão Internacional de Proteção Radiológica (ICRP), demonstrando que o risco de contaminação provocado pelo descarte de pára-raios em lixões é baixo. / Radioactive lightning rods were manufactured in Brazil until 1989, when the licenses for using radioactive sources in these products were lifted by the national nuclear authority. Since then, radioactive devices have been replaced by Franklin type one and collected as radioactive waste. However, only 23 percent of the estimated total number of installed rods was delivered to Brazilian Nuclear Commission (Comissão Nacional de Energia Nuclear – CNEN). This situation is of concern to us as there is a possibility of the rods being discarded as domestic waste, considering that in Brazil, 63.6 percent of the municipal solid waste is disposed at uncontrolled garbage dump, according to Instituto Brasileiro de Geografia e Estatística (IBGE) in 2000. In addition, americium, the most common employed radionuclide, is classified as a high toxicity element, when ingested or inhaled. In the present study, it was performed migration experiments of Am-241 by lysimeter system in order to evaluate the risk of contamination caused by radioactive lightning rods disposed as a common solid waste. Sources removed from lightning rods were placed inside lysimeters filled with organic waste, collected at the restaurant of Instituto de Pesquisas Energéticas e Nucleares, IPEN-CNEN/SP, and the generated leachate was periodically analyzed to determine its characteristics such as pH, redox potential, solid content and concentration of the radioactive material. Microbial growth was also evaluated by counting the number of colony forming units. The equivalent dose to members of the public has been calculated considering the ingestion of drinking water, the most probable mode of exposure. The final result was about 145 times below the effective dose limit of 1 mSv.year-1 for members of the public, established by the International Commission on Radiological Protection (ICRP), demonstrating that the risk caused by lightning rods disposed at uncontrolled garbage dump is low.
8

Análise de sistemas de transmissão HVDC baseados em conversores modulares multiníveis frente descargas atmosféricas. / Analysis of HVDC transmission systems based on multievel modular converters against lightnings.

Andrei Oliveira Mota Porfiro 14 June 2018 (has links)
Atualmente, em virtude do aumento da demanda energética surgem diversas preocupações devido à escassez dos recursos energéticos tradicionais e os impactos ambientais proporcionados pelos mesmos. Neste contexto, para atender a demanda, diversos investimentos têm sido feitos no desenvolvimento de gerações alternativas e renováveis de energia, bem como na interconexão entre países para exportação de energia. Assim, os estudos exigem soluções mais eficazes para transmissão de energia elétrica, como os sistemas de transmissão High Voltage Direct Current (HVDC), uma alternativa aos sistemas de transmissão atuais, que são predominantemente em Corrente Alternada (CA). Dentre as principais vantagens dos sistemas HVDC, destaca-se a possibilidade de transmissão de grandes montantes de energia a longas distâncias com baixas perdas. Desta forma, eles estão susceptíveis às mais diversas condições meteorológicas e geográficas, em regiões isoladas, o que os tornam vulneráveis a descargas atmosféricas, afetando a segurança do sistema. Assim, neste trabalho, foi simulado um sistema HVDC, utilizando conversores Voltage Source Converter (VSC) do tipo modular multinível, do inglês Modular Multilevel Converter (MMC), frente descargas atmosféricas. Foram analisados diversos casos, visando verificar o comportamento dos conversores e validar a eficácia da utilização de para-raios de óxido metálico, comumente chamado de para-raios de óxido de zinco (ZnO), visto que este é um componente geralmente empregado em sistemas CA. O trabalho apresenta uma revisão acerca dos sistemas VSC-based HVDC (VSC-HVDC), tratando principalmente dos conversores MMC. Também foram descritos todos os modelos utilizados nas simulações, as quais foram realizadas através do software PSCAD/EMTDC. Concluiu-se que o correto dimensionamento e locação dos para-raios operam adequadamente em sistemas Corrente Contínua (CC). Um outro fato interresante é que a sobretensão gerada pelo surto atmosférico se propaga para o lado CA ao incidir no lado CC, mas o contrário não ocorre. / Nowadays, due to the increase in energy demand, several concerns arise due to the scarcity of traditional energy resources and the environmental impacts. In this context, to meet the demand, several investments have been made in the development of alternative and renewable generations of energy, as well as in the interconnection among countries for energy exports. Thus, studies require more effective solutions for electric power transmission, such as VSC-HVDC systems, an alternative to current transmission systems, which are predominantly in CA. Among the main advantages of VSC-HVDC systems, we can highlight the possibility of transmitting large amounts of energy over long distances with low losses. In this way, they are susceptible to the most diverse meteorological and geographic conditions, in isolated regions, which make them vulnerable to lightning, affecting the safety of the system. Thus, in this work, an HVDC system was simulated using VSC converters of the multilevel modular type (MMC) in front of lightnings. Several cases were analyzed in order to verify the behavior of the converters and validate the effectiveness of the use of metal oxide arresters, also known as ZnO arresters, since this is a commonly used component in CA systems. The work presents a review about the VSC-HVDC systems, mainly dealing with the MMC converters. We also described all the models used in the simulations, which were performed through the PSCAD/EMTDC software. It was concluded that the correct dimensioning and location of the arresters operate properly in CC systems. Another interresting fact is that the overvoltage generated by the lightning propagates to the AC side when it hits the CC side, but the reverse does not occur.
9

Metodologia da manutenção centrada em confiabilidade aplicada a pára-raios de alta tensão

Britto, Tales Marques de January 2006 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica / Made available in DSpace on 2012-10-22T18:17:34Z (GMT). No. of bitstreams: 1 231354.pdf: 2100774 bytes, checksum: dd0e4036814f16c90d7a42ec7ec10f00 (MD5) / Este trabalho de dissertação apresenta a aplicação da metodologia da Manutenção Centrada em Confiabilidade (MCC) em pára-raios de alta tensão, como forma de apoio à tomada de decisão em um sistema de Análise e Diagnóstico de Equipamentos de Subestações de Transmissão de Energia (DianE). Este trabalho aborda o equipamento pára-raios descrevendo suas características construtivas e funcionais e expondo os fatores que contribuem para o surgimento de falhas, assim como a descrição de suas causas e conseqüências. Apresenta também a MCC, sua origem, definições e objetivos, além da sua aplicação em pára-raios de alta tensão. O conhecimento necessário para a implementação desta ferramenta foi obtido a partir de pesquisas realizadas em um banco de dados históricos de equipamentos de uma empresa de transmissão de energia elétrica e de entrevistas com especialistas da manutenção neste tipo de equipamento. Como objetivo principal, busca-se o diagnóstico mais rápido e eficiente de falhas potenciais antes que elas aconteçam, propiciando aumento da qualidade, disponibilidade, confiabilidade e segurança do sistema, além da diminuição dos custos de manutenção. This dissertation describes de application of the Reliability Centered Maintenance (RCM) technique to high voltage surge arresters, aiming to support the decision making task within a system for Analysis and Diagnosis of Substations of Energy Transmission (DianE). This document firstly describes some constructive and functional aspects of surge arresters and highlights factors that contribute to their failures, as well as the description of its causes and consequences. The origin, main definitions and objectives of the Reliability Centered Maintenance are also presented, besides its application to high voltage surge arresters. The knowledge necessary to implement this tool was obtained from studies of a historical database of the equipment belonging to a transmission company and from interviews with maintenance personnel specialized in surge arresters. The main objective of the support tool implemented is to provide a faster and more efficient detection of potential failures before they occur, allowing for an increase in power system quality, reliability and security, besides a reduction in maintenance costs.
10

Avaliação do desempenho dos equipamentos mamográficos e da qualidade das imagens em Serviços de Saúde do Município de São Paulo / Equipment performance, image quality and dose: survey of mamographic facilities in São Paulo, Brazil

Ruberti Filha, Eny Moreira [UNIFESP] 27 July 2011 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:49:34Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-07-27 / Objetivo: Qualificar o processo gerador da imagem mamográfica, segundo critérios normativos nacionais e europeus, identificando os testes de controle de qualidade relevantes e propondo um conjuntos de testes que possam ser realizados por técnicos e físicos nos serviços mamográficos. Métodos: Em uma primeira etapa foram efetuados testes de verificação do desempenho da qualidade de cinco mamógrafos da rede pública. A detecção de sinais foi verificada utilizando imagens do simulador estatístico Alvim e a concordância do especialista foi medida pelo valor de kappa. Na segunda etapa foram realizados durante cinco semanas consecutivas testes relacionados ao processamento dos filmes, verificação da constância da densidade óptica de referência e desempenho do AEC. Foi analisada a qualidade das imagens do simulador CIRS e efetuada a medida da dose na entrada da pele(DEP) com dosímetros TLD. Na terceira etapa, os testes descritos na etapa inicial foram realizados em 13 mamógrafos. Com o intuito de reduzir a subjetividade do processo de análise, as imagens do simulador CIRS foram digitalizadas e avaliadas por meio dos parâmetros contraste e ruído. A dose glandular média foi determinada. Na quarta etapa foram realizados os testes de verificação de qualidade em dois mamógrafos digitais (DR) da rede privada e em dois mamógrafos analógicos com radiografia computadorizada (CR) instalados na rede pública de saúde. Foram efetuados testes de desempenho e qualidade da imagem propostos no protocolo europeu. Resultados: O desempenho dos equipamentos apresentou resultados satisfatórios, à exceção da camada semirredutora, AEC e processamento de filmes. As imagens do simulador Alvim foram analisadas numa central de laudos e os resultados da detecção de fibras e microcalcificações foram insatisfatórios, à exceção de uma única instalação. Na primeira leitura, os valores de kappa variaram de 0,02-0,68, sendo kappa para microcalcificações de 0,26-0,6 e kappa para fibras de 0,06-0,76. Na segunda leitura, os valores de kappa foram estatisticamente superiores. A dose glandular media foi 1,95mGy(0,65-3,5) e densidade óptica de referência 1,54-1,85. Os resultados das cinco semanas dos testes relacionados ao processamento dos filmes, à constância da densidade óptica de referência e desempenho do AEC foram insatisfatórios. O valor médio da DEP foi 9,33mGy(6,54- 17,26), as temperaturas do revelador e fixador variaram de 30,8-470C e de 21-640C, respectivamente. A densidade óptica de referência foi em média 1,84(1,05-2,46). Na terceira etapa, a dose glandular média calculada para a mama de 4,5cm variou de 1,0- 1,8mGy e de 2,43-4,95mGy para espessura de 6,5cm. Os valores de kappa variaram de 0,34-0,63, sendo kappa para microcalcificações de 0,32-0,71 e kappa para fibras de 0,40-0,68. Nesta fase a análise da densidade óptica de referência apresentou valores inferiores a 1,4 sugerindo o subprocessamento das imagens. A relação sinal-ruído variou de 5,9-24, 6% e de 6,0-24, 6% para mamas com espessura de 4,5 e 6,5cm, respectivamente. Conclusão: A metodologia possibilitou verificar a importância de controlar as etapas do processo desde a geração até a análise da imagem pelo especialista. Este controle deve ser efetuado com frequência superior à requerida pelas normas. Torna-se necessário introduzir o cálculo da dose glandular média no programa de garantia da qualidade em âmbito nacional. A análise das imagens efetuadas na central de laudos mostrou a necessidade da padronização na linguagem do diagnóstico, bem como o controle do ambiente. O aumento da frequência dos testes evidenciou que o processamento do filme é inadequado, recorrente e contribui efetivamente para a redução da qualidade das imagens. / Objective: Verify equipment performance and image quality according to National and European test protocols. Identify the essential quality control test set that can be performed in the mammography services in order to guarantee quality in the imaging acquisition and reading process. Methods: Firstly, were evaluated the performance tests of five mammographic equipment of the public facilities. The signal detection was verified by Alvim statistic phantom and kappa value was measured in consonance with the specialist. Secondly, five weeks of consecutive tests were performed relating the film processing, the reference optical density (OD) constancy and the AEC performance. The CIRS phantom quality images were analyzed and the entrance surface air kerma (ESAK) was performed with TLD dosimeters. Thirdly, tests were replicated in thirteen mammography units. At this step, CIRS phantom images were digitalized and contrast and noise parameters were evaluated. The average glandular dose (MGD) was also calculated. Fourthly, the quality check tests were performed in two digital mammography equipment (DR) of private facilities and two conventional mammography equipment units connected with computerized radiography system(CR) installed in the public health facilities. Results: The equipment performance presented satisfactory results, except for the HVL, AEC and film processing. The Alvim phantom images were analyzed in a teleradiology facility by specialists and the results of the fiber and microcalcification detection were unacceptable, except for a single one. On the first reading, the kappa values varied from 0.02 to 0.68, being kappa for the microcalcifications from 0.26 to 0.6 and kappa for fibers from 0.06 to 0.76. On the second one, the kappa values were statistically superior. The mean glandular dose was 1.95mGy (0.65-3.5) and the OD measurements varied from 1.54 to 1.85. The five weeks tests results related to the film processing, OD constancy and AEC performance were unacceptable. The mean ESAK result was 9.33mGy (6.54-17.26), OD was 1.84(1.05-2.46), developer and fixer temperatures varied from 30.8 to 470C and 21 to 640C, respectively. On the third step, the MGD calculated for 4.5cm breast thickness varied from 1.0 to1.8mGy and 2.43 to 4.95mGy for 6.5cm breast thickness. The kappa values varied from 0.34 to 0.63, being kappa for microcalcification from 0.32 to 0.71 and kappa for fibers from 0.40 to 0.68. In this period, the OD analysis presented values below 1.4 that suggested a subprocessing image. The SNR varied from 5.9 to 24, 6% and 6.0 to 24, 6% for 4.5 and 6.5cm breast thicknesses, respectively. Conclusion: The methodology allowed verifying the importance of controlling process since the generation until the image analysis by the specialist. This control must be performed more often than required by the Brazilian law. It has become necessary to introduce the MGD calculation in the quality assurance program nationwide. The image analysis performed at the teleradiology facilities showed the need of diagnosis language standardization, as well as the viewing conditions. Clearly, the tests frequency showed that inadequate film processing is a recurring item and also contributes effectively for the quality image reduction. / TEDE / BV UNIFESP: Teses e dissertações

Page generated in 0.0473 seconds