Avaliação do desempenho dos equipamentos mamográficos e da qualidade das imagens em Serviços de Saúde do Município de São Paulo / Equipment performance, image quality and dose: survey of mamographic facilities in São Paulo, BrazilRuberti Filha, Eny Moreira [UNIFESP] 27 July 2011 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:49:34Z (GMT). No. of bitstreams: 0
Previous issue date: 2011-07-27 / Objetivo: Qualificar o processo gerador da imagem mamográfica, segundo critérios normativos nacionais e europeus, identificando os testes de controle de qualidade relevantes e propondo um conjuntos de testes que possam ser realizados por técnicos e físicos nos serviços mamográficos. Métodos: Em uma primeira etapa foram efetuados testes de verificação do desempenho da qualidade de cinco mamógrafos da rede pública. A detecção de sinais foi verificada utilizando imagens do simulador estatístico Alvim e a concordância do especialista foi medida pelo valor de kappa. Na segunda etapa foram realizados durante cinco semanas consecutivas testes relacionados ao processamento dos filmes, verificação da constância da densidade óptica de referência e desempenho do AEC. Foi analisada a qualidade das imagens do simulador CIRS e efetuada a medida da dose na entrada da pele(DEP) com dosímetros TLD. Na terceira etapa, os testes descritos na etapa inicial foram realizados em 13 mamógrafos. Com o intuito de reduzir a subjetividade do processo de análise, as imagens do simulador CIRS foram digitalizadas e avaliadas por meio dos parâmetros contraste e ruído. A dose glandular média foi determinada. Na quarta etapa foram realizados os testes de verificação de qualidade em dois mamógrafos digitais (DR) da rede privada e em dois mamógrafos analógicos com radiografia computadorizada (CR) instalados na rede pública de saúde. Foram efetuados testes de desempenho e qualidade da imagem propostos no protocolo europeu. Resultados: O desempenho dos equipamentos apresentou resultados satisfatórios, à exceção da camada semirredutora, AEC e processamento de filmes. As imagens do simulador Alvim foram analisadas numa central de laudos e os resultados da detecção de fibras e microcalcificações foram insatisfatórios, à exceção de uma única instalação. Na primeira leitura, os valores de kappa variaram de 0,02-0,68, sendo kappa para microcalcificações de 0,26-0,6 e kappa para fibras de 0,06-0,76. Na segunda leitura, os valores de kappa foram estatisticamente superiores. A dose glandular media foi 1,95mGy(0,65-3,5) e densidade óptica de referência 1,54-1,85. Os resultados das cinco semanas dos testes relacionados ao processamento dos filmes, à constância da densidade óptica de referência e desempenho do AEC foram insatisfatórios. O valor médio da DEP foi 9,33mGy(6,54- 17,26), as temperaturas do revelador e fixador variaram de 30,8-470C e de 21-640C, respectivamente. A densidade óptica de referência foi em média 1,84(1,05-2,46). Na terceira etapa, a dose glandular média calculada para a mama de 4,5cm variou de 1,0- 1,8mGy e de 2,43-4,95mGy para espessura de 6,5cm. Os valores de kappa variaram de 0,34-0,63, sendo kappa para microcalcificações de 0,32-0,71 e kappa para fibras de 0,40-0,68. Nesta fase a análise da densidade óptica de referência apresentou valores inferiores a 1,4 sugerindo o subprocessamento das imagens. A relação sinal-ruído variou de 5,9-24, 6% e de 6,0-24, 6% para mamas com espessura de 4,5 e 6,5cm, respectivamente. Conclusão: A metodologia possibilitou verificar a importância de controlar as etapas do processo desde a geração até a análise da imagem pelo especialista. Este controle deve ser efetuado com frequência superior à requerida pelas normas. Torna-se necessário introduzir o cálculo da dose glandular média no programa de garantia da qualidade em âmbito nacional. A análise das imagens efetuadas na central de laudos mostrou a necessidade da padronização na linguagem do diagnóstico, bem como o controle do ambiente. O aumento da frequência dos testes evidenciou que o processamento do filme é inadequado, recorrente e contribui efetivamente para a redução da qualidade das imagens. / Objective: Verify equipment performance and image quality according to National and European test protocols. Identify the essential quality control test set that can be performed in the mammography services in order to guarantee quality in the imaging acquisition and reading process. Methods: Firstly, were evaluated the performance tests of five mammographic equipment of the public facilities. The signal detection was verified by Alvim statistic phantom and kappa value was measured in consonance with the specialist. Secondly, five weeks of consecutive tests were performed relating the film processing, the reference optical density (OD) constancy and the AEC performance. The CIRS phantom quality images were analyzed and the entrance surface air kerma (ESAK) was performed with TLD dosimeters. Thirdly, tests were replicated in thirteen mammography units. At this step, CIRS phantom images were digitalized and contrast and noise parameters were evaluated. The average glandular dose (MGD) was also calculated. Fourthly, the quality check tests were performed in two digital mammography equipment (DR) of private facilities and two conventional mammography equipment units connected with computerized radiography system(CR) installed in the public health facilities. Results: The equipment performance presented satisfactory results, except for the HVL, AEC and film processing. The Alvim phantom images were analyzed in a teleradiology facility by specialists and the results of the fiber and microcalcification detection were unacceptable, except for a single one. On the first reading, the kappa values varied from 0.02 to 0.68, being kappa for the microcalcifications from 0.26 to 0.6 and kappa for fibers from 0.06 to 0.76. On the second one, the kappa values were statistically superior. The mean glandular dose was 1.95mGy (0.65-3.5) and the OD measurements varied from 1.54 to 1.85. The five weeks tests results related to the film processing, OD constancy and AEC performance were unacceptable. The mean ESAK result was 9.33mGy (6.54-17.26), OD was 1.84(1.05-2.46), developer and fixer temperatures varied from 30.8 to 470C and 21 to 640C, respectively. On the third step, the MGD calculated for 4.5cm breast thickness varied from 1.0 to1.8mGy and 2.43 to 4.95mGy for 6.5cm breast thickness. The kappa values varied from 0.34 to 0.63, being kappa for microcalcification from 0.32 to 0.71 and kappa for fibers from 0.40 to 0.68. In this period, the OD analysis presented values below 1.4 that suggested a subprocessing image. The SNR varied from 5.9 to 24, 6% and 6.0 to 24, 6% for 4.5 and 6.5cm breast thicknesses, respectively. Conclusion: The methodology allowed verifying the importance of controlling process since the generation until the image analysis by the specialist. This control must be performed more often than required by the Brazilian law. It has become necessary to introduce the MGD calculation in the quality assurance program nationwide. The image analysis performed at the teleradiology facilities showed the need of diagnosis language standardization, as well as the viewing conditions. Clearly, the tests frequency showed that inadequate film processing is a recurring item and also contributes effectively for the quality image reduction. / TEDE / BV UNIFESP: Teses e dissertações
|
2 |
Desenvolvimento de phantoms para tomografia com feixe de prótonsMilhoretto, Edney 13 April 2012 (has links)
CNPq / Neste trabalho foram desenvolvidos phantoms para dois protótipos de tomografia com feixe de prótons (pCT). Um phantom foi desenvolvido para um protótipo de um mini tomógrafo utilizando um feixe de prótons de baixa energia, que está sendo desenvolvido na Universidade Tecnológica Federal do Paraná (UTFPR). O protótipo encontra-se em fase de teste no cíclotron CV-28 do Instituto de Engenharia Nuclear (IEN). Dois outros phantoms foram desenvolvidos para um protótipo de pCT no Centro Médico da Universidade de Loma Linda – CA, EUA (LLUMC). Os código GEANT4 e SRIM foram utilizados para simular todos os elementos que compõe os protótipos. Também foram feitos aprimoramentos no protótipo da UTFPR/IEN, entre eles um sistema de controle eletrônico do mecanismo, operado por um programa através de um computador, alteração no sistema de colimação para melhorar a resolução e a reconstrução de imagens obtidas por simulações. Foram realizados testes experimentais de perda de energia de prótons em polietileno de alta densidade (PEAD) no CV-28. Também foi feito experimentos de perda de energia de prótons em camadas de Poliestireno no LLUMC e comparação com dados simulados. Esses dois phantoms em PEAD foram construídos e testados no protótipo do LLUMC e um programa foi desenvolvido para a análise dos dados. / In this work phantoms were developed for two tomographic systems with proton beam (pCT). A phantom was developed for a mini scanner using a low energy proton beam, which is being developed at the Federal University of Technology - Parana (UTFPR) and tested at the CV-28 cyclotron at the Institute of Nuclear Engineering (IEN). Two additional phantoms were developed for the pCT prototype at Loma Linda University Medical Center – CA, USA (LLUMC). SRIM and Geant4 codes were used to simulate all the elements of the prototypes. Improvements were made in the UTFPR/IEN prototype such as electronic control system of mechanism, controlled by a computer program, upgrade in the collimation system to improve the resolution of reconstructed images obtained by simulations. Experimental energy loss tests were done with polyethylene protons of high density (PEAD) in CV-28. Experiments of energy loss in layers of polystyrene at the LLUMC were also done and compared with simulated data. Both phantoms were constructed and tested in the prototype of LLUMC and a program was developed for data analysis.
|
3 |
Avaliação de protocolo para redução da distorção em estereotaxia para ressonância magnética de três tesla / A method for geometric distortion correction for stereotaxic neurosurgery on three teslaWagner Malagó Tavares 07 December 2015 (has links)
Introdução: o presente estudo demonstra a aplicação de um algoritmo para correção de distorções em imagens de RM em 3T. Métodos: foi utilizado um Modelo Tridimensional com Alvos (MTA) de acrílico (Micromar, São Paulo, Brasil) montado em uma plataforma com as dimensões e características de um arco estereotáctico. O MTA foi submetido à aquisição de imagens em uma bobina de crânio utilizando o aparelho Philips 3T Magnetom Sigma LX(TM) (Philips Medical Systems, Eindhoven, Netherlands). Para cada aquisição duas imagens foram obtidas, a normal e a reversa (nRM e rRM, respectivamente). Foi aplicado o protocolo de correção com gradiente reverso para produzir coordenadas x, y e z corrigidas. Após ter sido determinada a acurácia dos alvos, foram submetidos 20 pacientes ao mesmo protocolo para determinar a validade em indivíduos. Resultados: a análise dos dados demonstrou que as diferenças entre observadores não foram estatisticamente significantes. Além disso, os pontos obtidos após o processo de retificação das coordenadas no MTA revelou uma distorção média de 1,05 mm. Nos pacientes, a distorção pré correção variava de 0 a 5,6 mm; após a correção variou entre 0 e 3,5 mm. Conclusão: o presente estudo examinou uma técnica de retificação das distorções geométricas encontradas em imagens de RM. Esta mostrou-se bem sucedida em produzir resultados consistentemente acurados para registro de alvos estereotácticos. A técnica pode ser aplicada de maneira universal a todas as imagens de RM adquiridas em protocolo spin-echo e corrige as distorções geométricas presentes / The present work presents an application of a image distortion correction algorithm for 3T MR images. Methods: We used a phantom head model (Micromar, São Paulo, Brazil) mounted on a plataform with the dimensions and features of a stereotactic frame. The phantom was scanned within the head coil of a Philips 3T Magnetom Sigma LX(TM) (Philips Medical Systems, Eindhoven, Netherlands). For each scan, 2 images were obtained - the normal and the reversed image (nMR and rMR, respectively). We applied the inverted gradient correction protocol to produce a corrected x, y and z coordinate. After we ensure target accuracy we submitted 20 patients to the same protocol to exactitude evaluation in human subjects. Results: For all the analyzed data, the differences among the observers were not statistically significant. Moreover, the data rectification proved to be effective as the average distortion on phantom, after correction, was 1.05 mm. On patients the pre-correction distortion varied between 0 and 5.6mm, after correction it varied between 0 mm and 3.5 mm. Conclusion: This study examined a rectifying technique for correcting geometric distortions encountered in the MR images, and the technique proved to be highly successful in producing consistently accurate stereotactic target registration. The technique is universally applicable to all routinely employed spin-echo MR images, and corrects for geometric distortions
|
4 |
Avaliação de protocolo para redução da distorção em estereotaxia para ressonância magnética de três tesla / A method for geometric distortion correction for stereotaxic neurosurgery on three teslaTavares, Wagner Malagó 07 December 2015 (has links)
Introdução: o presente estudo demonstra a aplicação de um algoritmo para correção de distorções em imagens de RM em 3T. Métodos: foi utilizado um Modelo Tridimensional com Alvos (MTA) de acrílico (Micromar, São Paulo, Brasil) montado em uma plataforma com as dimensões e características de um arco estereotáctico. O MTA foi submetido à aquisição de imagens em uma bobina de crânio utilizando o aparelho Philips 3T Magnetom Sigma LX(TM) (Philips Medical Systems, Eindhoven, Netherlands). Para cada aquisição duas imagens foram obtidas, a normal e a reversa (nRM e rRM, respectivamente). Foi aplicado o protocolo de correção com gradiente reverso para produzir coordenadas x, y e z corrigidas. Após ter sido determinada a acurácia dos alvos, foram submetidos 20 pacientes ao mesmo protocolo para determinar a validade em indivíduos. Resultados: a análise dos dados demonstrou que as diferenças entre observadores não foram estatisticamente significantes. Além disso, os pontos obtidos após o processo de retificação das coordenadas no MTA revelou uma distorção média de 1,05 mm. Nos pacientes, a distorção pré correção variava de 0 a 5,6 mm; após a correção variou entre 0 e 3,5 mm. Conclusão: o presente estudo examinou uma técnica de retificação das distorções geométricas encontradas em imagens de RM. Esta mostrou-se bem sucedida em produzir resultados consistentemente acurados para registro de alvos estereotácticos. A técnica pode ser aplicada de maneira universal a todas as imagens de RM adquiridas em protocolo spin-echo e corrige as distorções geométricas presentes / The present work presents an application of a image distortion correction algorithm for 3T MR images. Methods: We used a phantom head model (Micromar, São Paulo, Brazil) mounted on a plataform with the dimensions and features of a stereotactic frame. The phantom was scanned within the head coil of a Philips 3T Magnetom Sigma LX(TM) (Philips Medical Systems, Eindhoven, Netherlands). For each scan, 2 images were obtained - the normal and the reversed image (nMR and rMR, respectively). We applied the inverted gradient correction protocol to produce a corrected x, y and z coordinate. After we ensure target accuracy we submitted 20 patients to the same protocol to exactitude evaluation in human subjects. Results: For all the analyzed data, the differences among the observers were not statistically significant. Moreover, the data rectification proved to be effective as the average distortion on phantom, after correction, was 1.05 mm. On patients the pre-correction distortion varied between 0 and 5.6mm, after correction it varied between 0 mm and 3.5 mm. Conclusion: This study examined a rectifying technique for correcting geometric distortions encountered in the MR images, and the technique proved to be highly successful in producing consistently accurate stereotactic target registration. The technique is universally applicable to all routinely employed spin-echo MR images, and corrects for geometric distortions
|
5 |
Estimulador galvânico vestibular para fMRIManczak, Tiago 30 July 2012 (has links)
Este trabalho apresenta o desenvolvimento de um estimulador galvânico vestibular para ser usado em experimentos de imageamento por ressonância magnética funcional (fMRI). Em experiências de fMRI é necessário a produção de estímulos somatossensoriais no paciente. Os estímulos devem ser sincronizados com a sequência de pulsos da fMRI. O estimulador foi dividido em circuitos analógicos (colocados dentro da sala do magneto) e circuitos digitais (sala de comando do sistema de MRI). A comunicação entre os circuitos é feita através de fibra óptica. Experimentos de fMRI realizados com voluntários demonstraram que o estimulador proposto é capaz de manter a sincronização com sistema de fMRI e pode ser usado para localizar as áreas do cérebro que são ativados pelo sistema vestibular. / This work presents the development of a galvanic vestibular stimulator to be used in functional magnetic resonance imaging experiments (fMRI). In fMRI experiments it is required the production of somatosensory stimuli in the patient must be sincronized with the fMRI pulse sequence. The stimulator circuits were divided in analog circuits (placed within the magnet room) and digital circuits (placed in the MRI command room). The communication between the circuits is made through optical fiber. fMRI experiments performed with volunteers demonstrated that the proposed stimulator is able to keep the sincronization with the MRI system and can be used to locate the brain areas that are activated by the vestibular system.
|
6 |
Adaptação do código Geant4 para conversão de imagens DICOM em phantom virtualSilva, Fabrício Loreni da 01 April 2013 (has links)
CAPES / Este trabalho apresenta a adaptação do código Geant4 para conversão de imagens DICOM (Digital Imaging and Communications in Medicine) de crânio, obtidas em tomografia convencional (CT), em um phantom antropomórfico virtual. O trabalho foi baseado no exemplo médico denominado “Código Dicom”, disponibilizado pelos desenvolvedores do código Geant4. Durante a execução do trabalho foram feitas reestruturações no exemplo “Código Dicom” para a conversão direta de imagens tomográficas em um phantom virtual. Foram retirados do código todos os passos referentes aos eventos físicos nucleares. Foi reformulado o arquivo DicomHandler.cc para não realizar a compressão dos pixels da imagem de CT. Em seguida foi realizada a conversão direta de imagens tomográficas, de um phantom físico de polietileno (PEAD) com núcleo central de acrílico e de um crânio real humano, em phantoms virtuais para o código Geant4. Os resultados demonstraram que com este código é possível a reconstrução de áreas anatômicas com geometrias complexas, partindo do uso de imagens tomográficas reais. / This work presents the adaptation of the Geant4 code for converting DICOM (Digital Imaging and Communications in Medicine) images of a skull, obtained in conventional tomography (CT), into a virtual anthropomorphic phantom. The work was based on the medical example named "Dicom Code" provided by the developers of the code Geant4. During the execution, restructurings using the "Dicom Code" example were made to achieve the direct conversion of tomographic images into a virtual phantom. All the steps referring to nuclear physical events were removed. The file DicomHandler.cc was reformulated in order to avoid the pixels compression of the CT image. The CT images of a physical polyethylene (PEAD) phantom with acrylic core and a real human skull were then converted into virtual phantoms for the code Geant4. The results showed that with this code, it may be possible the reconstruction of anatomical areas with complex geometries, based on the use of real tomographic images.
|
7 |
Estimulador galvânico vestibular para fMRIManczak, Tiago 30 July 2012 (has links)
Este trabalho apresenta o desenvolvimento de um estimulador galvânico vestibular para ser usado em experimentos de imageamento por ressonância magnética funcional (fMRI). Em experiências de fMRI é necessário a produção de estímulos somatossensoriais no paciente. Os estímulos devem ser sincronizados com a sequência de pulsos da fMRI. O estimulador foi dividido em circuitos analógicos (colocados dentro da sala do magneto) e circuitos digitais (sala de comando do sistema de MRI). A comunicação entre os circuitos é feita através de fibra óptica. Experimentos de fMRI realizados com voluntários demonstraram que o estimulador proposto é capaz de manter a sincronização com sistema de fMRI e pode ser usado para localizar as áreas do cérebro que são ativados pelo sistema vestibular. / This work presents the development of a galvanic vestibular stimulator to be used in functional magnetic resonance imaging experiments (fMRI). In fMRI experiments it is required the production of somatosensory stimuli in the patient must be sincronized with the fMRI pulse sequence. The stimulator circuits were divided in analog circuits (placed within the magnet room) and digital circuits (placed in the MRI command room). The communication between the circuits is made through optical fiber. fMRI experiments performed with volunteers demonstrated that the proposed stimulator is able to keep the sincronization with the MRI system and can be used to locate the brain areas that are activated by the vestibular system.
|
8 |
Adaptação do código Geant4 para conversão de imagens DICOM em phantom virtualSilva, Fabrício Loreni da 01 April 2013 (has links)
CAPES / Este trabalho apresenta a adaptação do código Geant4 para conversão de imagens DICOM (Digital Imaging and Communications in Medicine) de crânio, obtidas em tomografia convencional (CT), em um phantom antropomórfico virtual. O trabalho foi baseado no exemplo médico denominado “Código Dicom”, disponibilizado pelos desenvolvedores do código Geant4. Durante a execução do trabalho foram feitas reestruturações no exemplo “Código Dicom” para a conversão direta de imagens tomográficas em um phantom virtual. Foram retirados do código todos os passos referentes aos eventos físicos nucleares. Foi reformulado o arquivo DicomHandler.cc para não realizar a compressão dos pixels da imagem de CT. Em seguida foi realizada a conversão direta de imagens tomográficas, de um phantom físico de polietileno (PEAD) com núcleo central de acrílico e de um crânio real humano, em phantoms virtuais para o código Geant4. Os resultados demonstraram que com este código é possível a reconstrução de áreas anatômicas com geometrias complexas, partindo do uso de imagens tomográficas reais. / This work presents the adaptation of the Geant4 code for converting DICOM (Digital Imaging and Communications in Medicine) images of a skull, obtained in conventional tomography (CT), into a virtual anthropomorphic phantom. The work was based on the medical example named "Dicom Code" provided by the developers of the code Geant4. During the execution, restructurings using the "Dicom Code" example were made to achieve the direct conversion of tomographic images into a virtual phantom. All the steps referring to nuclear physical events were removed. The file DicomHandler.cc was reformulated in order to avoid the pixels compression of the CT image. The CT images of a physical polyethylene (PEAD) phantom with acrylic core and a real human skull were then converted into virtual phantoms for the code Geant4. The results showed that with this code, it may be possible the reconstruction of anatomical areas with complex geometries, based on the use of real tomographic images.
|
9 |
Fusão de modelos 3D com imagens térmicas para aplicações médicasKrefer, Andriy Guilherme 26 June 2015 (has links)
CNPq; CAPES / A termografia permite a visualização de valores de temperatura de um corpo por meio de imagens. Na área médica, encontra aplicações em oncologia, análise de queimaduras, doenças vasculares, doenças respiratórias, doenças de pele e como forma geral de verificação da vitalidade dos tecidos. A termografia 3D consiste de uma malha 3D com uma textura térmica projetada em sua superfície, oferecendo uma visualização mais precisa dos padrões de temperatura das estruturas anatômicas. Propõe-se, por meio do presente trabalho, um sistema capaz de combinar imagens termográficas 2D com sua malha 3D correspondente e, como resultado, entregar uma imagem termográfica 3D para aplicações médicas. Para isso foram utilizadas as técnicas de Otimização por Enxame de Partículas (PSO) e de reconstrução 3D Structure from Motion (SfM). Diferentemente de outros trabalhos na literatura, a malha 3D e as imagens térmicas não precisam ser adquiridas simultaneamente, não sendo necessário um arranjo mecânico dedicado. A malha 3D pode ter origem em um scanner 3D ou em uma imagem de ressonância magnética, por exemplo. Para avaliar os resultados, um phantom, isto é, um objeto estático de avaliação, com propriedades conhecidas, foi construído. Para tal, uma técnica inédita, utilizando placas de circuito impresso foi desenvolvida. Como resultado, comparações entre a saída do método proposto e o phantom, apresentaram um erro máximo de 3,73 mm e médio de 1,41 mm, com desvio padrão de 0,74 mm, em um phantom de 100 x 150 x 103,2 mm. / Thermography is an imaging method that allows temperature visualization of various regions of an object. In medicine, it finds applications related to oncology, burn trauma, vascular, respiratory and skin diseases, and as a general tissue vitality checking tool. 3D thermography adds tridimensional information to the conventional 2D thermography. It is made from a 3D mesh wrapped by thermal texture, enabling a more precise visualization of thermal patterns of anatomical structures. We propose a system capable of combining 2D thermal images with their corresponding 3D mesh, delivering a 3D thermogram for medical applications as a result. We used Particle Swarm Optimization (PSO) for mesh alignment and Structure from Motion (SfM) for 3D reconstruction in the present method. In contrast to most research found in the literature, the 3D mesh and the thermal images do not need to be acquired simultaneously, and a mechanical support for the thermal camera and the 3D scanner is not required. The 3D mesh may be acquired, for instance, from a 3D scanner or a magnetic resonance imaging machine. In order to evaluate the results, a phantom, that is, a static assessment object of known properties has been built. For this purpose, a novel technique using printed circuit boards has been developed. As a result, comparison between the output of the method and the phantom shows a maximum error of 3.73 mm and a mean error of 1.41 mm with 0.74 mm of standard deviation in phantom of 100 x 150 x 103.2 mm. / 5000
|
10 |
Fusão de modelos 3D com imagens térmicas para aplicações médicasKrefer, Andriy Guilherme 26 June 2015 (has links)
CNPq; CAPES / A termografia permite a visualização de valores de temperatura de um corpo por meio de imagens. Na área médica, encontra aplicações em oncologia, análise de queimaduras, doenças vasculares, doenças respiratórias, doenças de pele e como forma geral de verificação da vitalidade dos tecidos. A termografia 3D consiste de uma malha 3D com uma textura térmica projetada em sua superfície, oferecendo uma visualização mais precisa dos padrões de temperatura das estruturas anatômicas. Propõe-se, por meio do presente trabalho, um sistema capaz de combinar imagens termográficas 2D com sua malha 3D correspondente e, como resultado, entregar uma imagem termográfica 3D para aplicações médicas. Para isso foram utilizadas as técnicas de Otimização por Enxame de Partículas (PSO) e de reconstrução 3D Structure from Motion (SfM). Diferentemente de outros trabalhos na literatura, a malha 3D e as imagens térmicas não precisam ser adquiridas simultaneamente, não sendo necessário um arranjo mecânico dedicado. A malha 3D pode ter origem em um scanner 3D ou em uma imagem de ressonância magnética, por exemplo. Para avaliar os resultados, um phantom, isto é, um objeto estático de avaliação, com propriedades conhecidas, foi construído. Para tal, uma técnica inédita, utilizando placas de circuito impresso foi desenvolvida. Como resultado, comparações entre a saída do método proposto e o phantom, apresentaram um erro máximo de 3,73 mm e médio de 1,41 mm, com desvio padrão de 0,74 mm, em um phantom de 100 x 150 x 103,2 mm. / Thermography is an imaging method that allows temperature visualization of various regions of an object. In medicine, it finds applications related to oncology, burn trauma, vascular, respiratory and skin diseases, and as a general tissue vitality checking tool. 3D thermography adds tridimensional information to the conventional 2D thermography. It is made from a 3D mesh wrapped by thermal texture, enabling a more precise visualization of thermal patterns of anatomical structures. We propose a system capable of combining 2D thermal images with their corresponding 3D mesh, delivering a 3D thermogram for medical applications as a result. We used Particle Swarm Optimization (PSO) for mesh alignment and Structure from Motion (SfM) for 3D reconstruction in the present method. In contrast to most research found in the literature, the 3D mesh and the thermal images do not need to be acquired simultaneously, and a mechanical support for the thermal camera and the 3D scanner is not required. The 3D mesh may be acquired, for instance, from a 3D scanner or a magnetic resonance imaging machine. In order to evaluate the results, a phantom, that is, a static assessment object of known properties has been built. For this purpose, a novel technique using printed circuit boards has been developed. As a result, comparison between the output of the method and the phantom shows a maximum error of 3.73 mm and a mean error of 1.41 mm with 0.74 mm of standard deviation in phantom of 100 x 150 x 103.2 mm. / 5000
|