Optimalizace částečných výbojů UG 500R a UG550 pro napěťovou hladinu 17,5 kV / Optimization of partial discharges UG500R and UG550 for 17.5 kV voltage levelBajánek, Tomáš January 2013 (has links)
Master’s thesis deals with the optimization of partial discharges in switchgears ABB UniGear 500R and ABB UniGear 550 for 17,5 kV voltage level. It contains a description of the measurement method of partial discharges in metal enclosed medium voltage switchgears, analysis of the places where it may lead to formation of partial discharges and project of optimization of partial discharges in switchgears ABB UniGear 500R and ABB UniGear 550 for 17,5 kV voltage level.
|
12 |
On-line partial discharges detection in conversion systems used in aeronautics / Détection on-line des décharges partielles dans des systèmes de conversion utilisés en aéronautiqueCella, Benjamin 02 December 2015 (has links)
Le concept de l'avion plus électrique a conduit les industriels à focaliser une partie de leurs efforts sur les risques liés à l'utilisation de la haute tension dans un environnement sévère (Basse pression, large plage de température et d'humidité …). Les risques associés sont l'existence et le développement de décharges partielles conduisant à terme à la défaillance du système dans lequel, elles se produisent. Considérant cette problématique, le groupe Liebherr Elektronik GmbH, en collaboration avec le laboratoire Laplace, a lancé l'étude d'une méthode permettant de détecter les décharges partielles dans des convertisseurs destinés à des applications aéronautiques. Ce sont les résultats de ce travail qui font l'objet de cette thèse. La première partie fait état des connaissances actuelles sur les décharges partielles, de leur nature physique aux méthodes de détection utilisées. Dans la seconde partie, trois phases de mesures validant l'efficacité de la méthode étudiée sont présentées et leurs résultats sont discutés. Enfin, dans une troisième partie, les conclusions de nos travaux et leurs perspectives sont présentées. / The more electrical airplane concept led industrial companies to focus a part of their efforts on risks linked to the use of high voltage in a severe environment (Low pressure, wide range of temperature and humidity …). Associated risks are the existence and the growing of partial discharges ultimately leading to the breakdown of the system in which they occur. Considering this problematic, the Liebherr Elektronik GmbH group, in collaboration with the Laplace laboratory, launched the study of a method allowing partial discharges detection in converters intended to be used in aeronautical applications. The results of this work are the subject of this thesis. The first part brings the status of the current knowledge about partial discharges from their physical nature to the detection methods which are used. In the second part, three measurement phases assessing the efficiency of the studied method are introduced and their results discussed. Finally, in the third part, the conclusionsof our works and their perspectives are presented.
|
13 |
[en] A DIAGNOSTICS SYSTEM OF HIGH VOLTAGE POWER APPARATUS BASED IN PARTIAL DISCHARGES OCURRENCE / [pt] UM SISTEMA DE DIAGNÓSTICO DE EQUIPAMENTOS ELÉTRICOS DE ALTA TENSÃO COM BASE NA OCORRÊNCIA DE DESCARGAS PARCIAISHELIO DE PAIVA AMORIM JUNIOR 13 December 2001 (has links)
[pt] Os equipamentos elétricos de alta tensão são peças
fundamentais na produção industrial. Porém, os sistemas de
isolamento são os que mais apresentam problemas ao longo da
vida útil dos nossos equipamentos. Suas propriedades
dielétricas são alteradas ao longo do tempo e, desta forma
devem ser monitoradas. Dentre as principais anomalias
acometidas aos sistemas de isolamento, estão as Descargas
Parciais (DP).Elas são resultado do rompimento da rigidez
dieétrica do material isolante submetido a um intensivo
campo elétrico . Até alguns anos atrás, em virtude da
existência dos mecanismos de medição que possibilitassem o
armazernamento de dados, muito pouco se efetuava para o
acompanhamento das condições apresentadas pelos sistemas de
isolamento.Com advento de sistemas digitais,esta limitação
foi vencida. No entanto, a obtenção de dados reais e sua
posterior avaliação são mecanismos que ainda carecem de um
bom número de anos de experiência para sua elucidação. Esse
fato advém,principalmente, da dificuldade em obtê-los .Como
forma de contornar problema de falta de dados reais, foram
desenvolvidas as célualas que têm como características
simular os principais tipos de defeitos existentesnos
sistemas de isolamento de alta tensão.Essas células são
isoladas por materiais dielétricos idênticos ao que são
usados em equipamentos elétricos reais. Dessa forma, foi
possível a simulação de defeitos e a posterior aquisição,
através do método eletromagnético de medição de DP, de um
número suficiente de dados. Esses dados foram,então,
aplicados no ajuste do sistema de reconhecimento de padrões
de DP, onde se faz uso da teoria fractal, como um mecanismo
de compactação de dados, por meio das grandezas fractais
denominadas de dimensão fractal e lacunaridade, e também
das redes neurais artificiais, com a utilização de um
algoritmo supervisionado através do modo de treinamento
back-propagation.Essa etapa,denominada de laboratorial, foi
de fundamental importância para obtenção de conhecimento
experimental bastante útil para a aplicação em ambientes
reais.Outra fonte de informação também foi disponibilizada
e se refere aos níveis de gases encontrados nas amostras de
óleo colhidas junto aos transformadores de potência. Esta
análise, conhecida como análise cromatográfica,baseia-se na
existência de determinados tipos de gases para apontar o
tipo de anomalia acometida ao sistema de isolamento do
equipamento elétrico.Embora existam alguns métodos capazes
de realizar tal diagnóstico, a tese fez uso das
informações de um especialista.Essas afirmações foram
então empregadas em um sistema neuro-fuzzy hierárquico, que
tem como fundamento a extração de regras que relacionam os
níveis de gases obtidos pela cromatografia gasosa com o
tipo de anomalia existente no sistema de isolamento .Após
esse processo um conjunto de transformadores de potência
reais foi monitorado através de técnicas de cromatografia e
do método eletromagnético.As duas técnicas, portanto, são
usadas para estimar a ocorrência de DP nos sistemas de
isolamento e, cosequentemente, o nível de degradação dos
mesmos.Desta forma, a tese apresenta um sistema de
diagnóstico que se utilizada de dados internos ao sistema
de isolamento dos equipamentos elétricos baseados na
ocorrência de DP. Esse sistema indica, ao seu final, um
conceito sobre o atual estado operativo do mesmo, podendo
este ser utilizado em um planejamento mais adequado que
previna perdas intempestivas. A avaliação de desempenho do
modelo, tanto laboratorial quanto em campo, apresentou
ídices elevados, culminando em uma confirmação visual
interna de um equipamento real, que comprova a eficiência e
a importãncia do sistema. / [en] High voltage (HV) power apparatus are fundamental parts in
the industrial process. It is also well Known that
electrical insulation systems are the parts that present
more problems through the life cycle of an HV apparatus.
The dielectric properties of materials are altered during
operation time and for this reason they should be
monitored. Among the main anomalies that can affect the
insulation systems are the Partial Discharges (PD). They
are result of a partial failure of the dielectric rigidity
of the insulating material submitted to an intense electric
field.Until recently, probably due to the inexistence of
measurement mechanisms that made possible the storage of
data, very a little could be done to accompany the actual
condition of insulation systems. With the coming of digital
systems, this limitation was overcome.However, the
obtention of real data and their subsequent evaluation are
mechanisms that still will demand a good number of years
of experience to perfect . This fact occurs, mainly, due to
the difficulty in obtaining those data .As a way to the
problem of lack of real data, special cells development
with the purpose of simulating the principal types of
defects that occur in HV insulation equipment . In that
way, it was possible to do both the simulation of the
defects and the measurement and acquisition, through the
electromagnetic measurement method, of an expressive number
of data. Those data were used to adjust a system of pattern
recognition of PD, using artificial neural networks, where
it is also made use of the fractal theory, as a mechanism
of data compression, by measures of fractal dimension and
lacunarity. That stage, denomited laboratory, was of
fundamental importance to the obtention of experimental .
Knowledge very useful to the development of real operating
systems .Another source of information that was also
available refers to the levels of gases found in oil
samples from the interior of power transformers. This
analysis, known as analysis of dissolved gases or
chromatography, is based on the existence of certain types
of gases as an indication of the type of anomaly on the
electrical insulation system. Although some mehods exist,
capable of accomplishing such diagnosis, the thesis made
use of a specialist`s information. Those statements were
used then in a hierarchical neuro-fuzzy model, designed
method, with the type of anomaly existent in the
insulation system. After that process, a real sample of
operating HV power apparatus was monitored using the two
analysis techniques, the chromatography and the
electromagnetic method of PD measurement.Therefore these
two techniques, are used to estimate the PD activity in
the insulation systems and, consequently, their level of
degradation . In resume the thesis presents a diagnosis
system that makes use of internal data from the electrical
insulation system with base in the PD occurrence. That
system indicates, at the end, a concept of its current
operative state, being able to be used in a more
appropriate planning in order to prevent inopportune
losses. The evaluation of the model, as much of simulating
as in field, present high indexes and a visual confirmation
intern of a real equipment, that proves the efficiency and
the importance of system.
|
14 |
Odhalení klíčových faktorů vzniku neshodných kusů v sériové výrobě / Detection of key factors of non-standard pieces in series productionBeňo, Tomáš January 2020 (has links)
The presented thesis deals with the issue of statistical quality control of a specific production process. The thesis presents a range of statistical tools that can be used to identify the factors causing a high proportion of non-standard pieces. The diploma thesis practically introduces the application of these quality management tools to the production process characterized by an increased proportion of non-standard pieces, in which the factors causing their occurrence are unknown, and as following the thesis in detail introduces the approach how to detect these factors. The last part of the work summarizes the recommendations handed over to the company in order to verify the conclusions of the thesis.
|
15 |
Endurance et tenue diélectrique de l’isolation de câbles électriques pour l’aéronautique / Endurance and dielectric strength of electrical cable insulation for aeronauticsKaradjian, Marine 18 December 2018 (has links)
Dans la perspective de l’aéronef « plus électrique », l’augmentation de puissance électrique embarquée se traduit par une augmentation de tension. Les tensions envisagées aujourd’hui sont inférieures à 1000 V DC. Mais des valeurs plus élevées peuvent être considérées pour le futur. Il est donc indispensable d’étudier les dégradations prématurées induites par cette élévation de tension sur les équipements existants. Ce travail de thèse, portant spécifiquement sur les câbles aéronautiques, constitue une contribution à cette étude. Les câbles examinés, constitués d’une âme multibrins sur laquelle sont rubanées des couches de PTFE et PI, ont subi différents vieillissements accélérés thermiques statiques et dynamiques, sous humidité, et ce sans ou avec contrainte électrique. Certains vieillissements ont été effectués sur une durée supérieure à 9000 heures. Les décharges partielles (DP) ont été étudiées sur ces câbles en termes de tension d’apparition PDIV et RPDIV. Ces DP peuvent intervenir à l’extérieur ducâble mais également à l’intérieur (pour des tensions plus élevées) dans les interstices d’air entre l’isolant et les brins conducteurs. Cette localisation a été confirmée par un modèle électrostatique. L’effet du vieillissement n’a pu être constaté que sur les décharges internes, avec dans certains cas une réduction significative des valeurs de RPDIV.Des analyses physicochimiques du système d’isolation électrique ont été effectuées ainsi que des radiographies par rayons X. Des modifications chimiques des interfaces du système d’isolation interviennent au cours des vieillissements. Pour les vieillissements les plus poussés (après 9000h sous contrainte thermique à 240°C), ces modifications résultent en la formation de cavités où des DP peuvent prendre place. Enfin, des mesures électrostatiques de potentiel de surface (déclin et retour après neutralisation) ont mis en évidence, bien avant l’observation de cavités, une augmentation de conductivité d’une des couches de l’isolation. / In future "more electric" aircraft, the increase in on board electrical power will result in an increase in voltage. The voltages envisaged today are lower than 1000 V DC, but higher values can be considered in the medium to long term. It is therefore essential to study possible premature degradation of existing equipment induced by this rise in voltage. This thesis work, specifically on aeronautical cables, is a contribution to this goal. The examined cables, consisting of a multi-stranded core on which PTFE and PI layers are wound, have undergone various static and dynamic accelerated thermal aging, under humidity, without or with electrical stress. Aging has been carried out in some cases for more than 9000 hours. Partial discharges (DP) were studied on these cables in terms of the appearance voltage PDIV and RPDIV. These DPs can occur outside the cable but alsoinside (for higher voltages) in the air gaps between the insulation and the conductive strands. This location has been confirmed by an electrostatic model. The effect of aging was only found in the case of internal discharges, with in some cases a significant reduction in RPDIV values.Physicochemical analyses of the electrical insulation system were carried out as well as x-ray radiography. Chemical modifications of the interfaces of the insulation system occur during aging. For the most advanced aging (after 9000h under thermal stress at 240°C), these changes result in the formation of cavities where DP can then take place. Finally, electrostatic measurements of surface potential (decline and return after neutralization) have shown, well before the observation of cavities, an increase in conductivity of one of the layers of the insulation.
|
16 |
[en] A STUDY RELATED WITH THE ISOLATION CONDITION OF HIGH TENSION ROTATING ELECTRIAL MACHINES / [pt] ESTUDO SOBRE O ESTADO DO ISOLAMENTO DE MÁQUINAS ELÉTRICAS ROTATIVAS DE ALTA TENSÃOHELIO DE PAIVA AMORIM JUNIOR 14 December 2005 (has links)
[pt] O Monitoramento do Sistema de Isolamento em Máquinas
Elétricas de Alta Tensão representa um avanço no que diz
respeito ao planejamento operacional de uma indústria. Com
posse de dados on-line referentes às condições
apresentadas pelos isolamentos, as devidas precauções
podem ser tomadas, evitando danos maiores. O trabalho
apresentado tem como objetivo principal analisar um
sistema de monitoramento desenvolvido pela CEA (Canadian
Electrical Association), com suporte técnico da Ontario
Hydro. O sistema chamado PDA (Partial Discharge Analyzer)
mede, através de acopladores permanentes ou portáteis
(capacitores), as Descargas Parciais nos enrolamentos
estatóricos de grande máquinas de alta tensão. A
quantificação exata das Descargas Parciais são indicadas
das reais condições do isolamento. A análise do aparelho
foi realizada em conjunção aos dados obtidos, tendo como
referência a Companhia Siderúrgica Nacional (CSN). A
partir de tais dados, é possível demostrar em que estágio
atual de aproveitamento estamos em relação à utilização de
tal aparelho e quais são os passos futuros para melhor
compreensão das medidas. / [en] The Monitoring of te Isolation System in High Tension
Electrical Machines represents na advance in what concerns
the operational planning of na industry. Knowing the on-
line data referring to the conditions presented by the
isolations, the necessary cautions can be taken, avoiding
bigger damages.
This work has as the main aim to analyze a monitoring
system developed by the CEA (Canadian Electrical
Association). The system is called PDA ( Partial Discharge
Analyzer) and measures, through permanent or portable
couplers (capacitors), the Partial Discharges is indicator
of the isolation real conditions.
The appliance analyses was made with the obtained data,
having as reference the CSN. With this data, it is
possible to show in what profiting stage of appliance and
which are the future steps for a better comprehension of
the measures.
|
17 |
Non-conventional sensors for measuring partial discharge under DC electrical stressRostaghihalaki, Mojtaba 25 November 2020 (has links)
Partial discharge (PD) is a micro discharge that occurs in defected regions within the insulating media. As these discharges are the main culprits that cause dielectric material aging, PD measurements have been used for assessing insulating materials, including solids, liquids, and gases for power applications. There are various methods and sensors available for measuring PD sensitive to specific characteristics and operable over a wide range of frequencies. Most PD measurement techniques provide patterns that enable PD interpretation more comfortable for users. For example, in AC applications, the phase-resolved partial discharge (PRPD) technique provides identifiable patterns for distinguishing various types of PDs. However, the establishment of meaningful patterns to multiple types of PD in DC systems requires more sensitive and accurate measurements of individual PD pulses with noise rejection functionality due to the lack of phase-resolved information. Investigating of the transient phenomena such as individual PD pulses requires well-designed circuits with sufficiently large bandwidths. Waveshapes can be easily disturbed by background noise and deformed by the frequency response of measuring circuits and data acquisition systems (DAQ). Noises are unwanted disturbances that could be suppressed by suitable filters or mathematical methods. Measurement circuits and DAQ systems consist of transmission lines, sensors, cables, connectors, DAQ hardware, and oscilloscopes. Therefore, matching the impedance of all components guarantees a reflectionree path for traveling signals and addresses most of the challenges relevant to transient measurements. In this dissertation, we proposed and designed an appropriate testbed equipped with high bandwidth transmission line and electromagnetic field sensors suitable for investigating PD under DC electrical stresses. We comprehensively used finite element analysis simulations through the COMSOL Multiphysics software to design the dimensions and evaluate the frequency response of the testbed, transmission line, and electromagnetic sensors. Furthermore, based on the new testbed, DC PD measurements were performed using conventional and non-conventional sensors. Finally, various types of DC PD were statistically classified based on the proposed testbed.
|
18 |
Effects of Harmonic Voltage Distortion on Partial Discharge Characteristics on Polymeric Insulation FoilLinde, Thomas, Schlegel, Stephan 21 November 2024 (has links)
The partial discharge (PD) characteristics of polymeric insulation foil are investigated under harmonic distorted voltage waveforms. Distorted voltage waveforms can cause intensified aging, leading to preliminary insulation failure, especially when PD are present. The exact mechanism in which way harmonic distortion influences the PD activity and hence the degradation of e.g. polymeric insulation is not yet clear. The contribution presents results of parameter measurements of surface discharges on polyethylen terephtalat (PET) insulation foil. Voltage waveforms with different superimposed harmonic voltages up to 31st order and total harmonic distortions up to 20% but constant peak voltage are utilized to isolate principal influencing factors on the PD activity. The measurements show that the shape of the voltage waveform, expressed by a shape factor, has a significant effect on the apparent charge and repetition rate as well as the phase interval per period in which PD are present. Hereby, the frequency of the superimposed harmonic affects the PD activity more than the total harmonic distortion. The implications of the obtained measurement results are discussed in the context of intensified degradation and hence accelerated aging of polymeric insulation systems.
|
19 |
Detecção acústica de descargas parciais com transdutor piezoelétrico / Acoustic detection of partial discharges with piezoelectrets transducersPalitó, Thamyres Tâmulla Cavalcante 12 March 2015 (has links)
Os equipamentos elétricos instalados em linhas de transmissão e distribuição de energia são normalmente submetidos a condições anormais e intensos campos elétricos, que, eventualmente, levam, entre outros fenômenos, as descargas parciais (DPs). Estas descargas têm sido apontadas como uma das principais causas de falhas de equipamentos e envelhecimento precoce. Portanto, detectar DPs se tornou uma questão importante na busca de uma energia elétrica eficiente e confiável. No que se refere a detecção de DPs existem vários sensores que podem ser aplicados, a exemplos: óptico, magnético ou acústico, e cada um deles apresentando vantagens particulares e limitações. Uma das desvantagens de tais sensores é o custo elevado, o que restringe o monitoramento de DPs no âmbito da distribuição de energia mais especificamente em transformadores de potência. Embora, se o foco do monitoramento é apenas detectar a ocorrência de DPs, uma nova classe de sensores acústicos implementados com piezoeletretos pode ser uma alternativa econômica viável. Deste modo, nesta dissertação, foi investigado o comportamento acústico de tais transdutores expostos a diferentes condições de DPs, onde o sensor piezoelétrico foi utilizado na detecção de DPs produzidas por uma configuração de eletrodos ponta - ponta separados por diferentes gaps de ar (único ou múltiplo) e excitado por altas tensões alternadas. As amplitudes dos sinais registrados foram correlacionadas com a distância do gap e com a amplitude da tensão aplicada. A partir dos resultados obtidos foi possível observar que a intensidade do som das DPs, capturado com o transdutor piezoelétrico, está relacionada com o tamanho do gap e da amplitude da tensão, como relatado na literatura. / Electrical equipment installed in power transmission and distribution lines are usually subjected to abnormal conditions and intense electric fields, which eventually lead, among others phenomena, to partial discharges (PDs). These discharges have been pointed as one of the main causes of equipment failures and premature aging. Therefore, detect PDs became an important issue in the prospect of efficient and reliable electric energy. Concerning PD detection there are several sensors that can be employed e.g. optical, magnetic or acoustic, and each of them presenting particular advantages and limitations. One of the drawback of such sensors is their elevated cost, which restricts the PD monitoring within the distribution of energy more specifically in power transformers. Although, if the intention of monitoring is only to detect the PD occurrence a new class of acoustic sensors implemented with piezoelectrets may be a feasible economic alternative. Therefore, in this work was investigated the acoustic behavior of such transducers exposed to different PD conditions, for instance, the piezoelectret sensor was employed on the detection of PD produced by a single or multiple point-to-point electrode setup with different air gaps excited by high AC voltages. The recorded signals amplitudes were correlated with the gap distance and voltage amplitude applied. Based on the results obtained it was observed that the intensity of the DPs sound, captured with the piezoelectric transducer, is related to the size of the gap and voltage amplitude, as reported in the literature.
|
20 |
Detecção acústica de descargas parciais com transdutor piezoelétrico / Acoustic detection of partial discharges with piezoelectrets transducersThamyres Tâmulla Cavalcante Palitó 12 March 2015 (has links)
Os equipamentos elétricos instalados em linhas de transmissão e distribuição de energia são normalmente submetidos a condições anormais e intensos campos elétricos, que, eventualmente, levam, entre outros fenômenos, as descargas parciais (DPs). Estas descargas têm sido apontadas como uma das principais causas de falhas de equipamentos e envelhecimento precoce. Portanto, detectar DPs se tornou uma questão importante na busca de uma energia elétrica eficiente e confiável. No que se refere a detecção de DPs existem vários sensores que podem ser aplicados, a exemplos: óptico, magnético ou acústico, e cada um deles apresentando vantagens particulares e limitações. Uma das desvantagens de tais sensores é o custo elevado, o que restringe o monitoramento de DPs no âmbito da distribuição de energia mais especificamente em transformadores de potência. Embora, se o foco do monitoramento é apenas detectar a ocorrência de DPs, uma nova classe de sensores acústicos implementados com piezoeletretos pode ser uma alternativa econômica viável. Deste modo, nesta dissertação, foi investigado o comportamento acústico de tais transdutores expostos a diferentes condições de DPs, onde o sensor piezoelétrico foi utilizado na detecção de DPs produzidas por uma configuração de eletrodos ponta - ponta separados por diferentes gaps de ar (único ou múltiplo) e excitado por altas tensões alternadas. As amplitudes dos sinais registrados foram correlacionadas com a distância do gap e com a amplitude da tensão aplicada. A partir dos resultados obtidos foi possível observar que a intensidade do som das DPs, capturado com o transdutor piezoelétrico, está relacionada com o tamanho do gap e da amplitude da tensão, como relatado na literatura. / Electrical equipment installed in power transmission and distribution lines are usually subjected to abnormal conditions and intense electric fields, which eventually lead, among others phenomena, to partial discharges (PDs). These discharges have been pointed as one of the main causes of equipment failures and premature aging. Therefore, detect PDs became an important issue in the prospect of efficient and reliable electric energy. Concerning PD detection there are several sensors that can be employed e.g. optical, magnetic or acoustic, and each of them presenting particular advantages and limitations. One of the drawback of such sensors is their elevated cost, which restricts the PD monitoring within the distribution of energy more specifically in power transformers. Although, if the intention of monitoring is only to detect the PD occurrence a new class of acoustic sensors implemented with piezoelectrets may be a feasible economic alternative. Therefore, in this work was investigated the acoustic behavior of such transducers exposed to different PD conditions, for instance, the piezoelectret sensor was employed on the detection of PD produced by a single or multiple point-to-point electrode setup with different air gaps excited by high AC voltages. The recorded signals amplitudes were correlated with the gap distance and voltage amplitude applied. Based on the results obtained it was observed that the intensity of the DPs sound, captured with the piezoelectric transducer, is related to the size of the gap and voltage amplitude, as reported in the literature.
|