• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 318
  • 9
  • 9
  • 9
  • 9
  • 5
  • 4
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • Tagged with
  • 321
  • 321
  • 223
  • 222
  • 112
  • 97
  • 78
  • 44
  • 40
  • 38
  • 38
  • 25
  • 24
  • 24
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
251

Avaliação dos mecanismos envolvidos na vasodilatação dependente do endotélio em aorta de camundongos tratados com isoproterenol. / Evaluation of the mechanisms involved on the endothelium-dependent vasodilation in aorta of isoproterenol-treated mice.

Oliveira, Angelo Bernak de 20 February 2014 (has links)
Esta dissertação investigou os mecanismos envolvidos na vasodilatação focando no papel das cavéolas e na possível interação com a isoforma endotelial da sintase de óxido nítrico (eNOS)/ óxido nítrico e neuronal (nNOS)/ peróxido de hidrogênio (H2O2) em aorta de camundongos tratados com isoproterenol (ISO). Anéis de aorta foram montados em banho de órgãos para medida de tensão isométrica. A expressão das proteínas foi avaliada a partir da técnica de Western blot. Os resultados demonstraram que o tratamento com ISO: 1) não modifica nem a vasodilatação à acetilcolina (ACh) nem ao nitroprussiato de sódio; 2) aumenta a dependência das cavéolas na resposta vasodilatadora à ACh e ao ionóforo de cálcio e a expressão proteica da caveolina-1, mas não da caveolina-3; 3) aumenta a modulação das NOS, principalmente a nNOS, à ACh; 4) aumenta a participação do H2O2 na vasodilatação à ACh e 5) aumenta a expressão de proteínas da defesa antioxidante. Conclui-se que a hiperativação β-AR com ISO ativa mecanismos vasodilatadores compensatórios em resposta à ACh nas aortas de camundongos. / The aim of this thesis was to investigate the mechanisms involved on the endothelium-dependent vasodilation focusing on the role of caveolae and the possible interaction between endothelial nitric synthase (eNOS)/ nitric oxide and neuronal (nNOS)/ hydrogen peroxide (H2O2) in aorta of ISO-treated mice. Aortic rings were mounted in an organ bath for measurement of isometric tension. The expression of proteins was evaluated using Western blot. The results demonstrated that ISO treatment: 1) did not change acetylcholine (ACh) or NO donor-induced relaxation; 2) increases the caveolae participation in ACh and calcium ionophore-induced relaxation and caveolin-1 protein expression, while did not change caveolin-3; 3) increases the constitutive NOS modulation to ACh-induced relaxation, mainly through nNOS; 4) increases the H2O2 involvement on the vasodilation-induced to ACh and 5) increases the antioxidant proteins. It is concluded that β-AR hyperactivation ISO active vasodilators compensatory mechanisms in response to ACh in the aortas of mice.
252

Efeito dos agentes clareadores sobre o esmalte dental, a resina composta e a interface dente/restauração / Effect of bleaching agents on the dental enamel, the composite resin and the tooth/restoration interface

Abe, Andréa Tami 10 June 2014 (has links)
Este estudo in vitro teve como objetivo avaliar a dureza do esmalte dental, da resina composta, do adesivo e da camada híbrida em esmalte expostos a agentes clareadores à base de peróxido de hidrogênio a 35%, e analisar a interface dente/restauração com microscopia eletrônica de varredura (MEV). Foram utilizadas 40 coroas dentais de incisivos bovinos, que foram incluídas em resina epóxi. Uma cavidade de 2x2x2mm foi confeccionada no terço médio da face vestibular planificada de cada dente. As cavidades foram restauradas com o adesivo Adper Single Bond 2 e a resina nanoparticulada Filtek Z350 XT, e o polimento foi realizado após uma semana da confecção das restaurações. Os corpos de prova foram divididos em quatro grupos (n=10), correspondente a cada agente clareador à base de peróxido de hidrogênio a 35% utilizado (TB: Total Blanc Office; HPB: Whiteness HP Blue; HP: Whiteness HP; PO: Pola Office). A aplicação dos clareadores foi realizada 24 horas após o polimento, de acordo com as recomendações dos respectivos fabricantes. O valor do pH dos agentes clareadores foi medido no início e no final do procedimento clareador. A dureza dos substratos foi mensurada antes (inicial), imediatamente após o clareamento e após 7 dias de armazenamento em saliva artificial com o equipamento ultramicrodurômetro DUH-211S (Shimadzu). As cargas utilizadas foram de 100mN para o esmalte dental e para a resina composta, e de 10mN para o adesivo e para a camada híbrida em esmalte. Para a análise com MEV, foi confeccionado mais um corpo de prova para cada agente clareador, que foi replicado em resina epóxi a cada tempo de análise. Os testes estatísticos empregados foram a ANOVA de 2 fatores sendo 1 com vinculação (p<0,05) e o teste de Tukey. Quanto à dureza do esmalte e da camada híbrida, os corpos de prova expostos aos agentes TB, HPB e HP não apresentaram alteração da dureza nos três tempos de mensuração. O agente PO foi o clareador que apresentou o valor de pH mais baixo e o único que promoveu uma diminuição da dureza desses substratos imediatamente após sua aplicação, porém após 7 dias de armazenamento em saliva artificial a dureza retornou ao valor inicial. Nenhuma alteração foi observada quanto à dureza da resina composta e do adesivo expostos aos agentes clareadores utilizados. A análise em MEV revelou fendas entre o esmalte dental e o adesivo imediatamente após exposição à maioria dos clareadores. Pode-se concluir que o agente PO foi o único que diminuiu a dureza dos substratos dentais e o que promoveu a maior fenda na interface dente/restauração logo após sua aplicação. Nenhum clareador promoveu alteração da dureza da resina composta e do adesivo. / The aim of this in vitro study was to evaluate the hardness of the dental enamel, the composite resin, the dental adhesive and the enamel hybrid layer exposed to 35% hydrogen peroxide bleaching agents, and to analyze the tooth/restoration interface with scanning electron microscopy (SEM). Forty bovine incisor crowns were embedded in epoxy resin and then the labial surface of the teeth was flatted. One 2x2x2mm cavity was prepared on the middle third of each tooth labial surface. The cavities were restored with the adhesive Adper Single Bond 2 and the nanocomposite resin Filtek Z350 XT. After one week of storage, the restorations were polished. The specimens were divided into four groups (n=10), in correspondence to each 35% hydrogen peroxide bleaching agents used (TB: Total Blanc Office; HPB: Whiteness HP Blue; HP: Whiteness HP; PO: Pola Office). The bleaching procedure was performed 24 hours after polish, according to each manufacturer`s recommendation. The pH value of the bleaching agents was measured before and at the end of the bleaching procedure. Hardness test was performed before, immediately after bleaching and after storage in artificial saliva for 7 days, with the ultramicrohardness tester DUH-211S (Shimadzu). Indentations were performed using 100mN load for dental enamel and composite resin, and 10mN load for adhesive layer and enamel hybrid layer. For SEM analysis, one more specimen was made for each bleaching agent, which was replicated in epoxy resin at each measurement time. The statistical tests used were 2-way ANOVA and Tukey test (p<0,05). Regarding to dental enamel and enamel hybrid layer hardness, the specimens exposed to TB, HPB and HP agents did not present hardness alterations at any measurement time. The PO agent presented the lowest pH value and was the only that promoted hardness decrease on these dental surfaces immediately after application, however, after storage in artificial saliva for 7 days the hardness returned to initial value. No alteration was observed regarding to hardness of composite resin and adhesive exposed to bleaching agents. The SEM analysis revealed gaps between the dental enamel and the adhesive immediately after exposure to majority bleaching agents. In conclusion, the PO agent was the only that promoted hardness decrease on dental surfaces, and the major gap formation in tooth/restoration interface after application. No bleaching agents caused any alteration on composite resin and adhesive hardness.
253

Fabricação, caracterização do comportamento eletroquímico e aproveitamento analítico de eletrodos modificados para a determinação de peróxido de hidrogênio / Fabrication, characterization of the electrochemical behavior and analytical use of modified electrodes for the determination of hydrogen peroxide

Roselyn Millaray Castañeda Peña 04 November 2011 (has links)
Neste trabalho são apresentados resultados sobre o desenvolvimento de um sensor visando à utilização no monitoramento de peróxido de hidrogênio em amostras de reações Fenton. Superfícies eletródicas modificadas com filmes de poli-azul de metileno (PMB) e óxido de rutênio de hexacianoferrato (RuOHCF) sem e com a incorporação de nanotubos de carbono de paredes múltiplas (MWCNTs) foram utilizadas para a detecção amperométrica de peróxido de hidrogênio. O efeito da ordem de deposição do PMB e MWCNT foi avaliado por voltametria cíclica e espectroscopia de impedância eletroquímica. Estudos realizados por voltametria cíclica indicaram que a superfície modificada com PBM/MWCNTs facilita a redução catódica do peróxido de hidrogênio, processo que ocorre em 0,0 V vs. Ag/AgCl/KCl(sat). O método para a detecção de peróxido de hidrogênio apresentou uma resposta linear de 109 a 3000 &#181;mol L-1, com limite de detecção de 20,7 &#181;mol L-1 e sensibilidade de 108 &#181;A mmol-1 L cm-2. O eletrodo modificado com RuOHCF foi utilizado para a detecção amperométrica de peróxido de hidrogênio por análise em injeção em fluxo (FIA). O método apresentou uma resposta linear de 10 a 5000 &#181;mol L-1 e limite de detecção de 1,7 &#181;mol L-1. Aplicações em amostras comerciais também foram realizadas, e os resultados foram concordantes com os obtidos por método padrão. Estudos sobre o processo eletrocatalítico da reação de peróxido de hidrogênio em filmes de RuOHCF foram investigados utilizando eletrodo rotativo. A incorporação de MWCNTs na superfície eletródica também foi analisada com o filme de RuOHCF. Os resultados indicaram que a presença de MWCNTs melhorou a resposta do sensor para peróxido de hidrogênio em potenciais próximos a 0,0 V vs. Ag/AgCl/KCl(sat). A influência da quantidade de MWCNTs foi avaliada por amperometria em 0,0 V vs. Ag/AgCl/KCl(sat) na presença de peróxido de hidrogênio. O eletrodo modificado com 100 &#181;g de MWCNTs e posterior deposição do filme de RuOHCF apresentou melhores características analíticas. Obteve-se como resultado uma curva analítica em um intervalo de 0,1 a 10 mmol L-1, originando uma reta de acordo com a equação: -I (&#181;A) = 0,26 + 31,2 [H2O2] (mmol L-1), R2= 0,9999. A sensibilidade foi de 1560 &#181;A mmol-1 L cm-2 e os limites de detecção e quantificação foram estimados em 4,7 (S/N = 3) e 15,8 (S/N = 10) &#181;mol L-1, respectivamente. Comparando-se as características analíticas dos filmes de PMB e RuOHCF depositados na superfície dos MWCNTs, aquele que apresentou melhor resultado foi o eletrodo modificado com MWCNTs e RuOHCF por ter melhor limite de detecção e maior sensibilidade. Esse eletrodo modificado com MWCNTs e RuOHCF foi utilizado para monitorar o consumo de peróxido de hidrogênio em amostras de reação Fenton. Também foi avaliado o efeito da presença de Fe3+ contido no próprio processo de degradação. A interferência foi eliminada complexando o Fe3+ com oxalato. Finalmente, o eletrodo foi utilizado para monitorar a concentração de peróxido de hidrogênio na degradação de fenol e os resultados foram concordantes com os obtidos por método espectrofotométrico / This work presents results on the development of a sensor to monitor the hydrogen peroxide content in samples of Fenton reaction. The electrode surface was modified with films of poly-methylene blue (PMB) and ruthenium oxide hexacyanoferrate (RuOHCF). In some cases, multiwalled carbon nanotubes (MWCNT) were also used. The effect of the order of deposition of PMB and MWCNTs was evaluated by cyclic voltammetry and electrochemical impedance spectroscopy. The influence of immobilization of various platforms in the performance of fabricated sensors for hydrogen peroxide was also studied. Cyclic voltammetry experiments indicated that the surface modified with PMB/MWCNTs facilitates the cathodic reduction of hydrogen peroxide, a process that occurred at 0.0 V vs. Ag/AgCl/KCl(sat). The method showed a linear response from 109 to 3000 &#181;mol L-1 hydrogen peroxide. The limit of detection was estimated as 20.7 (S/N = 3) &#181;mol L-1 with a sensitivity of 108 &#181;A mmol-1 L cm-2. Electrodes modified with RuOHCF films were used for the amperometric detection of hydrogen peroxide by flow injection analysis (FIA).The method showed a linear response from 10 to 5000 &#181;mol L-1 and a detection limit of 1.7 &#181; mol L-1. Analyses of hydrogen peroxide in commercial samples were also performed, and the results agreed with those obtained by a standard method. Studies on the kinetics of the electrocatalytic reduction of hydrogen peroxide in RuOHCF films were carried out using rotating disc voltammetric. The immobilization of MWCNTs on RuOHCF films was also investigated. The results indicated that the presence of MWCNTs facilitated the electrocatalytic reduction of hydrogen peroxide at potential values near to 0.0 V vs. vs. Ag/AgCl/KCl(sat). The influence of the amount of MWCNTs was studied by amperometry at 0.0 V vs. vs. Ag/AgCl/KCl(sat) in the presence of hydrogen peroxide. The electrode modified with 100 &#181;g of MWCNTs and subsequent deposition of the RuOHCF film showed better analytical characteristics. An analytical curve ranging from 0.1 to 10 mmol L-1 hydrogen peroxide was obtained, resulting in a straight line according to the equation: -I (&#181;A) = 0.26 + 31.2 [H2O2] (mmol L-1), R2= 0.9999. The sensitivity was found to be 1560 &#181;A mmol-1 L cm-2 and the detection and quantification limits were estimated at 4.7 (S / N = 3) and 15.8 (S / N = 10) mmol L-1, respectively. Electrodes modified with MWCNTs and RuOHCF films leaded to better detection limit and sensitivity in comparison to those modified with MWCNTs and PMB. This MWCNTs and RuOHCF modified electrode was used to monitor the consumption of hydrogen peroxide in samples of Fenton reaction and the effect of Fe3+ generated in the degradation process was also examined. The interference was minimized by adding oxalate to the samples. Finally, the sensor was used to monitor the concentration of hydrogen peroxide in the degradation of phenol and the results were in agreement with those obtained by using spectrophotometry
254

Emprego de técnicas e termoanalíticas na análise de amidos nativos e modificados de mandioca

Costa, Fernanda Janaína Oliveira Gomes da 08 February 2010 (has links)
Made available in DSpace on 2017-07-21T18:53:16Z (GMT). No. of bitstreams: 1 Fernanda Janaina Oliveira Gomes da Costa.pdf: 2530982 bytes, checksum: 65f2e845c0bdca1384a01a29d20c0298 (MD5) Previous issue date: 2010-02-08 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Starch is an abundant carbohydrate in nature, can be extracted from several botanical sources and has many industrial applications, mainly in the food sector.Due to some limitations of native starch, the production of modified starch has been an alternative to overcome these restrictions and promote increase in use of this polymer. This study used techniques thermoanalitycal TG, DTA and DSC for the evaluation of thermal properties (stability, gelatinization and enthalpy). Also has been applied optical microscopy and X-ray diffraction in samples of native cassava starch, extracted in laboratory and commercial sample wich were modified by action of H2O2 in different concentrations (1, 2 and 3%) with and without addition of the catalyst FeSO4 (0,01%). The results of thermal analysis showed that the onset temperature (To) and peak (Tp), and enthalpy of gelatinization (ΔHgel) vary with the degree of oxidation. The native starch granules showed characteristic morphology and only showed small changes in morphology after treatment with H2O2 in the concentration of 3%. Through X-ray diffraction can be seen the typical crystallinity of starches and were observed few changes in the patterns of crystallinity of the modified starches. / O amido é um carboidrato abundante na natureza, pode ser extraído de diversas fontes botânicas e possui muitas aplicações industriais, principalmente no ramo alimentício. Devido a algumas limitações dos amidos nativos, a produção de amidos modificados tem sido uma alternativa para superar tais restrições e promover o aumento da utilidade deste polímero. Neste estudo foram utilizadas técnicas termoanaliticas TG, DTA e DSC para a avaliação das propriedades térmicas (estabilidade, gelatinização e entalpia). Também foram aplicadas microscopia óptica e difratometria de raios X nas amostras de amido de mandioca nativo, tanto extraídos em laboratório quanto comercial, que foram modificados pela ação de H2O2 em diferentes concentrações (1, 2 e 3%) com ou sem a adição do catalisador FeSO4 (0,01%). Os resultados da análise térmica mostraram que as temperaturas onset (To) e de pico (Tp) e a entalpia de gelatinização (ΔHgel) variam de acordo com o grau de oxidação. Os grânulos do amido nativo apresentaram morfologia característica e somente apresentaram pequenas alterações após tratamento com H2O2 na concentração de 3%. Através da difratometria de raios X pode-se perceber a cristalinidade típica de amidos e para os amidos modificados foram observadas poucas alterações nos padrões de cristalinidade.
255

AVALIAÇÃO CLÍNICA DA INFLUÊNCIA DO CAFÉ NA EFETIVIDADE DO CLAREAMENTO DENTAL / Clinical evaluation of the influence of coffee in the effectiveness of dental bleaching

Siqueira, Márcia Fernanda de Rezende 29 February 2012 (has links)
Made available in DSpace on 2017-07-24T19:22:19Z (GMT). No. of bitstreams: 1 MARCIA FERNANDA DE REZENDE SIQUEIRA.pdf: 1854900 bytes, checksum: 25353ada2c457db2da3208c5e6d94257 (MD5) Previous issue date: 2012-02-29 / The objective of this clinical study was to evaluate whether exposure to coffee during the bleaching treatment with PC 16 (Whiteness Perfect, FGM,Joinville, Santa Catarina, Brazil) affects the degree of whitening and tooth sensitivity. We selected 40 patients with central incisors darker than A2, which were divided into 2 groups (n=20): GC - control group and GE - the experimental group. For the CG was no restriction of foods with dyes and the GE patients beyond the usual coffee intake in his diet made with black coffee rinses soluble Nescafé® Tradição (Nestlé), 4 times daily for 30 seconds. For both groups we used PC 16 for a period of 3 hours daily for 3 weeks. The color scale was assessed by spectrophotometer Easyshade and in the periods: initial, during the whitening (1 st, 2 nd and 3 rd week) and postbleaching (1 week and 1 month). Patients recorded their perceptions of sensitivity through the NRS scale (0-4) and VAS. For the color analysis was performed analysis of variance (ANOVA) with repeated measures on two factors (time vs. treatment groups), time being the repeated measure (=0.05). We carried out the Tukey test for contrast of means (=0.05). The tooth sensitivity was evaluated by Fisher's exact test and the intensity of tooth sensitivity was evaluated by Mann-Whitney test (=0.05) for both scales. There effectiveness of tooth whitening over time (p <0.001). For both groups was not statistical differences in absolute risk of sensitivity between the groups (p=1.0). Most patients had mild tooth sensitivity and no statistically significant difference was detected between groups for both the NRS scale (p=0.529) and for the VAS (p=0.258). It was concluded that dental bleaching is effective for the groups studied, which makes possible the consumption of coffee during the bleaching treatment. / O objetivo deste estudo clínico foi avaliar se a exposição ao café durante o tratamento clareador com PC 16% (Whiteness Perfect, FGM, Joinville, Santa Catarina, Brasil) afeta o grau de clareamento e a sensibilidade dental. Foram selecionados 40 pacientes com os incisivos centrais mais escuros que A2, os quais foram divididos em 2 grupos (n=20): GC - grupo controle e GE - grupo experimental. Para o GC houve restrição de alimentos com corantes e para o GE os pacientes, além da ingestão usual do café na sua dieta, realizaram bochecho com café preto solúvel Nescafé Tradição (Nestlé) 4 vezes ao dia, por 30 segundos. Para os dois grupos utilizou-se PC 16% pelo período de 3h diariamente, durante 3 semanas. A cor foi avaliada através da escala Vita Classical e espectrofotômetro Vita Easyshade, nos períodos: inicial, durante o clareamento dental (1ª, 2ª e 3ª semanas) e pós-clareamento (1 semana e 1 mês). Os pacientes registraram suas percepções de sensibilidade através da escala NRS (0-4) e VAS. Para a análise de cor foi efetuada ANOVA de dois fatores (grupos vs tempo de tratamento), sendo o tempo a medida repetida (=0,05). Foi realizado o teste de Tukey para o contraste das médias =0,05). A sensibilidade dental foi avaliada pelo teste exato de Fisher e a intensidade da sensibilidade dental foi avaliada pelo teste Mann-Whitney (=0,05) para ambas as escalas. Houve efetividade do clareamento dental ao longo do tempo (p<0,001). Para ambos os grupos não foi verificada diferença estatística no risco absoluto de sensibilidade entre os grupos (p=1,0). A maioria dos pacientes apresentou sensibilidade dental leve e não foi detectada diferença estatisticamente significante entre os grupos, tanto para a escala NRS (p=0,529) como para a VAS (p=0,258). Concluiu-se que o clareamento dental foi eficaz para os grupos avaliados, o que torna possível o consumo de café durante o tratamento clareador.
256

ESTUDO CLÍNICO RANDOMIZADO DO EFEITO DO LASER TERAPÊUTICO NO CONTROLE DA SENSIBILIDADE DENTAL DURANTE E APÓS CLAREAMENTO DE CONSULTÓRIO / RANDOMIZED CLINICAL STUDY OF THE EFFECT OF THERAPEUTIC LASER IN CONTROL OF SENSITIVITY DURING AND AFTER INOFFICCE BLEACHING

Farhat, Patricia Bahls de Almeida 28 November 2013 (has links)
Made available in DSpace on 2017-07-24T19:22:30Z (GMT). No. of bitstreams: 1 Patricia Bahsl de Almeida Farhat.pdf: 1753882 bytes, checksum: f879c0192c379245e512d0acafe56801 (MD5) Previous issue date: 2013-11-28 / This study determined the effect of therapeutic laser, visible red and infrared present or not in the hybrid LED / Laser source in activation of the gel and the control of tooth sensitivity caused by in-office bleaching activated by LED light. A randomized, blinded , split-mouth was carried out in four groups (n = 16): Group LED ( GL), Group LED / low power infrared Laser ( GLL) , Group LED + infrared Laser therapy ( GLIV) and group LED + red Laser therapy ( GLVV) . Each volunteer had their upper and lower arches bleached with hydrogen peroxide to 35 % following the manufacturer's recommendations, however, with different treatments to sensitivity with an interval of 1 week between bleaching sessions and 15 days between treatments of the arcades. Tooth sensitivity was recorded in three scales: visual analog (VAS), a 5-point verbal rating scale (VRS), and the 101 points scale (NRS). The susceptibility sensitivity dates were collected during each session, immediately after the end of the sessions, up to 12 h , 24 h , 48 h , 1 month and 6 months. The color evaluation was performed before and after each treatment session and at 1 month and 6 months after bleaching with color scale (Vita Classical). Tooth sensitivity was compared between groups at each time with the Kruskal-Wallis test. The sensitivity in the same group in different periods were analyzed using the Friedman test and pair comparison with Wilcoxon. The intensity of sensitivity was similar for all groups at different times, with no statistical difference between them (p>0,05). The laser sources present in the hybrid LED / Laser was not able to prevent or reduce the dental sensitivity and not to improve the effectiveness of bleaching. The therapeutic lasers infrared and red applied after bleaching sessions also not able to prevent nor reduce tooth sensitivity caused by bleaching. All groups had their teeth whitened after 2 sessions and the color remained in assessments 1 month and 6 months. / Este estudo determinou o efeito do laser terapêutico vermelho e infravermelho, presente ou não nos equipamentos híbridos LED/Laser na ativação do gel e no controle da sensibilidade dentária, decorrente do clareamento dental realizado em consultório, ativados por luz LED. Um ensaio clínico andomizado, cego, de boca dividida foi realizado em quatro grupos (n=16): Grupo LED (GL), Grupo LED/Laser infravermelho de baixa intensidade (GLL), Grupo LED + Laser terapêutico infravermelho (GLIV) e Grupo LED + Laser terapêutico vermelho (GLVV). Cada voluntário teve suas arcadas superior e inferior clareadas com peróxido de hidrogênio 35% seguindo as recomendações do fabricante, porém, com diferentes tratamentos para sensibilidade com intervalo de 1 semana entre as sessões de clareamento e de 15 dias entre os tratamentos das arcadas. A sensibilidade dentária foi registrada em três escalas: a analógica visual (VAS), a escala verbal de 5 pontos (VRS), e a escala de 101 pontos (NRS). Os dados de sensibilidade foram coletados durante cada sessão, imediatamente após o término das sessões, até 12 h, 24 h, 48 h, 1 mês e 6 meses. A avaliação de cor foi realizada antes e após cada sessão de tratamento e com 1 mês e 6 meses após o clareamento com escala de cor (Vita Clássica). A sensibilidade dentária foi comparada entre os grupos em cada momento com o teste de Kruskal-Wallis. A sensibilidade em um mesmo grupo nos diferentes períodos foram analisadas com os testes de Friedman e comparação aos pares com Wilcoxon. A intensidade da sensibilidade foi semelhante para todos os grupos estudados nos diferentes momentos, não havendo diferença estatística entre eles (p>0,05). O Laser presente nas fontes híbridas de LED/Laser não foi capaz de evitar e nem reduzir a sensibilidade dos dentes e também não melhorou a efetividade do clareamento. Os Lasers terapêuticos infravermelho e vermelho aplicados após sessões de claremento dental, também não foram capazes de evitar e nem reduzir a sensibilidade dental provocada pelo clareamento. Todos os grupos tiveram seus dentes clareados após 2 sessões e a cor manteve-se nas avaliações de 1 mês e 6 meses.
257

EFEITO DE DOIS ANTI-INFLAMATÓRIOS E UM ANTIOXIDANTE NA PREVENÇÃO DA SENSIBILIDADE CAUSADA PELO CLAREAMENTO DENTAL / Effect of two anti-inflammatories and one antioxidant to prevent bleaching-induced tooth sensitivity

Paula, Eloisa Andrade de 05 December 2013 (has links)
Made available in DSpace on 2017-07-24T19:22:32Z (GMT). No. of bitstreams: 1 Eloisa Andrade de Paula.pdf: 11594237 bytes, checksum: 25299b2f989c0877ee886949439d03c9 (MD5) Previous issue date: 2013-12-05 / Fundação Araucária de Apoio ao Desenvolvimento Científico e Tecnológico do Paraná / The tooth bleaching has a long history of tooth sensitivity (TS). This study aimed to determine the effect of different drugs, administered perioperatively, on tooth sensitivity and the degree of tooth whitening after in-office bleaching. A triple-blind,parallel design, randomized clinical trial were conducted. In the first experiment, the participants received a placebo or 400 mg ibuprofen every 8 h while in the second experiment, they were given a placebo or 60 mg etoricoxib every 24 h. In the third experiment, they received a placebo or 500 mg ascorbic acid every 8 h. In all experiments, the first dose of the drug was administered 1 h before in-office bleaching and taken for a period 48 h. The 35% hydrogen peroxide gel (Whiteness HP Maxx, FGM) was used in three 15-min applications for three groups following the manufacturer's directions. The in-office bleaching agent was refreshed every 15 min.Two bleaching sessions, with a one-week interval, were performed on each patient. The shade evaluation were performed before and 30-days, after bleaching with a Vita Easy Shade spectrophotometer and a Vita Classical’s visual shade guide. The tooth sensitivity was recorded on three scales: the five-point verbal rating scale, the 101 points scale, and the visual analogue scale, of and in different time points up to 1 h, 24 h, 48h after bleaching. The % of patients that reported TS at least once during treatment were evaluated by Fisher`s exact and the intensity of tooth sensitivity with Mann-Whitney test. Tooth color changes were evaluated by repeated ANOVA measures and t-test. There were no significant differences in the % of patients with tooth sensitivity and color change between the groups. The lowest tooth sensitivity was observed in the 400 mg ibuprofen group only up to 1 h post bleaching. The perioperative use of ibuprofen, etoricoxib and ascorbic acid per oral route was not able to avoid bleaching-induced tooth sensitivity according to the posology and dose used in this study. However, the 400 mg ibuprofen was able to reduce the intensity of tooth sensitivity up to 1 h post bleaching. / As técnicas de clareamento dental em dentes vitalizados podem apresentar o inconveniente de causarem sensibilidade dental. Neste estudo foram realizados três experimentos com o objetivo de determinar o efeito de dois anti-inflamatórios e um antioxidante utilizados previamente e durante o procedimento de clareamento dental em consultório na sensibilidade dental e no grau de clareamento alcançado. Estes experimentos foram do tipo estudo clínico, randomizado, paralelo, controlado por placebo e triplo cego. No experimento 1, os participantes receberam placebo ou ibuprofeno 400 mg a cada 8 h. No experimento 2, os participantes receberam placebo ou etoricoxibe 60 mg a cada 24 h. No experimento 3, os participantes receberam placebo ou ácido ascórbico 500 mg a cada 8 h. Em todos os experimentos os medicamentos foram administrados 1 hora antes do início do tratamento clareador por um período total de 48 h. Em cada sessão de clareamento, o gel de peróxido de hidrogênio 35% (Whiteness HP Maxx, FGM) foi aplicado 3 vezes durante 15 minutos cada, de acordo com as instruções do fabricante e repetido depois de uma semana, seguindo o mesmo protocolo. As alterações de cor foram avaliadas antes e 30 dias após o tratamento clareador utilizando o espectrofotômetro Vita Easy Shade e a escala de cor Vita Clássica organizada por ordem de valor. Três escalas destinadas a avaliar a intensidade da dor (escala verbal de 5 pontos, escala numérica de 101 pontos e escala visual analógica) foram utilizadas para determinar o nível de sensibilidade imediatamente até 1 h, 24 h e 48 h após o tratamento de clareamento em consultório. A porcentagem de pacientes que relataram sensibilidade, ao menos uma vez durante o tratamento, e a intensidade da sensibilidade dental foram avaliadas pelo teste exato de Fischer e teste de Mann-Whitney, respectivamente. As alterações de cor dental foram determinadas por medidas repetidas ANOVA 1 critério e teste t. Não foram detectadas diferenças significativas no percentual de pacientes que apresentaram sensibilidade e nem na alteração de cor. Somente o medicamento ibuprofeno 400 mg apresentou redução da intensidade da sensibilidade na primeira hora após o tratamento clareador. Os medicamentos não foram capazes de prevenir e nem mesmo minimizar a sensibilidade dental quando administrados de acordo com a posologia e dose empregadas neste estudo.
258

Penetração do peróxido de hidrogênio em diferentes concentrações na câmara pulpar e o manejo da sensibilidade pós-operatória em clareamento dental

Parreiras, Sibelli Olivieri 27 October 2017 (has links)
Submitted by Angela Maria de Oliveira (amolivei@uepg.br) on 2017-10-27T12:19:28Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Tese Sibelli.pdf: 2029440 bytes, checksum: b214f3a9a9cf1dd6ccca621c7ae4fae6 (MD5) / Made available in DSpace on 2017-10-27T12:19:28Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Tese Sibelli.pdf: 2029440 bytes, checksum: b214f3a9a9cf1dd6ccca621c7ae4fae6 (MD5) Previous issue date: 2017-10-27 / Os objetivos deste estudo foram 1) quantificar a concentração do peróxido de hidrogênio (PH) de géis clareadores com diferentes concentrações do mesmo fabricante, 2) quantificar a concentração de PH na câmara pulpar em dentes com aplicação prévia de agentes dessensibilizantes ao clareamento de consultório e 3) avaliar o efeito de um gel dessensibilizante experimental na sensibilidade pósoperatória de pacientes submetidos a clareamento de consultório. Para os estudos 1 e 2, a quantificação de PH na câmara pulpar foi realizada por meio do método espectrofotométrico com a enzima horseradish peroxidase. No estudo 1, foram divididos aleatoriamente 90 dentes em nove grupos (n = 10) e submetidos a diferentes concentrações de gel clareador de mesmo fabricante, simulando o procedimento clareador caseiro e de consultório. No estudo 2, 50 dentes foram selecionados e os diferentes agentes dessensibilizantes: Desensibilize KF 2%, Mi Paste e Desensibilize Nano-P foram aplicados previamente ao clareamento de consultório com PH 35%. No estudo 3, 42 pacientes com os caninos com cor A2 ou mais escuros foram selecionados e divididos aleatoriamente em dois grupos: placebo (controle negativo) e tratamento. Os pacientes do grupo tratamento foram submetidos ao gel experimental a base de nitrato de potássio 5% e glutaraldeído 5% por 10 min previamente ao clareamento de consultório com PH 35%. A sensibilidade dental foi avaliada imediatamente, após 1 h, 24 h e 48 h do clareamento e registradas pelos próprios pacientes por meio das escalas numéricas de 5 pontos e visual analógica. A cor foi avaliada através da escala Vita classical, Vita Bleachedguide e espectrofotômetro Vita Easyshade (Vita Zahnfabrik, Bad Sackingen, Alemanha), inicialmente, 1 semana após cada sessão e um mês depois do término do procedimento. Os dados dos experimentos 1 e 2 foram avaliados por análise de variância (ANOVA) e teste de tukey para o contraste das médias ( = 0,05). Para a análise do risco de sensibilidade dental no estudo 3, os dados foram analisados por meio do teste Mc Nemar e a mudança de cor por teste t de Student ( = 0,05). Foi observado que a quantidade de PH que alcançou a câmara pulpar no grupo clareamento de consultório foi significativamente maior em comparação aos clareamentos caseiro (p = 0,65). Enquanto que os protocolos caseiros apresentaram resultados similares. O uso de agentes dessensibilizantes previamente ao clareamento de consultório reduziu a passagem de PH para a câmara pulpar, de forma que os dessensibilizantes Mi Paste e Nano-P tiveram menor concentração de PH na câmara pulpar (p < 0,001). Foi também possível observar que o risco de sensibilidade dentária do grupo gel dessensibilizante [31,7% (95% IC 19,6 – 46,9)] e para o grupo controle [70,7 (95% IC 55,5 – 82,3%) foram estatisticamente significante (p < 0,0001). Pode-se concluir que fatores como concentração do gel clareador e o uso prévio de agentes dessensibilizantes interferem na difusão do PH, porém a utilização do gel experimental à base de nitrato de potássio 5% e glutaraldeído 5% foi eficaz na redução da sensibilidade pós-operatória em pacientes submetidos a clareamento de consultório. / The objectives of this study were: 1) to evaluate the diffusion of hydrogen peroxide (HP) of bleaching gels with different concentrations from the same manufacturer, 2) quantify the HP concentration in the pulp chamber in teeth with prior application of desensitizing agents and 3) evaluate the effect of an experimental desensitizing gel on the postoperative sensitivity of patients undergoing in-office tooth bleaching. For studies 1 and 2, the quantification of HP in the pulp chamber was performed using the spectrophotometric method with the horseradish peroxidase enzyme. In study 1, 90 teeth were randomly divided into nine groups (n = 10) and submitted to different concentrations of whitening gel from the same manufacturer, simulating the home and in-office whitening procedure. In study 2, 50 teeth were selected at the different desensitizing agents: Desensibilize KF 2%, Mi Paste and Desensibilize Nano-P were applied prior to the office bleaching. In study 3, 42 patients with canines with A2 or darker color were selected and randomly divided into two groups: placebo (negative control) and treatment. Patients in the treatment group were submitted to 5% potassium nitrate and 5% glutaraldehyde gel for 10 min prior to bleaching with 35% hydrogen peroxide. The dental sensitivity was evaluated immediately, after 1 h, 24 h and 48 h of the bleaching and registered by the patients themselves through the numerical scales of 5 points and visual analog. The color was evaluated through the Vita classical, Vita Bleachedguide and Vita Easyshade spectrophotometer (Vita Zahnfabrik, Bad Sackingen, Germany), initially, 1 week after each session and one month after the end of the procedure. Data from experiments 1 and 2 were evaluated by analysis of variance (ANOVA) and tukey test for the means contrast ( = 0.05). For the analysis of the risk of dental sensitivity in study 3, the data were analyzed using the Mc Nemar test and the color change by Student's t-test ( = 0.05). It was observed that the amount of HP that reached the pulp chamber in the office bleaching group was significantly higher compared to home bleaching (p = 0.65). The home protocols presented similar results. The use of desensitizing agents prior to the office bleaching reduced the passage of HP to the pulp chamber, so that the desensitizers Mi Paste and Nano-P had lower HP concentrations in the pulp chamber (p < 0.001). It was also possible to observe that the risk of tooth sensitivity of the desensitizing gel group [31.7% (95% CI 19.6 - 46.9)] and for the control group [70.7 (95% CI 55.5 - 82.3%) were statistically significant (p < 0.0001). It can be concluded that factors such as concentration of the bleaching gel and the previous use of desensitizing agents interfere in the diffusion of PH, but the use of the experimental gel based on 5% potassium nitrate and 5% glutaraldehyde was effective in reducing post-operative in patients undergoing in-office tooth bleaching.
259

Aplicação de ozônio e ozônio + peróxido de hidrogênio para remoção de compostos recalcitrantes em lixiviados de aterros sanitários / Application of ozone and ozone + hydrogen peroxide to remove of recalcitrant compounds in landfill leachates

Schoenell, Elisa Kerber 28 February 2013 (has links)
Submitted by Maicon Juliano Schmidt (maicons) on 2015-07-06T14:05:57Z No. of bitstreams: 1 Elisa Kerber Schoenell.pdf: 1100203 bytes, checksum: 7fc798f66b493b73d31a96dbbf676ff3 (MD5) / Made available in DSpace on 2015-07-06T14:05:57Z (GMT). No. of bitstreams: 1 Elisa Kerber Schoenell.pdf: 1100203 bytes, checksum: 7fc798f66b493b73d31a96dbbf676ff3 (MD5) Previous issue date: 2013-02-28 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / CNPQ – Conselho Nacional de Desenvolvimento Científico e Tecnológico / FINEP - Financiadora de Estudos e Projetos / Ministério da Ciência e Tecnologia / Os lixiviados são efluentes gerados em depósitos de resíduos sólidos, através da decomposição da matéria orgânica, somados as águas de infiltração e a materiais suspensos. Ele possui compostos biodegradáveis e recalcitrantes - de difícil degradação biológica (biodegradação). Este efluente necessita de um tratamento antes de ser disposto no meio ambiente. O objetivo deste trabalho foi avaliar o uso de ozônio (O3) e peróxido de hidrogênio (H2O2) como processo oxidativo avançado (POA), visando a remoção de compostos recalcitrantes em lixiviados de aterros sanitários. Foram utilizados dois lixiviados provenientes do aterro sanitário de São Leopoldo/RS: bruto e tratado por lagoas, os quais foram tratados apenas por O3 em concentração de 29 mg/L (gerados a partir de processo corona) ou com adição de 1000 mg/L de H2O2 ao O3. Os ensaios ocorreram em escala piloto, sendo tratados 460 L de lixiviado em cada ensaio, os quais tiveram duração de 96 horas. O POA (operando com os oxidantes O3 e O3 + H2O2) mostrou-se mais eficiente no tratamento de lixiviados que tiveram as menores concentrações iniciais de DBO, DQO e COT, independente de ser lixiviado bruto ou tratado. Altas remoções de cor aparente, DQO e COT foram observadas, chegando a 99%, 88% e 66%, respectivamente. A maior remoção de carbono inorgânico foi 23%, porém o grupo que iniciou com a maior concentração desse parâmetro, obteve as maiores remoções para todos os outros parâmetros estudados. A adição de H2O2 aumentou a eficiência de remoção de todos os parâmetros analisados, porém não de forma significativa. Observou-se necessidade de tratamento complementar ao POA deste estudo. / Leachates are wastewaters generated at sites of solid waste disposal through organic matter decomposition, added to infiltration waters and suspended materials. It contains biodegradable and recalcitrant compounds - difficult to biological degradation (biodegradation). This wastewater requires treatment before being disposed in the environment. The aim of this study was to evaluate the use of ozone (O3) and hydrogen peroxide (H2O2) as advanced oxidation process (AOP), in order to removal recalcitrant compounds in landfill leachate. It was used two leachates from São Leopoldo/RS landfill: raw and treated in pounds, which were treated only with O3 at a concentration of 29 mg/L (generated from the corona process) or with addition of 1000 mg/L H2O2 to O3. The tests occurred on a pilot scale, treating 460 L of leachate in each test, which lasted 96 hours. OAP (operating with the oxidants O3 and O3 + H2O2) was more efficient in the treatment of leachate that had the lowest initial concentrations of BOD, COD and TOC (both raw and treated leachate).. High removals of apparent color, COD and TOC were observed, reaching 99%, 88% and 66%, respectively. The greater removal of inorganic carbon was 23%, but the group that started with the highest concentration of these parameter, achieve the greatest removals for all others parameters studied. The addition of H2O2 increased the efficiency of removal of all parameters, but not significantly. It was observed need of additional treatment to the POA of this study.
260

Avaliação da remoção de cor e desinfecção de lixiviados de aterro sanitário utilizando ozônio e peróxido de hidrogênio / Evaluation of color and disinfection of landfill leachate using ozone and hydrogen peroxide

Seewald, Marina Medtler 28 February 2013 (has links)
Submitted by Maicon Juliano Schmidt (maicons) on 2015-07-06T19:15:18Z No. of bitstreams: 1 Marina Medtler Seewald.pdf: 3415895 bytes, checksum: a88885e13dc4a2b54ba496bc5a0fd0b7 (MD5) / Made available in DSpace on 2015-07-06T19:15:18Z (GMT). No. of bitstreams: 1 Marina Medtler Seewald.pdf: 3415895 bytes, checksum: a88885e13dc4a2b54ba496bc5a0fd0b7 (MD5) Previous issue date: 2013-02-28 / CNPQ – Conselho Nacional de Desenvolvimento Científico e Tecnológico / FINEP - Financiadora de Estudos e Projetos / Ministério da Ciência e Tecnologia / A degradação de resíduos dispostos em aterro sanitário gera um líquido com alto potencial poluidor caracterizado por sua coloração escura, alto teor de matéria orgânica e de nitrogênio amoniacal. O lixiviado de aterro sanitário pode ainda conter micro-organismos patogênicos provenientes de resíduos contaminados com excreções humanas, representando risco à saúde. Para o tratamento de lixiviado de aterro sanitário, processos biológicos tem mostrado eficiência, especialmente na remoção de matéria orgânica. No entanto, para que se atinja eficiência de remoção desejada para atendimento à legislação, especialmente em lixiviados antigos, um pós-tratamento se faz necessário. O emprego de processos oxidativos avançados (POAs) tem mostrado boa eficiência na remoção de cor, destruição de organismos patogênicos e aumento de biodegradabilidade em efluentes recalcitrantes. O objetivo deste trabalho foi avaliar a remoção de cor e desinfecção de lixiviado de aterro sanitário através do emprego de ozônio e peróxido de hidrogênio como agentes oxidantes. Para tanto, foram realizados doze ensaios no sistema POA instalado para tratar lixiviado bruto e tratado por sistema de lagoas. Seis ensaios foram realizados somente com ozônio e os outros seis com ozônio combinado com peróxido de hidrogênio. O sistema POA possuía volume útil de 460L e os ensaios tiveram a duraçãode 96h. A concentração de ozônio (gás) foi de 29 mg/L e a de peróxido de hidrogênio (adicionado em solução líquida) foi de 1000 mg/L no lixiviado. Com a caracterização do lixiviado, verificou-se alta variabilidade das características dos lixiviados gerados no aterro sanitário de São Leopoldo. Portanto, para a discussão dos resultados de remoção de cor, optou-se por dividir os ensaios realizados por grupos, utilizando como critério para a divisão a concentração inicial de cor verdadeira no lixiviado estudado. Embora inicialmente os resultados indiquem uma similiaridade entre os oxidantes testados a análise de variância de dois fatores realizada com medidas repetidas comprovou que houve diferença entre os agentes os oxidantes utilizados na remoção de cor, sendo observado que o peróxido de hidrogênio apresentou melhor desempenho. Foi observado que quanto menor a concentração inicial de cor verdadeira, mais rápida foi sua remoção. Na desinfecção do lixiviado, os ensaios utilizando ozônio e peróxido de hidrogênio apresentaram maiores taxas de inativação de coliformes termotolerantes, sugerindo que o acréscimo do segundo oxidante foi adequada. A turbidez e matéria orgânica presentes no lixiviado não impediram que a desinfecção ocorresse. Todos os ensaios realizados alcançaram mais de 90% de eficiência na remoção de cor verdadeira em 96h de ensaio e mais de 92% de eficiência na eliminação de coliformes termotolerantes em 24h. / Degradation of grounded waste in landfill generates a liquid with high pollution potential characterized by its dark color, high concentration of organic matter and ammonia nitrogen. Landfill leachate may still contain pathogenic microorganisms from wastes contaminated by human excreta, presenting health risk. For treating landfill leachate, biological processes have shown good performance, especially in organic matter removal. However, in order for the removal efficiency to attain local legislation, particularly in older leachate, a post treatment is necessary. Use of advanced oxidation processes has shown efficiency in color removal, destruction of pathogens and increased biodegradability of recalcitrant effluents. The purpose of this study is to evaluate color removal and disinfection of landfill leachate using ozone and hydrogen peroxide as oxidizing agents. Therefore, twelve experiments were performed in AOP system treating raw and treated leachate by pond system. Six tests were conducted with ozone only and six combining ozone and hydrogen peroxide. The POA was operated with volume of 460L and tests were carried out for 96h. The ozone (gas) concentration was 29 mg/L and hydrogen peroxide (liquid solution added) was 1000 mg/L in the leachate. Characterization of landfill leachate generated in São Leopoldo showed high variability. Therefore, to discuss results of color removal, groups of tests were created using like criteria true color concentration. Although attained results indicated similarity between tested oxidants, performed ANOVA two factors with repeated measures showed difference between oxidizing agents used in color removal. Hydrogen peroxide outperformed ozone alone. True color removal occured faster with smaller true color concentrations. The disinfection of the leachate, using ozone combined with hydrogen peroxide showed higher inactivation rates of fecal coliforms. Turbidity and organic matter in the leachate did not prevent the disinfection. All tests reached over 90% efficiency in true color removal at 96h and over 92% efficiency in disinfection within 24h.

Page generated in 0.0586 seconds