An evaluation of patient-specific IMRT verification failures

Crawford, Jason 10 September 2010 (has links)
At the BC Cancer Agency (BCCA), Vancouver Island Centre (VIC), the clinical verification of Intensity Modulated Radiation Therapy (IMRT) treatment plans involves comparing Portal Image (PI) -based three-dimensionally reconstructed (EPIDose) dose distributions to planned doses calculated using the Pencil Beam Convolution (PBC) algorithm. Discrepancies surpassing established action levels constitute failure. Since 2007, the failure rate of IMRT verification process had been increasing, reaching as high as 18.5% in 2009. A retrospective evaluation of clinical IMRT verification failures was conducted to identify causes and possible resolutions. Thirty clinical verification failures were identified. An equipment malfunction was discovered and subsequently repaired, and several failures were resolved in the process. Statistical uncertainty in measurement outcome was small in comparison to action levels and not considered significant to the production of failures. Still, over 50% of the redelivered plans were shown to consistently fail. A subgroup of consistent verification plans were compared to ion chamber point dose measurements. Relative to ion chamber measurements, EPIDose underestimated the dose while the dose calculation algorithm (PBC, Eclipse version 8.1.18) overestimated the same point dose. Comparisons of individual fields demonstrated that none were identifiably problematic; dose discrepancies were the result of minor but accumulating dose differences. Consistent verification failures were recalculated using two advanced dose calculation engines (the Anisotropic Analytical Algorithm and Monte Carlo). In general, verification metrics improved, and all failures were resolved. Three distinct indices of fluence modulation (or complexity) were shown to correlate with verification metrics. This indicated that deficiencies in both the leaf motion calculator and the PBC (Eclipse version 8.1.18) had likely contributed to the production of failures. In conclusion, clinical verification failures were resolved retrospectively by replacing faulty equipment and using more advanced methods of planned dose calculation, supporting the efficacy and continued use of PI-based three dimensional dose reconstruction for IMRT verification.
362

Application radio-oncologique d'un plasma jet, l’APGD-t, pour le traitement de cancer du sein

Mahfoudh, Ahlem 08 1900 (has links)
No description available.
363

Étude Monte Carlo de l’impact de la tomodensitométrie multiénergie sur la précision du calcul de dose en protonthérapie

Lalonde, Arthur 02 1900 (has links)
No description available.
364

Méthodes de génération et de validation de champs de déformation pour la recombinaison de distribution de dose à l’aide d’images 4DCT dans le cadre d’une planification de traitement de cancers pulmonaires

Labine, Alexandre 12 1900 (has links)
Des efforts de recherche considérables ont été déployés afin d'améliorer les résultats de traitement de cancers pulmonaires. L'étude de la déformation de l'anatomie du patient causée par la ventilation pulmonaire est au coeur du processus de planification de traitement radio-oncologique. À l'aide d'images de tomodensitométrie quadridimensionnelles (4DCT), une simulation dosimétrique peut être calculée sur les 10 ensembles d'images du 4DCT. Une méthode doit être employée afin de recombiner la dose de radiation calculée sur les 10 anatomies représentant une phase du cycle respiratoire. L'utilisation de recalage déformable d'images (DIR), une méthode de traitement d'images numériques, génère neuf champs vectoriels de déformation permettant de rapporter neuf ensembles d'images sur un ensemble de référence correspondant habituellement à la phase d'expiration profonde du cycle respiratoire. L'objectif de ce projet est d'établir une méthode de génération de champs de déformation à l'aide de la DIR conjointement à une méthode de validation de leur précision. Pour y parvenir, une méthode de segmentation automatique basée sur la déformation surfacique de surface à été créée. Cet algorithme permet d'obtenir un champ de déformation surfacique qui décrit le mouvement de l'enveloppe pulmonaire. Une interpolation volumétrique est ensuite appliquée dans le volume pulmonaire afin d'approximer la déformation interne des poumons. Finalement, une représentation en graphe de la vascularisation interne du poumon a été développée afin de permettre la validation du champ de déformation. Chez 15 patients, une erreur de recouvrement volumique de 7.6 ± 2.5[%] / 6.8 ± 2.1[%] et une différence relative des volumes de 6.8 ± 2.4 [%] / 5.9 ± 1.9 [%] ont été calculées pour le poumon gauche et droit respectivement. Une distance symétrique moyenne 0.8 ± 0.2 [mm] / 0.8 ± 0.2 [mm], une distance symétrique moyenne quadratique de 1.2 ± 0.2 [mm] / 1.3 ± 0.3 [mm] et une distance symétrique maximale 7.7 ± 2.4 [mm] / 10.2 ± 5.2 [mm] ont aussi été calculées pour le poumon gauche et droit respectivement. Finalement, 320 ± 51 bifurcations ont été détectées dans le poumons droit d'un patient, soit 92 ± 10 et 228 ± 45 bifurcations dans la portion supérieure et inférieure respectivement. Nous avons été en mesure d'obtenir des champs de déformation nécessaires pour la recombinaison de dose lors de la planification de traitement radio-oncologique à l'aide de la méthode de déformation hiérarchique des surfaces. Nous avons été en mesure de détecter les bifurcations de la vascularisation pour la validation de ces champs de déformation. / Purpose: To allow a reliable deformable image registration (DIR) method for dose calculation in radiation therapy and to investigate an automatic vessel bifurcations detection algorithm for DIR assessment to improve lung cancer radiation treatment. Methods: 15 4DCT datasets are acquired and deep exhale respiratory phases are exported to Varian treatment planning system (TPS) Eclipse^{\text{TM}} for contouring. Voxelized contours are smoothed by a Gaussian filter and then transformed into a surface mesh representation. Such mesh is adapted by rigid and elastic deformations based on hierarchical surface deformation to match each subsequent lung volumes. The segmentation efficiency is assessed by comparing the segmented lung contour and the TPS contour considering two volume metrics, defined as Volumetric Overlap Error (VOE) [%] and Relative Volume Difference (RVD) [%] and three surface metrics, defined as Average Symmetric Surface Distance (ASSD) [mm], Root Mean Square Symmetric Surface Distance (RMSSD) [mm] and Maximum Symmetric Surface Distance (MSSD) [mm]. Vesselness filter was applied within the segmented lung volumes to identify blood vessels and airways. Segmented blood vessels and airways were skeletonised using a hierarchical curve-skeleton algorithm based on a generalized potential field approach. A graph representation of the computed skeleton was generated to assign one of three labels to each node: the termination node, the continuation node or the branching node. Results: The volume metrics obtained are a VOE of 7.6 ± 2.5[%] / 6.8 ± 2.1[%] and a RVD of 6.8 ± 2.4 [%] / 5.9 ± 1.9 [%] respectively for left and right lung. The surface metrics computed are an ASSD of 0.8 ± 0.2 [mm] / 0.8 ± 0.2 [mm], a RMSSD of 1.2 ± 0.2 [mm] / 1.3 ± 0.3 [mm] and a MSSD of 7.7 ± 2.4 [mm] / 10.2 ± 5.2 [mm] respectively for left and right lung. 320 ± 51 bifurcations were detected in the right lung of a patient for the 10 breathing phases. 92 ± 10 bifurcations were found in the upper half of the lung and 228 ± 45 bifurcations were found in the lower half of the lung. Discrepancies between ten vessel trees were mainly ascribed to the segmentation methode. Conclusions: This study shows that the morphological segmentation algorithm can provide an automatic method to capture an organ motion from 4DCT scans and translate it into a volume deformation grid needed by DIR method for dose distribution combination. We also established an automatic method for DIR assessment using the morphological information of the patient anatomy. This approach allows a description of the lung’s internal structure movement, which is needed to validate the DIR deformation fields.
365

Développement d'un nouveau critère pour déterminer les limites d'utilisation des détecteurs en dosimétrie non standard

Kamio, Yuji 12 1900 (has links)
Depuis quelques années, il y a un intérêt de la communauté en dosimétrie d'actualiser les protocoles de dosimétrie des faisceaux larges tels que le TG-51 (AAPM) et le TRS-398 (IAEA) aux champs non standard qui requièrent un facteur de correction additionnel. Or, ces facteurs de correction sont difficiles à déterminer précisément dans un temps acceptable. Pour les petits champs, ces facteurs augmentent rapidement avec la taille de champ tandis que pour les champs d'IMRT, les incertitudes de positionnement du détecteur rendent une correction cas par cas impraticable. Dans cette étude, un critère théorique basé sur la fonction de réponse dosimétrique des détecteurs est développé pour déterminer dans quelles situations les dosimètres peuvent être utilisés sans correction. Les réponses de quatre chambres à ionisation, d'une chambre liquide, d'un détecteur au diamant, d'une diode, d'un détecteur à l'alanine et d'un détecteur à scintillation sont caractérisées à 6 MV et 25 MV. Plusieurs stratégies sont également suggérées pour diminuer/éliminer les facteurs de correction telles que de rapporter la dose absorbée à un volume et de modifier les matériaux non sensibles du détecteur pour pallier l'effet de densité massique. Une nouvelle méthode de compensation de la densité basée sur une fonction de perturbation est présentée. Finalement, les résultats démontrent que le détecteur à scintillation peut mesurer les champs non standard utilisés en clinique avec une correction inférieure à 1%. / In recent years, the radiation dosimetry community has shown a keen interest in extending broad beam dosimetry protocols such as AAPM's TG-51 and IAEA's TRS-398 to nonstandard fields which involve the use of an additional correction factor. Yet, these correction factors are difficult to determine precisely in a time frame that is acceptable. For small fields, these factors increase rapidly with field size, whereas for composite IMRT fields, detector positioning uncertainties render a case-by-case correction impractical. In this study, a theoretical criterion based on radiation detectors' dose response functions is used to determine in which situations a given dosimeter can be used without correction. The responses of four ionization chambers, a liquid-filled chamber, a diamond detector, an unshieded diode, an alanine dosimeter and a plastic scintillator detector are characterized at 6 MV and 25 MV. Several strategies are also suggested to reduce/eliminate correction factors such as reporting the absorbed dose to a volume and modifying the non-sensitive components of a detector to compensate for mass density effects. A new method of density compensation based on a perturbation function is presented. Finally, results show that the scintillator detector can measure nonstandard fields used in the clinic with corrections under 1%.
366

Développement d'un nouveau critère pour déterminer les limites d'utilisation des détecteurs en dosimétrie non standard

Kamio, Yuji 12 1900 (has links)
Depuis quelques années, il y a un intérêt de la communauté en dosimétrie d'actualiser les protocoles de dosimétrie des faisceaux larges tels que le TG-51 (AAPM) et le TRS-398 (IAEA) aux champs non standard qui requièrent un facteur de correction additionnel. Or, ces facteurs de correction sont difficiles à déterminer précisément dans un temps acceptable. Pour les petits champs, ces facteurs augmentent rapidement avec la taille de champ tandis que pour les champs d'IMRT, les incertitudes de positionnement du détecteur rendent une correction cas par cas impraticable. Dans cette étude, un critère théorique basé sur la fonction de réponse dosimétrique des détecteurs est développé pour déterminer dans quelles situations les dosimètres peuvent être utilisés sans correction. Les réponses de quatre chambres à ionisation, d'une chambre liquide, d'un détecteur au diamant, d'une diode, d'un détecteur à l'alanine et d'un détecteur à scintillation sont caractérisées à 6 MV et 25 MV. Plusieurs stratégies sont également suggérées pour diminuer/éliminer les facteurs de correction telles que de rapporter la dose absorbée à un volume et de modifier les matériaux non sensibles du détecteur pour pallier l'effet de densité massique. Une nouvelle méthode de compensation de la densité basée sur une fonction de perturbation est présentée. Finalement, les résultats démontrent que le détecteur à scintillation peut mesurer les champs non standard utilisés en clinique avec une correction inférieure à 1%. / In recent years, the radiation dosimetry community has shown a keen interest in extending broad beam dosimetry protocols such as AAPM's TG-51 and IAEA's TRS-398 to nonstandard fields which involve the use of an additional correction factor. Yet, these correction factors are difficult to determine precisely in a time frame that is acceptable. For small fields, these factors increase rapidly with field size, whereas for composite IMRT fields, detector positioning uncertainties render a case-by-case correction impractical. In this study, a theoretical criterion based on radiation detectors' dose response functions is used to determine in which situations a given dosimeter can be used without correction. The responses of four ionization chambers, a liquid-filled chamber, a diamond detector, an unshieded diode, an alanine dosimeter and a plastic scintillator detector are characterized at 6 MV and 25 MV. Several strategies are also suggested to reduce/eliminate correction factors such as reporting the absorbed dose to a volume and modifying the non-sensitive components of a detector to compensate for mass density effects. A new method of density compensation based on a perturbation function is presented. Finally, results show that the scintillator detector can measure nonstandard fields used in the clinic with corrections under 1%.
367

Nuclear reactions with 11C and 14O radioactive ion beams

Guo, Fanqing January 2004 (has links)
Thesis (Ph.D.); Submitted to the UNIVERSITY OF CALIFORNIA, BERKELEY, CA (US); 9 Dec 2004. / Published through the Information Bridge: DOE Scientific and Technical Information. "LBNL--56744" Guo, Fanqing. USDOE Director. Office of Science. Office of Nuclear Physics (US) 12/09/2004. Report is also available in paper and microfiche from NTIS.
368

Étude de la tomodensitométrie spectrale quantitative et ses applications en radiothérapie

Simard, Mikaël 02 1900 (has links)
La tomodensitométrie par rayons-X (CT) est une modalité d’imagerie produisant une carte tridimensionnelle du coefficient d’atténuation des rayons-X d’un objet. En radiothérapie, le CT fournit de l’information anatomique et quantitative sur le patient afin de permettre la planification du traitement et le calcul de la dose de radiation à livrer. Le CT a plusieurs problèmes, notamment (1) une limitation au niveau de l’exactitude des paramètres physiques quantitatifs extraits du patient, et (2) une sensibilité aux biais causés par des artéfacts de durcissement du faisceau. Enfin, (3) dans le cas où le CT est fait en présence d’un agent de contraste pour améliorer la planification du traitement, il est nécessaire d’effectuer un deuxième CT sans agent de contraste à des fins de calcul de dose, ce qui augmente la dose au patient. Ces trois problèmes limitent l’efficacité du CT pour certaines modalités de traitement qui sont plus sensibles aux incertitudes comme la protonthérapie. Le CT spectral regroupe un ensemble de méthodes pour produire plusieurs cartes d’atténuation des rayons-X moyennées sur différentes plages énergétiques. L’information supplémentaire, pondérée en énergie qui est obtenue permet une meilleure caractérisation des matériaux analysés. Le potentiel de l’une de ces modalités spectrales, le CT bi-énergie (DECT), est déjà bien démontré en radiothérapie, alors qu’une approche en plein essor, le CT spectral à comptage de photons (SPCCT), promet davantage d’information spectrale à l’aide de détecteurs discriminateurs en énergie. Par contre, le SPCCT souffre d’un bruit plus important et d’un conditionnement réduit. Cette thèse investigue la question suivante : y a-t-il un bénéfice à utiliser plus d’information résolue en énergie, mais de qualité réduite pour la radiothérapie ? La question est étudiée dans le contexte des trois problèmes ci-haut. Tout d’abord, un estimateur maximum a posteriori (MAP) est introduit au niveau de la caractérisation des tissus post-reconstruction afin de débruiter les données du CT spectral. L’approche est validée expérimentalement sur un DECT. Le niveau de bruit du pouvoir d’arrêt des protons diminue en moyenne d’un facteur 3.2 à l’aide de l’estimateur MAP. Celui-ci permet également de conserver généralement le caractère quantitatif des paramètres physiques estimés, le pouvoir d’arrêt variant en moyenne de 0.9% par rapport à l’approche conventionnelle. Ensuite, l’estimateur MAP est adapté au contexte de l’imagerie avec agent de contraste. Les résultats numériques démontrent un bénéfice clair à utiliser le SPCCT pour l’imagerie virtuellement sans contraste par rapport au DECT, avec une réduction de l’erreur RMS sur le pouvoir d’arrêt des protons de 2.7 à 1.4%. Troisièmement, les outils développés ci-haut sont validés expérimentalement sur un micro-SPCCT de la compagnie MARS Bioimaging, dont le détecteur à comptage de photons est le Medipix 3, qui est utilisé pour le suivi de particules au CERN. De légers bénéfices au niveau de l’estimation des propriétés physiques à l’aide du SPCCT par rapport au DECT sont obtenus pour des matériaux substituts à des tissus humains. Finalement, une nouvelle paramétrisation du coefficient d’atténuation pour l’imagerie pré-reconstruction est proposée, dans le but ultime de corriger les artéfacts de durcissement du faisceau. La paramétrisation proposée élimine les biais au niveau de l’exactitude de la caractérisation des tissus humains par rapport aux paramétrisations existantes. Cependant, aucun avantage n’a été obtenu à l’aide du SPCCT par rapport au DECT, ce qui suggère qu’il est nécessaire d’incorporer l’estimation MAP dans l’imagerie pré-reconstruction via une approche de reconstruction itérative. / X-ray computed tomography (CT) is an imaging modality that produces a tridimensional map of the attenuation of X-rays by the scanned object. In radiation therapy, CT provides anatomical and quantitative information on the patient that is required for treatment planning. However, CT has some issues, notably (1) a limited accuracy in the estimation of quantitative physical parameters of the patient, and (2) a sensitivity to biases caused by beam hardening artifacts. Finally, (3) in the case where contrast-enhanced CT is performed to help treatment planning, a second scan with no contrast agent is required for dose calculation purposes, which increases the overall dose to the patient. Those 3 problems limit the efficiency of CT for some treatment modalities more sensitive to uncertainties, such as proton therapy. Spectral CT regroups a set of methods that allows the production of multiple X-ray attenuation maps evaluated over various energy windows. The additional energy-weighted information that is obtained allows better material characterization. The potential of one spectral CT modality, dual-energy CT (DECT), is already well demonstrated for radiation therapy, while an upcoming method, spectral photon counting CT (SPCCT), promises more spectral information with the help of energy discriminating detectors. Unfortunately, SPCCT suffers from increased noise and poor conditioning. This thesis thus investigates the following question: is there a benefit to using more, but lower quality energy-resolved information for radiotherapy? The question is studied in the context of the three problems discussed earlier. First, a maximum a posteriori (MAP) estimator is introduced for post-reconstruction tissue characterization for denoising purposes in spectral CT. The estimator is validated experimentally using a commercial DECT. The noise level on the proton stopping power is reduced, on average, by a factor of 3.2 with the MAP estimator. The estimator also generally con- serves the quantitative accuracy of estimated physical parameters. For instance, the stopping power varies on average by 0.9% with respect to the conventional approach. Then, the MAP estimation framework is adapted to the context of contrast-enhanced imaging. Numerical results show clear benefits when using SPCCT for virtual non-contrast imaging compared to DECT, with a reduction of the RMS error on the proton stopping power from 2.7 to 1.4%. Third, the developed tools are validated experimentally on a micro-SPCCT from MARS Bioimaging, which uses the Medipix 3 chip as a photon counting detector. Small benefits in the accuracy of physical parameters of tissue substitutes materials are obtained. Finally, a new parametrization of the attenuation coefficient for pre-reconstruction imaging is pro- posed, whose ultimate aim is to correct beam hardening artifacts. In a simulation study, the proposed parametrization eliminates all biases in the estimated physical parameters of human tissues, which is an improvement upon existing parametrizations. However, no ad- vantage has been obtained with SPCCT compared to DECT, which suggests the need to incorporate MAP estimation in the pre-reconstruction framework using an iterative reconstruction approach.
369

Detector dose response to megavoltage photon beams coupled to magnetic fields

Cervantes Espinosa, Yunuen 08 1900 (has links)
La radiothérapie guidée par résonance magnétique promet une administration de dose plus précise que les techniques conventionnelles puisqu’elle permet une visualisation en temps réel des structures internes avant et pendant le traitement. Cependant, la dosimétrie doit être réalisée en présence de champs magnétiques. Alors que le champ magnétique n’affecte pas le transport des particules neutres, il affecte le transport des particules chargées secondaires en raison de la force de Lorentz, qui modifie le champ de rayonnement et la réponse de dose du détecteur. Cette thèse vise à comprendre l’effet du champ magnétique sur la réponse de dose du détecteur, à la caractériser et à fournir des facteurs de correction de qualité prenant en compte l’impact du champ magnétique. Dans le premier article, quatre chambres d’ionisation à petite cavité ont été caractérisées via des simulations de Monte Carlo et des mesures expérimentales. Il a été constaté que le champ magnétique accentuait tous les détails géométriques. Une description précise du volume sensible effectif est cruciale dans les simulations. De plus, la géométrie modélisée doit être aussi proche que possible de la géométrie réelle, y compris les couches d’air internes. Des facteurs de correction de qualité tenant compte du champ magnétique et de son incertitude du budget d’incertitude sont présentés pour différentes configurations. Le deuxième article a évalué l’effet du champ magnétique sur les facteurs de perturbation de cinq détecteurs à petite cavité, dont trois détecteurs à petite cavité et deux détecteurs à semi-conducteurs. Les facteurs de perturbation des composants structurels, les facteurs de moyenne de densité et de volume ont été déterminés pour différentes tailles de champ et orientations. De plus, des facteurs de correction de qualité ont été calculés dans les mêmes conditions. Les résultats montrent que le champ magnétique a un impact significatif sur le facteur de perturbation de la densité dans les chambres d’ionisation. En revanche, son impact est plus prononcé dans les composants structurels des détecteurs semi-conducteurs. L’objectif du troisième article était de fournir plus d’informations sur la compréhension de la relation dose-réponse des détecteurs dans les champs magnétiques via des calculs de spectres de fluence électronique. La fluence des électrons différentiel en énergie dans la cavité du détecteur peut être fortement modifiée dans les champs magnétiques, et les perturbations de fluence sont généralement plus évidentes pour les électrons de faible énergie. Ces calculs ont montré l’interaction entre plusieurs facteurs qui rendent les effets de perturbation imprévisibles dans le faisceau de photons couplé aux champs magnétiques : 1) orientation du détecteur et du champ magnétique, 2) taille et forme de la cavité, 3) composants structurels, 4) couche d’air entre le détecteur et le milieu et leur asymétrie, et 5) l’énergie. / Magnetic resonance-guided radiation therapy promises more accurate dose delivery than conventional techniques by allowing real-time visualization of internal structures before and during treatment. However, the dosimetry must be performed in the presence of magnetic fields. While the magnetic field does not affect the transport of uncharged particles, it affects the transport of secondary charged particles due to the Lorentz force, which modifies the radiation field and the detector dose-response. This thesis aims to understand the effect of the magnetic field on detector dose-response, characterize it, and provide quality correction factors accounting for the impact of the magnetic field. In the first article, four small-cavity ionization chambers were characterized via Monte Carlo simulations and experimental measurements. It was found that the magnetic field emphasized all the geometrical details. An accurate description of the effective sensitive volume is crucial in the simulations. Also, the modelled geometry must be as close as possible to the actual geometry, including the internal air layers. Quality correction factors accounting for the magnetic field and its uncertainty budget uncertainty are presented for different configurations. The second article evaluated the magnetic field effect on perturbation factors of five small volume detectors, including three ionization chambers and two solid-state detectors. The perturbation factors from extracameral components, density and volume averaging factors were determined for different field sizes and orientation setups. Additionally, quality correction factors were calculated in the same conditions. Results show that the magnetic field significantly impacts the density perturbation factor in the ionization chambers. In contrast, its impact is more pronounced in the extracameral components in the solid-state detectors. The purpose of the third article was to provide more insight into the understanding of detector dose-response in magnetic fields via calculations of electron fluence spectra. The electron fluence differential in energy in the detector cavity can be severely modified in magnetic fields, and fluence perturbations are generally more evident for low-energy electrons. These calculations showed the interplay between multiple factors that make the perturbation effects unpredictable in photon beams coupled to magnetic fields: 1) detector and magnetic field orientation, 2) cavity size and shape, 3) extracameral components, 4) air gaps and their asymmetry, and 5) energy.