• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • Tagged with
  • 7
  • 7
  • 5
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Influência do método de osteotomia para preparação do leito na reparação óssea ao redor de implantes de titânio: comparação histológica entre instrumento rotatório e ultrassom cirúrgico piezoelétrico / Piezosurgery influence in bone healing around titanium dental implants: histological study in rats

Ferreira, Marcelo Sirolli 19 February 2014 (has links)
O objetivo deste estudo foi avaliar histomorfometricamente a influência da piezocirurgia (PZ) sobre a reparação óssea ao redor de implantes de titânio. Foram utilizados 15 ratos machos Wistar, com aproximadamente 300g, nos quais em uma das patas o leito para instalação de um implante de titânio foi realizado com um motor rotatório convencional (Grupo Controle) e na outra com ultrassom cirúrgico piezoelétrico (Grupo Piezo). Após 30 dias, os animais foram sacrificados para obtenção do material para análise histológica. Foram avaliados os seguintes parâmetros histomorfométricos (em porcentagem), separadamente, para a região cortical e medular: a proporção de tecido mineralizado (PTM) na região adjacente ao implante (500m adjacentes); área de tecido mineralizado (AO) dentro dos limites das roscas do implante; e a extensão de tecido ósseo em contato direto (CD) com a superfície do implante. Os resultados deste estudo mostraram que não foram observadas diferenças para CD na região medular (p>0,05) e para PTM na região cortical (p>0,05). Por outro lado, um maior preenchimento das roscas foi observado quando utilizou-se a PZ tanto na região cortical (71,50 + 6,91 e 78,28 + 4,38; média + dp para os grupos Controle e Piezo; respectivamente p<0,05) quanto na região medular (9,62 + 4,06 e 19,94 + 14,18; média + dp para os grupos Controle e Piezo; respectivamente p<0,05). Resultados semelhantes foram observados para o parâmetro PTM na região medular (9,35 + 5,54 e 18,72 + 13,21; média + dp para os grupos Controle e Piezo; respectivamente p<0,05). Já a técnica convencional foi superior à PZ em relação a CD na região cortical (80,42 + 10,88 e 70,25 + 16,93; média + dp para os grupos Controle e Piezo; respectivamente p<0,05). Dentro dos limites do presente estudo, pode-se concluir que a piezocirurgia apresenta-se como uma alternativa viável no preparo de leito para instalação de implantes de titânio. / The aim of this study was to investigate the influence of two techniques of dental implant site preparation on bone healing around titanium dental implants. Fifteen male Wistar rats (+ 300g) were used in the study. In each rat tibiae was randomly assigned to receive the implant site preparation with a conventional drilling technique (Control) or with piezoelectric device (Piezo). After thirty days the animals were sacrificed and then the following histomorphometric parameters were evaluated (in percentage) separately to cortical and cancellous regions: Proportion of mineralized tissue (PMT) adjacent to implant threads (500um adjacent); bone area within the threads (BA); and bone-implant contact (BIC). The results demonstrated that there were no differences between the two groups for cancellous BIC (p>0.05) and cortical PTM (p>0.05). Meanwhile, a higher percentage of BA was observed in PIEZO group in the cortical (71,50 + 6,91 and 78,28 + 4,38; mean + stdev for groups Control and Piezo; respectively p<0.05) and cancellous regions (9,62 + 4,06 and 19,94 + 14,18; mean + stdev for groups Control and Piezo; respectively p<0.05). The piezosurgery also showed higher PTM values in the cancellous zone (9,35 + 5,54 and 18,72 + 13,21; mean + stdev for groups Control and Piezo; respectively p<0.05). However, Control presented better results for BIC in cortical region (80,42 + 10,88 and 70,25 + 16,93; mean + stdev for groups CTRL and PIEZO; respectively p<0.05). Within the limits of the present study, it can be concluded that piezosurgery is a feasible alternative in implant site preparation.
2

Espondilectomia parcial ventral cervical com osteotomia piezoelétrica e convencional em coelhos (Oryctolagus cuniculus) /

Roscamp, Marcelo January 2017 (has links)
Orientador: Luis Gustavo Gosuen Gonçalves Dias / Banca: Silvio Henrique de Freitas / Banca: Fabricio Singaretti de Oliveira / Resumo: A cirurgia piezoelétrica ou piezocirurgia é utilizada há várias décadas, porém em medicina veterinária são escassos os artigos publicados utilizando esta modalidade em cirurgias descompressivas da coluna vertebral de cães e gatos. Assim, aventou-se com esse trabalho investigar a aplicabilidade da mesma na realização da espondilectomia parcial ventral cervical (EPVC), comparando-a com a técnica convencional que utiliza brocas esféricas de alta rotação para o desgaste ósseo, utilizando o coelho (Oryctolagus cuniculus) como modelo experimental de cães e gatos. Para tanto foi utilizado o aparelho médico Mastersonic®, que possui duas peças de mão, uma piezoelétrica com ponteira ultrassônica tipo cinzel delicado (T1) e na outra, motor de alta rotação com brocas esférica de 2 mm (técnica convencional) (T2). A EPVC foi realizada entre a terceira e quarta vértebras cervicais e cada técnica foi realizada em 15 animais, devidamente anestesiados, os quais foram avaliados quanto à duração de cada etapa da cirurgia, variações de temperatura durante a execução da EPVC, visibilidade do campo cirúrgico, complicações trans e pós-operatórias e monitoração anestésica. Aos 14, 28 e 56 dias de pós-operatório (PO), cinco animais de cada tratamento foram submetidos à eutanásia e realizado estudo histopatológico do local da cirurgia, avaliando à resposta inflamatória, à cicatrização óssea e as lesões medulares. Os resultados mostraram que T1 demandou mais tempo para a execução da curetagem e maior pe... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Piezoelectric surgery or piezosurgery has been used for several decades, but in veterinary medicine, articles published using this modality in decompressive surgery of the spine of dogs and cats are scarce. The aim of this study was to investigate the applicability of this technique to the performance of cervical ventral partial spondylectomy (CVPS), comparing it with the conventional technique using high-rotation spherical drills for bone wear using rabbit (Oryctolagus cuniculus) as an experimental model of dogs and cats.. For this was used Mastersonic® medical device that has two hand pieces, one piezoelectric type with ultrasonic delicate chisel tip (T1) and the other, high speed engine with spherical drills 2 mm (conventional technique) (T2). The CVPS was held between the third and fourth cervical vertebrae and each technique was performed on 15 animals, under anesthesia, which were evaluated for the duration of each stage of surgery, temperature variations during the execution of CVPS, the surgical field visibility, trans and postoperative complications and anesthetic monitoring. At 14, 28 and 56 postoperative days (PO), five animals per treatment were euthanized, and histological studies were carried to the surgical site by assessing the inflammatory response, and bone healing spinal injuries. The results showed that T1 required more time for curettage execution and highest loss of temperature at the surgical focus during surgery. Surgical access time progressively redu... (Complete abstract click electronic access below) / Mestre
3

Avaliação da estabilidade primária de implantes instalados em cavidades confeccionadas por meio do ultrassom cirúrgico e instrumentos rotatórios convencionais: Estudo in Vitro / Assessment of the primary stability of dental implants prepared cavities with piezosurgery and conventional rotatory instruments: In Vitro study

Silva, Leonardo de Freitas [UNESP] 17 October 2016 (has links)
Submitted by LEONARDO DE FREITAS SILVA null (leonardofreitas86@gmail.com) on 2016-10-20T13:26:49Z No. of bitstreams: 1 Dissertação de mestrado- reapresentação 1.pdf: 1472109 bytes, checksum: e157f95a9ba34bce0469c51f091af276 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-10-26T17:52:37Z (GMT) No. of bitstreams: 1 silva_lf_me_arafo.pdf: 1472109 bytes, checksum: e157f95a9ba34bce0469c51f091af276 (MD5) / Made available in DSpace on 2016-10-26T17:52:37Z (GMT). No. of bitstreams: 1 silva_lf_me_arafo.pdf: 1472109 bytes, checksum: e157f95a9ba34bce0469c51f091af276 (MD5) Previous issue date: 2016-10-17 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A estabilidade primária de implantes dentários corresponde a um fenômeno mecânico relativo à qualidade ou quantidade óssea, ao tipo de implante e a técnica de instalação. O objetivo deste trabalho foi avaliar o tempo de fresagem, aquecimento dos sítios fresados e a estabilidade dos implantes instalados em cavidades realizadas com ultrassom cirúrgico e instrumentos rotatórios. Foram realizadas 64 cavidades em 04 blocos de poliuretano simulando as densidades de ossos tipo I, II, III e IV. A temperatura da superfície do bloco nos leitos foi medida durante a fresagem. A estabilidade dos implantes foi mensurada por meio do torque de inserção, de remoção e frequência de ressonância. O implante cilíndrico TitaOss 3,75 x 11 mm foi instalado em todas as cavidades. Os resultados mostraram maior tempo e temperatura para o grupo em que foi usado o ultrassom. Quanto à estabilidade primária não houve diferença significante entre os grupos estudados. Pôde-se concluir que a estabilidade primária dos implantes não foi influenciada pelos métodos de fresagem utilizados e que o ultrassom cirúrgico necessitou de mais tempo e gerou mais calor do que o instrumento rotatório para o preparo das cavidades. / The primary stability of dental implants corresponds to a mechanical phenomenon related to bone quality or quantity, type of implant and installation technique. The objective of this study was to evaluate the time of drilling, heating drilled sites and stability of implants placed in cavities made with piezosurgery and rotary instruments. Polyurethane blocks were used simulating the densities of bone type I, II, III and IV. The surface temperature of the block was measured in the cavity during drilling, and recorded the highest temperature variation. The stability of the implants was measured with a torque insertion, torque of removal and resonance frequency. The cylindrical implant TitaOss 3.75 x 11 mm was used in all cavities. The results showed greater time and temperature for the group that was used piezosurgery. The primary stability was no significant difference between groups. It could be concluded that implant primary stability was not influenced by the used methods and piezosurgery took more time and generated more heat than the conventional rotatory instruments to prepare the cavities.
4

Avaliação da estabilidade primária de implantes instalados em cavidades confeccionadas por meio do ultrassom cirúrgico e instrumentos rotatórios convencionais : estudo in vitro /

Silva, Leonardo de Freitas. January 2016 (has links)
Orientador: Idelmo Rangel Garcia Júnior / Coorientador: Daniela Ponzoni / Banca: Francisley Ávila Souza / Banca: Abrahão Cavalcante Gomes de Souza Carvalho / Resumo: A estabilidade primária de implantes dentários corresponde a um fenômeno mecânico relativo à qualidade ou quantidade óssea, ao tipo de implante e a técnica de instalação. O objetivo deste trabalho foi avaliar o tempo de fresagem, aquecimento dos sítios fresados e a estabilidade dos implantes instalados em cavidades realizadas com ultrassom cirúrgico e instrumentos rotatórios. Foram realizadas 64 cavidades em 04 blocos de poliuretano simulando as densidades de ossos tipo I, II, III e IV. A temperatura da superfície do bloco nos leitos foi medida durante a fresagem. A estabilidade dos implantes foi mensurada por meio do torque de inserção, de remoção e frequência de ressonância. O implante cilíndrico TitaOss 3,75 x 11 mm foi instalado em todas as cavidades. Os resultados mostraram maior tempo e temperatura para o grupo em que foi usado o ultrassom. Quanto à estabilidade primária não houve diferença significante entre os grupos estudados. Pôde-se concluir que a estabilidade primária dos implantes não foi influenciada pelos métodos de fresagem utilizados e que o ultrassom cirúrgico necessitou de mais tempo e gerou mais calor do que o instrumento rotatório para o preparo das cavidades. / The primary stability of dental implants corresponds to a mechanical phenomenon related to bone quality or quantity, type of implant and installation technique. The objective of this stud y was to evaluate the time of drilling, heating drilled sites and stability of implants placed in cavities made with piezosurgery and rotary instruments. Polyurethane blocks were used simulating the densities of bone type I, II, III and IV. The surface tem perature of the block was measured in the cavity during drilling, and recorded the highest temperature variation. The stability of the implants was measured with a torque insertion, torque of removal and resonance frequency. The cylindrical implant TitaOss 3.75 x 11 mm was used in all cavities. The results showed greater time and temperature for the group that was used piezosurgery. The primary stability was no significant difference between groups. It could be concluded that implant primary stability was n ot influenced by the used methods and piezosurgery took more time and generated more heat than the conventional rotatory instruments to prepare the cavities. / Mestre
5

Influência do método de osteotomia para preparação do leito na reparação óssea ao redor de implantes de titânio: comparação histológica entre instrumento rotatório e ultrassom cirúrgico piezoelétrico / Piezosurgery influence in bone healing around titanium dental implants: histological study in rats

Marcelo Sirolli Ferreira 19 February 2014 (has links)
O objetivo deste estudo foi avaliar histomorfometricamente a influência da piezocirurgia (PZ) sobre a reparação óssea ao redor de implantes de titânio. Foram utilizados 15 ratos machos Wistar, com aproximadamente 300g, nos quais em uma das patas o leito para instalação de um implante de titânio foi realizado com um motor rotatório convencional (Grupo Controle) e na outra com ultrassom cirúrgico piezoelétrico (Grupo Piezo). Após 30 dias, os animais foram sacrificados para obtenção do material para análise histológica. Foram avaliados os seguintes parâmetros histomorfométricos (em porcentagem), separadamente, para a região cortical e medular: a proporção de tecido mineralizado (PTM) na região adjacente ao implante (500m adjacentes); área de tecido mineralizado (AO) dentro dos limites das roscas do implante; e a extensão de tecido ósseo em contato direto (CD) com a superfície do implante. Os resultados deste estudo mostraram que não foram observadas diferenças para CD na região medular (p>0,05) e para PTM na região cortical (p>0,05). Por outro lado, um maior preenchimento das roscas foi observado quando utilizou-se a PZ tanto na região cortical (71,50 + 6,91 e 78,28 + 4,38; média + dp para os grupos Controle e Piezo; respectivamente p<0,05) quanto na região medular (9,62 + 4,06 e 19,94 + 14,18; média + dp para os grupos Controle e Piezo; respectivamente p<0,05). Resultados semelhantes foram observados para o parâmetro PTM na região medular (9,35 + 5,54 e 18,72 + 13,21; média + dp para os grupos Controle e Piezo; respectivamente p<0,05). Já a técnica convencional foi superior à PZ em relação a CD na região cortical (80,42 + 10,88 e 70,25 + 16,93; média + dp para os grupos Controle e Piezo; respectivamente p<0,05). Dentro dos limites do presente estudo, pode-se concluir que a piezocirurgia apresenta-se como uma alternativa viável no preparo de leito para instalação de implantes de titânio. / The aim of this study was to investigate the influence of two techniques of dental implant site preparation on bone healing around titanium dental implants. Fifteen male Wistar rats (+ 300g) were used in the study. In each rat tibiae was randomly assigned to receive the implant site preparation with a conventional drilling technique (Control) or with piezoelectric device (Piezo). After thirty days the animals were sacrificed and then the following histomorphometric parameters were evaluated (in percentage) separately to cortical and cancellous regions: Proportion of mineralized tissue (PMT) adjacent to implant threads (500um adjacent); bone area within the threads (BA); and bone-implant contact (BIC). The results demonstrated that there were no differences between the two groups for cancellous BIC (p>0.05) and cortical PTM (p>0.05). Meanwhile, a higher percentage of BA was observed in PIEZO group in the cortical (71,50 + 6,91 and 78,28 + 4,38; mean + stdev for groups Control and Piezo; respectively p<0.05) and cancellous regions (9,62 + 4,06 and 19,94 + 14,18; mean + stdev for groups Control and Piezo; respectively p<0.05). The piezosurgery also showed higher PTM values in the cancellous zone (9,35 + 5,54 and 18,72 + 13,21; mean + stdev for groups Control and Piezo; respectively p<0.05). However, Control presented better results for BIC in cortical region (80,42 + 10,88 and 70,25 + 16,93; mean + stdev for groups CTRL and PIEZO; respectively p<0.05). Within the limits of the present study, it can be concluded that piezosurgery is a feasible alternative in implant site preparation.
6

Espondilectomia parcial ventral cervical com osteotomia piezoelétrica e convencional em coelhos (Oryctolagus cuniculus) / Cervical ventral partial spondilectomy with piezoeletric and conventional osteotomy in rabbits (Oryctolagus cuniculus)

Roscamp, Marcelo 09 October 2017 (has links)
Submitted by Marcelo Roscamp (marcelo@ortopediapet.com) on 2017-11-16T13:57:30Z No. of bitstreams: 1 Dissertação_Marcelo_Roscamp.pdf: 9443012 bytes, checksum: 69bacbdda807a3e9fee0f785465385c3 (MD5) / Submitted by Marcelo Roscamp (marcelo@ortopediapet.com) on 2017-11-22T14:06:58Z No. of bitstreams: 1 Dissertação_Marcelo_Roscamp.pdf: 9443012 bytes, checksum: 69bacbdda807a3e9fee0f785465385c3 (MD5) / Submitted by Marcelo Roscamp (marcelo@ortopediapet.com) on 2017-11-22T18:09:13Z No. of bitstreams: 1 Dissertação_Marcelo_Roscamp.pdf: 9443012 bytes, checksum: 69bacbdda807a3e9fee0f785465385c3 (MD5) / Submitted by Marcelo Roscamp (marcelo@ortopediapet.com) on 2017-11-22T18:12:23Z No. of bitstreams: 1 Dissertação_Marcelo_Roscamp.pdf: 9443012 bytes, checksum: 69bacbdda807a3e9fee0f785465385c3 (MD5) / Submitted by Marcelo Roscamp (marcelo@ortopediapet.com) on 2017-11-22T19:44:21Z No. of bitstreams: 1 Dissertação_Marcelo_Roscamp.pdf: 9443012 bytes, checksum: 69bacbdda807a3e9fee0f785465385c3 (MD5) / Submitted by Marcelo Roscamp (marcelo@ortopediapet.com) on 2017-11-23T11:57:14Z No. of bitstreams: 1 Dissertação_Marcelo_Roscamp.pdf: 9443012 bytes, checksum: 69bacbdda807a3e9fee0f785465385c3 (MD5) / Submitted by Marcelo Roscamp (marcelo@ortopediapet.com) on 2017-11-23T12:57:56Z No. of bitstreams: 1 Dissertação_Marcelo_Roscamp.pdf: 9443012 bytes, checksum: 69bacbdda807a3e9fee0f785465385c3 (MD5) / Submitted by Marcelo Roscamp (marcelo@ortopediapet.com) on 2017-11-23T13:16:32Z No. of bitstreams: 1 Dissertação_Marcelo_Roscamp.pdf: 9443012 bytes, checksum: 69bacbdda807a3e9fee0f785465385c3 (MD5) / Submitted by Marcelo Roscamp (marcelo@ortopediapet.com) on 2017-11-23T13:34:44Z No. of bitstreams: 1 Dissertação_Marcelo_Roscamp.pdf: 9443012 bytes, checksum: 69bacbdda807a3e9fee0f785465385c3 (MD5) / Submitted by Marcelo Roscamp (marcelo@ortopediapet.com) on 2017-11-23T17:24:55Z No. of bitstreams: 1 Dissertação_Marcelo_Roscamp.pdf: 9443012 bytes, checksum: 69bacbdda807a3e9fee0f785465385c3 (MD5) / Submitted by Marcelo Roscamp (marcelo@ortopediapet.com) on 2017-11-23T17:29:02Z No. of bitstreams: 1 Dissertação_Marcelo_Roscamp.pdf: 9443012 bytes, checksum: 69bacbdda807a3e9fee0f785465385c3 (MD5) / Submitted by Marcelo Roscamp (marcelo@ortopediapet.com) on 2017-11-24T12:05:24Z No. of bitstreams: 1 Dissertação_Marcelo_Roscamp.pdf: 9443012 bytes, checksum: 69bacbdda807a3e9fee0f785465385c3 (MD5) / Submitted by Marcelo Roscamp (marcelo@ortopediapet.com) on 2017-11-24T12:39:44Z No. of bitstreams: 1 Dissertação_Marcelo_Roscamp.pdf: 9443012 bytes, checksum: 69bacbdda807a3e9fee0f785465385c3 (MD5) / Submitted by Marcelo Roscamp (marcelo@ortopediapet.com) on 2017-11-24T16:47:38Z No. of bitstreams: 1 Dissertação_Marcelo_Roscamp.pdf: 9443012 bytes, checksum: 69bacbdda807a3e9fee0f785465385c3 (MD5) / Submitted by Marcelo Roscamp (marcelo@ortopediapet.com) on 2017-11-24T17:31:22Z No. of bitstreams: 1 Dissertação_Marcelo_Roscamp.pdf: 9443012 bytes, checksum: 69bacbdda807a3e9fee0f785465385c3 (MD5) / Submitted by Marcelo Roscamp (marcelo@ortopediapet.com) on 2017-11-27T11:40:50Z No. of bitstreams: 1 Dissertação_Marcelo_Roscamp.pdf: 9443012 bytes, checksum: 69bacbdda807a3e9fee0f785465385c3 (MD5) / Submitted by Marcelo Roscamp (marcelo@ortopediapet.com) on 2017-11-27T12:31:51Z No. of bitstreams: 1 Dissertação_Marcelo_Roscamp.pdf: 9443012 bytes, checksum: 69bacbdda807a3e9fee0f785465385c3 (MD5) / Submitted by Marcelo Roscamp (marcelo@ortopediapet.com) on 2017-11-27T13:03:15Z No. of bitstreams: 1 Dissertação_Marcelo_Roscamp.pdf: 9443012 bytes, checksum: 69bacbdda807a3e9fee0f785465385c3 (MD5) / Submitted by Marcelo Roscamp (marcelo@ortopediapet.com) on 2017-11-27T18:08:07Z No. of bitstreams: 1 Dissertação_Marcelo_Roscamp.pdf: 9443012 bytes, checksum: 69bacbdda807a3e9fee0f785465385c3 (MD5) / Submitted by Marcelo Roscamp (marcelo@ortopediapet.com) on 2017-11-28T12:13:08Z No. of bitstreams: 1 Dissertação_Marcelo_Roscamp.pdf: 9443012 bytes, checksum: 69bacbdda807a3e9fee0f785465385c3 (MD5) / Submitted by Marcelo Roscamp (marcelo@ortopediapet.com) on 2017-11-28T14:22:46Z No. of bitstreams: 1 Dissertação_Marcelo_Roscamp.pdf: 9443012 bytes, checksum: 69bacbdda807a3e9fee0f785465385c3 (MD5) / Submitted by Marcelo Roscamp (marcelo@ortopediapet.com) on 2017-11-28T14:31:56Z No. of bitstreams: 1 Dissertação_Marcelo_Roscamp.pdf: 9443012 bytes, checksum: 69bacbdda807a3e9fee0f785465385c3 (MD5) / Submitted by Marcelo Roscamp (marcelo@ortopediapet.com) on 2017-11-28T14:37:45Z No. of bitstreams: 1 Dissertação_Marcelo_Roscamp.pdf: 9443012 bytes, checksum: 69bacbdda807a3e9fee0f785465385c3 (MD5) / Submitted by Marcelo Roscamp (marcelo@ortopediapet.com) on 2017-11-28T19:04:28Z No. of bitstreams: 1 Dissertação_Marcelo_Roscamp.pdf: 9443012 bytes, checksum: 69bacbdda807a3e9fee0f785465385c3 (MD5) / Submitted by Marcelo Roscamp (marcelo@ortopediapet.com) on 2017-11-30T18:58:21Z No. of bitstreams: 1 Dissertação_Marcelo_Roscamp.pdf: 9443012 bytes, checksum: 69bacbdda807a3e9fee0f785465385c3 (MD5) / Submitted by Marcelo Roscamp (marcelo@ortopediapet.com) on 2017-12-04T14:43:23Z No. of bitstreams: 1 Dissertação_Marcelo_Roscamp.pdf: 9443012 bytes, checksum: 69bacbdda807a3e9fee0f785465385c3 (MD5) / Submitted by Marcelo Roscamp (marcelo@ortopediapet.com) on 2017-12-05T14:11:15Z No. of bitstreams: 1 Dissertação_Marcelo_Roscamp.pdf: 9443012 bytes, checksum: 69bacbdda807a3e9fee0f785465385c3 (MD5) / Submitted by Marcelo Roscamp (marcelo@ortopediapet.com) on 2017-12-11T18:47:11Z No. of bitstreams: 1 Dissertação_Marcelo_Roscamp.pdf: 9443012 bytes, checksum: 69bacbdda807a3e9fee0f785465385c3 (MD5) / Approved for entry into archive by Alexandra Maria Donadon Lusser Segali null (alexmar@fcav.unesp.br) on 2017-12-13T12:16:42Z (GMT) No. of bitstreams: 1 roscamp_m_me_jabo.pdf: 9443012 bytes, checksum: 69bacbdda807a3e9fee0f785465385c3 (MD5) / Made available in DSpace on 2017-12-13T12:16:42Z (GMT). No. of bitstreams: 1 roscamp_m_me_jabo.pdf: 9443012 bytes, checksum: 69bacbdda807a3e9fee0f785465385c3 (MD5) Previous issue date: 2017-10-09 / A cirurgia piezoelétrica ou piezocirurgia é utilizada há várias décadas, porém em medicina veterinária são escassos os artigos publicados utilizando esta modalidade em cirurgias descompressivas da coluna vertebral de cães e gatos. Assim, aventou-se com esse trabalho investigar a aplicabilidade da mesma na realização da espondilectomia parcial ventral cervical (EPVC), comparando-a com a técnica convencional que utiliza brocas esféricas de alta rotação para o desgaste ósseo, utilizando o coelho (Oryctolagus cuniculus) como modelo experimental de cães e gatos. Para tanto foi utilizado o aparelho médico Mastersonic®, que possui duas peças de mão, uma piezoelétrica com ponteira ultrassônica tipo cinzel delicado (T1) e na outra, motor de alta rotação com brocas esférica de 2 mm (técnica convencional) (T2). A EPVC foi realizada entre a terceira e quarta vértebras cervicais e cada técnica foi realizada em 15 animais, devidamente anestesiados, os quais foram avaliados quanto à duração de cada etapa da cirurgia, variações de temperatura durante a execução da EPVC, visibilidade do campo cirúrgico, complicações trans e pós-operatórias e monitoração anestésica. Aos 14, 28 e 56 dias de pós-operatório (PO), cinco animais de cada tratamento foram submetidos à eutanásia e realizado estudo histopatológico do local da cirurgia, avaliando à resposta inflamatória, à cicatrização óssea e as lesões medulares. Os resultados mostraram que T1 demandou mais tempo para a execução da curetagem e maior perda de temperatura no foco cirúrgico durante a cirurgia. O tempo de acesso cirúrgico reduziu progressivamente em torno de 50% até o oitavo procedimento de cada tratamento (T1 e T2), e após isso se manteve com a mesma duração nos dois tratamentos. O tempo de uso do aparelho foi mais homogêneo em T1 e diminuiu progressivamente em T2, mas ao avaliar o tempo total da técnica de EPVC, não houve diferença entre os tratamentos. O T1 proporcionou melhor visibilidade do campo cirúrgico, com apenas um caso de sangramento ósseo, contra seis casos em T2. Observaram-se quatro casos de hemorragia de seio venoso vertebral durante a curetagem no T1 e dois casos no T2. Também ocorreram três casos de déficits proprioceptivos transitórios, com duração de até 72 horas no T1. A temperatura corporal e a taxa de uso do isoflurano decaíram com o tempo nos dois tratamentos, assim como a frequência cardíaca em T1. No estudo histopatológico observou-se resposta inflamatória mais ativa em T1 aos 14 dias de PO, porém aos 28 e 56 dias de PO foi semelhante entre os tratamentos, assim como a cicatrização óssea. Ainda houve mais lesões medulares com a piezocirurgia (T1), principalmente aos 14 e 28 dias de PO, com presença de malácia, esferócitos e células “Gitter”. Enquanto que na técnica convencional (T2), notou-se discreta degeneração Walleriana, apenas aos 14 dias de PO. Conclui-se que a piezocirurgia é aplicável na realização da EPVC com excelente visibilidade do campo operatório, facilidade de manuseio e rápida curva de aprendizagem, no entanto, demandou maior tempo para execução da espondilectomia e provocou mais complicações cirúrgicas e de lesões medulares, quando comparada à técnica convencional. / Piezoelectric surgery or piezosurgery has been used for several decades, but in veterinary medicine, articles published using this modality in decompressive surgery of the spine of dogs and cats are scarce. The aim of this study was to investigate the applicability of this technique to the performance of cervical ventral partial spondylectomy (CVPS), comparing it with the conventional technique using high-rotation spherical drills for bone wear using rabbit (Oryctolagus cuniculus) as an experimental model of dogs and cats.. For this was used Mastersonic® medical device that has two hand pieces, one piezoelectric type with ultrasonic delicate chisel tip (T1) and the other, high speed engine with spherical drills 2 mm (conventional technique) (T2). The CVPS was held between the third and fourth cervical vertebrae and each technique was performed on 15 animals, under anesthesia, which were evaluated for the duration of each stage of surgery, temperature variations during the execution of CVPS, the surgical field visibility, trans and postoperative complications and anesthetic monitoring. At 14, 28 and 56 postoperative days (PO), five animals per treatment were euthanized, and histological studies were carried to the surgical site by assessing the inflammatory response, and bone healing spinal injuries. The results showed that T1 required more time for curettage execution and highest loss of temperature at the surgical focus during surgery. Surgical access time progressively reduced by 50% until the eighth procedure of each treatment (T1 and T2), and after that it remained the same duration in both treatments. The time of use of the device was more homogeneous in T1 and progressively decreased in T2, but when evaluating the total time of the CVPS technique, there was no difference between treatments. The T1 provided better visibility of the surgical field, with only one case of bone bleeding, against six cases in T2. Four cases of vertebral venous sinus hemorrhage were seen during curettage in T1 and two cases in T2. There were also three cases of transient proprioceptive deficits, lasting up to 72 hours in T1. Body temperature and the rate of use of isoflurane declined over time in both treatments, as did heart rate in T1. Histopathological study there was more active inflammatory response in T1 at 14 days postoperatively, but after 28 and 56 days postoperatively was similar among treatments, as well as to bone healing. There were still more spinal cord injuries with the piezosurgery (T1), especially at 14 and 28 days of PO, with presence of malacia, spherocytes and Gitter cells. While the conventional technique (T2), it was noted discrete Wallerian degeneration, only at 14 days postoperatively. It is concluded that the piezosurgery is applicable in the performance of the CVPS with excellent visibility of the operative field, ease of handling and rapid learning curve, however, demanded more time for the execution of the spondylectomy and caused more surgical complications and spinal cord injuries, when compared to the conventional technique.
7

Ensaio clínico randomizado e cruzado entre a piezocirurgia e a técnica convencional rotatória para a exodontia de terceiros molares inferiores / Randomized crossover clinical trial between piezocirurgia and conventional technique for inferior third molar extraction

Frare, João Gilberto 07 November 2018 (has links)
A exodontia de terceiros molares inclusos produz um grau significativo de traumatismo para os tecidos moles e estruturas ósseas da cavidade oral, consequentemente resultando em uma reação inflamatória. Esta reação gera diversos sinais e sintomas clínicos pós operatórios como: dor, edema e limitação de abertura bucal que fazem parte da resposta inflamatória reparadora, mas que se exacerbada pode levar a grandes desconfortos. O objetivo do presente estudo foi verificar comparativamente a piezocirurgia e a técnica convencional rotatória quanto a variabilidade dos principais parâmetros clínicos, sistêmicos e locais, no pré, trans e no pós operatório da exodontias de terceiros molares inferiores. Foi realizado um estudo clínico randomizado, cruzado em 20 pacientes saudáveis com necessidade de exodontia de terceiros molares inclusos e/ou impactados bilateralmente de mesma dificuldade cirúrgica. O lado a ser operado foi alocado randomicamente para técnica ultrassônica ou rotatória. Foram analisadas as alterações hemodinâmicas, pressão arterial, frequência cardíaca e saturação de oxigênio pré, trans e pós operatórias. Os desfechos locais foram coletados no dia do procedimento e 24 horas após a cirurgia, nesse contexto foi investigada a máxima abertura bucal em milímetros e o edema facial em pontos anatômicos pré estabelecidos. A análise de dor foi registrada pelo próprio paciente por meio da escala visual analógica em ficha padronizada, assim como a quantidade de analgésicos consumida e os níveis de ansiedade. Os resultados mostraram que o tempo trans operatório pelo uso da piezocirurgia foi maior. Não houve grande variabilidade nos parâmetros hemodinâmicos. A técnica ultrassônica provocou limitação de abertura de boca semelhante à técnica convencional. Gerou menor edema pós operatório em uma das dimensões lineares. Não promoveu níveis menores de dor pós operatória, além disso pode aumentar o grau de ansiedade do paciente. Concluímos que para as osteotomias nas exodontias de terceiros molares inferiores, a piezocirurgia mostrou ser comparável a técnica convencional. O emprego de uma ou outra técnica deve ser uma opção pessoal do cirurgião. / The removal of third molars leads a significant degree of trauma to soft tissues and bone structures of oral cavity, consequently results in an inflammatory reaction. This reaction generates several clinical signs and post-operative symptoms such as: pain, edema and oral aperture limitation that are part of the inflammatory response. If exacerbated, this response can lead to a great discomfort. The aim of this study was to compare, systemic and local parameters variations, between the piezosurgery and the conventional rotational technique for third molar removal. A randomized, crossover clinical trial was carried out in 20 healthy patients with the necessity for bilateral impacted third molars extraction with the same surgical difficulty. The side to be operated was allocated randomly for ultrasonic or conventional rotatory technique. Hemodynamic variations as: blood pressure, heart rate and oxygen saturation were analyzed in different moments. The local outcomes: maximum oral aperture and facial edema were measured on the day of the procedure and 24 hours after the surgery. Post-operative pain scores were recorded by the patient using a visual analogical scale in standardized diary, as well as anxiety levels and the number of painkillers intake. The results showed that the trans-operative period with the use of piezosurgery was higher. There was no great variability at the hemodynamic parameters. The ultrasonic technique caused a mouth-aperture limitation like the conventional technique and it generated minor post-operative edema in one of the linear dimensions. It did not promote minor levels of post-operative pain, moreover it can increase the anxiety level of the patient. We concluded that for osteotomies in the third molar surgery, piezosurgery shows to be equivalent to conventional technique. The employment of one or another technique should be a personal decision of the surgeon.

Page generated in 0.0585 seconds