• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 178
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 185
  • 102
  • 72
  • 65
  • 49
  • 49
  • 48
  • 47
  • 47
  • 45
  • 45
  • 42
  • 42
  • 41
  • 39
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Estudo das propriedades mecânicas e análise da resistência à fratura de resina de metacrilato reforçada com fibra de vidro e partículas de carga utilizada para confecção de pinos intrarradiculares / Study of mechanical properties and analysis of fracture resistance of a methacrylate resin reinforced with fiberglass and filler particles used for making intracanal posts

Favarão, Isabella Negro 06 February 2014 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2016-09-20T11:52:54Z No. of bitstreams: 2 Dissertação - Isabella Negro Favarão - 2014.pdf: 1147871 bytes, checksum: 0e08616a9e1bff5fb2e39258564e5493 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-09-20T11:53:59Z (GMT) No. of bitstreams: 2 Dissertação - Isabella Negro Favarão - 2014.pdf: 1147871 bytes, checksum: 0e08616a9e1bff5fb2e39258564e5493 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2016-09-20T11:53:59Z (GMT). No. of bitstreams: 2 Dissertação - Isabella Negro Favarão - 2014.pdf: 1147871 bytes, checksum: 0e08616a9e1bff5fb2e39258564e5493 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2014-02-06 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The aim of this study was to characterize the mechanical properties (Flexural strength, Diametral tensile strength, Knoop hardness, Young`s modulus, and Poisson's ratio) of a new experimental composite reinforced with glass fiber, and evaluate the fracture resistance and failure mode of bovine roots post-restored with a new experimental composite produce in direct or indirect (laboratory) mode and compare them with prefabricated fiber glass posts. Experimental composite specimens (22.5% resin, 30% 3mm-short silanized glass fibers, and 47.5% of filler particles) were prepared and tested in a universal testing machine according to the particular methodology of each test, scanning electron microscopy analysis was performed on samples fractured in bending test. Thirty endodontically treated bovine roots were divided into 3 groups (n = 10): PFP: prefabricated fiber glass posts EXP-DIR: posts made of experimental material directly polymerised into the root canal EXP-IND: posts made of experimental material indirectly polymerised. Specimens were subjected to compression load (0.5 mm/min), maximum load recorded in Newton, and fracture ranked as the failure mode. Descriptive analyzes showed averages: 259.91 ± 26.01 MPa (Flexural strength); 31.05 ± 2.97 MPa (Diametral Tensile strength); 135.6 ± 24.8 KHN (Knoop Hardness), 5.6 ± 0.95 GPa (Young`s modulus), 0.34 ± 0.02 (Poisson's ratio). ANOVA and Tukey analyzes showed statistical difference for fracture resistance (p <0.05): PFP (620.72 ± 59.29)A, EXP-IND (506.54 ± 27.07)B, EXP-DIR (157.76 ± 32.34)C. The developed composite showed appropriate mechanical properties and feasibility for production of intracanal posts, however dependent on the method of production, being the indirect method the best. / O objetivo deste estudo foi caracterizar as propriedades mecânicas (Resistência à Flexão, Resistência à Tração Diametral, Dureza Knoop, Módulo de Elasticidade, e Coeficiente de Poisson) de um novo compósito experimental reforçado com fibra de vidro polimerizado de maneira convencional, e avaliar a resistência e padrão de fratura de raízes de incisivos bovinos restauradas com pinos confeccionados com o novo compósito experimental de maneira direta ou indireta (laboratorial) e compará-las com pinos de fibra de vidro pré-fabricados. Amostras do compósito experimental (22,5% de resina, 30% de fibra de vidro curta silanizada (3mm), e 47,5% de partículas de carga) foram confeccionadas e testadas em máquina de ensaio universal de acordo com a metodologia específica de cada teste; análise em Microscopia Eletrônica de Varredura foi realizada nas amostras fraturadas no teste de flexão. Trinta raízes bovinas tratadas endodonticamente foram distribuídas em 3 grupos (n=10): PFP: pino de fibra de vidro pré-fabricado; EXP-DIR: pino de fibra de vidro confeccionado com material experimental polimerizado de forma direta no canal radicular; EXP-IND: pino de fibra de vidro confeccionado com o material experimental polimerizado de forma indireta. Os espécimes foram submetidos à carga compressiva (0,5 mm/min), carga máxima registrada em Newton, e classificados quanto ao padrão de fratura. Análises descritivas demonstraram médias: 259,91±26,01 MPa (Resistência Flexural); 31,05±2,97 MPa (Tração Diametral); 135,6±24,8 KHN (Dureza Knoop); 5,6±0,95 GPa (Módulo de Elasticidade); 0,34±0,02 (Coeficiente de Poisson). Análises com ANOVA e Tukey demonstraram diferença estatística (p<0,05) para o teste de resistência à fratura: PFP (620,72±59,29)A, EXP-IND (506,54±27,07)B, EXP-DIR (157,76±32,34)C. O compósito experimental desenvolvido demonstrou propriedades mecânicas adequadas e viabilidade para à confecção de retentores intrarradiculares, entretanto dependente do método de confecção, sendo a confecção indireta o melhor método.
132

RESISTÊNCIA À FRATURA DE DENTES COM DIFERENTES GRAUS DE FRAGILIZAÇÃO RADICULAR RECONSTRUÍDOS COM OU SEM PINOS ACESSÓRIOS / FRACTURE STRENGTH OF WEAKENED TEETH RESTORED WITH OR WITHOUT ACCESSORY POSTS.

Rosa, Ricardo Abreu da 11 March 2010 (has links)
At this work, fracture strength of bovine teeth with different weakened root levels and rebuilded with glass fiber posts used in a unique way or associated with accessory glass fiber posts was evaluated. Fifty bovine mandibular incisors with similar mesio-distal and bucco-lingual dimensions were used at the study. They were sectioned at 14 mm from the apex and the pulp was removed. Teeth were fixed in acrylic resin blocks, then they were allocated into 5 groups: G1) teeth with normal root canal enlargement and glass fiber post Exacto # 3 (2 mm cervical diameter and 1.1 mm apical diameter (control group); G2) medium root canal enlargement and glass fiber post Exacto # 3; G3) medium root canal enlargement and glass fiber post Exacto # 3 associated with two accessory glass fiber post; G4) wide root canal enlargement and glass fiber post Exacto # 3; G5) wide root canal enlargement and glass fiber post Exacto # 3 associated with five accessory glass fiber posts. Specimens from group 1 were prepared with burns # 3 from Exacto Kit (apical diameter: 1.1 mm and 10 mm diameter: 2 mm) at 10 mm of depth. Specimens from group 2 and 3 were prepared with the same bur and depth than group 1, however the cervical 5 mm were prepared with diamonds burs 3018 HL (diameter 2.9 mm). Specimens from group 4 and 5 were prepared with the same burs of groups 3 and 4, nevertheless remained just 1 mm of dentinal thickness at cervical 5 mm and measured with digital caliper. The post luting process was made with Scotch Bond Multipurpose and RelyX ARC. Resin composite cores with Filtek Z-350 and metallic crowns were made. The specimens were stored at distillated water during 72 hours at 370C until use at fracture strength test. A universal testing machine (Emic) was used and the specimens were loaded at 1350 with the teeth long axis at crosshead speed 0.5 mm/min. The results did not indicated difference statistically significant among the groups (ANOVA 1-factor, α = 0.05). All the groups showed predominant failure patterns favorable to remaining teeth. / No presente trabalho foi avaliada a resistência à fratura de dentes bovinos com diferentes graus de alargamento do conduto radicular e reconstruídos com pinos de fibra de vidro utilizados isoladamente ou associados a pinos acessórios de fibra de vidro. Foram selecionados 50 incisivos inferiores bovinos, de dimensões mésio-distal e vestíbulo-lingual similares, seccionados transversalmente a 14 mm do ápice radicular. O tecido pulpar foi removido e os dentes foram fixados em blocos de resina acrílica, sendo a seguir distribuídos aleatoriamente em 5 grupos: G1) conduto com alargamento normal e cimentação de pino de fibra de vidro Exacto n0 3, que possui 2 mm diâmetro na porção cervical e 1,1 mm de diâmetro apical (grupo controle); G2) conduto medianamente alargado e cimentação do mesmo pino de fibra de vidro usado no grupo 1 (alargamento médio); G3) conduto medianamente alargado e cimentação de pino de fibra de vidro Exacto n0 3 associado a dois pinos de fibras de vidro acessórios Reforpin ; G4) conduto amplamente alargado e cimentação de pino de fibra de vidro Exacto n0 3 (alargamento amplo); G5) conduto amplamente alargado e cimentação de pino de fibra de vidro principal Exacto n0 3 associado a 5 pinos acessórios Reforpin (alargamento amplo). Os espécimes do grupo 1 tiveram seus condutos preparados em 10 mm de profundidade utilizando broca n0 3 do sistema Exacto (diâmetro extremidade apical: 1,1 mm; diâmetro em 10 mm: 2 mm). Os espécimes do grupo 2 e 3 foram preparados com a mesma broca do sistema de pinos em profundidade de preparo idêntica ao grupo 1, associado ao preparo dos 5 mm cervicais com pontas diamantadas 3018 HL (no diâmetro da broca 2,9 mm). Nos espécimes dos grupos 4 e 5 foram utilizadas as mesmas pontas diamantadas dos grupos 2 e 3, entretanto o desgaste dos 5 mm cervicais foi realizado de modo que permanecesse espessura dentinária radicular de apenas 1 mm, verificada através de paquímetro digital. A cimentação dos pinos foi realizada com o sistema adesivo Scotch Bond Multiuso Plus e cimento resinoso RelyX ARC. As porções coronárias dos núcleos foram reconstruídas com resina composta Filtek Z-350 e coroas totais metálicas foram cimentadas com cimento de ionômero de vidro modificado por resina RelyX Luting sobre os núcleos de preenchimento. Os espécimes foram armazenados em água destilada durante 72 horas a 370C até serem submetidos ao teste de compressão mecânica. Para tal, foi utilizada máquina de ensaios universal Emic e aplicação da carga em angulação de 1350 em relação ao longo eixo do dente, à velocidade de 0,5 mm/min. Os resultados não indicaram diferença estatística significativa entre os grupos testados (ANOVA 1-fator, α = 0,05). Todos os grupos apresentaram predomínio de falhas favoráveis para o remanescente dentário.
133

Estudo, in vitro, da influência da técnica e do aparelho de fotopolimerização na resistência de união de pinos intra-radiculares / In vitro study of influence of technique and light curing unit in retention force of fiber post system

Nagase, Denis Yudi 04 March 2010 (has links)
Objetivo: Este estudo se propõe a verificar a influencia do tipo de luz fotopolimerizadora na força de retenção de pinos intra-radiculares, tanto na técnica direta como na direta indireta. Métodos: 40 raízes de dentes bovinos com comprimento de 12 mm foram tratadas endodonticamente e divididas aleatoriamente em 4 grupos de acordo com a técnica de obtenção dos pinos e luz fotopolimerizadora (n=10): grupo 1 (técnica direta associada à lâmpada halogena); grupo 2 (técnica direta ao LED); grupo 3 (técnica direta-indireta associada à lampada halógena); e grupo 4 (técnica direta-indireta associada ao LED). A força de retenção foi determinada através do teste de tração usando Universal Testing Machine (Instron). Todos os dados foram analisados usando one-way analysis of variance (ANOVA) com a significância de p<0.05 e complementadas com teste de Tukey. Após o teste, as interfaces adesivas onde ocorreram as falhas foram examinadas e classificadas. Resultado: Os grupos 3 (246,05N ± 29,51) e 4 (241,60N ± 28,95) não apresentaram força de retenção estatisticamente diferente mas foram maiores que os grupos 1 (142,30N ± 25,60) e 2 (178,56N ± 25,67). A maior parte das fraturas ocorreu na interface dentina/resina. Conclusão: Com base nos resultados obtidos, concluímos que o método direto-indireto proporcionou a melhor retenção dos pinos de fibra de vidro. / Objectives: The purpose of this study is to verify the influence of light curing type on retention force of direct technique and direct-indirect technique. Methods: Fourth bovine single root teeth with 12mm of length were used in this study. The roots were endodontically treated and randomly divided in four groups according to the light curing unit and technique used: group 1(direct technique, halogen lamp), group 2(direct technique, LED), group 3(direct-indirect technique, halogen lamp), group 4(direct-indirect technique, lamp). The retention force was determined sing a Universal Testing Machine (Instron). All data were analyzed using one-way analysis of variance (ANOVA) and Tukey test. After the test, the failure was examined and classified according to the fracture place: post/ resin; resin/dentin; mix. Results: Group 3 (246,05N ± 29,51) and 4(241,60N ± 28,95)4 (95,18N) did not show statistically difference but presented higher retention force than group 1 (142,30N ± 25,60) and 2 (178,56N ± 25,67). Most of fracture occurred in interface between dentin/resin. Conclusion: Based on the obtained results, it was concluded that adhesive cementation technique influenced in the retention of glass fiber post.
134

Fatores que influenciam na resistência de união - ensaios push out e pull out - de pinos intra-radiculares. Estudo in vitro / Factors that influence on fiber post bond strength - push out and pull out tests. In vitro study

Nagase, Denis Yudi 03 July 2012 (has links)
Objetivo: Este estudo se propõe a verificar a influência do adesivo, material de preenchimento e hibridização da dentina na força de retenção de pinos intra-radiculares na técnica direta indireta e comparar o teste de tração de push out com o pull out. Métodos: 60 raízes de dentes bovinos com comprimento de 12 mm foram tratadas endodonticamente e divididas aleatoriamente em 6 grupos (n=10): grupo 1 (técnica direta-indireta, adesivo fotopolimerizável, cimento resinoso, teste de pull out); grupo 2 (idem ao grupo 1 porém o cimento resinoso foi substituído pela resina composta); grupo 3 (idem ao grupo anterior porém o adesivo fotopolimerizável foi substituído pelo químico); grupo 4 (idem ao anterior porém o teste utilizado foi o de push out); grupo 5 (idem ao grupo anterior porém o adesivo utilizado foi o auto condicionante); e grupo 6 (idem ao grupo anterior porém a dentina foi pré hibridizada). A força de retenção foi determinada através do teste de tração usando Universal Testing Machine (Instron). Todos os dados foram analisados usando one-way analysis of variance (ANOVA) com a significância de p<0.05 e complementadas com teste de Tukey. Após o teste, as interfaces adesivas onde ocorreram as falhas foram examinadas e classificadas. Resultado: Houve diferença estatística na comparação de materiais (adesivo, material de preenchimento). A hibridização da dentina não apresentou melhoras na retenção dos pinos . A maior parte das fraturas ocorreu na interface dentina/resina. Conclusão: Com base nos resultados obtidos, concluímos que material de preenchimento, o tipo de adesivo, influenciaram na retenção de pinos de fibra; e a pré-hibridização da dentina não apresentou melhoras a retenção dos pinos. O teste de push out apresentou mais detalhes para verificar o valor da adesão de cada terço da raiz; e o teste de pull out, para a força de retenção do pino ao longo do interior do conduto e o tipo de falha. / Objective: The aims of this study is to verify the influence of adhesive, filling material and dentin hybridization on fiber post retention force in diretc -indirect technique and compare the tensile test of push out with pull out. Methods: 60 bovine single roots with a length of 12 mm were endodontically treated and randomly divided into 6 groups (n = 10): group 1 (direct-indirect technique, light-curing adhesive, resin cement, pull out test), group 2 (same as group 1 but the resin cement was replaced by composite resin), group 3 (same as previous group but the light-curing adhesive was replaced by the chemical), group 4 (same as group 3 but the test was used was push out test), group 5 (same as group 4 but the adhesive used was the self etching) and Group 6 (same as previous group but the dentin was pre-hybridized). The retention force was determined by Universal Testing Machine (Instron). All data were analyzed using one-way analysis of variance (ANOVA) with significance of p <0.05 and complemented with Tukey test. After testing, the adhesive interfaces were examined and classifie. Result: There was a significant difference between comparison of materials (adhesive and filling material). The hybridization of dentin showed no improvement in the retention post. Most fractures occurred at the interface dentin / resin. Conclusion: Based on the results, we conclude that filling material, adhesive, influenced the retention of fiber posts, and the prehybridization of dentin did not improve the retention of fiber post. The push out test showed more details to verify the bonding between the post and dentin, and the pull out test for the retention force of the post inside the canal.
135

Avaliação da espessura de cimento e resistência adesiva de pinos de fibra de vidro cônicos em preparo para retentor intra-radicular realizados com uma ponta ultrassônica desenvolvida / Assessment of cement thickness and bond strength of circular fiber posts in post space preparations with an ultrasonic tip developed

Cardenas, José Edgar Valdivia 30 October 2017 (has links)
Preparos para retentores intra-radiculares mais conservadores evitam desgaste desnecessário da estrutura dentinária, requer menos cimento e podem melhorar a retenção adesiva do pino. Assim o objetivo deste estudo foi avaliar a espessura de cimento ea resistência adesiva de pinos de fibra de vidro cônicos em preparo para retentor intra-radicular realizados com uma ponta ultrassônica desenvolvida. Trinta incisivos laterais superiores foram preparados com limas reciprocantes Wave One Gold (Dentsply Sirona, Ballaigues, Suiça) e aleatoriamente divididos em 2 grupos (n=15) de acordo com a técnica de preparo para pino: grupo US foram preparados com uma ponta ultrassônica desenvolvida, e grupo WP (controle) com a broca recomendada pelo fabricante do pino. Os pinos de fibra de vidro cônicos WhitePost DC 0.5 (FGM, Joinville, SC, Brasil) foram cimentados utilizando cimento resinoso dual nos terços cervical e médio do canal radicular. Isto posto, todos os espécimes foram seccionados transversalmente em três seções (cervical, média e apical do pino) para análise da área de cimento resinoso ao redor do pino que foi calculada através do programa AutoCAD, em seguida, para avaliar a resistência adesiva, o teste de cisalhamento por extrusão foi aplicado através de uma maquina de ensaio universal numa velocidade média de 0.5 mm/min até o deslocamento do conjunto restaurador intra-radicular e o tipo de falha avaliado por estereomicroscopia. A comparação entre grupos e entre terços da área de cimento e resistência adesiva foram analisadas pelo teste t independente e Anova com Tukey; e os tipos de falha entre os grupos por Mann-Whitney, todos com nível de significância de 5%. No grupo ultrassônico foi observado a menor quantidade de cimento (p<0.05) e a resistência adesiva nos diferentes grupos e terços se manifestou maior somente no terço apical do grupo ultrassônico (p<0.05). Falha adesiva entre cimento e dentina foi a mais prevalente do terço cervical e apical do grupo US e cervical de grupo WP. Falha adesiva entre cimento e pino foi a mais prevalente nos demais terços. Conclui-se que o preparo para retentor com a ponta ultrassônica desenvolvida requer menor quantidade de cimento e influencia na melhor resistência de união no terço apical do pino de fibra de vidro. / Conservative post space preparations for intra-radicular retainers prevent unnecessary desgaste of the dentin structure, require less cement and improve bond strength of the post. The aim of this study was to evaluate the influence of resin cement thickness and bond strength of prefabricated glass fiber circular postin post space preparations with an ultrasonic tip developed. Thirtymaxillarylateral incisors were prepared with Wave One Gold reciprocating files (Dentsply Sirona, Ballaigues, Switzerland) and randomly divided into 2 groups (n=15) according to the post preparation technique: gruoup US was prepared with an ultrasonic tip developed and group WP (control) with the drill recommended by the post fabricant. Every glass fiber posts WhitePost DC 0.5 (FGM, Joinville, SC, Brazil) was cemented using dual polymerizing resin cement in the cervical and middle thirdof the root canal. After that, every specimen was sectioned transversally into three sections(cervical, middle and apical of the post) and the resin cement thickness area was calculated with AutoCAD program, the bond strength test was done with an universal testing machineat medium velocity 0.5 mm/min and the failure pattern after the test was analyzed with stereomicroscopy. Datas obtained were analyzed statistically using Student\'s t-Test, ANOVA,andTukey\'s test. The comparison of failure modes between the groups in the different thirds was done using Mann-Whitney test, All of those at a 5% significance. Ultrasonic group presented thinnest layer of cement in all thirds (p<0,05), which also obtained a higher bond strength only in apical third (p<0,05). Adhesive failurebetween cement and dentinwas the most prevalent of the cervical and apical third of G1 and cervical of G2.Adhesive failure between cement and post was the most prevalent in the others thirds. It can be concluded that the postpreparation with the ultrasonic tip developed provides a smaller thickness of resin cement that influenced thebond strength in the apical third of the glass fiber post.
136

Avaliação da resistência à fratura de dentes endodonticamente tratados, reconstituídos com pinos intra-radiculares, quando submetidos à ciclagem dinâmica / Evaluation of the fracture strength of endodontically treated teeth, reconstructed with post and cores, when submitted to the dynamic loading

Fernando Furtado Antunes de Freitas 26 November 2007 (has links)
Neste estudo, foi avaliada a resistência à fratura de dentes que, já tratados endodonticamente, foram reconstruídos proteticamente com uma coroa de liga de NiCr (Verabond II), a qual era apoiada sobre núcleos compostos por diferentes materiais, obtidos por diferentes técnicas, cimentados no remanescente radicular com o ionômero de vidro Rely X Lutting 2, o qual é acrescido de resina composta. Esses núcleos eram do tipo metálico fundido, no grupo NMF; no grupo ANATO, a resina composta Filtek Z250 (3M ESPE, St. Paul-MN, USA) constituía o núcleo, contendo um pino de fibra de vidro (Reforpost Fibra de Vidro RX, Ângelus Indústria de Produtos Odontológicos Ltda.,Londrina-PR); este mesmo tipo de pino era utilizado no grupo PFFV, sendo diretamente cimentado, sem acréscimo de resina; finalmente, no grupo PFM, um pino metálico (no 064, FKG Dentaire S. A., La Chaux-de-Fonds, Swiss) era cimentado da mesma maneira descrita para o grupo anterior. Os remanescentes radiculares eram provenientes de dentes caninos superiores humanos, distribuídos aleatoriamente, compondo assim os quatro grupos, cada um com 10 espécimes: Os espécimes, após 24 horas da cimentação, foram submetidos a esforços cíclicos, em uma Máquina Eletro-Mecânica de Fadiga, aplicados no sentido do longo eixo dental, com carga de 20 N, na freqüência de 2,0 Hz, assim perfazendo um total de 250.000 ciclos. Excetuando-se 2 corpos-de-prova cujos núcleos soltaram-se da raiz, durante a carga cíclica, todos os demais foram submetidos a uma carga de compressão, numa máquina universal de ensaios (Kratos - Dinamômetros Ltda. São Paulo-SP), regulada na velocidade de 0,5 mm/min, com a força aplicada na face palatina da coroa, num ângulo de 45º em relação ao longo eixo dental, até a ocorrência da fratura radicular. Os valores de resistência encontrados foram os seguintes, em ordem decrescente: 47,677 kgf para o grupo NMF, 34,921 kgf para o PFM, 31,354 kgf para o PFFV e, 27,172 kgf para o ANATO. A análise de variância aplicada aos valores originais apontou diferença entre os grupos estudados e um subseqüente teste de Tukey (p<0,05) permitiu verificar semelhanças entre todos eles, com diferença significante apenas entre os grupos NMF e ANATO. / In this study, was evaluated the strength of endodontically treated teeth, had been reconstructed with a crown of NiCr alloy (Verabond II), which was supported by a post and core for different materials, gotten for different techniques, cemented in the root with the glass ionomer Rely X Lutting 2, which is increased of composed resin. These diferents post and cores were of the casting metallic type, in group NMF; in group ANATO, the composed resin Filtek Z250 (3M ESPE, St. Paul-MN, USA) was the core, contend a glass fiber post (Reforpost Fibra de Vidro RX, Ângelus Indústria de Produtos Odontológicos Ltda., Londrina - PR); this exactly type of post was used in group PFFV, being directly cemented, without resin addition on the core; finally, in group PFM, a metallic post (064, FKG Dentaire S. , La Chaux-of-Fonds, Swiss) were cemented in the same way described for the previous group. All the roots were proceeding from maxillary human canines, randomly distributed, thus composing the four groups, each one with 10 specimens: The specimens, after 24 hours of the cimentation, had been submitted the cyclical efforts, in an Electromechanical Machine of Fatigue, applied in the direction of the long dental axle, with load of 20 N, in the frequency of 2 Hz, thus occuring a total of 250.000 cycles. Excepting 2 body-of-test whose post and cores had been freed of the root, during the cyclical load, all excessively had been submitted to a compression load, in a universal machine of assays (Kratos - Ltda. Dinamômetros. São Paulo - SP), regulated in the speed of 0,5 mm/min, with the force applied in the lingual face of the crown, in an angle of 45º in relation to the long dental axle, until the occurrence of the any root fracture. The joined values of resistance had been following, orderly the decreasing one: 47,677 kgf for group NMF, 34.921 kgf for the PFM, 31,354 kgf for the PFFV and, 27,172 kgf for the ANATO. The analysis of variance applied to the original values pointed difference between the studied groups and a subsequent Tukey test (p<0,05) it allowed to verify similarities between all they, with significant difference only between groups NMF and ANATO.
137

Estudo de um mecanismo de retenção/liberação utilizando liga com efeito de memória de forma.

Lizia Oliveira Acosta 00 December 2000 (has links)
Este trabalho descreve um estudo detalhado de um mecanismo de retenção/liberação de apêndices de satélites baseado em liga com efeito de memória de forma como alternativa para mecanismos pirotécnicos e de cera derretida. Foi utilizado como base para os requisitos de projeto do dispositivo, a configuração do satélite SACI II, projetado e fabricado pelo INPE - Instituto Nacional de Pesquisas Espaciais. O mecnismo tem como elementos básicos um pino de retenção e um atuador, montados no dispositivo de forma concêntrica. O funcionamento consiste em aquecer o atuador para que ele se expanda longitudinalmente. e ao recuperar sua forma, exerça uma força tal que rompa o pino de retenção, liberando os apêndices do satélite. Descreve-se inicialmente o mecanismo, apresentando-se todos os seus componenetes e respectivas funções. É aprofundada a descrição do atuardor, além da liga de níquel-titânio e o efeito de memória de forma. São discutidos os modelos de simulação, os quais consistem em um modelo de elementos finitos para o pino e um modelo térmico para o atuador e apresentados os ensaios de caracterização do pino e do atuador. O objetivo do trabalho é o desenvolvimento de uma metodologia de projeto que visa o dimensionamento preliminar dos componentes e a caracterização experimental do funcionamento do dispositivo. A partir de estudos teóricos e ensaios experimentais dos componentes e do protótipo foram obtidas informações que permitem definir uma seqüência de projeto a partir da concepção do mecanismo até a fabricação do protótipo.
138

Avaliação da resistência adesiva, por meio do teste de microtração, da interface pino de fibras de vidro / cimento / dentina radicular variando-se cimentos, adevivos dentinários e tempo de armazenamento / Microtensile bond strength of the post-resin / resin cement/ root dentin, varying resin cement, dentin bonding system and term water storage

Mendonça Neto, Tatiany de 10 September 2007 (has links)
Avaliou-se, por meio do teste de microtração, a resistência adesiva da interface pino de fibras de vidro /cimento/ dentina radicular, variando-se cimentos, adesivos dentinários e tempo de armazenamento. Foram utilizados dentes caninos humanos permanentes, extraídos por razões periodontais, que tiveram suas coroas seccionadas e as raízes preparadas para receber pinos de fibras de vidro (Fibrekor). Os dentes foram aleatoriamente divididos em grupos de dez, variando a técnica de cimentação adesiva e o tempo de armazenamento. Os cimentos utilizados foram (1) Panavia F, (2) Variolink II, (3) Enforce, com seus respectivos adesivos. Avaliou-se também a influência da aplicação de uma camada do adesivo hidrofóbico Scotchbond Multi-Purpose Plus [SBMP] com o cimento Panavia F e Enforce. Espécimes cimentados com Variolink II, Panavia F com SBMP e Enforce com SBMP foram armazenados em água destilada por três meses. Após a cimentação, as raízes foram seccionadas (longitudinalmente e horizontalmente) com disco diamantado obtendo-se espécimes de 1mm de espessura, dois por terço da raiz. Os espécimes foram submetidos ao teste de microtração e o modo de fratura analisado em microscópio óptico. Os valores médios de resistência (MPa) foram submetidos aos testes ANOVA e Tukey (p < 0,05). A análise estatística mostrou (1) diferenças significativas na resistência adesiva entre cimentos e terços sendo que na média total dos terços, o cimento Variolink II foi superior aos outros cimentos; (2) na análise por terços, o cimento Variolink II mostrou valores estatisticamente superiores para o terço cervical. Os cimentos Panavia F e Enforce apresentaram valores significativamente menores no terço cervical; (3) diferenças significativas na resistência adesiva, com a aplicação do adesivo hidrofóbico, independente da região avaliada; (4) diminuição significativa na resistência adesiva para os cimentos Variolink II e Enforce, após armazenamento em água; (5) após o armazenamento, o cimento Variolink II apresentou diminuição na resistência adesiva no terço cervical e o cimento Enforce nos terços médio e apical. O cimento Panavia F exibiu aumento significativo da resistência adesiva nos terços cervical e médio, e diminuição no terço apical; (6) em microscopia óptica, um padrão de fraturas predominantemente do tipo adesiva para todos os experimentos. / This study evaluated the microtensile bond strengths of the fiber post-resin / resin cement/ root dentin when were varied the resin cement, dentin bonding system and longterm water storage. Were used for this study, human canines teeth extracted for periodontal reasons. The crown was sectioned and root canals were prepared for fiber post-resin (Fibrekor). The teeth were randomly assigned into experimental groups (n = 10) when were varied the resin luting technique and term water storage. The resin cements were (1) Panavia F, (2) Variolink II, (3) Enforce mediated by their respective adhesives. Experimental groups, using Panavia F and Enforce, were prepared in the same way, except that the additional layer of a low-viscosity bonding resin (Scotchbond Multi-Purpose Plus [SBMP]) was placed on the bonded root dentin surface before luting the fiber post-resin. The teeth were stored for 3 months and subsequently prepared for microtensile bond strength testing. Beams of approximately 1mm2 were tested in tension at 0,5mm/mim in a universal testing machine. Fractured surfaces were examined under X 40 stereomicroscope to determine the mode of fracture. The data were divided into cervical, middle and apical regions and analyzed using ANOVA and Tukey\'s test (p < 0,05). The results of tensile bonding strengths showed (1) significant differences among resin cements and root dentin regions, were presented higher mean bond strength values to Variolink II, when compared with others; (2) the cervical third of Variolink II demonstrated higher values, to Panavia F and Enforce demonstrated lower values for that regions; (3) the application of the additional layer of the hydrophobic adhesive resulted in significant improved in the tensile bonding strength; (4) water storage for 3 months produced bond strengths that were significant lower for Variolink II e Enforce; (5) after storage, the Variolink II reduced bond strengths in the cervical third and Enforce in the middle and apical regions. The cervical and middle third of Panavia F presented higher mean bond strength values and apical regions demonstrated lower values; (6) No cohesive fractures within resin cement, fiber-reinforced composite resin post, or root dentin were identified.
139

AVALIAÇÃO DE PROPRIEDADES DE UNIÃO DE ADESIVOS UNIVERSAIS AO CANAL RADICULAR PREPARADO COM DIFERENTES INSTRUMENTOS ROTATÓRIOS / Evaluation of bonding properties of universal adhesives to root canal prepared with different rotary instruments

Bakaus, Thaís Emanuelle 16 February 2016 (has links)
Made available in DSpace on 2017-07-24T19:22:01Z (GMT). No. of bitstreams: 1 Thais Bakaus.pdf: 1611331 bytes, checksum: 4d80c0ed64cbca5d883bbdad39b16c0d (MD5) Previous issue date: 2016-02-16 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The objective of this study was to evaluate the influence of a rotating device used to prepare the root canal in the adhesion of glass fiber posts and evaluate different bonding strategies using universal adhesive systems. One hundred human premolars were used, which had their crowns removed and their roots endodontically treated. Initially, the roots were divided into four groups, according to a combination of the factors: a rotating device used to prepare the root canal - carbide bur (CB) and diamond bur (DB) and cementation system (universal adhesive system associated with its respective resin cement - Single Bond Universal / RelyX ARC (SB) and Prime&Bond elect / Enforce (PB). They were then divided into subgroups according to the bonding strategy: Self-etch (SE) or Etch-and-rise (E&R). Eight teeth per group were evaluated in bond strength (BS) by the push-out test and 4 in nanoleakage teeth (NL) by scanning electron microscopy (SEM), and the roots for these tests were transversely sectioned in 6 slices. The data of BS and NI for each cementation system were subjected to 2-way ANOVA and Tukey (α = 0.05). For BS, only the major factors were significant (p <0.05), and for both cementation systems, the highest BS values were observed for the preparation with DB compared to the CB and SE adhesion strategy compared with E&R. Likewise, the interaction was not significant for NL (p> 0.05). For the cementation system PB, the lowest values were observed for groups using DB compared to the CB and SE adhesion strategy compared to E&R. For the SB cementation system, only the rotating device main factor was significant (p = 0.01), whereas the DB resulted in lower average nanoleakage compared to the CB. It can be concluded that to improve the adhesion of glass fiber posts to root canal, diamond bur should be used to prepare the root canal; and, in general, universal adhesive systems must be used in self-etch mode to obtain satisfactory results on intracanal adhesion. / Avaliou-se a influência do instrumento rotatório utilizado para preparo do conduto radicular na adesão de pinos de fibra de vidro e diferentes estratégias de adesão utilizando sistemas adesivos universais. Foram utilizados 100 pré-molares inferiores humanos, os quais tiveram suas coroas removidas e suas raízes tratadas endodonticamente. Inicialmente, as raízes foram divididas em quatro grupos, de acordo com a combinação dos seguintes fatores: instrumento rotatório utilizado para preparo do conduto radicular - broca carbide (BC) e ponta diamantada (PD) e sistema de cimentação (sistema adesivo universal associado com seu respectivo cimento resinoso) - Single Bond Universal/RelyX ARC (SB) e Prime&Bond elect/Enforce (PB). Foram divididos então em subgrupos de acordo com a estratégia de adesão: Self-etch (SE) ou Etch-and-rinse (E&R). Oito dentes por grupo foram avaliados em resistência de união (RU) pelo teste de push-out e 4 dentes em nanoinfiltração (NI) por microscopia eletrônica de varredura (MEV), sendo que para esses testes as raízes foram seccionadas transversalmente em 6 fatias. Os dados de RU e NI para cada sistema de cimentação foram submetidos à ANOVA 2 fatores e Tukey (α=0,05). Para RU, apenas os fatores principais foram significativos (p < 0,05), sendo que para ambos os sistemas de cimentação maiores valores de RU foram observados para o preparo radicular com PD em comparação com a BC e para a estratégia de adesão SE comparada a E&R. Da mesma maneira, a interação não foi significativa para NI (p > 0,05). Para o sistema de cimentação PB menores valores foram observados para os grupos que utilizaram PD em comparação com a BC e para a estratégia de adesão SE em comparação com a E&R. Para o sistema de cimentação SB, apenas o fator principal instrumento rotatório foi significante (p = 0,01), sendo que a PD resultou em menores médias de nanoinfiltração em comparação com a BC. Pode-se concluir que para melhorar a adesão de pinos de fibra de vidro ao canal radicular pontas diamantadas devem ser utilizadas para o preparo do conduto radicular; e, de maneira geral, os sistemas adesivos universais devem ser utilizados na maneira self-etch para obterem resultados satisfatórios de adesão intracanal.
140

Influência do operador e agente cimentante na resistência de união de pinos de fibra de vidro à dentina radicular / Influence of the operator skill and luting agent on the bond strength of glass fiber post to radicular dentin.

Gomes, Giovana Mongruel 22 February 2010 (has links)
Made available in DSpace on 2017-07-24T19:22:11Z (GMT). No. of bitstreams: 1 Giovana Mongruel Gomes.pdf: 1282438 bytes, checksum: 3923d5e2e659866f5b3a3e842b6cceb4 (MD5) Previous issue date: 2010-02-22 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to evaluate the influence of the operator skill and resin cement system on the bond strength (BS) of glass fiber post to radicular dentin in different root thirds. Forty-eight extracted human upper central incisors were sectioned transversally immediately below the cement-enamel junction and the roots were treated endodontically. After one week, standardized post space cavities were prepared, and the roots randomly divided into two groups (n=24), according to the operator skill: professional (CD) vs academic (AC). The roots were then subdivided into three subgroups (n=8) according to the cementation system: CD1 and AC1 (Adper Scotchbond Multi-Purpose [SBMP] + RelyX ARC [ARC]), CD2 and AC2 (Adper Single Bond 2 [SB] + ARC) and CD3 and AC3 (RelyX U100 [U100]). The glass fiber post (Tenax Fiber Trans Esthetic Post System) were cemented following the manufacturer’s instructions of each cementation system. After water storage at 37o C for one week, each root was sectioned transversely into six 1-mm thick discs and the coronal (TC), middle (TM) and apical (TA) thirds of the root canal identified. A push-out test was carried out at a crosshead speed of 0,5 mm/min. The data were statistically analyzed by ANOVA and post-hoc Tukey's tests (p=0.05). The mean bond strengths (BS) values (MPa) and standard deviations (SD) of each subgroup were: CD1: 12.83±7.26; CD2: 11.46±4.22; CD3: 14.27±6.59; AC1: 9.70±4.37; AC2: 8.02±5.25 and AC3: 13.40±4.93. The BS of the CD and AC groups were 12.85±6.18 and 10.37±5.30, respectively. In regard to the root thirds, the means and SD were: TC: 14.46±5.55; TM: 10.04±5.07 and TA: 10.35±6.01. The mean and SD for the cementation systems were: SBMP + ARC: 11.27±6.13; SB + ARC: 9.74±5.03 and U100: 13.83±5.77. The highest BS means were obtained for CD group (p=0.004); no significant differences were detected among the three cementation systems for CD group (p=0.294); U100 cement reached statistically higher BS than the other cementation systems for AC group (p=0.001). The resin cement U100 was statistically higher than the other materials (p=0.0010) regardless the operator skill. The BS in the cervical third was statistically higher than in the TM and TA (p<0.0001). It can be concluded that the bond strength to the root canal is significantly affected by the operator skill, cementation system and root region. / O propósito desse estudo foi avaliar a influência do operador e do sistema de cimentação na resistência de união (RU) de pino de fibra de vidro à dentina radicular nos diferentes terços radiculares. Quarenta e oito incisivos centrais superiores humanos extraídos foram seccionados transversalmente imediatamente após a junção cemento-esmalte, e as raízes foram tratadas endodonticamente. Após uma semana, foi realizado o preparo padronizado dos condutos, e as raízes foram aleatoriamente divididas em dois grupos (n=24), de acordo com o operador: profissional (CD) vs acadêmico (AC). As raízes foram então subdivididas em três subgrupos cada (n=8) de acordo com o sistema de cimentação: CD1 e AC1 (Adper Scotchbond Multi-Purpose [SBMP] + RelyX ARC [ARC]), CD2 e AC2 (Adper Single Bond 2 [SB] + ARC) e CD3 e AC3 (RelyX U100 [U100]). Os pinos de fibra de vidro (Tenax Fiber Trans Esthetic Post System) foram cimentados de acordo com as recomendações dos fabricantes de cada sistema de cimentação. Após o armazenamento em água a 37o C por uma semana, cada raiz foi seccionada transversalmente em seis discos com 1 mm de espessura, e os terços coronário (TC), médio (TM) e apical (TA) do canal radicular foram identificados. O teste de push-out foi realizado a uma velocidade de 0,5 mm/min. Os dados obtidos foram analisados estatisticamente por meio do teste ANOVA e pós teste de Tukey (p=0,05). Os valores médios de RU (MPa) e desvio padrão (DP) para cada subgrupo foram: CD1: 12,83±7,26; CD2: 11,46±4,22; CD3: 14,27±6,59; AC1: 9,70±4,37; AC2: 8,02±5,25 e AC3: 13,40±4,93. A RU e DP para o grupo dos CD e dos AC foram 12,85±6,18 e 10,37±5,30, respectivamente. Em relação aos terços radiculares, as médias e o DP foram: TC: 14,46±5,55; TM: 10,04±5,07 e TA: 10,35± 6,01. As médias e DP para os sistemas de cimentação foram: SBMP + ARC: 11,27±6,13; SB + ARC: 9,74±5,03 e U100: 13,83±5,77. As maiores médias de RU foram obtidas para o grupo dos CD (p=0,004); não houve diferenças significativas entre os três sistemas de cimentação para o grupo dos CD (p=0,294); o cimento U100 foi estatisticamente superior aos demais sistemas de cimentação para o grupo dos AC (p=0,001). O cimento resinoso U100 foi estatisticamente superior aos demais sistemas de cimentação (p=0,001) independente do operador. A RU no terço coronário foi estatisticamente superior aos TM e TA (p<0,0001). Pode-se concluir que a resistência de união do canal radicular foi significativamente afetada pelo operador, sistema de cimentação e região radicular.

Page generated in 0.1068 seconds