• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 178
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 185
  • 102
  • 72
  • 65
  • 49
  • 49
  • 48
  • 47
  • 47
  • 45
  • 45
  • 42
  • 42
  • 41
  • 39
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Avaliação da resistência adesiva, por meio do teste de microtração, da interface pino de fibras de vidro / cimento / dentina radicular variando-se cimentos, adevivos dentinários e tempo de armazenamento / Microtensile bond strength of the post-resin / resin cement/ root dentin, varying resin cement, dentin bonding system and term water storage

Tatiany de Mendonça Neto 10 September 2007 (has links)
Avaliou-se, por meio do teste de microtração, a resistência adesiva da interface pino de fibras de vidro /cimento/ dentina radicular, variando-se cimentos, adesivos dentinários e tempo de armazenamento. Foram utilizados dentes caninos humanos permanentes, extraídos por razões periodontais, que tiveram suas coroas seccionadas e as raízes preparadas para receber pinos de fibras de vidro (Fibrekor). Os dentes foram aleatoriamente divididos em grupos de dez, variando a técnica de cimentação adesiva e o tempo de armazenamento. Os cimentos utilizados foram (1) Panavia F, (2) Variolink II, (3) Enforce, com seus respectivos adesivos. Avaliou-se também a influência da aplicação de uma camada do adesivo hidrofóbico Scotchbond Multi-Purpose Plus [SBMP] com o cimento Panavia F e Enforce. Espécimes cimentados com Variolink II, Panavia F com SBMP e Enforce com SBMP foram armazenados em água destilada por três meses. Após a cimentação, as raízes foram seccionadas (longitudinalmente e horizontalmente) com disco diamantado obtendo-se espécimes de 1mm de espessura, dois por terço da raiz. Os espécimes foram submetidos ao teste de microtração e o modo de fratura analisado em microscópio óptico. Os valores médios de resistência (MPa) foram submetidos aos testes ANOVA e Tukey (p < 0,05). A análise estatística mostrou (1) diferenças significativas na resistência adesiva entre cimentos e terços sendo que na média total dos terços, o cimento Variolink II foi superior aos outros cimentos; (2) na análise por terços, o cimento Variolink II mostrou valores estatisticamente superiores para o terço cervical. Os cimentos Panavia F e Enforce apresentaram valores significativamente menores no terço cervical; (3) diferenças significativas na resistência adesiva, com a aplicação do adesivo hidrofóbico, independente da região avaliada; (4) diminuição significativa na resistência adesiva para os cimentos Variolink II e Enforce, após armazenamento em água; (5) após o armazenamento, o cimento Variolink II apresentou diminuição na resistência adesiva no terço cervical e o cimento Enforce nos terços médio e apical. O cimento Panavia F exibiu aumento significativo da resistência adesiva nos terços cervical e médio, e diminuição no terço apical; (6) em microscopia óptica, um padrão de fraturas predominantemente do tipo adesiva para todos os experimentos. / This study evaluated the microtensile bond strengths of the fiber post-resin / resin cement/ root dentin when were varied the resin cement, dentin bonding system and longterm water storage. Were used for this study, human canines teeth extracted for periodontal reasons. The crown was sectioned and root canals were prepared for fiber post-resin (Fibrekor). The teeth were randomly assigned into experimental groups (n = 10) when were varied the resin luting technique and term water storage. The resin cements were (1) Panavia F, (2) Variolink II, (3) Enforce mediated by their respective adhesives. Experimental groups, using Panavia F and Enforce, were prepared in the same way, except that the additional layer of a low-viscosity bonding resin (Scotchbond Multi-Purpose Plus [SBMP]) was placed on the bonded root dentin surface before luting the fiber post-resin. The teeth were stored for 3 months and subsequently prepared for microtensile bond strength testing. Beams of approximately 1mm2 were tested in tension at 0,5mm/mim in a universal testing machine. Fractured surfaces were examined under X 40 stereomicroscope to determine the mode of fracture. The data were divided into cervical, middle and apical regions and analyzed using ANOVA and Tukey\'s test (p < 0,05). The results of tensile bonding strengths showed (1) significant differences among resin cements and root dentin regions, were presented higher mean bond strength values to Variolink II, when compared with others; (2) the cervical third of Variolink II demonstrated higher values, to Panavia F and Enforce demonstrated lower values for that regions; (3) the application of the additional layer of the hydrophobic adhesive resulted in significant improved in the tensile bonding strength; (4) water storage for 3 months produced bond strengths that were significant lower for Variolink II e Enforce; (5) after storage, the Variolink II reduced bond strengths in the cervical third and Enforce in the middle and apical regions. The cervical and middle third of Panavia F presented higher mean bond strength values and apical regions demonstrated lower values; (6) No cohesive fractures within resin cement, fiber-reinforced composite resin post, or root dentin were identified.
172

Resistência da união ao teste de push-out de cimentos resinosos auto-adesivos em dentina radicular / Push-out bond strength of self-adhesive resin cements on root dentin

Gonçalves, Mariella Agostinho 30 March 2012 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-05-18T14:35:18Z No. of bitstreams: 1 mariellaagostinhogoncalves.pdf: 2206097 bytes, checksum: 736acf1d28715f5b3a331257446b5b23 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-01T18:48:04Z (GMT) No. of bitstreams: 1 mariellaagostinhogoncalves.pdf: 2206097 bytes, checksum: 736acf1d28715f5b3a331257446b5b23 (MD5) / Made available in DSpace on 2016-07-01T18:48:04Z (GMT). No. of bitstreams: 1 mariellaagostinhogoncalves.pdf: 2206097 bytes, checksum: 736acf1d28715f5b3a331257446b5b23 (MD5) Previous issue date: 2012-03-30 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Neste estudo, avaliou-se a resistência da união ao push-out de dois cimentos resinosos auto-adesivos e de um cimento resinoso convencional em dentina radicular. Em 60 dentes terceiros molares humanos, tratados endodonticamente, um pino de fibra de vidro foi cimentado com um dos três cimentos resinosos. Cada raiz foi seccionada em sentido transversal para a obtenção de três fatias (dentina-pino) de 1 mm de espessura. As fatias, correspondentes aos terços cervical, médio e apical do canal radicular, foram armazenadas em água deionizada a 37 ºC, durante 24 horas ou 30 dias. Após o teste de push-out, os valores de resistência da união foram submetidos aos testes estatísticos ANOVA three way e Tuckey (p = 0,05) e os tipos de fratura foram avaliados através de microscopia eletrônica de varredura. A resistência da união do cimento resinoso auto-adesivo RelyX U100 foi superior à do cimento convencional RelyX ARC, após os dois períodos de armazenamento (p < 0,05). No terço cervical, os valores de resistência da união do cimento resinoso convencional RelyX ARC foram maiores que nos terços médio e apical (p < 0,05) na análise de 24 horas. Após 30 dias de armazenamento, os valores nos três terços radiculares não diferiram entre si. Os valores de resistência da união do cimento resinoso RelyX U100, nas três regiões do canal radicular, não diferiram entre si (p > 0,05), em ambos os momentos de avaliação. Após 24 horas, BisCem apresentou maior resistência da união no terço apical, seguido pelo terço cervical. Após 30 dias, os valores de resistência da união nos três terços radiculares não diferiram entre si (p > 0,05). RelyX U100 não sofreu alteração nos valores de resistência da união após 30 dias de envelhecimento (p > 0,05). BisCem não apresentou diferenças nos valores obtidos após 24 horas e 30 dias de envelhecimento nos terços cervical e médio (p > 0,05). Para RelyX ARC, o tempo de 30 dias reduziu os valores de resistência da união nos três terços radiculares. RelyX U100 e BisCem apresentaram maior número de falhas coesivas da zona de interação. Para RelyX ARC, observou-se maior número de falhas coesivas da camada híbrida. Concluiu-se que o cimento resinoso auto-adesivo RelyX U100 apresentou maior resistência da união que o cimento resinoso convencional RelyX ARC, nos três terços radiculares, nos dois momentos de avaliação. BisCem demonstrou resistência da união comparável a do cimento RelyX U100. O tempo de armazenamento por 30 dias provocou alteração na resistência da união dos cimentos resinosos RelyX ARC e BisCem. / This study evaluated the push-out bond strength of two self-adhesive resin cements and a conventional etch-and-rinse resin cement on root dentin. Sixty human third molars were endodontically treated and a glass fiber post was cemented with one of three resin cements. Each root was cut transversely to obtain three slices (dentin-post) of 1 mm thick. The slices of the cervical, middle and apical root canal were stored in deionized water at 37 °C for 24 hours or 30 days. After storage, the push-out test was performed. The values of bond strength were evaluated by ANOVA three way and Tuckey’ test (p = 0,05) and the types of fracture were evaluated by scanning electron microscopy. The bond strength of the self-adhesive resin cement RelyX U100 was superior to the RelyX ARC etch-and-rinse cement, after the two storage periods (p > 0.05). The analysis of 24 hours showed that at the cervical third, the values of bond strength of RelyX ARC were higher than that of the middle and apical thirds (p < 0.05). After 30 days of storage, the values at the three root thirds did not differ. The values of RelyX U100, on the three regions of the root canal did not differ, in both evaluations (p > 0.05). After 24 hours, BisCem showed higher bond strength at the apical third, followed by cervical. After 30 days, the values of bond strength at the three root thirds did not differ (p > 0.05). RelyX U100 did not exhibit changes in bond strength values after 30 days of storage (p > 0.05). BisCem showed no differences in the values obtained after 24 hours and 30 days of aging at the cervical and middle thirds (p > 0.05). The storage time of 30 days reduced the values of bond strength at the three root thirds of RelyX ARC. RelyX U100 e BisCem had the highest number of cohesive failures of the zone of interaction. RelyX ARC presented a higher number of cohesive failures of the hybrid layer were observed. It was concluded that the RelyX U100 self-adhesive resin cement showed higher bond strength than the conventional resin cement RelyX ARC, on the three root thirds, in both periods. BisCem showed bond strength comparable to RelyX U100. The storage time for 30 days caused changes on the bond strength of the RelyX ARC and BisCem resin cements.
173

Influência de materiais obturadores e agentes de limpeza na resistência da união e interface adesiva de pinos de fibra de vidro à dentina intrarradicular / Influence of filling materials and cleaning agents on bond strength and adhesion interface of glass fiber post to radicular dentin

Iwamoto, Alexsandra Shizue, 1987- 20 August 2018 (has links)
Orientadores: Fernanda Miori Pascon, Regina Maria Puppin Rontani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-20T05:29:10Z (GMT). No. of bitstreams: 1 Iwamoto_AlexsandraShizue_M.pdf: 5068520 bytes, checksum: 5edcd14cf180873ed3b9ce319f696504 (MD5) Previous issue date: 2012 / Resumo: O objetivo do estudo foi avaliar in vitro a influência de diferentes materiais obturadores e agentes de limpeza na resistência da união de pinos de fibra de vidro à dentina radicular e na qualidade da interface adesiva. 156 raízes de dentes bovinos decíduos foram selecionadas, preparadas endodonticamente e distribuídas em 4 grupos de acordo com os materiais obturadores (39 dentes): 1- Controle (sem material); 2- Pasta Calen® + óxido de zinco (OZ); 3- Pasta Vitapex®; 4- Pasta Calcipex II®. Após 7 dias, as raízes foram desobturadas e subdivididas de acordo com os agentes de limpeza (13 dentes): A - Controle (sem limpeza); B - Etanol a 70%; C - Tergenform®. A cimentação do pino foi realizada com cimento resinoso RelyXMR ARC após condicionamento com ácido fosfórico a 35 % e aplicação do sistema adesivo Adper Single BondTM 2. Os espécimes foram armazenados por 7 dias, seccionados e preparados para avaliação da resistência da união (n=10) e análise da interface por meio da infiltração por nitrato de prata (n=3). O teste push-out foi conduzido na máquina de ensaio universal EMIC com velocidade 0,5mm/min. Os dados obtidos em Kgf foram convertidos em MPa e submetidos à ANOVA dois fatores (materiais obturadores x agentes de limpeza) e ao teste Tukey (p<0,05). Amostras representativas dos grupos foram observadas em Microscopia Eletrônica de Varredura (MEV) após a realização do teste push-out para ilustrar a fratura ocorrida. Para avaliação qualitativa da interface adesiva entre dentina/cimento e cimento/pino, as áreas infiltradas pela solução de nitrato de prata foram observadas em MEV e mensuradas por um único examinador previamente calibrado (nível de coincidência intra-examinador=98%), calculadas em porcentagem e submetidas ao teste Kruskal-Wallis (p<0,05) e à análise descritiva. Para os resultados da resistência da união, verificou-se que houve interação entre os fatores de estudo (p=0.0043). A pasta Calen®+OZ e limpeza com etanol apresentou o maior valor de resistência da união, diferindo estatisticamente do grupo sem limpeza. Valores intermediários foram encontrados para a limpeza com Tergenform®. As pastas Vitapex® e Calcipex® não apresentaram diferenças entre os agentes de limpeza e menores valores de resistência da união foram para o grupo controle (sem material obturador) e limpeza com Tergenform®, diferindo dos outros agentes de limpeza. Observou-se que não houve diferença entre os grupos para a infiltração de prata nas interfaces adesivas entre cimento e dentina radicular, que variou de 20,63% a 56,62%. Dessa forma, pode-se concluir que: (1) os materiais obturadores e os agentes de limpeza interferiram na resistência da união de pinos de fibra de vidro e dentina radicular; (2) ao realizar a obturação do canal radicular com pasta Calen®+OZ o melhor agente de limpeza foi o etanol a 70%; (3) para as pastas Vitapex® e Calcipex II® não há necessidade de agentes de limpeza; e (4) todos os grupos sofreram infiltração na interface de união entre cimento/dentina radicular, independente dos materiais obturadores e agentes de limpeza estudados / Abstract: The aim of this in vitro study was to evaluate the post-cement-dentin adhesive interface quality and the effect of different filling materials and cleaning agents on the bond strength of glass fiber posts to primary root dentin. This study included 156 roots of bovine primary teeth which were endodontically treated and assigned to four groups (39 teeth each group) according to filling materials: 1 - control (no material); 2 - Calen® paste + zinc oxide (ZO); 3 - Vitapex® paste; and 4 - Calcipex II® paste. After seven days, the filling materials were removed and the roots for each material subdivided into 3 groups (13 teeth) according to cleaning agents: A - No cleaning (control); B - 70% ethanol; and C - Tergenform®. Glass fiber posts were luted using dual polymerized resin cement (RelyXMR ARC) after 35% acid etching, rinsing and application of the adhesive system (Adper Single BondTM 2). The specimens were stored for 7 days, sectioned and prepared for push-out bond strength test (n=10) and interface analysis by silver nitrate leakage (n=3). A push-out test was performed using a universal test machine (EMIC) at a crosshead speed of 0.5 mm/min. Data obtained in Kgf were converted into MPa and submitted to two-way ANOVA (filling materials x cleaning agents) and Tukey tests (p<0.05). After the push-out test, representative samples of the groups were submitted to scanning electron microscopy (SEM) to illustrate the failure modes. The adhesive interface between dentin/cement and cement/post were also analyzed by SEM. The leakage (expressed in percentage) was measured by a single examiner previously calibrated (intra-examiner coincidence level = 98%) using a silver nitrate solution. Data obtained for leakage were submitted to the Kruskal-Wallis test (p<0.05) and descriptive analysis. Interaction was observed between filling materials and cleaning agents, concerning bond strength values (p=0.0043). Calen® paste+ZO with 70% ethanol showed the highest values, significantly different from the groups using no cleaning agents. Vitapex® and Calcipex® showed no significant difference between cleaning agents. The lowest bond strength values were found for the control with Tergenform®. No statistical difference was observed between groups concerning silver leakage (20.63% to 56.62%) in the adhesive interface between cement and dentin. In conclusion, filling materials and cleaning agents influenced the bond strength, but not the adhesive interface between intracanal posts and root dentin; as a cleaning agent, 70% ethanol responded better to Calen® paste+ZO; cleaning agents are not required for Vitapex® and Calcipex®; all groups showed leakage in the adhesion interface between cement resin/dentin root, regardless of the filling materials and cleaning agents studied / Mestrado / Odontopediatria / Mestre em Odontologia
174

Influência da viscosidade do condicionador ácido na dentina radicular sobre a resistência de união de um sistema de cimentação adesivo. Avaliação por teste de push-out e MEV

Salas, Mabel Miluska Suca 10 June 2005 (has links)
Made available in DSpace on 2014-08-20T14:30:20Z (GMT). No. of bitstreams: 1 Mabel Salas_DISSERTACAO.pdf: 6552657 bytes, checksum: 11efe494170784ff76d8fc2f0dff8e56 (MD5) Previous issue date: 2005-06-10 / Actually different alternatives to restored teeth with endodontical treatment are propose, otherwise with the advented of adhesive systems their use as luting endodontical cements and bonding resin cement for fiber posts are common. However the inherent characteristics behavior of these materials and the different variances presented at root canal, turns them sensible to failure. The aime of the study was to evaluated: a) the influence of two luting cements: containing eugenol (Endofill) and containing resin materials (Ahplus) on dentin bonding strength using push-out test at cervical, medium and apical root dentin regions, using two different 37% phosphoric acid viscosities: gel and liquid: b) the effect of the total-etching acid process on the pattern observed of the conditioned dentine substrate, c) Characterize the dentinal surface at different root regions d) Classify the fracture patterns between the substrate and the resin cement at three root regions. One hundred and four uniradicular teeth without caries lesions, extracted by orthodontics or periodontal reasons, with 7mm of diameter and 14mm of length were selected, disinfected in 0,5% chloramine and storage in distillated water at 5ºC. Endodontical canal treatments were performed using the Step-back technique and obturated with Endofill and AHplus. The preparation of the post space was 11mm depth using standardized rotary instruments. The total-etching with the gel and liquid acid were performed. The fiber posts were marked at the same depth, cuted, dry and silanized. Then two coats of Prime&bond 2,1 previously mixed with the self-cure activator, were applied at the post surface and into de root canal, after 1 minute the post were photocured (halogen light intensity of 450mW). The resin cement was mixed and placed into de canal using a lentuloespiral instrument. The posts were placed and a static force of 5kg for 10 minutes were applied, after words both adhesive and cement were photocured for 40 seconds, storage for 24 h in 37ºC, and embedded in a poliestyren resin. Cross-sectional cuts were obtained for the push-out test. The test were performed at a crosshead speed of 0,5mm/min, and a plane 20 cylindrical point was applied at the post centre. The maxim load was calculated in Mpa. The adhesive area was calculated using a tapered-cone shaped formula. The results were subjected to statistical analysis using a ANOVA test for multiple variables and a Pos Doc test(p<0,05) Statistically significant differences were detected between all the evaluated criterias: acids, cements and regions, and when they were inter-relationated between them. It was concluded that the use of 37% of phosphoric acid in a liquid form, allows a better penetration into the root canal, a uniform decalcification, consequently enhancing the bonding strength of the root dentine, particularly at apical region. / Actualmente diversos tipos de alternativas para restaurar dentes submetidos a tratamento endodontico são propostos, dentre estes, sistemas adesivos resinosos cimentantes para uso endodontico e pinos de fibra. No entanto as carateristicas inerentes apresentadas por estes materiais e as diversas variáveis presentes em nível radicular os fazem sensíveis a falhas. O objetivo deste trabalho foi avaliar a influência do tipo de cimento endodôntico e da viscosidade do ácido sobre a resistência de união de um sistema adesivo utilizando pinos de fibra de vidro, mediante o teste push-out e MEV em três níveis radiculares: cervical, médio e apical. Foram selecionados 104 dentes uniradiculares sem cárie, extraídos por motivos periodontais ou ortodônticos. Os dentes foram desinfectados em cloramina 0,5% e armazenados em água destilada a 5ºC. Os tratamentos endodônticos foram padronizados com a técnica step-back, obturando-se com Ahplus ou com Endofill. Os preparos para os pinos foram de 11mm padronizando os instrumentos. O condicionamento com o ácido fosfórico a 37%, em gel ou em líquido, foi realizado em ambos grupos. Os pinos de vidro foram seccionados em 11 mm,, silanizados, cobertos com duas camadas de Prime&bond 2.1 misturado previamente com o ativador de autopolimerização. O cimento resinoso Enforce (Dentsply) foi misturado e aplicado no canal utilizando lentulo. O pino era inserido e aplicava-se uma força padronizada de 5kg durante 10 min e sendo polimerizados por 40 seg, e armazenados por 24 horas a 37ºC, incluídos em resina de polietileno, cortados em 6 discos transversais de 1,5mm e lixados. O teste de push-out foi com uma velocidade de 0,5 mm/min, a ponta ativa cilíndrica plana (0,9 mm de diâmetro) era aplicada no centro do pino. A carga máxima foi convertida em MPa.. As diferenças entre os grupos foram determinadas mediante a análise de variância de ANOVA de três critérios, teste de Post Hoc (p<0,05). De acordo com a análise de fratura foram observadas diferenças nos três terços estudados particularmente no terço apical. Segundo a análise de fratura, foram observados quatro padrões diferentes de fraturas. Todas as variáveis testadas influenciaram significativamente a 18 resistência de união. A região cervical produziu geralmente menores valores de união, quando era utilizado o ácido em gel. Por outro lado, quando era utilizado o ácido em líquido os valores de resistência aumentavam, podendo-se concluir que a utilização de ácido fosfórico 37% em líquido permite uma maior penetração do adesivo no canal radicular produzindo um aumento da resistência de união na dentina radicular, particularmente no terço apical.
175

EFEITO DE DIFERENTES SOLUÇÕES IRRIGADORAS SOBRE A RESISTÊNCIA ADESIVA DE PINOS DE FIBRA DE VIDRO COM UTILIZAÇÃO DE CIMENTO AUTOADESIVO / NEGATIVE INFLUENCE OF DIFFERENT IRRIGANTS ON BOND STRENGH OF FIBER POSTS CEMENTED WITH A SELF-ADHESIVE CEMENT

Seballos, Vívian Gehm 25 July 2016 (has links)
The purpose of this study is to evaluate the effect of different irrigatins on bond strength of fiber posts cemented with RelyX U200. Eighty single-rooted premolars were sectioned at 14 mm from the apex, prepared with ProTaper Universal system until F3 instrument, and filled with F3 master cone and AH Plus sealer. Root canal filling was partially removed, remaining 4 mm of guta-percha at the apical third. Specimens were randomly divided into 8 groups (n=10), according to the irrigant used during root canal preparation and before fiber post cementation (dentin surface treatment), as described: SS: 0,9% saline solution (control group); CHX: 2% chlorhexidine; 1%NaOCl: 1% sodium hypochlorite; 2,5%NaOCl: 2,5% sodium hypochlorite; 5%NaOCl: 5% sodium hypochlorite; 1%CaOCl: 1% calcium hypochlorite; 2,5%CaOCl: 2,5% calcium hypochlorite; e 5%CaOCl: 5% calcium hypochlorite. For each group, irrigation was performed continuously with 2ml. Exacto N2 glass fiber posts were cemented with RelyX U200. The specimens were sectioned providing 3 slices, one for each root third and the push-out test was performed. Optical microscopy was used to analyze the failure mode. Bond strength means were calculated and ANOVA and Bonferroni tests were used for statistical analysis. SS showed higher mean of bond strength values (11.47MPa), than all NaOCl and CaOCl groups, which showed similar values to CHX (7.56Mpa ± 2:47). Adhesive failures at cement/dentin interface were predominant (58.33%). NaOCl and CaOCl negatively affect the bond strength of fiber posts to root dentine when cemented with sef-adhesive resin cement; however the concentration of NaOCl and CaOCl did not affect this outcome. / Este estudo tem como objetivo avaliar o efeito de diferentes soluções irrigadoras sobre a resistência adesiva de pinos de fibra de vidro, cimentados com cimento autoadesivo RelyX U200. Foram utilizados 80 pré-molares inferiores humanos tiveram a coroa seccionada, padronizando-se o comprimento da raiz em 14 mm. Os condutos foram instrumentados com o sistema rotatório ProTaper até o instrumento F3, obturados com cimento endodôntico AH Plus e cones de guta-percha F3 do mesmo sistema, pela técnica do cone único. Os condutos foram desobturados até 10mm de profundidade, mantendo-se os 4mm apicais da obturação. As raízes foram aleatoriamente distribuídas em 8 grupos (n=10), de acordo com a solução irrigadora utilizada previamente à cimentação dos pinos: SS: solução salina 0,9% (grupo controle); CHX: clorexidina 2%; 1%NaOCl: hipoclorito de sódio 1%; 2,5%NaOCl: hipoclorito de sódio 2,5%; 5%NaOCl: hipoclorito de sódio 5%; 1%CaOCl: hipoclorito de cálcio 1%; 2,5%CaOCl: hipoclorito de cálcio 2,5%; e 5%CaOCl: hipoclorito de cálcio 5%. Para cada espécime, a irrigação foi realizada com 2ml da solução a cada troca de instrumento. Os pinos de fibra de vidro do Sistema Exacto Translúcido n02 foram silanizados e cimentados com o cimento resinoso autoadesivo RelyX U200. As raízes foram seccionadas na máquina de corte, de forma a obter 3 slices por espécime, sendo 1 slice para cada terço radicular. A seguir, os corpos de prova foram submetidos ao teste de push-out na máquina de ensaio universal EMIC. Para análise do padrão de falha, os espécimes foram analisados com microscopia óptica. A média de resistência adesiva de cada espécime foi calculada. Testes ANOVA e Bonferroni foram utilizados para analisar as diferenças entre os grupos. O grupo SS demonstrou a maior média de resistência adesiva, sendo superior aos grupos NaOCl e CaOCl (P <0.05), nos quais apresentaram valores semelhantes ao grupo CHX (7.56Mpa ± 2.47). As falhas adesivas cimento/dentina foram predominantes (58.33%). Concluímos que SS parece ser a solução mais adequada para limpeza do canal radicular previamente à cimentação de pinos de fibra cimentados com cimento autoadesivo RelyX U200. NaOCl e CaOCl diminuíram os valores de resistência adesiva dos pinos de fibra à dentina radicular e suas diferentes concentrações não afetaram este resultado.
176

"Efeito da terapia por ondas de choque na consolidação óssea após osseossíntese de fêmur com hastes bloqueadas: estudo experimental em cães (canis familiaris)" / Effect of extracorporeal shock wave therapy one bone healing after femur ostosynthesis with interlocking nails: experimental study in dogs (Canis familiaris)

Bassit, Ana Cristina Ferreira 14 September 2004 (has links)
O efeito da terapia por ondas de choque (TOC) na consolidação óssea, após osteotomias bilaterais dos fêmures e osteossínteses com hastes bloqueadas, foi estudado em 8 cães. Os fêmures direitos constituíram o grupo controle e os esquerdos, o grupo tratado, que recebeu 2000 pulsos de ondas de choque de 18 kV, energia de 5mJ (-6dB), na linha da fratura. Radiografias após 4, 8 e 12 semanas, revelaram maior proliferação periosteal no grupo tratado. Os resultados dos exames cintilográficos (razão tratado/controle), realizados na 2a, 4a, 6a, 8a, 10a e 12a semanas, foram estatisticamente superiores no grupo tratado. A TOC provocou aumento da atividade osteogênica na consolidação de fraturas agudas / The effect of extracorporeal shock wave therapy (ESWT) on bone healing, after bilateral femoral osteotomies and osteosynthesis with interlocking nails, was studied in 8 dogs. The right femurs composed the control group, and the left femurs, the treated group, which received 2000 pulses of shock wave, with 18 kV, 5 mJ (-6dB) energy on the fracture line. Radiographs after 4, 8 and 12 weeks, revealed increased periosteal proliferation in the treated group. The results (treated/control ratio) of the scintigraphic exams, performed on weeks 2, 4, 6, 8, 10 and 12, were statistically higher for the treated group. The ESWT led to increased osteogenic activity on acute fracture's bone healing.
177

Risco de fratura radicular em pré-molar superior restaurado com pino intra-radicular: análise por elementos finitos / Risk of root fracture in upper premolars restored with an intraradicular post: finite element analysis

Santos, Andrea Fagundes Vaz dos 17 February 2009 (has links)
A restauração de dentes com grande destruição tecidual e endodonticamente tratados ainda representa um desafio para o cirurgião-dentista. A falha mais crítica após este tipo de tratamento é a fratura radicular, com maior incidência no grupo dos pré-molares superiores. O achatamento mésio-distal dos canais destes dentes e o descolamanto do pino oval têm sido apontados como os principais fatores predisponentes para este tipo de fratura. A hipótese deste trabalho é que a presença do pino aumenta o risco de fratura quando ocorre concomitantemente descolamento na interface pino/cimento. Este risco seria maior nos casos em que o pino acompanha o formato oval característico do canal do segundo pré-molar superior. O objetivo deste trabalho foi comparar, por análise de elementos finitos, as respostas de tensão máxima principal (smax) em modelos que simularam pinos de seção transversal circular ou oval, aderidos ou descolados e em modelos de dentes hígidos com canal de seção transversal circular ou oval. Foi avaliado também o risco de descolamento da interface pino/cimento. Foram construídos dois modelos 3D de segundo pré-molar superior hígido, um com canal oval (Ho) e outro com canal circular (Hc). A partir dos modelos dos dentes hígidos foram construídos modelos com pino intra-radicular de fibra de vidro e com núcleo metálico fundido. Para os casos de canais ovais (Co), os pinos poderiam apresentar seções transversais circular (Pc) ou oval (Po), enquanto para os canais circulares (Cc) foram simulados apenas pinos circulares. Todos os materiais foram considerados homogêneos, lineares e isotrópicos, com exceção do pino de fibra de vidro que foi considerado ortotrópico. Para cada modelo foi simulada uma condição de perfeita adesão (A) e outra de total descolamento (D) entre pino e cimento resinoso. Uma carga de 300 N foi aplicada a 45° na aresta central-interna da cúspide vestibular (carregamento cêntrico) ou desviada 1,4 mm para a mesial (carregamento excêntrico). Os diferentes modelos foram comparados quanto à distribuição da smax e magnitude, localização e orientação dos vetores dos picos de smax na dentina. Foi analisado também o risco de descolamento da interface pino/cimento, e os riscos de fratura do pino, núcleo e cimento. O pico de tração para os casos D foi de até 4,7 vezes maior que o encontrado nos dentes hígidos e nos casos A. Nos casos D, os pinos circulares chegam a apresentar tensão 1,7 vezes maior que os ovais. Ainda para os casos D, as raízes de seção transversal circular tiveram smax 1,3 vezes maior que as de seção transversal oval, mantendo o pino sempre circular. Já para os casos A, os valores foram muito semelhantes (embora, em geral, um pouco maiores) aos do dente hígido. O maior risco de descolamento foi detectado entre pino metálico fundido e cimento. O risco de fraturar a raiz foi maior em pinos descolados com pino metálico. Em raízes restauradas com pino de fibra, o maior risco de fratura ocorreu no núcleo e no pino, embora o valor do índice de risco de fratura seja muito mais alto que para os dentes restaurados com pino metálico. / The restoration of teeth with a large tissue destruction and endodontic treatment still presents a challenge for clinicians. The most critical failure after this type of treatment is the root fracture, with more incidence for upper premolars. The mesial-distal flattening of the root canal of these teeth and the detachment of the oval post have been pointed out as main factors predisposed to this type of fracture. The hypothesis of this study is that the presence of posts increases the risk of failure when this happens concomitantly to its detachment at the post/cement interface. This risk would be greater for cases in which the post follows the typical oval shape of the upper second premolar root canal. The objective of this study was to compare, by finite element analysis, the reply of the maximum principal stress (smax) for models which simulated posts with circular or oval cross-section, bonded or detached and for intact teeth models with circular or oval root canal. The risk of post/cement interface detachment was also evaluated. Two 3D models of an intact upper premolar, one with an oval canal (Ho) and other with a circular one (Hc) were obtained. From these models, other ones were obtained with glass fiber intra-radicular post and with cast core. For oval canals (Co), posts could presented circular (Pc) or oval (Po) crosssections, while for circular ones (Cc), only circular posts were simulated. All materials were considered homogeneous, linear and isotropic, except the glass fiber post which was considered orthotropic. For each model, a perfect bonding condition was simulated (A) and another with total detachment (D) between the post and the cement. A 300 N load was applied at 45° on the central-internal edge of the buccal cusp (centric loading) or diverted from 1,4 mm through the mesial (excentric loading). All different models were compared on stress distribution of smax and magnitude, and also smax peak vectors localization, and orientation at the dentin. The post/cement interface risk of detachment and the risk of fracture for posts, core and cement were analyzed. The tension peak for D cases was up to 4,7 times greater than that found for intact teeth and for A cases. For D cases, circular posts sometimes presented up to 1,7 times greater than oval ones. Further for D cases, roots with circular crosssectional had the smax 1,3 times greater than those with oval cross-sectional, with the post always circular. For A cases, values were however much similar (even though, in general, they were a little greater) to intact ones. The major risk of detachment was detected between the metallic post and the cement. The risk of root fracture is greater for detached posts with metallic posts. For restored roots with fiber posts, the major risk of fracture occurs to the core and the post, even the risk of fracture index is much greater than for restored teeth with metallic post.
178

INFLUÊNCIA DA ADAPTAÇÃO DE PINOS DE FIBRA E DE TÉCNICAS RESTAURADORAS ALTERNATIVAS PARA PREENCHIMENTO DE CANAIS RADICULARES EXCESSIVAMENTE ALARGADOS / Influence of fiber posts adaptation and alternative restorative techniques for flared root canal filling

Gomes, Giovana Mongruel 20 September 2013 (has links)
Made available in DSpace on 2017-07-24T19:22:29Z (GMT). No. of bitstreams: 1 Giovana Mongruel Gomes.pdf: 3752517 bytes, checksum: 6acad02e468853d81d1d9172fd003844 (MD5) Previous issue date: 2013-09-20 / The objectives of this study were 1) to evaluate the effect of the influence of the resin cement thickness (RCT) on bond strength (BS) and gap formation (GF) between glass fiber post (FP) and root dentin and 2) to evaluate the BS and fracture resistance (FR) of restorative techniques for filling oversized root canals. In experiment 1, the roots of 24 mandibular premolars (n=8 per group) were endodontically treated. After one week, the post spaces were prepared depending on the post adaptation inside the root canal, simulating an ideal adaptation (IdAd),medium adaptation (MeAd) and inadequate adaptation (InAd). All posts were cemented with Excite® DSC and Variolink® II. After a week of cementation, the RCT and GF were measured with the Image Tool software version 3.0, and the BS by the push-out test. In experiment 2, the roots of 84 mandibular premolars were endodontically treated and, after a week, the conduits were prepared in order to simulate an oversized root canal, except for the positive control group (PC), which was cemented one prefabricated fiber post (PFP) with the diameter compatible with the conduit. In the other oversized root canals, alternative restorative techniques for filling root canals were tested: NC - negative control (PFP with a smaller diameter than of the root canal), PA - PFP + accessory posts, DAP – direct anatomical post,IAP – indirect anatomical post and RR – root reinforcement with composite resin. All posts were cemented with the same adhesive system and resin cement. After indirect composite crowns cementation, the teeth were submitted to mechanical fatigue (1.2 X 106 cycles, 40 N) before the push-out BS test (n=8) and the FR test (n=6). The data of experiments 1 and 2 were analyzed by ANOVA and paired test (α=0.05). The experiment 1 showed that the smaller RCT resulted in better fiber post adhesion, that is, higher BS and lower GF. The experiment 2 showed that the use of direct and indirect anatomical posts resulted in the best performance both in BS and FR tests,and must be the first choice for FP cementation in flared roots with oversized root canals. Therefore, we concluded that the post adaptation to root canal affected significantly its retention. The better the post adaptation, the better the laboratory results. However, in the absence of this ideal condition, the use of direct and indirect anatomic posts should be the first choice for restoring flared root canals. / Os objetivos deste estudo foram 1) avaliar o efeito da influência da espessura de cimento resinoso (ECR) na resistência de união (RU) e na formação de gaps (FG) entre pino de fibra de vidro (PFV) e dentina radicular e 2) avaliar a RU e resistência à fratura (RF) de técnicas restauradoras para preenchimento de canais radiculares excessivamente alargados. No experimento 1, as raízes de 24 pré-molares inferiores (n=8 por grupo) foram tratadas endodonticamente. Após uma semana, os condutos foram preparados em função da adaptação do pino no canal radicular, simulando uma adaptação ideal (AdId), média (AdMe) e inadequada (AdIn). Todos os pinos foram cimentados com Excite® DSC e Variolink® II. Uma semana após a cimentação, a ECR e a FG foram mensuradas com o software Image Tool versão 3.0 e a RU por meio do teste de push-out. No experimento 2, as raízes de 84 pré-molares inferiores foram tratadas endodonticamente e, após uma semana, realizou-se o preparo dos condutos, de maneira a simular um canal radicular excessivamente alargado, com exceção do grupo controle positivo (GCP), em que foi cimentado um pino préfabricado (PPF) com calibre compatível ao diâmetro do conduto. Nos outros condutos alargados, técnicas restauradoras alternativas de preenchimento dos canais radiculares foram empregadas: GCN – grupo controle negativo (PPF de diâmetro inferior ao conduto), GPA – PPF + pinos acessórios, GAD – pino anatômico direto, GAI – pino anatômico indireto e GRR – reforço radicular com resina composta + PPF. Todos os pinos foram cimentados com o mesmo sistema adesivo e cimento resinoso. Após cimentação de coroas de resina indireta, os dentes foram submetidos à fadiga mecânica (1,2 x 106 ciclos, 40 N) antes de realizar o teste de RU (n=8) e de RF (n=6). Os dados do experimento 1 e 2 foram analisados por ANOVA e teste pareado (α=0,05). O experimento 1 mostrou que quanto menor a ECR melhor a adesão dos PFV, ou seja, maior a RU e menor a FG. O experimento 2 mostrou que o uso de pinos anatômicos diretos e indiretos mostrou o melhor desempenho nos testes de RU e RF, e deve ser primeira opção para cimentação de PFV em canais radiculares alargados. Portanto, foi evidenciado que a adaptação do pino ao conduto radicular influenciou significativamente na retenção dos mesmos; quanto mais justa,melhores resultados laboratoriais. Entretanto, na ausência desta condição ideal, o uso de pinos anatômicos diretos e indiretos pode ser a primeira escolha do clínico para tratamento de canais excessivamente alargados. Palavras-chave: cimentos resinosos, dentina radicular, gap, microscopia eletrônica de varredura, pinos de fibra, raízes enfraquecidas, resistência à fratura, resistência de união.
179

EFEITO DA APLICAÇÃO SÔNICA DE SISTEMAS ADESIVOS NA ADESÃO DE PINOS DE FIBRA DE VIDRO NO CANAL RADICULAR / EFFECTS OF SONIC APPLICATION OF ADHESIVE SYSTEMS ON BONDING FIBER POSTS TO ROOT CANALS

Sánchez, Johanna Lizbeth Cuadros 26 February 2014 (has links)
Made available in DSpace on 2017-07-24T19:22:33Z (GMT). No. of bitstreams: 1 Johanna Lizbeth Cuadros Sanchez.pdf: 3888267 bytes, checksum: abbdebf22c3a3a8b49c91f6bc734b34d (MD5) Previous issue date: 2014-02-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Abstract: Luting of posts inside the root canal is still a challenge because of the difficult to bonding mainly in the apical third. The aim of this study was evaluate the influence of the application of 3 simplified total-etch adhesive systems (Adper Single Bond 2 Ambar, and XP-Bond+self-cure activator) under manual mode or sonic vibration on the push-out bond strength (POBS), silver nitrate uptake (SNU) and in situ degree of conversion (ISDC) associated to resin cement when used for luted posts. Methods: The roots of 66 human premolars were prepared and divided into six groups (n=11), according to the following combination: adhesive and application mode. The posts were cemented in accordance with the manufacturer’s instructions of each cementation system. After water storage, the roots were sectioned transversely into six slabs and it were tested in POBS (0.5mm/min). Two roots for group were data were immersed in 50% silver nitrate, photo-developed and analyzed by SEM to measure the SNU. Two roots for group were evaluated by micro-Raman spectroscopy to measure ISDC. The data were analyzed by 3-way repeated measures ANOVA and Tukey's tests (5%). Results: When sonic application was performed, usually there are a significantly increasing on the POBS (MPa) (35% and 37% respectively) and ISDC (%) (14% and 38% respectively in the medium and apical thirds) and decreasing of SNU (%) for all groups mainly in the medium (64% decreasing) and apical (84%) thirds when compared with manually application (P < 0.05). / Resumo: A cimentação de pinos dentro do canal radicular ainda é um desafio por causa das dificuldades relativas à adesão, principalmente no terço apical. O objetivo deste estudo foi avaliar a influência da aplicação de três sistemas adesivos convencionais simplificados (Adper Single Bond 2, Ambar e XP-Bond + self cure ativator) manualmente ou através de um dispositivo sônico vibratório na resistência de união por push-out (RU), na infiltração de nitrato de prata (NI) e no grau de conversão in situ (GC) associado ao cimento resinoso de cada fabricante, quando utilizado para cimentação de pinos. Métodos: As raízes de 66 pré-molares humanos foram preparadas e divididas em seis grupos (n = 11), de acordo com a seguinte combinação: adesivo/cimento e modo de aplicação. Os pinos foram cimentados de acordo com as instruções do fabricante de cada sistema de cimentação apenas variando o modo de aplicação. Depois do armazenamento em água, as raízes foram seccionadas transversalmente em seis fatias e foram testados em RU (0,5 mm/min). Duas raízes por grupo foram imersas em 50% de nitrato de prata, e após revelação, foram analisadas por MEV para medir a NI. Duas raízes por grupo foram avaliadas por espectroscopia de micro-Raman para medir GC. Os dados foram analisados por análise de variância de 3 fatores de medidas repetidas (terço radicular) e teste de Tukey (5%). Resultados: Quando a aplicação sônica vibratória foi utilizada, em geral, se observou um aumento significativo na RU (MPa) (35% e 37% respectivamente) e GC (%) (14% e 38% respectivamente nos terços médio e apical) e diminuição da NI (%) para todos os grupos, principalmente nos terços médio (redução de 64%) e apicais (84%) quando comparada com a aplicação manual (p <0,05) e este fenômeno ocorreu para todos os sistemas adesivos/cimentos testados.
180

Influência de técnica restauradora alternativa com diferentes tipos de resina composta para reforço radicular em raízes enfraquecidas / Influence of alternative restorative technique with different types of composite resin for root reinforcement in weakened roots

Chidoski Filho , Julio Cezar 21 February 2018 (has links)
Submitted by Eunice Novais (enovais@uepg.br) on 2018-07-31T14:08:13Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Julio Cezar C Filho.pdf: 2297707 bytes, checksum: 0318db2af277ea89875b724010007eb0 (MD5) / Made available in DSpace on 2018-07-31T14:08:13Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Julio Cezar C Filho.pdf: 2297707 bytes, checksum: 0318db2af277ea89875b724010007eb0 (MD5) Previous issue date: 2018-02-21 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Avaliou-se a influência do tipo e viscosidade da resina composta utilizada para reforço radicular (RR) em dentes com canais radiculares excessivamente alargados na adesão de pinos de fibra de vidro (PFV) ao canal radicular. Foram selecionados 78 dentes permanentes unirradiculares, os quais tiveram suas coroas removidas e suas raízes tratadas endodonticamente. Após uma semana, foi realizado o preparo dos condutos para posterior RR. Nesse momento, as raízes foram aletoriamente divididas em 6 grupos (n=13), sendo um grupo controle positivo (GCP – em que os canais não estavam alargados), um grupo controle negativo (GCN – em que os canais estavam alargados, porém sem RR), e 4 grupos de RR dos canais alargados de acordo com a combinação dos seguintes fatores: tipo de resina composta: bulk ou convencional e viscosidade da resina composta: fluida ou regular. Após a cimentação dos PFV, para cada raiz foram obtidas seis fatias (duas representativas de cada região radicular - terço coronário, médio e apical). Em seguida, para cada grupo, 7 raízes foram avaliados em resistência de união (RU) pelo teste de push-out, 6 raízes foram avaliados em nanoinfiltração (NI) e microdureza Vickers. Os dados obtidos de RU e NI foram submetidos a ANOVA dois fatores (grupo experimental vs região radicular) e Tukey (α=0,05), e de microdureza a ANOVA um fator e Tukey para cada grupo experimental (α= 0,05). Os grupos de RR com as resinas tipo bulk em ambas as viscosidades apresentaram resultados de adesão superiores estatisticamente ao GCN em todas as regiões radiculares (maior RU e menor NI). Pode-se concluir que a técnica de reforço radicular com resinas composta do tipo bulk, tanto com viscosidade regular quanto com viscosidade fluida, pode ser uma técnica alternativa interessante previamente à cimentação de PFV em raízes enfraquecidas com canais radiculares alargados. / The influence of the type and viscosity of the composite resin used for root reinforcement (RR) was evaluated in teeth with excessively wide root canals in the adhesion of glass fiber post (GFP) to the root canal. It was selected 78 uniradicular permanent teeth, which had their crowns removed and their roots treated endodontically. After one week, the conduits were prepared for later RR. At that time, the roots were randomly divided into 6 groups (n = 13): positive control group (PCG - where the root canals were not enlarged), negative control group (NCG - where the root canals were widened - but without RR), and 4 groups of RR of the widened root canals according to the combination of the following factors: type of composite resin: bulk or conventional and viscosity of composite resin: flow or regular. After the cementation of the GFP, six slices were obtained for each root (two representatives of each root region - coronary, middle and apical third). Then, for each group, 7 teeth were evaluated in bond strength (BS) by the push-out test, 6 teeth were evaluated in nanoleakage (NL) and Vickers microhardness (VHN). The data obtained from BS and NL were submitted to two-way ANOVA (experimental group vs root region) and Tukey (α = 0.05), and from VHN to one-way ANOVA and Tukey for each experimental group (α = 0.05). The RR groups with bulk composite resins at both viscosities showed statistically superior adhesion results to GCN in all root regions (higher BS and lower NL). It can be concluded that the radicular reinforcement technique with bulk composite resins, both with regular and flow viscosities, may be an interesting alternative technique prior to the GFP cementation in weakened roots with widened root canals.

Page generated in 0.1182 seconds