• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 178
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 185
  • 102
  • 72
  • 65
  • 49
  • 49
  • 48
  • 47
  • 47
  • 45
  • 45
  • 42
  • 42
  • 41
  • 39
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Avaliação clínica do uso de pinos de fibra de carbono na restauração de dentes tratados endodonticamente: um estudo retrospectivo

Coppo, Priscilla Pessin 16 April 2010 (has links)
Made available in DSpace on 2018-08-01T23:26:07Z (GMT). No. of bitstreams: 1 tese_4200_Dissertação Priscilla Coppo.pdf: 1792164 bytes, checksum: a5582e0f738e32fbe27c3261e5994d2d (MD5) Previous issue date: 2010-04-16 / Os estudos clínicos de dentes desvitalizados e restaurados com pinos mostram resultados semelhantes no que diz respeito ao percentual de falhas ou insucessos, apesar de tantas variações técnicas, metodológicas e operatórias entre eles. Os insucessos são maiores quando se tratam de elementos dentais coronariamente destruídos ou comprometidos periapicalmente. Com o objetivo de identificar o efeito das variações clínicas que influenciam na longevidade do tratamento e a prevalência de descimentação de pinos, cárie marginal, fraturas radiculares e de lesões periapicais, foi realizada uma análise retrospectiva do desempenho clínico de dentes restaurados com pino de fibra de carbono. Foram avaliados 139 dentes em 75 pacientes, três anos após a data de cimentação dos pinos. Os dentes foram submetidos a tratamentos endodônticos, incluindo preparos dos condutos para pino, e tratamentos restauradores, realizados pelo mesmo endodontista e protesista, respectivamente, segundo protocolos padronizados. Através de exame clínico, radiográfico, fotográfico, laudos endodônticos e informações obtidas de prontuários, os dentes foram classificados de acordo com: grupos dentais, modalidade de tratamento endodôntico recebida, intervalo decorrido entre a última sessão endodôntica e a cimentação do pino, morfologia do pino, quantidade de remanescente dentinário coronário após preparo protético e sistema da coroa protética utilizado. Não foram constatadas descimentações de pinos, fraturas radiculares, ou cáries, e a classificação foi favorável para 99,3% (138 dentes) dos tratamentos endodônticos realizados. De acordo com os parâmetros analisados, os resultados desse estudo revelaram que as variações clínicas identificadas, consideradas desfavoráveis, não foram fatores determinantes para o insucesso, partindo-se do conjunto de procedimentos e materiais utilizados para o tratamento dos dentes desses pacientes. / Clinical studies of devitalized teeth restored with posts show similar outcomes with regard to the percentage of faults or failures, despite many technical variations, methodological and operative between them. The failures are greater when dealing with teeth coronally destroyed or periapically compromised. The aim of this study was identify the effect of clinical variants that influence the longevity of treatment and prevalence of dislodgment of post, marginal caries, root fracture and periapical lesions was performed a retrospective analysis of clinical performance of teeth restored with carbon fiber post. 139 teeth were evaluated in 75 patients, three years after the date of cementing the posts. The teeth were root canal treatments, including preparations of the conduits to posts, and restorative treatments, performed by the same endodontist and prosthetics, respectively, according to standardized protocols. Through clinical, radiographic, photographic, endodontic reports and information obtained from medical records, the teeth were classified according to: tooth groups, type of endodontic treatment received, time span between the last endodontic session and bonded post, morphology of the post, amount of remaining dentin after crown preparation and prosthetic crown system used. There were no dislodgment of post, root fractures, or caries, and the rank was favorably for 99.3% (138 teeth) of endodontic treatment. According to these parameters, the outcomes of this study revealed that the clinical variations identified, that are considered unfavourable, were not determining for the failure, starting from the set of procedures and materials used for dental treatment of these patients.
122

Influência do cimento endodôntico e agente cimentante na retenção de pinos de fibra / Influence of endodontic sealer and luting cements on fiber posts bond strength

Nascimento, Angela Longo do January 2015 (has links)
Objetivos: O objetivo desse estudo foi avaliar a influência da presença do cimento endodôntico e agente cimentante na retenção de pinos de fibra. Metodologia: Cento e oitenta dentes extraídos foram divididos em dois grupos (n=90) de acordo com a forma de obturação: condensação lateral ou obturação apenas do terço apical. Cada um destes grupos foi subdividido em três grupos (n=10) de acordo com o cimento utilizado para a obturação (AH Plus, Endofil e MTAFillapex). Os cimentos foram manipulados e acrescidos de corante Rodamina B na proporção de 0,1% para possibilitar visualização através da microscopia confocal a laser. Quinze dias após a obturação, estes dentes foram preparados para a cimentação do pino de fibra (Reforpost Angelus) com os cimentos RelyX ARC (ARC), U200 e Gold Label Cement Lining (GL). Os dentes foram seccionados transversalmente para obtenção de fatias com 1mm de espessura e submetidos à microscopia confocal a laser para verificar a penetração do cimento endodôntico nos túbulos dentinários, posteriormente ao teste de push-out. O padrão de falha foi analisado em esteromicroscópio e imagens representativas foram feitas em microscopia eletrônica de varredura. Os valores de resistência de união em MPa de acordo com a técnica de obturação foram analisados pelo teste de Mann-Whitney. Os valores de resistência de união dos grupos experimentais foram analisados pelo teste de Kruskal-Wallis e post hoc de Dunn, com nível de significância de 5%. Resultados: Não houve diferença significativa entre as formas de obturação (P>0,05). O tipo de cimento obturador influenciou a resistência de união, e o cimento MTA-Fillapex apresentou valores de resistência de união significativamente inferiores ao AH Plus (P<0,05). Os grupos que utilizaram GL para cimentação dos pinos de fibra de vidro apresentaram valores para o teste de push-out superiores aos cimentos resinosos (P < 0,05). Não houve diferença significativa entre o ARC e o U200 (P > 0,05). Conclusões: Valores de resistência de união mais altos foram observados quando os pinos de fibra foram cimentados com cimento GL . Os padrões de falha mistas foram predominantes e ocorreram em todos os grupos experimentais. / Aim: Evaluate the influence of the endodontic sealer and luting cements on the fiber post bond strength. Methodology: One hundred and eighty extracted teeth were assigned to two groups, considering the root filling technique: lateral condensation or root filling of the apical portion only. Each group were divided into three groups (n=10) according the sealer applied (AH Plus, Endofill or MTA-Fillapex). Rhodamine B was mixed to the sealer in a ratio of 0,1% in order to provide adequate fluorescence assessed by confocal microscopy. Fifty days after root canal filling, post-space preparation were performed with luting cements: RelyX ARC (ARC), U200 and Gold Label Cement Lining (GL). One thick slices were produced and submitted to confocal miscroscopy to assessed sealer penetration into dentinal tubules, and than submitted to push-out test. The failure modes were analysed in stereomicroscope and representative images were obtained in a scanning electron microscope. Push-out strength values of the root filling technique were analyzed using Mann-Whitney test. Push-out strength values of experimental groups were analysed using Kruskal-Wallis and Dunn´s post hoc test at significance level 5%. Results: No significant difference was observed (P>0.05) between the root filling technique. The type of endodontic sealer influenced the push-out bond strength, and MTA-Fillapex sealers presents lower bond strength values than AH Plus (P<0.05). Fiber posts cemented with GL presented higher push-out bond strength than resin cements (P<0.05). There was no significant difference between ARC and U200 (P>0.05). Conclusions: Fiber posts showed higher bond strength values when cemented with GL. Mixed failures were predominant and occurred in all the experimental groups.
123

Avaliação por microdureza Vickers da profundidade de polimerização de cimentos resinosos na cimentação de pinos de fibra de vidro empregando diferentes fontes de luz /

Conti, Elaine Cristina Guerbach. January 2006 (has links)
Orientador: José Roberto Cury Saad / Banca: Patrícia dos Santos Jardim / Banca: Luiz Alberto Plácido Penna / Banca: Osmir Batista de Oliveira Júnior / Banca: Marcelo Ferrarezi de Andrade / Resumo: O objetivo desse estudo foi avaliar a microdureza Vickers de um cimento resinoso químico (C&B Cement - Bisco) e um de ativação dual (RelyX ARC - 3M ESPE), fotopolimerizado por diferentes fontes de luz, em função de diferentes profundidades do canal radicular, na cimentação de pinos de fibra de vidro. Os aparelhos fotopolimerizadores empregados foram: Optilux 360 (Demetron) - luz halógena; Radii (SDI) - LED; UltraLume 5 (Ultradent) - LED. Nenhuma diferença estatisticamente significante foi observada nos valores de microdureza Vickers, dos terços cervical, médio e apical do canal radicular, para o cimento resinoso químico (G1), e os terços cervicais do cimento resinoso dual, para todos os aparelhos fotopolimerizadores (G2, G3 e G4) (p>0.05). Porém, o aparelho de luz halógena (G2) e o LED UltraLume 5 (G4) apresentaram comportamentos semelhantes, proporcionando uma diminuição gradativa nos valores médios de microdureza do cimento resinoso dual, do terço cervical para o apical (p<0.001). Os menores valores de microdureza foram encontrados nos terços apical do sistema RelyX ARC fotopolimerizado com luz halógena ou com LED UltraLume 5. / Abstract: This study evaluated the Vickers microhardness of a chemically cured resin cement (C&B Cement - Bisco) and a dual cure cement (RelyX ARC - 3M ESPE), light cured by different light sources, according to the different root canal depths, for luting of glass fiber posts. The light curing units employed were Optilux 360 (Demetron) - halogen lamp; Radii (SDI) - LED; UltraLume 5 (Ultradent) - LED. No statistically significant difference was observed in Vickers microhardness values at the cervical, middle and apical root thirds for the chemically cured resin cement (G1), and at the cervical third for the dual resin cement, for all light curing units (G2, G3 and G4) (p>0.05). However, the halogen lamp unit (G2) and LED UltraLume 5 (G4) presented similar performance, providing gradual reduction in mean microhardness values for the dual resin cement from the cervical to the apical third (p<0.001). The lowest microhardness values were found at the apical third for the system RelyX ARC light cured with halogen lamp or LED UltraLume 5. / Doutor
124

Avaliação das propriedades mecânicas e químicas em função de diferentes cimentos resinosos e pinos não-metálicos /

Bandéca, Matheus Coelho. January 2009 (has links)
Resumo: Este estudo objetivou: (1) testar a hipótese que a utilização de pinos nãometálicos em dentes tratados endodonticamente está associado a longevidade da restauração através de uma revisão sistemática; (2) avaliar o grau de conversão de dois cimentos resinosos em diferentes tempos após a fotoativação; (3) avaliar a resistência adesiva de diferentes cimentos resinosos usando dois pinos não-metálicos; (4) e avaliar a resistência a fratura e padrão de falha de dentes submetidos ao clareamento dental interno usando peróxido de hidrogênio a 35% restaurados com diferentes procedimentos. No artigo 1, 157 artigos participaram do estudo e após os critérios de inclusão-exclusão, restaram apenas 5 artigos. Para o artigo 2, vinte espécimes foram confeccionados para cada cimento, Panavia® F2.0 e RelyXTM Unicem Applicap. Cada espécime foi curado com luz LED e foram analisados imediatamente, 24 horas, 48 horas e 7 dias após a fotoativação. Os testes usados foram grau de conversão (FT-IR) e termogravimetria. No artigo 3, oitenta dentes pré-molares unirradiculares livres de coroas foram usados e divididos em 8 grupos: os pinos Exacto! e Everstick! foram cimentados com Breeze!, Nexus! 3, Panavia! e Bistite!. Os dentes foram obturados e preparados para cimentação dos pinos não-metálicos. Cada espécime foi perpendicularmente seccionado em aproximadamente 1 mm de espessura em 6 discos e divididos em região ! cervical, médio e apical. No artigo 4, oitenta dentes incisivos inferiores foram usados e metade foram clareados. Os dentes foram restaurados com resina composta, pinos de resina reforçado com fibra e pinos de fibra de vidro. Os pinos foram cimentados com Breeze! e Panavia!. Os espécimes foram submetidos ao teste de resistência a fratura pela máquina de testes universal. Todos os dados foram submetidos ao devido tratamento estatístico. Os pinos usados... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study aimed: (1) To test the hypothesis that the placement of nonmetallic post in endodontically treated teeth is associated with improved survival rate of the restored teeth althouth systematic review; (2) to evaluate the degree of conversion of two resin cements in differents times after light-activated; (3) to evaluate the microtensile bond strength of different resin cement systems using two nonmetallic posts; (4) to evaluate the fracture resistance and failure pattern of endodontically treated teeth after intracoronal bleaching using 35% hydrogen peroxide with different restorative procedures. For the article 1, 157 papers were used and after the inclusion-exclusion procedure, only 5 papers remained. For the article 2, twenty specimens were made for each cement, Panavia® F2.0 and RelyXTM Unicem Applicap. Each specimen were cured with LED and were tested immediately, 24 hours, 48 hours and 7 days after light-activated. The tests used were degree of conversion (FT-IR) and thermogravimetric. For the article 3, eighty single-rooted human mandibular first premolar free crown were used and divided into 8 groups: Exacto! and Everstick! posts were cemented with Breeze!, Nexus! 3, Panavia! F 2.0 and Bistite! II DC. The teeth were obtured and prepared for cementation of the nonmetallic posts. Each specimen were perpendicularly sectioned into approximately 1 mm thick sections resulting in 6 serial slices and divided in cervical, meddium and apical region. For the !article 4, eighty mandibular incisors were used and the half teeth were bleached. The teeth were restored with composite resin, fiber-reinforced composite post and glass fiber post. The posts were cemented with Breeze! and Panavia!. The specimens were submitted to the fracture resistance test by universal test machine. Statistical analyses were performed for each article. The posts used... (Complete abstract click electronic access below) / Orientador: Sizenando de Toledo Porto Neto / Coorientador: Omar El-Mowafy / Coorientador: Alessandra Nara de Souza Rastelli / Banca: Roberto Cury Saad / Banca: Darlon Martins Lima / Mestre
125

Influência do cimento endodôntico e agente cimentante na retenção de pinos de fibra / Influence of endodontic sealer and luting cements on fiber posts bond strength

Nascimento, Angela Longo do January 2015 (has links)
Objetivos: O objetivo desse estudo foi avaliar a influência da presença do cimento endodôntico e agente cimentante na retenção de pinos de fibra. Metodologia: Cento e oitenta dentes extraídos foram divididos em dois grupos (n=90) de acordo com a forma de obturação: condensação lateral ou obturação apenas do terço apical. Cada um destes grupos foi subdividido em três grupos (n=10) de acordo com o cimento utilizado para a obturação (AH Plus, Endofil e MTAFillapex). Os cimentos foram manipulados e acrescidos de corante Rodamina B na proporção de 0,1% para possibilitar visualização através da microscopia confocal a laser. Quinze dias após a obturação, estes dentes foram preparados para a cimentação do pino de fibra (Reforpost Angelus) com os cimentos RelyX ARC (ARC), U200 e Gold Label Cement Lining (GL). Os dentes foram seccionados transversalmente para obtenção de fatias com 1mm de espessura e submetidos à microscopia confocal a laser para verificar a penetração do cimento endodôntico nos túbulos dentinários, posteriormente ao teste de push-out. O padrão de falha foi analisado em esteromicroscópio e imagens representativas foram feitas em microscopia eletrônica de varredura. Os valores de resistência de união em MPa de acordo com a técnica de obturação foram analisados pelo teste de Mann-Whitney. Os valores de resistência de união dos grupos experimentais foram analisados pelo teste de Kruskal-Wallis e post hoc de Dunn, com nível de significância de 5%. Resultados: Não houve diferença significativa entre as formas de obturação (P>0,05). O tipo de cimento obturador influenciou a resistência de união, e o cimento MTA-Fillapex apresentou valores de resistência de união significativamente inferiores ao AH Plus (P<0,05). Os grupos que utilizaram GL para cimentação dos pinos de fibra de vidro apresentaram valores para o teste de push-out superiores aos cimentos resinosos (P < 0,05). Não houve diferença significativa entre o ARC e o U200 (P > 0,05). Conclusões: Valores de resistência de união mais altos foram observados quando os pinos de fibra foram cimentados com cimento GL . Os padrões de falha mistas foram predominantes e ocorreram em todos os grupos experimentais. / Aim: Evaluate the influence of the endodontic sealer and luting cements on the fiber post bond strength. Methodology: One hundred and eighty extracted teeth were assigned to two groups, considering the root filling technique: lateral condensation or root filling of the apical portion only. Each group were divided into three groups (n=10) according the sealer applied (AH Plus, Endofill or MTA-Fillapex). Rhodamine B was mixed to the sealer in a ratio of 0,1% in order to provide adequate fluorescence assessed by confocal microscopy. Fifty days after root canal filling, post-space preparation were performed with luting cements: RelyX ARC (ARC), U200 and Gold Label Cement Lining (GL). One thick slices were produced and submitted to confocal miscroscopy to assessed sealer penetration into dentinal tubules, and than submitted to push-out test. The failure modes were analysed in stereomicroscope and representative images were obtained in a scanning electron microscope. Push-out strength values of the root filling technique were analyzed using Mann-Whitney test. Push-out strength values of experimental groups were analysed using Kruskal-Wallis and Dunn´s post hoc test at significance level 5%. Results: No significant difference was observed (P>0.05) between the root filling technique. The type of endodontic sealer influenced the push-out bond strength, and MTA-Fillapex sealers presents lower bond strength values than AH Plus (P<0.05). Fiber posts cemented with GL presented higher push-out bond strength than resin cements (P<0.05). There was no significant difference between ARC and U200 (P>0.05). Conclusions: Fiber posts showed higher bond strength values when cemented with GL. Mixed failures were predominant and occurred in all the experimental groups.
126

Proposta de método de ensaio para a determinação da resistência da madeira ao embutimento / Proposed test method for determining of the embedment strength of wood

Diego Henrique de Almeida 30 June 2014 (has links)
Os pontos com maior fragilidade em estruturas de madeira são as ligações, pois nelas ocorrem as maiores concentrações de tensões. Dentre os tipos de conectores mais utilizados nas ligações temos os pinos metálicos, no quais se enquadra o parafuso comum. Para o dimensionamento de ligações por pinos metálicos, dois parâmetros são utilizados: a resistência ao escoamento do aço e a resistência da madeira ao embutimento. O objetivo deste trabalho foi comparar os métodos de ensaio de documentos normativos (ABNT NBR 7190:1997, EN 383:2007, ASTM D5764:2007, EUROCODE 5:2004, NDS:2001 e LRFD:1996) com a finalidade de estabelecer uma proposta de método de ensaio para a determinação da resistência da madeira ao embutimento. Foram realizados ensaios na direção paralela e na direção normal às fibras para seis espécies de madeira (Paricá, Pinus elliottii, Pinus oocarpa, Jatobá, Lyptus e Cupiúba), utilizando vários diâmetros (8 mm, 10 mm, 12 mm e 16 mm) para os pinos metálicos. Baseado na análise dos resultados obtidos foi proposta a adoção do método de ensaio baseado na EN 383:2007. Os resultados experimentais para a resistência ao embutimento tem maior aprovação com o parâmetro resistência à compressão paralela às fibras, atualmente adotado pela ABNT NBR 7190:1997. Além disso, esse método recomenda dimensões que facilitam a confecção dos corpos de prova, principalmente na direção normal às fibras. / Main fragility in timber structures occurs in the connections, because to stress concentrations. Most of connections use bolts laterally loaded, a metal dowel-type fastener. Two parameters are used for design of the connections with metal dowel-type in timber structures: yield strength of metal dowel and embedment strength of wood. The aim of this study was to compare the test methods of Codes (ABNT NBR 7190:1997, EN 383:2007, ASTM D5764:2007, EUROCODE 5:2004, NDS:2001 and LRFD:1996) in order to establish a proposed test method for the determination of the embedment strength of wood. The tests were performed applying load in the direction parallel and in the direction perpendicular to the grain for six species of wood (Paricá, Pinus elliottii, Pinus oocarpa, Jatobá, Lyptus and Cupiúba) using several diameters (8 mm, 10 mm, 12 mm and 16 mm) for the metal dowels. Based on the analysis of the results, is proposed adopting the test method based on EN 383:2007. The experimental results for the embedment strength has better fit with the strength parameter currently used by ABNT NBR 7190:1997, compression parallel to the grain. In addition, this method recommends dimensions that facilitate the specimens preparation, mainly in the direction perpendicular to the grain.
127

Influência do cimento endodôntico e agente cimentante na retenção de pinos de fibra / Influence of endodontic sealer and luting cements on fiber posts bond strength

Nascimento, Angela Longo do January 2015 (has links)
Objetivos: O objetivo desse estudo foi avaliar a influência da presença do cimento endodôntico e agente cimentante na retenção de pinos de fibra. Metodologia: Cento e oitenta dentes extraídos foram divididos em dois grupos (n=90) de acordo com a forma de obturação: condensação lateral ou obturação apenas do terço apical. Cada um destes grupos foi subdividido em três grupos (n=10) de acordo com o cimento utilizado para a obturação (AH Plus, Endofil e MTAFillapex). Os cimentos foram manipulados e acrescidos de corante Rodamina B na proporção de 0,1% para possibilitar visualização através da microscopia confocal a laser. Quinze dias após a obturação, estes dentes foram preparados para a cimentação do pino de fibra (Reforpost Angelus) com os cimentos RelyX ARC (ARC), U200 e Gold Label Cement Lining (GL). Os dentes foram seccionados transversalmente para obtenção de fatias com 1mm de espessura e submetidos à microscopia confocal a laser para verificar a penetração do cimento endodôntico nos túbulos dentinários, posteriormente ao teste de push-out. O padrão de falha foi analisado em esteromicroscópio e imagens representativas foram feitas em microscopia eletrônica de varredura. Os valores de resistência de união em MPa de acordo com a técnica de obturação foram analisados pelo teste de Mann-Whitney. Os valores de resistência de união dos grupos experimentais foram analisados pelo teste de Kruskal-Wallis e post hoc de Dunn, com nível de significância de 5%. Resultados: Não houve diferença significativa entre as formas de obturação (P>0,05). O tipo de cimento obturador influenciou a resistência de união, e o cimento MTA-Fillapex apresentou valores de resistência de união significativamente inferiores ao AH Plus (P<0,05). Os grupos que utilizaram GL para cimentação dos pinos de fibra de vidro apresentaram valores para o teste de push-out superiores aos cimentos resinosos (P < 0,05). Não houve diferença significativa entre o ARC e o U200 (P > 0,05). Conclusões: Valores de resistência de união mais altos foram observados quando os pinos de fibra foram cimentados com cimento GL . Os padrões de falha mistas foram predominantes e ocorreram em todos os grupos experimentais. / Aim: Evaluate the influence of the endodontic sealer and luting cements on the fiber post bond strength. Methodology: One hundred and eighty extracted teeth were assigned to two groups, considering the root filling technique: lateral condensation or root filling of the apical portion only. Each group were divided into three groups (n=10) according the sealer applied (AH Plus, Endofill or MTA-Fillapex). Rhodamine B was mixed to the sealer in a ratio of 0,1% in order to provide adequate fluorescence assessed by confocal microscopy. Fifty days after root canal filling, post-space preparation were performed with luting cements: RelyX ARC (ARC), U200 and Gold Label Cement Lining (GL). One thick slices were produced and submitted to confocal miscroscopy to assessed sealer penetration into dentinal tubules, and than submitted to push-out test. The failure modes were analysed in stereomicroscope and representative images were obtained in a scanning electron microscope. Push-out strength values of the root filling technique were analyzed using Mann-Whitney test. Push-out strength values of experimental groups were analysed using Kruskal-Wallis and Dunn´s post hoc test at significance level 5%. Results: No significant difference was observed (P>0.05) between the root filling technique. The type of endodontic sealer influenced the push-out bond strength, and MTA-Fillapex sealers presents lower bond strength values than AH Plus (P<0.05). Fiber posts cemented with GL presented higher push-out bond strength than resin cements (P<0.05). There was no significant difference between ARC and U200 (P>0.05). Conclusions: Fiber posts showed higher bond strength values when cemented with GL. Mixed failures were predominant and occurred in all the experimental groups.
128

Avaliação clínica do uso de pinos de fibra de carbono na restauração de dentes tratados endodonticamente: um estudo retrospectivo

Coppo, Priscilla Pessin 16 April 2010 (has links)
Made available in DSpace on 2018-08-01T23:26:07Z (GMT). No. of bitstreams: 1 tese_4200_Dissertação Priscilla Coppo.pdf: 1792164 bytes, checksum: a5582e0f738e32fbe27c3261e5994d2d (MD5) Previous issue date: 2010-04-16 / Os estudos clínicos de dentes desvitalizados e restaurados com pinos mostram resultados semelhantes no que diz respeito ao percentual de falhas ou insucessos, apesar de tantas variações técnicas, metodológicas e operatórias entre eles. Os insucessos são maiores quando se tratam de elementos dentais coronariamente destruídos ou comprometidos periapicalmente. Com o objetivo de identificar o efeito das variações clínicas que influenciam na longevidade do tratamento e a prevalência de descimentação de pinos, cárie marginal, fraturas radiculares e de lesões periapicais, foi realizada uma análise retrospectiva do desempenho clínico de dentes restaurados com pino de fibra de carbono. Foram avaliados 139 dentes em 75 pacientes, três anos após a data de cimentação dos pinos. Os dentes foram submetidos a tratamentos endodônticos, incluindo preparos dos condutos para pino, e tratamentos restauradores, realizados pelo mesmo endodontista e protesista, respectivamente, segundo protocolos padronizados. Através de exame clínico, radiográfico, fotográfico, laudos endodônticos e informações obtidas de prontuários, os dentes foram classificados de acordo com: grupos dentais, modalidade de tratamento endodôntico recebida, intervalo decorrido entre a última sessão endodôntica e a cimentação do pino, morfologia do pino, quantidade de remanescente dentinário coronário após preparo protético e sistema da coroa protética utilizado. Não foram constatadas descimentações de pinos, fraturas radiculares, ou cáries, e a classificação foi favorável para 99,3% (138 dentes) dos tratamentos endodônticos realizados. De acordo com os parâmetros analisados, os resultados desse estudo revelaram que as variações clínicas identificadas, consideradas desfavoráveis, não foram fatores determinantes para o insucesso, partindo-se do conjunto de procedimentos e materiais utilizados para o tratamento dos dentes desses pacientes. / Clinical studies of devitalized teeth restored with posts show similar outcomes with regard to the percentage of faults or failures, despite many technical variations, methodological and operative between them. The failures are greater when dealing with teeth coronally destroyed or periapically compromised. The aim of this study was identify the effect of clinical variants that influence the longevity of treatment and prevalence of dislodgment of post, marginal caries, root fracture and periapical lesions was performed a retrospective analysis of clinical performance of teeth restored with carbon fiber post. 139 teeth were evaluated in 75 patients, three years after the date of cementing the posts. The teeth were root canal treatments, including preparations of the conduits to posts, and restorative treatments, performed by the same endodontist and prosthetics, respectively, according to standardized protocols. Through clinical, radiographic, photographic, endodontic reports and information obtained from medical records, the teeth were classified according to: tooth groups, type of endodontic treatment received, time span between the last endodontic session and bonded post, morphology of the post, amount of remaining dentin after crown preparation and prosthetic crown system used. There were no dislodgment of post, root fractures, or caries, and the rank was favorably for 99.3% (138 teeth) of endodontic treatment. According to these parameters, the outcomes of this study revealed that the clinical variations identified, that are considered unfavourable, were not determining for the failure, starting from the set of procedures and materials used for dental treatment of these patients.
129

Análise tridimensional pelo método de elementos finitos do comportamentto biomecânico do incisivo central superior hígido e restaurado com coroa cerâmica utilizando diferentes retentores intra-radiculares / Three-dimensional finite element analyses of biomechanical behavior in a maxillary incisor with all-ceramic crow using different posts

João Paulo Filgueiras Ribeiro 11 February 2009 (has links)
O objetivo do estudo foi analisar tridimensionalmente, por meio do Método de Elementos Finitos (MEF), o comportamento biomecânico de um incisivo central superior hígido sob condição de oclusão fisiológica e posteriormente comparar com diferentes simulações de situações clínicas de dentes tratados endodonticamente e restaurados com coroas totais cerâmicas, variando a quantidade de remanescente dental e o tipo de retentor intra-radicular (núcleo metálico fundido- NMF, fibras de vidro- RFV e zircônio- RZ). Foram construídos modelos tridimensionais do incisivo central superior sem e com 2 mm de remanescente dentinário na porção coronária. Uma carga de 10 N foi aplicada de forma normal no terço incisal, nas cristas marginais mesial e distal, da superfície palatal. A análise dos dados foi realizada pelo programa computacional NeiNastran® - Noran Engineering, Inc. Os resultados de deslocamento e tensão máxima principal foram obtidos mostrando que houve diferenças significativas na distribuição de tensão entre o dente hígido e o com retentor intra-radicular. O grupo com NMF apresentou o comportamento mais similar ao dente hígido (controle), seguidos do retentor de fibra de vidro com remanescente e sem remanescente dental. Os grupos que apresentaram maior diferença em relação ao controle foram os retentores de zircônia sem e com remanescente de dentina. Considerando- se a presença de remanescente dentinário na porção coronária (2mm) para os grupos restaurados com retentores pré- fabricados, os RFV apresentaram uma redução do estresse na interface dente/restauração em comparação com RZ. Pode-se concluir que a utilização de núcleos metálicos fundidos apresentou comportamento biomecânico mais similar ao dente hígido. / The purpose of this study was to evaluated by three-dimensional finite element analysis the biomechanical behavior of a healthy maxillary central incisor under physiological load comparing with different clinical conditions of endodontically treated teeth restored with all-ceramic crowns, with various remaining tooth structure and post-and-core systems (cast metal post- MP, glass fiber post- GFP and zirconium post- ZP). Three-dimensional models were performed with and without 2 mm of dental remaining in coronary portion. A load of 10 N was applied in normal way at the incisal third of the palatine surface in the mesial and distal marginalis ridges. Data analysis was performed by the computer program NeiNastran ® - Noran Engineering, Inc. The results of maximal stress and displacement demonstrated significant differences in the tensile distribution in healthy (control) and restored tooth. The MP showed similar performance in comparison with healthy tooth, followed by GFP with and without remaining tooth structure. The teeth restored with ZP showed higher difference than control group. This study demonstrated that presence of the coronary remaining dentin (2mm) decreases the stress concentration at the interface crown/restoration using GFP in comparison with ZP. Conclusion that cast metal post can reduce the stress level in maxillary central incisor and showed biomechanical behavior similar than healthy teeth.
130

Resistência da união da cimentação adesiva de pinos de fibra de vidro frente ao teste de remoção por extrusão / Push-out bond strength of adhesive luted glass fiber posts

Luciana Mendonça da Silva 24 March 2009 (has links)
Este trabalho avaliou a resistência de união de pinos de fibra de vidro cimentados à dentina com o uso de um cimento resinoso convencional e um auto-adesivo. Trinta dentes bovinos unirradiculares tiveram as raízes 17mm a partir dos ápices. As raizes foram tratadas endodonticamente e divididas aleatoriamente em 3 grupos (n=10): G1- cimento resinoso convencional RelyX ARC + ScotchBond Multi Uso Plus (SBMP) fotoativado + pino de fibra de vidro; G2 RelyX ARC + SBMP quimicamente ativado + pino de fibra de vidro; G3 cimento resinoso auto-adesivo RelyX U100 + pino de fibra de vidro. Após a cimentação dos pinos, os espécimes foram armazenados por 24 horas em água destilada, à 37oC. As raízes foram cortadas sob irrigação constante para obter de 6 a 9 fatias de 1mm de espessura. O teste de resistência à extrusão foi realizado para medir a resistência adesiva nas fatias da região cervical, média e apical, a uma velocidade de 0,5mm/min. Todos os espécimes foram observados em microscópio ótico de luz para avaliar os tipos de falhas. Os valores foram submetidos à análise de variância a dois critérios (ANOVA) e teste de Tukey (p0,05). As médias gerais dos grupos 1, 2 e 3, respectivamente, (MPa) foram de 4,87 (±3,65); 5,89(±3,72); e 8,50(±4,52). Os valores de resistência adesiva regional nos terços cervical, médio e radicular, respectivamente, foram: G1- 5,26(±3,44); 5,11(±3,33); 5,01(±3,17); G2- 7,45(±3,82); 5,88(±2,50); 4,91(±2,74); G3- 10,11(±3,11); 9,12(±3,70); 4,99(±3,28). Os maiores valores de resistência adesiva foram encontrados com o cimento auto-adesivo. Ao avaliar os terços separadamente, os grupos 2 e 3 obtiveram comportamento semelhante nos terços cervical e médio. No terço apical, todos os grupos tiveram o mesmo comportamento. A resistência de união foi influenciada pelo tipo de cimento utilizado e região radicular, mas não foi alterada pela variação do modo de polimerização do sistema adesivo. / This work evaluated the bond strength of glass fiber posts to dentin using a conventional and a self-adhesive resin cement. Thirty bovine incisors had their roots sectioned 17mm from their apices, endodontically treated and assigned into 3 groups (n=10): group 1, conventional resin cement RelyX ARC + ScotchBond Multi Purpose Plus (SBMP) light activated + glass fiber post; Group 2, RelyX ARC+ SBMP chemically activated + glass fiber post; Group 3, self-adhesive resin cement RelyX U100 + glass fiber post. After luting, specimens were stored for 24 hours in distilled water at 37oC. Roots were sliced under water irrigation to obtain 1mm thick slices. Push-out test was performed on each slice with a universal testing machine with a crosshead speed of 0,5mm/min. All fractured specimens were observed using a light microscope to identify modes of failure. Values were submitted to two-way ANOVA and Tukeys test (p0,05). Mean values (MPa) and standard deviation for groups 1, 2 and 3 were, respectively: 4.87 (±3.65); 5.89(±3.72); e 8.50(±4.52). Regional bond strength values for the cervical, medium and apical were: G1- 5.26(±3.44); 5.11(±3.33); 5.01(±3.17); G2- 7.45(±3.82); 5.88(±2.50); 4.91(±2.74); G3- 10.11(±3.11); 9.12(±3.70); 4.99(±3.28). The highest bond strength values were obtained using the self-adhesive cement. Regional bond strengths were similar in the cervical and medium region in groups 2 and 3. All cements had the same performance on the apical region. Bond strength was influenced by the type of cement used and radicular region, but was not altered by the activation mode of the bonding system.

Page generated in 0.0704 seconds