• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 15
  • 1
  • Tagged with
  • 16
  • 16
  • 9
  • 8
  • 8
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • 4
  • 4
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação do efeito pró-oxidante no PP, em blendas com PHB, visando a biodegradação / Evanluation of the effect of pro-degrading addtives in PP, blended with PHB aiming at biodegradation

Santos, Paulo Aparecido dos, 1958- 19 August 2018 (has links)
Orientador: Marco-Aurelio De Paoli / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-19T12:36:34Z (GMT). No. of bitstreams: 1 Santos_PauloAparecidodos_D.pdf: 4409534 bytes, checksum: 96efe381105ce71c4086f51f5599d6ce (MD5) Previous issue date: 2011 / Resumo: O interesse por polímeros biodegradáveis tem aumentado muito devido ao baixo impacto ambiental dos mesmos. No entanto os polímeros biodegradáveis disponíveis no mercado são frágeis, difíceis de processar e tem alto custo. Uma das técnicas para superar essas deficiências é através de blenda com outros polímeros. Este trabalho avaliou várias composições de blenda PHB / PP, utilizando-se um aditivo pró-degradante deste último, de forma a tornar a formulação oxibiodegradável em solo simulado (ASTM D6003). O comportamento mecânico, térmico e químico de corpos de prova de tração foram analisados através de medidas de resistência à tração, DSC, FTIR, GPC e MEV. Parte das amostras foi envelhecida em estufa a 90 ºC por 10 dias, de forma a acelerar a oxidação do PP pelo aditivo. A blenda composta por 56wt% de PP / 40wt% de PHB / 3wt% de GMA / 1wt% de MnSt foi a mais susceptível à oxibiodegradação, tendo reduzido, depois de 180 dias de enterramento em solo, a tensão de tração por 40%, alongamento na ruptura por 46% e a massa em 24%. Estes valores foram superiores ao próprio PHB puro e o efeito sinérgico ocorrido nestas blendas foi atribuído à aceleração da degradação do PHB pelo PP oxidado / Abstract: The interest in the use of biodegradable polymers has increased recently because of their environmental advantages. Blending them with other polymers is one of the techniques currently employed to overcome their brittleness, poor processing and cost. This work evaluated different blend compositions of PHB / PP, using a pro-degrading additive for this latter, to make the formulation prone to oxi-biodegradability in simulated soil (ASTM D6003). The mechanical and chemical behavior of buried injection molded tensile bars were analyzed through measurements of tensile strength, DSC, FTIR, GPC and SEM. Part of the samples were oven aged at 90 ºC for 10 days in order to accelerate the PP oxidation by the additive. Blends made from 56wt% of PP / 40wt% of PHB / 3wt% of GMA / 1wt% of MnSt were the most susceptible to oxi-biodegradation, having reduced after 180 days of burring in soil, its tensile stress by 40%, tensile elongation by 46% and weight by 24%. These values were higher even than for the pure PHB. This synergic effect on this blend was attributed to a high degradation of PP, which for its turn, facilitated PHB biodegradation / Doutorado / Quimica Inorganica / Doutor em Ciências
12

Influência da incorporação de poli(ácido lático) - PLA, de pó de madeira e outros aditivos no comportamento físico-mecânico do poli(hidroxibutirato) - PHB. / Influence of incorporation of poly(lactic acid) - PLA, of wood power and other additives over the physicalmechanical behaviour of poly(hydroxybutirate) - PHB.

Falcone, Daniele Maria Bruno 30 April 2004 (has links)
Made available in DSpace on 2016-06-02T19:11:56Z (GMT). No. of bitstreams: 1 338.pdf: 8743393 bytes, checksum: 5bbce617a1f060ab7e7fb0f2a22a5829 (MD5) Previous issue date: 2004-04-30 / Financiadora de Estudos e Projetos / Polymeric materials are used today in the most varied sectors and the deleterious effects of their application, particularly in the short-term, have led to increasing environmental concern. On the other hand, innovative biodegradable polymers, which promise to offset these effects, are still hampered by their high cost and often unsatisfactory performance. In view of this fact, a study was made of poly(hydroxybutyrate)/poly(lactic acid) - PHB/PLA; poly(hydroxybutyrate)/wood powder-PHB/WP; and PHB/other modifiers (starch, rice chaff, sugarcane bagasse fiber) blends and compounds. These blends and compounds were evaluated and characterized using the following techniques: Melt Flow Index (MFI), Capillary Rheometry, Torque Rheometry, Differential Scanning Calorimetry (DSC), Thermogravimetry (TG), Dynamic Mechanical Thermal Analysis (DMTA), Physical and Mechanical Tensile and Impact tests, Heat Deflection Temperature (HDT) tests, and Scanning Electron Microscopy (SEM). The results obtained indicated the immiscibility of the PHB/PLA blends. The absence of transesterification reactions in the PHB/PLA blends was verified by TG. From the standpoint of mechanical properties, the PHB/PLA blends generally displayed characteristics superior to those of pure polymers. On the other hand, the polymeric compounds containing wood powder displayed rigidity and greater brittleness due to the lack of adhesion between the wood powder and the polymer, as indicated by SEM. This study therefore indicated that it is possible to obtain materials with adequate physical and mechanical characteristics that are viable particularly for short-term applications. / Atualmente os materiais poliméricos se destacam nos mais variados setores. Por outro lado, principalmente as suas aplicações de curto-prazo estão provocando uma crescente preocupação com o meio-ambiente. Neste contexto, surgem os polímeros biodegradáveis. Entretanto, os polímeros biodegradáveis não se apresentam competitivos, pois ainda têm um custo elevado e nem sempre fornecem um desempenho satisfatório. Diante desta situação, fez-se um estudo sobre as blendas e compostos: poli(hidroxibutirato)/poli(ácido lático) PHB/PLA; poli(hidroxibutirato)/pó de madeira PHB/PM; poli(hidroxibutirato)/poli(ácido lático)/pó de madeira PHB/PLA/PM; PHB/outros modificadores (amido, palha de arroz, fibra de bagaço de cana de açúcar). As blendas e os compostos foram avaliados/caracterizados por: Índice de Fluidez (MFI), Reometria Capilar, Reometria de Torque, Calorimetria Exploratória Diferencial (DSC), Termogravimetria (TG), Análise Térmica Dinâmico-mecânica (DMTA), Ensaios físico-mecânicos de tração, de impacto e de Temperatura de distorção ao calor (HDT), e por Microscopia Eletrônica de Varredura (MEV). Os resultados obtidos através das diversas técnicas, indicaram a imiscibilidade das blendas PHB/PLA. A ausência de reações de transesterificação para as blendas PHB/PLA foi verificada pela TG. Em termos de propriedades mecânicas, as blendas PHB/PLA de um modo geral apresentaram características melhores em relação aos polímeros puros. Já os compostos poliméricos contendo pó de madeira mostraram rigidez e um comportamento mais frágil, devido a ausência de adesão entre o pó de madeira e o polímero, conforme verificado por MEV. Assim, com este estudo, verificou-se a possibilidade de obter materiais com características físico-mecânicas adequadas e que sejam viáveis, especialmente nas aplicações de curto-prazo.
13

Films de PLA y PLA-PHB plastificados para su aplicación en envases de alimentos. Caracterización y análisis de los procesos de degradación

Arrieta, Marina Patricia 03 September 2014 (has links)
El uso de envases plásticos, constituidos por materiales poliméricos derivados del petróleo, se ha extendido en muchas aplicaciones debido a su disponibilidad a gran escala, bajo coste de producción, gran versatilidad y buenas propiedades barrera. Sin embargo, representan un importante impacto medioambiental y una fuente enorme de generación de residuos de difícil eliminación. Como respuesta a este problema se ha planteado la prevención de la contaminación ambiental mediante el uso de biopolímeros como el poli(ácido láctico), PLA. Tras el uso de estos productos, el PLA puede ser recuperado a través de procesos mecánicos (triturado-transformación térmica) o químicos (hidrólisis), o bien ser depositado junto con la materia orgánica para la formación de compost. Además de los estudios intensivos de la biodegradabilidad del PLA en condiciones de compostaje, la estabilidad térmica y el comportamiento durante la degradación térmica cobran importancia para la transformación, aplicación, y el reciclado térmico. La aplicación de la tecnología de pirólisis al tratamiento de residuos ha ganado aceptación en la industria. La pirólisis de residuos de PLA puede ser económica y medioambientalmente atractiva. Para estudiar los cambios estructurales de los materiales, la pirólisis es una técnica analítica mucho más sensible que las técnicas térmicas analíticas utilizadas comúnmente como termogravimetría (TGA), o calorimetría diferencial de barrido (DSC). La combinación de la pirólisis acoplada a cromatografía de gases y con el espectrómetro de masas (Py-GC-MS), resulta una herramienta ventajosa para la caracterización de polímeros. La pirolisis produce compuestos volátiles los cuales pueden ser identificados y también cuantificados. De esta manera, la Py-GC-MS resulta una técnica analítica muy útil para obtener información sobre las reacciones química de degradación de los polímeros inducidas por la temperatura, puede proporcionar información de la cinética de descomposición de los polímeros y de la composición de los productos obtenidos de la degradación térmica. El PLA es un bipoliéster obtenido de la polimerización del ácido láctico. Es un polímero termoplástico biodegradable, que puede obtenerse a partir de productos agrícolas simples como el maíz. En la actualidad el PLA se encuentra disponible en el mercado en aplicaciones prácticas como cubiertos, platos, tazas, tapas, bolsas, films, y aplicaciones de envasado de alimentos. El PLA ha cobrado especial interés debido su disponibilidad en el mercado, bajo coste, y su potencial para reemplazar a otros polímeros derivados del petróleo, como poliestireno o polietilentereftalato, utilizados en el envasado de alimentos. El PLA se reconoce como seguro en aplicaciones de envasado de alimentos, clasificado como GRAS (Generally Recognized As Safe) por la FDA. El uso de PLA se encuentra limitado debido a que presenta algunas restricciones en cuanto a sus propiedades barrera, mecánicas, y térmicas. En este sentido, la alta fragilidad del PLA limita tanto su capacidad de proceso como sus aplicaciones y una manera de mejorar el comportamiento mecánico del PLA es mediante la adición de plastificantes. No obstante, la adición de plastificante como modificadores del PLA se encuentra limitada por los requisitos de su aplicación final. Así, para el envasado de alimentos sólo se pueden añadir plastificantes no tóxicos y aprovados para el contacto con alimentos. Para modificar al PLA también se ha estudiado la mezcla con otros polimeros, en este sentido el Polihidroxibutirato (PHB), es capaz de aumentar la cristalinidad del PLA. El PHB es un polímero biodegradable, biocompatible, de regular cristalinidad y moderada resistencia mecánica, utilizado en varias aplicaciones, como por ejemplo, en la fabricación de envases plásticos biodegradables. Al obtenerse a partir de fuentes de carbono naturales renovables, como maíz representa un material biodegradable prometedor para reemplazar otros polímeros sintéticos. / Arrieta, MP. (2014). Films de PLA y PLA-PHB plastificados para su aplicación en envases de alimentos. Caracterización y análisis de los procesos de degradación [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/39338 / Premios Extraordinarios de tesis doctorales
14

Avaliação in vitro de polímeros de PHBV, PCL e blendas (75/25 e 50/50) para engenharia de tecidos ósseos

Silva, Amália Baptista Machado January 2014 (has links)
Orientador: Prof. Dr. Arnaldo Rodrigues dos Santos Junior / Dissertação (mestrado) - Universidade Federal do ABC, Programa de Pós-Graduação em Biotecnociência, 2014. / Na engenharia de tecidos, a utilização de uma fonte de celular juntamente com um biomaterial, representa uma alternativa clínica a ser aplicada a pacientes com graves lesões no tecido ósseo. Este estudo teve como objetivo avaliar células Vero, uma linhagem de célula fibroblásticas, e uma linhagem de células-tronco mesenquimais (Rat (SD) Mesenchymal Stem Cells) em testes de biocompatibilidade in vitro com polímeros de poli(hidroxibutirato-co-hidroxivalerato) (PHBV), poli(caprolactona) (PCL) e blendas 75/25 e 50/50 desenvolvidos para a bioengenharia de tecido ósseo. A diferenciação osteogênica das CTMs sobre os polímeros também foi analisada. Os biomateriais foram caracterizados morfologicamente através de Microscopia Eletrônica de Varredura (MEV), Estereoscópio e Micrômetro. Polímeros porosos se mostram mais espesso que os densos. Através das imagens obtidas nota-se a distribuição, tamanho e morfologia dos poros, notando que os polímeros se mostram com características condizentes a de outros trabalhos. As células Vero e células-tronco mesenquimais (CTMs) foram cultivadas sobre as amostras citadas. Realizamos o ensaio com o MTT, análise morfológica e citoquímica. Para as CTMs fizemos ainda ensaios para avaliar a diferenciação osteogênica (fosfatase alcalina e vermelho alizarina). Nenhum dos polímeros foi considerado tóxico para as células Vero e na maioria deles foi notada atividade celular, camadas de células bem distribuídas. As blendas 50/50 mostraram resultados um pouco inferiores, quanto ao MTT, essa blenda porosa demonstrou ser a uma amostra onde adesão ocorre de forma bem mais lenta, os demais polímeros apresentaram resultados semelhantes e até superiores ao controle positivo de adesão, principalmente o PCL denso. Apesar das amostras 50/50 densa e porosa não se mostrarem tóxicas, aparentemente não funcionam com bons substratos como os demais polímeros, também apresentaram várias dificuldades na técnica de preparação, sendo assim descartadas. A relação das CTMs com os biomateriais se mostrou semelhante aos resultados com Vero. As células foram capazes de se espalhar por quase toda a superfície dos polímeros inclusive entre os poros dos materiais porosos. As CTMs apresentaram resultados de adesão (MTT) sobre os polímeros, mais rápido do que a Vero, demonstrando também maior afinidade pelo PCL denso. Através da análise da atividade da enzima fosfatase alcalina (usada como marcador de diferenciação), notamos que as células-tronco se mostraram capazes de se diferenciar em contato com os polímeros. Esses dados foram confirmados com o vermelho de alizarina, que também mostrou que a diferenciação celular se mostra um pouco mais lenta nos materiais do que nas placas. De uma forma geral os polímeros com exceção das blendas 50/50 se mostraram como bons substratos para as células, com ausência de toxicidade, características morfológicas dentro do recomendado e, além disso, não bloqueiam respostas biológicas específicas, como a diferenciação osteogênica. / In tissue engineering, the use of a cell source coupled with biomaterial represents a clinical alternative which can be applied to patients with severe bone damage. This study aimed to evaluate the biocompatibility between Vero a fibroblastic cell line and Mesenquymal stem cells (Rat (SD) MSC) with biomaterials developed as scaffolds for bone tissue engineering, bioresorbable polymers composed of poly ( hydroxybutyrate-co-hydroxyvalerate ) [ PHVB ] and poly ( caprolactone ) [ PCL ] pure and ratios of (75 /25) and (50 /50) blends. The osteogenic differentiation of MSCs on the polymers was also analyzed. Morphological characterization of the materials was performed by Scanning Electron Microscopy (SEM), Stereoscope and micrometer. The porous polymers are thicker than dense. Through the images obtained it is possible to note distribution, morphology and pore size. The biomaterials seem to the same consistent characteristics of other studies. Vero cells and mesenchymal stem cells (MSCs) were cultured on the samples mentioned. We performed the assay with MTT, morphological and histochemical analysis. About MSCs we also evaluated the osteogenic differentiation (alkaline phosphatase and Alizarin red). None of the polymers was considered toxic to Vero cells and most of them presented cellular activity, layers of well-distributed cells was noted in most of them. However 50/50 blends showed no such significant results as other. In the MTT assay, this porous blend demonstrated to be the only sample where adhesion occurs more slowly, other polymers showed similar and even higher results than the adhesion positive control, especially the dense PCL. Although the dense and porous 50/50 samples do not show toxic, apparently they are not good substrates as the other polymers, also presented several difficulties in their preparation thus being discarded. The ratio of MSCs with biomaterials was similar to the Vero cells results. They were able to spread to almost all surface of the polymers including into the pores of porous materials. MSCs showed adhesion (MTT) faster than the Vero cell, also demonstrated a greater affinity for dense PCL sample. Through analysis of the enzyme alkaline phosphatase activity (used as a marker for differentiation), we noticed that the stem cells showed differentiation into contact with the polymers. These data were confirmed by alizarin red, which also showed that the cell differentiation was slower on the materials than on the plates. In general all the polymer blends but the 50/50 proved to be good substrates for cells, with no toxicity, morphological characteristics within recommended and in addition do not block specific biological responses, such as osteogenic differentiation.
15

Comportamento de celulas osteoblasticas sobre biomateriais polimericos / Osteoblast cells behavior on polymeric biomaterial

Lucchesi, Carolina 02 August 2010 (has links)
Orientadores: Paulo Pinto Joazeiro, Eliana Aparecida de Rezende Duek / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Biologia / Made available in DSpace on 2018-08-15T19:20:15Z (GMT). No. of bitstreams: 1 Lucchesi_Carolina_D.pdf: 5696358 bytes, checksum: 89bc8546c0a1d6b5a11d7260168dd236 (MD5) Previous issue date: 2010 / Resumo: Os polímeros biorreabsorvíveis, tais como, PHB, PCL e PLGA, têm sido estudados como dispositivo para engenharia de tecidos por serem biocompatíveis, suportarem o crescimento e diferenciação celular e os produtos de sua degradação serem atóxicos. No entanto, a escolha do biomaterial depende das necessidades exigidas para uma determinada aplicação. Os suportes para engenharia de tecidos devem se basear na construção de réplicas biológicas in vitro, como que o biomaterial se tornasse parte integrada para transplante in vivo para a recuperação de perdas ou mau funcionamento de tecidos ou órgãos, devendo subseqüentemente, atuar sem agredir o restante do organismo, isto é, sem o risco de rejeição ou complicação. Muitas estratégias têm sido desenvolvidas com o intuito de substituir tecidos ou órgãos danificados, incluindo a aplicação de suportes tridimensionais (3D), os quais devem possuir características estruturais e mecânicas para guiar a proliferação e espalhamento de células in vitro e in vivo. Os suportes, feitos de materiais sintéticos ou naturais, servem como substitutos para a matriz extracelular (MEC) nativa. Ênfase especial é dada as técnicas com controle computadorizado, como a fabricação sólida com forma livre (SFF), conhecida como prototipagem rápida (RP), a qual permite preparar suportes 3D com geometrias complexas, tanto externamente como internamente, além de ser uma técnica rápida e de baixo custo. Além disso, grande parte dos polímeros possuem superfície hidrofóbica, característica inadequada para a maior parte dos diferentes tipos celulares, o que dificulta aplicação na engenharia de tecidos. Uma alternativa a este problema é o tratamento da superfície por plasma. Este tratamento induz modificação restrita ao topo da superfície, conferindo carater hidrofílico à superfície, dependendo do gás utilizado. Neste estudo, arcabouços de polímeros biorreabsorvíveis PCL, PLGA e PHB foram preparados por diferentes técnicas, casting e sinterização seletiva a laser, avaliando-se o comportamento de células osteoblásticas diferenciadas sobre os biomateriais poliméricos tridimensionais. Inicialmente o trabalho foi desenvolvido com os polímeros PCL e PLGA preparando-se blendas poliméricas, as quais demonstraram melhorar as características gerais dos polímeros, quando utilizados como dispositivos para tecido ósseo, como as propriedades mecânicas. Com o intuito de aprimorar o design tridimensional do material, optou-se pela realização da técnica de sinterização seletiva a laser. No entanto, a técnica exige uma grande quantidade de material e devido ao alto do custo do PCL e PLGA, este foi substituído pelo polímero PHB, o qual é produzido pela indústria nacional Biocycle possuindo um baixo custo e ainda ser biocompatível. Os dados são apresentados em capítulos independentes. Arcabouços porosos de PCL, PLGA e suas blendas foram preparados pela técnica de evaporação do solvente, onde sais de citrato de sódio com granulometria de 180-250 µm, foram adicionados a solução para a promoção dos poros, sendo posteriormente lavados do arcabouço. Células osteoblásticas provenientes de calota craniana de ratos Wistar foram semeadas sobre os arcabouços, sendo avaliado o comportamento de citoxicidade do material e o comportamento de adesão e morfologia celular através de ensaios bioquímicos e MEV. Os arcabouços de PHB foram obtidos por uma das técnicas de RP, a sinterização seletiva a laser (SSL), sendo sua superfície modificada por plasma pelos gases oxigênio e nitrogênio. Células osteoblásticas provenientes de calota craniana de coelhos foram semeadas sobre os arcabouços realizando-se o estudo in vitro, através de análises bioquímicas pela técnica do MTT, para viabilidade e adesão celular, quantificação de colágeno por Sírius Red e Microscopia Eletrônica de Varredura (MEV). Para o estudo in vivo, após o cultivo celular sobre os arcabouços, defeitos ósseos foram provocados em coelhos e os arcabouços contendo as células foram então implantados, avaliando-se a interação PHB/osteoblasto/tecido, através da análise histológica. Todos os arcabouços estudados, PCL, PLGA e suas blendas, assim como o PHB, não apresentaram índices de citotoxicidade, permitiram às células a capacidade de adesão, proliferação e síntese de matriz, mantendo seu fenótipo osteoblástico. As amostras de PHB tratadas por plasma de Nitrogênio mostrou melhorar a capacidade de adesão celular. Os arcabouços de PHB contendo células mostraram-se os mais adequados para o preenchimento de defeitos ósseos, melhorando o processo de regeneração apresentando uma boa osteointegração. A sinterização seletiva a laser apresentou-se uma excelente técnica para a obtenção de PHB 3D para a Engenharia de Tecidos. / Abstract: The bioresorbable polymers as, PHB, PCL and PLGA have been studied as device for Tissue Engineering for their biocompatibility and to support the cell growth and differentiation and their degradation products are nontoxics. However, the choice of the biomaterial depends on the needs demanded for a certain application. The scaffolds for tissue engineering have to be designed to mimetize the biological conditions in vitro to became part integrated for transplant for the recovery of tissue or organs lost or without function, and subsequently, to work in a cordial way with the remaining of the organism without the rejection risk or complication. A lot of strategies have been developed with to substitute damaged tissues or organs, and it has been used the application of three-dimensional supports (3D), which should possess structural and mechanical applications to guide the cells proliferation and spread in vitro and in vivo. The scaffolds, made from synthetic or natural materials, serve as substitutes for the extracellular matrix (ECM) native. Special emphasis is given the techniques with computerized control, as the free solid form (SFF), known as rapid prototyping (RP), which allows to prepare three-dimensional supports with complex geometries, so much externally as internally, besides to be a fast technique with low cost. Besides, great part of the polymers possess hydrophobic surface, inadequate characteristic for most of the different cell types, which is not desirable for tissue engineering applications. An alternative to this problem is the surface treatment by plasma. Plasma treatment induces restricted modification to the top of the surface, improving the surface hydrophilicity, depending on the gas used. In this study, scaffolds of bioresorbable polymer PCL, PLGA e PHB were prepared by different techniques, casting and selective laser sintering, being evaluated the osteoblast cells behavior on the 3D polymer scaffolds. Previously we developed the studies preparing the polymeric blends with PCL and PLGA, which demonstrated improve the general characteristic of the material, as the mechanical properties, as devices for bone tissue. With the intention to improve the design of the scaffolds, we chose for the selective laser sintering technique. However, the technique demands a great amount of material and due to the high cost of PCL and PLGA, those weres substituted by PHB polymer, which is produced by Brazilian industry Biocycle with low cost and still to be biocompatible. For those reasons the data are presented in independent chapters. PCL, PLGA porous scaffolds and their blends were prepared those scaffolds by casting solvent, and sodium citrate with 180-250 µm were added to the solution for porous formation when the salt was washed later of the scaffolds. Osteoblast cells from rat Wistar calvaria were seemed on the scaffolds, being evaluated the behavior of cell adhesion and viability behavior, cell morphology through biochemical assays, and scanning electron microscopy. Three-dimensional PHB scaffolds were obtained by selective sintering laser (SSL), with the surface modified by nitrogen and oxygen plasma. Osteoblast cells obtained from rabbit calvaria were seemed on the scaffolds to the in vitro studies, through biochemical analyses by MTT test for cell viability and cell adhesion, collagen quantification of by Sirius Red colorimetric assay and scanning electron microscopy (SEM). For the in vivo studies, bone defects were provoked in rabbits and they were filling out with 3D PHB with osteoblast cells culture prior implant. We evaluated the PHB/osteoblast/tissue, interaction through the histological analysis. All the scaffolds studied PCL, PLGA and their blends, as well as the PHB did not showed cytotoxicity effects, allowed cells adhere, proliferated, and matrix synthesized, maintaining their osteoblastic phenotype. The PHB samples treated by nitrogen plasma have been showed to improve the cell adhesion. The PHB scaffolds with cell seeded previously demonstrated to be more suitable for filling out bone defects, improving the regeneration process showing a good osteointegration. The selective laser sintering was excellent technique to obtain PHB scaffolds for Tissue Engineering. / Doutorado / Biologia Celular / Doutor em Biologia Celular e Estrutural
16

Arcabouços 3D (Scaffolds) à base de poli (hidroxibutirato), quitosana e fibroína da seda para engenharia tecidual / 3D scaffolds based on poly (hydroxibutirate), chitosan and silk fibroin for tissue engineering

Macedo, Maria Erisfagna Ribeiro de 02 March 2017 (has links)
Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Materials based on polyhydroxybutyrate (PHB), chitosan (CHI) and fibroin (SF) are biocompatible and attractive for applications in bone tissue engineering. In this work, 3D scaffolds of PHB/CHI and PHB/CHI/SF in different proportions was prepared, characterized and evaluated the in vitro behavior: group I: PHB/CHI (50:50 wt.%), group II: PHB/CHI/SF (50:45:5 wt.%) and group III: PHB/CHI/SF (50:35:15 wt.%). The scaffolds were produced by the lyophilization method of the components mixtures. The physical-chemical characterization of the scaffolds was performed by X-ray diffraction, infrared spectroscopy, scanning electron microscopy and thermogravimetric analysis. A highly porous nature was revealed by SEM analysis of the scaffolds. The FTIR analysis revealed that the constituents used in the preparation of the scaffolds interacted chemically with each other. Thermal analysis showed that fibroin increases the thermal stability of the scaffolds. The viability and cell proliferation were assessed by the MTT method and the cytotoxicity results showed that all scaffolds are non- cytotoxic. In addition, the scaffolds stimulated cell proliferation and are promising for tissue engineering applications. / Materiais à base de polihidroxibutirato (PHB), quitosana (QUI) e fibroína (SF) são biocompatíveis e atrativos para aplicações na engenharia tecidual óssea. Neste trabalho foi preparado, caracterizado e avaliado o comportamento in vitro de arcabouços 3D de PHB/QUI/SF em diferentes proporções: grupo I: PHB/QUI (50:50 % em massa), grupo II-PHB/QUI/SF (50:45:5 % em massa) e grupo III- PHB/QUI/SF (50: 35:15 % em massa). Os arcabouços foram produzidos pelo método da liofilização das misturas dos componentes dos três grupos. A caracterização físico-química dos arcabouços foi realizada por difração de raios X, espectroscopia no infravermelho, microscopia eletrônica de varredura e análise termogravimétrica. A análise de MEV mostrou que os arcabouços 3D apresentam uma boa porosidade. Por FTIR observou- se que os componentes utilizados na preparação dos arcabouços interagiram quimicamente entre si. As análises térmicas indicam que a fibroína aumenta a estabilidade térmica dos arcabouços. A viabilidade e a proliferação celular foram avaliadas pelo método do MTT e os resultados de citotoxicidade mostraram que ambos os arcabouços não são citotóxicos. Além disso, os arcabouços estimularam a proliferação celular, sendo promissores para aplicações em engenharia tecidual.

Page generated in 0.054 seconds