• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 29
  • 2
  • Tagged with
  • 31
  • 22
  • 22
  • 20
  • 17
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

PotÃncia e liberdade na Ãtica de Benedictus de Spinoza

Carlos Wagner Benevides Gomes 31 January 2017 (has links)
CoordenaÃÃo de AperfeÃoamento de Pessoal de NÃvel Superior / Esta pesquisa tem como objetivo explicitar, a partir da anÃlise da Ãtica e das demais obras do filÃsofo holandÃs Benedictus de Spinoza (1632-1677), como o Breve Tratado, o Tratado da Reforma da InteligÃncia e os tratados polÃticos, a problemÃtica da PotÃncia (potentia) e da Liberdade (libertas) humana. Primeiramente, partiremos dos fundamentos ontolÃgicos da Ãtica, a saber, a teoria da SubstÃncia, dos seus atributos e dos seus modos (corpo e mente), alÃm disso, a questÃo do conhecimento e do mÃtodo filosÃfico. Por conseguinte, explicitaremos a questÃo da potÃncia presente na Parte III (A origem e a Natureza dos Afetos) da Ãtica e nos escritos polÃticos onde Spinoza discute o esforÃo (conatus) ou a potÃncia humana para agir e pensar ante as paixÃes negativas e tudo aquilo que impossibilita uma vida livre da ignorÃncia e da servidÃo. Ao analisar os afetos e as paixÃes, Spinoza demonstra a relaÃÃo intrÃnseca entre PotÃncia e Liberdade, pois esta à o exercÃcio ou a realizaÃÃo da potÃncia segundo a qual o homem tem para tornar-se livre. Assim, discutiremos como podemos entender a potÃncia como uma realizaÃÃo necessÃria para o homem tornar-se livre. Por sua vez, o problema da liberdade serà tratado pela anÃlise da Parte I (De Deus) e V (Da PotÃncia do intelecto ou da Liberdade Humana) da Ãtica de Spinoza. Ou seja, apresentaremos, primeiramente, como o filÃsofo holandÃs colocou a liberdade no seu ponto de vista ontolÃgico, ou seja, onde Deus, cuja potÃncia à infinita e necessÃria, seria o Ãnico denominado coisa livre e no seu ponto de vista Ãtico e polÃtico segundo o qual os homens sÃo modos finitos (corpo e mente) de Deus e potÃncias individuais (direito natural) e coletivas (direito civil) determinados como parte do todo e sujeitos à servidÃo das paixÃes. Neste sentido, tentaremos responder como à possÃvel que o homem, que nÃo nasce livre, torna-se livre mesmo diante de suas condiÃÃes como modo da SubstÃncia (Deus). Por conseguinte, apresentaremos de que forma esta liberdade se torna polÃtica enquanto Direito civil ou PotÃncia da multidÃo (multitudinis potentiae) e esforÃa-se para garantir uma liberdade de expressÃo e de opiniÃo. Conclui-se que, recorreremos à questÃo da potÃncia humana, que conduzida pela razÃo, à capaz de refrear certas paixÃes e compreender, adequadamente, as causas que nos aproximam da liberdade.
2

Conversor CA/CC com capacitor chaveado para LEDs de potÃncia / Converter AC/DC with Switched-Capacitor for power LEDs

Pedro Henrique Almeida Miranda 03 August 2012 (has links)
FundaÃÃo Cearense de Apoio ao Desenvolvimento Cientifico e TecnolÃgico / Este trabalho propÃe um conversor com capacitor chaveado para o acionamento de LEDS (Light Emitting Diodes) de potÃncia. Em contraste com circuitos de acionamento convencionais de corrente contÃnua, o pulso de corrente direcionado para os LEDs, à limitado pela potÃncia armazenada no capacitor chaveado. Neste circuito, o capacitor à carregado e descarregado atravÃs do circuito de saÃda e a direÃÃo do fluxo de corrente à controlada pelos interruptores. Baseado na anÃlise do controle de carga, os efeitos do comutaÃÃo no conversor proposto sÃo discriminados e avaliados. Os resultados experimentais demonstram a viabilidade tÃcnica de utilizar o conversor proposto para LEDs. / This paper proposes a switched-capacitor converter to drive power light emitting diodes (LEDs). In contrast to conventional constant dc current drivers, the current pulse is provided by this switched-capacitor LED driver. In the present driver, the capacitor is charged and discharged through of the output circuit and the current flow direction is controlled by switch. Based on the charge control analysis, the effects of switching devices on the proposed converter are discriminated and evaluated. The experimental results demonstrated the technical feasibility of using the proposed converter for LEDs.
3

Conversor CC/CC de alto ganho sem capacitor eletrolÃtico aplicado a um sistema fotovoltaico / High gain DC/DC converter without electrolytic capacitor applied to photovoltaic systems

AntÃnio Alisson Alencar Freitas 14 December 2012 (has links)
CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / O setor fotovoltaico, devido ao seu grande crescimento nos Ãltimos anos, vem destacando-se significativamente diante de todas as outras fontes de energia renovÃveis e, por isso, tornou-se a terceira maior fonte limpa de geraÃÃo de energia elÃtrica do mundo. No Brasil, esse setor ainda nÃo possui uma relevÃncia na matriz energÃtica devido à tecnologia de conversores e de painÃis ser, na maioria das vezes, toda importada. Considerando a necessidade do desenvolvimento dessa tecnologia, este trabalho vem propor a pesquisa e a implementaÃÃo de um conversor CC/CC de alto ganho aplicado a sistemas fotovoltaicos, que tem como objetivo principal retirar a energia de um mÃdulo fotovoltaico e injetÃ-la em um barramento constante de corrente contÃnua. Um mÃdulo fotovoltaico à conectado na entrada do conversor de alto ganho com tensÃo de saÃda igual a 17 Vcc. Esse conversor eleva a sua tensÃo de entrada e injeta sua corrente de saÃda em um barramento constante de 311 Vcc, utilizando a busca do ponto de mÃxima potÃncia (MPPT). O protÃtipo implementado em laboratÃrio foi desenvolvido para uma potÃncia nominal de 100 W e nÃo possui capacitores eletrolÃticos, aumentando assim o tempo de vida Ãtil do conversor e permitindo incorporar o conversor ao mÃdulo fotovoltaico. O protÃtipo se mostrou robusto e de baixo custo, caracterÃsticas necessÃrias para um conversor aplicado a fontes renovÃveis de energia. O desempenho do protÃtipo, na busca do ponto de mÃxima potÃncia, superou as expectativas do autor, mostrando que um algoritmo bastante simples pode ser extremamente confiÃvel quando se opta pela configuraÃÃo de um conversor por mÃdulo. / The photovoltaic sector has been distinguishing itself from all other renewable energy sources, due to its large growth through the last years. For this reason, it has become the third major clean source of power generation worldwide. In Brazil, this sector still doesnât have great pertinence in the energy matrix, given the imported technology of converters and panels. Considering the demand to develop this technology, this paper propounds the research and implementation of a high gain DC/ DC converter applied to photovoltaic systems, which aims mainly to remove energy from a photovoltaic module and inject it into a DC constant bus. A photovoltaic module is connected to the input of the high gain converter, with an output voltage equals to 17 Vdc. This converter raises its input voltage and injects its output current at a constant 311 Vdc bus, using the maximum power point tracking (MPPT). The laboratory implemented prototype was designed for a rated power of 100W and it doesnât have electrolytic capacitors, thereby increasing the lifetime of the converter and also allowing the incorporation the converter to the photovoltaic module. The prototype had a strong and low cost performance, necessary characteristics for a converter applied to renewable energy sources. The prototype performance exceeded the authorâs expectations, in relation to the maximum power point tracking. Thus, a quite simple algorithm can be extremely reliable when choosing to configure a converter through a module.
4

Projeto de um conversor CC-CA trifÃsico para interligar um sistema fotovoltaico à rede elÃtrica / Design of a three-phase DC-AC converter to connect a PV system to the electricity grid

Saulo Castro Ximenes 14 December 2012 (has links)
CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / Universidade Federal do Cearà / Atualmente, existem no mercado internacional vÃrios fabricantes de conversores estÃticos para infraestrutura fotovoltaica. No Brasil, por praticamente nÃo existir um produto com tecnologia nacional que atinja este nicho de mercado, à importante e urgente o desenvolvimento de tecnologia nacional na Ãrea de conversores para sistemas fotovoltaicos. O presente trabalho consiste no desenvolvimento de um conversor CC-CA trifÃsico com a finalidade de interligar um sistema fotovoltaico com a rede elÃtrica, onde o objetivo principal deste sistema à fornecer potÃncia ativa para o sistema elÃtrico trifÃsico. Este conversor CC-CA trifÃsico à composto por um estÃgio de conversÃo CC-CC, o qual consiste em um conversor do tipo elevador (Boost), e um estÃgio de conversÃo CC-CA. A escolha da topologia do conversor considerou alguns critÃrios, tais como baixo custo de aquisiÃÃo e de manutenÃÃo, baixa complexidade e elevado grau de compactaÃÃo e de confiabilidade. A modelagem e o controle do conversor sÃo feitos vetorialmente, ou seja, utilizando as transformadas dq0 direta e inversa. Este controle foi implementado em um controlador digital sinais (DSC) da famÃlia dsPIC. O projeto dos controladores de ambos os estÃgios foi feito de forma digital. Por meio da simulaÃÃo foi validado o funcionamento do conversor e de seus controladores projetados. Para a realizaÃÃo dos testes experimentais algumas modificaÃÃes de projeto tiveram que ser efetuadas, pois se verificou uma quantidade significativa de interferÃncia eletromagnÃtica e ruÃdos gerados pelo protÃtipo durante o seu funcionamento. Dentro das condiÃÃes estabelecidas foi possÃvel injetar na rede elÃtrica uma potÃncia em torno de 40% do valor mÃximo especificado. Os resultados experimentais obtidos a partir do protÃtipo montado em laboratÃrio validaram o algoritmo de controle implementado no conversor, sendo injetadas na rede elÃtrica correntes senoidais com baixo conteÃdo harmÃnico e na frequÃncia do sistema elÃtrico brasileiro. / Currently, there are several manufacturers in the international market of static converters for photovoltaic infrastructure. In Brazil, by there is no product with a national technology to reach this niche market, is important and urgent to develop national technology in the field of DC-AC converters to PV systems. The present work consists of developing of a three-phase AC-DC converter with the purpose of connect a PV system to the electricity grid, where the main objective of this system is to provide active power for the three-phase electrical system. This three-phase AC-DC converter is composed of a stage of DC-DC conversion, which consists in a boost converter, and a stage of DC-AC conversion. The choice of converter topology considered some criteria, such as low cost of acquisition and maintenance, low complexity, high compaction and reliability. The modeling and control of the converter are made using the concept of space vector, in the other words, using the dq0 transform direct and inverse. This control was performed in a digital signal controller (DSC) of dsPIC family. The design of the controllers of both stages was done digitally. Through simulation was validated the operation of the converter and its controllers designed. For the experimental tests some design changes had to be made because there was a significant amount of electromagnetic interference and noise generated by the prototype during its operation. From the conditions established was possible to inject into the electricity grid a just over 40% of the maximum value of power specified. The experimental results from the prototype validated the control algorithm implemented in the converter, being injected into the electricity grid sinusoidal currents with low harmonic content and frequency of the brazilian electrical system.
5

Inversor MultinÃvel HÃbrido SimÃtrico TrifÃsico de Cinco NÃveis Baseado na Topologias Half-Bridge/ANPC / FIVE LEVEL THREE PHASE SYMMETRICAL HYBRID MULTILEVEL INVERTER BASED ON A HALF-BRIDGE/ANPC TOPOLOGY

Ranoyca Nayana Alencar LeÃo e Silva 22 February 2013 (has links)
CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / Este trabalho apresenta uma topologia de inversor multinÃvel hÃbrido simÃtrico trifÃsico de cinco nÃveis, concebido a partir das estruturas meia ponte e inversor com grampeamento ativo do neutro, adequado para aplicaÃÃes com alta tensÃo e alta potÃncia. SÃo apresentados os possÃveis estados de comutaÃÃo, lÃgica de acionamento, cÃlculo dos esforÃos nos semicondutores, assim como um estudo de perdas. Duas estratÃgias de modulaÃÃo sÃo selecionadas possibilitando a operaÃÃo concomitante de metade dos interruptores em baixa frequÃncia (60 Hz) e a outra em alta frequÃncia (1020 Hz), reduzindo o nÃmero de comutaÃÃes, consequentemente as perdas nos semicondutores e o conteÃdo harmÃnico da tensÃo de saÃda. Para validar a proposta, foi desenvolvido um protÃtipo com potÃncia de 7,5 kVA e tensÃo de saÃda eficaz de linha 380 V. AlÃm disso, à apresentada a implementaÃÃo de ambas as modulaÃÃes no dispositivo lÃgico programÃvel escolhido, FPGA. Os resultados experimentais da estrutura trifÃsica validam a topologia proposta. A estrutura, operando com a modulaÃÃo baseada na PD-PWM, apresentou DHT de 29,71% e WTHD de 1,93%, enquanto que a baseada na CSV-PWM apresentou DHT de 38,45% e WTHD de 7,21%. AlÃm disso, o rendimento da estrutura proposta à superior se comparado ao da topologia Half-Bridge/NPC, conforme esperado em funÃÃo das perdas na estrutura Half-Bridge/NPC serem maiores e mal distribuÃdas. / This work presents a new topology of a hybrid five-level inverter, conceived from the halfbridge and active neutral point clamped structures, suitable for high-voltage, high-power applications. The possible commutation stages, the switching drive logic, the semiconductors stresses mathematical analysis, and the losses study are presented. Two modulation techniques were selected in order to allow low-frequency (60 Hz) switches operate together with high-frequency switches (1020 Hz), reducing the number of commutations and, consequently, the overall losses and the output voltage total harmonic distortion. In order to validate the proposal, it was developed a 7.5 kVA prototype and AC line output voltage of 380 V. The digital implementation from both modulation techniques on the chosen programmable logic device FPGA is also presented. The experimental results relative to the three-phase structure validate the proposed topology. The topology, operating with the modulation based on Sinusoidal In-Phase Disposition - PWM, presented a THD of 29.71%, and WTHD of 1.93%, while the one based on the Centered Space Vector - PWM presented a THD of 38.45%, and a WTHD of 7.21%. Besides, the overall efficiency is superior when compared to the Half-Bridge/NPC topology, as expected, due to the fact that losses on this structure are higher and misdistributed.
6

Estudo teÃrico: UPQC-UPS monofÃsica com possibilidade de filtragem ativa utilizando a teoria p-q / Single phase UPQC-UPS with active filtering capabilities by using p-q theory

Dante Victor Shimoda Pereira 13 June 2013 (has links)
Conselho Nacional de Desenvolvimento CientÃfico e TecnolÃgico / Este trabalho propÃe o projeto de uma UPQC-UPS monofÃsica de 1,4 kVA e alta eficiÃncia com capacidade de filtragem ativa atravÃs de dois conversores conectados em sÃrie e em paralelo. Com esta topologia, à possÃvel obter uma elevada eficiÃncia e combinar as vantagens dos tipos de UPS on-line e line-interactive, melhorando, ao mesmo tempo, a qualidade de energia da rede e protegendo as cargas de harmÃnicos e oscilaÃÃes de tensÃo. As referÃncias de compensaÃÃo dos conversores sÃrie e paralelo sÃo gerados utilizando a Teoria p-q, que propÃem um conjunto de definiÃÃes para lidar com sistemas elÃtricos sob condiÃÃes nÃo-senoidais. De acordo com os resultados de simulaÃÃo, foi comprovado que, quando os conversores sÃrie e paralelo estÃo em funcionamento, a corrente de entrada do sistema possui baixa taxa de distorÃÃo harmÃnica (TDHi) e o sistema apresenta um fator de potÃncia elevado, mesmo para cargas nÃo-lineares. AlÃm disso, à fornecida à carga uma tensÃo senoidal com baixa taxa de distorÃÃo harmÃnica (TDHv) e com valor eficaz fixo mesmo com oscilaÃÃes na tensÃo de entrada, tanto no modo rede como no modo bateria. SimulaÃÃes foram desenvolvidas no software PSCAD/EMTDC. / This work proposes the design of an UPQC-UPS high efficiency single phase 1.4 kVA with active filter capabilities throughout the parallel and series converters. With this topology, it is possible to obtain high efficiency and combine the advantages of both on-line and line interactive UPS systems improving, at the same time, the grid energy quality. The series/parallel compensation references were generated using the p-q Theory which defines a joint of power definitions to deal with electric systems under non-sinusoidal conditions. According to the simulation results, it was shown that the system input current has a low total harmonic distortion (THDi) and it presents high power factor. Also, the load voltage has a sinusoidal shape with low total harmonic distortion (THDv), both in its grid and battery mode operation. Such simulations were developed in the software PSCAD/EMTDC.
7

Numerical Study of Optical Bistabilidade in an Acousto Optical Tunable Filter Hybrid / Estudo numÃrico da biestabilidade Ãptica em um filtro acusto Ãptico sintonizÃvel hÃbrido

Francisco Tiago Lima 04 March 2010 (has links)
CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / In this work, we show the initial results of Acousto Optical Tunning Filter in hybrid configuration (HAOTF). This hibrid device have a feedback circuit that connect in SAW can be influence by output in only one mode polarization of the AOTF. Such the croostalk and transmission characteristic of AOTF dependent â output, result in behavior bistable. We analyze the input power by output power in device opering with continuos wave (CW), nonlinear (SPM) and without loss. Obtain the loop of bistability to display the relation between input power and output power considering parameters of AOTF, since: the product among coupling coefficient (κ ) and deviceâs length (ξL ), gain ( G ) and phase mismatching ( ∆β ). / Nesta dissertaÃÃo, apresentamos os resultados de um estudo sobre um AOTF numa configuraÃÃo hÃbrida, caracterizada pela presenÃa de um circuito de realimentaÃÃo. Este circuito de realimentaÃÃo permite que a tensÃo elÃtrica, aplicada ao transdutor (SAW), possa ser influenciada pela potencia de saÃda de uma das polarizaÃÃes do AOTF. Desta forma, a condiÃÃo de casamento de fase (freqÃÃncia de ressonÃncia) e as caracterÃsticas de transmissÃo do AOTF tornam-se dependentes da potencia de saÃda, resultando numa resposta biestÃvel. Inicialmente esta anÃlise consiste em observar a potÃncia do campo incidente pela potÃncia do campo emergente, com o dispositivo operando sob a aÃÃo de uma onda contÃnua no tempo (CW), em regime nÃo linear (SPM) e sem perdas. Neste sentido, obtemos as curvas de biestabilidade, mostrando a relaÃÃo entre as potÃncias de entrada e saÃda, em funÃÃo de diversos parÃmetros do AOTF, como: o produto entre a constante de acoplamento ( κ ) e o comprimento do dispositivo ( ξL ), alÃm do fator de conversÃo potencia - constante de propagaÃÃo de onda ( G ) e do descasamento de fase ( ∆β ).
8

Evaluation of the operation of the HVDC system of Madeira River complex interconnection to the Southern Region of the brazilian electric system / AvaliaÃÃo da operaÃÃo do sistema HVDC de interligaÃÃo do complexo do Rio Madeira à RegiÃo Sul do sistema elÃtrico brasileiro

Josà Dickson AraÃjo de Oliveira 26 October 2015 (has links)
This work proposes a model for the HVDC transmission system of the Madeira River Complex, which is developed using PSCAD/EMTDC and based on the design provided by the Energy Research Company (EPE) during the granting concession stage. The implemented model is evaluated by comparing the simulation results and actual data regarding events that occurred in the National Interconnected System (SIN) involving the complex. The Madeira River HVDC system is rated at 7,100 MW, being responsible for transmitting the power generated by the hydropower plants of Santo AntÃnio and Jirau, which are close to the city of Porto Velho, to local load centers and southeastern Brazil, thus reaching the Araraquara substation in the state of SÃo Paulo through two 2,350 km lines. The system consists of two back-to-back (antiparallel) blocks rated at 400 MW each using capacitor-commutated converter stations in order to supply the load comprising the states of RondÃnia and Acre, and also two bipoles of 3,150 MW each, which are constituted by 12-pulse line-commutated current source converters so that power can be transmitted to southeastern Brazil. The results of comparison between actual data and the simulation tests have shown that the percentage difference between the evaluated quantities are within acceptable limits, while it can be concluded that the proposed model is properly validated. / Este trabalho propÃe um modelo do sistema de transmissÃo HVDC do Complexo do Rio Madeira, desenvolvido no ambiente PSCAD/EMTDC e baseado no projeto disponibilizado pela Empresa de Pesquisa EnergÃtica - EPE na fase de concessÃo das instalaÃÃes. O modelo construÃdo à avaliado por meio da comparaÃÃo entre os resultados de simulaÃÃo e os dados reais de ocorrÃncias no Sistema Interligado Nacional - SIN que envolveram o complexo. O HVDC do Rio Madeira possui capacidade total de conversÃo de 7.100 MW, e transporta a energia gerada nas usinas hidroelÃtricas de Santo AntÃnio e Jirau, prÃximas a Porto Velho, para centros de carga locais e para o sudeste do Brasil, chegando à subestaÃÃo Araraquara, no estado de SÃo Paulo, atravÃs de duas linhas em corrente contÃnua de 2.350 km de extensÃo. O sistema à composto por dois blocos back-to-back (anti-paralelo) de 400 MW cada, com estaÃÃes conversoras comutadas por capacitores, para atender as cargas dos estados de RondÃnia e Acre, e dois elos bipolares de 3.150 MW cada, constituÃdos de conversores fonte de corrente de 12 pulsos com comutaÃÃo natural de linha, para transmissÃo de energia para o sudeste do paÃs. Os resultados da comparaÃÃo entre os dados reais e a simulaÃÃo mostraram que as diferenÃas percentuais entre grandezas avaliadas se mantiveram dentro de limites satisfatÃrios, podendo-se concluir que o modelo construÃdo foi considerado validado.
9

Impact of electric vehicles in the steady state operation of distribution systems / Impacto de veÃculos elÃtricos na operaÃÃo em regime permanente de sistemas de distribuiÃÃo

Erasmo Saraiva de Castro 15 June 2015 (has links)
FundaÃÃo Cearense de Apoio ao Desenvolvimento Cientifico e TecnolÃgico / This work aims to quantify the impact in the steady state operation of a distribution system when electric vehicles are connected. It is worth noting that the connection of them may cause significant changes in the voltage profile, in the degree of voltage unbalance and in the electrical losses of the system. In order to make this analysis, a three-phase power flow program was developed in MATLAB language. This program is based on the Ladder Iterative Technique and it contains models of overhead distribution lines, underground distribution lines, spot loads, distributed loads connected in wye and delta, step voltage regulators, capacitor banks, three-phase transformers and the model of an electric vehicle. This model allows simulation of a real electric vehicle of model Tesla Roadster, produced by Tesla Motors. The test system used in all simulations was the IEEE 13 bus. Moreover, the methodology consisted in simulate the system with the voltage regulator and without the voltage regulator under heavy load and light load conditions. The electric vehicle was connected to a specific systemâs bus and it were considered that it could work as a load or as a distributed generator with or without positive sequence voltage control. Constants configurations of the electric vehicles were considered for the heavy load and light load cases. The results of the simulations reveal there was voltage violation due to the connection of electric vehicles acting as loads in the test system under heavy load conditions without voltage regulator. When they operate as generators, they can maintain the voltage unbalance under the allowed 2%, turning the systemâs voltages more balanced. There were significant reductions when the electric vehicles acted as a load (71.1%) and as generator (77.5%) on the total real power losses when the system operated with voltage regulator on the substation and the electric vehicles operated with positive sequence voltage control (specified at 1,0 pu). / Este trabalho tem o objetivo de quantificar o impacto da conexÃo de veÃculos elÃtricos na operaÃÃo em regime permanente de um sistema de distribuiÃÃo. à visto que a conexÃo dos mesmos pode causar mudanÃas significativas no perfil de tensÃes, no grau de desequilÃbrio de tensÃo e nas perdas elÃtricas do sistema. Para realizar essa anÃlise, desenvolveu-se um programa de fluxo de potÃncia trifÃsico na linguagem MATLAB. O programa à baseado na tÃcnica iterativa de escada. Foram implementados nesse programa modelos de linhas de distribuiÃÃo aÃreas e subterrÃneas, modelos de cargas concentradas e distribuÃdas conectadas em delta e em estrela, modelos de reguladores de tensÃo, modelos de banco de capacitores, modelo de transformadores trifÃsicos e o modelo do veÃculo elÃtrico. Esse modelo permite simular o veÃculo elÃtrico Tesla Roadster da Tesla Motors. O sistema teste utilizado em todas as simulaÃÃes foi o sistema IEEE 13 barras. A metodologia utilizada consistiu em simular o sistema sem regulador de tensÃo e com o regulador de tensÃo, em carga pesada e em carga leve. O veÃculo elÃtrico foi conectado a uma barra do sistema e considerou-se que o mesmo podia funcionar como carga ou gerador distribuÃdo sem e com controle de tensÃo de sequÃncia positiva no ponto de conexÃo. Adotou-se disposiÃÃes constantes de veÃculos elÃtricos para os casos de carga pesada e carga leve. Os resultados das simulaÃÃes revelam que houve violaÃÃo de tensÃo devido à inserÃÃo de veÃculos elÃtricos atuando como carga no sistema teste em carga pesada sem regulador de tensÃo. Jà quando operam como gerador, os veÃculos elÃtricos diminuem o grau de desequilÃbrio em mÃdia, podendo mantÃ-lo abaixo do limite permitido de 2 %, tornando assim as tensÃes das barras trifÃsicas do sistema mais equilibradas. Houve reduÃÃes significativas quando os veÃculos elÃtricos atuaram como carga (71,1 %) e como gerador (77,5 %) na perda de potÃncia ativa total do sistema quando o sistema operou com regulador de tensÃo na subestaÃÃo e os veÃculos elÃtricos operaram com controle de tensÃo de sequÃncia positiva (especificada em 1,0 pu).
10

AnÃlise e Projeto de um Conversor NPC Para InterligaÃÃo de Sistemas de ConversÃo de Energia à Rede ElÃtrica / Analyse and design of a NPC converter for grid-connected energy conversion systems

Cicero Alisson dos Santos 24 October 2011 (has links)
Neste tabalho à realizado o estudo de um conversor de trÃs nÃveis com ponto neutro grampeado (NPC), proposto para a interligaÃÃo de sistemas de conversÃo de energia à rede elÃtrica. Para tanto à utilizado um filtro indutivo L, tÃcnicas de controle vetorial, e a tÃcnica PLLcomo mÃtodo de sincronismo. SÃo desenvolvidas equaÃÃes para a determinaÃÃo das perdas do conversor, as quais podem ser aplicadas a diversas tÃcnicas de modulaÃÃo PWM. TrÃs tÃcnicas sÃo apresentadas: modulaÃÃo PD; modulaÃÃo com injeÃÃo de terceiro harmÃnico (THIPWM); e modulaÃÃo vetorial baseada em portadora (CB-SVPWM). Toda a modelagem do sistema à apresentada, bem como um exemplo de projeto para um sistema de 6 kW.SÃo realizadas simulaÃÃes computacionaispara diferentes estudos de caso, validando o projeto do conversor e a modelagem desenvolvida. A resposta Ãs dinÃmicas do sistema à satisfatÃria, sendo o conversor capaz de controlar o fluxo de potÃncia ativa (com fator de potÃncia uniÃrio) e reativa entregues à rede. / This work deals with the study of a three-level inverter with Neutral Point Clamped (NPC), proposed for the interconnection of energy conversion systems to the grid. In order to accomplish a complete study, an inductive filter L is proposed, as well as vector control techniques and a PLL synchronization method. Equations are developed for the determination of the losses of the converter, which can be applied to various PWM techniques. Three Modulation techniques are presented: Phase Disposition modulation(PD), modulation with injection of the third harmonic (THIPWM) and carrier-based space vector modulation (SVPWM-CB). The complete modeling system is presented, as well as an example for designing a system of 6 kW. Numerical simulations are performed for different study cases, validating the converter design and modeling developed. The simulation results show that the proposed NPC converter is fully satisfactory, the converter being able to control the active (unity power factor) and reactive power flow delivered to the grid.

Page generated in 0.0304 seconds